{"id":92832,"date":"2026-03-30T10:34:00","date_gmt":"2026-03-30T10:34:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=92832"},"modified":"2026-05-21T02:47:16","modified_gmt":"2026-05-21T02:47:16","slug":"automating-spe-for-pfas-extraction-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evar5645-ja\/automating-spe-for-pfas-extraction-ja","title":{"rendered":"PFAS\u5206\u6790\u7528\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u524d\u51e6\u7406\u306e\u81ea\u52d5\u5316\uff5cPromoChrom SPE-03\u3068Resprep PFAS\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3067\u524d\u51e6\u7406\u3092\u52b9\u7387\u5316"},"content":{"rendered":"\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Key Highlights<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>PromoChrom SPE-03\u30b7\u30b9\u30c6\u30e0\u306b\u3088\u308a\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u3092\u81ea\u52d5\u5316\u3057\u3001PFAS\u5206\u6790\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u52b9\u7387\u7684\u306b\u904b\u7528\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\uff08\u308d\u904e\u52a9\u5264\uff09\u5165\u308a\u56fa\u76f8\u62bd\u51fa Resprep PFAS\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u3088\u308a\u3001\u7cbe\u5ea6\u3068\u4fe1\u983c\u6027\u306b\u512a\u308c\u305f\u5206\u6790\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u5145\u586b\u6e08\u307f\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u304c\u76ee\u8a70\u307e\u308a\u304a\u3088\u3073\u518d\u62bd\u51fa\u306e\u624b\u9593\u3092\u9632\u304e\u3001\u6642\u9593\u77ed\u7e2e\u3068\u7701\u529b\u5316\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b\uff1aPFAS\u5206\u6790\u306b\u304a\u3051\u308b\u524d\u51e6\u7406 \u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u306e\u5f79\u5272\uff5e\u81ea\u52d5\u5316\u3078<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u74b0\u5883\u5206\u6790\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u306fPFAS\uff08\u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff09\u5206\u6790\u306e\u8981\u3068\u3044\u3048\u308b\u524d\u51e6\u7406\u6280\u8853\u3067\u3059\u3002\u307b\u3068\u3093\u3069\u306eEPA\u30e1\u30bd\u30c3\u30c9\u3084ASTM\u30e1\u30bd\u30c3\u30c9\u3067\u3082SPE\u306e\u4f7f\u7528\u304c\u898f\u5b9a\u3055\u308c\u3066\u304a\u308a\u3001\u73fe\u5834\u3078\u306e\u666e\u53ca\u5ea6\u306f\u9ad8\u3044\u72b6\u6cc1\u306b\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u306f\u30b9\u30c1\u30ec\u30f3-\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\uff08SDVB\uff09\u7cfb\u307e\u305f\u306f\u5f31\u30a2\u30cb\u30aa\u30f3\u4ea4\u63db\uff08WAX\uff09\u7cfb\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u7528\u3044\u3066\u3044\u308b\u306e\u3067\u3001\u6eb6\u5a92\u3092\u5927\u91cf\u306b\u6d88\u8cbb\u3059\u308b\u5206\u6db2\u30ed\u30fc\u30c8\u3084\u9023\u7d9a\u3057\u305f\u6db2-\u6db2\u62bd\u51fa\u3068\u3044\u3063\u305f\u624b\u6cd5\u3092\u4f7f\u308f\u305a\u306b\u3001\u6c34\u6027\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089PFAS\u5316\u5408\u7269\u3092\u52b9\u7387\u7684\u306b\u62bd\u51fa\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001\u56fa\u4f53\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u304a\u3044\u3066\u3082\u3001\u6eb6\u5a92\u62bd\u51fa\u3068\u6c34\u4ea4\u63db\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u5bfe\u5fdc\u304c\u53ef\u80fd\u3067\u3059\u3002\u5f93\u6765\u3001SPE\u306f\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u3067\u624b\u52d5\u64cd\u4f5c\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u30b7\u30b9\u30c6\u30e0\u306e\u81ea\u52d5\u5316\u304c\u9032\u3093\u3067\u3044\u308b\u305f\u3081\u3001\u4f5c\u696d\u52b9\u7387\u304c\u5927\u5e45\u306b\u5411\u4e0a\u3057\u3066\u304d\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u304b\u3089\u306e\u8131\u5374\uff1aPFAS\u5206\u6790\u306eSPE\u81ea\u52d5\u5316<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u304f\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u3092\u4f7f\u7528\u3057\u305f\u624b\u52d5SPE\u304c\u60f3\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307b\u3068\u3093\u3069\u306e\u30e1\u30bd\u30c3\u30c9\u306b\u304a\u3044\u3066\u81ea\u52d5SPE\u306b\u3064\u3044\u3066\u306f\u300c\u4f7f\u7528\u53ef\u80fd\u300d\u3068\u8a00\u53ca\u3055\u308c\u308b\u7a0b\u5ea6\u3067\u3059\u304c\u3001\u305d\u308c\u306f\u88c5\u7f6e\u9593\u306e\u4e92\u63db\u6027\u304c\u306a\u3044\u305f\u3081\u3001\u5177\u4f53\u7684\u306a\u5b9f\u88c5\u65b9\u6cd5\u304c\u660e\u8a18\u3067\u304d\u306a\u3044\u304b\u3089\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u81ea\u52d5SPE\u306e\u5c0e\u5165\u65b9\u6cd5\u3068\u3001\u4f7f\u7528\u3059\u308b\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u30e1\u30bd\u30c3\u30c9\u9069\u5408\u6027\u306f\u5404\u30e9\u30dc\u3067\u78ba\u8a8d\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u524d\u306e\u7814\u7a76\u3067\u306f\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u5165\u308a\u306e\u4e8c\u5c64\u5f0fResprep