{"id":95194,"date":"2026-05-19T08:01:33","date_gmt":"2026-05-19T08:01:33","guid":{"rendered":"https:\/\/discover.restek.com\/?p=95194"},"modified":"2026-06-08T07:46:32","modified_gmt":"2026-06-08T07:46:32","slug":"eprw","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/events-ja\/gnot5716-unv\/eprw","title":{"rendered":"EPRW, Rotterdam, The Netherlands, June 8-12"},"content":{"rendered":"<style>.kb-image95194_df3c39-5c .kb-image-has-overlay:after{opacity:0.3;}.kb-image95194_df3c39-5c img.kb-img, .kb-image95194_df3c39-5c .kb-img img{object-position:52% 61%;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image95194_df3c39-5c alignfull\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"751\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/EPRW-Landing-Page-scaled.jpg\" alt=\"\" class=\"kb-img wp-image-95196\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/EPRW-Landing-Page-scaled.jpg 2560w, https:\/\/discover.restek.com\/wp-content\/uploads\/EPRW-Landing-Page-300x88.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/EPRW-Landing-Page-1024x300.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/EPRW-Landing-Page-768x225.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/EPRW-Landing-Page-1536x450.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/EPRW-Landing-Page-2048x601.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-weight: 500;\">Come and meet us at the&nbsp;Postillion Hotel &amp; Convention Centre at <span style=\"font-weight: 900;\">booth 15!&nbsp;<\/span><\/h2>\n\n\n\n<div style=\"height:13px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:17px\">We\u2019re&nbsp;off to Rotterdam for&nbsp;the&nbsp;<strong>16<sup>th<\/sup>&nbsp;European Pesticide Residue Workshop<\/strong>,&nbsp;the&nbsp;key event dedicated to the latest developments in pesticide residue analysis in food,&nbsp;monitoring&nbsp;and control.&nbsp;Drop by booth 15 to:&nbsp;<\/p>\n\n\n\n<div style=\"height:18px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"line-height:2.3\">Discover the possibilities of our new <a href=\"https:\/\/discover.restek.com\/rmx\/\" data-type=\"page\" data-id=\"80063\">RMX column<\/a> and explore the future of GC.<br><\/li>\n\n\n\n<li style=\"line-height:2.3\">Play our&nbsp;&#8220;Guess the Length of the GC Column&#8221; game for a chance to win&nbsp;fantastic&nbsp;Restek prizes!<br><\/li>\n\n\n\n<li style=\"line-height:2.3\">Experience a demo to learn&nbsp;how \n<ul class=\"wp-block-list\">\n<li style=\"line-height:2.3\">our&nbsp;<a href=\"https:\/\/ez.restek.com\/\" data-type=\"link\" data-id=\"https:\/\/ez.restek.com\/\" target=\"_blank\" rel=\"noopener\"><em>EZ<\/em>&nbsp;software&nbsp;suite<\/a>&nbsp;could allow you to perform method development in minutes.<\/li>\n\n\n\n<li style=\"line-height:2.3\">The&nbsp;new&nbsp;<a href=\"https:\/\/tools.restek.com\/\" target=\"_blank\" rel=\"noopener\">Restek&nbsp;Rerefence&nbsp;standards tool<\/a> streamlines searching for the compounds you need&nbsp;<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li style=\"line-height:2.3\">Meet our&nbsp;knowledgeable&nbsp;LC, GC, Standards, and Sample Prep specialists: they will be available to answer your questions and help you&nbsp;optimize&nbsp;your analyses with our flagship <a href=\"#ProductsSolutions\" data-type=\"internal\" data-id=\"#ProductsSolutions\">products and analytical solutions<\/a>.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:49px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kadence-column95194_13b432-fd > .kt-inside-inner-col,.kadence-column95194_13b432-fd > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_13b432-fd > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_13b432-fd > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_13b432-fd > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_13b432-fd > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_13b432-fd{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_13b432-fd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_13b432-fd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_13b432-fd\"><div class=\"kt-inside-inner-col\"><style>.wp-block-kadence-advancedbtn.kb-btns95194_9543d7-85{gap:var(--global-kb-gap-sm, 1rem);justify-content:center;align-items:center;}.kt-btns95194_9543d7-85 .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_9543d7-85 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_9543d7-85 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_9543d7-85 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_9543d7-85 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_9543d7-85 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_9543d7-85 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_9543d7-85 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_9543d7-85\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_63daa3-0e.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_63daa3-0e kt-btn-size-large kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"#presentations\"><span class=\"kt-btn-inner-text\"><strong>Technical Presentation<\/strong>s<\/span><\/a>\n\n<style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_ee4eb3-af.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_ee4eb3-af kt-btn-size-large kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"#ProductsSolutions\"><span class=\"kt-btn-inner-text\"><strong><strong>Featured Products &amp; Analytical Solutions<\/strong><\/strong><\/span><\/a>\n\n<style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_a1732e-56.