{"id":92236,"date":"2026-04-20T07:33:02","date_gmt":"2026-04-20T07:33:02","guid":{"rendered":"https:\/\/discover.restek.com\/?p=92236"},"modified":"2026-06-03T02:35:55","modified_gmt":"2026-06-03T02:35:55","slug":"cashew-nut-allergen-test-lc-msms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/cashew-nut-allergen-test-lc-msms\/","title":{"rendered":"\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u30a2\u30ec\u30eb\u30b2\u30f3\u8868\u793a\u7fa9\u52d9\u5316 \u5bfe\u5fdc\u30ac\u30a4\u30c9"},"content":{"rendered":"<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     NAVIGATION\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<nav style=\"box-sizing: border-box; margin: 0; position: sticky; top: 0; z-index: 100; background: #ffffff; padding: 0 2rem; display: flex; align-items: center; justify-content: space-between; height: 56px; box-shadow: 0 2px 8px rgba(0,0,0,0.00);\" aria-label=\"\u30b5\u30a4\u30c8\u30ca\u30d3\u30b2\u30fc\u30b7\u30e7\u30f3\">\n<div style=\"box-sizing: border-box; margin: 0; padding: 0;\"><\/div>\n<div class=\"nav-badge\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.0rem; font-weight: bold; background: #0080C3; color: white; padding: 4px 12px; border-radius: 2px; letter-spacing: 0.05em; text-transform: uppercase;\">\u30a2\u30ec\u30eb\u30b2\u30f3\u5206\u6790 \u7279\u96c6<\/div>\n<\/nav>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     HERO\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<header class=\"hero\" style=\"box-sizing: border-box; margin: 0; background: #001F3F; position: relative; overflow: hidden; padding: 5rem 2rem 4.5rem; min-height: 500px; display: flex; align-items: center;\" role=\"banner\">\n<div class=\"hero-content\" style=\"box-sizing: border-box; padding: 0; position: relative; z-index: 1; max-width: 900px; margin: 0 auto; width: 100%;\">\n<div class=\"hero-eyebrow\" style=\"box-sizing: border-box; margin: 0; display: inline-flex; align-items: center; gap: 8px; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.2rem; color: #0080c3; letter-spacing: 0.15em; text-transform: uppercase; margin-bottom: 1rem; border: 1px solid rgba(0,128,195,0.35); padding: 4px 12px; border-radius: 2px; background: rgba(0,128,195,0.08);\">2026\u5e744\u67081\u65e5 \u516c\u5b9a\u691c\u67fb\u6cd5 \u65bd\u884c<\/div>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: clamp(1.6rem, 4vw, 3rem); font-weight: 900; color: #ffffff; line-height: 1.2; margin-bottom: 1.2rem;\" role=\"heading\" aria-level=\"1\">\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4<br \/>\n<em style=\"box-sizing: border-box; margin: 0; padding: 0; font-style: normal; color: #0080c3;\">\u30a2\u30ec\u30eb\u30b2\u30f3\u8868\u793a\u7fa9\u52d9\u5316 \u5bfe\u5fdc\u30ac\u30a4\u30c9<\/em><br \/>\n\u7279\u5b9a\u539f\u6599\u8ffd\u52a0\u3068LC-MS\/MS\u516c\u5b9a\u691c\u67fb\u6cd5<\/div>\n<p class=\"hero-sub\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 1rem; color: rgba(255,255,255,0.65); max-width: 900px; line-height: 1.8; margin-bottom: 1rem;\">\u6d88\u8cbb\u8005\u5e81\u304c2026\u5e744\u67081\u65e5\u4ed8\u3067\u516c\u8868\u3057\u305f\u516c\u5b9a\u691c\u67fb\u6cd5\u306b\u304a\u3044\u3066\u3001LC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\uff08NH\u6cd5\uff09\u306e\u516c\u5b9a\u6cd5\u8a18\u8f09\u30ab\u30e9\u30e0\u3068\u3057\u3066 <strong style=\"box-sizing: border-box; margin: 0; padding: 0; color: white;\">Raptor Inert ARC-18<\/strong> \u304c\u6b63\u5f0f\u306b\u660e\u8a18\u3055\u308c\u307e\u3057\u305f\u3002\u79d1\u5b66\u7684\u6839\u62e0\u306b\u57fa\u3065\u304d\u30013\u3064\u306e\u516c\u5b9a\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n<div class=\"hero-cta-group\" style=\"box-sizing: border-box; margin: 0; padding: 0; display: flex; gap: 1rem; flex-wrap: wrap;\"><a class=\"btn-primary\" style=\"box-sizing: border-box; margin: 0; display: inline-flex; align-items: center; gap: 8px; background: #0080C3; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.88rem; padding: 12px 24px; border-radius: 2px; text-decoration: none; transition: all 0.2s ease; letter-spacing: 0.03em;\" href=\"#methods\"> 3\u6cd5\u3092\u6bd4\u8f03\u3059\u308b \u2192 <\/a> <a class=\"btn-outline\" style=\"box-sizing: border-box; margin: 0; display: inline-flex; align-items: center; gap: 8px; background: transparent; color: rgba(255,255,255,0.8); font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: 500; font-size: 0.88rem; padding: 12px 24px; border-radius: 2px; text-decoration: none; border: 1.5px solid rgba(255,255,255,0.3); transition: all 0.2s ease;\" href=\"#product\"> Raptor Inert ARC-18 <\/a> <a class=\"btn-outline\" style=\"box-sizing: border-box; margin: 0; display: inline-flex; align-items: center; gap: 8px; background: transparent; color: rgba(255,255,255,0.8); font-family: &#039;Myriad Pro&#039;, &#039;Helvetica Neue&#039;, Helvetica, Arial, &#039;Noto Sans JP&#039;, sans-serif; font-weight: 500; font-size: 0.88rem; padding: 12px 24px; border-radius: 2px; text-decoration: none; border: 1.5px solid rgba(255,255,255,0.3); transition: all 0.2s ease;\" href=\"https:\/\/explore.restek.com\/jp_cashew-nut-allergen-test?utm_source=discover_restek_jp&amp;utm_medium=internal_cta&amp;utm_campaign=cashew_allergen_article&amp;utm_id=jpn_cashew_allergen_202606&amp;utm_content=document_download\" target=\"_blank\" rel=\"noopener\"> PDF\u7248\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9 <\/a><\/div>\n<\/div>\n<\/header>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     CONFIRMED BANNER\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<div class=\"confirmed-banner\" style=\"box-sizing: border-box; margin: 0; background: linear-gradient(135deg, #E8F5E9, #F1F8E9); border-left: 4px solid #0D7A3E; padding: 1rem 2rem;\" role=\"status\" aria-live=\"polite\">\n<div class=\"confirmed-inner\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto; display: flex; gap: 1rem; align-items: flex-start;\">\n<div class=\"confirmed-icon\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 1.3rem; flex-shrink: 0; margin-top: 2px;\">\u2705<\/div>\n<div class=\"confirmed-text\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 1.0rem; color: #1b4332; line-height: 1.6;\"><strong style=\"box-sizing: border-box; margin: 0; padding: 0; color: #0d7a3e;\">\u3010\u516c\u5b9a\u691c\u67fb\u6cd5 \u516c\u8868\u6e08\u307f\u3011<\/strong><br \/>\n\u6d88\u8cbb\u8005\u5e81\u306f2026\u5e744\u67081\u65e5\u4ed8\u3067\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u3092\u6700\u7d42\u6539\u6b63\u30fb\u516c\u8868\u3057\u307e\u3057\u305f\u3002<br \/>\n\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u306f\u7279\u5b9a\u539f\u6750\u65999\u54c1\u76ee\u76ee\u306b\u8ffd\u52a0\u3055\u308c\u3001LC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\uff08NH\u6cd5\uff09\u306b<br \/>\n<strong style=\"box-sizing: border-box; margin: 0; padding: 0; color: #0d7a3e;\">Raptor Inert ARC-18\uff08Restek\u793e\u88fd\uff09<\/strong>\u304c\u516c\u5b9a\u6cd5\u8a18\u8f09\u30ab\u30e9\u30e0\u3068\u3057\u3066\u660e\u8a18\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n<a style=\"box-sizing: border-box; margin: 0; padding: 0; color: #0d7a3e;\" href=\"https:\/\/www.caa.go.jp\" target=\"_blank\" rel=\"noopener\">\u6d88\u8cbb\u8005\u5e81\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8\u3067\u78ba\u8a8d<\/a><\/div>\n<\/div>\n<\/div>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     STATS\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<div class=\"stats-section\" style=\"box-sizing: border-box; margin: 0; background: #001F3F; padding: 2.5rem 2rem;\" aria-label=\"\u4e3b\u8981\u30c7\u30fc\u30bf\">\n<div class=\"stats-grid\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto; display: grid; grid-template-columns: repeat(auto-fit, minmax(160px, 1fr)); border: 1px solid rgba(255,255,255,0.1); border-radius: 4px; overflow: hidden;\">\n<div class=\"stat-item\" style=\"box-sizing: border-box; margin: 0; padding: 1.6rem 1.2rem; background: rgba(255,255,255,0.03); border-right: 1px solid rgba(255,255,255,0.07); transition: background 0.2s;\">\n<div class=\"stat-number\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.9rem; font-weight: 900; color: #0080c3; line-height: 1; margin-bottom: 0.4rem;\">9\u54c1\u76ee<\/div>\n<div class=\"stat-label\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: rgba(255,255,255,0.5); line-height: 1.4;\">\u7279\u5b9a\u539f\u6750\u6599<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\uff08\u7fa9\u52d9\u8868\u793a\uff09\u306e\u6570<\/div>\n<div class=\"stat-cite\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.62rem; color: rgba(255,255,255,0.3); margin-top: 0.3rem;\">\u51fa\u5178\uff1a[1]<\/div>\n<\/div>\n<div class=\"stat-item\" style=\"box-sizing: border-box; margin: 0; padding: 1.6rem 1.2rem; background: rgba(255,255,255,0.03); border-right: 1px solid rgba(255,255,255,0.07); transition: background 0.2s;\">\n<div class=\"stat-number\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.9rem; font-weight: 900; color: #0080c3; line-height: 1; margin-bottom: 0.4rem;\">10 \u00b5g\/g<\/div>\n<div class=\"stat-label\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: rgba(255,255,255,0.5); line-height: 1.4;\">\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u967d\u6027\u5224\u5b9a\u95be\u5024<\/div>\n<div class=\"stat-cite\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.62rem; color: rgba(255,255,255,0.3); margin-top: 0.3rem;\">\u51fa\u5178\uff1a[1]<\/div>\n<\/div>\n<div class=\"stat-item\" style=\"box-sizing: border-box; margin: 0; padding: 1.6rem 1.2rem; background: rgba(255,255,255,0.03); border-right: 1px solid rgba(255,255,255,0.07); transition: background 0.2s;\">\n<div class=\"stat-number\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.9rem; font-weight: 900; color: #0080c3; line-height: 1; margin-bottom: 0.4rem;\">69%<\/div>\n<div class=\"stat-label\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: rgba(255,255,255,0.5); line-height: 1.4;\">\u30ab\u30b7\u30e5\u30fc\/\u30d4\u30b9\u30bf\u30c1\u30aa<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u4e3b\u8981\u30a2\u30ec\u30eb\u30b2\u30f3\u914d\u5217\u4e00\u81f4\u7387<\/div>\n<div class=\"stat-cite\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.62rem; color: rgba(255,255,255,0.3); margin-top: 0.3rem;\">\u51fa\u5178\uff1a[3]<\/div>\n<\/div>\n<div class=\"stat-item\" style=\"box-sizing: border-box; margin: 0; padding: 1.6rem 1.2rem; background: rgba(255,255,255,0.03); border-right: 1px solid rgba(255,255,255,0.07); transition: background 0.2s;\">\n<div class=\"stat-number\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.9rem; font-weight: 900; color: #0080c3; line-height: 1; margin-bottom: 0.4rem;\">3\u6cd5<\/div>\n<div class=\"stat-label\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: rgba(255,255,255,0.5); line-height: 1.4;\">\u516c\u5b9aLC-MS\/MS<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u78ba\u8a8d\u8a66\u9a13\u6cd5\u306e\u6570<\/div>\n<div class=\"stat-cite\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.62rem; color: rgba(255,255,255,0.3); margin-top: 0.3rem;\">\u51fa\u5178\uff1a[1]<\/div>\n<\/div>\n<div class=\"stat-item\" style=\"box-sizing: border-box; margin: 0; padding: 1.6rem 1.2rem; background: rgba(255,255,255,0.03); transition: background 0.2s; border-right: none;\">\n<div class=\"stat-number\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.9rem; font-weight: 900; color: #0080c3; line-height: 1; margin-bottom: 0.4rem;\">2\u5e74\u9593<\/div>\n<div class=\"stat-label\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: rgba(255,255,255,0.5); line-height: 1.4;\">\u7d4c\u904e\u63aa\u7f6e\u671f\u9593<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u301c2028\u5e743\u670831\u65e5<\/div>\n<div class=\"stat-cite\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.62rem; color: rgba(255,255,255,0.3); margin-top: 0.3rem;\">\u51fa\u5178\uff1a[1]<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     TIMELINE\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<section style=\"box-sizing: border-box; margin: 0; padding: 4rem 2rem;\" aria-labelledby=\"timeline-title\">\n<div class=\"container\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto;\">\n<div class=\"section-eyebrow\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; color: #0080c3; letter-spacing: 0.1em; text-transform: uppercase; margin-bottom: 0.5rem; font-weight: bold;\">\u898f\u5236\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb<\/div>\n<h2 id=\"timeline-title\" class=\"section-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: clamp(1.4rem, 3vw, 2rem); font-weight: 900; color: #000000; line-height: 1.3; margin-bottom: 1rem;\">\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4 \u30a2\u30ec\u30eb\u30ae\u30fc\u8868\u793a\u7fa9\u52d9\u5316\u306e\u7d4c\u7def<\/h2>\n<ul class=\"timeline\" style=\"box-sizing: border-box; margin: 0; padding: 0; list-style: none; position: relative;\" role=\"list\">\n<li class=\"timeline-item\" style=\"box-sizing: border-box; margin: 0; padding: 0; display: flex; gap: 1.5rem; margin-bottom: 2rem;\"><span class=\"tl-date\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.7rem; font-weight: bold; color: #0080c3; width: 76px; flex-shrink: 0; padding-top: 0.2rem; text-align: right; line-height: 1.3;\">2025\u5e74<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>1\u6708<\/span>\n<div class=\"tl-dot done\" style=\"box-sizing: border-box; margin: 0; padding: 0; width: 14px; height: 14px; border-radius: 50%; border: 3px solid white; flex-shrink: 0; margin-top: 0.25rem; z-index: 1; background: #0D7A3E; box-shadow: 0 0 0 2px #0D7A3E;\"><\/div>\n<div class=\"tl-body\" style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<div class=\"tl-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-weight: bold; font-size: 0.95rem; color: #000000; margin-bottom: 0.3rem;\">\u7b2c7\u56de\u30a2\u30c9\u30d0\u30a4\u30b6\u30fc\u4f1a\u8b70 \u2014 \u7fa9\u52d9\u5316\u65b9\u91dd\u306e\u6c7a\u5b9a<span class=\"tl-badge\" style=\"box-sizing: border-box; margin: 0; display: inline-block; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.62rem; font-weight: bold; padding: 2px 8px; border-radius: 2px; margin-left: 6px; background: #0D7A3E; color: white; vertical-align: middle; letter-spacing: 0.05em;\">\u5b8c\u4e86<\/span><\/div>\n<div class=\"tl-desc\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.9rem; color: #3a4454; line-height: 1.65;\">\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3092\u300c\u7279\u5b9a\u539f\u6750\u6599\u306b\u6e96\u305a\u308b\u3082\u306e\u300d\u304b\u3089\u300c\u7279\u5b9a\u539f\u6750\u6599\u300d\uff08\u7fa9\u52d9\u8868\u793a\uff09\u3078\u79fb\u884c\u3059\u308b\u65b9\u91dd\u3092\u767a\u8868\u3002\u30d4\u30b9\u30bf\u30c1\u30aa\u306e\u63a8\u5968\u8868\u793a\u54c1\u76ee\u8ffd\u52a0\u3082\u6c7a\u5b9a\u3002\u516c\u5b9a\u691c\u67fb\u6cd5\u78ba\u7acb\u3092\u6761\u4ef6\u3068\u3057\u305f\u3002<\/div>\n<\/div>\n<\/li>\n<li class=\"timeline-item\" style=\"box-sizing: border-box; margin: 0; padding: 0; display: flex; gap: 1.5rem; margin-bottom: 2rem;\"><span class=\"tl-date\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.7rem; font-weight: bold; color: #0080c3; width: 76px; flex-shrink: 0; padding-top: 0.2rem; text-align: right; line-height: 1.3;\">2025\u5e74<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>12\u6708<\/span>\n<div class=\"tl-dot done\" style=\"box-sizing: border-box; margin: 0; padding: 0; width: 14px; height: 14px; border-radius: 50%; border: 3px solid white; flex-shrink: 0; margin-top: 0.25rem; z-index: 1; background: #0D7A3E; box-shadow: 0 0 0 2px #0D7A3E;\"><\/div>\n<div class=\"tl-body\" style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<div class=\"tl-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-weight: bold; font-size: 0.95rem; color: #000000; margin-bottom: 0.3rem;\">\u7b2c8\u56de\u30a2\u30c9\u30d0\u30a4\u30b6\u30fc\u4f1a\u8b70 \u2014 \u691c\u67fb\u6cd5\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u5b8c\u4e86<span class=\"tl-badge\" style=\"box-sizing: border-box; margin: 0; display: inline-block; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.62rem; font-weight: bold; padding: 2px 8px; border-radius: 2px; margin-left: 6px; background: #0D7A3E; color: white; vertical-align: middle; letter-spacing: 0.05em;\">\u5b8c\u4e86<\/span><\/div>\n<div class=\"tl-desc\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.9rem; color: #3a4454; line-height: 1.65;\">ELISA\u6cd5\u30fb\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u6cd5\u30fbPCR-\u6838\u9178\u30af\u30ed\u30de\u30c8\u6cd5\u30fbLC-MS\/MS\u6cd5\u306e\u5168\u691c\u67fb\u6cd5\u306b\u3064\u3044\u3066\u3001\u56fd\u518510\u301c17\u6a5f\u95a2\u306b\u3088\u308b\u8a66\u9a13\u5ba4\u9593\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u304c\u5b8c\u4e86\u3002\u6b21\u9577\u901a\u77e5\u57fa\u6e96\u3092\u6e80\u305f\u3059\u3053\u3068\u3092\u78ba\u8a8d\u3002\u98df\u54c1\u8868\u793a\u57fa\u6e96\u6539\u6b63\u6848\u3092\u78ba\u5b9a\u3002<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><small style=\"box-sizing: border-box; margin: 0; padding: 0; color: #6b7a8d;\">\u51fa\u5178\uff1a[2]<\/small><\/div>\n<\/div>\n<\/li>\n<li class=\"timeline-item\" style=\"box-sizing: border-box; margin: 0; padding: 0; display: flex; gap: 1.5rem; margin-bottom: 2rem;\"><span class=\"tl-date\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.7rem; font-weight: bold; color: #0080c3; width: 76px; flex-shrink: 0; padding-top: 0.2rem; text-align: right; line-height: 1.3;\">2026\u5e74<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>4\u67081\u65e5<\/span>\n<div class=\"tl-dot done\" style=\"box-sizing: border-box; margin: 0; padding: 0; width: 14px; height: 14px; border-radius: 50%; border: 3px solid white; flex-shrink: 0; margin-top: 0.25rem; z-index: 1; background: #0D7A3E; box-shadow: 0 0 0 2px #0D7A3E;\"><\/div>\n<div class=\"tl-body\" style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<div class=\"tl-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-weight: bold; font-size: 0.95rem; color: #000000; margin-bottom: 0.3rem;\">\u98df\u54c1\u8868\u793a\u57fa\u6e96\u6539\u6b63\u30fb\u516c\u5b9a\u691c\u67fb\u6cd5 \u516c\u8868<span class=\"tl-badge\" style=\"box-sizing: border-box; margin: 0; display: inline-block; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.62rem; font-weight: bold; padding: 2px 8px; border-radius: 2px; margin-left: 6px; background: #0D7A3E; color: white; vertical-align: middle; letter-spacing: 0.05em;\">\u2713 \u65bd\u884c\u6e08\u307f<\/span><\/div>\n<div class=\"tl-desc\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.9rem; color: #3a4454; line-height: 1.65;\">\u6d88\u8cbb\u8005\u5e81\u304c\u98df\u54c1\u8868\u793a\u57fa\u6e96\u3092\u6539\u6b63\u3057\u3001\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3092\u7279\u5b9a\u539f\u6750\u65999\u54c1\u76ee\u76ee\u306b\u8ffd\u52a0\u3002\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u3092\u6700\u7d42\u6539\u6b63\u30fb\u516c\u8868\u3002LC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\uff08NH\u6cd5\uff09\u306bRaptor Inert ARC-18\u304c\u516c\u5b9a\u6cd5\u8a18\u8f09\u30ab\u30e9\u30e0\u3068\u3057\u3066\u660e\u8a18\u3055\u308c\u305f\u3002<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><small style=\"box-sizing: border-box; margin: 0; padding: 0; color: #6b7a8d;\">\u51fa\u5178\uff1a[1]<\/small><\/div>\n<\/div>\n<\/li>\n<li class=\"timeline-item\" style=\"box-sizing: border-box; margin: 0; padding: 0; display: flex; gap: 1.5rem; margin-bottom: 2rem;\"><span class=\"tl-date\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.7rem; font-weight: bold; color: #0080c3; width: 76px; flex-shrink: 0; padding-top: 0.2rem; text-align: right; line-height: 1.3;\">\u516c\u5e03\u5f8c<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>2\u5e74\u4ee5\u5185<\/span>\n<div class=\"tl-dot future\" style=\"box-sizing: border-box; margin: 0; padding: 0; width: 14px; height: 14px; border-radius: 50%; border: 3px solid white; flex-shrink: 0; margin-top: 0.25rem; z-index: 1; background: #D8E2EC; box-shadow: 0 0 0 2px #D8E2EC;\"><\/div>\n<div class=\"tl-body\" style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<div class=\"tl-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-weight: bold; font-size: 0.95rem; color: #000000; margin-bottom: 0.3rem;\">\u7d4c\u904e\u63aa\u7f6e\u7d42\u4e86\uff082028\u5e743\u670831\u65e5\uff09\u2192 \u5b8c\u5168\u65bd\u884c\uff082028\u5e744\u67081\u65e5\uff09<\/div>\n<div class=\"tl-desc\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.9rem; color: #3a4454; line-height: 1.65;\">2028\u5e743\u670831\u65e5\u3092\u3082\u3063\u3066\u7d4c\u904e\u63aa\u7f6e\u671f\u9593\u7d42\u4e86\u30022028\u5e744\u67081\u65e5\u4ee5\u964d\u306b\u88fd\u9020\u30fb\u52a0\u5de5\u30fb\u8f38\u5165\u3055\u308c\u308b\u52a0\u5de5\u98df\u54c1\u306f\u65b0\u8868\u793a\u304c\u7fa9\u52d9\u3002\u9055\u53cd\u306f\u98df\u54c1\u8868\u793a\u6cd5\u9055\u53cd\u3068\u306a\u308b\u3002\uff08\u6839\u62e0\uff1a\u5185\u95a3\u5e9c\u4ee4\u7b2c34\u53f7 \u7b2c2\u6761\uff09<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><small style=\"box-sizing: border-box; margin: 0; padding: 0; color: #6b7a8d;\">\u51fa\u5178\uff1a[1]<\/small><\/div>\n<\/div>\n<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     2-STAGE PROTOCOL\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<section id=\"method\" style=\"box-sizing: border-box; margin: 0; padding: 4rem 2rem; background: #F7F9FB;\" aria-labelledby=\"method-title\">\n<div class=\"container\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto;\">\n<div class=\"section-eyebrow\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; color: #0080c3; letter-spacing: 0.1em; text-transform: uppercase; margin-bottom: 0.5rem; font-weight: bold;\">\u516c\u5b9a\u691c\u67fb\u30d7\u30ed\u30c8\u30b3\u30eb<\/div>\n<h2 id=\"method-title\" class=\"section-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: clamp(1.4rem, 3vw, 2rem); font-weight: 900; color: #000000; line-height: 1.3; margin-bottom: 1rem;\">2\u6bb5\u968e\u691c\u67fb\u30d5\u30ed\u30fc<\/h2>\n<p class=\"section-lead\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.95rem; color: #3a4454; max-width: 680px; line-height: 1.8; margin-bottom: 2.5rem;\">\u6d88\u8cbb\u8005\u5e81\u516c\u5b9a\u691c\u67fb\u6cd5\u306f\u3001\u65e2\u5b58\u306e\u7279\u5b9a\u539f\u6750\u65998\u54c1\u76ee\u3068\u540c\u4e00\u306e2\u6bb5\u968e\u65b9\u5f0f\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002<sup style=\"box-sizing: border-box; margin: 0; padding: 0;\">[1]<\/sup><\/p>\n<div class=\"method-flow\" style=\"box-sizing: border-box; margin: 0; padding: 0; display: grid; grid-template-columns: 1fr auto 1fr; gap: 1rem; align-items: center; margin-bottom: 2.5rem;\">\n<div class=\"method-card\" style=\"box-sizing: border-box; margin: 0; background: #EEF2F6; border-radius: 4px; padding: 1.5rem; border: 1.5px solid #D8E2EC;\"><span class=\"method-tag tag-quant\" style=\"box-sizing: border-box; margin: 0; display: inline-block; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.0 rem; font-weight: bold; padding: 3px 9px; border-radius: 2px; letter-spacing: 0.06em; margin-bottom: 0.6rem; text-transform: uppercase; background: #E8F5E9; color: #0d7a3e;\">\u7b2c1\u6bb5\u968e \uff0f \u5b9a\u91cf\u691c\u67fb\uff08\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\uff09<\/span><\/p>\n<div class=\"method-name\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 1rem; color: #000000; margin-bottom: 0.5rem;\">ELISA\u6cd5<\/div>\n<div class=\"method-desc\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.85rem; color: #3a4454; line-height: 1.65;\">\u6297\u539f\u6297\u4f53\u53cd\u5fdc\u3092\u5229\u7528\u3057\u3001\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u7531\u6765\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u5b9a\u91cf\u7684\u306b\u691c\u51fa\u3002<br \/>\n\u8a66\u9a13\u5ba4\u9593\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\uff0810\u6a5f\u95a2\u4ee5\u4e0a\uff09\u3067\u57fa\u6e96\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u308b\u3002<\/div>\n<div class=\"method-threshold\" style=\"box-sizing: border-box; margin: 0; display: inline-flex; align-items: center; gap: 6px; background: #FFF3CD; border: 1px solid #F59E0B; color: #92400e; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.75rem; padding: 4px 10px; border-radius: 2px; margin-top: 0.8rem;\">10 \u00b5g\/g \u4ee5\u4e0a \u2192 \u78ba\u8a8d\u691c\u67fb\u3078<\/div>\n<\/div>\n<div class=\"method-arrow\" style=\"box-sizing: border-box; margin: 0; padding: 0; text-align: center; font-size: 1.5rem; color: #0080c3; font-weight: 900;\" aria-hidden=\"true\">\u2192<\/div>\n<div class=\"method-card highlight\" style=\"box-sizing: border-box; margin: 0; border-radius: 4px; padding: 1.5rem; border: 1.5px solid #D8E2EC; background: #E0F2FB; border-color: #0080C3;\"><span class=\"method-tag tag-qual\" style=\"box-sizing: border-box; margin: 0; display: inline-block; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1.0rem; font-weight: bold; padding: 3px 9px; border-radius: 2px; letter-spacing: 0.06em; margin-bottom: 0.6rem; text-transform: uppercase; background: #E0F2FB; color: #0080c3;\">\u7b2c2\u6bb5\u968e \uff0f \u5b9a\u6027\u691c\u67fb\uff08\u78ba\u8a8d\uff09<\/span><\/p>\n<div class=\"method-name\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 1rem; color: #000000; margin-bottom: 0.5rem;\">LC-MS\/MS\u6cd5 \uff0f PCR\u6cd5<\/div>\n<div class=\"method-desc\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.85rem; color: #3a4454; line-height: 1.65;\"><strong style=\"box-sizing: border-box; margin: 0; padding: 0;\">LC-MS\/MS\u6cd5\uff08NH\u6cd5\u30fbNS\u6cd5\u30fbHF\u6cd5\uff09<\/strong>\uff1a\u7a2e\u7279\u7570\u7684\u30c8\u30ea\u30d7\u30b7\u30f3\/\u30ad\u30e2\u30c8\u30ea\u30d7\u30b7\u30f3\u6d88\u5316\u30da\u30d7\u30c1\u30c9\u3092\u6a19\u7684\u306bMRM\u691c\u51fa\u3002\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3068\u30d4\u30b9\u30bf\u30c1\u30aa\u3092\u5206\u5b50\u30ec\u30d9\u30eb\u3067\u8b58\u5225\u3002<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><br \/>\n<strong style=\"box-sizing: border-box; margin: 0; padding: 0;\">PCR\u6cd5<\/strong>\uff08\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30fbPCR-\u6838\u9178\u30af\u30ed\u30de\u30c8\uff09\uff1a\u7a2e\u7279\u7570\u7684DNA\u914d\u5217\u3092\u5897\u5e45\u3057\u3066\u691c\u51fa\u3002<\/div>\n<\/div>\n<\/div>\n<p><!