PFAS SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8 (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/28931\" target=\"_blank\" rel=\"noreferrer noopener\">28931<\/a>) \u304c<strong>Thermo AutoTrace 280 PFAS\u30b7\u30b9\u30c6\u30e0<\/strong>\u3067\u826f\u597d\u306a\u7d50\u679c\u3092\u793a\u3059\u3053\u3068\u304c\u5b9f\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059[1]\u3002\u3053\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001\u30ab\u30fc\u30dc\u30f3\u5c64\u3068WAX\u5c64\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u4e8c\u5c64\u69cb\u9020\uff08\u30c7\u30e5\u30a2\u30eb\u30d9\u30c3\u30c9\uff09\u3092\u63a1\u7528\u3057\u3066\u3044\u308b\u305f\u3081\u3001WAX\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u30ab\u30fc\u30dc\u30f3\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u5225\u3005\u306b\u4f7f\u7528\u3059\u308b\u5834\u5408\u3068\u6bd4\u3079\u3066\u3001\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u3088\u308a\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u8fc5\u901f\u306b\u5b8c\u4e86\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u306f\u51fa\u8377\u6642\u306b\u5145\u586b\u6e08\u307f\u306e\u305f\u3081\u3001\u61f8\u6fc1\u7269\u8cea\u304c\u591a\u304f\u542b\u307e\u308c\u308b\u30b5\u30f3\u30d7\u30eb\u3067\u3082\u76ee\u8a70\u307e\u308a\u3092\u9632\u304e\u30011\u56de\u306e\u62bd\u51fa\u3067\u524d\u51e6\u7406\u304c\u5b8c\u4e86\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306e\u7814\u7a76\u3067\u3001Resprep PFAS SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u8907\u6570\u306e\u7af6\u5408\u4ed6\u793e\u88fd\u30c7\u30e5\u30a2\u30eb\u30d9\u30c3\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3001\u304a\u3088\u3073\u5358\u5c64WAX\u5c02\u7528\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u306e\u6027\u80fd\u6bd4\u8f03\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u81ea\u52d5\u5316\u306b\u4f7f\u7528\u3057\u305f\u306e\u306f<strong>PromoChrom\u793e\u306eSPE-03\u30b7\u30b9\u30c6\u30e0<\/strong>\u3067\u3001\u3053\u308c\u306f\u4ee5\u524d\u306e\u7814\u7a76\u3067\u4f7f\u7528\u3057\u305f\u3082\u306e\u3068\u306f\u7570\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u30d7\u30ed\u30b0\u30e9\u30e0\u53ef\u80fd\u306a\u7d71\u5408\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3001\u30dc\u30c8\u30eb\u30ea\u30f3\u30b9\u6a5f\u80fd\u3001\u305d\u3057\u3066\u30b3\u30f3\u30d1\u30af\u30c8\u306a\u8a2d\u7f6e\u9762\u7a4d\u3068\u3044\u3063\u305f\u5229\u4fbf\u6027\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306e\u7814\u7a76\u76ee\u7684\u306f2\u3064\u3067\u3059\u3002\u2460SPE-03\u88c5\u7f6e\u3068\u306e\u4e92\u63db\u6027\u78ba\u8a8d\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u78ba\u7acb\u3001\u2461\u5404\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u6027\u80fd\u6bd4\u8f03\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u81ea\u52d5\u5316\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3078\u306e\u30e1\u30bd\u30c3\u30c9\u79fb\u7ba1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u5206\u6790\u306eSPE\u3092\u81ea\u52d5\u5316\u3059\u308b\u969b\u306b\u307e\u305a\u8ab2\u984c\u3068\u306a\u308b\u306e\u306f\u3001\u30e1\u30bd\u30c3\u30c9\u306b\u8a18\u8f09\u3055\u308c\u305f\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u306e\u64cd\u4f5c\u624b\u9806\u3092SPE\u88c5\u7f6e\u306b\u5909\u63db\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u591a\u304f\u306e\u88c5\u7f6e\u3067\u306f\u3001SPE\u30d7\u30ed\u30bb\u30b9\u3092\u30b9\u30c6\u30c3\u30d7\u3054\u3068\u306b\u8a73\u7d30\u306b\u8a18\u8ff0\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u305f\u3081\u3001\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u3092\u4f7f\u3046\u5834\u5408\u3088\u308a\u3082\u624b\u9806\u304c\u8907\u96d1\u306b\u898b\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u5404\u30b9\u30c6\u30c3\u30d7\u306e\u610f\u5473\u3092\u7406\u89e3\u3057\u3066\u3057\u307e\u3048\u3070\u3001\u81ea\u52d5\u5316\u30e1\u30bd\u30c3\u30c9\u3078\u306e\u79fb\u884c\u306f\u6bd4\u8f03\u7684\u30b9\u30e0\u30fc\u30ba\u306b\u9032\u3081\u3089\u308c\u307e\u3059\u3002\u672c\u7814\u7a76\u3067\u4f7f\u7528\u3057\u305fPromoChrom\u30e1\u30bd\u30c3\u30c9\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u3092<strong>Table