{"id":94318,"date":"2020-10-26T14:30:00","date_gmt":"2020-10-26T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=94318"},"modified":"2026-06-04T02:18:36","modified_gmt":"2026-06-04T02:18:36","slug":"benefits-and-considerations-of-converting-to-hydrogen-carrier-gas","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/pctj1729-ja\/benefits-and-considerations-of-converting-to-hydrogen-carrier-gas","title":{"rendered":"GC\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u6c34\u7d20\u3078\u5207\u308a\u66ff\u3048\u308b\u30e1\u30ea\u30c3\u30c8\u3068\u5b89\u5168\u5bfe\u7b56\uff5c\u5206\u6790\u6642\u9593\u3092\u6700\u59272\u500d\u77ed\u7e2e\u3059\u308b\u5b9f\u8df5\u30ac\u30a4\u30c9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u203b\u672c\u8a18\u4e8b\u306f&nbsp;<em>Petro Industry News<\/em> \u306b\u63b2\u8f09\u3055\u308c\u305f\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u8ee2\u8f09\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u30e9\u30dc\u306e\u591a\u304f\u304c\u30d8\u30ea\u30a6\u30e0\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3057\u3066\u3044\u308b\u306e\u306f\u3001\u7a92\u7d20\u3088\u308a\u9ad8\u3044\u7dda\u901f\u5ea6\u3067\u3082\u826f\u597d\u306a\u5206\u96e2\u52b9\u7387\u304c\u5f97\u3089\u308c\u3001\u6c34\u7d20\u3068\u6bd4\u3079\u3066\u5b89\u5168\u306b\u6271\u3048\u308b\u305f\u3081\u3067\u3059\u3002\u3057\u304b\u3057\u30d8\u30ea\u30a6\u30e0\u306f\u5e0c\u5c11\u306a\u5929\u7136\u8cc7\u6e90\u3067\u3042\u308a\u3001\u5165\u624b\u304c\u307e\u3059\u307e\u3059\u56f0\u96e3\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u306e\u4f9b\u7d66\u4e0d\u8db3\u306b\u3088\u308a\u4fa1\u683c\u306f\u5927\u5e45\u306b\u4e0a\u6607\u3057\u3001\u5fc5\u8981\u306a\u3068\u304d\u306b\u5165\u624b\u3067\u304d\u306a\u3044\u30b1\u30fc\u30b9\u3082\u751f\u3058\u3066\u3044\u307e\u3059\u3002\u30d8\u30ea\u30a6\u30e0\u306f\u5b87\u5b99\u306b\u306f\u8c4a\u5bcc\u306b\u5b58\u5728\u3057\u307e\u3059\u304c\u3001\u5730\u7403\u4e0a\u3067\u306f\u5929\u7136\u30ac\u30b9\u306e\u5206\u7559\u306b\u3088\u3063\u3066\u88fd\u9020\u3055\u308c\u308b\u305f\u3081\u975e\u5e38\u306b\u5e0c\u5c11\u3067\u3059\u3002\u30a2\u30e1\u30ea\u30ab\u306f\u4e3b\u8981\u306a\u751f\u7523\u56fd\u3067\u3059\u304c\u3001\u305d\u306e\u4e3b\u8981\u5099\u84c4\u3067\u3042\u308b\u7c73\u56fd\u56fd\u5bb6\u30d8\u30ea\u30a6\u30e0\u5099\u84c4\uff08\u4e16\u754c\u4f9b\u7d66\u91cf\u306e\u7d0430%\u3092\u5360\u3081\u308b\uff09\u306f2018\u5e74\u307e\u3067\u306b\u67af\u6e07\u3059\u308b\u3068\u4e88\u6e2c\u3055\u308c\u3066\u3044\u307e\u3057\u305f [1]\u3002\u4ed6\u306e\u4f9b\u7d66\u6e90\u306b\u3088\u308b\u4e0d\u8db3\u89e3\u6d88\u3082\u898b\u8fbc\u3081\u306a\u3044\u3053\u3068\u304b\u3089\u3001\u591a\u304f\u306eGC\u30e9\u30dc\u304c\u4ee3\u66ff\u624b\u6bb5\u3068\u3057\u3066\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u5207\u308a\u66ff\u3048\u3092\u691c\u8a0e\u3057\u3066\u3044\u307e\u3059\u3002\u6c34\u7d20\u306f\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u3001\u4f4e\u30b3\u30b9\u30c8\u3001\u5b89\u5b9a\u3057\u305f\u4f9b\u7d66\u3068\u3044\u3046\u70b9\u3067\u512a\u308c\u305f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u9078\u629e\u80a2\u3067\u3059\u304c\u3001\u53ef\u71c3\u6027\u304c\u3042\u308b\u305f\u3081\u5c0e\u5165\u306b\u306f\u5b89\u5168\u9762\u3078\u306e\u5341\u5206\u306a\u914d\u616e\u304c\u5fc5\u8981\u3067\u3059\u3002\u5b89\u5168\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u3092\u6d3b\u7528\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306e\u624b\u9806\u3092\u6b63\u3057\u304f\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001\u751f\u7523\u6027\u5411\u4e0a\u3068\u30b3\u30b9\u30c8\u524a\u6e1b\u306e\u6069\u6075\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b89\u5168\u6027\u306b\u95a2\u3059\u308b\u6ce8\u610f\u70b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u5207\u308a\u66ff\u3048\u3067\u6700\u521d\u306b\u8003\u616e\u3059\u3079\u304d\u306f\u3001\u5b89\u5168\u4e0a\u306e\u30ea\u30b9\u30af\u3092\u6b63\u3057\u304f\u7406\u89e3\u3057\u3001\u9069\u5207\u306b\u7ba1\u7406\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u9069\u5207\u306a\u6a5f\u5668\u3068\u904b\u7528\u65b9\u6cd5\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3001\u30ea\u30b9\u30af\u3092\u5927\u5e45\u306b\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-1\" style=\"font-size:18px\">\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u306b\u3088\u308b\u8caf\u8535\u30ea\u30b9\u30af\u306e\u6700\u5c0f\u5316<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u9ad8\u5727\u30ac\u30b9\u30dc\u30f3\u30d9\u304c\u901a\u5e3850 L\u30fb200\u6c17\u5727\u306e\u6c34\u7d20\u3092\u8caf\u8535\u3059\u308b\u306e\u306b\u5bfe\u3057\u3001\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u306e\u8caf\u8535\u91cf\u306f\u6700\u592760 mL\u30fb7\u6c17\u5727\u4ee5\u4e0b\u306b\u3068\u3069\u307e\u308a\u307e\u3059\u3002\u30aa\u30f3\u30c7\u30de\u30f3\u30c9\u3067\u7d99\u7d9a\u7684\u306b\u6c34\u7d20\u3092\u4f9b\u7d66\u3067\u304d\u308b\u4e00\u65b9\u3001\u8caf\u8535\u91cf\u304c\u975e\u5e38\u306b\u5c11\u306a\u3044\u305f\u3081\u3001\u5b89\u5168\u6027\u304c\u5927\u5e45\u306b\u5411\u4e0a\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u304b\u3089\u306e\u6d41\u91cf\u306f\u5236\u5fa1\u3055\u308c\u3066\u304a\u308a\u3001\u4e00\u822c\u7684\u306a\u6a5f\u7a2e\u3067\u306e\u6700\u5927\u6d41\u91cf\u306f\u7d04500 mL\/min\u3067\u3059\u3002\u3053\u308c\u306f\u3001\u4e00\u822c\u7684\u306aGC\u30aa\u30fc\u30d6\u30f3\u5185\u3067\u6c34\u7d20\u306e\u7206\u767a\u4e0b\u9650\u754c\uff08LEL\uff09\u306b\u9054\u3059\u308b\u306e\u306b\u5fc5\u8981\u306a\u6d41\u91cf\uff082 