{"id":94317,"date":"2022-03-17T18:30:00","date_gmt":"2022-03-17T18:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=94317"},"modified":"2026-05-22T01:50:37","modified_gmt":"2026-05-22T01:50:37","slug":"3-ways-to-reduce-your-helium-usage","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3671-ja\/3-ways-to-reduce-your-helium-usage","title":{"rendered":"\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3059\u308b3\u3064\u306e\u65b9\u6cd5"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"3 Ways to Reduce Your Helium Usage\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/4FgEnFI5eNY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u6982\u8981&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d8\u30ea\u30a6\u30e0\u306e\u4f9b\u7d66\u4e0d\u8db3\u306f\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u91ce\u306b\u304a\u3044\u3066\u5f15\u304d\u7d9a\u304d\u5927\u304d\u306a\u8ab2\u984c\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u4fa1\u683c\u306f\u4e0a\u6607\u50be\u5411\u306b\u3042\u308a\u3001\u5165\u624b\u3082\u56f0\u96e3\u306b\u306a\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u554f\u984c\u306f\u4eca\u5f8c\u3082\u89e3\u6d88\u3055\u308c\u308b\u898b\u8fbc\u307f\u304c\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306eRestek Tip\u3067\u306f\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3057\u3066\u30ac\u30b9\u30dc\u30f3\u30d9\u3092\u6700\u5927\u9650\u306b\u6d3b\u7528\u3059\u308b\u305f\u3081\u306e3\u3064\u306e\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u95a2\u9023\u30ea\u30bd\u30fc\u30b9&nbsp;<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/ja\/pctj1729-ja\/?p=94318&amp;preview_id=94318&amp;preview_nonce=54890898b8&amp;preview=true\">GC\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u6c34\u7d20\u3078\u5207\u308a\u66ff\u3048\u308b\u30e1\u30ea\u30c3\u30c8\u3068\u5b89\u5168\u5bfe\u7b56\uff5c\u5206\u6790\u6642\u9593\u3092\u6700\u59272\u500d\u77ed\u7e2e\u3059\u308b\u5b9f\u8df5\u30ac\u30a4\u30c9<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/pcar2320-ja\/?p=94319&amp;preview_id=94319&amp;preview_nonce=fed8ea484d&amp;preview=true&amp;_thumbnail_id=7554\">\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u6c34\u7d20\u30fb\u7a92\u7d20\u3078\uff5cASTM D2887\u9ad8\u901fSimDist\u5206\u6790\u306b\u304a\u3051\u308b\u4ee3\u66ff\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6027\u80fd\u8a55\u4fa1\u3068\u5c0e\u5165\u624b\u9806<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u63a8\u5968\u88fd\u54c1&nbsp;<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/28500\" target=\"_blank\" rel=\"noopener\">Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1167\" target=\"_blank\" rel=\"noopener\">\u7a92\u7d20\u304a\u3088\u3073\u6c34\u7d20 \u30ac\u30b9\u767a\u751f\u88c5\u7f6e<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d8\u30ea\u30a6\u30e0\u306e\u4f9b\u7d66\u4e0d\u8db3\u306f\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u91ce\u306b\u304a\u3044\u3066\u5f15\u304d\u7d9a\u304d\u5927\u304d\u306a\u8ab2\u984c\u3067\u3059\u3002\u4fa1\u683c\u306f\u4e0a\u6607\u50be\u5411\u306b\u3042\u308a\u3001\u5165\u624b\u3082\u56f0\u96e3\u306b\u306a\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u554f\u984c\u306f\u4eca\u5f8c\u3082\u89e3\u6d88\u3055\u308c\u308b\u898b\u8fbc\u307f\u304c\u3042\u308a\u307e\u305b\u3093\u3002<br>\u3053\u306eRestek