I<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> PFAS\u5206\u6790SPE\u81ea\u52d5\u5316\u306e\u305f\u3081\u306ePromoChrom SPE-03\u30d1\u30e9\u30e1\u30fc\u30bf (EPA Method 1633\u6e96\u62e0)<\/p>\n\n\n<p><style>\n.spe-t{width:100%;border-collapse:collapse;font-size:1em;color:#222}<br \/>\n.spe-t th,.spe-t td{padding:6px 10px;border:1px solid #ccc;text-align:center;vertical-align:middle}<br \/>\n.spe-t th{background:#eef0f2;font-weight:700;color:#222}<br \/>\n.spe-t td:first-child{text-align:left;white-space:nowrap}<br \/>\n.spe-t td:nth-child(2){text-align:left}<br \/>\n.spe-t td:nth-child(3){text-align:left}<br \/>\n<\/style>\n<\/p>\n<table class=\"spe-t\">\n<tbody>\n<tr>\n<th>\u4f5c\u696d<\/th>\n<th>Inlet 1<br \/>(\u6eb6\u5a92\/\u30b5\u30f3\u30d7\u30eb)<\/th>\n<th>Inlet 2<br \/>(\u30a8\u30a2\u6bd4\u7387)<\/th>\n<th>\u6d41\u901f(mL\/min)<\/th>\n<th>\u5bb9\u91cf (mL)<\/th>\n<th>\u6642\u9593<\/th>\n<\/tr>\n<tr>\n<td>Waste 2\u306b\u6eb6\u51fa<\/td>\n<td>1% \u30a2\u30f3\u30e2\u30cb\u30a2\u542b\u6709\u30e1\u30bf\u30ce\u30fc\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>8<\/td>\n<td>15<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>Waste 1\u306b\u6eb6\u51fa<\/td>\n<td>0.3 M \u30ae\u9178\u6c34\u6eb6\u6db2<\/td>\n<td>\u00a0<\/td>\n<td>8<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u30b5\u30f3\u30d7\u30eb\u3092Waste 1\u306b\u6dfb\u52a0<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>560<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u6d17\u6d44<\/td>\n<td>\u6c34<\/td>\n<td>20%<\/td>\n<td>70<\/td>\n<td>2.5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u30b5\u30f3\u30d7\u30eb\u3092Waste 1\u306b\u6dfb\u52a0<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u6d17\u6d44<\/td>\n<td>\u6c34<\/td>\n<td>20%<\/td>\n<td>70<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u30b5\u30f3\u30d7\u30eb\u3092Waste 1\u306b\u6dfb\u52a0<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u6d17\u6d44<\/td>\n<td>\u6c34<\/td>\n<td>20%<\/td>\n<td>70<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u30b5\u30f3\u30d7\u30eb\u3092Waste 1\u306b\u6dfb\u52a0<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u632f\u3068\u3046<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>20 \u79d2<\/td>\n<\/tr>\n<tr>\n<td>\u6d17\u6d44<\/td>\n<td>1:1 0.1 M formic acid:methanol<\/td>\n<td>20%<\/td>\n<td>70<\/td>\n<td>1.3<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u30b5\u30f3\u30d7\u30eb\u3092Waste 1\u306b\u6dfb\u52a0<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>3<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u6d17\u6d44<\/td>\n<td>1:1 0.1 M \u30ae\u9178:\u30e1\u30bf\u30ce\u30fc\u30eb<\/td>\n<td>20%<\/td>\n<td>70<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u30b5\u30f3\u30d7\u30eb\u3092Waste 2\u306b\u6dfb\u52a0<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u632f\u3068\u3046<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>20 \u79d2<\/td>\n<\/tr>\n<tr>\n<td>Waste 2\u3078\u30a8\u30a2\u30d1\u30fc\u30b8<\/td>\n<td>\u30a8\u30a2<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>3<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u30b5\u30f3\u30d7\u30eb\u3092Waste 2\u306b\u6dfb\u52a0<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u7a92\u7d20\u30d6\u30ed\u30fc<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>1 \u5206<\/td>\n<\/tr>\n<tr>\n<td>\u6d17\u6d44<\/td>\n<td>1% \u30a2\u30f3\u30e2\u30cb\u30a2\u542b\u6709\u30e1\u30bf\u30ce\u30fc\u30eb<\/td>\n<td>20%<\/td>\n<td>70<\/td>\n<td>1.3<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u5bb9\u56681\u306b\u56de\u53ce<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>3<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u6d17\u6d44<\/td>\n<td>1% \u30a2\u30f3\u30e2\u30cb\u30a2\u542b\u6709\u30e1\u30bf\u30ce\u30fc\u30eb<\/td>\n<td>20%<\/td>\n<td>70<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u5bb9\u56681\u306b\u56de\u53ce<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u632f\u3068\u3046<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>10 \u79d2<\/td>\n<\/tr>\n<tr>\n<td>\u5bb9\u56681\u306b\u56de\u53ce<\/td>\n<td>\u30b5\u30f3\u30d7\u30eb<\/td>\n<td>\u00a0<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>\u5f85\u6a5f<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>\u00a0<\/td>\n<td>1 \u5206<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u306e\u8a55\u4fa1<\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">PromoChrom\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u305f\u81ea\u52d5SPE\u306b\u304a\u3044\u3066\u3001\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u6027\u80fd\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u3001\u8131\u30a4\u30aa\u30f3\u6c34\u306bPFAS 28\u6210\u5206\u6df7\u5408\u6a19\u6e96\u6db2 (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/30734\" target=\"_blank\" rel=\"noreferrer noopener\">30734<\/a>) \u30925 ng\/L\u3067\u6dfb\u52a0\u3057\u305f\u3082\u306e\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002SPE\u30d7\u30ed\u30bb\u30b9\u81ea\u4f53\u306e\u6b63\u78ba\u306a\u56de\u53ce\u7387\u3092\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u3001\u62bd\u51fa\u7528\u306e\u5185\u6a19\u6e96\u7269\u8cea\u306f\u4f7f\u7528\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u8a55\u4fa1\u5bfe\u8c61\u306f\u4ee5\u4e0b\u306e3\u7a2e\u985e\u3067\u3059\u3002<strong>Figure 1<\/strong>\u306b\u3001\u5404\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u5e73\u5747\u56de\u53ce\u7387\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Resprep WAX\u30dd\u30ea\u30de\u30fcSPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8 (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/28268\" target=\"_blank\" rel=\"noreferrer noopener\">28268<\/a>)<\/li>\n\n\n\n<li>\u56fa\u76f8\u62bd\u51faResprep PFAS\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8|\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u5165\u308a(cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/28931\" target=\"_blank\" rel=\"noreferrer noopener\">28931<\/a>)<\/li>\n\n\n\n<li>\u7af6\u5408\u4ed6\u793e3\u793e\u88fd\u306e\u30c7\u30e5\u30a2\u30eb\u30d9\u30c3\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\uff08WAX\/\u30ab\u30fc\u30dc\u30f3\uff09<\/li>\n<\/ul>\n<\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> PromoChrom SPE-03\u3092\u7528\u3044\u305f5 ng\/L\u6dfb\u52a0\u30b5\u30f3\u30d7\u30eb\u306e\u5e73\u5747\u56de\u53ce\u7387<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92832_637579-32 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image92832_637579-32\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"567\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-01.jpg\" alt=\"recoveries bar chart\" class=\"kb-img wp-image-91087\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-01.jpg 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-01-300x127.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-01-1024x433.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-01-768x325.jpg 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u56de\u53ce\u7387\u306b\u3064\u3044\u3066\u306f\u3001\u307b\u3068\u3093\u3069\u306ePFAS\u5316\u5408\u7269\u3067\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u9593\u3067\u306e\u9055\u3044\u306f\u78ba\u8a8d\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u305f\u3060\u3057\u3001\u6eb6\u51fa\u304c\u9045\u3044\u3044\u304f\u3064\u304b\u306e\u9577\u9396PFAS\u5316\u5408\u7269\u306b\u95a2\u3057\u3066\u306f\u50be\u5411\u304c\u7570\u306a\u308a\u307e\u3059\u3002WAX\u5c02\u7528\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3059\u3079\u3066\u306eWAX\/\u30ab\u30fc\u30dc\u30f3\u30c7\u30e5\u30a2\u30eb\u30d9\u30c3\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u4e0a\u56de\u308b\u56de\u53ce\u7387\u3092\u793a\u3057\u3066\u304a\u308a\u3001\u3053\u308c\u306f\u30ab\u30fc\u30dc\u30f3\u5c64\u304c\u9577\u9396PFAS\u5316\u5408\u7269\u3092\u3088\u308a\u5f37\u304f\u4fdd\u6301\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u7af6\u5408\u793e3\uff08<strong>Figure 1 <\/strong>\u306eCompetitor 3\uff09\u306b\u3064\u3044\u3066\u306f\u7279\u306b\u9855\u8457\u3067\u3001\u4e00\u90e8\u306e\u5316\u5408\u7269\u3067\u306f40%\u672a\u6e80\u3068\u3044\u3046\u4f4e\u3044\u56de\u53ce\u7387\u3068\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 2<\/strong>\u306b\u3001\u5404\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u518d\u73fe\u6027\u3092\u793a\u3057\u307e\u3059\u3002\u5168\u4f53\u3068\u3057\u3066\u3001Restek\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u307b\u3068\u3093\u3069\u306ePFAS\u5316\u5408\u7269\u3067%RSD 