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn95194_a1732e-56.kb-button{background:var(--global-palette1, #3182CE);border-top-left-radius:3px;border-top-right-radius:3px;border-bottom-right-radius:3px;border-bottom-left-radius:3px;}<\/style><a class=\"kb-button kt-button button kb-btn95194_a1732e-56 kt-btn-size-large kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.eprw2026.com\/\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Learn More about EPRW 2026<\/strong><\/span><\/a><\/div>\n\n\n\n<div style=\"height:80px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-theme-palette-1-color has-text-color has-link-color has-large-font-size wp-elements-c6ee7a4cc7cc35d4da47498cde5fa67c\" id=\"presentations\"><strong>Technical Presentation<\/strong>s<\/h2>\n\n\n\n<div style=\"height:59px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-block-show-more-container95194_c936a0-98 > .kb-show-more-sr-excerpt{position:absolute;width:1px;height:1px;margin:-1px;overflow:hidden;clip:rect(0, 0, 0, 0);white-space:nowrap;}.kb-block-show-more-container95194_c936a0-98 > .wp-block-kadence-advancedbtn{margin-top:1em;}.kb-block-show-more-container95194_c936a0-98 > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(2), .kb-block-show-more-container95194_c936a0-98 > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(2){display:none;}.kb-block-show-more-container95194_c936a0-98 > .wp-block-kadence-column{max-height:145px;overflow-y:hidden;}.kb-block-show-more-container95194_c936a0-98.kb-smc-open > .wp-block-kadence-column{max-height:none;-webkit-mask-image:none;mask-image:none;overflow-y:unset;}.kb-block-show-more-container95194_c936a0-98.kb-smc-open > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(1), .kb-block-show-more-container95194_c936a0-98.kb-smc-open > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(1){display:none;}.kb-block-show-more-container95194_c936a0-98.kb-smc-open > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(2), .kb-block-show-more-container95194_c936a0-98.kb-smc-open > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(2){display:inline-flex;}.kb-block-show-more-container95194_c936a0-98.kb-smc-open > .wp-block-kadence-advancedbtn.kt-force-btn-fullwidth .kt-btn-wrap:nth-child(2){display:block;}<\/style>\n<div class=\"wp-block-kadence-show-more kb-block-show-more-container kb-block-show-more-container95194_c936a0-98\"><div class=\"kb-show-more-sr-excerpt\" aria-live=\"polite\" aria-atomic=\"true\"><\/div><style>.kadence-column95194_c47bb3-95 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_c47bb3-95 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_c47bb3-95 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_c47bb3-95 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_c47bb3-95{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_c47bb3-95 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_c47bb3-95 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_c47bb3-95 kb-show-more-content\"><div class=\"kt-inside-inner-col\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Seminar<\/strong>: <\/strong><\/strong>Unleash Your Performance with the Next Generation GC Column Technology for the GC-MS\/MS analysis of pesticides in difficult food Matrices<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Session Time and Location<\/strong>: Thursday 11 June 2026, 14:10 \u2013 14:45 | Mees Room 1&amp;2, Ground floor&nbsp;&nbsp;<br><strong><strong>Presenter(s)\/Co-Author(s):<\/strong><\/strong>&nbsp;Dr. Javier Arrebola, Colton Myers, Laura Schuetz, Alexander Zahm, Olivier Griffaton<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gas Chromatography is a proven technique for the analysis of pesticide compounds in food matrix. Recent changes in regulations including chlorinated solvent ban, method consolidation for pesticides methods, and reduced volume extraction, and sensitivity requirements has lead to a need for a GC solution that can meet and exceed the detection requirements.&nbsp; In addition, there is a need for matrix resilience and extended lifetime and continued calibration. This presentation will unleash how the latest column deactivation technology and unique formats in GC can address these challenges. Real and challenging food matrices were subjected to analytical testing to demonstrate robustness and resilience of the next generation GC Column, enhancing GC-MS\/MS analysis of fruits, vegetables, cereals, and legumes in a high-throughput Laboratory.<\/p>\n<\/div><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_cb4c24-d2{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns95194_cb4c24-d2 .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_cb4c24-d2 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_cb4c24-d2 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_cb4c24-d2 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_cb4c24-d2 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_cb4c24-d2 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_cb4c24-d2 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_cb4c24-d2 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_cb4c24-d2 kb-show-more-buttons\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_12d91a-af.kb-button{width:initial;}<\/style><button class=\"kb-button kt-button button kb-btn95194_12d91a-af kt-btn-size-small kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\"><span class=\"kt-btn-inner-text\">Show More<\/span><\/button>\n\n<style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_b44c22-59.kb-button{width:initial;}<\/style><button class=\"kb-button kt-button button kb-btn95194_b44c22-59 kt-btn-size-small kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\"><span class=\"kt-btn-inner-text\">Show Less<\/span><\/button><\/div>\n<\/div>\n\n\n\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-block-show-more-container95194_046f4b-34 > .kb-show-more-sr-excerpt{position:absolute;width:1px;height:1px;margin:-1px;overflow:hidden;clip:rect(0, 0, 0, 0);white-space:nowrap;}.kb-block-show-more-container95194_046f4b-34 > .wp-block-kadence-advancedbtn{margin-top:1em;}.kb-block-show-more-container95194_046f4b-34 > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(2), .kb-block-show-more-container95194_046f4b-34 > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(2){display:none;}.kb-block-show-more-container95194_046f4b-34 > .wp-block-kadence-column{max-height:145px;overflow-y:hidden;}.kb-block-show-more-container95194_046f4b-34.kb-smc-open > .wp-block-kadence-column{max-height:none;-webkit-mask-image:none;mask-image:none;overflow-y:unset;}.kb-block-show-more-container95194_046f4b-34.kb-smc-open > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(1), .kb-block-show-more-container95194_046f4b-34.kb-smc-open > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(1){display:none;}.kb-block-show-more-container95194_046f4b-34.kb-smc-open > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(2), .kb-block-show-more-container95194_046f4b-34.kb-smc-open > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(2){display:inline-flex;}.kb-block-show-more-container95194_046f4b-34.kb-smc-open > .wp-block-kadence-advancedbtn.kt-force-btn-fullwidth .kt-btn-wrap:nth-child(2){display:block;}<\/style>\n<div