-- Cross Reactivity --><\/p>\n<div class=\"cross-react-box\" style=\"box-sizing: border-box; margin: 0; background: #001F3F; border-radius: 4px; padding: 2rem; color: white; margin-top: 2rem;\" aria-labelledby=\"cross-react-title\">\n<div id=\"cross-react-title\" class=\"cr-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 1.0rem; margin-bottom: 1.2rem; color: #0080c3;\">\u306a\u305cLC-MS\/MS\u304c\u78ba\u8a8d\u8a66\u9a13\u6cd5\u306b\u63a1\u7528\u3055\u308c\u305f\u306e\u304b\u3002\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3068\u30d4\u30b9\u30bf\u30c1\u30aa\u306e\u4ea4\u5dee\u53cd\u5fdc\u6027<\/div>\n<div class=\"cr-grid\" style=\"box-sizing: border-box; margin: 0; padding: 0; display: grid; grid-template-columns: 1fr auto 1fr; gap: 1rem; align-items: center; margin-bottom: 1.2rem;\">\n<div class=\"cr-nut\" style=\"box-sizing: border-box; margin: 0; background: rgba(255,255,255,0.06); border-radius: 4px; padding: 1rem; text-align: center;\">\n<div class=\"cr-nut-name\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.95rem; margin-bottom: 0.3rem;\">\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4<\/div>\n<div class=\"cr-nut-sub\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: rgba(255,255,255,0.5); font-style: italic;\">Anacardium occidentale<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u30a6\u30eb\u30b7\u79d1\uff08Anacardiaceae\uff09<\/div>\n<\/div>\n<div class=\"cr-match\" style=\"box-sizing: border-box; margin: 0; padding: 0; text-align: center;\"><span class=\"cr-pct\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 2rem; font-weight: 900; color: #0080c3; display: block; line-height: 1;\">69%<\/span><\/p>\n<div class=\"cr-label\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.7rem; color: rgba(255,255,255,0.5); margin-top: 4px; line-height: 1.4;\">\u4e3b\u8981\u30a2\u30ec\u30eb\u30b2\u30f3\uff082S\u30a2\u30eb\u30d6\u30df\u30f3\uff09<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u30a2\u30df\u30ce\u9178\u914d\u5217\u4e00\u81f4\u7387<\/div>\n<\/div>\n<div class=\"cr-nut\" style=\"box-sizing: border-box; margin: 0; background: rgba(255,255,255,0.06); border-radius: 4px; padding: 1rem; text-align: center;\">\n<div class=\"cr-nut-name\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.95rem; margin-bottom: 0.3rem;\">\u30d4\u30b9\u30bf\u30c1\u30aa<\/div>\n<div class=\"cr-nut-sub\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: rgba(255,255,255,0.5); font-style: italic;\">Pistacia vera<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u30a6\u30eb\u30b7\u79d1\uff08Anacardiaceae\uff09<\/div>\n<\/div>\n<\/div>\n<div class=\"cr-note\" style=\"box-sizing: border-box; margin: 0; padding: 0; border-top: 1px solid rgba(255,255,255,0.1); padding-top: 1rem; font-size: 0.82rem; color: rgba(255,255,255,0.65); line-height: 1.7;\">\u4e21\u8005\u306f\u540c\u3058\u30a6\u30eb\u30b7\u79d1\u306b\u5c5e\u3057\u3001\u4e3b\u8981\u30a2\u30ec\u30eb\u30b2\u30f3\uff082S\u30a2\u30eb\u30d6\u30df\u30f3\uff09\u306e\u30a2\u30df\u30ce\u9178\u914d\u5217\u306b\u7d0469%\u306e\u76f8\u540c\u6027\u304c\u8a8d\u3081\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u9ad8\u3044\u985e\u4f3c\u6027\u3086\u3048\u306b\u3001<strong style=\"box-sizing: border-box; margin: 0; padding: 0; color: rgba(255,255,255,0.9);\">ELISA\u6cd5\uff08\u6297\u539f\u6297\u4f53\u53cd\u5fdc\uff09\u3067\u306f\u6297\u539f\u6297\u4f53\u53cd\u5fdc\u306b\u3088\u308b\u4ea4\u5dee\u53cd\u5fdc\u304c\u8d77\u304d\u3084\u3059\u304f\u3001\u4e21\u8005\u3092\u5b8c\u5168\u306b\u533a\u5225\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3<\/strong>\u3067\u3001\u507d\u967d\u6027\u30ea\u30b9\u30af\u304c\u3042\u308b\u3053\u3068\u77e5\u3089\u308c\u3066\u3044\u307e\u3057\u305f\u3002<br \/>\n\u3053\u308c\u306b\u5bfe\u3057\u3001LC-MS\/MS\u306f\u7a2e\u7279\u7570\u7684\u306a\u30da\u30d7\u30c1\u30c9\u914d\u5217\u3092MRM\u30e2\u30fc\u30c9\u3067\u691c\u51fa\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u5b50\u30ec\u30d9\u30eb\u3067\u306e\u8b58\u5225\u3092\u5b9f\u73fe\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u7a2e\u7279\u6027\u304c\u3001\u672c\u624b\u6cd5\u3092\u78ba\u8a8d\u8a66\u9a13\u3068\u3057\u3066\u63a1\u7528\u3059\u308b\u6280\u8853\u7684\u6839\u62e0\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<br \/>\n<cite class=\"cr-cite\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.7rem; color: rgba(255,255,255,0.35); margin-top: 0.5rem; display: block;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81 \u7b2c7\u56de\u98df\u7269\u30a2\u30ec\u30eb\u30ae\u30fc\u8868\u793a\u30a2\u30c9\u30d0\u30a4\u30b6\u30fc\u4f1a\u8b70\u8cc7\u6599\uff082025\u5e741\u670821\u65e5\uff09[3]<\/cite><\/div>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     3-METHOD COMPARISON\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<section id=\"methods\" class=\"methods-section\" style=\"box-sizing: border-box; margin: 0; padding: 4rem 2rem; background: #F7F9FB;\" aria-labelledby=\"methods-title\">\n<div class=\"container\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto;\">\n<div class=\"section-eyebrow\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; color: #0080c3; letter-spacing: 0.1em; text-transform: uppercase; margin-bottom: 0.5rem; font-weight: bold;\">\u516c\u5b9aLC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5<\/div>\n<h2 id=\"methods-title\" class=\"section-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: clamp(1.4rem, 3vw, 2rem); font-weight: 900; color: #000000; line-height: 1.3; margin-bottom: 1rem;\">3\u3064\u306e\u516c\u5b9a\u6cd5\u30bb\u30c3\u30c8\u306e\u6bd4\u8f03<\/h2>\n<p class=\"section-lead\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.95rem; color: #3a4454; max-width: 900px; line-height: 1.8; margin-bottom: 2.5rem;\">\u6d88\u8cbb\u8005\u5e81\u516c\u5b9a\u691c\u67fb\u6cd5\u3067\u306f\u3001LC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\u3068\u3057\u3066\u72ec\u7acb\u3057\u305f3\u6cd5\u30bb\u30c3\u30c8\u304c\u898f\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n\u5404\u6cd5\u306f\u524d\u51e6\u7406\u30fb\u6e2c\u5b9a\u30fb\u5224\u5b9a\u304c\u4e00\u4f53\u5316\u3057\u305f\u30bb\u30c3\u30c8\u3067\u3042\u308a\u3001\u691c\u67fb\u6a5f\u95a2\u306f\u3044\u305a\u308c\u304b1\u6cd5\u3092\u9078\u629e\u3057\u3066\u5b9f\u65bd\u3057\u307e\u3059\u3002<sup style=\"box-sizing: border-box; margin: 0; padding: 0;\">[1]<\/sup><\/p>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0; overflow-x: auto;\">\n<table class=\"method-compare-table\" style=\"box-sizing: border-box; margin: 0; padding: 0; width: 100%; border-collapse: collapse; font-size: 0.82rem;\" role=\"grid\" width=\"100%\" aria-label=\"3\u6cd5\u6bd4\u8f03\u8868\">\n<thead style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<th style=\"box-sizing: border-box; margin: 0; background: #001F3F; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.75rem 1rem; text-align: left; font-size: 0.78rem; width: 22%;\" align=\"left\" width=\"22%\">\u9805\u76ee<\/th>\n<th class=\"col-nh\" style=\"box-sizing: border-box; margin: 0; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.75rem 1rem; text-align: left; font-size: 0.78rem; background: #003060; width: 26%;\" align=\"left\" width=\"26%\">NH\u6cd5<\/th>\n<th style=\"box-sizing: border-box; margin: 0; background: #001F3F; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.75rem 1rem; text-align: left; font-size: 0.78rem; width: 26%;\" align=\"left\" width=\"26%\">NS\u6cd5<\/th>\n<th style=\"box-sizing: border-box; margin: 0; background: #001F3F; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.75rem 1rem; text-align: left; font-size: 0.78rem; width: 26%;\" align=\"left\" width=\"26%\">HF\u6cd5<\/th>\n<\/tr>\n<\/thead>\n<tbody style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u6b63\u5f0f\u540d\u79f0<\/td>\n<td class=\"col-nh-data\" style=\"box-sizing: border-box; margin: 0; color: #0080c3; font-weight: bold; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u5185\u6a19\u6e96\u975e\u6dfb\u52a0\u30fb<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u30b7\u30b0\u30ca\u30eb\u30ce\u30a4\u30ba\u6bd4\u5224\u5b9a<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">2\u6bb5\u968e\u5185\u6a19\u6e96<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u76f8\u5bfe\u6bd4\u5224\u5b9a<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">1\u6bb5\u968e\u5185\u6a19\u6e96<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u76f8\u5bfe\u6bd4\u5224\u5b9a<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u524d\u51e6\u7406\u6cd5<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">pNH\u6cd5<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">pNS\u6cd5<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">pHF\u6cd5<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u8a66\u6599\u63a1\u53d6\u91cf<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">2 g<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">1 g<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">1 g<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u62bd\u51fa\u6761\u4ef6<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">37\u2103\u30011\u6642\u9593\u632f\u3068\u3046<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\uff08\u5c3f\u7d20\u30fb\u30c1\u30aa\u5c3f\u7d20\u30fbDTT\uff09<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u6cb8\u9a30\u6c34\u6d74\u300110\u5206<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\uff08APEX Reagents\uff09<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u5ba4\u6e29\u3001\u4e00\u6669\u632f\u3068\u3046<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\uff08ExSta\uff1dELISA\u7528\u3068\u540c\u4e00\uff09<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u6d88\u5316\u9175\u7d20<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u30c8\u30ea\u30d7\u30b7\u30f3<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u30c8\u30ea\u30d7\u30b7\u30f3<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u30ad\u30e2\u30c8\u30ea\u30d7\u30b7\u30f3<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u967d\u30a4\u30aa\u30f3\u4ea4\u63db\u306e\u307f<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">C18 + \u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u306b\u3088\u308b\u4e8c\u6bb5\u968e\u7cbe\u88fd<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u967d\u30a4\u30aa\u30f3\u4ea4\u63db + \u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u306b\u3088\u308b\u4e8c\u6bb5\u968e\u7cbe\u88fd<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u516c\u5b9a\u6cd5\u8a18\u8f09\u30ab\u30e9\u30e0<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\"><strong>Raptor Inert ARC-18<\/strong><br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><br \/>\n2.7 \u00b5m, 3.0\u00d7100 mm\uff08Restek\uff09<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u30e1\u30bf\u30eb\u30d5\u30ea\u30fc C18\u30ab\u30e9\u30e03 \u00b5m, 2.1\u00d7100 mm<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u30df\u30c3\u30af\u30b9\u30e2\u30fc\u30c9 C18\u30ab\u30e9\u30e0<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><br \/>\n3 \u00b5m, 3.0\u00d7150 mm<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0<\/td>\n<td class=\"col-nh-data\" style=\"box-sizing: border-box; margin: 0; color: #0080c3; font-weight: bold; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\"><span class=\"badge-no-guard\" style=\"box-sizing: border-box; margin: 0; display: inline-block; background: #D1FAE5; color: #0d7a3e; border: 1px solid #6EE7B7; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.62rem; font-weight: bold; padding: 2px 7px; border-radius: 2px; white-space: nowrap;\">\u8a18\u8f09\u306a\u3057\uff08\u4e0d\u8981\uff09<\/span><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\"><span class=\"badge-guard\" style=\"box-sizing: border-box; margin: 0; display: inline-block; background: #FEF3C7; color: #92400e; border: 1px solid #F59E0B; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.62rem; font-weight: bold; padding: 2px 7px; border-radius: 2px; white-space: nowrap;\">\u8a18\u8f09\u3042\u308a<\/span><br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><br \/>\n<small style=\"box-sizing: border-box; margin: 0; padding: 0;\">\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u30ab\u30e9\u30e0<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>3 \u00b5m, 2.1\u00d710 mm<\/small><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\"><span class=\"badge-no-guard\" style=\"box-sizing: border-box; margin: 0; display: inline-block; background: #D1FAE5; color: #0d7a3e; border: 1px solid #6EE7B7; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.62rem; font-weight: bold; padding: 2px 7px; border-radius: 2px; white-space: nowrap;\">\u8a18\u8f09\u306a\u3057\uff08\u4e0d\u8981\uff09<\/span><\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u6d41\u901f<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">0.4 mL\/min<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">0.3 mL\/min<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">0.3 mL\/min<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u79fb\u52d5\u76f8<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">A: 0.2%\u9162\u9178\u6c34<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>B: 0.2%\u9162\u9178\/ACN<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">A: 0.2%\u9162\u9178\u6c34<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>B: 0.2%\u9162\u9178\/ACN<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">A: 0.1%\u30ae\u9178\u6c34<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>B: 0.1%\u30ae\u9178\/ACN<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u30ab\u30e9\u30e0\u6e29\u5ea6<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">50\u2103<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">50\u2103<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">50\u2103<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u5185\u6a19\u6e96\uff08IS\uff09<\/td>\n<td class=\"col-nh-data\" style=\"box-sizing: border-box; margin: 0; color: #0080c3; font-weight: bold; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\"><strong style=\"box-sizing: border-box; margin: 0; padding: 0;\">\u4e0d\u8981<\/strong><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u5b89\u5b9a\u540c\u4f4d\u4f53\u6a19\u8b58<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u30da\u30d7\u30c1\u30c9\uff082\u7a2e\uff09<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u5b89\u5b9a\u540c\u4f4d\u4f53\u6a19\u8b58<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u30da\u30d7\u30c1\u30c9\uff0b\u5916\u6a19\u6e96<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u967d\u6027\u5224\u5b9a\u57fa\u6e96<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u5168MRM\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\u306e<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><strong style=\"box-sizing: border-box; margin: 0; padding: 0;\">S\/N\u6bd4 \u2265 10<\/strong><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">IS\u5bfe\u6bd4\u9762\u7a4d\u6bd4 \u2265 1\/10<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\uff08\u5404\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\uff09<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5;\" valign=\"top\">\u5916\u6a19\u6e96IS\u5bfe\u6bd4\u9762\u7a4d\u6bd4 \u2265 1\/10<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\uff08\u5404\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\uff09<\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td class=\"row-label\" style=\"box-sizing: border-box; margin: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.78rem; color: #3a4454; white-space: nowrap; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">ELISA\u7528\u62bd\u51fa\u6db2<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u3068\u306e\u5171\u7528<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u4e0d\u53ef\uff08\u5225\u9014\u8abf\u88fd\uff09<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\">\u4e0d\u53ef\uff08\u5225\u9014\u8abf\u88fd\uff09<\/td>\n<td class=\"col-nh-data\" style=\"box-sizing: border-box; margin: 0; color: #0080c3; font-weight: bold; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; vertical-align: top; line-height: 1.5; background: #F7F9FB;\" valign=\"top\"><strong style=\"box-sizing: border-box; margin: 0; padding: 0;\">\u53ef\u80fd<\/strong><br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><small style=\"box-sizing: border-box; margin: 0; padding: 0;\">\uff08ExSta\u3092\u5171\u7528\uff09<\/small><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: #6b7a8d; margin-top: 0.5rem;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 [1]\u3002&#8221;\u53c8\u306f\u540c\u7b49\u306e\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u3082\u306e\u3092\u7528\u3044\u308b&#8221;\u306e\u898f\u5b9a\u306b\u3088\u308a\u3001\u5404\u6cd5\u3068\u3082\u540c\u7b49\u6027\u304c\u8a3c\u660e\u3055\u308c\u305f\u4ee3\u66ff\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u304c\u8a8d\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><!-- \u2460 \u524d\u51e6\u7406\u9078\u629e\u306e\u30a2\u30c9\u30d0\u30a4\u30b9 \u2192 \u9752 --><\/p>\n<div style=\"box-sizing: border-box; border-radius: 4px; padding: 1.2rem 1.5rem; margin: 2rem 0; font-size: 0.88rem; line-height: 1.7; background: #E0F2FB; border-left: 4px solid #0080C3; color: #003060;\" role=\"note\"><strong style=\"font-family: 'Myriad Pro','Helvetica Neue',Helvetica,Arial,sans-serif;\">\u5206\u6790\u6cd5\u9078\u629e\u306e\u30a2\u30c9\u30d0\u30a4\u30b9<\/strong><br \/>\n<strong>\u98df\u54c1\u306e\u52a0\u5de5\u5ea6\u3084\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u9069\u3057\u305f<\/strong>\u524d\u51e6\u7406\u6cd5\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002NH\u6cd5\u306e\u524d\u51e6\u7406\u3067\u3042\u308bpNH\u6cd5\u306f\u5c3f\u7d20\u30fb\u30c1\u30aa\u5c3f\u7d20\u30fbDTT\u3092\u542b\u3080\u5909\u6027\u5264\u306b\u3088\u308b\u5316\u5b66\u7684\u62bd\u51fa\u304c\u7279\u5fb4\u3067\u3001\u305f\u3093\u3071\u304f\u8cea\u304c\u51dd\u96c6\u30fb\u5909\u6027\u3057\u3066\u3057\u307e\u3063\u305f\u8a66\u6599\uff08\u4f8b\uff1a\u713c\u6210\u83d3\u5b50\u3001\u30b9\u30ca\u30c3\u30af\u3001\u30bd\u30fc\u30b9\u985e\uff09\u3067\u3082\u56de\u53ce\u7387\u304c\u5b89\u5b9a\u3057\u3084\u3059\u3044\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002NH\u6cd5\u3092\u57fa\u672c\u6761\u4ef6\u3068\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001\u56de\u53ce\u7387\u304c\u60aa\u3044\u5834\u5408\u306a\u3069\u306f\u4ed6\u306e\u6761\u4ef6\u3092\u88dc\u52a9\u7684\u306b\u4f7f\u7528\u3059\u308b\u3053\u3068\u3082\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<table style=\"width: 100%; border-collapse: collapse; margin-top: 1rem; font-size: 0.82rem;\">\n<thead>\n<tr style=\"background: #0080C3; color: #ffffff;\">\n<th style=\"padding: 0.5rem 0.75rem; text-align: left; border: 1px solid #0070AB;\">\u6761\u4ef6<\/th>\n<th style=\"padding: 0.5rem 0.75rem; text-align: left; border: 1px solid #0070AB;\">\u62bd\u51fa\u65b9\u6cd5<\/th>\n<th style=\"padding: 0.5rem 0.75rem; text-align: left; border: 1px solid #0070AB;\">\u9175\u7d20<\/th>\n<th style=\"padding: 0.5rem 0.75rem; text-align: left; border: 1px solid #0070AB;\">\u524d\u51e6\u7406\u5f37\u5ea6<\/th>\n<th style=\"padding: 0.5rem 0.75rem; text-align: left; border: 1px solid #0070AB;\">\u9069\u3057\u305f\u8a66\u6599<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\"><strong>pNH\u6cd5<\/strong><\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u5316\u5b66\u5909\u6027<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u30c8\u30ea\u30d7\u30b7\u30f3<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u2605\u2605\u2605\uff08\u5f37\uff09<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u9ad8\u5ea6\u52a0\u5de5\u30fb\u96e3\u6eb6\u6027\uff08\u30af\u30c3\u30ad\u30fc\u30fb\u30c1\u30e7\u30b3\uff09<\/td>\n<\/tr>\n<tr style=\"background: #F0F8FF;\">\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\"><strong>pNS\u6cd5<\/strong><\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u71b1\u5909\u6027<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u30c8\u30ea\u30d7\u30b7\u30f3<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u2605\u2605\uff08\u4e2d\u9593\uff09<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u7119\u714e\u30fb\u30da\u30fc\u30b9\u30c8\u30fb\u4e2d\u52a0\u5de5<\/td>\n<\/tr>\n<tr style=\"background: #ffffff;\">\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\"><strong>pHF\u6cd5<\/strong><\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u5ba4\u6e29\u62bd\u51fa<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u30ad\u30e2\u30c8\u30ea\u30d7\u30b7\u30f3<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u2605\uff08\u7a4f\u3084\u304b\uff09<\/td>\n<td style=\"padding: 0.5rem 0.75rem; border: 1px solid #B8D8EA;\">\u7c89\u672b\u30fb\u7d20\u713c\u304d<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><!-- \u2461 \u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066 \u2192 \u7dd1 --><\/p>\n<div style=\"box-sizing: border-box; border-radius: 4px; padding: 1.2rem 1.5rem; margin: 2rem 0; font-size: 0.88rem; line-height: 1.7; background: #D1FAE5; border-left: 4px solid #0D7A3E; color: #1b4332;\" role=\"note\"><strong style=\"font-family: 'Myriad Pro','Helvetica Neue',Helvetica,Arial,sans-serif;\">HF\u6cd5\u3068ELISA\u691c\u67fb\u306e\u9023\u7d9a\u6027\uff1a<br \/>\n<\/strong>HF\u6cd5\u306e\u524d\u51e6\u7406\uff08pHF\u6cd5\uff09\u306f\u3001\u516c\u5b9aELISA\u5b9a\u91cf\u691c\u67fb\uff08\u7b2c1\u6bb5\u968e\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\uff09\u3068\u540c\u4e00\u306e\u62bd\u51fa\u6db2\u300c\u7279\u5b9a\u539f\u6750\u6599\u62bd\u51fa\u6db2 ExSta\u300d\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001ELISA\u691c\u67fb\u3068\u540c\u4e00\u306e\u62bd\u51fa\u30d0\u30c3\u30c1\u304b\u3089\u78ba\u8a8d\u8a66\u9a13\u7528\u8a66\u6599\u3092\u8abf\u88fd\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3059\u3067\u306bELISA\u306b\u3088\u308b\u98df\u54c1\u30a2\u30ec\u30eb\u30b2\u30f3\u691c\u67fb\u3092\u5b9f\u65bd\u3057\u3066\u3044\u308b\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001LC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u306e\u5c0e\u5165\u969c\u58c1\u304c\u4f4e\u3044\u30d7\u30ed\u30b3\u30eb\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u52a0\u5de5\u5ea6\u306e\u9ad8\u3044\u8a66\u6599\u3067\u671f\u5f85\u3059\u308b\u56de\u53ce\u7387\u304c\u5f97\u3089\u308c\u306a\u3044\u5834\u5408\u306f\u3001pNH\u6cd5\u306a\u3069\u3082\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/div>\n<p><!-- \u2462 HF\u6cd5\u3068ELISA\u691c\u67fb\u306e\u9023\u7d9a\u6027 \u2192 \u8584\u3044\u30aa\u30ec\u30f3\u30b8 --><\/p>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     PRODUCT SPOTLIGHT\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<section id=\"product\" class=\"product-section\" style=\"box-sizing: border-box; margin: 0; padding: 4rem 2rem; background: #F7F9FB;\" aria-labelledby=\"product-title\">\n<div class=\"container\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto;\">\n<div class=\"section-eyebrow\" style=\"box-sizing: border-box; margin: 0 0 0.5rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; color: #0080c3; letter-spacing: 0.1em; text-transform: uppercase; font-weight: bold;\">\u516c\u5b9a\u6cd5\u8a18\u8f09\u30ab\u30e9\u30e0<\/div>\n<h2 id=\"product-title\" class=\"section-title\" style=\"box-sizing: border-box; margin: 0 0 1rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: clamp(1.4rem, 3vw, 2rem); font-weight: 900; color: #000000; line-height: 1.3;\">Raptor Inert ARC-18<\/h2>\n<p class=\"section-lead\" style=\"box-sizing: border-box; margin: 0 0 2.5rem 0; padding: 0; font-size: 0.95rem; color: #3a4454; max-width: 680px; line-height: 1.8;\">\u6d88\u8cbb\u8005\u5e81\u516c\u5b9a\u691c\u67fb\u6cd5\uff08NH\u6cd5\uff09\u306b\u304a\u3044\u3066LC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u306e\u516c\u5b9a\u6cd5\u8a18\u8f09\u30ab\u30e9\u30e0\u3068\u3057\u3066\u660e\u8a18\u3055\u308c\u305f\u3001\u98df\u54c1\u30a2\u30ec\u30eb\u30b2\u30f3\u5206\u6790\u5bfe\u5fdcUHPLC\u30ab\u30e9\u30e0\u3002<\/p>\n<div class=\"product-badge-official\" style=\"box-sizing: border-box; margin: 0 0 1rem 0; background: #0080C3; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; padding: 5px 12px; border-radius: 2px; letter-spacing: 0.06em; white-space: nowrap; display: inline-block;\">\u6d88\u8cbb\u8005\u5e81\u516c\u5b9a\u6cd5\uff08NH\u6cd5\uff09\u8a18\u8f09\u30ab\u30e9\u30e0<\/div>\n<div class=\"product-body\" style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<div class=\"reg-confirmed\" style=\"box-sizing: border-box; margin: 0 0 1.5rem 0; background: #D1FAE5; border: 1.5px solid #6EE7B7; border-radius: 4px; padding: 1rem 1.2rem; font-size: 1rem; color: #1b4332; line-height: 1.7;\"><strong style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; color: #0d7a3e;\">\u3010\u516c\u5b9a\u6cd5\u3078\u306e\u8a18\u8f09\u3011<\/strong><br \/>\n\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\uff08\u6700\u7d42\u6539\u6b63\uff1a2026\u5e744\u67081\u65e5\uff09\u7b2c2.2.6.4.2.1\u9805\u306b\u304a\u3044\u3066\u3001<br \/>\nLC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\uff08NH\u6cd5\uff09\u306e\u5206\u6790\u30ab\u30e9\u30e0\u3068\u3057\u3066\u4ee5\u4e0b\u306e\u901a\u308a\u660e\u8a18\u3055\u308c\u3066\u3044\u307e\u3059\u3002<em style=\"box-sizing: border-box; margin: 0.5rem 0 0 0; padding: 0 0 0 1rem; display: block; border-left: 3px solid #0D7A3E; font-size: 0.9rem;\">\u300c\u30aa\u30af\u30bf\u30c7\u30b7\u30eb\u30b7\u30ea\u30eb\u5316\u30b7\u30ea\u30ab\u30b2\u30eb\u30ab\u30e9\u30e0\u306f\u3001<strong style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; color: #0d7a3e;\">Raptor Inert ARC-18 2.7 \u00b5m, 3.0\u00d7100 mm\uff08Restek\u793e\u88fd\uff09<\/strong>\u53c8\u306f\u540c\u7b49\u306e\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u3082\u306e\u3092\u7528\u3044\u308b\u300d<br \/>\n<\/em><cite style=\"box-sizing: border-box; margin: 0.5rem 0 0 0; padding: 0; display: block; font-size: 0.72rem; color: #0d7a3e;\"><br \/>\n\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 [1]<br \/>\n<\/cite><\/div>\n<p style=\"box-sizing: border-box; margin: 0 0 0.6rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #6b7a8d; text-transform: uppercase; letter-spacing: 0.12em;\">\u88fd\u54c1\u4ed5\u69d8<\/p>\n<div class=\"feature-grid\" style=\"box-sizing: border-box; margin: 0 0 0.5rem 0; padding: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)); gap: 1rem;\">\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u7c92\u5b50\u30bf\u30a4\u30d7<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">2.7 \u00b5m SPP\u30b3\u30a2\u30b7\u30a7\u30eb\u30b7\u30ea\u30ab<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u30b5\u30a4\u30ba\uff08\u516c\u5b9a\u6cd5\u8a18\u8f09\u54c1\uff09<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">3.0 mm ID \u00d7 100 mm<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u30ea\u30ac\u30f3\u30c9\u30bf\u30a4\u30d7<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">\u7acb\u4f53\u4fdd\u8b77C18\uff08\u30b9\u30c6\u30ea\u30ab\u30ea\u30fc\u30d7\u30ed\u30c6\u30af\u30c6\u30c3\u30c9\uff09<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u30a8\u30f3\u30c9\u30ad\u30e3\u30c3\u30d7<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">\u306a\u3057<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u30dd\u30a2\u30b5\u30a4\u30ba \/ \u70ad\u7d20\u542b\u6709\u91cf<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">90 \u00c5 \/ 7%<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u8868\u9762\u7a4d<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">130 m\u00b2\/g<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">pH\u8010\u6027<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">1.0\u301c8.0<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u8010\u5727 \/ \u6700\u9ad8\u6e29\u5ea6<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">600 bar\uff088700 psi\uff09\/ 80\u2103<\/div>\n<\/div>\n<\/div>\n<p style=\"box-sizing: border-box; margin: 1.2rem 0 0.6rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #6b7a8d; text-transform: uppercase; letter-spacing: 0.12em;\">\u516c\u5b9a\u6cd5\u5206\u6790\u6761\u4ef6\uff08NH\u6cd5\uff09<br \/>\n<span style=\"box-sizing: border-box; margin: 0; padding: 0; font-weight: 400; color: #6b7a8d;\"> \u203b\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5 \u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5\u3088\u308a<\/span><\/p>\n<div class=\"feature-grid\" style=\"box-sizing: border-box; margin: 0 0 1.5rem 0; padding: 0; display: grid; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)); gap: 1rem;\">\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u30ab\u30e9\u30e0\u6e29\u5ea6<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">50\u2103<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u6d41\u901f<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">0.4 mL\/min<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u6ce8\u5165\u91cf<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">\u2264 10 \u00b5L \u63a8\u5968<\/div>\n<\/div>\n<div class=\"feature-item\" style=\"box-sizing: border-box; margin: 0; padding: 0.9rem 1rem; border-radius: 4px; background: #EEF2F6; border-left: 3px solid #0080C3;\">\n<div class=\"feature-item-title\" style=\"box-sizing: border-box; margin: 0 0 0.25rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #0080c3; text-transform: uppercase; letter-spacing: 0.08em;\">\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0<\/div>\n<div class=\"feature-item-value\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.88rem; color: #3a4454;\">\u516c\u5b9a\u6cd5\u306b\u8a18\u8f09\u306a\u3057<\/div>\n<\/div>\n<\/div>\n<ul class=\"advantage-list\" style=\"box-sizing: border-box; margin: 0 0 1.5rem 0; padding: 0; list-style: none;\">\n<li style=\"box-sizing: border-box; margin: 0; padding: 0.75rem 0; border-bottom: 1px solid #EEF2F6;\">\n<div style=\"box-sizing: border-box; display: flex; align-items: center; gap: 1rem; font-size: 0.88rem; color: #3a4454; line-height: 1.6;\">\n<div style=\"box-sizing: border-box; flex: 0 0 210px; font-weight: bold; color: #000000; line-height: 1.5;\">LC-MS\/MS\u5c02\u7528\u8a2d\u8a08\u306e<br \/>\n\u72ec\u81ea\u306e\u5316\u5b66\u7d50\u5408\u578b\u56fa\u5b9a\u76f8<\/div>\n<div style=\"box-sizing: border-box; flex: 1 1 auto;\">\u7acb\u4f53\u4fdd\u8b77\u30ea\u30ac\u30f3\u30c9\u3092\u6700\u9069\u914d\u7f6e\u3059\u308b\u72ec\u81ea\u306e\u5316\u5b66\u7d50\u5408\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u3088\u308a\u9178\u52a0\u6c34\u5206\u89e3\u3092\u6291\u5236\u3002pH 1.0\u4ee5\u4e0b\u306e\u5f37\u9178\u6027\u79fb\u52d5\u76f8\u306b\u304a\u3044\u3066\u3082\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u30fb\u30d4\u30fc\u30af\u5f62\u72b6\u30fb\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u7dad\u6301\u3002\u30d5\u30a7\u30fc\u30ba\u30d6\u30ea\u30fc\u30c9\u3092\u4f4e\u6e1b\u3057\u3001MS\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3092\u5b89\u5b9a\u5316\u3002<\/div>\n<\/div>\n<\/li>\n<li style=\"box-sizing: border-box; margin: 0; padding: 0.75rem 0; border-bottom: 1px solid #EEF2F6;\">\n<div style=\"box-sizing: border-box; display: flex; align-items: center; gap: 1rem; font-size: 0.88rem; color: #3a4454; line-height: 1.6;\">\n<div style=\"box-sizing: border-box; flex: 0 0 210px; font-weight: bold; color: #000000; line-height: 1.5;\">\u512a\u308c\u305f\u5805\u7262\u6027<\/div>\n<div style=\"box-sizing: border-box; flex: 1 1 auto;\">0.2%\u30ae\u9178\u542b\u6709\u79fb\u52d5\u76f8\u3092\u7528\u3044\u305f\u9023\u7d9a500\u56de\u6ce8\u5165\u5f8c\u3082\u3001\u6a19\u7684\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u306f15\u79d2MRM\u30a6\u30a3\u30f3\u30c9\u30a6\u5185\u3092\u7dad\u6301\u3002\u30ed\u30c3\u30c8\u9593\u518d\u73fe\u6027\u306b\u3064\u3044\u3066\u3082\u72ec\u81eaQC\u898f\u683c\u3067\u4fdd\u8a3c\u3055\u308c\u3066\u304a\u308a\u3001\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u9577\u671f\u5b89\u5b9a\u904b\u7528\u306b\u5bfe\u5fdc\u3002<\/div>\n<\/div>\n<\/li>\n<li style=\"box-sizing: border-box; margin: 0; padding: 0.75rem 0; border-bottom: 1px solid #EEF2F6;\">\n<div style=\"box-sizing: border-box; display: flex; align-items: center; gap: 1rem; font-size: 0.88rem; color: #3a4454; line-height: 1.6;\">\n<div style=\"box-sizing: border-box; flex: 0 0 210px; font-weight: bold; color: #000000; line-height: 1.5;\">Inert\u8868\u9762\u51e6\u7406\u306b\u3088\u308b<br \/>\n\u30da\u30d7\u30c1\u30c9\u5438\u7740\u306e\u6291\u5236<\/div>\n<div style=\"box-sizing: border-box; flex: 1 1 auto;\">\u30b9\u30c6\u30f3\u30ec\u30b9\u8868\u9762\u306b\u65bd\u3057\u305f\u30d7\u30ec\u30df\u30a2\u30e0\u4e0d\u6d3b\u6027\u5316\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306b\u3088\u308a\u3001\u30ad\u30ec\u30fc\u30c8\u6027\u3092\u6301\u3064\u30da\u30d7\u30c1\u30c9\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u975e\u7279\u7570\u7684\u5438\u7740\u3092\u4f4e\u6e1b\u3002\u4e0d\u52d5\u614b\u5316\u51e6\u7406\u3084\u79fb\u52d5\u76f8\u6dfb\u52a0\u5264\u306a\u3057\u3067\u30b7\u30e3\u30fc\u30d7\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u5b9f\u73fe\u3057\u3001\u56de\u53ce\u7387\u3068\u611f\u5ea6\u3092\u6539\u5584\u3002<\/div>\n<\/div>\n<\/li>\n<li style=\"box-sizing: border-box; margin: 0; padding: 0.75rem 0; border-bottom: 1px solid #EEF2F6;\">\n<div style=\"box-sizing: border-box; display: flex; align-items: center; gap: 1rem; font-size: 0.88rem; color: #3a4454; line-height: 1.6;\">\n<div style=\"box-sizing: border-box; flex: 0 0 210px; font-weight: bold; color: #000000; line-height: 1.5;\">\u30b3\u30a2\u30b7\u30a7\u30eb\u7c92\u5b50\uff08SPP\uff09<br \/>\n\u306b\u3088\u308b\u9ad8\u52b9\u7387\u5206\u96e2<\/div>\n<div style=\"box-sizing: border-box; flex: 1 1 auto;\">2.7 \u00b5m\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\u306f\u56fa\u4f53\u30b3\u30a2\u306b\u8584\u3044\u591a\u5b54\u8cea\u30b7\u30ea\u30ab\u5c64\u3092\u6301\u3061\u3001\u62e1\u6563\u7d4c\u8def\u3092\u77ed\u7e2e\u3057\u3066\u30d4\u30fc\u30af\u5206\u6563\u3092\u4f4e\u6e1b\u3002\u5168\u591a\u5b54\u6027\u7c92\u5b50\u3068\u6bd4\u8f03\u3057\u3066\u9ad8\u3044\u7406\u8ad6\u6bb5\u6570\u3092\u63d0\u4f9b\u3057\u3001\u65e2\u5b58HPLC\u3067\u3082UHPLC\u4e26\u307f\u306e\u52b9\u7387\u3092\u5b9f\u73fe\u3002<\/div>\n<div style=\"box-sizing: border-box; flex: 1 1 auto;\"><\/div>\n<\/div>\n<\/li>\n<\/ul>\n<div style=\"box-sizing: border-box; padding: 0; margin: 1.8rem 0 0.5rem;\">\n<p style=\"box-sizing: border-box; margin: 0 0 1rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1rem; font-weight: bold; color: #6b7a8d; text-transform: uppercase; letter-spacing: 0.12em;\">\u30ab\u30e9\u30e0\u7279\u6027\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb<\/p>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0; display: flex; flex-wrap: wrap; gap: 1.5rem; align-items: stretch;\">\n<div style=\"box-sizing: border-box; flex: 1 1 320px; min-width: 280px; background: #F7F9FB; border: 1.5px solid #D8E2EC; border-radius: 4px; padding: 1.2rem; text-align: center;\">\n<p style=\"box-sizing: border-box; margin: 0 0 0.8rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 1.0rem; color: #000000;\">Column Interaction Profile<\/p>\n<p><img decoding=\"async\" style=\"box-sizing: border-box; display: block; width: 100%; max-width: 80%; height: auto; margin: 0 auto 0.8rem auto;\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNBR1970ja_column_interaction_profile_v2.png\" alt=\"Column Interaction Profile\" title=\"-\"><\/p>\n<div style=\"box-sizing: border-box; margin: 0.8rem 0 0 0; padding: 0; text-align: left; font-size: 0.8rem; line-height: 1.6; color: #3a4454;\">\n<div style=\"box-sizing: border-box; margin: 0 0 3px 0; padding: 0; line-height: 1.6;\"><strong>\u4e3b\u8981\u76f8\u4e92\u4f5c\u7528\uff1a<\/strong>Dispersion\uff08\u5206\u6563\u529b\uff09<\/div>\n<div style=\"box-sizing: border-box; margin: 0 0 3px 0; padding: 0; line-height: 1.6;\">\u88dc\u5b8c\uff1aH-Bonding\uff08\u6c34\u7d20\u7d50\u5408\uff09<\/div>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0; line-height: 1.6;\">\u88dc\u5b8c\uff1aCation Exchange\uff08\u30ab\u30c1\u30aa\u30f3\u4ea4\u63db\uff09<\/div>\n<\/div>\n<\/div>\n<div style=\"box-sizing: border-box; flex: 1 1 320px; min-width: 280px; background: #F7F9FB; border: 1.5px solid #D8E2EC; border-radius: 4px; padding: 1.2rem; text-align: center;\">\n<p style=\"box-sizing: border-box; margin: 0 0 1rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 1.0rem; color: #000000;\">Solute Retention Profile<\/p>\n<p><img decoding=\"async\" style=\"box-sizing: border-box; display: block; width: 100%; max-width: 100%; height: auto; margin: 0 auto 0.8rem auto;\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNBR1970ja_solute_retention_profile.png\" alt=\"Solute Retention Profile\" title=\"-\"><\/p>\n<div style=\"box-sizing: border-box; margin: 0.8rem 0 0 0; padding: 0; text-align: left; font-size: 0.75rem; line-height: 1.6; color: #3a4454;\">\n<p style=\"box-sizing: border-box; margin: 0 0 3px 0; padding: 0; font-weight: bold; font-size: 0.9rem; line-height: 1.6;\">Target Analyte Functionalities:<\/p>\n<p style=\"box-sizing: border-box; margin: 0 0 3px 0; padding: 0; font-size: 0.8rem; line-height: 1.6;\">\u2022 Hydrophobic compounds\uff08\u758e\u6c34\u6027\u5316\u5408\u7269\uff09<\/p>\n<p