15%\u3092\u5927\u304d\u304f\u4e0b\u56de\u308a\u3001\u7af6\u5408\u4ed6\u793e\u88fd\u54c1\u3088\u308a\u826f\u597d\u306a\u7d50\u679c\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u6eb6\u51fa\u304c\u9045\u3044\u5316\u5408\u7269\u307b\u3069%RSD\u306f\u308f\u305a\u304b\u306b\u4e0a\u6607\u3059\u308b\u50be\u5411\u304c\u898b\u3089\u308c\u307e\u3059\u304c\u3001\u3053\u308c\u3082\u30ab\u30fc\u30dc\u30f3\u5c64\u306b\u3088\u308b\u4fdd\u6301\u304c\u5f71\u97ff\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u7af6\u5408\u793e3\uff08<strong>Figure 2 <\/strong>\u306eCompetitor 3\uff09\u306b\u3064\u3044\u3066\u306f\u3001<strong>Figure 1<\/strong>\u306b\u793a\u3057\u305f\u4f4e\u3044\u56de\u53ce\u7387\u306b\u52a0\u3048\u3066\u3001\u3053\u3053\u3067\u3082\u5927\u304d\u306a\u3070\u3089\u3064\u304d\u3092\u793a\u3059\u7d50\u679c\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u5168PFAS\u3092\u5bfe\u8c61\u3068\u3057\u305f\u5e73\u5747\u56de\u53ce\u7387\u3068\u518d\u73fe\u6027\u306f<strong>Table II<\/strong>\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> PromoChrom SPE-03\u3092\u7528\u3044\u305f5 ng\/L\u6dfb\u52a0\u30b5\u30f3\u30d7\u30eb\u306e\u518d\u73fe\u6027<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92832_349bc9-1c .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image92832_349bc9-1c\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"512\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-02.jpg\" alt=\"precision bar chart\" class=\"kb-img wp-image-91075\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-02.jpg 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-02-300x115.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-02-1024x391.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAR5645-02-768x293.jpg 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u5168\u5bfe\u8c61PFAS\u5316\u5408\u7269\u306e\u5e73\u5747\u56de\u53ce\u7387\u3068\u518d\u73fe\u6027<\/p>\n\n\n<p><style>\n.spe-cmp-t{width:auto;border-collapse:collapse;font-size:1em;color:#222}<br \/>\n.spe-cmp-t th,.spe-cmp-t td{padding:6px 10px;border:1px solid #ccc;text-align:center;vertical-align:middle}<br \/>\n.spe-cmp-t th{background:#eef0f2;font-weight:700;color:#222}<br \/>\n.spe-cmp-t td:first-child{text-align:left}<br \/>\n<\/style><\/p>\n<table class=\"spe-cmp-t\">\n<tbody>\n<tr>\n<th>SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/th>\n<th>\u5e73\u5747\u56de\u53ce\u7387<\/th>\n<th>\u5e73\u5747 %RSD<\/th>\n<\/tr>\n<tr>\n<td>Resprep polymeric (WAX\u306e\u307f)<\/td>\n<td>102.2%<\/td>\n<td>5.8%<\/td>\n<\/tr>\n<tr>\n<td>Resprep PFAS + Filter Aid (WAX\/\u30ab\u30fc\u30dc\u30f3)<\/td>\n<td>99.6%<\/td>\n<td>7.9%<\/td>\n<\/tr>\n<tr>\n<td>Competitor 1 (WAX\/\u30ab\u30fc\u30dc\u30f3)<\/td>\n<td>98.7%<\/td>\n<td>9.0%<\/td>\n<\/tr>\n<tr>\n<td>Competitor 2 (WAX\/\u30ab\u30fc\u30dc\u30f3)<\/td>\n<td>87.7%<\/td>\n<td>10.0%<\/td>\n<\/tr>\n<tr>\n<td>Competitor 3 (WAX\/\u30ab\u30fc\u30dc\u30f3)<\/td>\n<td>75.7%<\/td>\n<td>15.3%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u307e\u3068\u3081\u3000<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Resprep WAX\u304a\u3088\u3073WAX\/\u30ab\u30fc\u30dc\u30f3SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001\u4ee3\u8868\u7684\u306a\u81ea\u52d5\u5316\u3055\u308c\u305fSPE\u30b7\u30b9\u30c6\u30e0\u3068\u306e\u4e92\u63db\u6027\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001PFAS\u5206\u6790\u306eSPE\u81ea\u52d5\u5316\u3092\u691c\u8a0e\u3057\u3066\u3044\u308b\u30e9\u30dc\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u30b9\u30e0\u30fc\u30ba\u306b\u52b9\u7387\u5316\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u5165\u308aResprep PFAS SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001\u4ed6\u793e\u88fd\u30c7\u30e5\u30a2\u30eb\u30d9\u30c3\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u6bd4\u8f03\u3057\u3066\u3082\u540c\u7b49\u4ee5\u4e0a\u306e\u7cbe\u5ea6\u30fb\u518d\u73fe\u6027\u304c\u5f97\u3089\u308c\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790\u30c7\u30fc\u30bf\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u304c\u3042\u3089\u304b\u3058\u3081\u5145\u586b\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u76ee\u8a70\u307e\u308a\u304c\u8d77\u3053\u308a\u306b\u304f\u304f\u3001\u518d\u62bd\u51fa\u306e\u5fc5\u8981\u304c\u306a\u3044\u305f\u3081\u3001\u5206\u6790\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u8b1d\u8f9e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u306eSPE\u81ea\u52d5\u5316\u8a55\u4fa1\u306b\u3042\u305f\u308a\u3001PromoChrom SPE-03\u30b7\u30b9\u30c6\u30e0\u3092\u3054\u63d0\u4f9b\u3044\u305f\u3060\u3044\u305fMaryland Spectral Services\u793e(<a