Tip\u3067\u306f\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3059\u308b\u305f\u3081\u306e3\u3064\u306e\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-1\" style=\"font-size:18px\"><strong>1\uff0e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30b9\u306e\u30ea\u30fc\u30af\u306b\u3064\u3044\u3066\u306f\u3001\u3053\u308c\u307e\u3067\u306e\u52d5\u753b\u3067\u3082\u7e70\u308a\u8fd4\u3057\u304a\u4f1d\u3048\u3057\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u305d\u308c\u3060\u3051\u91cd\u8981\u306a\u30c6\u30fc\u30de\u3060\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u30ea\u30fc\u30af\u304c\u767a\u751f\u3059\u308b\u3068\u6d41\u8def\u304c\u4e71\u308c\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u30ed\u30b9\u3084\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u306e\u4f4e\u4e0b\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u9006\u306b\u8a00\u3048\u3070\u3001\u30ea\u30fc\u30af\u3092\u306a\u304f\u3059\u3053\u3068\u3067\u5927\u91cf\u306e\u30d8\u30ea\u30a6\u30e0\u3092\u7bc0\u7d04\u3067\u304d\u307e\u3059\u3002<br>\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3046\u969b\u306f\u3001Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<br>\u30ac\u30b9\u306e\u4f9b\u7d66\u5143\uff08\u30ac\u30b9\u30dc\u30f3\u30d9\u30fb\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u30fc\uff09\u304b\u3089\u59cb\u3081\u3066\u3001\u88c5\u7f6e\u5185\u3092\u9806\u306b\u691c\u51fa\u5668\u307e\u3067\u78ba\u8a8d\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u7279\u306b\u30b7\u30fc\u30eb\u3084\u30d0\u30eb\u30d6\u306a\u3069\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u5b9f\u65bd\u3057\u305f\u7b87\u6240\u306f\u5ff5\u5165\u308a\u306b\u30c1\u30a7\u30c3\u30af\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br>\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306f\u5b9a\u671f\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u4e00\u74b0\u3068\u3057\u3066\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u65e9\u671f\u767a\u898b\u306b\u3088\u308a\u3001\u30d8\u30ea\u30a6\u30e0\u306e\u7121\u99c4\u306a\u6d88\u8cbb\u3092\u9632\u3050\u3068\u3068\u3082\u306b\u3001\u9ad8\u54c1\u8cea\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-2\" style=\"font-size:18px\"><strong>2. \u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306e\u6d3b\u7528<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u304a\u4f7f\u3044\u306eGC\u306b\u306f\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3059\u308b\u30e2\u30fc\u30c9\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u3054\u5b58\u77e5\u3067\u3057\u3087\u3046\u304b\u3002\u300c\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u300d\u307e\u305f\u306f\u300c\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u300d\u3068\u547c\u3070\u308c\u308b\u3053\u306e\u6a5f\u80fd\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<br>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u3001\u8a2d\u5b9a\u3057\u305f\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u306b\u5fdc\u3058\u305f\u5927\u91cf\u306e\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u304c\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u304b\u3089\u6392\u51fa\u3055\u308c\u307e\u3059\u3002\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u5f8c\u306e\u8a2d\u5b9a\u6642\u9593\u304c\u7d4c\u904e\u3057\u305f\u6642\u70b9\u3067\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u6d41\u91cf\u3092\u4e0b\u3052\u308b\u6a5f\u80fd\u3067\u3059\u3002<br>\u4ee5\u4e0b\u306b\u5177\u4f53\u7684\u306a\u4f8b\u3092\u793a\u3057\u307e\u3059\u3002<br>\u2022 \u30ab\u30e9\u30e0\u6d41\u91cf\uff1a2 