style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.8rem; line-height: 1.6;\">\u2022 Protonated bases\uff08\u30d7\u30ed\u30c8\u30f3\u5316\u5869\u57fa\uff09<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"box-sizing: border-box; margin: 1.2rem 0 0 0; background: #F7F9FB; border: 1.5px solid #D8E2EC; border-radius: 4px; padding: 1.2rem; display: flex; align-items: center; gap: 2rem; flex-wrap: wrap;\">\n<div style=\"box-sizing: border-box; margin: 0; padding: 0; flex-shrink: 0; text-align: center;\"><img decoding=\"async\" style=\"box-sizing: border-box; display: block; width: 60px; max-width: 100%; height: auto; margin: 0 auto;\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnbr1970e-01-370x1024-1.png\" alt=\"Raptor SPP \u30b3\u30a2\u30b7\u30a7\u30eb\u69cb\u9020\u56f3\" title=\"-\"><\/div>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.8rem; color: #3a4454; flex: 1; min-width: 200px;\">\n<p style=\"box-sizing: border-box; margin: 0 0 0.5rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.9rem; color: #000000;\">Raptor SPP \u30b3\u30a2\u30b7\u30a7\u30eb\u69cb\u9020<\/p>\n<p style=\"box-sizing: border-box; margin: 0 0 0.3rem 0; font-size: 0.9rem; padding: 0;\">\u56fa\u4f53\u30b3\u30a2\u3092\u8584\u3044\u591a\u5b54\u8cea\u30b7\u30ea\u30ab\u5c64\u3067\u8986\u3063\u305f<strong style=\"box-sizing: border-box; margin: 0; padding: 0;\">\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\uff08SPP\uff09<\/strong>\u69cb\u9020\u3002\u30a2\u30ca\u30e9\u30a4\u30c8\u306e\u62e1\u6563\u7d4c\u8def\u3092\u77ed\u7e2e\u3057\u30d4\u30fc\u30af\u5206\u6563\u3092\u4f4e\u6e1b\u3002Sterically protected C18\u30ea\u30ac\u30f3\u30c9\u3092Si-O\u3092\u4ecb\u3057\u3066\u7d50\u5408\u3002\u7acb\u4f53\u4fdd\u8b77\u306b\u3088\u308a<strong style=\"box-sizing: border-box; margin: 0; padding: 0;\">\u9178\u52a0\u6c34\u5206\u89e3\u3092\u6291\u5236<\/strong>\u3057\u3001\u5f37\u9178\u6027\u79fb\u52d5\u76f8\uff08pH 1.0\u301c\uff09\u3067\u3082\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u3092\u7dad\u6301\u3002<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"box-sizing: border-box; margin: 1rem 0 0 0; background: #EEF2F6; border-radius: 4px; padding: 1rem 1.2rem; font-size: 0.85rem;\">\n<p style=\"box-sizing: border-box; margin: 0 0 0.6rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 1rem; color: #3a4454; text-transform: uppercase; letter-spacing: 0.08em;\">\u54c1\u756a\uff08\u516c\u5b9a\u6cd5\u8a18\u8f09\u54c1\uff1a3.0 mm \u00d7 100 mm, 2.7 \u00b5m\uff09<\/p>\n<table style=\"box-sizing: border-box; margin: 0; padding: 0; border-collapse: collapse; font-size: 0.82rem; width: 100%; background: #ffffff; border: 1px solid #D8E2EC;\" width=\"100%\">\n<tbody>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0; background: #001F3F; color: white;\">\n<th style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 1rem; text-align: left; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 1rem;\" align=\"left\">\u88fd\u54c1\u540d<\/th>\n<th style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 1rem; text-align: left; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem;\" align=\"left\">Cat.#<\/th>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; font-size: 0.9rem;\"><a style=\"color: #0080c3; text-decoration: none; font-weight: bold; font-size: 0.9rem;\" href=\"https:\/\/www.restek.com\/global\/ja\/p\/9314A1E-T\" target=\"_blank\" rel=\"noopener\"> Raptor Inert ARC-18, 2.7 \u00b5m, 100 \u00d7 3.0 mm <\/a><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; font-family: 'Courier New', Courier, monospace; font-size: 0.9rem;\"><a style=\"color: #0080c3; text-decoration: none; font-weight: bold; font-size: 0.9rem;\" href=\"https:\/\/www.restek.com\/global\/ja\/p\/9314A1E-T\" target=\"_blank\" rel=\"noopener\"> 9314A1E-T <\/a><\/td>\n<\/tr>\n<tr style=\"box-sizing: border-box; margin: 0; padding: 0; background: #F7F9FB;\">\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; font-size: 0.9rem;\"><a style=\"color: #0080c3; text-decoration: none; font-weight: bold; font-size: 0.9rem;\" href=\"https:\/\/www.restek.com\/global\/ja\/p\/9314A0253-T\" target=\"_blank\" rel=\"noopener\"> Raptor Inert ARC-18 EXP \u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8 2.7 \u00b5m, 5 \u00d7 3.0 mm\uff083\u672c\u5165\u3001\u30aa\u30d7\u30b7\u30e7\u30f3\uff09 <\/a><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.65rem 1rem; border-bottom: 1px solid #D8E2EC; font-family: 'Courier New', Courier, monospace; font-size: 0.9rem;\"><a style=\"color: #0080c3; text-decoration: none; font-weight: bold; font-size: 0.9rem;\" href=\"https:\/\/www.restek.com\/global\/ja\/p\/9314A0253-T\" target=\"_blank\" rel=\"noopener\"> 9314A0253-T <\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"box-sizing: border-box; margin: 0.4rem 0 0 0; padding: 0; font-size: 0.7rem; color: #6b7a8d;\">\u203b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u306fEXP\u30c0\u30a4\u30ec\u30af\u30c8\u30b3\u30cd\u30af\u30c8\u30db\u30eb\u30c0 (<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/25808\" target=\"_blank\" rel=\"noopener\">cat.# 25808<\/a>) \u00a0\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<\/div>\n<h3 style=\"box-sizing: border-box; margin: 1.5rem 0 0.8rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; font-weight: bold; color: #000000;\">NH\u6cd5 \u6a19\u7684\u30da\u30d7\u30c1\u30c9\u304a\u3088\u3073MRM\u691c\u51fa\u6761\u4ef6\uff08\u516c\u5b9a\u6cd5\u8a18\u8f09\u5024\uff09<\/h3>\n<table class=\"mrm-table\" style=\"box-sizing: border-box; padding: 0; width: 100%; border-collapse: collapse; font-size: 0.82rem; margin: 1rem 0;\" width=\"100%\" aria-label=\"NH\u6cd5MRM\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\">\n<thead>\n<tr>\n<th style=\"box-sizing: border-box; margin: 0; background: #001F3F; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.6rem 0.9rem; text-align: left; font-size: 0.75rem;\" align=\"left\">\u6a19\u7684\u30da\u30d7\u30c1\u30c9<\/th>\n<th style=\"box-sizing: border-box; margin: 0; background: #001F3F; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.6rem 0.9rem; text-align: left; font-size: 0.75rem;\" align=\"left\">\u914d\u5217<\/th>\n<th style=\"box-sizing: border-box; margin: 0; background: #001F3F; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.6rem 0.9rem; text-align: left; font-size: 0.75rem;\" align=\"left\">\u30d7\u30ea\u30ab\u30fc\u30b5\u30fc\u30a4\u30aa\u30f3 (m\/z)<\/th>\n<th style=\"box-sizing: border-box; margin: 0; background: #001F3F; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.6rem 0.9rem; text-align: left; font-size: 0.75rem;\" align=\"left\">\u30d7\u30ed\u30c0\u30af\u30c8\u30a4\u30aa\u30f3 (m\/z)<\/th>\n<th style=\"box-sizing: border-box; margin: 0; background: #001F3F; color: white; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; padding: 0.6rem 0.9rem; text-align: left; font-size: 0.75rem;\" align=\"left\">\u30ab\u30e9\u30e0\u4fdd\u6301\u6642\u9593\u306e\u76ee\u5b89<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem;\">\u6a19\u7684\u30da\u30d7\u30c1\u30c9\u2460<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem;\"><span style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Courier New', Courier, monospace; font-size: 0.8rem;\">ADIYTPEVGR<\/span><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem;\"><span style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Courier New', Courier, monospace; font-size: 0.8rem;\">560.8<\/span><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem;\"><span style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Courier New', Courier, monospace; font-size: 0.8rem;\">557.3 \/ 658.4 \/ 821.4<\/span><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem;\">\u7d04 7.7 \u5206<\/td>\n<\/tr>\n<tr>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem; background: #F7F9FB;\">\u6a19\u7684\u30da\u30d7\u30c1\u30c9\u2461<\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem; background: #F7F9FB;\"><span style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Courier New', Courier, monospace; font-size: 0.8rem;\">LTTLNSLNLPILK<\/span><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem; background: #F7F9FB;\"><span style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Courier New', Courier, monospace; font-size: 0.8rem;\">720.4<\/span><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem; background: #F7F9FB;\"><span style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Courier New', Courier, monospace; font-size: 0.8rem;\">298.2 \/ 470.3 \/ 1011.6<\/span><\/td>\n<td style=\"box-sizing: border-box; margin: 0; padding: 0.55rem 0.9rem; border-bottom: 1px solid #D8E2EC; font-size: 0.82rem; background: #F7F9FB;\">\u7d04 11.7 \u5206<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"box-sizing: border-box; margin: 0.4rem 0 0 0; padding: 0; font-size: 0.72rem; color: #6b7a8d;\">\u30a4\u30aa\u30f3\u5316\uff1aESI\u6b63\u30a4\u30aa\u30f3\u30e2\u30fc\u30c9\uff08MRM\u30e2\u30fc\u30c9\uff09\u3002\u967d\u6027\u5224\u5b9a\uff1a\u5168\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\u306eS\/N\u6bd4 \u2265 10\u3002<br \/>\n\u6ce8\u5165\u91cf\u306f\u2264 10 \u00b5L\u63a8\u5968\u3002\u4fdd\u6301\u6642\u9593\u306f\u4f7f\u7528\u6a5f\u5668\u306b\u3088\u308a\u7570\u306a\u308b\u5834\u5408\u304c\u3042\u308b\u3002<br \/>\n<cite style=\"box-sizing: border-box; margin: 0; padding: 0;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 \u7b2c2.2.6.4.2.1\u9805 [1]<\/cite><\/p>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     FAQ\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<section class=\"faq-section\" style=\"box-sizing: border-box; margin: 0; padding: 4rem 2rem; background: #EEF2F6;\" aria-labelledby=\"faq-title\">\n<div class=\"container\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto;\">\n<div class=\"section-eyebrow\" style=\"box-sizing: border-box; margin: 0 0 0.5rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.9rem; color: #0080c3; letter-spacing: 0.1em; text-transform: uppercase; font-weight: bold;\">FAQ<\/div>\n<h2 id=\"faq-title\" class=\"section-title\" style=\"box-sizing: border-box; margin: 0 0 1rem 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: clamp(1.4rem, 3vw, 2rem); font-weight: 900; color: #000000; line-height: 1.3;\">\u3088\u304f\u3042\u308b\u3054\u8cea\u554f<\/h2>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0;\">\n<details style=\"box-sizing: border-box; margin: 0 0 0.7rem 0; background: #ffffff; border-radius: 4px; border: 1.5px solid #D8E2EC; overflow: hidden;\">\n<summary style=\"box-sizing: border-box; margin: 0; padding: 1rem 1.4rem; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.9rem; color: #000000; cursor: pointer;\">\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u306e\u30a2\u30ec\u30eb\u30ae\u30fc\u8868\u793a\u7fa9\u52d9\u5316\u306f\u3044\u3064\u65bd\u884c\u3055\u308c\u307e\u3057\u305f\u304b\uff1f<\/summary>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0 1.4rem 1rem; font-size: 0.87rem; color: #3a4454; line-height: 1.75;\">\u6d88\u8cbb\u8005\u5e81\u306f2026\u5e744\u67081\u65e5\u4ed8\u3067\u98df\u54c1\u8868\u793a\u57fa\u6e96\u3092\u6539\u6b63\u3057\u3001\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3092\u7279\u5b9a\u539f\u6750\u6599\uff08\u7fa9\u52d9\u8868\u793a\uff099\u54c1\u76ee\u76ee\u306b\u8ffd\u52a0\u3057\u307e\u3057\u305f\u3002\u516c\u5e03\u65e5\u304b\u30892\u5e74\u9593\u306e\u7d4c\u904e\u63aa\u7f6e\u671f\u9593\u304c\u8a2d\u3051\u3089\u308c\u3066\u304a\u308a\u3001\u5b8c\u5168\u65bd\u884c\u306f<strong>2028\u5e744\u67081\u65e5<\/strong>\u3067\u3059\uff08\u7d4c\u904e\u63aa\u7f6e\u671f\u9593\uff1a2028\u5e743\u670831\u65e5\u307e\u3067\uff09\u3002<br \/>\n<cite style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: #6b7a8d; margin-top: 0.5rem; display: block;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 [1]<\/cite><\/div>\n<\/details>\n<details style=\"box-sizing: border-box; margin: 0 0 0.7rem 0; background: #ffffff; border-radius: 4px; border: 1.5px solid #D8E2EC; overflow: hidden;\">\n<summary style=\"box-sizing: border-box; margin: 0; padding: 1rem 1.4rem; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.9rem; color: #000000; cursor: pointer;\">\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u306e\u516c\u5b9aLC-MS\/MS\u691c\u67fb\u6cd5\u306b\u6307\u5b9a\u3055\u308c\u305f\u30ab\u30e9\u30e0\u306f\u4f55\u3067\u3059\u304b\uff1f<\/summary>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0 1.4rem 1rem; font-size: 0.87rem; color: #3a4454; line-height: 1.75;\">\u6d88\u8cbb\u8005\u5e81\u516c\u5b9a\u691c\u67fb\u6cd5\u306eLC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\uff08NH\u6cd5\uff09\u306b\u304a\u3044\u3066\u3001\u300cRaptor Inert ARC-18 2.7 \u00b5m, 3.0\u00d7100 