href=\"https:\/\/www.mdspectral.com\/\" target=\"_blank\" rel=\"noopener\">https:\/\/www.mdspectral.com\/<\/a>) \u306b\u611f\u8b1d\u7533\u3057\u4e0a\u3052\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u7167\u6587\u732e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. J. Hoisington, \u975e\u98f2\u6599\u6c34\u306ePFAS\u5206\u6790\uff1a\u7c21\u7565\u5316\u3055\u308c\u305fSPE, Application note EVAN4369-, Restek Corporation, 2024. <a href=\"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan4369-ja\/simplified-spe-for-pfas-analysis-of-non-potable-waters-japan\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan4369-ja\/simplified-spe-for-pfas-analysis-of-non-potable-waters-japan<\/a><\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28931\">                                \u30ab\u30bf\u30ed\u30b0No. 28931                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS\u5206\u6790\u7528 \u56fa\u76f8\u62bd\u51fa Resprep PFAS \u30ab\u30fc\u30c8\u30ea\u30c3\u30b8 | \u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u5165\u308a, 6 mL, Filter Aid 2000 mg\/WAX 150 mg\/GCB 50 mg, 30-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28931\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28268\">                                \u30ab\u30bf\u30ed\u30b0No. 28268                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS\u6c34\u9053\u6c34\u5206\u6790 \uff5cResprep WAX\u30dd\u30ea\u30de\u30fcSPE \u30ab\u30fc\u30c8\u30ea\u30c3\u30b8, 30 \u00b5m, 6 mL\/500 mg, 30 \u03bcm, 30-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28268\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30734\">                                \u30ab\u30bf\u30ed\u30b0No. 30734                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u5206\u6790\u7528\u6a19\u6e96\u54c1\uff5cPFAS 28\u6210\u5206\u6df7\u5408 Calibration Standard, 1 \u00b5g\/mL<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30734\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">                                \u30ab\u30bf\u30ed\u30b0No. 9634252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force C18, 1.8 \u00b5m, 50 x 2.1 mm LC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u30ab\u30bf\u30ed\u30b0No. 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS\u5206\u6790\uff5c\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0, 5 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23246\">                                \u30ab\u30bf\u30ed\u30b0No. 23246                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Limited-Volume Screw-Thread Polypropylene Vials, 9 mm, 700 \u00b5L, 12 x 32 mm, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23246\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23247\">                                \u30ab\u30bf\u30ed\u30b0No. 23247                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">2.0 mL, 9 mm Solid-Top Polyethylene Caps, Screw-Thread, 10 mil thick membrane, Clear, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23247\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Key Highlights \u306f\u3058\u3081\u306b\uff1aPFAS\u5206\u6790\u306b\u304a\u3051\u308b\u524d\u51e6\u7406 \u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u306e\u5f79\u5272\uff5e\u81ea\u52d5\u5316\u3078 \u74b0\u5883\u5206\u6790\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u306fPFAS\uff08\u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff09\u5206\u6790\u306e\u8981\u3068\u3044\u3048\u308b\u524d\u51e6\u7406\u6280\u8853\u3067\u3059\u3002\u307b\u3068\u3093\u3069\u306eEPA\u30e1\u30bd\u30c3\u30c9\u3084ASTM\u30e1\u30bd\u30c3\u30c9\u3067\u3082SPE\u306e\u4f7f\u7528\u304c\u898f\u5b9a\u3055\u308c\u3066\u304a\u308a\u3001\u73fe\u5834\u3078\u306e\u666e\u53ca\u5ea6\u306f\u9ad8\u3044\u72b6\u6cc1\u306b\u3042\u308a\u307e\u3059\u3002 SPE\u306f\u30b9\u30c1\u30ec\u30f3-\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\uff08SDVB\uff09\u7cfb\u307e\u305f\u306f\u5f31\u30a2\u30cb\u30aa\u30f3\u4ea4\u63db\uff08WAX\uff09\u7cfb\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u7528\u3044\u3066\u3044\u308b\u306e\u3067\u3001\u6eb6\u5a92\u3092\u5927\u91cf\u306b\u6d88\u8cbb\u3059\u308b\u5206\u6db2\u30ed\u30fc\u30c8\u3084\u9023\u7d9a\u3057\u305f\u6db2-\u6db2\u62bd\u51fa\u3068\u3044\u3063\u305f\u624b\u6cd5\u3092\u4f7f\u308f\u305a\u306b\u3001\u6c34\u6027\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089PFAS\u5316\u5408\u7269\u3092\u52b9\u7387\u7684\u306b\u62bd\u51fa\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001\u56fa\u4f53\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u304a\u3044\u3066\u3082\u3001\u6eb6\u5a92\u62bd\u51fa\u3068\u6c34\u4ea4\u63db\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u5bfe\u5fdc\u304c\u53ef\u80fd\u3067\u3059\u3002\u5f93\u6765\u3001SPE\u306f\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u3067\u624b\u52d5\u64cd\u4f5c\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u30b7\u30b9\u30c6\u30e0\u306e\u81ea\u52d5\u5316\u304c\u9032\u3093\u3067\u3044\u308b\u305f\u3081\u3001\u4f5c\u696d\u52b9\u7387\u304c\u5927\u5e45\u306b\u5411\u4e0a\u3057\u3066\u304d\u3066\u3044\u307e\u3059\u3002 \u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u304b\u3089\u306e\u8131\u5374\uff1aPFAS\u5206\u6790\u306eSPE\u81ea\u52d5\u5316 \u591a\u304f\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u3092\u4f7f\u7528\u3057\u305f\u624b\u52d5SPE\u304c\u60f3\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307b\u3068\u3093\u3069\u306e\u30e1\u30bd\u30c3\u30c9\u306b\u304a\u3044\u3066\u81ea\u52d5SPE\u306b\u3064\u3044\u3066\u306f\u300c\u4f7f\u7528\u53ef\u80fd\u300d\u3068\u8a00\u53ca\u3055\u308c\u308b\u7a0b\u5ea6\u3067\u3059\u304c\u3001\u305d\u308c\u306f\u88c5\u7f6e\u9593\u306e\u4e92\u63db\u6027\u304c\u306a\u3044\u305f\u3081\u3001\u5177\u4f53\u7684\u306a\u5b9f\u88c5\u65b9\u6cd5\u304c\u660e\u8a18\u3067\u304d\u306a\u3044\u304b\u3089\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u81ea\u52d5SPE\u306e\u5c0e\u5165\u65b9\u6cd5\u3068\u3001\u4f7f\u7528\u3059\u308b\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u30e1\u30bd\u30c3\u30c9\u9069\u5408\u6027\u306f\u5404\u30e9\u30dc\u3067\u78ba\u8a8d\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002 \u4ee5\u524d\u306e\u7814\u7a76\u3067\u306f\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u5165\u308a\u306e\u4e8c\u5c64\u5f0fResprep PFAS SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8 (cat.# 28931) \u304cThermo AutoTrace 280 PFAS\u30b7\u30b9\u30c6\u30e0\u3067\u826f\u597d\u306a\u7d50\u679c\u3092\u793a\u3059\u3053\u3068\u304c\u5b9f\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059[1]\u3002\u3053\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001\u30ab\u30fc\u30dc\u30f3\u5c64\u3068WAX\u5c64\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u4e8c\u5c64\u69cb\u9020\uff08\u30c7\u30e5\u30a2\u30eb\u30d9\u30c3\u30c9\uff09\u3092\u63a1\u7528\u3057\u3066\u3044\u308b\u305f\u3081\u3001WAX\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u30ab\u30fc\u30dc\u30f3\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u5225\u3005\u306b\u4f7f\u7528\u3059\u308b\u5834\u5408\u3068\u6bd4\u3079\u3066\u3001\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u3088\u308a\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u8fc5\u901f\u306b\u5b8c\u4e86\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u306f\u51fa\u8377\u6642\u306b\u5145\u586b\u6e08\u307f\u306e\u305f\u3081\u3001\u61f8\u6fc1\u7269\u8cea\u304c\u591a\u304f\u542b\u307e\u308c\u308b\u30b5\u30f3\u30d7\u30eb\u3067\u3082\u76ee\u8a70\u307e\u308a\u3092\u9632\u304e\u30011\u56de\u306e\u62bd\u51fa\u3067\u524d\u51e6\u7406\u304c\u5b8c\u4e86\u3057\u307e\u3059\u3002 \u4eca\u56de\u306e\u7814\u7a76\u3067\u3001Resprep PFAS SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u8907\u6570\u306e\u7af6\u5408\u4ed6\u793e\u88fd\u30c7\u30e5\u30a2\u30eb\u30d9\u30c3\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3001\u304a\u3088\u3073\u5358\u5c64WAX\u5c02\u7528\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u306e\u6027\u80fd\u6bd4\u8f03\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u81ea\u52d5\u5316\u306b\u4f7f\u7528\u3057\u305f\u306e\u306fPromoChrom\u793e\u306eSPE-03\u30b7\u30b9\u30c6\u30e0\u3067\u3001\u3053\u308c\u306f\u4ee5\u524d\u306e\u7814\u7a76\u3067\u4f7f\u7528\u3057\u305f\u3082\u306e\u3068\u306f\u7570\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u30d7\u30ed\u30b0\u30e9\u30e0\u53ef\u80fd\u306a\u7d71\u5408\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3001\u30dc\u30c8\u30eb\u30ea\u30f3\u30b9\u6a5f\u80fd\u3001\u305d\u3057\u3066\u30b3\u30f3\u30d1\u30af\u30c8\u306a\u8a2d\u7f6e\u9762\u7a4d\u3068\u3044\u3063\u305f\u5229\u4fbf\u6027\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306e\u7814\u7a76\u76ee\u7684\u306f2\u3064\u3067\u3059\u3002\u2460SPE-03\u88c5\u7f6e\u3068\u306e\u4e92\u63db\u6027\u78ba\u8a8d\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u78ba\u7acb\u3001\u2461\u5404\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u6027\u80fd\u6bd4\u8f03\u3067\u3059\u3002 \u81ea\u52d5\u5316\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3078\u306e\u30e1\u30bd\u30c3\u30c9\u79fb\u7ba1 