{"id":94106,"date":"2025-12-30T18:45:22","date_gmt":"2025-12-30T18:45:22","guid":{"rendered":"https:\/\/discover.restek.com\/?p=94106"},"modified":"2026-05-22T01:45:13","modified_gmt":"2026-05-22T01:45:13","slug":"automating-spe-for-pfas-extraction-ja-2","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan5394-ja\/automating-spe-for-pfas-extraction-ja-2","title":{"rendered":"\u98f2\u6599\u6c34\u4e2d\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306eLC-MS\/MS\u5206\u6790\uff5cBPA\u30fbBPB\u30fbBPS\u30bf\u30fc\u30b2\u30c3\u30c8\u30e1\u30bd\u30c3\u30c9\u53ca\u307315\u7a2e\u985e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u4e00\u6589\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Key Highlights<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u98f2\u6599\u6c34\u4e2d\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u3068\u6b63\u78ba\u306a\u5b9a\u91cf\u3092\u5b9f\u73fe\u3059\u308b\u3001\u8fc5\u901f\u304b\u3064\u7c21\u4fbf\u306a\u30c0\u30a4\u30ec\u30af\u30c8\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u30e1\u30bd\u30c3\u30c9\u3092<strong>2\u7a2e\u985e<\/strong>\u958b\u767a<\/li>\n\n\n\n<li>EU\u6307\u4ee4\u306e\u611f\u5ea6\u8981\u4ef6\uff08LLOQ\uff1a2.5 \u00b5g\/L\uff09\u3092\u6e80\u305f\u3059\u3001<strong>\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u30fbB\u30fbS\uff08BPA\u3001BPB\u3001BPS\uff09\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u6e2c\u5b9a\u30e1\u30bd\u30c3\u30c9<\/strong><\/li>\n\n\n\n<li>\u898f\u5236\u5909\u66f4\u3092\u898b\u636e\u3048\u3066\u5206\u6790\u5bfe\u8c61\u30ea\u30b9\u30c8\u306e\u62e1\u5145\u3092\u691c\u8a0e\u3057\u3066\u3044\u308b\u30e9\u30dc\u306b\u5bfe\u5fdc\u3057\u305f\u3001<strong>15\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u306e\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u8981\u7d04\uff1a\u98f2\u6599\u6c34\u4e2d\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306e\u9ad8\u611f\u5ea6\u30fb\u9ad8\u901f\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306f\u30dd\u30ea\u30ab\u30fc\u30dc\u30cd\u30fc\u30c8\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3084\u30a8\u30dd\u30ad\u30b7\u6a39\u8102\u306e\u88fd\u9020\u306b\u5e83\u304f\u4f7f\u7528\u3055\u308c\u308b\u5408\u6210\u5316\u5b66\u7269\u8cea\u3067\u3042\u308a\u3001\u74b0\u5883\u6c5a\u67d3\u7269\u8cea\u3068\u3057\u3066\u5e83\u304f\u5206\u5e03\u3057\u3066\u3044\u307e\u3059\u3002\u30a8\u30b9\u30c8\u30ed\u30b2\u30f3\u3068\u985e\u4f3c\u3057\u305f\u69cb\u9020\u3092\u6301\u3064\u305f\u3081\u3001\u5185\u5206\u6ccc\u304b\u304f\u4e71\u7269\u8cea\u3068\u3057\u3066\u4f5c\u7528\u3057\u3001\u98f2\u6599\u6c34\u4e2d\u3067\u306e\u691c\u51fa\u304c\u61f8\u5ff5\u3055\u308c\u3066\u3044\u307e\u3059\u3002BPA\u30d5\u30ea\u30fc\u88fd\u54c1\u306b\u4ee3\u66ff\u7269\u8cea\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u308bBPS\u3084BPB\u3082\u3001\u5065\u5eb7\u30ea\u30b9\u30af\u3092\u3082\u305f\u3089\u3059\u53ef\u80fd\u6027\u304c\u6307\u6458\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u3053\u3067\u672c\u7814\u7a76\u3067\u306f\u3001EU\u898f\u5236\u306b\u9069\u5408\u3057\u305fBPA\u3001BPB\u3001BPS\u306e\u9ad8\u901f\u304b\u3064\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u6e2c\u5b9a\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u300115\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u5316\u5408\u7269\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u3001\u98f2\u6599\u6c34\u306e\u6c5a\u67d3\u691c\u67fb\u3092\u5e45\u5e83\u304f\u5b9f\u65bd\u3059\u308b\u30e9\u30dc\u306b\u5bfe\u3057\u3066\u5b9f\u7528\u7684\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b\uff1aEU\u98f2\u6599\u6c34\u6307\u4ee4\u5bfe\u5fdc\uff5c\u98f2\u6599\u6c34\u4e2dBPA\u3001BPB\u3001BPS\u306eLC-MS\/MS\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306f\u98df\u54c1\u3084\u74b0\u5883\u4e2d\u306b\u6c5a\u67d3\u7269\u8cea\u3068\u3057\u3066\u691c\u51fa\u3055\u308c\u308b\u5408\u6210\u5316\u5b66\u7269\u8cea\u3067\u3059\u3002\u4e3b\u306b\u30dd\u30ea\u30ab\u30fc\u30dc\u30cd\u30fc\u30c8\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3084\u30a8\u30dd\u30ad\u30b7\u6a39\u8102\u306e\u88fd\u9020\u306b\u4f7f\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u4e16\u754c\u7684\u306a\u88fd\u9020\u30fb\u4f7f\u7528\u306e\u5e83\u304c\u308a\u304b\u3089\u3001\u74b0\u5883\u3084\u98f2\u6599\u6c34\u3078\u306e\u6df7\u5165\u304c\u61f8\u5ff5\u3055\u308c\u3066\u3044\u307e\u3059\u30022011\u5e74\u306bNational Institutes of Health\uff08NIH\uff09\u304c\u767a\u8868\u3057\u305f\u7814\u7a76\u3067\u306f\u3001\u5bfe\u8c61\u8005427\u540d\u306e\u3046\u306191%\u306e\u5c3f\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u304c\u691c\u51fa\u3055\u308c\u3066\u3044\u307e\u3059 [1]\u3002\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306f2\u3064\u306e\u30d5\u30a7\u30ce\u30fc\u30eb\u57fa\u304c\u67b6\u6a4b\u57fa\u306b\u3088\u3063\u3066\u7d50\u5408\u3057\u305f\u5171\u901a\u69cb\u9020\u3092\u6301\u3061\u3001\u30a8\u30b9\u30c8\u30ed\u30b2\u30f3\u3068\u985e\u4f3c\u3057\u305f\u3053\u306e\u69cb\u9020\u306b\u3088\u308a\u3001\u30db\u30eb\u30e2\u30f3\u6a5f\u80fd\u3092\u6a21\u5023\u30fb\u5f71\u97ff\u3057\u3001\u5185\u5206\u6ccc\u304b\u304f\u4e71\u7269\u8cea\u306b\u5206\u985e\u3055\u308c\u307e\u3059 [2]\u3002\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u4eba\u4f53\u3078\u306e\u5f71\u97ff\u304c\u6307\u6458\u3055\u308c\u3066\u3044\u308b\u5316\u5408\u7269\u3067\u3042\u308a\u3001\u7279\u306b<strong>\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\uff08BPA\uff09<\/strong>\u306b\u5bfe\u3057\u3066\u306f\u3001\u98df\u54c1\u63a5\u89e6\u6750\u6599\u3084\u5b50\u3069\u3082\u5411\u3051\u73a9\u5177\u306b\u304a\u3051\u308b\u4f7f\u7528\u898f\u5236\u30fb\u7981\u6b62\u306b\u5411\u3051\u305f\u52d5\u304d\u304c\u5404\u56fd\u898f\u5236\u5f53\u5c40\u3067\u9032\u3093\u3067\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u90e8\u306e\u5730\u57df\u3067\u306f\u898f\u5236\u304c\u6574\u5099\u3055\u308c\u3066\u3044\u308b\u3082\u306e\u306e\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u304a\u3088\u3073\u305d\u306e\u8a98\u5c0e\u4f53\u306f\u591a\u7a2e\u591a\u69d8\u306a\u88fd\u54c1\u306b\u5927\u91cf\u306b\u4f7f\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u74b0\u5883\u7d4c\u8def\u3092\u901a\u3058\u3066\u4f9b\u7d66\u3055\u308c\u308b\u6c34\u3078\u306e\u6df7\u5165\u30ea\u30b9\u30af\u304c\u9ad8\u3044\u72b6\u6cc1\u306b\u3042\u308a\u307e\u3059\u3002<strong>\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebS\uff08BPS\uff09<\/strong>\u306f\u300cBPA\u30d5\u30ea\u30fc\u300d\u88fd\u54c1\u306b\u304a\u3044\u3066BPA\u306e\u4ee3\u66ff\u7269\u8cea\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u5065\u5eb7\u4e0a\u306e\u61f8\u5ff5\u3082\u5831\u544a\u3055\u308c\u3066\u304a\u308a\u3001\u30ab\u30ea\u30d5\u30a9\u30eb\u30cb\u30a2\u5ddeProposition 65\u3067\u306f\u751f\u6b96\u6bd2\u6027\u7269\u8cea\u306b\u6307\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059 [3]\u3002<strong>\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebB\uff08BPB\uff09<\/strong>\u306fBPA\u304a\u3088\u3073BPS\u306e\u4ee3\u66ff\u7269\u8cea\u3068\u3057\u3066\u6d88\u8cbb\u8ca1\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u540c\u69d8\u306b\u5185\u5206\u6ccc\u304b\u304f\u4e71\u4f5c\u7528\u304c\u61f8\u5ff5\u3055\u308c\u3066\u3044\u307e\u3059 [4]\u3002\u6b27\u5dde\u9023\u5408\uff08EU\uff09\u306e\u98f2\u6599\u6c34\u6307\u4ee4\u3067\u306f2026\u5e741\u6708\u307e\u3067\u306b\u3001\u98f2\u6599\u6c34\u4e2d\u306e<strong>\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA<\/strong>\u6fc3\u5ea6\u3092\u57fa\u6e96\u50242.5 \u00b5g\/L\u4ee5\u4e0b\u306b\u7ba1\u7406\u3059\u308b\u3053\u3068\u304c\u6c34\u9053\u4e8b\u696d\u8005\u306b\u7fa9\u52d9\u4ed8\u3051\u3089\u308c\u3066\u3044\u307e\u3059 [5]\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u306f\u3001\u98f2\u6599\u6c34\u4e2d\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306e\u30c0\u30a4\u30ec\u30af\u30c8\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u3092<strong>2\u7a2e\u985e<\/strong>\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u6700\u3082\u5206\u6790\u983b\u5ea6\u306e\u9ad8\u3044<strong>\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u9ad8\u901f\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30e1\u30bd\u30c3\u30c9<\/strong>\u306f\u3001EU\u98f2\u6599\u6c34\u6307\u4ee4\u306b\u9069\u5408\u3057\u3066\u304a\u308a\u3001\u6dfb\u52a0\u6c34\u30b5\u30f3\u30d7\u30eb\u3092\u7528\u3044\u305f\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027\u306e\u8a55\u4fa1\u3082\u5b9f\u65bd\u6e08\u307f\u3067\u3059\u3002\u307e\u305f\u3001\u4eca\u5f8c\u306e\u898f\u5236\u5909\u66f4\u3092\u898b\u636e\u3048\u305f\u5148\u884c\u7684\u306a\u5bfe\u5fdc\u3068\u3057\u3066\u3001<strong>15\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u5316\u5408\u7269\u306e\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9<\/strong>\u3082\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u672c\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u6c5a\u67d3\u691c\u67fb\u306e\u5c0e\u5165\u30fb\u62e1\u5145\u3092\u691c\u8a0e\u3057\u3066\u3044\u308b\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001\u98f2\u6599\u6c34\u4e2d\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u5206\u6790\u306b\u304a\u3051\u308b\u9ad8\u901f\u304b\u3064\u7c21\u4fbf\u306a\u624b\u6cd5\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u9a13<\/h2>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-1\" style=\"font-size:22px\">\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305fLC-MS\/MS\u30e1\u30bd\u30c3\u30c9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u6761\u4ef6\u3092<strong>Table I<\/strong>\u306b\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u3068\u5185\u90e8\u6a19\u6e96\u306eMS\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\u3092<strong>Table II<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u306e\u5206\u6790\u6761\u4ef6<\/p>\n\n\n<p><style>\n.cond-table{width:100%;border-collapse:collapse;font-size:13px}\n.cond-table th,.cond-table td{padding:6px 10px;border:1px solid #ddd;vertical-align:middle}\n.cond-table th{background:#f5f5f5;font-weight:600;width:130px;white-space:nowrap;color:#444}\n.grad-table{border-collapse:collapse;font-size:12px}\n.grad-table th,.grad-table td{padding:3px 10px;border:1px solid #ddd;text-align:center}\n.grad-table th{background:#f5f5f5;font-weight:600;color:#444}\n<\/style><\/p>\n<table class=\"cond-table\">\n<tbody>\n<tr>\n<th>\u30ab\u30e9\u30e0<\/th>\n<td>Raptor Biphenyl 50 x 3.0 mm, 2.7 \u03bcm (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/9309A5E\" target=\"_blank\" rel=\"noopener\">9309A5E<\/a>)<\/td>\n<\/tr>\n<tr>\n<th>\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0<\/th>\n<td>Raptor Biphenyl EXP guard column cartridge 5 x 3.0 mm, 2.7 \u03bcm (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/9309A0253\" target=\"_blank\" rel=\"noopener\">9309A0253<\/a>)<\/td>\n<\/tr>\n<tr>\n<th>\u30ab\u30e9\u30e0\u6e29\u5ea6<\/th>\n<td>30 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>\u6ce8\u5165\u91cf<\/th>\n<td>10 \u03bcL<\/td>\n<\/tr>\n<tr>\n<th>\u79fb\u52d5\u76f8 A<\/th>\n<td>\u6c34<\/td>\n<\/tr>\n<tr>\n<th>\u79fb\u52d5\u76f8 B<\/th>\n<td>\u30e1\u30bf\u30ce\u30fc\u30eb<\/td>\n<\/tr>\n<tr>\n<th>\u6d41\u91cf<\/th>\n<td>0.8 mL\/min<\/td>\n<\/tr>\n<tr>\n<th>\u691c\u51fa\u5668<\/th>\n<td>ESI (-) MS\/MS<\/td>\n<\/tr>\n<tr>\n<th>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/th>\n<td>\n<table class=\"grad-table\">\n<tbody>\n<tr>\n<th>\u6642\u9593 (min)<\/th>\n<th>%B<\/th>\n<\/tr>\n<tr>\n<td>0.00<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>0.50<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>3.50<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>3.51<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>5.00<\/td>\n<td>40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<th>\u5ec3\u6db2\u5207\u66ff<\/th>\n<td>0.00 min<\/td>\n<\/tr>\n<tr>\n<th>MS\u5207\u66ff<\/th>\n<td>0.80 min<\/td>\n<\/tr>\n<tr>\n<th>\u5ec3\u6db2\u5207\u66ff<\/th>\n<td>3.51 min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<strong>Table II:<\/strong> \u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u306eMS\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3<\/p>\n\n\n<p><style>\n.mrm-table{width:100%;border-collapse:collapse;font-size:13px}\n.mrm-table th,.mrm-table td{padding:6px 10px;border:1px solid #ddd;text-align:center;vertical-align:middle}\n.mrm-table th{background:#f5f5f5;font-weight:600;color:#444}\n.mrm-table td{color:#333}\n.mrm-table td:first-child{text-align:left}\n<\/style><\/p>\n<table class=\"mrm-table\">\n<tbody>\n<tr>\n<th>\u5206\u6790\u5bfe\u8c61\u6210\u5206<\/th>\n<th>\u30d7\u30ec\u30ab\u30fc\u30b5<\/th>\n<th>\u30d7\u30ed\u30c0\u30af\u30c8 1<\/th>\n<th>\u30d7\u30ed\u30c0\u30af\u30c8 2<\/th>\n<th>\u5185\u90e8\u6a19\u6e96<\/th>\n<\/tr>\n<tr>\n<td>Bisphenol S<\/td>\n<td>249.00<\/td>\n<td>108.15<\/td>\n<td>92.10<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol A<\/td>\n<td>227.00<\/td>\n<td>212.05<\/td>\n<td>133.25<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol B<\/td>\n<td>241.00<\/td>\n<td>212.05<\/td>\n<td>211.10<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol A-d16<\/td>\n<td>241.00<\/td>\n<td>223.25<\/td>\n<td>&#8211;<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol S-d8<\/td>\n<td>257.00<\/td>\n<td>112.20<\/td>\n<td>&#8211;<\/td>\n<td>1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-2\" style=\"font-size:22px\">15\u7a2e\u985e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u306e\u5305\u62ec\u7684LC-MS\/MS\u30e1\u30bd\u30c3\u30c9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u6761\u4ef6\u3092<strong>Table III<\/strong>\u306b\u300115\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u3068\u5185\u90e8\u6a19\u6e96\u306eMS\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\u3092<strong>Table IV<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> 15\u7a2e\u985e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u306e\u5206\u6790\u6761\u4ef6<\/p>\n\n\n<p><style>\n.cond-table2{width:100%;border-collapse:collapse;font-size:13px}\n.cond-table2 th,.cond-table2 td{padding:6px 10px;border:1px solid #ddd;vertical-align:middle}\n.cond-table2 th{background:#f5f5f5;font-weight:600;width:130px;white-space:nowrap;color:#444}\n.grad-table2{border-collapse:collapse;font-size:12px}\n.grad-table2 th,.grad-table2 td{padding:3px 10px;border:1px solid #ddd;text-align:center}\n.grad-table2 th{background:#f5f5f5;font-weight:600;color:#444}\n<\/style><\/p>\n<table class=\"cond-table2\">\n<tbody>\n<tr>\n<th>\u30ab\u30e9\u30e0<\/th>\n<td>Raptor Biphenyl 50 x 3.0 mm, 2.7 \u03bcm (cat.