mm\uff08Restek\u793e\u88fd\uff09\u53c8\u306f\u540c\u7b49\u306e\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u3082\u306e\u3092\u7528\u3044\u308b\u300d\u3068\u7b2c2.2.6.4.2.1\u9805\u306b\u660e\u8a18\u3055\u308c\u3066\u3044\u307e\u3059\u3002NS\u6cd5\u306b\u306fTriart C18 Metal-Free\uff08YMC\uff09\u3001HF\u6cd5\u306b\u306fInertSustain AX-C18\uff08GL Sciences\uff09\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br \/>\n<cite style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: #6b7a8d; margin-top: 0.5rem; display: block;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 [1]<\/cite><\/div>\n<\/details>\n<details style=\"box-sizing: border-box; margin: 0 0 0.7rem 0; background: #ffffff; border-radius: 4px; border: 1.5px solid #D8E2EC; overflow: hidden;\">\n<summary style=\"box-sizing: border-box; margin: 0; padding: 1rem 1.4rem; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.9rem; color: #000000; cursor: pointer;\">ELISA\u6cd5\u3060\u3051\u3067\u306f\u4e0d\u5341\u5206\u306a\u306e\u3067\u3059\u304b\uff1f<\/summary>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0 1.4rem 1rem; font-size: 0.87rem; color: #3a4454; line-height: 1.75;\">ELISA\u6cd5\u306f\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\uff08\u5b9a\u91cf\u691c\u67fb\u30fb\u7b2c1\u6bb5\u968e\uff09\u3068\u3057\u3066\u516c\u5b9a\u6cd5\u3067\u3082\u5f15\u304d\u7d9a\u304d\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3068\u30d4\u30b9\u30bf\u30c1\u30aa\u306f\u4e3b\u8981\u30a2\u30ec\u30eb\u30b2\u30f3\uff082S\u30a2\u30eb\u30d6\u30df\u30f3\uff09\u306e\u30a2\u30df\u30ce\u9178\u914d\u5217\u304c\u7d0469%\u4e00\u81f4\u3059\u308b\u305f\u3081\u3001ELISA\u6cd5\uff08\u6297\u539f\u6297\u4f53\u53cd\u5fdc\uff09\u5358\u72ec\u3067\u306f\u4e21\u8005\u3092\u5b8c\u5168\u306b\u533a\u5225\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u3067\u3059\u3002\u3053\u306e\u305f\u3081\u516c\u5b9a\u6cd5\u3067\u306f\u3001ELISA\u967d\u6027\uff08\u226510 \u00b5g\/g\uff09\u306e\u5834\u5408\u306bLC-MS\/MS\u6cd5\u307e\u305f\u306fPCR\u6cd5\u306b\u3088\u308b\u78ba\u8a8d\u691c\u67fb\uff08\u7b2c2\u6bb5\u968e\uff09\u306e\u5b9f\u65bd\u3092\u898f\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n<cite style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: #6b7a8d; margin-top: 0.5rem; display: block;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81 \u7b2c7\u56de\u98df\u7269\u30a2\u30ec\u30eb\u30ae\u30fc\u8868\u793a\u30a2\u30c9\u30d0\u30a4\u30b6\u30fc\u4f1a\u8b70\u8cc7\u6599\uff082025\u5e741\u670821\u65e5\uff09[3]\u3001\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 [1]<\/cite><\/div>\n<\/details>\n<details style=\"box-sizing: border-box; margin: 0 0 0.7rem 0; background: #ffffff; border-radius: 4px; border: 1.5px solid #D8E2EC; overflow: hidden;\">\n<summary style=\"box-sizing: border-box; margin: 0; padding: 1rem 1.4rem; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.9rem; color: #000000; cursor: pointer;\">3\u3064\u306eLC-MS\/MS\u516c\u5b9a\u6cd5\u306e\u3046\u3061\u3069\u308c\u3092\u9078\u3079\u3070\u3088\u3044\u3067\u3059\u304b\uff1f<\/summary>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0 1.4rem 1rem; font-size: 0.87rem; color: #3a4454; line-height: 1.75;\">\u516c\u5b9a\u6cd5\u306eNH\u6cd5\u30fbNS\u6cd5\u30fbHF\u6cd5\u306f\u3001\u3044\u305a\u308c\u3082\u57fa\u6e96\u3092\u6e80\u305f\u3057\u305f\u6b63\u898f\u306e\u78ba\u8a8d\u8a66\u9a13\u6cd5\u3067\u3042\u308a\u3001\u691c\u67fb\u6a5f\u95a2\u304c\u4efb\u610f\u306b\u9078\u629e\u3067\u304d\u307e\u3059\u3002[1]<br \/>\n\u9078\u629e\u306e\u76ee\u5b89\u306f2\u3064\u306e\u89b3\u70b9\u304b\u3089\u6574\u7406\u3067\u304d\u307e\u3059\u3002<br \/>\n\uff11\uff0e\u8a66\u6599\u30fb\u98df\u54c1\u306e\u6027\u8cea\u306b\u3088\u308b\u9078\u629e<br \/>\n\u9ad8\u5ea6\u52a0\u5de5\u98df\u54c1\uff08\u713c\u6210\u83d3\u5b50\u30fb\u30c1\u30e7\u30b3\u30ec\u30fc\u30c8\u30fb\u30bd\u30fc\u30b9\u985e\u306a\u3069\uff09\u306e\u3088\u3046\u306b\u3001\u52a0\u5de5\u306e\u904e\u7a0b\u3067\u305f\u3093\u3071\u304f\u8cea\u304c\u51dd\u96c6\u30fb\u5909\u6027\u3057\u305f\u72b6\u614b\u306e\u8a66\u6599\u306b\u306fpNH\u6cd5\u304c\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u5316\u5b66\u5909\u6027\u5264\uff08\u5c3f\u7d20\u30fbDTT\uff09\u306b\u3088\u308a\u96e3\u6eb6\u6027\u306e\u305f\u3093\u3071\u304f\u8cea\u3082\u62bd\u51fa\u3067\u304d\u307e\u3059\u3002\u7119\u714e\u30ca\u30c3\u30c4\u3084\u30da\u30fc\u30b9\u30c8\u30fb\u4e2d\u52a0\u5de5\u98df\u54c1\u306b\u306fpNS\u6cd5\uff08\u71b1\u5909\u6027\uff09\u3001\u7d20\u713c\u304d\u3084\u7c89\u672b\u306a\u3069\u52a0\u5de5\u5ea6\u304c\u4f4e\u3044\u8a66\u6599\u306b\u306fpHF\u6cd5\uff08\u5ba4\u6e29\u62bd\u51fa\uff09\u304c\u5bfe\u5fdc\u3057\u3084\u3059\u3044\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n\uff12\uff0e\u30e9\u30dc\u904b\u7528\u306e\u89b3\u70b9\u306b\u3088\u308b\u9078\u629e<br \/>\nELISA\u691c\u67fb\u3068\u306e\u8a66\u6599\u5171\u7528\u3092\u512a\u5148\u3059\u308b\u5834\u5408\u306fHF\u6cd5\uff08\u62bd\u51fa\u6db2ExSta\u304c\u5171\u901a\uff09\u3001\u5185\u6a19\u6e96\u8a66\u85ac\u306a\u3057\u3067\u30b7\u30f3\u30d7\u30eb\u306b\u904b\u7528\u3057\u305f\u3044\u5834\u5408\u306fNH\u6cd5\uff08S\/N\u6bd4\u5224\u5b9a\uff09\u3001\u9ad8\u7cbe\u5ea6\u306a\u5185\u6a19\u6e96\u7ba1\u7406\u3092\u884c\u3044\u305f\u3044\u5834\u5408\u306fNS\u6cd5\u307e\u305f\u306fHF\u6cd5\u304c\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3044\u305a\u308c\u304b1\u6cd5\u306b\u7d5e\u308c\u306a\u3044\u5834\u5408\u306fNH\u6cd5\u3092\u57fa\u672c\u6761\u4ef6\u3068\u3057\u3001\u56de\u53ce\u7387\u304c\u4e0d\u5341\u5206\u306a\u8a66\u6599\u306b\u306e\u307f\u4ed6\u306e\u524d\u51e6\u7406\u3092\u88dc\u52a9\u7684\u306b\u4f7f\u7528\u3059\u308b\u65b9\u6cd5\u3082\u5b9f\u7528\u7684\u3067\u3059\u3002<br \/>\n<cite style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: #6b7a8d; margin-top: 0.5rem; display: block;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 [1]<\/cite><\/div>\n<\/details>\n<details style=\"box-sizing: border-box; margin: 0 0 0.7rem 0; background: #ffffff; border-radius: 4px; border: 1.5px solid #D8E2EC; overflow: hidden;\">\n<summary style=\"box-sizing: border-box; margin: 0; padding: 1rem 1.4rem; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.9rem; color: #000000; cursor: pointer;\">Raptor Inert ARC-18\u306f\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u304c\u5fc5\u8981\u3067\u3059\u304b\uff1f<\/summary>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0 1.4rem 1rem; font-size: 0.87rem; color: #3a4454; line-height: 1.75;\">\u6d88\u8cbb\u8005\u5e81\u516c\u5b9a\u691c\u67fb\u6cd5\uff08NH\u6cd5\uff09\u306b\u306f\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u8a18\u8f09\u306f\u306a\u304f\u3001Raptor Inert ARC-18\u5358\u4f53\u3067\u306e\u4f7f\u7528\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ab\u30e9\u30e0\u4fdd\u8b77\u306e\u89b3\u70b9\u304b\u3089\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u306f\u53ef\u80fd\u3067\u3059\u304c\u3001\u8ffd\u52a0\u3059\u308b\u3068\u30ab\u30e9\u30e0\u9577\u304c\u5897\u3048\u308b\u305f\u3081\u4fdd\u6301\u6642\u9593\u304c\u5909\u5316\u3057\u307e\u3059\u3002\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u540c\u4e00\u56fa\u5b9a\u76f8\u306eARC-18 EXP\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\uff08Cat#.\u00a0<a style=\"color: #0080c3; text-decoration: none; font-weight: bold; font-size: 0.9rem;\" href=\"https:\/\/www.restek.com\/global\/ja\/p\/9314A0253-T\" target=\"_blank\" rel=\"noopener\">9314A0253-T<\/a>\u30015\u00d73.0 mm\uff09\u3092\u9078\u629e\u3057\u3001\u4f7f\u7528\u524d\u306b\u4fdd\u6301\u6642\u9593\u3092\u518d\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br \/>\n<cite style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: #6b7a8d; margin-top: 0.5rem; display: block;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 [1]<\/cite><\/div>\n<\/details>\n<details style=\"box-sizing: border-box; margin: 0 0 0.7rem 0; background: #ffffff; border-radius: 4px; border: 1.5px solid #D8E2EC; overflow: hidden;\">\n<summary style=\"box-sizing: border-box; margin: 0; padding: 1rem 1.4rem; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.9rem; color: #000000; cursor: pointer;\">\u98df\u54c1\u30e1\u30fc\u30ab\u30fc\u306f\u3069\u306e\u3088\u3046\u306a\u691c\u67fb\u5bfe\u5fdc\u304c\u5fc5\u8981\u3067\u3059\u304b\uff1f<\/summary>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0 1.4rem 1rem; font-size: 0.87rem; color: #3a4454; line-height: 1.75;\">\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3092\u539f\u6750\u6599\u3068\u3057\u3066\u4f7f\u7528\u3057\u3066\u3044\u308b\u3001\u307e\u305f\u306f\u4f7f\u7528\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u52a0\u5de5\u98df\u54c1\u30e1\u30fc\u30ab\u30fc\u306f\u3001\u7d4c\u904e\u63aa\u7f6e\u671f\u9593\uff08\u301c2028\u5e743\u670831\u65e5\uff09\u5185\u306b\u2460\u539f\u6750\u6599\u898f\u683c\u66f8\u306e\u78ba\u8a8d\uff08\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u30fb\u30d4\u30b9\u30bf\u30c1\u30aa\u4f7f\u7528\u6709\u7121\uff09\u3001\u2461\u88fd\u54c1\u30e9\u30d9\u30eb\u306e\u6539\u8a02\u3001\u2462\u88fd\u9020\u30e9\u30a4\u30f3\u6d17\u6d44\u8a55\u4fa1\u306b\u3088\u308b\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u7ba1\u7406\u3001\u2463\u5f93\u696d\u54e1\u6559\u80b2\u3001\u306e\u5bfe\u5fdc\u304c\u5fc5\u8981\u3067\u3059\u3002\u81ea\u793e\u691c\u67fb\u307e\u305f\u306f\u7b2c\u4e09\u8005\u691c\u67fb\u6a5f\u95a2\u3078\u306e\u59d4\u8a17\u3044\u305a\u308c\u306e\u5834\u5408\u3082\u3001\u516c\u5b9a\u6cd5\u306b\u6e96\u62e0\u3057\u305f\u691c\u67fb\u65b9\u6cd5\u306e\u63a1\u7528\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002<br \/>\n<cite style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: #6b7a8d; margin-top: 0.5rem; display: block;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 \u5225\u6dfb2\u300c\u5224\u65ad\u6a39\u306b\u3064\u3044\u3066\u300d[1]<\/cite><\/div>\n<\/details>\n<details style=\"box-sizing: border-box; margin: 0; background: #ffffff; border-radius: 4px; border: 1.5px solid #D8E2EC; overflow: hidden;\">\n<summary style=\"box-sizing: border-box; margin: 0; padding: 1rem 1.4rem; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: bold; font-size: 0.9rem; color: #000000; cursor: pointer;\">\u30d4\u30b9\u30bf\u30c1\u30aa\u3082\u7fa9\u52d9\u8868\u793a\u306e\u5bfe\u8c61\u306b\u306a\u308a\u307e\u3057\u305f\u304b\uff1f<\/summary>\n<div style=\"box-sizing: border-box; margin: 0; padding: 0 1.4rem 1rem; font-size: 0.87rem; color: #3a4454; line-height: 1.75;\">\u30d4\u30b9\u30bf\u30c1\u30aa\u306f\u4eca\u56de\u306e\u6539\u6b63\u3067\u300c\u7279\u5b9a\u539f\u6750\u6599\u306b\u6e96\u305a\u308b\u3082\u306e\u300d\uff08\u63a8\u5968\u8868\u793a\u30fb20\u54c1\u76ee\uff09\u306b\u8ffd\u52a0\u3055\u308c\u307e\u3057\u305f\u3002\u7fa9\u52d9\u8868\u793a\uff08\u7279\u5b9a\u539f\u6750\u6599\uff09\u3067\u306f\u306a\u304f\u3001\u53ef\u80fd\u306a\u9650\u308a\u8868\u793a\u3059\u308b\u3088\u3046\u52aa\u3081\u308b\u3053\u3068\u304c\u6c42\u3081\u3089\u308c\u308b\u63a8\u5968\u8868\u793a\u3067\u3059\u3002\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3068\u306e\u4ea4\u5dee\u53cd\u5fdc\u6027\u304b\u3089\u3001\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u30a2\u30ec\u30eb\u30ae\u30fc\u60a3\u8005\u3078\u306e\u60c5\u5831\u63d0\u4f9b\u3068\u3057\u3066\u8868\u793a\u5bfe\u5fdc\u3092\u691c\u8a0e\u3059\u308b\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<br \/>\n<cite style=\"box-sizing: border-box; margin: 0; padding: 0; font-size: 0.75rem; color: #6b7a8d; margin-top: 0.5rem; display: block;\">\u51fa\u5178\uff1a\u6d88\u8cbb\u8005\u5e81\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u6700\u7d42\u6539\u6b632026\u5e744\u67081\u65e5 \u5225\u88681 [1]<\/cite><\/div>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     CTA\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<section class=\"cta-section\" style=\"box-sizing: border-box; margin: 0; background: #001F3F; padding: 4rem 2rem; text-align: center;\" aria-labelledby=\"cta-title\">\n<div class=\"container\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto;\">\n<h2 id=\"cta-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: clamp(1.3rem, 3vw, 1.8rem); font-weight: 900; color: white; margin-bottom: 0.8rem;\">\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4 \u30a2\u30ec\u30eb\u30b2\u30f3\u5206\u6790\u306e<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/>\u691c\u67fb\u4f53\u5236\u6574\u5099\u306f\u304a\u65e9\u3081\u306b<\/h2>\n<p style=\"box-sizing: border-box; margin: 0; padding: 0; color: rgba(255,255,255,0.6); font-size: 0.92rem; margin-bottom: 2rem; max-width: 540px; margin-left: auto; margin-right: auto;\">\u516c\u5b9a\u6cd5\u3078\u306e\u6e96\u62e0\u3001\u30ab\u30e9\u30e0\u9078\u5b9a\u3001\u5206\u6790\u6761\u4ef6\u958b\u767a\u306b\u3064\u3044\u3066Restek\u682a\u5f0f\u4f1a\u793e\u306e\u6280\u8853\u62c5\u5f53\u8005\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002<\/p>\n<div