{"id":95610,"date":"2025-08-01T16:33:15","date_gmt":"2025-08-01T16:33:15","guid":{"rendered":"https:\/\/discover.restek.com\/?p=95610"},"modified":"2026-06-08T04:04:21","modified_gmt":"2026-06-08T04:04:21","slug":"how-do-i-know-if-my-lc-system-has-pfas-contamination","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5094-ja\/how-do-i-know-if-my-lc-system-has-pfas-contamination","title":{"rendered":"LC\u30b7\u30b9\u30c6\u30e0\u306bPFAS\u6c5a\u67d3\u304c\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3059\u308b\u65b9\u6cd5\u3092\u6559\u3048\u3066\u4e0b\u3055\u3044"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">LC\u30b7\u30b9\u30c6\u30e0\u306bPFAS\u6c5a\u67d3\u304c\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3059\u308b\u6700\u3082\u7c21\u5358\u306a\u65b9\u6cd5\u306f\u4ee5\u4e0b\u306e\u3068\u304a\u308a\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001\u79fb\u52d5\u76f8\u3092\u30ab\u30e9\u30e0\u306b30\u5206\u9593\u9001\u6db2\u3057\u3066\u30b7\u30b9\u30c6\u30e0\u3092\u5e73\u8861\u5316\u3057\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u3092\u5206\u6790\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u307e\u305f\u306f\u5148\u7aef\u90e8\u306b\u84c4\u7a4d\u3055\u305b\u307e\u3059\u3002\u7d9a\u3044\u3066\u30d6\u30e9\u30f3\u30af\u6eb6\u6db2\u3092\u6ce8\u5165\u3057\u3066\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6eb6\u51fa\u3092\u884c\u3046\u3068\u3001\u30ab\u30e9\u30e0\u306b\u84c4\u7a4d\u3057\u305fPFAS\u304c\u6eb6\u51fa\u3057\u3001\u8a66\u6599\u4e2d\u306ePFAS\u4fdd\u6301\u6642\u9593\u3068\u540c\u4f4d\u7f6e\u306b\u73fe\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001\u5e73\u8861\u5316\u5f8c\u306e1\u56de\u76ee\u306e\u30d6\u30e9\u30f3\u30af\u6ce8\u5165\u304c\u7d42\u308f\u3063\u305f\u3089\u3001\u30ab\u30e9\u30e0\u306e\u518d\u5e73\u8861\u5316\u3092\u884c\u308f\u305a\u305f\u3060\u3061\u306b2\u56de\u76ee\u306e\u30d6\u30e9\u30f3\u30af\u6ce8\u5165\u3092\u884c\u3044\u3001PFAS\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u3092\u78ba\u8a8d\u3057\u307e\u3059\u30022\u56de\u76ee\u306e\u6ce8\u5165\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u304c\u30ab\u30e9\u30e0\u306b\u84c4\u7a4d\u3059\u308b\u524d\u306b\u884c\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u5e72\u6e09\u304c\u306a\u3044\u72b6\u614b\u3067\u306e\u30d6\u30e9\u30f3\u30af\u4fdd\u6301\u6642\u9593\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2\u56de\u306e\u6ce8\u5165\u7d50\u679c\u3092\u6bd4\u8f03\u3059\u308b\uff1a<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>1\u56de\u76ee\uff08\u9577\u6642\u9593\u5e73\u8861\u5316\u5f8c\uff09\u306e\u307fPFAS\u304c\u691c\u51fa\u3055\u308c\u30012\u56de\u76ee\u3067\u306f\u691c\u51fa\u3055\u308c\u306a\u3044\u5834\u5408<\/strong>\uff1a \u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u304c\u6eb6\u51fa\u3057\u3066\u304a\u308a\u3001\u6975\u4f4e\u6fc3\u5ea6\u5206\u6790\u3078\u306e\u5e72\u6e09\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u4e21\u65b9\u306e\u6ce8\u5165\u3067PFAS\u304c\u691c\u51fa\u3055\u308c\u306a\u3044\u5834\u5408<\/strong>\uff1a \u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u5e72\u6e09\u306f\u5927\u304d\u304f\u306a\u3044\u3068\u5224\u65ad\u3067\u304d\u307e\u3059\u3002\u9577\u671f\u9593\u4f7f\u7528\u3057\u3066\u3044\u308bLC\u30e6\u30cb\u30c3\u30c8\u306b\u65b0\u3057\u3044\u8cea\u91cf\u5206\u6790\u8a08\u3092\u7d44\u307f\u5408\u308f\u305b\u3066\u3044\u308b\u5834\u5408\u306a\u3069\u3067\u898b\u3089\u308c\u307e\u3059\u3002\u4f7f\u7528\u671f\u9593\u304c\u9577\u3044\u307b\u3069\u3001\u6eb6\u51fa\u3057\u3084\u3059\u3044\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u306f\u3059\u3067\u306b\u6eb6\u51fa\u3057\u304d\u3063\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3060\u3057\u3001\u3053\u306e\u72b6\u614b\u306f\u6052\u4e45\u7684\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u30fc\u3088\u308a\u4e0a\u6d41\u306e\u30b7\u30b9\u30c6\u30e0\u5