# \u00a0<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/9309A5E\" target=\"_blank\" rel=\"noopener\">9309A5E<\/a>)<\/td>\n<\/tr>\n<tr>\n<th>\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0<\/th>\n<td>Raptor Biphenyl EXP guard column cartridge 5 x 3.0 mm, 2.7 \u03bcm (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/9309A0253\" target=\"_blank\" rel=\"noopener\">9309A0253<\/a>)<\/td>\n<\/tr>\n<tr>\n<th>\u30ab\u30e9\u30e0\u6e29\u5ea6<\/th>\n<td>30 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>\u6ce8\u5165\u91cf<\/th>\n<td>10 \u03bcL<\/td>\n<\/tr>\n<tr>\n<th>\u79fb\u52d5\u76f8 A<\/th>\n<td>\u6c34<\/td>\n<\/tr>\n<tr>\n<th>\u79fb\u52d5\u76f8 B<\/th>\n<td>\u30e1\u30bf\u30ce\u30fc\u30eb<\/td>\n<\/tr>\n<tr>\n<th>\u6d41\u91cf<\/th>\n<td>0.8 mL\/min<\/td>\n<\/tr>\n<tr>\n<th>\u691c\u51fa\u5668<\/th>\n<td>ESI (-) MS\/MS<\/td>\n<\/tr>\n<tr>\n<th>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/th>\n<td>\n<table class=\"grad-table2\">\n<tbody>\n<tr>\n<th>\u6642\u9593 (min)<\/th>\n<th>%B<\/th>\n<\/tr>\n<tr>\n<td>0.00<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>1.00<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>6.50<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>7.00<\/td>\n<td>85<\/td>\n<\/tr>\n<tr>\n<td>7.01<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>8.50<\/td>\n<td>40<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<th>\u5ec3\u6db2\u5207\u66ff<\/th>\n<td>0.00 min<\/td>\n<\/tr>\n<tr>\n<th>MS\u5207\u66ff<\/th>\n<td>1.00 min<\/td>\n<\/tr>\n<tr>\n<th>\u5ec3\u6db2\u5207\u66ff<\/th>\n<td>7.00 min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table IV:<\/strong> \u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d15\u7a2e\u985e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u306eMS\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3<\/p>\n\n\n<p><style>\n.mrm-table2{width:100%;border-collapse:collapse;font-size:13px}\n.mrm-table2 th,.mrm-table2 td{padding:6px 10px;border:1px solid #ddd;text-align:center;vertical-align:middle}\n.mrm-table2 th{background:#f5f5f5;font-weight:600;color:#444}\n.mrm-table2 td{color:#333}\n.mrm-table2 td:first-child{text-align:left}\n<\/style><\/p>\n<table class=\"mrm-table2\">\n<tbody>\n<tr>\n<th>\u5206\u6790\u5bfe\u8c61\u6210\u5206<\/th>\n<th>\u30d7\u30ec\u30ab\u30fc\u30b5<\/th>\n<th>\u30d7\u30ed\u30c0\u30af\u30c8 1<\/th>\n<th>\u30d7\u30ed\u30c0\u30af\u30c8 2<\/th>\n<th>\u5185\u90e8\u6a19\u6e96<\/th>\n<\/tr>\n<tr>\n<td>Bisphenol S-d8<\/td>\n<td>257.00<\/td>\n<td>112.20<\/td>\n<td>&#8211;<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol S<\/td>\n<td>249.00<\/td>\n<td>108.15<\/td>\n<td>92.10<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol F<\/td>\n<td>199.00<\/td>\n<td>93.10<\/td>\n<td>104.85<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol E<\/td>\n<td>213.00<\/td>\n<td>197.10<\/td>\n<td>119.05<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol A-d16<\/td>\n<td>241.00<\/td>\n<td>223.25<\/td>\n<td>&#8211;<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol A<\/td>\n<td>227.00<\/td>\n<td>212.05<\/td>\n<td>133.25<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol AF<\/td>\n<td>335.00<\/td>\n<td>265.05<\/td>\n<td>177.20<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol B<\/td>\n<td>241.00<\/td>\n<td>212.05<\/td>\n<td>211.10<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol C<\/td>\n<td>255.00<\/td>\n<td>240.15<\/td>\n<td>147.20<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol AP<\/td>\n<td>289.00<\/td>\n<td>274.15<\/td>\n<td>273.15<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol Z<\/td>\n<td>267.00<\/td>\n<td>173.15<\/td>\n<td>223.10<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol G<\/td>\n<td>311.00<\/td>\n<td>296.30<\/td>\n<td>295.00<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol FL<\/td>\n<td>349.00<\/td>\n<td>256.15<\/td>\n<td>215.20<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol BP<\/td>\n<td>351.00<\/td>\n<td>274.15<\/td>\n<td>273.15<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol M<\/td>\n<td>345.00<\/td>\n<td>251.20<\/td>\n<td>330.20<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol P-13C4<\/td>\n<td>349.00<\/td>\n<td>333.20<\/td>\n<td>&#8211;<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol P<\/td>\n<td>345.00<\/td>\n<td>330.15<\/td>\n<td>315.15<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>Bisphenol PH<\/td>\n<td>379.00<\/td>\n<td>364.10<\/td>\n<td>209.15<\/td>\n<td>3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-3\" style=\"font-size:22px\">\u6a19\u6e96\u8a66\u6599\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u306e\u524d\u51e6\u7406<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985eLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u306e\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u306f\u30012.5\u301c300 \u00b5g\/L\u306e\u6fc3\u5ea6\u7bc4\u56f2\u3067\u4ee5\u4e0b\u306e\u624b\u9806\u306b\u3066\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1 mg\/L\u306e\u540c\u4f4d\u4f53\u6a19\u8b58\u3055\u308c\u305f\u5185\u90e8\u6a19\u6e96\uff08IS\uff0930 \u00b5L\u3092\u4f5c\u696d\u7528\u4e2d\u9593\u6a19\u6e96\u6eb6\u6db2 50 \u00b5L\u304a\u3088\u3073MS\u30b0\u30ec\u30fc\u30c9\u6c34 920 \u00b5L\u3068\u6df7\u5408\u3057\u3001\u8910\u8272\u30d0\u30a4\u30a2\u30eb\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/21142\" target=\"_blank\" rel=\"noreferrer noopener\">21142<\/a>\uff09\u306b\u6dfb\u52a0<\/li>\n\n\n\n<li>5\u7a2e\u985e\u306e\u98f2\u6599\u6c34\u3092\u73fe\u5730\u3067\u63a1\u53d6\u3057\u3001\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027\u306e\u8a55\u4fa1\u306b\u306f\u30011 mL\u306e\u6c34\u30b5\u30f3\u30d7\u30eb\u306b2.5\uff08LLOQ\uff09\u30017.5\uff08LQC\uff09\u300175\uff08MQC\uff09\u00b5g\/L\u306e\u6fc3\u5ea6\u3067\u6dfb\u52a0\u3057\u8abf\u88fd<\/li>\n\n\n\n<li>\u5168\u3066\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u30ad\u30e3\u30c3\u30d7\u3057\u3066\u77ed\u6642\u9593\u306e\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u5f8c\u300110 \u00b5L\u3092LC-MS\/MS\u306b\u6ce8\u5165\u3057\u3066\u5206\u6790<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u679c\u3068\u8003\u5bdf<\/h2>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-4\" style=\"font-size:22px\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u78ba\u7acb\u3057\u305f\u5206\u6790\u6761\u4ef6\u306e\u3082\u3068\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/9309A5E\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Biphenyl\u30ab\u30e9\u30e0<\/a>\u306f\u3001BPA\u30fbBPB\u30fbBPS\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u304a\u3088\u307315\u7a2e\u985e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u306e\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u306e\u3044\u305a\u308c\u306b\u304a\u3044\u3066\u3082\u3001\u5168\u5316\u5408\u7269\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u3092\u9054\u6210\u3057\u307e\u3057\u305f\u3002\u5206\u6790\u5bfe\u8c61\u7269\u8cea\u304c\u4ed6\u306e\u6210\u5206\u304b\u3089\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001MS\u306b\u5230\u9054\u3059\u308b\u6642\u70b9\u3067\u306f\u5206\u6790\u5bfe\u8c61\u7269\u8cea\u3060\u3051\u304c\u6eb6\u51fa\u3057\u3066\u3044\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u4ed6\u306e\u6210\u5206\u306b\u3088\u308b\u30a4\u30aa\u30f3\u30b5\u30d7\u30ec\u30c3\u30b7\u30e7\u30f3\u304c\u8d77\u304d\u306b\u304f\u304f\u306a\u308a\u3001\u6b63\u78ba\u306a\u5b9a\u91cf\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001\u5404\u5206\u6790\u5bfe\u8c61\u3092\u6b63\u78ba\u306b\u7a4d\u5206\u3059\u308b\u305f\u3081\u306b\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u3092\u5fc5\u8981\u3068\u3059\u308b\u3001\u3088\u308a\u5b89\u4fa1\u3067\u9078\u629e\u6027\u306e\u4f4e\u3044\u86cd\u5149\u691c\u51fa\u5668\u3078\u306e\u9069\u7528\u3082\u53ef\u80fd\u306b\u3057\u307e\u3059\u30022\u7a2e\u985e\u306eLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u306f\u3044\u305a\u308c\u3082\u30c0\u30a4\u30ec\u30af\u30c8\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u3092\u63a1\u7528\u3057\u3066\u304a\u308a\u3001\u77ed\u3044\u5206\u6790\u6642\u9593\u3067\u9ad8\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304c\u6c42\u3081\u3089\u308c\u308b\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u7dcf\u30b5\u30a4\u30af\u30eb\u6642\u9593\u306f\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb3\u6210\u5206\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u308f\u305a\u304b5\u5206\u300115\u6210\u5206\u5bfe\u8c61\u306e\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u3067\u306f8.5\u5206\u3067\u3059\u3002\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u52b9\u679c\u306e\u4f4e\u6e1b\u304a\u3088\u3073MS\u3078\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6d41\u5165\u91cf\u306e\u524a\u6e1b\u3092\u76ee\u7684\u3068\u3057\u3066\u3001\u5316\u5408\u7269\u6eb6\u51fa\u306e\u524d\u5f8c\u306b\u30c0\u30a4\u30d0\u30fc\u30bf\u30fc\u30d0\u30eb\u30d6\u3092\u4f7f\u7528\u3057\u3001\u6eb6\u51fa\u6db2\u3092\u5ec3\u6db2\u306b\u5207\u308a\u66ff\u3048\u307e\u3057\u305f\u3002\u3053\u306e\u64cd\u4f5c\u306b\u3088\u308a\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u307e\u3067\u306e\u5206\u6790\u53ef\u80fd\u30b5\u30f3\u30d7\u30eb\u6570\u304c\u5897\u52a0\u3057\u3001\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002<strong><br><\/strong><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> \u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u306eLC-MS\/MS\u5206\u6790\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u306fPDF\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0603.png\" alt=\"Bisphenol A, B, and S on Raptor Biphenyl by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0603<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0253<\/li><li>9309A5E<\/li><li>21142<\/li><li>24497<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>BPA<\/li><li>BPB<\/li><li>BPS<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0603.