class=\"wp-block-kadence-show-more kb-block-show-more-container kb-block-show-more-container95194_046f4b-34\"><div class=\"kb-show-more-sr-excerpt\" aria-live=\"polite\" aria-atomic=\"true\"><\/div><style>.kadence-column95194_46d89e-a6 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_46d89e-a6 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_46d89e-a6 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_46d89e-a6 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_46d89e-a6{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_46d89e-a6 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_46d89e-a6 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_46d89e-a6 kb-show-more-content\"><div class=\"kt-inside-inner-col\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Poster<\/strong>: <\/strong><\/strong>Virtual Chromatographic Modeling Software for Optimizing Separation of Isobaric Compounds<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><br><strong>Presenter(s)\/Co-Author(s):<\/strong>\u00a0Colton Myers, Erika Pack, Chris English, Jennifer Lindner, Jessi Collier<sup>\u00a0<\/sup><br><strong><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GC_RMX_EPRW2026_EZGC-and-Pesticides-on-RMX_Druck.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Download<\/a><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>See this poster presented<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Poster Session 2: 10 June, 15:45 \u2013 17:00<\/li>\n\n\n\n<li>Poster Session 3: 11 June, 17:00 \u2013 18:00&nbsp;<br><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Per- and Polyfluoroalkyl Substances (PFAS) are&nbsp;synthetic organofluorine&nbsp;chemicals that have been linked to a&nbsp;range of&nbsp;health effects, including decrease immune&nbsp;response, vaccine&nbsp;effectiveness, cancer risk, among others.&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this work we show a comprehensive analysis of 40 target PFAS compounds<strong>&nbsp;<\/strong>in different aqueous, solids, and&nbsp;tissue matrixes. This method uses a weak anion&nbsp;exchange (WAX) solid phase extraction (SPE), coupled with&nbsp;a dispersive&nbsp;graphitized carbon black (GCB) clean-up&nbsp;step prior&nbsp;to LC-MS\/MS analysis on a C18 column.&nbsp;<\/p>\n<\/div><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_512ce5-1b{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns95194_512ce5-1b .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_512ce5-1b .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_512ce5-1b .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_512ce5-1b .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_512ce5-1b .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_512ce5-1b .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_512ce5-1b .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_512ce5-1b .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_512ce5-1b kb-show-more-buttons\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_0153e8-24.kb-button{width:initial;}<\/style><button class=\"kb-button kt-button button kb-btn95194_0153e8-24 kt-btn-size-small kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\"><span class=\"kt-btn-inner-text\">Show More<\/span><\/button>\n\n<style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_1da160-21.kb-button{width:initial;}<\/style><button class=\"kb-button kt-button button kb-btn95194_1da160-21 kt-btn-size-small kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\"><span class=\"kt-btn-inner-text\">Show Less<\/span><\/button><\/div>\n<\/div>\n\n\n\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-block-show-more-container95194_053e88-57 > .kb-show-more-sr-excerpt{position:absolute;width:1px;height:1px;margin:-1px;overflow:hidden;clip:rect(0, 0, 0, 0);white-space:nowrap;}.kb-block-show-more-container95194_053e88-57 > .wp-block-kadence-advancedbtn{margin-top:1em;}.kb-block-show-more-container95194_053e88-57 > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(2), .kb-block-show-more-container95194_053e88-57 > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(2){display:none;}.kb-block-show-more-container95194_053e88-57 > .wp-block-kadence-column{max-height:145px;overflow-y:hidden;}.kb-block-show-more-container95194_053e88-57.kb-smc-open > .wp-block-kadence-column{max-height:none;-webkit-mask-image:none;mask-image:none;overflow-y:unset;}.kb-block-show-more-container95194_053e88-57.kb-smc-open > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(1), .kb-block-show-more-container95194_053e88-57.kb-smc-open > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(1){display:none;}.kb-block-show-more-container95194_053e88-57.kb-smc-open > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(2), .kb-block-show-more-container95194_053e88-57.kb-smc-open > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(2){display:inline-flex;}.kb-block-show-more-container95194_053e88-57.kb-smc-open > .wp-block-kadence-advancedbtn.kt-force-btn-fullwidth .kt-btn-wrap:nth-child(2){display:block;}<\/style>\n<div class=\"wp-block-kadence-show-more kb-block-show-more-container kb-block-show-more-container95194_053e88-57\"><div class=\"kb-show-more-sr-excerpt\" aria-live=\"polite\" aria-atomic=\"true\"><\/div><style>.kadence-column95194_52c537-d7 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_52c537-d7 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_52c537-d7 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_52c537-d7 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_52c537-d7{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_52c537-d7 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_52c537-d7 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_52c537-d7 kb-show-more-content\"><div class=\"kt-inside-inner-col\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Poster<\/strong>: <\/strong><\/strong>Cutting Downtime, not Columns: Performance of a Next-Generation Inert Capillary Column for Multiresidue GC-MS\/MS Analysis<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><br><strong>Presenter(s)\/Co-Author(s):<\/strong>\u00a0Colton Myers, Jessi Collier, Jennifer Lindner, Jonathan\u00a0DeCenzi,\u00a0Rima Juskelis, Carlos Parra<br><strong><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/POSTER-_GC_RMX_EPRW2026_INERT_Multiresidue_MSMS-cmeRv1_KB_RJ-_0522_2026.