L\/min\uff09\u3092\u5927\u5e45\u306b\u4e0b\u56de\u308b\u5024\u3067\u3059\u3002\u30ea\u30fc\u30af\u30bb\u30f3\u30b5\u30fc\u3068\u81ea\u52d5\u30b7\u30e3\u30c3\u30c8\u30aa\u30d5\u6a5f\u80fd\u3082\u5185\u8535\u3055\u308c\u3066\u304a\u308a\u3001\u7570\u5e38\u3092\u691c\u77e5\u3059\u308b\u3068\u5373\u5ea7\u306b\u505c\u6b62\u3057\u307e\u3059\u3002\u30d8\u30ea\u30a6\u30e0\u30b3\u30b9\u30c8\u306e\u6025\u9a30\u304c\u7d9a\u304f\u4e2d\u3001\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u306f\u6295\u8cc7\u56de\u53ce\u3082\u65e9\u304f\u3001\u9ad8\u5727\u30ac\u30b9\u30dc\u30f3\u30d9\u306b\u4f34\u3046\u5b89\u5168\u30ea\u30b9\u30af\u3092\u6839\u672c\u304b\u3089\u6392\u9664\u3057\u306a\u304c\u3089\u5b89\u5b9a\u3057\u305f\u30ac\u30b9\u4f9b\u7d66\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-2\" style=\"font-size:18px\">\u30d5\u30ed\u30fc\u5236\u5fa1\u5206\u6790\u306b\u3088\u308b\u30ea\u30fc\u30af\u6642\u306e\u30ea\u30b9\u30af\u4f4e\u6e1b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u306e\u6d41\u91cf\u5236\u5fa1\u306b\u306f\u5b9a\u5727\u30e2\u30fc\u30c9\u3068\u5b9a\u6d41\u91cf\u30e2\u30fc\u30c9\u304c\u9078\u629e\u3067\u304d\u307e\u3059\u304c\u3001\u6c34\u7d20\u4f7f\u7528\u6642\u306f\u5b9a\u6d41\u91cf\u30e2\u30fc\u30c9\u3067\u306e\u904b\u8ee2\u304c\u6700\u5584\u306e\u9078\u629e\u80a2\u3067\u3059\u3002\u4e07\u304c\u4e00\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u304c\u6ce8\u5165\u53e3\u4ed8\u8fd1\u3067\u6298\u308c\u305f\u5834\u5408\u3001\u96fb\u5b50\u5727\u529b\u5236\u5fa1\uff08EPC\uff09\u3092\u6301\u3064GC\u306f\u30b7\u30b9\u30c6\u30e0\u5185\u306e\u5727\u529b\u7570\u5e38\u3092\u5373\u5ea7\u306b\u691c\u77e5\u3057\u3001\u81ea\u52d5\u7684\u306b\u30b9\u30bf\u30f3\u30d0\u30a4\u30e2\u30fc\u30c9\u306b\u79fb\u884c\u3057\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u306b\u653e\u51fa\u3055\u308c\u308b\u6c34\u7d20\u306f\u30a4\u30f3\u30ec\u30c3\u30c8\u304a\u3088\u3073\u30ab\u30e9\u30e0\u5185\u90e8\u306e\u4f53\u7a4d\u5206\u306e\u307f\u306b\u9650\u3089\u308c\u308b\u305f\u3081\u3001\u5371\u967a\u306a\u6fc3\u5ea6\u3078\u306e\u5230\u9054\u30ea\u30b9\u30af\u306f\u6975\u3081\u3066\u4f4e\u304f\u6291\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-3\" style=\"font-size:18px\">\u7570\u7a2e\u30ac\u30b9\u691c\u77e5\u30b7\u30b9\u30c6\u30e0\u306b\u3088\u308b\u591a\u5c64\u9632\u5fa1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3088\u308a\u9ad8\u3044\u5b89\u5168\u6027\u304c\u6c42\u3081\u3089\u308c\u308b\u74b0\u5883\u3067\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u5185\u306e\u7a7a\u6c17\u3092\u5e38\u6642\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3057\u3066\u7570\u7a2e\u30ac\u30b9\uff08\u30d8\u30ea\u30a6\u30e0\u3084\u6c34\u7d20\u306a\u3069\uff09\u306e\u5b58\u5728\u3092\u691c\u77e5\u3059\u308b\u30b7\u30b9\u30c6\u30e0\u306e\u5c0e\u5165\u3082\u6709\u52b9\u3067\u3059\u3002\u30ac\u30b9\u767a\u751f\u88c5\u7f6e\u30fb\u30d5\u30ed\u30fc\u5236\u5fa1\u30fb\u30ac\u30b9\u691c\u77e5\u30b7\u30b9\u30c6\u30e0\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u591a\u5c64\u7684\u306a\u5b89\u5168\u5bfe\u7b56\u304c\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-4\" style=\"font-size:18px\">MXT\u30e1\u30bf\u30eb\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u3088\u308b\u7269\u7406\u7684\u30ea\u30b9\u30af\u306e\u6392\u9664<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ab\u30e9\u30e0\u306e\u7834\u640d\u30ea\u30b9\u30af\u3092\u30bc\u30ed\u306b\u3059\u308b\u306b\u306f\u3001Restek\u306eMXT\u30e1\u30bf\u30eb\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u304c\u6700\u3082\u78ba\u5b9f\u306a\u89e3\u6c7a\u7b56\u3067\u3059\u3002\u7269\u7406\u7684\u306b\u6298\u308c\u306a\u3044\u5805\u7262\u306a\u69cb\u9020\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u7834\u640d\u306b\u8d77\u56e0\u3059\u308b\u6c34\u7d20\u6f0f\u6d29\u306e\u30ea\u30b9\u30af\u3092\u6839\u672c\u304b\u3089\u6392\u9664\u3067\u304d\u307e\u3059\u3002MXT\u30ab\u30e9\u30e0\u306f\u6700\u9ad8450 \u00b0C\u307e\u3067\u306e\u9ad8\u6e29\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\uff08\u6a21\u64ec\u84b8\u7559\u30fb\u30d0\u30a4\u30aa\u30c7\u30a3\u30fc\u30bc\u30eb\u5206\u6790\u306a\u3069\uff09\u3067\u9577\u5e74\u306e\u5b9f\u7e3e\u3092\u6301\u3064\u4e00\u65b9\u3001\u4f4e\u6e29\u5206\u6790\u3067\u3082\u512a\u308c\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u7279\u306bSiltek\u51e6\u7406\u3092\u65bd\u3057\u305f\u9ad8\u4e0d\u6d3b\u6027\u5316\u30b0\u30ec\u30fc\u30c9\u306f\u3001\u6d3b\u6027\u5316\u306b\u3088\u308b\u5206\u6790\u3078\u306e\u60aa\u5f71\u97ff\u3092\u6392\u9664\u3057\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u826f\u597d\u306a\u5206\u6790\u7d50\u679c\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002 <\/p>\n<\/div>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e1\u30ea\u30c3\u30c8\u3068\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-5\" style=\"font-size:18px\">\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u306b\u304a\u3051\u308b\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u512a\u4f4d\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u7d20\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u6700\u5927\u306e\u30e1\u30ea\u30c3\u30c8\u306f\u3001\u5206\u6790\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3067\u304d\u308b\u3053\u3068\u3067\u3059\u3002\u5206\u96e2\u5ea6\u306b\u308f\u305a\u304b\u306a\u4f4e\u4e0b\u304c\u751f\u3058\u308b\u5834\u5408\u304c\u3042\u308b\u3082\u306e\u306e\u3001\u73fe\u5b9f\u7684\u306b\u5206\u6790\u6642\u9593\u30921.5\u301c2\u500d\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3068\u751f\u7523\u6027\u3092\u5927\u304d\u304f\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-6\" style=\"font-size:18px\">\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7a2e\u985e\u3068\u52b9\u7387\u30fb\u7dda\u901f\u5ea6\u306e\u95a2\u4fc2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306a\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306evan