PFAS\u5206\u6790\u306eSPE\u3092\u81ea\u52d5\u5316\u3059\u308b\u969b\u306b\u307e\u305a\u8ab2\u984c\u3068\u306a\u308b\u306e\u306f\u3001\u30e1\u30bd\u30c3\u30c9\u306b\u8a18\u8f09\u3055\u308c\u305f\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u306e\u64cd\u4f5c\u624b\u9806\u3092SPE\u88c5\u7f6e\u306b\u5909\u63db\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u591a\u304f\u306e\u88c5\u7f6e\u3067\u306f\u3001SPE\u30d7\u30ed\u30bb\u30b9\u3092\u30b9\u30c6\u30c3\u30d7\u3054\u3068\u306b\u8a73\u7d30\u306b\u8a18\u8ff0\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u305f\u3081\u3001\u30d0\u30ad\u30e5\u30fc\u30e0\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u3092\u4f7f\u3046\u5834\u5408\u3088\u308a\u3082\u624b\u9806\u304c\u8907\u96d1\u306b\u898b\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u5404\u30b9\u30c6\u30c3\u30d7\u306e\u610f\u5473\u3092\u7406\u89e3\u3057\u3066\u3057\u307e\u3048\u3070\u3001\u81ea\u52d5\u5316\u30e1\u30bd\u30c3\u30c9\u3078\u306e\u79fb\u884c\u306f\u6bd4\u8f03\u7684\u30b9\u30e0\u30fc\u30ba\u306b\u9032\u3081\u3089\u308c\u307e\u3059\u3002\u672c\u7814\u7a76\u3067\u4f7f\u7528\u3057\u305fPromoChrom\u30e1\u30bd\u30c3\u30c9\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u3092Table I\u306b\u793a\u3057\u307e\u3059\u3002 Table I: PFAS\u5206\u6790SPE\u81ea\u52d5\u5316\u306e\u305f\u3081\u306ePromoChrom SPE-03\u30d1\u30e9\u30e1\u30fc\u30bf (EPA Method 1633\u6e96\u62e0) \u4f5c\u696d Inlet 1(\u6eb6\u5a92\/\u30b5\u30f3\u30d7\u30eb) Inlet 2(\u30a8\u30a2\u6bd4\u7387) \u6d41\u901f(mL\/min) \u5bb9\u91cf (mL) \u6642\u9593 Waste 2\u306b\u6eb6\u51fa 1% \u30a2\u30f3\u30e2\u30cb\u30a2\u542b\u6709\u30e1\u30bf\u30ce\u30fc\u30eb \u00a0 8 15 \u00a0 Waste 1\u306b\u6eb6\u51fa 0.3 M \u30ae\u9178\u6c34\u6eb6\u6db2 \u00a0 8 5&#8230;<\/p>\n","protected":false},"author":27,"featured_media":91086,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[2760],"industries-application":[2288,2271,2287],"post-badge":[2752],"resource-type":[],"product-library":[2582,2555],"resource-technique":[2346],"ppma_author":[447,451],"class_list":["post-92832","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja","post-badge-new","product-library-spe-sle-ja","product-library-sample-preparation-products-ja","resource-technique-solid-phase-extraction-spe-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"post-badge":[{"value":2752,"label":"New"}],"product-library":[{"value":2582,"label":"SPE\uff5cSLE"},{"value":2555,"label":"\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406"}],"resource-technique":[{"value":2346,"label":"\u56fa\u76f8\u62bd\u51fa (SPE)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-evar5645-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Jason Hoisington","author_link":"https:\/\/discover.restek.com\/ja\/author\/jason-hoisington\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."},{"term_id":451,"user_id":31,"is_guest":0,"slug":"diego-lopez","display_name":"Diego L\u00f3pez","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-lopez-diego.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-lopez-diego.jpg"},"author_category":"1","first_name":"Diego","last_name":"L\u00f3pez","user_url":"https:\/\/www.linkedin.com\/in\/diego-a-lopez\/","job_title":"Product Manager","description":"Diego is the product manager for sample preparation at Restek Corporation. He has over 10 years of experience in liquid chromatography for both chiral and achiral separations and holds a PhD in chemistry from The University of Texas at Arlington."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/92832","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=92832"}],"version-history":[{"count":37,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/92832\/revisions"}],"predecessor-version":[{"id":96019,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/92832\/revisions\/96019"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/91086"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=92832"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=92832"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=92832"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=92832"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=92832"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=92832"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=92832"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=92832"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=92832"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}