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Download<\/a><\/strong><br><br><strong>See this poster presented<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Poster Session 1: 9 June, 17:00 \u2013 18:00&nbsp;<\/li>\n\n\n\n<li>Poster Session 3: 11 June, 17:00 \u2013 18:00&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A recent advancement in gas chromatography (GC) column deactivation balances chromatographic performance of acidic,&nbsp;basic&nbsp;and neutral analytes at trace level concentrations. Deactivation is a critical step in GC column manufacturing that&nbsp;modifies&nbsp;the fused silica capillary surface activity to promote coating and adhesion. Residual surface&nbsp;silanols, which result from incomplete deactivation or surface contamination, adsorb acidic and basic compounds resulting in peak area loss or tailing. <br><br>Deactivation procedures vary between products and manufacturers, with individual benefits and drawbacks that become exacerbated during sensitive applications. There is increasing demand to improve identification and quantification of reactive analytes with complex or&nbsp;consolidated&nbsp;methodologies. New GC deactivation technology improves polymer adhesion and minimizes residual surface activity for a long lasting, broadly inert surface. Columns built with the new GC deactivation technology were challenged with a wide variety of applications, and against traditional 5-type columns. <br><br>Overall, the new deactivation presents an advancement over traditional GC columns, providing unparalleled inertness to a broader range of acids, bases, and neutrals. These improvements offer opportunity for method consolidation and trace level analysis that would not be successful with traditional technology.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br><br><\/p>\n<\/div><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_1d956e-fe{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns95194_1d956e-fe .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_1d956e-fe .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_1d956e-fe .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_1d956e-fe .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_1d956e-fe .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_1d956e-fe .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_1d956e-fe .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_1d956e-fe .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_1d956e-fe kb-show-more-buttons\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_6a5aa7-06.kb-button{width:initial;}<\/style><button class=\"kb-button kt-button button kb-btn95194_6a5aa7-06 kt-btn-size-small kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\"><span class=\"kt-btn-inner-text\">Show More<\/span><\/button>\n\n<style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_277855-b5.kb-button{width:initial;}<\/style><button class=\"kb-button kt-button button kb-btn95194_277855-b5 kt-btn-size-small kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\"><span class=\"kt-btn-inner-text\">Show Less<\/span><\/button><\/div>\n<\/div>\n\n\n\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-block-show-more-container95194_fcabf5-4c > .kb-show-more-sr-excerpt{position:absolute;width:1px;height:1px;margin:-1px;overflow:hidden;clip:rect(0, 0, 0, 0);white-space:nowrap;}.kb-block-show-more-container95194_fcabf5-4c > .wp-block-kadence-advancedbtn{margin-top:1em;}.kb-block-show-more-container95194_fcabf5-4c > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(2), .kb-block-show-more-container95194_fcabf5-4c > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(2){display:none;}.kb-block-show-more-container95194_fcabf5-4c > .wp-block-kadence-column{max-height:145px;overflow-y:hidden;}.kb-block-show-more-container95194_fcabf5-4c.kb-smc-open > .wp-block-kadence-column{max-height:none;-webkit-mask-image:none;mask-image:none;overflow-y:unset;}.kb-block-show-more-container95194_fcabf5-4c.kb-smc-open > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(1), .kb-block-show-more-container95194_fcabf5-4c.kb-smc-open > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(1){display:none;}.kb-block-show-more-container95194_fcabf5-4c.kb-smc-open > .wp-block-kadence-advancedbtn .kt-btn-wrap:nth-child(2), .kb-block-show-more-container95194_fcabf5-4c.kb-smc-open > .wp-block-kadence-advancedbtn .wp-block-kadence-singlebtn:nth-of-type(2){display:inline-flex;}.kb-block-show-more-container95194_fcabf5-4c.kb-smc-open > .wp-block-kadence-advancedbtn.kt-force-btn-fullwidth .kt-btn-wrap:nth-child(2){display:block;}<\/style>\n<div class=\"wp-block-kadence-show-more kb-block-show-more-container kb-block-show-more-container95194_fcabf5-4c\"><div class=\"kb-show-more-sr-excerpt\" aria-live=\"polite\" aria-atomic=\"true\"><\/div><style>.kadence-column95194_f94af4-d1 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_f94af4-d1 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_f94af4-d1 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_f94af4-d1 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_f94af4-d1{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_f94af4-d1 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_f94af4-d1 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_f94af4-d1 kb-show-more-content\"><div class=\"kt-inside-inner-col\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong><strong><strong>Poster<\/strong>: <\/strong><\/strong>Improved Baseline Stability And Sensitivity In GC\u2013MS Using A Novel Column With A Unique Interface Section<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\"><br><strong>Presenter(s)\/Co-Author(s):<\/strong>\u00a0Javier Arrebola , Colton Myers , Ramkumar Dhandapani, Jaap de Zeeuw<br><strong><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/EPRW-Baseline-RMX.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Download<\/a><\/strong><br><br><strong>See this poster presented<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Poster Session 1: 9 June, 17:00 \u2013 18:00&nbsp;<\/li>\n\n\n\n<li>Poster Session 3: 11 June, 17:00 \u2013 18:00&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A novel gas chromatography\u2013mass spectrometry (GC\u2013MS) column design has been developed to enhance analytical performance by addressing persistent challenges in baseline stability and sensitivity. This innovation integrates a unique interface configuration that minimizes stationary phase degradation and thermal stress effects, particularly under elevated transfer line temperatures. Comparative evaluations using a diverse panel of pesticide analytes demonstrated significantly faster baseline stabilization and reduced background noise relative to conventional columns.