class=\"cta-group\" style=\"box-sizing: border-box; margin: 0; padding: 0; display: flex; gap: 1rem; justify-content: center; flex-wrap: wrap;\"><a class=\"btn-primary\" style=\"box-sizing: border-box; margin: 0; display: inline-flex; align-items: center; gap: 8px; background: #0080C3; color: white; font-family: &#039;Myriad Pro&#039;, &#039;Helvetica Neue&#039;, Helvetica, Arial, &#039;Noto Sans JP&#039;, sans-serif; font-weight: bold; font-size: 0.88rem; padding: 12px 24px; border-radius: 2px; text-decoration: none; transition: all 0.2s ease; letter-spacing: 0.03em;\" href=\"https:\/\/explore.restek.com\/jp_cashew-nut-allergen-test?utm_source=discover_restek_jp&amp;utm_medium=internal_cta&amp;utm_campaign=cashew_allergen_article&amp;utm_id=jpn_cashew_allergen_202606&amp;utm_content=demo_column_contact\" target=\"_blank\" rel=\"noopener\">\u6280\u8853\u76f8\u8ac7\u30fb\u30c7\u30e2\u30ab\u30e9\u30e0\u3054\u8acb\u6c42 \u2192<\/a><br \/>\n<a class=\"btn-outline\" style=\"box-sizing: border-box; margin: 0; display: inline-flex; align-items: center; gap: 8px; background: transparent; color: rgba(255,255,255,0.8); font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-weight: 500; font-size: 0.88rem; padding: 12px 24px; border-radius: 2px; text-decoration: none; border: 1.5px solid rgba(255,255,255,0.3); transition: all 0.2s ease;\" href=\"#product\">Raptor Inert ARC-18 \u4ed5\u69d8\u3092\u78ba\u8a8d\u3059\u308b<\/a><\/div>\n<\/div>\n<\/section>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     SOURCES\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<div class=\"sources-section\" style=\"box-sizing: border-box; margin: 0; padding: 2rem; background: #EEF2F6;\" role=\"complementary\" aria-label=\"\u53c2\u8003\u8cc7\u6599\">\n<div class=\"sources-inner\" style=\"box-sizing: border-box; padding: 0; max-width: 900px; margin: 0 auto;\">\n<div class=\"sources-title\" style=\"box-sizing: border-box; margin: 0; padding: 0; font-family: 'Myriad Pro', 'Helvetica Neue', Helvetica, Arial, 'Noto Sans JP', sans-serif; font-size: 0.68rem; color: #6b7a8d; letter-spacing: 0.15em; text-transform: uppercase; margin-bottom: 0.8rem; font-weight: bold;\">\u53c2\u8003\u8cc7\u6599\u30fb\u51fa\u5178<\/div>\n<ul class=\"sources-list\" style=\"box-sizing: border-box; margin: 0; padding: 0; list-style: none;\">\n<li style=\"box-sizing: border-box; margin: 0; font-size: 0.78rem; color: #6b7a8d; padding: 0.3rem 0; border-bottom: 1px solid #D8E2EC; line-height: 1.5;\">[1] <a style=\"box-sizing: border-box; margin: 0; padding: 0; color: #0080c3; text-decoration: none;\" href=\"https:\/\/www.caa.go.jp\" target=\"_blank\" rel=\"noopener\">\u6d88\u8cbb\u8005\u5e81\uff1a\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\uff08\u6700\u7d42\u6539\u6b63\uff1a2026\u5e744\u67081\u65e5\uff09<\/a><\/li>\n<li style=\"box-sizing: border-box; margin: 0; font-size: 0.78rem; color: #6b7a8d; padding: 0.3rem 0; border-bottom: 1px solid #D8E2EC; line-height: 1.5;\">[2] <a style=\"box-sizing: border-box; margin: 0; padding: 0; color: #0080c3; text-decoration: none;\" href=\"https:\/\/www.caa.go.jp\/policies\/policy\/food_labeling\/meeting_materials\/assets\/food_labeling_cms204_260114_01.pdf\" target=\"_blank\" rel=\"noopener\">\u6d88\u8cbb\u8005\u5e81\uff1a\u7b2c8\u56de\u98df\u7269\u30a2\u30ec\u30eb\u30ae\u30fc\u8868\u793a\u30a2\u30c9\u30d0\u30a4\u30b6\u30fc\u4f1a\u8b70\u8cc7\u6599\uff082025\u5e7412\u670815\u65e5\uff09<\/a><\/li>\n<li style=\"box-sizing: border-box; margin: 0; font-size: 0.78rem; color: #6b7a8d; padding: 0.3rem 0; border-bottom: 1px solid #D8E2EC; line-height: 1.5;\">[3] <a style=\"box-sizing: border-box; margin: 0; padding: 0; color: #0080c3; text-decoration: none;\" href=\"https:\/\/www.caa.go.jp\/policies\/policy\/food_labeling\/meeting_materials\/assets\/food_labeling_cms204_251212_03.pdf\" target=\"_blank\" rel=\"noopener\">\u6d88\u8cbb\u8005\u5e81\uff1a\u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u306e\u7fa9\u52d9\u8868\u793a\u5316\u306b\u5411\u3051\u305f\u691c\u8a0e\u72b6\u6cc1\u306b\u3064\u3044\u3066\uff08\u8cc7\u65991\u30012025\u5e7412\u670815\u65e5\uff09<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p><!-- \u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\n     FOOTER\n\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550\u2550 --><\/p>\n<footer style=\"box-sizing: border-box; margin: 0; background: #000000; color: rgba(255,255,255,0.45); padding: 1.5rem 2rem; font-size: 0.72rem; line-height: 1.8; text-align: center;\" role=\"contentinfo\">\n<p style=\"box-sizing: border-box; margin: 0; padding: 0;\">\u00a9 2026 Restek Corporation. All rights reserved. Printed in the U.S.A.<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><br \/>\nFor information on Restek patents and trademarks, visit<br \/>\n<a style=\"box-sizing: border-box; margin: 0; padding: 0; color: rgba(255,255,255,0.45); text-decoration: underline;\" href=\"https:\/\/www.restek.com\/patents-trademarks\" target=\"_blank\" rel=\"noopener\">www.restek.com\/patents-trademarks<\/a><br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><br \/>\n\u672c\u30da\u30fc\u30b8\u306e\u60c5\u5831\u306f\u6d88\u8cbb\u8005\u5e81\u516c\u5b9a\u691c\u67fb\u6cd5\uff08\u6700\u7d42\u6539\u6b63\uff1a2026\u5e744\u67081\u65e5\uff09\u304a\u3088\u3073\u540c\u5e81\u516c\u958b\u8cc7\u6599\u306b\u57fa\u3065\u3044\u3066\u3044\u307e\u3059\u3002<br \/>\n\u898f\u5236\u5bfe\u5fdc\u306e\u6700\u7d42\u5224\u65ad\u306f\u6d88\u8cbb\u8005\u5e81\u306e\u516c\u5f0f\u767a\u8868\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<br style=\"box-sizing: border-box; margin: 0; padding: 0;\" \/><br \/>\nRaptor\u00ae is a registered trademark of Restek Corporation.<br \/>\nRestek\u00ae Pure Chromatography\u2122<\/p>\n<\/footer>\n<p><script data-cfasync=\"false\" src=\"\/cdn-cgi\/scripts\/5c5dd728\/cloudflare-static\/email-decode.min.js\"><\/script><script><br \/>\n  \/\/ FAQ accordion<br \/>\n  document.querySelectorAll('.faq-q').forEach(q => {<br \/>\n    const toggle = () => {<br \/>\n      const item = q.closest('.faq-item');<br \/>\n      const isOpen = item.classList.contains('open');<br \/>\n      document.querySelectorAll('.faq-item').forEach(i => {<br \/>\n        i.classList.remove('open');<br \/>\n        i.querySelector('.faq-q').setAttribute('aria-expanded', 'false');<br \/>\n        i.querySelector('.faq-a').setAttribute('aria-hidden', 'true');<br \/>\n      });<br \/>\n      if (!isOpen) {<br \/>\n        item.classList.add('open');<br \/>\n        q.setAttribute('aria-expanded', 'true');<br \/>\n        item.querySelector('.faq-a').setAttribute('aria-hidden', 'false');<br \/>\n      }<br \/>\n    };<br \/>\n    q.addEventListener('click', toggle);<br \/>\n    q.addEventListener('keydown', e => { if (e.key === 'Enter' || e.key === ' ') { e.preventDefault(); toggle(); }});<br \/>\n  });<\/p>\n<p>  \/\/ Scroll reveal<br \/>\n  const io = new IntersectionObserver(entries => {<br \/>\n    entries.forEach(e => {<br \/>\n      if (e.isIntersecting) { e.target.style.opacity='1'; e.target.style.transform='translateY(0)'; }<br \/>\n    });<br \/>\n  }, { threshold: 0.08 });<br \/>\n  document.querySelectorAll('.timeline-item, .method-card, .feature-item, .stat-item, .faq-item').forEach(el => {<br \/>\n    el.style.opacity = '0';<br \/>\n    el.style.transfo<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a2\u30ec\u30eb\u30b2\u30f3\u5206\u6790 \u7279\u96c6 2026\u5e744\u67081\u65e5 \u516c\u5b9a\u691c\u67fb\u6cd5 \u65bd\u884c \u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4 \u30a2\u30ec\u30eb\u30b2\u30f3\u8868\u793a\u7fa9\u52d9\u5316 \u5bfe\u5fdc\u30ac\u30a4\u30c9 \u7279\u5b9a\u539f\u6599\u8ffd\u52a0\u3068LC-MS\/MS\u516c\u5b9a\u691c\u67fb\u6cd5 \u6d88\u8cbb\u8005\u5e81\u304c2026\u5e744\u67081\u65e5\u4ed8\u3067\u516c\u8868\u3057\u305f\u516c\u5b9a\u691c\u67fb\u6cd5\u306b\u304a\u3044\u3066\u3001LC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\uff08NH\u6cd5\uff09\u306e\u516c\u5b9a\u6cd5\u8a18\u8f09\u30ab\u30e9\u30e0\u3068\u3057\u3066 Raptor Inert ARC-18 \u304c\u6b63\u5f0f\u306b\u660e\u8a18\u3055\u308c\u307e\u3057\u305f\u3002\u79d1\u5b66\u7684\u6839\u62e0\u306b\u57fa\u3065\u304d\u30013\u3064\u306e\u516c\u5b9a\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002 3\u6cd5\u3092\u6bd4\u8f03\u3059\u308b \u2192 Raptor Inert ARC-18 PDF\u7248\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9 \u2705 \u3010\u516c\u5b9a\u691c\u67fb\u6cd5 \u516c\u8868\u6e08\u307f\u3011 \u6d88\u8cbb\u8005\u5e81\u306f2026\u5e744\u67081\u65e5\u4ed8\u3067\u300c\u30a2\u30ec\u30eb\u30b2\u30f3\u3092\u542b\u3080\u98df\u54c1\u306e\u691c\u67fb\u65b9\u6cd5\u300d\u3092\u6700\u7d42\u6539\u6b63\u30fb\u516c\u8868\u3057\u307e\u3057\u305f\u3002 \u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u306f\u7279\u5b9a\u539f\u6750\u65999\u54c1\u76ee\u76ee\u306b\u8ffd\u52a0\u3055\u308c\u3001LC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\uff08NH\u6cd5\uff09\u306b Raptor Inert ARC-18\uff08Restek\u793e\u88fd\uff09\u304c\u516c\u5b9a\u6cd5\u8a18\u8f09\u30ab\u30e9\u30e0\u3068\u3057\u3066\u660e\u8a18\u3055\u308c\u3066\u3044\u307e\u3059\u3002 \u6d88\u8cbb\u8005\u5e81\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8\u3067\u78ba\u8a8d 9\u54c1\u76ee \u7279\u5b9a\u539f\u6750\u6599\uff08\u7fa9\u52d9\u8868\u793a\uff09\u306e\u6570 \u51fa\u5178\uff1a[1] 10 \u00b5g\/g \u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u967d\u6027\u5224\u5b9a\u95be\u5024 \u51fa\u5178\uff1a[1] 69% \u30ab\u30b7\u30e5\u30fc\/\u30d4\u30b9\u30bf\u30c1\u30aa\u4e3b\u8981\u30a2\u30ec\u30eb\u30b2\u30f3\u914d\u5217\u4e00\u81f4\u7387 \u51fa\u5178\uff1a[3] 3\u6cd5 \u516c\u5b9aLC-MS\/MS\u78ba\u8a8d\u8a66\u9a13\u6cd5\u306e\u6570 \u51fa\u5178\uff1a[1] 2\u5e74\u9593 \u7d4c\u904e\u63aa\u7f6e\u671f\u9593\u301c2028\u5e743\u670831\u65e5 \u51fa\u5178\uff1a[1] \u898f\u5236\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb \u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4 \u30a2\u30ec\u30eb\u30ae\u30fc\u8868\u793a\u7fa9\u52d9\u5316\u306e\u7d4c\u7def 2025\u5e741\u6708 \u7b2c7\u56de\u30a2\u30c9\u30d0\u30a4\u30b6\u30fc\u4f1a\u8b70 \u2014 \u7fa9\u52d9\u5316\u65b9\u91dd\u306e\u6c7a\u5b9a\u5b8c\u4e86 \u30ab\u30b7\u30e5\u30fc\u30ca\u30c3\u30c4\u3092\u300c\u7279\u5b9a\u539f\u6750\u6599\u306b\u6e96\u305a\u308b\u3082\u306e\u300d\u304b\u3089\u300c\u7279\u5b9a\u539f\u6750\u6599\u300d\uff08\u7fa9\u52d9\u8868\u793a\uff09\u3078\u79fb\u884c\u3059\u308b\u65b9\u91dd\u3092\u767a\u8868\u3002\u30d4\u30b9\u30bf\u30c1\u30aa\u306e\u63a8\u5968\u8868\u793a\u54c1\u76ee\u8ffd\u52a0\u3082\u6c7a\u5b9a\u3002\u516c\u5b9a\u691c\u67fb\u6cd5\u78ba\u7acb\u3092\u6761\u4ef6\u3068\u3057\u305f\u3002 2025\u5e7412\u6708 \u7b2c8\u56de\u30a2\u30c9\u30d0\u30a4\u30b6\u30fc\u4f1a\u8b70&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"default","_kad_post_title":"show","_kad_post_layout":"normal","_kad_post_sidebar_id":"","_kad_post_content_style":"unboxed","_kad_post_vertical_padding":"hide","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[789],"tags":[2704],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2571],"resource-technique":[],"ppma_author":[414],"class_list":["post-92236","post","type-post","status-publish","format-standard","hentry","category-articles-ja","tag-faq-inert-lc-columns","product-library-lc-columns-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2704,"label":"FAQ: Inert LC Columns"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":459,"filter":"raw","cat_ID":789,"category_count":459,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2704,"name":"FAQ: Inert LC Columns","slug":"faq-inert-lc-columns","term_group":0,"term_taxonomy_id":2704,"taxonomy":"post_tag","description":"Browse frequently asked questions for inert LC columns.","parent":0,"count":16,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/92236","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=92236"}],"version-history":[{"count":148,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/92236\/revisions"}],"predecessor-version":[{"id":96013,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/92236\/revisions\/96013"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=92236"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=92236"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=92236"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=92236"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=92236"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=92236"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=92236"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=92236"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=92236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}