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> 15\u7a2e\u985e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u306e\u5305\u62ec\u7684LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u306fPDF\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0604.png\" alt=\"15 Bisphenols on Raptor Biphenyl by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0604<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0253<\/li><li>9309A5E<\/li><li>21142<\/li><li>24497<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>BPA<\/li><li>BPAF<\/li><li>BPAP<\/li><li>BPB<\/li><li>BPBP<\/li><li>BPC<\/li><li>BPF<\/li><li>BPFL<\/li><li>BPG<\/li><li>BPM<\/li><li>BPPH<\/li><li>BPS<\/li><li>BPZ<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0604.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-5\" style=\"font-size:22px\">\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u52b9\u679c\u306e\u88dc\u6b63\uff5c\u5185\u90e8\u6a19\u6e96\u306e\u6700\u9069\u5316\u306715\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u3092\u6b63\u78ba\u306b\u5b9a\u91cf<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u52b9\u679c\u3092\u88dc\u6b63\u3059\u308b2\u7a2e\u985e\u306e\u540c\u4f4d\u4f53\u6a19\u8b58\u3055\u308c\u305f\u5185\u90e8\u6a19\u6e96\u306e\u4f7f\u7528\u3092\u691c\u8a0e\u3001\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u8a55\u4fa1\u306e\u7d50\u679c\u3001BPA\u30fbBPB \u30fbBPS\u306e3\u6210\u5206\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u826f\u597d\u306a\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u3053\u306e2\u7a2e\u985e\u306e\u5185\u90e8\u6a19\u6e96\u309215\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u3092\u5bfe\u8c61\u3068\u3057\u305f\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u306b\u9069\u7528\u3057\u305f\u3068\u3053\u308d\u3001\u4e2d\u76e4\u304b\u3089\u5f8c\u534a\u306b\u304b\u3051\u3066\u6eb6\u51fa\u3059\u308b\u6210\u5206\u306e\u5b9a\u91cf\u7d50\u679c\u304c\u8a31\u5bb9\u7bc4\u56f2\u3092\u5916\u308c\u308b\u3053\u3068\u304c\u5224\u660e\u3057\u307e\u3057\u305f\u3002\u30d0\u30eb\u30d6\u5207\u66ff\u306e\u6700\u9069\u5316\u306b\u3088\u308a\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebF\u304a\u3088\u3073E\u306e\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u306f\u6539\u5584\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebAF\u3001G\u3001BP\u3001M\u3001P\u3001PH\u306e\u5b9a\u91cf\u7d50\u679c\u306f\u6539\u5584\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u30023\u7a2e\u76ee\u306e\u5185\u90e8\u6a19\u6e96\u3068\u3057\u3066\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebP-<sup>13<\/sup>C4\u3092\u5c0e\u5165\u3057\u305f\u7d50\u679c\u300115\u7a2e\u985e\u5168\u3066\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u3067\u826f\u597d\u306a\u518d\u73fe\u6027\u304a\u3088\u3073\u7cbe\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-6\" style=\"font-size:22px\">\u76f4\u7dda\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">2\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u306f\u3044\u305a\u308c\u3082\u76f4\u7dda\u7684\u306a\u691c\u91cf\u7dda\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u76f4\u7dda\u56de\u5e30\uff081\/x\u91cd\u307f\u4ed8\u3051\uff09\u3092\u7528\u3044\u3066\u5b9a\u91cf\u3057\u305f\u7d50\u679c\u3001<strong>\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S<\/strong>\u306f2.5\u301c300 \u00b5g\/L\u306e\u691c\u91cf\u7bc4\u56f2\u306b\u304a\u3044\u3066r\u00b2\u50240.993\u4ee5\u4e0a\u3001\u504f\u5dee20%\u672a\u6e80\u3068\u826f\u597d\u306a\u76f4\u7dda\u6027\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u3082\u76f4\u7dda\u56de\u5e30\uff081\/x\u91cd\u307f\u4ed8\u3051\uff09\u3092\u7528\u3044\u3066\u5b9a\u91cf\u3057\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebPH\uff085\u301c150 \u00b5g\/L\uff09\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebG\uff085\u301c100 \u00b5g\/L\uff09\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebAF\uff082.5\u301c150 \u00b5g\/L\uff09\u3092\u9664\u304f\u5168\u5316\u5408\u7269\u3067\u30012.5\u301c300 \u00b5g\/L\u306e\u691c\u91cf\u7bc4\u56f2\u306b\u304a\u3044\u3066r\u00b2\u50240.991\u4ee5\u4e0a\u3001\u504f\u5dee20%\u672a\u6e80\u306b\u53ce\u307e\u308a\u3001\u5341\u5206\u306a\u7cbe\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-7\" style=\"font-size:22px\">\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u73fe\u5730\u3067\u63a1\u53d6\u3057\u305f\u98f2\u6599\u6c34\u306b\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u30922.5\uff08LLOQ\uff09\u30017.5\uff08LQC\uff09\u300175\uff08MQC\uff09\u00b5g\/L\u3067\u6dfb\u52a0\u3057\u30013\u65e5\u9593\u306b\u308f\u305f\u3063\u3066\u54043\u30d0\u30c3\u30c1\u3001\u8a089\u56de\u306e\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u7d50\u679c\u3092<strong>Table V<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002\u65e5\u5185\u7cbe\u5ea6\uff08\u56de\u53ce\u7387\uff09\u306f\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u306782.4\u301c113.7%\u3001\u65e5\u9593\u56de\u53ce\u7387\u306f86.6\u301c108.3%\u306e\u7bc4\u56f2\u3067\u3057\u305f\u3002\u518d\u73fe\u6027\uff08%RSD\uff09\u306f\u65e5\u5185\u3067\u226411.2%\u3001\u65e5\u9593\u3067\u22646.6%\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table V:<\/strong> \u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u306e\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027<\/p>\n\n\n<p><style>\n.rec-table{width:100%;border-collapse:collapse;font-size:12px;margin-bottom:2em}\n.rec-table th,.rec-table td{padding:5px 8px;border:1px solid #ddd;text-align:center;vertical-align:middle}\n.rec-table th{background:#f5f5f5;font-weight:600;color:#444}\n.rec-table td:first-child{text-align:left;white-space:nowrap}\n.rec-table .title-row td{background:#e8e8e8;font-weight:700;font-style:italic;text-align:center;font-size:13px}\n.rec-table .group-header{background:#f0f0f0}\n<\/style><\/p>\n<!