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br>The new column architecture consistently delivered improved signal-to-noise ratios across full-scan and SIM modes, with pronounced benefits observed for high-boiling-point and late-eluting compounds. These enhancements suggest a substantial reduction in analyte loss and column bleed, enabling more reliable detection of thermally labile substances. The findings underscore the potential of this design to advance GC\u2013MS methodologies in trace-level contaminant analysis and complex sample matrices.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br><br><\/p>\n<\/div><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_d7f98b-78{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns95194_d7f98b-78 .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_d7f98b-78 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_d7f98b-78 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_d7f98b-78 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_d7f98b-78 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_d7f98b-78 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_d7f98b-78 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_d7f98b-78 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_d7f98b-78 kb-show-more-buttons\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_5daa70-19.kb-button{width:initial;}<\/style><button class=\"kb-button kt-button button kb-btn95194_5daa70-19 kt-btn-size-small kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\"><span class=\"kt-btn-inner-text\">Show More<\/span><\/button>\n\n<style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_82c117-53.kb-button{width:initial;}<\/style><button class=\"kb-button kt-button button kb-btn95194_82c117-53 kt-btn-size-small kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\"><span class=\"kt-btn-inner-text\">Show Less<\/span><\/button><\/div>\n<\/div>\n\n\n\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-theme-palette-1-color has-text-color has-link-color has-large-font-size wp-elements-fe8006ec695261f114f2c0a15723cdce\" id=\"ProductsSolutions\"><strong>Featured Products &amp; Analytical Solutions<br><\/strong><\/h2>\n\n\n<style>.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap{column-gap:var(--global-kb-gap-sm, 1rem);row-gap:var(--global-kb-gap-sm, 1rem);padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);}.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap{grid-template-columns:repeat(3, minmax(0, 1fr));}.kb-row-layout-id95194_8eb6ce-8a > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}}@media all and (max-width: 1024px){.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap{grid-template-columns:repeat(3, minmax(0, 1fr));}}@media all and (max-width: 767px){.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}.kb-row-layout-id95194_8eb6ce-8a > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id95194_8eb6ce-8a alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-3-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column95194_61392f-42 > .kt-inside-inner-col,.kadence-column95194_61392f-42 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_61392f-42 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_61392f-42 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_61392f-42 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_61392f-42 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_61392f-42{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_61392f-42 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_61392f-42 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_61392f-42\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/fr.restek.com\/ccstore\/v1\/images\/?source=\/file\/v694075117029651123\/products\/rmx_column_with_box.jpg&amp;height=475&amp;width=475&amp;quality=0.8&amp;outputFormat=JPEG\" alt=\"\" style=\"width:200px\" title=\"-\"><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_fb48b2-19{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns95194_fb48b2-19 .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_fb48b2-19 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_fb48b2-19 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_fb48b2-19 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_fb48b2-19 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_fb48b2-19 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_fb48b2-19 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_fb48b2-19 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_fb48b2-19\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_14218e-8a.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_14218e-8a kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/c\/rmx?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>New RMX Columns<\/strong><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column95194_3e5459-c2 > .kt-inside-inner-col,.kadence-column95194_3e5459-c2 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_3e5459-c2 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_3e5459-c2 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_3e5459-c2 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_3e5459-c2 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_3e5459-c2{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_3e5459-c2 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_3e5459-c2 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_3e5459-c2\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"234\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/EZGC_analytica-1.png\" alt=\"\" class=\"wp-image-88134\" style=\"aspect-ratio:1.101178697410307;object-fit:contain;width:200px\" title=\"-\"><\/figure>\n<\/div>\n\n\n<div style=\"height:16px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_cd3b32-dc{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns95194_cd3b32-dc .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_cd3b32-dc .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_cd3b32-dc .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_cd3b32-dc .