Deemter\u30d7\u30ed\u30c3\u30c8\u3092\u78ba\u8a8d\u3059\u308b\u3068\u3001\u3053\u306e\u70b9\u306f\u660e\u3089\u304b\u3067\u3059\uff08<strong>Figure 1<\/strong>\uff09\u3002<strong>\u7a92\u7d20<\/strong>\u306f\u6700\u3082\u9ad8\u3044\u52b9\u7387\uff08\u6700\u77ed\u306e\u7406\u8ad6\u6bb5\u76f8\u5f53\u9ad8\u3055\uff09\u3092\u793a\u3057\u307e\u3059\u304c\u3001\u6700\u5927\u52b9\u7387\u304c\u5f97\u3089\u308c\u308b\u306e\u306f\u7d0410 cm\/sec\u3068\u3044\u3046\u975e\u5e38\u306b\u4f4e\u3044\u7dda\u901f\u5ea6\u306b\u9650\u3089\u308c\u3001\u7dda\u901f\u5ea6\u3092\u4e0a\u3052\u308b\u3068\u52b9\u7387\u306f\u6025\u6fc0\u306b\u4f4e\u4e0b\u3057\u307e\u3059\u3002<strong>\u30d8\u30ea\u30a6\u30e0<\/strong>\u306f\u52b9\u7387\u304c\u3084\u3084\u52a3\u308b\u3082\u306e\u306e\u3001\u3088\u308a\u5b9f\u7528\u7684\u306a\u7dda\u901f\u5ea6\u57df\u3067\u4f7f\u7528\u3067\u304d\uff08\u6700\u9069\u306f\u7d0425 cm\/sec\u3001\u9ad8\u7dda\u901f\u5ea6\u3067\u306e\u52b9\u7387\u4f4e\u4e0b\u3082\u7de9\u3084\u304b\uff09\u3001\u6271\u3044\u3084\u3059\u3044\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3067\u3059\u3002\u3057\u304b\u3057\u6700\u3082\u512a\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3092\u793a\u3059\u306e\u306f<strong>\u6c34\u7d20<\/strong>\u3067\u3059\u3002\u6700\u5927\u52b9\u7387\u306f\u30d8\u30ea\u30a6\u30e0\u3068\u540c\u7b49\u3067\u3042\u308a\u306a\u304c\u3089\u3001\u306f\u308b\u304b\u306b\u5e83\u3044\u7dda\u901f\u5ea6\u57df\u3067\u826f\u597d\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u6c34\u7d20\u4f7f\u7528\u6642\u306e\u6700\u9069\u7dda\u901f\u5ea6\u306f\u7d0440\u301c45 cm\/sec\u3067\u3042\u308a\u3001\u30d8\u30ea\u30a6\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u5206\u6790\u6642\u9593\u304c\u5927\u5e45\u306b\u77ed\u7e2e\u3055\u308c\u3001\u591a\u304f\u306e\u5834\u5408\u3067\u534a\u5206\u306e\u6642\u9593\u3067\u306e\u6e2c\u5b9a\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0\u6c34\u7d20\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u6642\u306e\u534a\u5206\u306e\u6642\u9593\u3067\u52b9\u7387\u3088\u304f\u5206\u96e2\u53ef\u80fd<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image94318_408f25-7d .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image94318_408f25-7d\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"628\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-PCTJ1729-01-1024x628.jpg\" alt=\"\" class=\"kb-img wp-image-23752\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCTJ1729-01-1024x628.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCTJ1729-01-300x184.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCTJ1729-01-768x471.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCTJ1729-01-1536x942.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCTJ1729-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-7\" style=\"font-size:18px\">\u70ad\u5316\u6c34\u7d20\u6df7\u5408\u7269\u306e\u5206\u6790\u4e8b\u4f8b\u306b\u3088\u308b\u5b9f\u8a3c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u7406\u8ad6\u7684\u306a\u30e1\u30ea\u30c3\u30c8\u3092\u5b9f\u969b\u306e\u30c7\u30fc\u30bf\u3067\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002<strong>Figure 2<\/strong>\u306f\u3001\u540c\u4e00\u306eGC\u30b7\u30b9\u30c6\u30e0\u3092\u4f7f\u7528\u3057\u3066\u30d8\u30ea\u30a6\u30e0\u3068\u6c34\u7d20\u3067\u305d\u308c\u305e\u308c\u70ad\u5316\u6c34\u7d20\u6df7\u5408\u7269\u3092\u5206\u6790\u3057\u3001\u7d50\u679c\u3092\u6bd4\u8f03\u3057\u305f\u3082\u306e\u3067\u3059\u3002<br>\u6c34\u7d20\u4f7f\u7528\u6642\u306f\u30d8\u30ea\u30a6\u30e0\u306e2\u500d\u306e\u7dda\u901f\u5ea6\uff0846 cm\/sec\uff09\u3067\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u5168\u6210\u5206\u304c\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u6642\u306e\u534a\u5206\u306e\u6642\u9593\u3067\u6eb6\u51fa\u3057\u307e\u3057\u305f\u3002\u6ce8\u76ee\u3059\u3079\u304d\u70b9\u3068\u3057\u3066\u3001\u7dda\u901f\u5ea6\u30922\u500d\u306b\u3057\u3066\u3082\u5404\u6210\u5206\u9593\u306e\u5206\u96e2\u306f\u826f\u597d\u306b\u7dad\u6301\u3055\u308c\u3066\u304a\u308a\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u52b9\u7387\u3078\u306e\u60aa\u5f71\u97ff\u306f\u307b\u3068\u3093\u3069\u8a8d\u3081\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002<br>\u3055\u3089\u306b\u3001\u5206\u6790\u6642\u9593\u304c\u534a\u5206\u306b\u306a\u308b\u3068\u30d4\u30fc\u30af\u5e45\u3082\u534a\u5206\u306b\u306a\u308b\u305f\u3081\u3001\u30d4\u30fc\u30af\u9ad8\u3055\u306f2\u500d\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u611f\u5ea6\u304c\u5411\u4e0a\u3057\u3001\u3088\u308a\u5c11\u306a\u3044\u6ce8\u5165\u91cf\u3067\u3082\u540c\u7b49\u306e\u691c\u51fa\u611f\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u6ce8\u5165\u91cf\u306e\u524a\u6e1b\u306f\u30ab\u30e9\u30e0\u3084\u6ce8\u5165\u53e3\u306e\u6c5a\u67d3\u4f4e\u6e1b\u306b\u3082\u3064\u306a\u304c\u308a\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30b3\u30b9\u30c8\u306e\u524a\u6e1b\u3068\u3044\u3046\u4ed8\u52a0\u7684\u306a\u30e1\u30ea\u30c3\u30c8\u3082\u751f\u307e\u308c\u307e\u3059\u3002<br><strong>\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u30e1\u30ea\u30c3\u30c8<\/strong>\u306f\u5206\u6790\u901f\u5ea6\u306e\u5411\u4e0a\u306b\u3068\u3069\u307e\u3089\u305a\u3001\u611f\u5ea6\u30fb\u30b3\u30b9\u30c8\u30fb\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u89b3\u70b9\u3067\u3082\u591a\u304f\u306e\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u3053\u308c\u3089\u306e\u30e1\u30ea\u30c3\u30c8\u3092\u6700\u5927\u9650\u306b\u6d3b\u304b\u3059\u305f\u3081\u306b\u306f\u3001\u5b9f\u88c5\u524d\u306b\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u3092\u9069\u5207\u306b\u884c\u3046\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0\u6c34\u7d20\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u70ad\u5316\u6c34\u7d20\u3092\u534a\u5206\u306e\u6642\u9593\u3067\u5206\u96e2\u3067\u304d\u3001\u751f\u7523\u6027\u304c\u5927\u5e45\u306b\u5411\u4e0a<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1171.png\" alt=\"Comparison of Helium and Hydrogen Carrier Gases\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1171<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rt-Alumina BOND\/MAPD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Hydrocarbon mixture<\/td><\/tr>\n<tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td>split<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Using hydrogen as the carrier gas allows the linear velocity to be doubled so compounds elute in half the time.