-- Bisphenol S -->\n<table class=\"rec-table\">\n<tbody>\n<tr>\n<td class=\"title-row\" style=\"font-style: italic;\" colspan=\"13\">Bisphenol S<\/td>\n<\/tr>\n<tr class=\"group-header\">\n<th rowspan=\"2\">\u6c34\u30b5\u30f3\u30d7\u30eb<\/th>\n<th rowspan=\"2\">\u76ee\u6a19\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th colspan=\"3\">Day 1<\/th>\n<th colspan=\"3\">Day 2<\/th>\n<th colspan=\"3\">Day 3<\/th>\n<th colspan=\"2\">\u65e5\u9593<\/th>\n<\/tr>\n<tr class=\"group-header\">\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>Average<\/th>\n<th>%RSD<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"3\">1 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.2<\/td>\n<td>86.8<\/td>\n<td>4.0<\/td>\n<td>2.3<\/td>\n<td>90.6<\/td>\n<td>2.2<\/td>\n<td>2.4<\/td>\n<td>95.7<\/td>\n<td>1.2<\/td>\n<td>91.0<\/td>\n<td>4.9<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.9<\/td>\n<td>106.0<\/td>\n<td>2.5<\/td>\n<td>7.8<\/td>\n<td>103.8<\/td>\n<td>3.6<\/td>\n<td>7.9<\/td>\n<td>105.2<\/td>\n<td>1.5<\/td>\n<td>105.0<\/td>\n<td>1.1<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>78.0<\/td>\n<td>103.9<\/td>\n<td>0.9<\/td>\n<td>75.5<\/td>\n<td>100.7<\/td>\n<td>4.1<\/td>\n<td>76.8<\/td>\n<td>102.4<\/td>\n<td>1.5<\/td>\n<td>102.3<\/td>\n<td>1.6<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">2 \u88fd\u6c37\u6a5f\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.1<\/td>\n<td>84.8<\/td>\n<td>2.9<\/td>\n<td>2.3<\/td>\n<td>91.2<\/td>\n<td>4.3<\/td>\n<td>2.4<\/td>\n<td>95.0<\/td>\n<td>2.9<\/td>\n<td>90.3<\/td>\n<td>5.7<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.6<\/td>\n<td>101.3<\/td>\n<td>5.8<\/td>\n<td>7.9<\/td>\n<td>104.7<\/td>\n<td>2.9<\/td>\n<td>7.8<\/td>\n<td>104.2<\/td>\n<td>1.8<\/td>\n<td>103.4<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>77.6<\/td>\n<td>103.5<\/td>\n<td>5.7<\/td>\n<td>78.7<\/td>\n<td>104.9<\/td>\n<td>3.3<\/td>\n<td>75.7<\/td>\n<td>100.9<\/td>\n<td>1.9<\/td>\n<td>103.1<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">3 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.1<\/td>\n<td>84.0<\/td>\n<td>3.0<\/td>\n<td>2.3<\/td>\n<td>91.1<\/td>\n<td>5.4<\/td>\n<td>2.4<\/td>\n<td>95.8<\/td>\n<td>1.6<\/td>\n<td>90.3<\/td>\n<td>6.6<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.7<\/td>\n<td>102.4<\/td>\n<td>7.4<\/td>\n<td>7.9<\/td>\n<td>105.5<\/td>\n<td>4.7<\/td>\n<td>7.9<\/td>\n<td>105.1<\/td>\n<td>1.2<\/td>\n<td>104.3<\/td>\n<td>1.6<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>80.5<\/td>\n<td>107.3<\/td>\n<td>2.8<\/td>\n<td>80.7<\/td>\n<td>107.6<\/td>\n<td>5.2<\/td>\n<td>77.0<\/td>\n<td>102.6<\/td>\n<td>1.3<\/td>\n<td>105.9<\/td>\n<td>2.6<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">4 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.1<\/td>\n<td>84.6<\/td>\n<td>7.6<\/td>\n<td>2.2<\/td>\n<td>86.3<\/td>\n<td>4.5<\/td>\n<td>2.2<\/td>\n<td>88.9<\/td>\n<td>2.6<\/td>\n<td>86.6<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.6<\/td>\n<td>101.1<\/td>\n<td>2.6<\/td>\n<td>7.3<\/td>\n<td>97.1<\/td>\n<td>4.4<\/td>\n<td>7.4<\/td>\n<td>98.0<\/td>\n<td>6.4<\/td>\n<td>98.7<\/td>\n<td>2.1<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>78.0<\/td>\n<td>103.9<\/td>\n<td>2.2<\/td>\n<td>78.1<\/td>\n<td>104.1<\/td>\n<td>1.9<\/td>\n<td>78.0<\/td>\n<td>104.0<\/td>\n<td>2.0<\/td>\n<td>104.0<\/td>\n<td>0.1<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">5 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.1<\/td>\n<td>82.4<\/td>\n<td>4.4<\/td>\n<td>2.3<\/td>\n<td>92.6<\/td>\n<td>5.3<\/td>\n<td>2.3<\/td>\n<td>91.5<\/td>\n<td>2.4<\/td>\n<td>88.8<\/td>\n<td>6.3<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.6<\/td>\n<td>101.4<\/td>\n<td>4.8<\/td>\n<td>8.1<\/td>\n<td>108.2<\/td>\n<td>2.8<\/td>\n<td>7.6<\/td>\n<td>101.5<\/td>\n<td>2.3<\/td>\n<td>103.7<\/td>\n<td>3.8<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>77.8<\/td>\n<td>103.7<\/td>\n<td>2.0<\/td>\n<td>85.3<\/td>\n<td>113.7<\/td>\n<td>3.9<\/td>\n<td>76.1<\/td>\n<td>101.5<\/td>\n<td>1.9<\/td>\n<td>106.3<\/td>\n<td>6.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- Bisphenol B -->\n<table class=\"rec-table\">\n<tbody>\n<tr>\n<td class=\"title-row\" colspan=\"13\">Bisphenol B<\/td>\n<\/tr>\n<tr class=\"group-header\">\n<th rowspan=\"2\">\u6c34\u30b5\u30f3\u30d7\u30eb<\/th>\n<th rowspan=\"2\">\u76ee\u6a19\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th colspan=\"3\">Day 1<\/th>\n<th colspan=\"3\">Day 2<\/th>\n<th colspan=\"3\">Day 3<\/th>\n<th colspan=\"2\">\u65e5\u9593<\/th>\n<\/tr>\n<tr class=\"group-header\">\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>Average<\/th>\n<th>%RSD<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"3\">1 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.7<\/td>\n<td>106.3<\/td>\n<td>2.6<\/td>\n<td>2.7<\/td>\n<td>106.6<\/td>\n<td>6.5<\/td>\n<td>2.6<\/td>\n<td>102.4<\/td>\n<td>4.7<\/td>\n<td>105.1<\/td>\n<td>2.2<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.3<\/td>\n<td>97.0<\/td>\n<td>2.1<\/td>\n<td>7.3<\/td>\n<td>97.8<\/td>\n<td>2.9<\/td>\n<td>7.0<\/td>\n<td>92.8<\/td>\n<td>4.1<\/td>\n<td>95.9<\/td>\n<td>2.8<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>72.0<\/td>\n<td>96.0<\/td>\n<td>6.6<\/td>\n<td>69.6<\/td>\n<td>92.8<\/td>\n<td>3.4<\/td>\n<td>74.4<\/td>\n<td>99.2<\/td>\n<td>11.2<\/td>\n<td>96.0<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">2 \u88fd\u6c37\u6a5f\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.5<\/td>\n<td>100.1<\/td>\n<td>5.4<\/td>\n<td>2.4<\/td>\n<td>96.3<\/td>\n<td>4.7<\/td>\n<td>2.5<\/td>\n<td>101.4<\/td>\n<td>1.7<\/td>\n<td>99.3<\/td>\n<td>2.7<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.2<\/td>\n<td>95.5<\/td>\n<td>2.3<\/td>\n<td>7.0<\/td>\n<td>93.2<\/td>\n<td>5.3<\/td>\n<td>7.1<\/td>\n<td>94.4<\/td>\n<td>10.6<\/td>\n<td>94.4<\/td>\n<td>1.3<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>69.5<\/td>\n<td>92.7<\/td>\n<td>2.2<\/td>\n<td>65.7<\/td>\n<td>87.6<\/td>\n<td>1.8<\/td>\n<td>70.2<\/td>\n<td>93.7<\/td>\n<td>5.3<\/td>\n<td>91.3<\/td>\n<td>3.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">3 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.5<\/td>\n<td>101.9<\/td>\n<td>3.8<\/td>\n<td>2.7<\/td>\n<td>108.0<\/td>\n<td>0.1<\/td>\n<td>2.7<\/td>\n<td>106.8<\/td>\n<td>3.7<\/td>\n<td>105.6<\/td>\n<td>3.0<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.4<\/td>\n<td>98.1<\/td>\n<td>1.7<\/td>\n<td>7.3<\/td>\n<td>97.2<\/td>\n<td>4.3<\/td>\n<td>7.2<\/td>\n<td>96.2<\/td>\n<td>3.2<\/td>\n<td>97.2<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>68.2<\/td>\n<td>91.0<\/td>\n<td>3.1<\/td>\n<td>71.1<\/td>\n<td>94.8<\/td>\n<td>2.4<\/td>\n<td>72.6<\/td>\n<td>96.8<\/td>\n<td>4.0<\/td>\n<td>94.2<\/td>\n<td>3.2<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">4 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.7<\/td>\n<td>106.4<\/td>\n<td>5.8<\/td>\n<td>2.7<\/td>\n<td>110.0<\/td>\n<td>1.7<\/td>\n<td>2.7<\/td>\n<td>108.6<\/td>\n<td>7.2<\/td>\n<td>108.3<\/td>\n<td>1.7<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.8<\/td>\n<td>104.2<\/td>\n<td>3.1<\/td>\n<td>7.7<\/td>\n<td>103.0<\/td>\n<td>2.3<\/td>\n<td>7.5<\/td>\n<td>100.4<\/td>\n<td>5.6<\/td>\n<td>102.5<\/td>\n<td>1.9<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>79.6<\/td>\n<td>106.1<\/td>\n<td>3.0<\/td>\n<td>72.7<\/td>\n<td>96.9<\/td>\n<td>1.7<\/td>\n<td>71.6<\/td>\n<td>95.5<\/td>\n<td>3.4<\/td>\n<td>99.5<\/td>\n<td>5.8<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">5 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.7<\/td>\n<td>107.7<\/td>\n<td>1.7<\/td>\n<td>2.6<\/td>\n<td>102.4<\/td>\n<td>7.2<\/td>\n<td>2.5<\/td>\n<td>101.7<\/td>\n<td>0.2<\/td>\n<td>103.9<\/td>\n<td>3.1<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.5<\/td>\n<td>100.5<\/td>\n<td>2.6<\/td>\n<td>7.4<\/td>\n<td>99.0<\/td>\n<td>2.5<\/td>\n<td>6.7<\/td>\n<td>89.9<\/td>\n<td>6.0<\/td>\n<td>96.5<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>71.4<\/td>\n<td>95.2<\/td>\n<td>2.4<\/td>\n<td>70.6<\/td>\n<td>94.1<\/td>\n<td>1.9<\/td>\n<td>66.0<\/td>\n<td>88.0<\/td>\n<td>1.7<\/td>\n<td>92.4<\/td>\n<td>4.