185\u306e\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u90e8\u54c1\u3092\u4ea4\u63db\u3059\u308b\u969b\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002PFAS\u5bfe\u5fdc\uff08PFAS\u4e0d\u6eb6\u51fa\uff09\u90e8\u54c1\u3092\u4f7f\u7528\u3057\u306a\u3044\u9650\u308a\u3001\u4ea4\u63db\u90e8\u54c1\u304b\u3089PFAS\u304c\u518d\u5ea6\u6eb6\u51fa\u3059\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>LC\u30b7\u30b9\u30c6\u30e0\u306bPFAS\u6c5a\u67d3\u304c\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3059\u308b\u6700\u3082\u7c21\u5358\u306a\u65b9\u6cd5\u306f\u4ee5\u4e0b\u306e\u3068\u304a\u308a\u3067\u3059\u3002 \u307e\u305a\u3001\u79fb\u52d5\u76f8\u3092\u30ab\u30e9\u30e0\u306b30\u5206\u9593\u9001\u6db2\u3057\u3066\u30b7\u30b9\u30c6\u30e0\u3092\u5e73\u8861\u5316\u3057\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u3092\u5206\u6790\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u307e\u305f\u306f\u5148\u7aef\u90e8\u306b\u84c4\u7a4d\u3055\u305b\u307e\u3059\u3002\u7d9a\u3044\u3066\u30d6\u30e9\u30f3\u30af\u6eb6\u6db2\u3092\u6ce8\u5165\u3057\u3066\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6eb6\u51fa\u3092\u884c\u3046\u3068\u3001\u30ab\u30e9\u30e0\u306b\u84c4\u7a4d\u3057\u305fPFAS\u304c\u6eb6\u51fa\u3057\u3001\u8a66\u6599\u4e2d\u306ePFAS\u4fdd\u6301\u6642\u9593\u3068\u540c\u4f4d\u7f6e\u306b\u73fe\u308c\u307e\u3059\u3002 \u6b21\u306b\u3001\u5e73\u8861\u5316\u5f8c\u306e1\u56de\u76ee\u306e\u30d6\u30e9\u30f3\u30af\u6ce8\u5165\u304c\u7d42\u308f\u3063\u305f\u3089\u3001\u30ab\u30e9\u30e0\u306e\u518d\u5e73\u8861\u5316\u3092\u884c\u308f\u305a\u305f\u3060\u3061\u306b2\u56de\u76ee\u306e\u30d6\u30e9\u30f3\u30af\u6ce8\u5165\u3092\u884c\u3044\u3001PFAS\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u3092\u78ba\u8a8d\u3057\u307e\u3059\u30022\u56de\u76ee\u306e\u6ce8\u5165\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u304c\u30ab\u30e9\u30e0\u306b\u84c4\u7a4d\u3059\u308b\u524d\u306b\u884c\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u5e72\u6e09\u304c\u306a\u3044\u72b6\u614b\u3067\u306e\u30d6\u30e9\u30f3\u30af\u4fdd\u6301\u6642\u9593\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002 2\u56de\u306e\u6ce8\u5165\u7d50\u679c\u3092\u6bd4\u8f03\u3059\u308b\uff1a \u305f\u3060\u3057\u3001\u3053\u306e\u72b6\u614b\u306f\u6052\u4e45\u7684\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u30fc\u3088\u308a\u4e0a\u6d41\u306e\u30b7\u30b9\u30c6\u30e0\u5185\u306e\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u90e8\u54c1\u3092\u4ea4\u63db\u3059\u308b\u969b\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002PFAS\u5bfe\u5fdc\uff08PFAS\u4e0d\u6eb6\u51fa\uff09\u90e8\u54c1\u3092\u4f7f\u7528\u3057\u306a\u3044\u9650\u308a\u3001\u4ea4\u63db\u90e8\u54c1\u304b\u3089PFAS\u304c\u518d\u5ea6\u6eb6\u51fa\u3059\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[],"industries-application":[2288],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814],"class_list":["post-95610","post","type-post","status-publish","format-standard","hentry","category-faq-ja","industries-application-pfas-testing-ja"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=95610"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95610\/revisions"}],"predecessor-version":[{"id":96785,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95610\/revisions\/96785"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=95610"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=95610"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=95610"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=95610"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=95610"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=95610"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=95610"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=95610"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=95610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}