mL\/min\u3001\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\uff1a3 mL\/min<br>\u2022 \u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\uff1a100:1\u3001\u30d8\u30ea\u30a6\u30e0\u7dcf\u6d41\u91cf\uff1a205 mL\/min<br>\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u306e1\u5206\u5f8c\u306b\u4f5c\u52d5\u3057\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6d41\u91cf\u3092\u8a2d\u5b9a\u5024\u306e20 mL\/min\u307e\u3067\u4e0b\u3052\u307e\u3059\u3002\u3053\u306e\u3068\u304d\u306e\u30ab\u30e9\u30e0\u6d41\u91cf\u3068\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u306f\u5909\u308f\u3089\u306a\u3044\u305f\u3081\u3001\u30d8\u30ea\u30a6\u30e0\u7dcf\u6d41\u91cf\u306f25 mL\/min\u3068\u306a\u308a\u307e\u3059\u3002\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306f\u6b21\u306e\u6ce8\u5165\u76f4\u524d\u306b\u30aa\u30d5\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u8a2d\u5b9a\u3067\u904b\u7528\u3059\u308b\u3068\u3001100\u56de\u306e\u5206\u6790\u5f53\u305f\u308a\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u6599\u309279%\u524a\u6e1b\u3067\u304d\u307e\u3059\u3002<br>\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306e\u4f7f\u7528\u65b9\u6cd5\u306b\u3064\u3044\u3066\u306f\u3001GC\u30e1\u30fc\u30ab\u30fc\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-3\" style=\"font-size:18px\"><strong>3. \u4f7f\u7528\u3057\u306a\u3044\u6642\u306fGC\u3092\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u3059\u308b<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u3092\u9577\u6642\u9593\u4f7f\u7528\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u52a0\u71b1\u30be\u30fc\u30f3\u3092\u51b7\u5374\u3057\u305f\u5f8c\u3001\u88c5\u7f6e\u3078\u306e\u30ac\u30b9\u4f9b\u7d66\u3092\u505c\u6b62\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u518d\u7a3c\u50cd\u6642\u306b\u306f\u3001\u9ad8\u6e29\u306b\u52a0\u71b1\u3059\u308b\u524d\u306b\u30ab\u30e9\u30e0\u3092\u30d1\u30fc\u30b8\u3059\u308b\u3053\u3068\u3092\u5fd8\u308c\u305a\u306b\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-4\" style=\"font-size:18px\"><strong>\u4ee3\u66ff\u30ad\u30e3\u30ea\u30a2\u30fc\u30ac\u30b9\u306b\u3064\u3044\u3066<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u306e\u76ee\u7684\u3084\u7528\u9014\u306b\u3088\u3063\u3066\u306f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u4ed6\u306e\u30ac\u30b9\u306b\u5207\u308a\u66ff\u3048\u308b\u3053\u3068\u3082\u9078\u629e\u80a2\u306e\u4e00\u3064\u3067\u3059\u3002\u6c34\u7d20\u304a\u3088\u3073\u7a92\u7d20\u306f\u5165\u624b\u3057\u3084\u3059\u304f\u3001\u30b3\u30b9\u30c8\u3082\u4f4e\u304f\u6291\u3048\u3089\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u5b9f\u9a13\u5ba4\u306b\u8a2d\u7f6e\u3057\u305f\u30ac\u30b9\u767a\u751f\u88c5\u7f6e\u3067\u305d\u306e\u5834\u3067\u88fd\u9020\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<br>\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u306e\u5207\u308a\u66ff\u3048\u304c\u5168\u3066\u306e\u30e9\u30dc\u306b\u9069\u3057\u305f\u89e3\u6c7a\u7b56\u3068\u306f\u8a00\u3048\u307e\u305b\u3093\u304c\u3001\u30b3\u30b9\u30c8\u524a\u6e1b\u3068\u5b89\u5b9a\u3057\u305f\u4f9b\u7d66\u3068\u3044\u3046\u89b3\u70b9\u304b\u3089\u3001\u4ee3\u66ff\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u5c0e\u5165\u3092\u691c\u8a0e\u3059\u308b\u4fa1\u5024\u306f\u5341\u5206\u306b\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u30d2\u30f3\u30c8\u3092\u53c2\u8003\u306b\u3001\u30d8\u30ea\u30a6\u30e0\u306e\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3057\u3001\u30ac\u30b9\u30dc\u30f3\u30d9\u3092\u3088\u308a\u6709\u52b9\u306b\u6d3b\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u5207\u308a\u66ff\u3048\u306b\u95a2\u3059\u308b\u3054\u8cea\u554f\u306f\u3001\u95a2\u9023\u30ea\u30bd\u30fc\u30b9\u3092\u3054\u78ba\u8a8d\u3044\u305f\u3060\u304f\u304b\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com<\/a>\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<br>Restek