<br \/>Helium: 23 cm\/sec<br \/>Hydrogen: 46 cm\/sec<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1171.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-8\" style=\"font-size:18px\">\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u30e1\u30bd\u30c3\u30c9\u5909\u63db<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u3067\u306f\u3001\u6eb6\u51fa\u6e29\u5ea6\u3078\u306e\u5f71\u97ff\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<strong>\u7b49\u6e29\u5206\u6790\u30e1\u30bd\u30c3\u30c9<\/strong>\u306e\u5834\u5408\u3001\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u6c34\u7d20\u3078\u306e\u5909\u63db\u306f\u6bd4\u8f03\u7684\u30b7\u30f3\u30d7\u30eb\u3067\u3059\u3002\u7dda\u901f\u5ea6\u3092\u304a\u3088\u305d2\u500d\u306b\u5897\u52a0\u3055\u305b\u3001\u540c\u3058\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u3067\u6ce8\u5165\u91cf\u309250%\u524a\u6e1b\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u540c\u7b49\u306e\u611f\u5ea6\uff08\u30d4\u30fc\u30af\u9ad8\u3055\uff09\u304c\u7dad\u6301\u3055\u308c\u307e\u3059\u3002\u6ce8\u5165\u91cf\u3092\u6e1b\u3089\u3059\u3053\u3068\u306b\u306f\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3092\u4f4e\u6e1b\u3059\u308b\u3068\u3044\u3046\u4ed8\u52a0\u7684\u306a\u30e1\u30ea\u30c3\u30c8\u3082\u3042\u308a\u3001\u6ce8\u5165\u53e3\u3068\u30ab\u30e9\u30e0\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u304b\u304b\u308b\u30b3\u30b9\u30c8\u3068\u6642\u9593\u3092\u524a\u6e1b\u3067\u304d\u307e\u3059\u3002<br>\u4e00\u65b9\u3001<strong>\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u5206\u6790\u30e1\u30bd\u30c3\u30c9<\/strong>\u306e\u5909\u63db\u306f\u3088\u308a\u8907\u96d1\u3067\u3001\u8ffd\u52a0\u306e\u5909\u66f4\u304c\u5fc5\u8981\u3067\u3059\u3002\u6c34\u7d20\u4f7f\u7528\u6642\u306b\u540c\u3058\u30d4\u30fc\u30af\u6eb6\u51fa\u9806\u5e8f\u3092\u7dad\u6301\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u6607\u6e29\u901f\u5ea6\u3082\u5909\u66f4\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3092\u884c\u308f\u306a\u3044\u3068\u3001\u6210\u5206\u304c\u7570\u306a\u308b\u6642\u9593\u306b\u6eb6\u51fa\u3057\u3001\u6eb6\u51fa\u9806\u5e8f\u304c\u5909\u308f\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u540c\u3058\u6eb6\u51fa\u6e29\u5ea6\u3067\u6eb6\u51fa\u3055\u305b\u308b\u306b\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u6607\u6e29\u901f\u5ea6\u306e\u5909\u66f4\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u304a\u304a\u3088\u305d\u306e\u76ee\u5b89\u3068\u3057\u3066\u3001\u7dda\u901f\u5ea6\u30922\u500d\u306b\u3059\u308b\u5834\u5408\u3001\u7b49\u6e29\u4fdd\u6301\u6642\u9593\u3092\u534a\u5206\u306b\u77ed\u7e2e\u3057\u3001\u6607\u6e29\u901f\u5ea6\u30922\u500d\u306b\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u3067\u3001\u534a\u5206\u306e\u6642\u9593\u3067\u540c\u7b49\u306e\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u8a08\u7b97\u306f\u624b\u52d5\u3067\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001\u3088\u308a\u8907\u96d1\u306a\u30e1\u30bd\u30c3\u30c9\u306b\u306f\u30a6\u30a7\u30d6\u4e0a\u3067\u5229\u7528\u3067\u304d\u308b\u7121\u6599\u30c4\u30fc\u30eb\u304c\u5f79\u7acb\u3061\u307e\u3059\u3002\u307e\u305f\u3001<a href=\"https:\/\/www.restek.com\/contact-us\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/contact-us\" target=\"_blank\" rel=\"noopener\">Restek<\/a>\u306a\u3069\u306e\u30e1\u30fc\u30ab\u30fc\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u306b\u76f8\u8ac7\u3057\u3001\u65b0\u3057\u3044\u8a2d\u5b9a\u3092\u6c7a\u3081\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d8\u30ea\u30a6\u30e0\u306e\u30b3\u30b9\u30c8\u304c\u6025\u4e0a\u6607\u3057\u3001\u5165\u624b\u304c\u56f0\u96e3\u306b\u306a\u308b\u4e2d\u3001GC\u3092\u4f7f\u7528\u3059\u308b\u591a\u304f\u306e\u30e9\u30dc\u304c\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u5207\u308a\u66ff\u3048\u3092\u691c\u8a0e\u3057\u3066\u3044\u307e\u3059\u3002\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u9ad8\u5727\u6c34\u7d20\u30ac\u30b9\u30dc\u30f3\u30d9\u3068\u6bd4\u8f03\u3057\u3066\u5b89\u5168\u304b\u3064\u30b3\u30b9\u30c8\u52b9\u7387\u3088\u304f\u30aa\u30f3\u30c7\u30de\u30f3\u30c9\u3067\u6c34\u7d20\u3092\u4f9b\u7d66\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u6c34\u7d20\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u30d8\u30ea\u30a6\u30e0\u306e2\u500d\u306e\u901f\u3055\u3067\u52b9\u7387\u7684\u306a\u5206\u96e2\u304c\u53ef\u80fd\u3068\u306a\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3068\u30e9\u30dc\u5168\u4f53\u306e\u751f\u7523\u6027\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">References<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>T. Newcomb, Time NewsFeed (August 23, 2012).&nbsp;<a href=\"http:\/\/newsfeed.time.com\/2012\/08\/23\/theres-a-helium-shortage-on-and-its-affecting-more-than-just-balloons\/#the-government\" target=\"_blank\" rel=\"noreferrer noopener\">http:\/\/newsfeed.time.com\/2012\/08\/23\/theres-a-helium-shortage-on-and-its-affecting-more-than-just-balloons\/#the-government<\/a>&nbsp;(accessed November 1, 2012).