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_cd3b32-dc .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_cd3b32-dc .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_cd3b32-dc .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_cd3b32-dc .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_cd3b32-dc\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_ff9d76-82.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_ff9d76-82 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/articles\/gnot3445\/ezgc-online-tools\"><span class=\"kt-btn-inner-text\"><strong><em>EZ<\/em>GC Online Suite<\/strong><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column95194_227ecf-f9 > .kt-inside-inner-col,.kadence-column95194_227ecf-f9 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_227ecf-f9 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_227ecf-f9 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_227ecf-f9 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_227ecf-f9 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_227ecf-f9{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_227ecf-f9 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_227ecf-f9 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_227ecf-f9\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\" style=\"margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40)\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"234\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/EZLC_analytica.png\" alt=\"\" class=\"wp-image-88140\" style=\"width:200px\" title=\"-\"><\/figure>\n<\/div>\n\n\n<div style=\"height:7px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_47239b-0f{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns95194_47239b-0f .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_47239b-0f .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_47239b-0f .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_47239b-0f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_47239b-0f .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_47239b-0f .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_47239b-0f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_47239b-0f .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_47239b-0f\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_ba0eb3-de.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_ba0eb3-de kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/articles-zh\/gnot3446\/pro-ezlc-online-tools\"><span class=\"kt-btn-inner-text\"><strong><em>EZ<\/em>LC Online Suite<\/strong><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div>\n\n<style>.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap{column-gap:var(--global-kb-gap-sm, 1rem);row-gap:var(--global-kb-gap-sm, 1rem);padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);}.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap{grid-template-columns:repeat(3, minmax(0, 1fr));}.kb-row-layout-id95194_5a467e-f9 > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}}@media all and (max-width: 1024px){.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap{grid-template-columns:repeat(3, minmax(0, 1fr));}}@media all and (max-width: 767px){.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}.kb-row-layout-id95194_5a467e-f9 > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id95194_5a467e-f9 alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-3-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column95194_c3f0e3-b4 > .kt-inside-inner-col,.kadence-column95194_c3f0e3-b4 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_c3f0e3-b4 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_c3f0e3-b4 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_c3f0e3-b4 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_c3f0e3-b4 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_c3f0e3-b4{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_c3f0e3-b4 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_c3f0e3-b4 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_c3f0e3-b4\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"363\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc.png\" alt=\"\" class=\"wp-image-29758\" style=\"width:200px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc.png 400w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-300x272.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_c956cb-85{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns95194_c956cb-85 .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_c956cb-85 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_c956cb-85 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_c956cb-85 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_c956cb-85 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_c956cb-85 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_c956cb-85 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_c956cb-85 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_c956cb-85\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_b729a0-5b.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_b729a0-5b kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/fr.restek.com\/c\/1275?Ns=bestMatch&#038;NttWithIn=inertehttps:\/\/www.restek.com\/search?Ntt=inert+lc+column&#038;Ns=bestMatch\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Inert LC<\/strong> <strong>Columns<\/strong><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column95194_d9b6a3-15 > .kt-inside-inner-col,.kadence-column95194_d9b6a3-15 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_d9b6a3-15 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_d9b6a3-15 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_d9b6a3-15 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_d9b6a3-15 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_d9b6a3-15{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_d9b6a3-15 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_d9b6a3-15 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_d9b6a3-15\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\" style=\"margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40)\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"234\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/raptor_analytica.png\" alt=\"\" class=\"wp-image-88158\" style=\"width:200px\" title=\"-\"><\/figure>\n<\/div>\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_b497d3-9c{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns95194_b497d3-9c .