Tip\u3092\u3054\u8996\u8074\u3044\u305f\u3060\u304d\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6982\u8981&nbsp; \u30d8\u30ea\u30a6\u30e0\u306e\u4f9b\u7d66\u4e0d\u8db3\u306f\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u91ce\u306b\u304a\u3044\u3066\u5f15\u304d\u7d9a\u304d\u5927\u304d\u306a\u8ab2\u984c\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u4fa1\u683c\u306f\u4e0a\u6607\u50be\u5411\u306b\u3042\u308a\u3001\u5165\u624b\u3082\u56f0\u96e3\u306b\u306a\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u554f\u984c\u306f\u4eca\u5f8c\u3082\u89e3\u6d88\u3055\u308c\u308b\u898b\u8fbc\u307f\u304c\u3042\u308a\u307e\u305b\u3093\u3002 \u3053\u306eRestek Tip\u3067\u306f\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3057\u3066\u30ac\u30b9\u30dc\u30f3\u30d9\u3092\u6700\u5927\u9650\u306b\u6d3b\u7528\u3059\u308b\u305f\u3081\u306e3\u3064\u306e\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 \u95a2\u9023\u30ea\u30bd\u30fc\u30b9&nbsp; Restek\u63a8\u5968\u88fd\u54c1&nbsp; \u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8 \u30d8\u30ea\u30a6\u30e0\u306e\u4f9b\u7d66\u4e0d\u8db3\u306f\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u91ce\u306b\u304a\u3044\u3066\u5f15\u304d\u7d9a\u304d\u5927\u304d\u306a\u8ab2\u984c\u3067\u3059\u3002\u4fa1\u683c\u306f\u4e0a\u6607\u50be\u5411\u306b\u3042\u308a\u3001\u5165\u624b\u3082\u56f0\u96e3\u306b\u306a\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u554f\u984c\u306f\u4eca\u5f8c\u3082\u89e3\u6d88\u3055\u308c\u308b\u898b\u8fbc\u307f\u304c\u3042\u308a\u307e\u305b\u3093\u3002\u3053\u306eRestek Tip\u3067\u306f\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3059\u308b\u305f\u3081\u306e3\u3064\u306e\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 1\uff0e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af \u30ac\u30b9\u306e\u30ea\u30fc\u30af\u306b\u3064\u3044\u3066\u306f\u3001\u3053\u308c\u307e\u3067\u306e\u52d5\u753b\u3067\u3082\u7e70\u308a\u8fd4\u3057\u304a\u4f1d\u3048\u3057\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u305d\u308c\u3060\u3051\u91cd\u8981\u306a\u30c6\u30fc\u30de\u3060\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u30ea\u30fc\u30af\u304c\u767a\u751f\u3059\u308b\u3068\u6d41\u8def\u304c\u4e71\u308c\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u30ed\u30b9\u3084\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u306e\u4f4e\u4e0b\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u9006\u306b\u8a00\u3048\u3070\u3001\u30ea\u30fc\u30af\u3092\u306a\u304f\u3059\u3053\u3068\u3067\u5927\u91cf\u306e\u30d8\u30ea\u30a6\u30e0\u3092\u7bc0\u7d04\u3067\u304d\u307e\u3059\u3002\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3046\u969b\u306f\u3001Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u30ac\u30b9\u306e\u4f9b\u7d66\u5143\uff08\u30ac\u30b9\u30dc\u30f3\u30d9\u30fb\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u30fc\uff09\u304b\u3089\u59cb\u3081\u3066\u3001\u88c5\u7f6e\u5185\u3092\u9806\u306b\u691c\u51fa\u5668\u307e\u3067\u78ba\u8a8d\