<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u203b\u672c\u8a18\u4e8b\u306f&nbsp;Petro Industry News \u306b\u63b2\u8f09\u3055\u308c\u305f\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u8ee2\u8f09\u3067\u3059\u3002 GC\u30e9\u30dc\u306e\u591a\u304f\u304c\u30d8\u30ea\u30a6\u30e0\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3057\u3066\u3044\u308b\u306e\u306f\u3001\u7a92\u7d20\u3088\u308a\u9ad8\u3044\u7dda\u901f\u5ea6\u3067\u3082\u826f\u597d\u306a\u5206\u96e2\u52b9\u7387\u304c\u5f97\u3089\u308c\u3001\u6c34\u7d20\u3068\u6bd4\u3079\u3066\u5b89\u5168\u306b\u6271\u3048\u308b\u305f\u3081\u3067\u3059\u3002\u3057\u304b\u3057\u30d8\u30ea\u30a6\u30e0\u306f\u5e0c\u5c11\u306a\u5929\u7136\u8cc7\u6e90\u3067\u3042\u308a\u3001\u5165\u624b\u304c\u307e\u3059\u307e\u3059\u56f0\u96e3\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u73fe\u5728\u306e\u4f9b\u7d66\u4e0d\u8db3\u306b\u3088\u308a\u4fa1\u683c\u306f\u5927\u5e45\u306b\u4e0a\u6607\u3057\u3001\u5fc5\u8981\u306a\u3068\u304d\u306b\u5165\u624b\u3067\u304d\u306a\u3044\u30b1\u30fc\u30b9\u3082\u751f\u3058\u3066\u3044\u307e\u3059\u3002\u30d8\u30ea\u30a6\u30e0\u306f\u5b87\u5b99\u306b\u306f\u8c4a\u5bcc\u306b\u5b58\u5728\u3057\u307e\u3059\u304c\u3001\u5730\u7403\u4e0a\u3067\u306f\u5929\u7136\u30ac\u30b9\u306e\u5206\u7559\u306b\u3088\u3063\u3066\u88fd\u9020\u3055\u308c\u308b\u305f\u3081\u975e\u5e38\u306b\u5e0c\u5c11\u3067\u3059\u3002\u30a2\u30e1\u30ea\u30ab\u306f\u4e3b\u8981\u306a\u751f\u7523\u56fd\u3067\u3059\u304c\u3001\u305d\u306e\u4e3b\u8981\u5099\u84c4\u3067\u3042\u308b\u7c73\u56fd\u56fd\u5bb6\u30d8\u30ea\u30a6\u30e0\u5099\u84c4\uff08\u4e16\u754c\u4f9b\u7d66\u91cf\u306e\u7d0430%\u3092\u5360\u3081\u308b\uff09\u306f2018\u5e74\u307e\u3067\u306b\u67af\u6e07\u3059\u308b\u3068\u4e88\u6e2c\u3055\u308c\u3066\u3044\u307e\u3057\u305f [1]\u3002\u4ed6\u306e\u4f9b\u7d66\u6e90\u306b\u3088\u308b\u4e0d\u8db3\u89e3\u6d88\u3082\u898b\u8fbc\u3081\u306a\u3044\u3053\u3068\u304b\u3089\u3001\u591a\u304f\u306eGC\u30e9\u30dc\u304c\u4ee3\u66ff\u624b\u6bb5\u3068\u3057\u3066\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u5207\u308a\u66ff\u3048\u3092\u691c\u8a0e\u3057\u3066\u3044\u307e\u3059\u3002\u6c34\u7d20\u306f\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u3001\u4f4e\u30b3\u30b9\u30c8\u3001\u5b89\u5b9a\u3057\u305f\u4f9b\u7d66\u3068\u3044\u3046\u70b9\u3067\u512a\u308c\u305f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u9078\u629e\u80a2\u3067\u3059\u304c\u3001\u53ef\u71c3\u6027\u304c\u3042\u308b\u305f\u3081\u5c0e\u5165\u306b\u306f\u5b89\u5168\u9762\u3078\u306e\u5341\u5206\u306a\u914d\u616e\u304c\u5fc5\u8981\u3067\u3059\u3002\u5b89\u5168\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u3092\u6d3b\u7528\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306e\u624b\u9806\u3092\u6b63\u3057\u304f\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001\u751f\u7523\u6027\u5411\u4e0a\u3068\u30b3\u30b9\u30c8\u524a\u6e1b\u306e\u6069\u6075\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 \u5b89\u5168\u6027\u306b\u95a2\u3059\u308b\u6ce8\u610f\u70b9 \u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u5207\u308a\u66ff\u3048\u3067\u6700\u521d\u306b\u8003\u616e\u3059\u3079\u304d\u306f\u3001\u5b89\u5168\u4e0a\u306e\u30ea\u30b9\u30af\u3092\u6b63\u3057\u304f\u7406\u89e3\u3057\u3001\u9069\u5207\u306b\u7ba1\u7406\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u9069\u5207\u306a\u6a5f\u5668\u3068\u904b\u7528\u65b9\u6cd5\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3001\u30ea\u30b9\u30af\u3092\u5927\u5e45\u306b\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002 \u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u306b\u3088\u308b\u8caf\u8535\u30ea\u30b9\u30af\u306e\u6700\u5c0f\u5316 \u9ad8\u5727\u30ac\u30b9\u30dc\u30f3\u30d9\u304c\u901a\u5e3850 L\u30fb200\u6c17\u5727\u306e\u6c34\u7d20\u3092\u8caf\u8535\u3059\u308b\u306e\u306b\u5bfe\u3057\u3001\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u306e\u8caf\u8535\u91cf\u306f\u6700\u592760 mL\u30fb7\u6c17\u5727\u4ee5\u4e0b\u306b\u3068\u3069\u307e\u308a\u307e\u3059\u3002\u30aa\u30f3\u30c7\u30de\u30f3\u30c9\u3067\u7d99\u7d9a\u7684\u306b\u6c34\u7d20\u3092\u4f9b\u7d66\u3067\u304d\u308b\u4e00\u65b9\u3001\u8caf\u8535\u91cf\u304c\u975e\u5e38\u306b\u5c11\u306a\u3044\u305f\u3081\u3001\u5b89\u5168\u6027\u304c\u5927\u5e45\u306b\u5411\u4e0a\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u304b\u3089\u306e\u6d41\u91cf\u306f\u5236\u5fa1\u3055\u308c\u3066\u304a\u308a\u3001\u4e00\u822c\u7684\u306a\u6a5f\u7a2e\u3067\u306e\u6700\u5927\u6d41\u91cf\u306f\u7d04500 mL\/min\u3067\u3059\u3002\u3053\u308c\u306f\u3001\u4e00\u822c\u7684\u306aGC\u30aa\u30fc\u30d6\u30f3\u5185\u3067\u6c34\u7d20\u306e\u7206\u767a\u4e0b\u9650\u754c\uff08LEL\uff09\u306b\u9054\u3059\u308b\u306e\u306b\u5fc5\u8981\u306a\u6d41\u91cf\uff082 L\/min\uff09\u3092\u5927\u5e45\u306b\u4e0b\u56de\u308b\u5024\u3067\u3059\u3002\u30ea\u30fc\u30af\u30bb\u30f3\u30b5\u30fc\u3068\u81ea\u52d5\u30b7\u30e3\u30c3\u30c8\u30aa\u30d5\u6a5f\u80fd\u3082\u5185\u8535\u3055\u308c\u3066\u304a\u308a\u3001\u7570\u5e38\u3092\u691c\u77e5\u3059\u308b\u3068\u5373\u5ea7\u306b\u505c\u6b62\u3057\u307e\u3059\u3002\u30d8\u30ea\u30a6\u30e0\u30b3\u30b9\u30c8\u306e\u6025\u9a30\u304c\u7d9a\u304f\u4e2d\u3001\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u306f\u6295\u8cc7\u56de\u53ce\u3082\u65e9\u304f\u3001\u9ad8\u5727\u30ac\u30b9\u30dc\u30f3\u30d9\u306b\u4f34\u3046\u5b89\u5168\u30ea\u30b9\u30af\u3092\u6839\u672c\u304b\u3089\u6392\u9664\u3057\u306a\u304c\u3089\u5b89\u5b9a\u3057\u305f\u30ac\u30b9\u4f9b\u7d66\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002 \u30d5\u30ed\u30fc\u5236\u5fa1\u5206\u6790\u306b\u3088\u308b\u30ea\u30fc\u30af\u6642\u306e\u30ea\u30b9\u30af\u4f4e\u6e1b GC\u306e\u6d41\u91cf\u5236\u5fa1\u306b\u306f\u5b9a\u5727\u30e2\u30fc\u30c9\u3068\u5b9a\u6d41\u91cf\u30e2\u30fc\u30c9\u304c\u9078\u629e\u3067\u304d\u307e\u3059\u304c\u3001\u6c34\u7d20\u4f7f\u7528\u6642\u306f\u5b9a\u6d41\u91cf\u30e2\u30fc\u30c9\u3067\u306e\u904b\u8ee2\u304c\u6700\u5584\u306e\u9078\u629e\u80a2\u3067\u3059\u3002\u4e07\u304c\u4e00\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u304c\u6ce8\u5165\u53e3\u4ed8\u8fd1\u3067\u6298\u308c\u305f\u5834\u5408\u3001\u96fb\u5b50\u5727\u529b\u5236\u5fa1\uff08EPC\uff09\u3092\u6301\u3064GC\u306f\u30b7\u30b9\u30c6\u30e0\u5185\u306e\u5727\u529b\u7570\u5e38\u3092\u5373\u5ea7\u306b\u691c\u77e5\u3057\u3001\u81ea\u52d5\u7684\u306b\u30b9\u30bf\u30f3\u30d0\u30a4\u30e2\u30fc\u30c9\u306b\u79fb\u884c\u3057\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u306b\u653e\u51fa\u3055\u308c\u308b\u6c34\u7d20\u306f\u30a4\u30f3\u30ec\u30c3\u30c8\u304a\u3088\u3073\u30ab\u30e9\u30e0\u5185\u90e8\u306e\u4f53\u7a4d\u5206\u306e\u307f\u306b\u9650\u3089\u308c\u308b\u305f\u3081\u3001\u5371\u967a\u306a\u6fc3\u5ea6\u3078\u306e\u5230\u9054\u30ea\u30b9\u30af\u306f\u6975\u3081\u3066\u4f4e\u304f\u6291\u3048\u3089\u308c\u307e\u3059\u3002 \u7570\u7a2e\u30ac\u30b9\u691c\u77e5\u30b7\u30b9\u30c6\u30e0\u306b\u3088\u308b\u591a\u5c64\u9632\u5fa1 \u3088\u308a\u9ad8\u3044\u5b89\u5168\u6027\u304c\u6c42\u3081\u3089\u308c\u308b\u74b0\u5883\u3067\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u5185\u306e\u7a7a\u6c17\u3092\u5e38\u6642\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3057\u3066\u7570\u7a2e\u30ac\u30b9\uff08\u30d8\u30ea\u30a6\u30e0\u3084\u6c34\u7d20\u306a\u3069\uff09\u306e\u5b58\u5728\u3092\u691c\u77e5\u3059\u308b\u30b7\u30b9\u30c6\u30e0\u306e\u5c0e\u5165\u3082\u6709\u52b9\u3067\u3059\u3002\u30ac\u30b9\u767a\u751f\u88c5\u7f6e\u30fb\u30d5\u30ed\u30fc\u5236\u5fa1\u30fb\u30ac\u30b9\u691c\u77e5\u30b7\u30b9\u30c6\u30e0\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u591a\u5c64\u7684\u306a\u5b89\u5168\u5bfe\u7b56\u304c\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002 MXT\u30e1\u30bf\u30eb\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u3088\u308b\u7269\u7406\u7684\u30ea\u30b9\u30af\u306e\u6392\u9664 \u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ab\u30e9\u30e0\u306e\u7834\u640d\u30ea\u30b9\u30af\u3092\u30bc\u30ed\u306b\u3059\u308b\u306b\u306f\u3001Restek\u306eMXT\u30e1\u30bf\u30eb\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u304c\u6700\u3082\u78ba\u5b9f\u306a\u89e3\u6c7a\u7b56\u3067\u3059\u3002\u7269\u7406\u7684\u306b\u6298\u308c\u306a\u3044\u5805\u7262\u306a\u69cb\u9020\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u7834\u640d\u306b\u8d77\u56e0\u3059\u308b\u6c34\u7d20\u6f0f\u6d29\u306e\u30ea\u30b9\u30af\u3092\u6839\u672c\u304b\u3089\u6392\u9664\u3067\u304d\u307e\u3059\u3002MXT\u30ab\u30e9\u30e0\u306f\u6700\u9ad8450 \u00b0C\u307e\u3067\u306e\u9ad8\u6e29\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\uff08\u6a21\u64ec\u84b8\u7559\u30fb\u30d0\u30a4\u30aa\u30c7\u30a3\u30fc\u30bc\u30eb\u5206\u6790\u306a\u3069\uff09\u3067\u9577\u5e74\u306e\u5b9f\u7e3e\u3092\u6301\u3064\u4e00\u65b9\u3001\u4f4e\u6e29\u5206\u6790\u3067\u3082\u512a\u308c\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u7279\u306bSiltek\u51e6\u7406\u3092\u65bd\u3057\u305f\u9ad8\u4e0d\u6d3b\u6027\u5316\u30b0\u30ec\u30fc\u30c9\u306f\u3001\u6d3b\u6027\u5316\u306b\u3088\u308b\u5206\u6790\u3078\u306e\u60aa\u5f71\u97ff\u3092\u6392\u9664\u3057\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u826f\u597d\u306a\u5206\u6790\u7d50\u679c\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002 \u30e1\u30ea\u30c3\u30c8\u3068\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3 \u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u306b\u304a\u3051\u308b\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u512a\u4f4d\u6027 \u6c34\u7d20\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u6700\u5927\u306e\u30e1\u30ea\u30c3\u30c8\u306f\u3001\u5206\u6790\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3067\u304d\u308b\u3053\u3068\u3067\u3059\u3002\u5206\u96e2\u5ea6\u306b\u308f\u305a\u304b\u306a\u4f4e\u4e0b\u304c\u751f\u3058\u308b\u5834\u5408\u304c\u3042\u308b\u3082\u306e\u306e\u3001\u73fe\u5b9f\u7684\u306b\u5206\u6790\u6642\u9593\u30921.5\u301c2\u500d\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3068\u751f\u7523\u6027\u3092\u5927\u304d\u304f\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 \u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7a2e\u985e\u3068\u52b9\u7387\u30fb\u7dda\u901f\u5ea6\u306e\u95a2\u4fc2 \u4e00\u822c\u7684\u306a\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306evan Deemter\u30d7\u30ed\u30c3\u30c8\u3092\u78ba\u8a8d\u3059\u308b\u3068\u3001\u3053\u306e\u70b9\u306f\u660e\u3089\u304b\u3067\u3059\uff08Figure 1\uff09\u3002\u7a92\u7d20\u306f\u6700\u3082\u9ad8\u3044\u52b9\u7387\uff08\u6700\u77ed\u306e\u7406\u8ad6\u6bb5\u76f8\u5f53\u9ad8\u3055\uff09\u3092\u793a\u3057\u307e\u3059\u304c\u3001\u6700\u5927\u52b9\u7387\u304c\u5f97\u3089\u308c\u308b\u306e\u306f\u7d0410 cm\/sec\u3068\u3044\u3046\u975e\u5e38\u306b\u4f4e\u3044\u7dda\u901f\u5ea6\u306b\u9650\u3089\u308c\u3001\u7dda\u901f\u5ea6\u3092\u4e0a\u3052\u308b\u3068\u52b9\u7387\u306f\u6025\u6fc0\u306b\u4f4e\u4e0b\u3057\u307e\u3059\u3002\u30d8\u30ea\u30a6\u30e0\u306f\u52b9\u7387\u304c\u3084\u3084\u52a3\u308b\u3082\u306e\u306e\u3001\u3088\u308a\u5b9f\u7528\u7684\u306a\u7dda\u901f\u5ea6\u57df\u3067\u4f7f\u7528\u3067\u304d\uff08\u6700\u9069\u306f\u7d0425 