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_b497d3-9c .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_b497d3-9c .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_b497d3-9c .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_b497d3-9c .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_b497d3-9c .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_b497d3-9c .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_b497d3-9c .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_b497d3-9c\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_e607c6-29.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_e607c6-29 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/fr.restek.com\/search?Ntt=Polar+X&#038;Ns=bestMatch\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Raptor Polar X Columns<\/strong><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column95194_5cda6f-db > .kt-inside-inner-col,.kadence-column95194_5cda6f-db > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_5cda6f-db > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_5cda6f-db > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_5cda6f-db > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_5cda6f-db > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_5cda6f-db{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_5cda6f-db > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_5cda6f-db > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_5cda6f-db\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"600\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Multiresidue-Pesticide-Standards-Kits-1.png\" alt=\"\" class=\"wp-image-95297\" style=\"width:200px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Multiresidue-Pesticide-Standards-Kits-1.png 750w, https:\/\/discover.restek.com\/wp-content\/uploads\/Multiresidue-Pesticide-Standards-Kits-1-300x240.png 300w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_d2b8c5-c5{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns95194_d2b8c5-c5 .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_d2b8c5-c5 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_d2b8c5-c5 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_d2b8c5-c5 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_d2b8c5-c5 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_d2b8c5-c5 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_d2b8c5-c5 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_d2b8c5-c5 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_d2b8c5-c5\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_153167-e3.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_153167-e3 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/search?Ntt=Multiresidue+Pesticide+Standards+Kit&#038;Ns=bestMatch\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>GC &amp; LC Multiresidue Pesticide Kits<\/strong><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div>\n\n<style>.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap{column-gap:var(--global-kb-gap-sm, 1rem);row-gap:var(--global-kb-gap-sm, 1rem);padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);}.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap{grid-template-columns:repeat(3, minmax(0, 1fr));}.kb-row-layout-id95194_e4bd8f-92 > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}}@media all and (max-width: 1024px){.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap{grid-template-columns:repeat(3, minmax(0, 1fr));}}@media all and (max-width: 767px){.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap > div:not(.added-for-specificity){grid-column:initial;}.kb-row-layout-id95194_e4bd8f-92 > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id95194_e4bd8f-92 alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-3-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column95194_213005-43 > .kt-inside-inner-col,.kadence-column95194_213005-43 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_213005-43 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_213005-43 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_213005-43 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_213005-43 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_213005-43{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_213005-43 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_213005-43 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_213005-43\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"750\" height=\"600\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RS-Finder-1.png\" alt=\"\" class=\"wp-image-95296\" style=\"width:200px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RS-Finder-1.png 750w, https:\/\/discover.restek.com\/wp-content\/uploads\/RS-Finder-1-300x240.png 300w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:29px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_0ce897-1c{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns95194_0ce897-1c .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_0ce897-1c .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_0ce897-1c .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_0ce897-1c .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_0ce897-1c .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_0ce897-1c .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_0ce897-1c .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_0ce897-1c .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_0ce897-1c\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_adaa74-79.