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u7279\u306b\u30b7\u30fc\u30eb\u3084\u30d0\u30eb\u30d6\u306a\u3069\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u5b9f\u65bd\u3057\u305f\u7b87\u6240\u306f\u5ff5\u5165\u308a\u306b\u30c1\u30a7\u30c3\u30af\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306f\u5b9a\u671f\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u4e00\u74b0\u3068\u3057\u3066\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u65e9\u671f\u767a\u898b\u306b\u3088\u308a\u3001\u30d8\u30ea\u30a6\u30e0\u306e\u7121\u99c4\u306a\u6d88\u8cbb\u3092\u9632\u3050\u3068\u3068\u3082\u306b\u3001\u9ad8\u54c1\u8cea\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 2. \u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306e\u6d3b\u7528 \u304a\u4f7f\u3044\u306eGC\u306b\u306f\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3059\u308b\u30e2\u30fc\u30c9\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u3054\u5b58\u77e5\u3067\u3057\u3087\u3046\u304b\u3002\u300c\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u300d\u307e\u305f\u306f\u300c\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u300d\u3068\u547c\u3070\u308c\u308b\u3053\u306e\u6a5f\u80fd\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u3001\u8a2d\u5b9a\u3057\u305f\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u306b\u5fdc\u3058\u305f\u5927\u91cf\u306e\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u304c\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u304b\u3089\u6392\u51fa\u3055\u308c\u307e\u3059\u3002\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u5f8c\u306e\u8a2d\u5b9a\u6642\u9593\u304c\u7d4c\u904e\u3057\u305f\u6642\u70b9\u3067\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u6d41\u91cf\u3092\u4e0b\u3052\u308b\u6a5f\u80fd\u3067\u3059\u3002\u4ee5\u4e0b\u306b\u5177\u4f53\u7684\u306a\u4f8b\u3092\u793a\u3057\u307e\u3059\u3002\u2022 \u30ab\u30e9\u30e0\u6d41\u91cf\uff1a2 mL\/min\u3001\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\uff1a3 mL\/min\u2022 \u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\uff1a100:1\u3001\u30d8\u30ea\u30a6\u30e0\u7dcf\u6d41\u91cf\uff1a205 mL\/min\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u306e1\u5206\u5f8c\u306b\u4f5c\u52d5\u3057\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6d41\u91cf\u3092\u8a2d\u5b9a\u5024\u306e20 mL\/min\u307e\u3067\u4e0b\u3052\u307e\u3059\u3002\u3053\u306e\u3068\u304d\u306e\u30ab\u30e9\u30e0\u6d41\u91cf\u3068\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u306f\u5909\u308f\u3089\u306a\u3044\u305f\u3081\u3001\u30d8\u30ea\u30a6\u30e0\u7dcf\u6d41\u91cf\u306f25 mL\/min\u3068\u306a\u308a\u307e\u3059\u3002\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306f\u6b21\u306e\u6ce8\u5165\u76f4\u524d\u306b\u30aa\u30d5\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u8a2d\u5b9a\u3067\u904b\u7528\u3059\u308b\u3068\u3001100\u56de\u306e\u5206\u6790\u5f53\u305f\u308a\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u6599\u309279%\u524a\u6e1b\u3067\u304d\u307e\u3059\u3002\u30ac\u30b9\u30bb\u30fc\u30d0\u30fc\u30e2\u30fc\u30c9\u306e\u4f7f\u7528\u65b9\u6cd5\u306b\u3064\u3044\u3066\u306f\u3001GC\u30e1\u30fc\u30ab\u30fc\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002 3. \u4f7f\u7528\u3057\u306a\u3044\u6642\u306fGC\u3092\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u3059\u308b