{"id":94281,"date":"2026-03-26T20:24:47","date_gmt":"2026-03-26T20:24:47","guid":{"rendered":"https:\/\/discover.restek.com\/?p=94281"},"modified":"2026-06-04T05:12:26","modified_gmt":"2026-06-04T05:12:26","slug":"rapid-lc-ms-ms-analysis-of-etg-ets-and-barbiturates-in-normal-and-disease-state-urine-presentation-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/posters-presentations-ja\/cfan5245-ja\/rapid-lc-ms-ms-analysis-of-etg-ets-and-barbiturates-in-normal-and-disease-state-urine-presentation-ja","title":{"rendered":"\u5c3f\u4e2dEtG\u30fbEtS\u304a\u3088\u3073\u30d0\u30eb\u30d3\u30c4\u30fc\u30eb\u9178\u985e\u306e\u9ad8\u901fLC-MS\/MS\u5206\u6790\uff5c\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u3092\u78ba\u5b9f\u306b\u5206\u96e2\u3059\u308bForce Biphenyl\u30ab\u30e9\u30e0\u6d3b\u7528\u30e1\u30bd\u30c3\u30c9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u8981\u7d04<\/strong>: \u30a8\u30c1\u30eb\u30b0\u30eb\u30af\u30ed\u30cb\u30c9\uff08EtG\uff09\u304a\u3088\u3073\u30a8\u30c1\u30eb\u30b5\u30eb\u30d5\u30a7\u30fc\u30c8\uff08EtS\uff09\u306f\u3001\u4f53\u5185\u3067\u306e\u30a2\u30eb\u30b3\u30fc\u30eb\u4ee3\u8b1d\u306b\u3088\u3063\u3066\u751f\u6210\u3055\u308c\u308b\u7269\u8cea\u3067\u3042\u308a\u3001\u98f2\u9152\u3092\u5ba2\u89b3\u7684\u306b\u793a\u3059\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3068\u3057\u3066\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306f\u6975\u6027\u304c\u9ad8\u3044\u305f\u3081\u3001\u9006\u76f8\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3088\u308b\u4fdd\u6301\u304c\u96e3\u3057\u304f\u3001\u5206\u6790\u4e0a\u306e\u8ab2\u984c\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u5c3f\u4e2d\u306b\u306f\u5206\u6790\u5bfe\u8c61\u3068\u540c\u4e00\u306e\u8cea\u91cf\u6570\uff08\u540c\u91cd\u4f53\uff09\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u304c\u5b58\u5728\u3059\u308b\u305f\u3081\u3001\u6b63\u78ba\u306a\u30c7\u30fc\u30bf\u3092\u5f97\u308b\u306b\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3088\u3063\u3066\u3053\u308c\u3089\u3092\u78ba\u5b9f\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u306f\u3001\u3053\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u3068\u5206\u6790\u5bfe\u8c61\u3068\u3092\u826f\u597d\u306b\u5206\u96e2\u3067\u304d\u308b\u9ad8\u901fLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u30ab\u30e9\u30e0\u306e\u30d7\u30ec\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u304a\u3053\u306a\u3046\u5fc5\u8981\u306a\u304f\u3001EtG\u304a\u3088\u3073EtS\u3092\u3068\u3082\u306b\u4fdd\u6301\u3057\u306a\u304c\u3089\u5c3f\u4e2d\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u3092\u5b89\u5b9a\u7684\u306b\u5206\u96e2\u3067\u304d\u308b\u3001\u5b9f\u7528\u7684\u306a\u30e1\u30bd\u30c3\u30c9\u3092\u78ba\u7acb\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u306e\u8abf\u88fd\uff1a<\/strong>EtG\u304a\u3088\u3073EtS\u3092\u5408\u6210\u5c3f\u306b\u6dfb\u52a0\u3057\u300150\u301c1,000 ng\/mL\u306e\u6fc3\u5ea6\u7bc4\u56f2\u3067\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002<br><strong>QC\u30b5\u30f3\u30d7\u30eb\u306e\u8abf\u88fd\u3068\u524d\u51e6\u7406\uff1a<\/strong>QC\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u3001\u814e\u75be\u60a3\u304a\u3088\u3073\u809d\u75be\u60a3\u60a3\u8005\u30b5\u30f3\u30d7\u30eb\u3092\u542b\u30806\u30ed\u30c3\u30c8\u306e\u30d2\u30c8\u5c3f\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u30d2\u30c8\u5c3f\u306f0.1%\u30ae\u9178\u3092\u542b\u3080\u6c34\u306720\u500d\u5e0c\u91c8\u3057\u305f\u5f8c\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u304a\u3088\u3073\u9060\u5fc3\u5206\u96e2\u3092\u884c\u3044\u3001\u4e0a\u6e05\u3092<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/962931E\" target=\"_blank\" rel=\"noreferrer noopener\">Force Biphenyl\u30ab\u30e9\u30e0\uff08100 \u00d7 3 mm\u30013 \u00b5m\uff09<\/a>\u306b\u6ce8\u5165\u3057\u307e\u3057\u305f\u3002<br><strong>\u5206\u6790\u6761\u4ef6\uff1a<\/strong>\u79fb\u52d5\u76f8\u306b\u306f0.1%\u30ae\u9178\u3092\u6dfb\u52a0\u3057\u305f\u6c34\u304a\u3088\u3073\u30e1\u30bf\u30ce\u30fc\u30eb\u3092\u4f7f\u7528\u3057\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3067\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u958b\u767a\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u51686\u30ed\u30c3\u30c8\u306eQC\u5c3f\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3044\u3066\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u3068\u5206\u6790\u5bfe\u8c61\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u3092\u9054\u6210\u3057\u3001\u6709\u610f\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5e72\u6e09\u306f\u8a8d\u3081\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u4e21\u5206\u6790\u5bfe\u8c61\u306b\u304a\u3044\u3066r\u00b2\u304c0.99\u4ee5\u4e0a\u306e\u826f\u597d\u306a\u76f4\u7dda\u6027\u304c\u78ba\u8a8d\u3055\u308c\u3001\u65e5\u5185\u304a\u3088\u3073\u65e5\u9593\u3068\u3082\u306b\u8a31\u5bb9\u7bc4\u56f2\u5185\u306e\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9577\u6642\u9593\u306e\u30d7\u30ec\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u5fc5\u8981\u3068\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u30de\u30eb\u30c1\u30e2\u30fc\u30c9\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u3001Force Biphenyl\u30ab\u30e9\u30e0\u306f\u30d7\u30ec\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u4e0d\u8981\u3067\u5373\u5ea7\u306b\u5206\u6790\u3092\u958b\u59cb\u3067\u304d\u3001\u5168\u6e2c\u5b9a\u3092\u901a\u3058\u3066\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u85ac\u7269\u4e71\u7528\u691c\u67fb\uff08DOA\uff09\u3084\u65b0\u898f\u5411\u7cbe\u795e\u6027\u7269\u8cea\u3092\u542b\u3080\u5e45\u5e83\u3044\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u6c4e\u7528\u6027\u3092\u5099\u3048\u3066\u304a\u308a\u3001\u30ab\u30e9\u30e0\u4ea4\u63db\u306e\u983b\u5ea6\u3092\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/MATT-2026-EtG-EtS-\u65e5\u672c\u8a9e\u8a33\u30dd\u30b9\u30bf\u30fcv2.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of MATT 2026 EtG EtS \u65e5\u672c\u8a9e\u8a33\u30dd\u30b9\u30bf\u30fc.\"><\/object><a id=\"wp-block-file--media-2b1ed65f-7f16-465e-b007-f6360a3133c6\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/MATT-2026-EtG-EtS-\u65e5\u672c\u8a9e\u8a33\u30dd\u30b9\u30bf\u30fcv2.pdf\">MATT 2026 EtG EtS \u65e5\u672c\u8a9e\u8a33\u30dd\u30b9\u30bf\u30fc<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/MATT-2026-EtG-EtS-\u65e5\u672c\u8a9e\u8a33\u30dd\u30b9\u30bf\u30fcv2.pdf\" class=\"wp-block-file__button wp-element-button\" aria-describedby=\"wp-block-file--media-2b1ed65f-7f16-465e-b007-f6360a3133c6\" download>Download<\/a><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u8981\u7d04: \u30a8\u30c1\u30eb\u30b0\u30eb\u30af\u30ed\u30cb\u30c9\uff08EtG\uff09\u304a\u3088\u3073\u30a8\u30c1\u30eb\u30b5\u30eb\u30d5\u30a7\u30fc\u30c8\uff08EtS\uff09\u306f\u3001\u4f53\u5185\u3067\u306e\u30a2\u30eb\u30b3\u30fc\u30eb\u4ee3\u8b1d\u306b\u3088\u3063\u3066\u751f\u6210\u3055\u308c\u308b\u7269\u8cea\u3067\u3042\u308a\u3001\u98f2\u9152\u3092\u5ba2\u89b3\u7684\u306b\u793a\u3059\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3068\u3057\u3066\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306f\u6975\u6027\u304c\u9ad8\u3044\u305f\u3081\u3001\u9006\u76f8\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3088\u308b\u4fdd\u6301\u304c\u96e3\u3057\u304f\u3001\u5206\u6790\u4e0a\u306e\u8ab2\u984c\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u5c3f\u4e2d\u306b\u306f\u5206\u6790\u5bfe\u8c61\u3068\u540c\u4e00\u306e\u8cea\u91cf\u6570\uff08\u540c\u91cd\u4f53\uff09\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u304c\u5b58\u5728\u3059\u308b\u305f\u3081\u3001\u6b63\u78ba\u306a\u30c7\u30fc\u30bf\u3092\u5f97\u308b\u306b\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3088\u3063\u3066\u3053\u308c\u3089\u3092\u78ba\u5b9f\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002 \u672c\u7814\u7a76\u3067\u306f\u3001\u3053\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u3068\u5206\u6790\u5bfe\u8c61\u3068\u3092\u826f\u597d\u306b\u5206\u96e2\u3067\u304d\u308b\u9ad8\u901fLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u30ab\u30e9\u30e0\u306e\u30d7\u30ec\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u304a\u3053\u306a\u3046\u5fc5\u8981\u306a\u304f\u3001EtG\u304a\u3088\u3073EtS\u3092\u3068\u3082\u306b\u4fdd\u6301\u3057\u306a\u304c\u3089\u5c3f\u4e2d\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u3092\u5b89\u5b9a\u7684\u306b\u5206\u96e2\u3067\u304d\u308b\u3001\u5b9f\u7528\u7684\u306a\u30e1\u30bd\u30c3\u30c9\u3092\u78ba\u7acb\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u307e\u3057\u305f\u3002 \u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u306e\u8abf\u88fd\uff1aEtG\u304a\u3088\u3073EtS\u3092\u5408\u6210\u5c3f\u306b\u6dfb\u52a0\u3057\u300150\u301c1,000 ng\/mL\u306e\u6fc3\u5ea6\u7bc4\u56f2\u3067\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002QC\u30b5\u30f3\u30d7\u30eb\u306e\u8abf\u88fd\u3068\u524d\u51e6\u7406\uff1aQC\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u3001\u814e\u75be\u60a3\u304a\u3088\u3073\u809d\u75be\u60a3\u60a3\u8005\u30b5\u30f3\u30d7\u30eb\u3092\u542b\u30806\u30ed\u30c3\u30c8\u306e\u30d2\u30c8\u5c3f\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u30d2\u30c8\u5c3f\u306f0.1%\u30ae\u9178\u3092\u542b\u3080\u6c34\u306720\u500d\u5e0c\u91c8\u3057\u305f\u5f8c\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u304a\u3088\u3073\u9060\u5fc3\u5206\u96e2\u3092\u884c\u3044\u3001\u4e0a\u6e05\u3092Force Biphenyl\u30ab\u30e9\u30e0\uff08100 \u00d7 3 mm\u30013 \u00b5m\uff09\u306b\u6ce8\u5165\u3057\u307e\u3057\u305f\u3002\u5206\u6790\u6761\u4ef6\uff1a\u79fb\u52d5\u76f8\u306b\u306f0.1%\u30ae\u9178\u3092\u6dfb\u52a0\u3057\u305f\u6c34\u304a\u3088\u3073\u30e1\u30bf\u30ce\u30fc\u30eb\u3092\u4f7f\u7528\u3057\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3067\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u3092\u884c\u3044\u307e\u3057\u305f\u3002 \u958b\u767a\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u51686\u30ed\u30c3\u30c8\u306eQC\u5c3f\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3044\u3066\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u593e\u96d1\u7269\u3068\u5206\u6790\u5bfe\u8c61\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u3092\u9054\u6210\u3057\u3001\u6709\u610f\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5e72\u6e09\u306f\u8a8d\u3081\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u4e21\u5206\u6790\u5bfe\u8c61\u306b\u304a\u3044\u3066r\u00b2\u304c0.99\u4ee5\u4e0a\u306e\u826f\u597d\u306a\u76f4\u7dda\u6027\u304c\u78ba\u8a8d\u3055\u308c\u3001\u65e5\u5185\u304a\u3088\u3073\u65e5\u9593\u3068\u3082\u306b\u8a31\u5bb9\u7bc4\u56f2\u5185\u306e\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002 \u9577\u6642\u9593\u306e\u30d7\u30ec\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u5fc5\u8981\u3068\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u30de\u30eb\u30c1\u30e2\u30fc\u30c9\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u3001Force Biphenyl\u30ab\u30e9\u30e0\u306f\u30d7\u30ec\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u4e0d\u8981\u3067\u5373\u5ea7\u306b\u5206\u6790\u3092\u958b\u59cb\u3067\u304d\u3001\u5168\u6e2c\u5b9a\u3092\u901a\u3058\u3066\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u85ac\u7269\u4e71\u7528\u691c\u67fb\uff08DOA\uff09\u3084\u65b0\u898f\u5411\u7cbe\u795e\u6027\u7269\u8cea\u3092\u542b\u3080\u5e45\u5e83\u3044\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u6c4e\u7528\u6027\u3092\u5099\u3048\u3066\u304a\u308a\u3001\u30ab\u30e9\u30e0\u4ea4\u63db\u306e\u983b\u5ea6\u3092\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":51,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[810],"tags":[],"industries-application":[2277,2276,2266,2269],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[592,579],"class_list":["post-94281","post","type-post","status-publish","format-standard","hentry","category-posters-presentations-ja","industries-application-forensics-toxicology-ja","industries-application-forensics-ja","industries-application-clinical-ja","industries-application-clinical-toxicology-ja"],"acf":[],"taxonomy_info":{"category":[{"value":810,"label":"Posters &amp; Presentations"}],"industries-application":[{"value":2277,"label":"\u6cd5\u4e2d\u6bd2\u5b66"},{"value":2276,"label":"\u6cd5\u533b\u5b66"},{"value":2266,"label":"\u81e8\u5e8a"},{"value":2269,"label":"\u81e8\u5e8a\u6bd2\u6027\u5b66"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jared Burkhart","author_link":"https:\/\/discover.restek.com\/ja\/author\/jared-burkhart\/"},"comment_info":0,"category_info":[{"term_id":810,"name":"Posters &amp; Presentations","slug":"posters-presentations-ja","term_group":0,"term_taxonomy_id":810,"taxonomy":"category","description":"","parent":0,"count":125,"filter":"raw","cat_ID":810,"category_count":125,"category_description":"","cat_name":"Posters &amp; Presentations","category_nicename":"posters-presentations-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":592,"user_id":51,"is_guest":0,"slug":"jared-burkhart","display_name":"Jared Burkhart","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-burkhart-jared.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-burkhart-jared.jpg"},"author_category":"1","first_name":"Jared","last_name":"Burkhart","user_url":"https:\/\/www.linkedin.com\/in\/jaredburkhart\/","job_title":"Business Development Manager, Global Sales","description":"Jared Burkhart is the business development manager for life sciences at Restek with a BS in biology and an ASCP (C) certification. He brings 14 years of experience in LC\/MS laboratories supporting both clinical and forensic toxicology, giving him a strong understanding of the analytical and operational needs of these markets. An active member of MATT since 2023 and SOFT since 2025, Jared leverages his technical expertise and industry experience to help laboratories identify solutions that advance their testing capabilities."},{"term_id":579,"user_id":47,"is_guest":0,"slug":"jamie-l-york-phd","display_name":"Jamie L. York, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg"},"author_category":"1","first_name":"Jamie","last_name":"York","user_url":"https:\/\/www.linkedin.com\/in\/jamielyork\/","job_title":"Principal Scientist, LC Solutions","description":"Jamie York is a principal scientist in the Applications Lab at Restek Corporation. She leads the development of innovative analytical methods tailored to the food, clinical, environmental, and cannabis markets. Jamie earned her PhD in chemistry from The University of Texas at Arlington, where she gained extensive expertise in a range of analytical techniques, including gas chromatography\u2013vacuum ultraviolet (GC\u2013VUV); gas chromatography\u2013mass spectrometry (GC\u2013MS); matrix-assisted laser desorption\/ionization (MALDI); and liquid chromatography\u2013 mass spectrometry (LC\u2013MS\/MS); with a research emphasis on food and environmental analysis. Today, her work focuses on complex method development and advanced sample preparation strategies to support the evolving needs of the scientific community."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94281","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/51"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=94281"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94281\/revisions"}],"predecessor-version":[{"id":96163,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94281\/revisions\/96163"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=94281"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=94281"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=94281"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=94281"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=94281"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=94281"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=94281"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=94281"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=94281"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}