cm\/sec\u3001\u9ad8\u7dda\u901f\u5ea6\u3067\u306e\u52b9\u7387\u4f4e\u4e0b\u3082\u7de9\u3084\u304b\uff09\u3001\u6271\u3044\u3084\u3059\u3044\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3067\u3059\u3002\u3057\u304b\u3057\u6700\u3082\u512a\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3092\u793a\u3059\u306e\u306f\u6c34\u7d20\u3067\u3059\u3002\u6700\u5927\u52b9\u7387\u306f\u30d8\u30ea\u30a6\u30e0\u3068\u540c\u7b49\u3067\u3042\u308a\u306a\u304c\u3089\u3001\u306f\u308b\u304b\u306b\u5e83\u3044\u7dda\u901f\u5ea6\u57df\u3067\u826f\u597d\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u6c34\u7d20\u4f7f\u7528\u6642\u306e\u6700\u9069\u7dda\u901f\u5ea6\u306f\u7d0440\u301c45 cm\/sec\u3067\u3042\u308a\u3001\u30d8\u30ea\u30a6\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u5206\u6790\u6642\u9593\u304c\u5927\u5e45\u306b\u77ed\u7e2e\u3055\u308c\u3001\u591a\u304f\u306e\u5834\u5408\u3067\u534a\u5206\u306e\u6642\u9593\u3067\u306e\u6e2c\u5b9a\u304c\u53ef\u80fd\u3067\u3059\u3002 \u70ad\u5316\u6c34\u7d20\u6df7\u5408\u7269\u306e\u5206\u6790\u4e8b\u4f8b\u306b\u3088\u308b\u5b9f\u8a3c \u7406\u8ad6\u7684\u306a\u30e1\u30ea\u30c3\u30c8\u3092\u5b9f\u969b\u306e\u30c7\u30fc\u30bf\u3067\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002Figure 2\u306f\u3001\u540c\u4e00\u306eGC\u30b7\u30b9\u30c6\u30e0\u3092\u4f7f\u7528\u3057\u3066\u30d8\u30ea\u30a6\u30e0\u3068\u6c34\u7d20\u3067\u305d\u308c\u305e\u308c\u70ad\u5316\u6c34\u7d20\u6df7\u5408\u7269\u3092\u5206\u6790\u3057\u3001\u7d50\u679c\u3092\u6bd4\u8f03\u3057\u305f\u3082\u306e\u3067\u3059\u3002\u6c34\u7d20\u4f7f\u7528\u6642\u306f\u30d8\u30ea\u30a6\u30e0\u306e2\u500d\u306e\u7dda\u901f\u5ea6\uff0846 cm\/sec\uff09\u3067\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u5168\u6210\u5206\u304c\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u6642\u306e\u534a\u5206\u306e\u6642\u9593\u3067\u6eb6\u51fa\u3057\u307e\u3057\u305f\u3002\u6ce8\u76ee\u3059\u3079\u304d\u70b9\u3068\u3057\u3066\u3001\u7dda\u901f\u5ea6\u30922\u500d\u306b\u3057\u3066\u3082\u5404\u6210\u5206\u9593\u306e\u5206\u96e2\u306f\u826f\u597d\u306b\u7dad\u6301\u3055\u308c\u3066\u304a\u308a\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u52b9\u7387\u3078\u306e\u60aa\u5f71\u97ff\u306f\u307b\u3068\u3093\u3069\u8a8d\u3081\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u5206\u6790\u6642\u9593\u304c\u534a\u5206\u306b\u306a\u308b\u3068\u30d4\u30fc\u30af\u5e45\u3082\u534a\u5206\u306b\u306a\u308b\u305f\u3081\u3001\u30d4\u30fc\u30af\u9ad8\u3055\u306f2\u500d\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u611f\u5ea6\u304c\u5411\u4e0a\u3057\u3001\u3088\u308a\u5c11\u306a\u3044\u6ce8\u5165\u91cf\u3067\u3082\u540c\u7b49\u306e\u691c\u51fa\u611f\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u6ce8\u5165\u91cf\u306e\u524a\u6e1b\u306f\u30ab\u30e9\u30e0\u3084\u6ce8\u5165\u53e3\u306e\u6c5a\u67d3\u4f4e\u6e1b\u306b\u3082\u3064\u306a\u304c\u308a\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30b3\u30b9\u30c8\u306e\u524a\u6e1b\u3068\u3044\u3046\u4ed8\u52a0\u7684\u306a\u30e1\u30ea\u30c3\u30c8\u3082\u751f\u307e\u308c\u307e\u3059\u3002\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u30e1\u30ea\u30c3\u30c8\u306f\u5206\u6790\u901f\u5ea6\u306e\u5411\u4e0a\u306b\u3068\u3069\u307e\u3089\u305a\u3001\u611f\u5ea6\u30fb\u30b3\u30b9\u30c8\u30fb\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u89b3\u70b9\u3067\u3082\u591a\u304f\u306e\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u3053\u308c\u3089\u306e\u30e1\u30ea\u30c3\u30c8\u3092\u6700\u5927\u9650\u306b\u6d3b\u304b\u3059\u305f\u3081\u306b\u306f\u3001\u5b9f\u88c5\u524d\u306b\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u3092\u9069\u5207\u306b\u884c\u3046\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002 \u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u30e1\u30bd\u30c3\u30c9\u5909\u63db \u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u3067\u306f\u3001\u6eb6\u51fa\u6e29\u5ea6\u3078\u306e\u5f71\u97ff\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u7b49\u6e29\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306e\u5834\u5408\u3001\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u6c34\u7d20\u3078\u306e\u5909\u63db\u306f\u6bd4\u8f03\u7684\u30b7\u30f3\u30d7\u30eb\u3067\u3059\u3002\u7dda\u901f\u5ea6\u3092\u304a\u3088\u305d2\u500d\u306b\u5897\u52a0\u3055\u305b\u3001\u540c\u3058\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u3067\u6ce8\u5165\u91cf\u309250%\u524a\u6e1b\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u540c\u7b49\u306e\u611f\u5ea6\uff08\u30d4\u30fc\u30af\u9ad8\u3055\uff09\u304c\u7dad\u6301\u3055\u308c\u307e\u3059\u3002\u6ce8\u5165\u91cf\u3092\u6e1b\u3089\u3059\u3053\u3068\u306b\u306f\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3092\u4f4e\u6e1b\u3059\u308b\u3068\u3044\u3046\u4ed8\u52a0\u7684\u306a\u30e1\u30ea\u30c3\u30c8\u3082\u3042\u308a\u3001\u6ce8\u5165\u53e3\u3068\u30ab\u30e9\u30e0\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u304b\u304b\u308b\u30b3\u30b9\u30c8\u3068\u6642\u9593\u3092\u524a\u6e1b\u3067\u304d\u307e\u3059\u3002\u4e00\u65b9\u3001\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306e\u5909\u63db\u306f\u3088\u308a\u8907\u96d1\u3067\u3001\u8ffd\u52a0\u306e\u5909\u66f4\u304c\u5fc5\u8981\u3067\u3059\u3002\u6c34\u7d20\u4f7f\u7528\u6642\u306b\u540c\u3058\u30d4\u30fc\u30af\u6eb6\u51fa\u9806\u5e8f\u3092\u7dad\u6301\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u6607\u6e29\u901f\u5ea6\u3082\u5909\u66f4\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3092\u884c\u308f\u306a\u3044\u3068\u3001\u6210\u5206\u304c\u7570\u306a\u308b\u6642\u9593\u306b\u6eb6\u51fa\u3057\u3001\u6eb6\u51fa\u9806\u5e8f\u304c\u5909\u308f\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u540c\u3058\u6eb6\u51fa\u6e29\u5ea6\u3067\u6eb6\u51fa\u3055\u305b\u308b\u306b\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u6607\u6e29