GC\u3092\u9577\u6642\u9593\u4f7f\u7528\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u52a0\u71b1\u30be\u30fc\u30f3\u3092\u51b7\u5374\u3057\u305f\u5f8c\u3001\u88c5\u7f6e\u3078\u306e\u30ac\u30b9\u4f9b\u7d66\u3092\u505c\u6b62\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u518d\u7a3c\u50cd\u6642\u306b\u306f\u3001\u9ad8\u6e29\u306b\u52a0\u71b1\u3059\u308b\u524d\u306b\u30ab\u30e9\u30e0\u3092\u30d1\u30fc\u30b8\u3059\u308b\u3053\u3068\u3092\u5fd8\u308c\u305a\u306b\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002 \u4ee3\u66ff\u30ad\u30e3\u30ea\u30a2\u30fc\u30ac\u30b9\u306b\u3064\u3044\u3066 \u5206\u6790\u306e\u76ee\u7684\u3084\u7528\u9014\u306b\u3088\u3063\u3066\u306f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u4ed6\u306e\u30ac\u30b9\u306b\u5207\u308a\u66ff\u3048\u308b\u3053\u3068\u3082\u9078\u629e\u80a2\u306e\u4e00\u3064\u3067\u3059\u3002\u6c34\u7d20\u304a\u3088\u3073\u7a92\u7d20\u306f\u5165\u624b\u3057\u3084\u3059\u304f\u3001\u30b3\u30b9\u30c8\u3082\u4f4e\u304f\u6291\u3048\u3089\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u5b9f\u9a13\u5ba4\u306b\u8a2d\u7f6e\u3057\u305f\u30ac\u30b9\u767a\u751f\u88c5\u7f6e\u3067\u305d\u306e\u5834\u3067\u88fd\u9020\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u306e\u5207\u308a\u66ff\u3048\u304c\u5168\u3066\u306e\u30e9\u30dc\u306b\u9069\u3057\u305f\u89e3\u6c7a\u7b56\u3068\u306f\u8a00\u3048\u307e\u305b\u3093\u304c\u3001\u30b3\u30b9\u30c8\u524a\u6e1b\u3068\u5b89\u5b9a\u3057\u305f\u4f9b\u7d66\u3068\u3044\u3046\u89b3\u70b9\u304b\u3089\u3001\u4ee3\u66ff\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u5c0e\u5165\u3092\u691c\u8a0e\u3059\u308b\u4fa1\u5024\u306f\u5341\u5206\u306b\u3042\u308a\u307e\u3059\u3002 \u3053\u308c\u3089\u306e\u30d2\u30f3\u30c8\u3092\u53c2\u8003\u306b\u3001\u30d8\u30ea\u30a6\u30e0\u306e\u4f7f\u7528\u91cf\u3092\u524a\u6e1b\u3057\u3001\u30ac\u30b9\u30dc\u30f3\u30d9\u3092\u3088\u308a\u6709\u52b9\u306b\u6d3b\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u5207\u308a\u66ff\u3048\u306b\u95a2\u3059\u308b\u3054\u8cea\u554f\u306f\u3001\u95a2\u9023\u30ea\u30bd\u30fc\u30b9\u3092\u3054\u78ba\u8a8d\u3044\u305f\u3060\u304f\u304b\u3001www.restek.com\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002Restek Tip\u3092\u3054\u8996\u8074\u3044\u305f\u3060\u304d\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2570,2552],"resource-technique":[2340],"ppma_author":[2814],"class_list":["post-94317","post","type-post","status-publish","format-standard","hentry","category-videos-ja","product-library-gas-purification-generators-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"product-library":[{"value":2570,"label":"GC \u30ac\u30b9\u7cbe\u88fd\uff5c\u767a\u751f\u88c5\u7f6e"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94317","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=94317"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94317\/revisions"}],"predecessor-version":[{"id":95508,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94317\/revisions\/95508"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=94317"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=94317"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=94317"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=94317"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=94317"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=94317"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=94317"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=94317"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=94317"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}