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- Bisphenol A -->\n<table class=\"rec-table\">\n<tbody>\n<tr>\n<td class=\"title-row\" colspan=\"13\">Bisphenol A<\/td>\n<\/tr>\n<tr class=\"group-header\">\n<th rowspan=\"2\">\u6c34\u30b5\u30f3\u30d7\u30eb<\/th>\n<th rowspan=\"2\">\u76ee\u6a19\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th colspan=\"3\">Day 1<\/th>\n<th colspan=\"3\">Day 2<\/th>\n<th colspan=\"3\">Day 3<\/th>\n<th colspan=\"2\">\u65e5\u9593<\/th>\n<\/tr>\n<tr class=\"group-header\">\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>\u8a08\u7b97\u6fc3\u5ea6<br \/>(\u03bcg\/L)<\/th>\n<th>%<br \/>Recovery<\/th>\n<th>%RSD<\/th>\n<th>Average<\/th>\n<th>%RSD<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"3\">1 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.8<\/td>\n<td>110.1<\/td>\n<td>7.5<\/td>\n<td>2.5<\/td>\n<td>101.0<\/td>\n<td>8.4<\/td>\n<td>2.6<\/td>\n<td>105.1<\/td>\n<td>2.9<\/td>\n<td>105.4<\/td>\n<td>4.3<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.5<\/td>\n<td>100.2<\/td>\n<td>6.4<\/td>\n<td>7.6<\/td>\n<td>102.0<\/td>\n<td>0.9<\/td>\n<td>7.2<\/td>\n<td>96.0<\/td>\n<td>3.9<\/td>\n<td>99.4<\/td>\n<td>3.1<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>72.9<\/td>\n<td>97.1<\/td>\n<td>3.6<\/td>\n<td>71.4<\/td>\n<td>95.2<\/td>\n<td>3.0<\/td>\n<td>76.9<\/td>\n<td>102.6<\/td>\n<td>5.8<\/td>\n<td>98.3<\/td>\n<td>3.9<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">2 \u88fd\u6c37\u6a5f\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.5<\/td>\n<td>99.2<\/td>\n<td>4.3<\/td>\n<td>2.7<\/td>\n<td>107.4<\/td>\n<td>8.1<\/td>\n<td>2.6<\/td>\n<td>103.9<\/td>\n<td>9.4<\/td>\n<td>103.5<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.6<\/td>\n<td>101.6<\/td>\n<td>2.9<\/td>\n<td>7.7<\/td>\n<td>102.4<\/td>\n<td>5.7<\/td>\n<td>7.7<\/td>\n<td>102.3<\/td>\n<td>6.1<\/td>\n<td>102.1<\/td>\n<td>0.4<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>71.3<\/td>\n<td>95.1<\/td>\n<td>4.6<\/td>\n<td>73.6<\/td>\n<td>98.1<\/td>\n<td>3.3<\/td>\n<td>73.8<\/td>\n<td>98.4<\/td>\n<td>1.4<\/td>\n<td>97.2<\/td>\n<td>1.9<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">3 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.7<\/td>\n<td>108.7<\/td>\n<td>7.7<\/td>\n<td>2.6<\/td>\n<td>104.1<\/td>\n<td>1.5<\/td>\n<td>2.5<\/td>\n<td>100.6<\/td>\n<td>4.8<\/td>\n<td>104.5<\/td>\n<td>3.9<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.8<\/td>\n<td>104.0<\/td>\n<td>3.6<\/td>\n<td>7.4<\/td>\n<td>98.2<\/td>\n<td>3.6<\/td>\n<td>7.4<\/td>\n<td>98.7<\/td>\n<td>3.1<\/td>\n<td>100.3<\/td>\n<td>3.2<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>72.6<\/td>\n<td>96.8<\/td>\n<td>2.9<\/td>\n<td>75.5<\/td>\n<td>100.6<\/td>\n<td>4.1<\/td>\n<td>76.5<\/td>\n<td>102.0<\/td>\n<td>3.3<\/td>\n<td>99.8<\/td>\n<td>2.7<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">4 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.6<\/td>\n<td>102.7<\/td>\n<td>5.4<\/td>\n<td>2.5<\/td>\n<td>101.3<\/td>\n<td>3.2<\/td>\n<td>2.6<\/td>\n<td>106.0<\/td>\n<td>8.9<\/td>\n<td>103.3<\/td>\n<td>2.3<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>8.0<\/td>\n<td>107.0<\/td>\n<td>3.4<\/td>\n<td>7.6<\/td>\n<td>100.7<\/td>\n<td>3.5<\/td>\n<td>7.6<\/td>\n<td>101.8<\/td>\n<td>5.3<\/td>\n<td>103.2<\/td>\n<td>3.3<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>75.3<\/td>\n<td>100.4<\/td>\n<td>3.1<\/td>\n<td>75.0<\/td>\n<td>100.0<\/td>\n<td>2.8<\/td>\n<td>73.4<\/td>\n<td>97.8<\/td>\n<td>5.4<\/td>\n<td>99.4<\/td>\n<td>1.4<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">5 \u98f2\u6599\u6c34<\/td>\n<td>2.5<\/td>\n<td>2.5<\/td>\n<td>100.5<\/td>\n<td>6.2<\/td>\n<td>2.7<\/td>\n<td>107.3<\/td>\n<td>3.1<\/td>\n<td>2.5<\/td>\n<td>99.4<\/td>\n<td>3.2<\/td>\n<td>102.4<\/td>\n<td>4.2<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>7.7<\/td>\n<td>102.2<\/td>\n<td>6.1<\/td>\n<td>7.4<\/td>\n<td>98.4<\/td>\n<td>2.5<\/td>\n<td>7.1<\/td>\n<td>94.4<\/td>\n<td>7.7<\/td>\n<td>98.4<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>73.3<\/td>\n<td>97.7<\/td>\n<td>2.1<\/td>\n<td>73.7<\/td>\n<td>98.3<\/td>\n<td>0.2<\/td>\n<td>71.3<\/td>\n<td>95.1<\/td>\n<td>3.9<\/td>\n<td>97.0<\/td>\n<td>1.8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<p class=\"wp-block-paragraph\">\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u306b\u3064\u3044\u3066\u3082\u540c\u69d8\u306b\u300115\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u30922.5\u30017.5\u300175.0 \u00b5g\/L\u306e\u6fc3\u5ea6\u3068\u306a\u308b\u3088\u3046\u306b\u6dfb\u52a0\u3057\u305f\u73fe\u5730\u63a1\u53d6\u98f2\u6599\u6c34\u3092\u7528\u3044\u30013\u65e5\u9593\u30fb\u8a089\u56de\u306e\u5206\u6790\u3067\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u305d\u308c\u305e\u308c\u306e\u7d50\u679c\u306f<strong>Figure 3\u30014\u30015<\/strong>\u306b\u793a\u3057\u307e\u3057\u305f\u304c\u3001\u65e5\u9593\u56de\u53ce\u7387\u306f88.9\u301c115.9%\u3001\u518d\u73fe\u6027\uff08%RSD\uff09\u306f\u226417.3%\uff08n=9\uff09\u3067\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> LLOQ\uff082.5 \u00b5g\/L\uff09\u3067\u306e\u65e5\u9593\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027\uff08n=9\uff09\uff08\u6ce8\uff1a\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebPH\u304a\u3088\u3073G\u306fLLOQ\u304c\u9ad8\u3044\u305f\u3081\u30012.5 \u00b5g\/L\u3067\u306e\u56de\u53ce\u7387\u8a55\u4fa1\u306f\u5b9f\u65bd\u3057\u3066\u3044\u307e\u305b\u3093\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1334\" height=\"538\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-03.jpg\" alt=\"LLQ Recovery (2.5 \u03bcg\/L)\" class=\"wp-image-69984\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-03.jpg 1334w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-03-300x121.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-03-1024x413.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-03-768x310.jpg 768w\" sizes=\"auto, (max-width: 1334px) 100vw, 1334px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4<\/strong>: LQC\uff087.5 \u00b5g\/L\uff09\u3067\u306e\u65e5\u9593\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027\uff08n=9\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"631\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-04.jpg\" alt=\"LQC Recovery (7.5 \u03bcg\/L)\" class=\"wp-image-69990\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-04.jpg 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-04-300x141.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-04-1024x482.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-04-768x362.jpg 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5<\/strong>: MQC\uff0875 \u00b5g\/L\uff09\u3067\u306e\u65e5\u9593\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027\uff08n=9\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"537\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-05.jpg\" alt=\"MQC Recovery (75 \u03bcg\/L)\" class=\"wp-image-69996\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-05.jpg 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-05-300x120.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-05-1024x410.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5394-05-768x308.jpg 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u307e\u3068\u3081\uff1aEU\u98f2\u6599\u6c34\u6307\u4ee4\u5bfe\u5fdc\uff5c\u98f2\u6599\u6c34\u4e2d\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985eLC-MS\/MS\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u306f\u3001\u98f2\u6599\u6c34\u4e2d\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u5206\u6790\u306b\u5bfe\u5fdc\u3059\u308b2\u7a2e\u985e\u306e\u4fe1\u983c\u6027\u306e\u9ad8\u3044LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u3001\u3044\u305a\u308c\u3082\u826f\u597d\u306a\u5b9a\u91cf\u7d50\u679c\u3092\u5f97\u307e\u3057\u305f\u3002\u30c0\u30a4\u30ec\u30af\u30c8\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u63a1\u7528\u306b\u3088\u308a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u7701\u7565\u3057\u3001\u5168\u5316\u5408\u7269\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u3092\u7dad\u6301\u3057\u306a\u304c\u3089\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u3092\u5b9f\u73fe\u3057\u3066\u3044\u307e\u3059\u3002<br>BPA\u30fbBPS\u30fbBPB\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306f3\u6210\u5206\u306e\u8fc5\u901f\u306a\u5b9a\u91cf\u306b\u6700\u9069\u5316\u3055\u308c\u3066\u304a\u308a\u300115\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u306b\u5bfe\u5fdc\u3057\u305f\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u306f\u4eca\u5f8c\u306e\u898f\u5236\u5909\u66f4\u3092\u898b\u636e\u3048\u305f\u5bfe\u8c61\u7269\u8cea\u30ea\u30b9\u30c8\u306e\u62e1\u5145\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u3002\u3044\u305a\u308c\u3082EU\u98f2\u6599\u6c34\u6307\u4ee4\u306e\u611f\u5ea6\u8981\u4ef6\u3092\u6e80\u305f\u3057\u3066\u304a\u308a\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u6c5a\u67d3\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u306e\u5b9f\u7528\u7684\u306a\u30eb\u30fc\u30c1\u30f3\u30e1\u30bd\u30c3\u30c9\u3068\u3057\u3066\u9069\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>X. Ye, L. Wong, A.M. Bishop, A.M. Calafat, Variability of urinary concentrations of bisphenol A in spot samples, first morning voids, and 24-hour collections. Environ Health Perspect, 119 (7) (2011) 983\u2013988. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/21406337\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/pubmed.ncbi.nlm.nih.gov\/21406337\/<\/a><\/li>\n\n\n\n<li>M.E. Cull, L.M. Winn, Bisphenol A and its potential mechanism of action for reproductive toxicity. Toxicology 511 (2025) 154040. <a href=\"https:\/\/doi.org\/10.1016\/j.tox.2024.154040\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.tox.2024.154040<\/a><\/li>\n\n\n\n<li>State of Californai, OEHHA, Bisphenol S (BPS) Added To Proposition 65 List Following 2023 Meeting of The Developmental and Reproductive Toxicant Identification Committee, January 23, 2014. <a href=\"https:\/\/oehha.ca.gov\/proposition-65\/crnr\/bisphenol-s-bps-added-proposition-65-list-following-2023-meeting-developmental-and-reproductive\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/oehha.ca.gov\/proposition-65\/crnr\/bisphenol-s-bps-added-proposition-65-list-following-2023-meeting-developmental-and-reproductive<\/a>. Accessed June 27, 2025.<\/li>\n\n\n\n<li>Bisphenol B, an endocrine disruptor for humans and the environment. Anses. September 3, 2021. <a href=\"https:\/\/www.anses.fr\/en\/content\/bisphenol-b-endocrine-disruptor-humans-and-environment\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.anses.fr\/en\/content\/bisphenol-b-endocrine-disruptor-humans-and-environment<\/a> Accessed June 27, 2015.<\/li>\n\n\n\n<li>Eur Eau position paper : Bisphenol-A and drinking water. Water News Europe, Press Release, April 28, 2025. <a href=\"https:\/\/www.waternewseurope.com\/eureau-position-paper-bisphenol-a-and-drinking-water\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.waternewseurope.com\/eureau-position-paper-bisphenol-a-and-drinking-water\/<\/a> Accessed July 28, 2025.<\/li>\n<\/ol>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A5E\">                                \u30ab\u30bf\u30ed\u30b0No. 9309A5E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl, 2.7 \u00b5m, 50 x 3.0 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A5E\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A0253\">                                \u30ab\u30bf\u30ed\u30b0No. 9309A0253                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 3.0 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A0253\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">                                \u30ab\u30bf\u30ed\u30b0No. 25808                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Direct Connect Holder for EXP Guard Cartridges, Includes Fitting &amp; Ferrules<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21142\">                                \u30ab\u30bf\u30ed\u30b0No. 21142                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap Vial with Grad Marking Spot, 9-425 Screw-Thread, 2.0 mL, 9 mm, 12 x 32 (vial only), Amber, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21142\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24497\">                                \u30ab\u30bf\u30ed\u30b0No. 24497                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short Screw Cap, Polypropylene, Screw-Thread, PTFE\/Silicone\/PTFE Septa, Blue, Preassembled, 2.0 mL, 9 mm, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24497\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Key Highlights \u8981\u7d04\uff1a\u98f2\u6599\u6c34\u4e2d\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306e\u9ad8\u611f\u5ea6\u30fb\u9ad8\u901f\u5206\u6790 \u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306f\u30dd\u30ea\u30ab\u30fc\u30dc\u30cd\u30fc\u30c8\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3084\u30a8\u30dd\u30ad\u30b7\u6a39\u8102\u306e\u88fd\u9020\u306b\u5e83\u304f\u4f7f\u7528\u3055\u308c\u308b\u5408\u6210\u5316\u5b66\u7269\u8cea\u3067\u3042\u308a\u3001\u74b0\u5883\u6c5a\u67d3\u7269\u8cea\u3068\u3057\u3066\u5e83\u304f\u5206\u5e03\u3057\u3066\u3044\u307e\u3059\u3002\u30a8\u30b9\u30c8\u30ed\u30b2\u30f3\u3068\u985e\u4f3c\u3057\u305f\u69cb\u9020\u3092\u6301\u3064\u305f\u3081\u3001\u5185\u5206\u6ccc\u304b\u304f\u4e71\u7269\u8cea\u3068\u3057\u3066\u4f5c\u7528\u3057\u3001\u98f2\u6599\u6c34\u4e2d\u3067\u306e\u691c\u51fa\u304c\u61f8\u5ff5\u3055\u308c\u3066\u3044\u307e\u3059\u3002BPA\u30d5\u30ea\u30fc\u88fd\u54c1\u306b\u4ee3\u66ff\u7269\u8cea\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u308bBPS\u3084BPB\u3082\u3001\u5065\u5eb7\u30ea\u30b9\u30af\u3092\u3082\u305f\u3089\u3059\u53ef\u80fd\u6027\u304c\u6307\u6458\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u3053\u3067\u672c\u7814\u7a76\u3067\u306f\u3001EU\u898f\u5236\u306b\u9069\u5408\u3057\u305fBPA\u3001BPB\u3001BPS\u306e\u9ad8\u901f\u304b\u3064\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u6e2c\u5b9a\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u300115\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u5316\u5408\u7269\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u3001\u98f2\u6599\u6c34\u306e\u6c5a\u67d3\u691c\u67fb\u3092\u5e45\u5e83\u304f\u5b9f\u65bd\u3059\u308b\u30e9\u30dc\u306b\u5bfe\u3057\u3066\u5b9f\u7528\u7684\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002 \u306f\u3058\u3081\u306b\uff1aEU\u98f2\u6599\u6c34\u6307\u4ee4\u5bfe\u5fdc\uff5c\u98f2\u6599\u6c34\u4e2dBPA\u3001BPB\u3001BPS\u306eLC-MS\/MS\u5206\u6790 \u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306f\u98df\u54c1\u3084\u74b0\u5883\u4e2d\u306b\u6c5a\u67d3\u7269\u8cea\u3068\u3057\u3066\u691c\u51fa\u3055\u308c\u308b\u5408\u6210\u5316\u5b66\u7269\u8cea\u3067\u3059\u3002\u4e3b\u306b\u30dd\u30ea\u30ab\u30fc\u30dc\u30cd\u30fc\u30c8\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3084\u30a8\u30dd\u30ad\u30b7\u6a39\u8102\u306e\u88fd\u9020\u306b\u4f7f\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u4e16\u754c\u7684\u306a\u88fd\u9020\u30fb\u4f7f\u7528\u306e\u5e83\u304c\u308a\u304b\u3089\u3001\u74b0\u5883\u3084\u98f2\u6599\u6c34\u3078\u306e\u6df7\u5165\u304c\u61f8\u5ff5\u3055\u308c\u3066\u3044\u307e\u3059\u30022011\u5e74\u306bNational Institutes of Health\uff08NIH\uff09\u304c\u767a\u8868\u3057\u305f\u7814\u7a76\u3067\u306f\u3001\u5bfe\u8c61\u8005427\u540d\u306e\u3046\u306191%\u306e\u5c3f\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u304c\u691c\u51fa\u3055\u308c\u3066\u3044\u307e\u3059 [1]\u3002\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306f2\u3064\u306e\u30d5\u30a7\u30ce\u30fc\u30eb\u57fa\u304c\u67b6\u6a4b\u57fa\u306b\u3088\u3063\u3066\u7d50\u5408\u3057\u305f\u5171\u901a\u69cb\u9020\u3092\u6301\u3061\u3001\u30a8\u30b9\u30c8\u30ed\u30b2\u30f3\u3068\u985e\u4f3c\u3057\u305f\u3053\u306e\u69cb\u9020\u306b\u3088\u308a\u3001\u30db\u30eb\u30e2\u30f3\u6a5f\u80fd\u3092\u6a21\u5023\u30fb\u5f71\u97ff\u3057\u3001\u5185\u5206\u6ccc\u304b\u304f\u4e71\u7269\u8cea\u306b\u5206\u985e\u3055\u308c\u307e\u3059 [2]\u3002\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u4eba\u4f53\u3078\u306e\u5f71\u97ff\u304c\u6307\u6458\u3055\u308c\u3066\u3044\u308b\u5316\u5408\u7269\u3067\u3042\u308a\u3001\u7279\u306b\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\uff08BPA\uff09\u306b\u5bfe\u3057\u3066\u306f\u3001\u98df\u54c1\u63a5\u89e6\u6750\u6599\u3084\u5b50\u3069\u3082\u5411\u3051\u73a9\u5177\u306b\u304a\u3051\u308b\u4f7f\u7528\u898f\u5236\u30fb\u7981\u6b62\u306b\u5411\u3051\u305f\u52d5\u304d\u304c\u5404\u56fd\u898f\u5236\u5f53\u5c40\u3067\u9032\u3093\u3067\u3044\u307e\u3059\u3002 \u4e00\u90e8\u306e\u5730\u57df\u3067\u306f\u898f\u5236\u304c\u6574\u5099\u3055\u308c\u3066\u3044\u308b\u3082\u306e\u306e\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u304a\u3088\u3073\u305d\u306e\u8a98\u5c0e\u4f53\u306f\u591a\u7a2e\u591a\u69d8\u306a\u88fd\u54c1\u306b\u5927\u91cf\u306b\u4f7f\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u74b0\u5883\u7d4c\u8def\u3092\u901a\u3058\u3066\u4f9b\u7d66\u3055\u308c\u308b\u6c34\u3078\u306e\u6df7\u5165\u30ea\u30b9\u30af\u304c\u9ad8\u3044\u72b6\u6cc1\u306b\u3042\u308a\u307e\u3059\u3002\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebS\uff08BPS\uff09\u306f\u300cBPA\u30d5\u30ea\u30fc\u300d\u88fd\u54c1\u306b\u304a\u3044\u3066BPA\u306e\u4ee3\u66ff\u7269\u8cea\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u5065\u5eb7\u4e0a\u306e\u61f8\u5ff5\u3082\u5831\u544a\u3055\u308c\u3066\u304a\u308a\u3001\u30ab\u30ea\u30d5\u30a9\u30eb\u30cb\u30a2\u5ddeProposition 65\u3067\u306f\u751f\u6b96\u6bd2\u6027\u7269\u8cea\u306b\u6307\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059 [3]\u3002\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebB\uff08BPB\uff09\u306fBPA\u304a\u3088\u3073BPS\u306e\u4ee3\u66ff\u7269\u8cea\u3068\u3057\u3066\u6d88\u8cbb\u8ca1\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u540c\u69d8\u306b\u5185\u5206\u6ccc\u304b\u304f\u4e71\u4f5c\u7528\u304c\u61f8\u5ff5\u3055\u308c\u3066\u3044\u307e\u3059 [4]\u3002\u6b27\u5dde\u9023\u5408\uff08EU\uff09\u306e\u98f2\u6599\u6c34\u6307\u4ee4\u3067\u306f2026\u5e741\u6708\u307e\u3067\u306b\u3001\u98f2\u6599\u6c34\u4e2d\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u6fc3\u5ea6\u3092\u57fa\u6e96\u50242.5 \u00b5g\/L\u4ee5\u4e0b\u306b\u7ba1\u7406\u3059\u308b\u3053\u3068\u304c\u6c34\u9053\u4e8b\u696d\u8005\u306b\u7fa9\u52d9\u4ed8\u3051\u3089\u308c\u3066\u3044\u307e\u3059 [5]\u3002 \u672c\u7814\u7a76\u3067\u306f\u3001\u98f2\u6599\u6c34\u4e2d\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306e\u30c0\u30a4\u30ec\u30af\u30c8\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u30922\u7a2e\u985e\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u6700\u3082\u5206\u6790\u983b\u5ea6\u306e\u9ad8\u3044\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305f\u9ad8\u901f\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30e1\u30bd\u30c3\u30c9\u306f\u3001EU\u98f2\u6599\u6c34\u6307\u4ee4\u306b\u9069\u5408\u3057\u3066\u304a\u308a\u3001\u6dfb\u52a0\u6c34\u30b5\u30f3\u30d7\u30eb\u3092\u7528\u3044\u305f\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027\u306e\u8a55\u4fa1\u3082\u5b9f\u65bd\u6e08\u307f\u3067\u3059\u3002\u307e\u305f\u3001\u4eca\u5f8c\u306e\u898f\u5236\u5909\u66f4\u3092\u898b\u636e\u3048\u305f\u5148\u884c\u7684\u306a\u5bfe\u5fdc\u3068\u3057\u3066\u300115\u7a2e\u985e\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u5316\u5408\u7269\u306e\u5305\u62ec\u7684\u30e1\u30bd\u30c3\u30c9\u3082\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u672c\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u6c5a\u67d3\u691c\u67fb\u306e\u5c0e\u5165\u30fb\u62e1\u5145\u3092\u691c\u8a0e\u3057\u3066\u3044\u308b\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001\u98f2\u6599\u6c34\u4e2d\u306e\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30eb\u5206\u6790\u306b\u304a\u3051\u308b\u9ad8\u901f\u304b\u3064\u7c21\u4fbf\u306a\u624b\u6cd5\u3068\u306a\u308a\u307e\u3059\u3002 \u5b9f\u9a13 \u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u3092\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u305fLC-MS\/MS\u30e1\u30bd\u30c3\u30c9 \u5206\u6790\u6761\u4ef6\u3092Table I\u306b\u3001\u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u3068\u5185\u90e8\u6a19\u6e96\u306eMS\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\u3092Table II\u306b\u793a\u3057\u307e\u3059\u3002 Table I: \u30d3\u30b9\u30d5\u30a7\u30ce\u30fc\u30ebA\u3001B\u3001S\u306e\u5206\u6790\u6761\u4ef6 \u30ab\u30e9\u30e0 Raptor Biphenyl 50 x 3.0 mm, 2.7 \u03bcm (cat.# 9309A5E) \u30ac\u30fc\u30c9\u30ab\u30e9\u30e0 Raptor Biphenyl EXP guard column cartridge 5 x 3.0 mm, 2.7 \u03bcm (cat.# 9309A0253) \u30ab\u30e9\u30e0\u6e29\u5ea6 30 \u00b0C&#8230;<\/p>\n","protected":false},"author":47,"featured_media":69983,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[],"industries-application":[2289,2271,2287],"post-badge":[2752],"resource-type":[],"product-library":[2571,2553],"resource-technique":[2365,2343],"ppma_author":[579],"class_list":["post-94106","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja","industries-application-soil-sediment-biota-testing-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja","post-badge-new","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-ms-ms-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}],"industries-application":[{"value":2289,"label":"\u571f\u58cc\uff5c\u5e95\u8cea\uff5c\u751f\u7269\u8a66\u6599 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"post-badge":[{"value":2752,"label":"New"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAN5394-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Jamie L. York, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/jamie-l-york-phd\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":579,"user_id":47,"is_guest":0,"slug":"jamie-l-york-phd","display_name":"Jamie L. York, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg"},"author_category":"1","first_name":"Jamie","last_name":"York","user_url":"https:\/\/www.linkedin.com\/in\/jamielyork\/","job_title":"Principal Scientist, LC Solutions","description":"Jamie York is a principal scientist in the Applications Lab at Restek Corporation. She leads the development of innovative analytical methods tailored to the food, clinical, environmental, and cannabis markets. Jamie earned her PhD in chemistry from The University of Texas at Arlington, where she gained extensive expertise in a range of analytical techniques, including gas chromatography\u2013vacuum ultraviolet (GC\u2013VUV); gas chromatography\u2013mass spectrometry (GC\u2013MS); matrix-assisted laser desorption\/ionization (MALDI); and liquid chromatography\u2013 mass spectrometry (LC\u2013MS\/MS); with a research emphasis on food and environmental analysis. Today, her work focuses on complex method development and advanced sample preparation strategies to support the evolving needs of the scientific community."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94106","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=94106"}],"version-history":[{"count":26,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94106\/revisions"}],"predecessor-version":[{"id":95505,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94106\/revisions\/95505"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/69983"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=94106"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=94106"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=94106"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=94106"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=94106"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=94106"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=94106"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=94106"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=94106"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}