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_adaa74-79 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/tools.restek.com\/\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Restek Reference Standard Finder tool<\/strong><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column95194_dfa882-a4 > .kt-inside-inner-col,.kadence-column95194_dfa882-a4 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column95194_dfa882-a4 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column95194_dfa882-a4 > .kt-inside-inner-col{flex-direction:column;}.kadence-column95194_dfa882-a4 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column95194_dfa882-a4 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column95194_dfa882-a4{position:relative;}@media all and (max-width: 1024px){.kadence-column95194_dfa882-a4 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column95194_dfa882-a4 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column95194_dfa882-a4\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"234\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/PFAS_analytica.png\" alt=\"\" class=\"wp-image-88556\" style=\"width:200px\" title=\"-\"><\/figure>\n<\/div>\n\n\n<div style=\"height:27px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns95194_111d5b-13{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns95194_111d5b-13 .kt-button{font-weight:normal;font-style:normal;}.kt-btns95194_111d5b-13 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns95194_111d5b-13 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns95194_111d5b-13 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_111d5b-13 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns95194_111d5b-13 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns95194_111d5b-13 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns95194_111d5b-13 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns95194_111d5b-13\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn95194_769b72-9f.kb-button{width:initial;}<\/style><a class=\"kb-button kt-button button kb-btn95194_769b72-9f kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/search?Ntt=PFAS+SPE&#038;Ns=bestMatch\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Resprep Dual-Bed PFAS Cartridges<\/strong><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n\n<\/div><\/div>\n\n\n<div style=\"height:41px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><strong><a href=\"https:\/\/discover.restek.com\/rmx\/\"><strong>Unleash your performance with RMX GC Columns<\/strong>\u2192<\/a><\/strong><br>By maximizing data quality, RMX GC columns generate more compliant results\u2014even for the most challenging\u202fsemivolatiles\u2014so\u202faccurate\u202fresults are reported, and samples keep moving through the lab. Ask us about the future of GC!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><strong><a href=\"https:\/\/ez.restek.com\/\" target=\"_blank\" rel=\"noopener\"><strong><em>EZ<\/em> \u202fsuite: refine methods online for free in real time.<\/strong>\u2192<\/a><\/strong><br>Optimize\u202for amend your GC and LC methods in minutes from your desk. Our online software and calculators are reliable, easy to\u202fuse\u202fand\u202fallow you\u202fto perform method development without guesswork. Stop by for a demo!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><a href=\"https:\/\/discover.restek.com\/pfas-analysis\/\"><strong>PFAS Problems?&nbsp;We\u2019re&nbsp;Here to Help.\u2192<\/strong><\/a><br>The landscape of PFAS testing regulations and methods continues to evolve around the world, yet the needs of analytical labs are universal. You need fast,&nbsp;accurate, and dependable products supported by personalized advice and expert technical service from people who understand the challenges of these demanding analyses.&nbsp;That\u2019s&nbsp;where Restek&nbsp;come&nbsp;in!&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><a href=\"https:\/\/discover.restek.com\/articles\/gnss4155\/accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns\" data-type=\"post\" data-id=\"45251\"><strong>Perform improved analysis of metal-sensitive compounds with Inert LC columns.<\/strong><\/a><strong>\u2192<\/strong><br>Inert LC column technology reduces nonspecific binding of chelating analytes, enabling sensitive analysis and smooth integration of peaks. Talk to our Restek team about how it could support your LC.\u202f&nbsp;<\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<style>\n  \/*WordPress Customization*\/\n\n\n\n  .single-post .author-down {\n    display: none;\n}\n\n.single-post ul.wp-block-list {\n    margin-bottom: 0px;\n}\n\n.cat-name {\n    display: none;\n    margin-top: 0px !important;\n}\n  \n  .single-post p.cat-name {\n    display: none;\n}\n\n  .single-post p.date {\n    display: none;\n}\n\nnav.breadcrumbs {\n    display:none;\n}\n\n.author-details-info {\n  display: none;\n}\n\n\n<\/style>\n","protected":false},"excerpt":{"rendered":"<p>Come and meet us at the&nbsp;Postillion Hotel &amp; Convention Centre at booth 15!&nbsp; We\u2019re&nbsp;off to Rotterdam for&nbsp;the&nbsp;16th&nbsp;European Pesticide Residue Workshop,&nbsp;the&nbsp;key event dedicated to the latest developments in pesticide residue analysis in food,&nbsp;monitoring&nbsp;and control.&nbsp;Drop by booth 15 to:&nbsp; Technical Presentations Featured Products &amp; Analytical Solutions Unleash your performance with RMX GC Columns\u2192By maximizing data quality, RMX&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[799],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814],"class_list":["post-95194","post","type-post","status-publish","format-standard","hentry","category-events-ja"],"acf":[],"taxonomy_info":{"category":[{"value":799,"label":"\u30a4\u30d9\u30f3\u30c8\u60c5\u5831"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":799,"name":"\u30a4\u30d9\u30f3\u30c8\u60c5\u5831","slug":"events-ja","term_group":0,"term_taxonomy_id":799,"taxonomy":"category","description":"","parent":0,"count":15,"filter":"raw","cat_ID":799,"category_count":15,"category_description":"","cat_name":"\u30a4\u30d9\u30f3\u30c8\u60c5\u5831","category_nicename":"events-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=95194"}],"version-history":[{"count":25,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95194\/revisions"}],"predecessor-version":[{"id":100925,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95194\/revisions\/100925"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=95194"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=95194"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=95194"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=95194"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=95194"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=95194"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=95194"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=95194"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=95194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}