\u901f\u5ea6\u306e\u5909\u66f4\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u304a\u304a\u3088\u305d\u306e\u76ee\u5b89\u3068\u3057\u3066\u3001\u7dda\u901f\u5ea6\u30922\u500d\u306b\u3059\u308b\u5834\u5408\u3001\u7b49\u6e29\u4fdd\u6301\u6642\u9593\u3092\u534a\u5206\u306b\u77ed\u7e2e\u3057\u3001\u6607\u6e29\u901f\u5ea6\u30922\u500d\u306b\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u3067\u3001\u534a\u5206\u306e\u6642\u9593\u3067\u540c\u7b49\u306e\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u8a08\u7b97\u306f\u624b\u52d5\u3067\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001\u3088\u308a\u8907\u96d1\u306a\u30e1\u30bd\u30c3\u30c9\u306b\u306f\u30a6\u30a7\u30d6\u4e0a\u3067\u5229\u7528\u3067\u304d\u308b\u7121\u6599\u30c4\u30fc\u30eb\u304c\u5f79\u7acb\u3061\u307e\u3059\u3002\u307e\u305f\u3001Restek\u306a\u3069\u306e\u30e1\u30fc\u30ab\u30fc\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u306b\u76f8\u8ac7\u3057\u3001\u65b0\u3057\u3044\u8a2d\u5b9a\u3092\u6c7a\u3081\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002 \u307e\u3068\u3081 \u30d8\u30ea\u30a6\u30e0\u306e\u30b3\u30b9\u30c8\u304c\u6025\u4e0a\u6607\u3057\u3001\u5165\u624b\u304c\u56f0\u96e3\u306b\u306a\u308b\u4e2d\u3001GC\u3092\u4f7f\u7528\u3059\u308b\u591a\u304f\u306e\u30e9\u30dc\u304c\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306e\u5207\u308a\u66ff\u3048\u3092\u691c\u8a0e\u3057\u3066\u3044\u307e\u3059\u3002\u6c34\u7d20\u767a\u751f\u88c5\u7f6e\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u9ad8\u5727\u6c34\u7d20\u30ac\u30b9\u30dc\u30f3\u30d9\u3068\u6bd4\u8f03\u3057\u3066\u5b89\u5168\u304b\u3064\u30b3\u30b9\u30c8\u52b9\u7387\u3088\u304f\u30aa\u30f3\u30c7\u30de\u30f3\u30c9\u3067\u6c34\u7d20\u3092\u4f9b\u7d66\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u6c34\u7d20\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u30d8\u30ea\u30a6\u30e0\u306e2\u500d\u306e\u901f\u3055\u3067\u52b9\u7387\u7684\u306a\u5206\u96e2\u304c\u53ef\u80fd\u3068\u306a\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3068\u30e9\u30dc\u5168\u4f53\u306e\u751f\u7523\u6027\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002 References<\/p>\n","protected":false},"author":19,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2249],"post-badge":[],"resource-type":[],"product-library":[2534,2516],"resource-technique":[2332],"ppma_author":[439,696],"class_list":["post-94318","post","type-post","status-publish","format-standard","hentry","category-articles-ja","industries-application-energia","product-library-purificatori-di-gas","product-library-prodotti-per-gascromatografia","resource-technique-gascromatografia-gc"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2249,"label":"Energia"}],"product-library":[{"value":2534,"label":"Purificatori di Gas"},{"value":2516,"label":"Prodotti per Gascromatografia"}],"resource-technique":[{"value":2332,"label":"Gascromatografia (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jaap de Zeeuw","author_link":"https:\/\/discover.restek.com\/ja\/author\/jaap-de-zeeuw\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":439,"user_id":19,"is_guest":0,"slug":"jaap-de-zeeuw","display_name":"Jaap de Zeeuw","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg"},"author_category":"1","first_name":"Jaap","last_name":"de Zeeuw","user_url":"https:\/\/www.linkedin.com\/in\/jaap-de-zeeuw-ba102a7\/","job_title":"GC Consultant","description":"Jaap is a world-renowned chromatographer with over 40 years of experience, including 15 years with Restek and 27 years with Varian\/Chrompack prior to joining Restek. Throughout his career, Jaap has focused the chromatographic challenges of industrial analysis. For his 1979 graduation from The Institute for Higher Education, where he specialized in chemistry, Jaap authored a paper titled \"The Challenge of Coating Flexible Fused Silica Capillary Columns\" and has since distinguished himself as an authority on the subject. Jaap has been directly involved with the creation of numerous chemically bonded columns, including the first bonded PEG column and the stabilized PLOT columns widely used in the petrochemical arena. He has also helped develop new techniques, such as fast GC-MS using vacuum GC technology (low-pressure GC or LPGC). Over his innovative career, he has filed several patents for his work. Based out of the Netherlands, Jaap is extensively published and regularly travels internationally to share his knowledge. After retiring from Restek, Jaap founded CreaVisions, where he works as a GC Consultant and teaches master classes on key GC topics as well as on creativity in science."},{"term_id":696,"user_id":0,"is_guest":1,"slug":"jim-whitford","display_name":"Jim Whitford","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Jim","last_name":"Whitford","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94318","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=94318"}],"version-history":[{"count":9,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94318\/revisions"}],"predecessor-version":[{"id":96147,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/94318\/revisions\/96147"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=94318"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=94318"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=94318"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=94318"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=94318"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=94318"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=94318"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=94318"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=94318"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}