{"id":95617,"date":"2021-01-13T00:00:00","date_gmt":"2021-01-13T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=95617"},"modified":"2026-06-08T02:24:15","modified_gmt":"2026-06-08T02:24:15","slug":"simple-large-volume-injection-method-for-trace-level-glyphosate-in-bottled-drinking-water","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evfa3196-ja\/simple-large-volume-injection-method-for-trace-level-glyphosate-in-bottled-drinking-water","title":{"rendered":"\u5927\u5bb9\u91cf\u6ce8\u5165\u6cd5\u306b\u3088\u308b\u30dc\u30c8\u30eb\u5165\u308a\u98f2\u6599\u6c34\u4e2d\u306e\u30b7\u30f3\u30d7\u30eb\u306a\u5fae\u91cf\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u5206\u6790"},"content":{"rendered":"\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u8a98\u5c0e\u4f53\u5316\u3084\u30a4\u30aa\u30f3\u30da\u30a2\u8a66\u85ac\u306e\u6dfb\u52a0\u3092\u305b\u305a\u306b\u3001\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u3092\u5206\u6790\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>Raptor Polar X\u30ab\u30e9\u30e0\u306e\u72ec\u81ea\u56fa\u5b9a\u76f8\u304c\u826f\u597d\u306a\u4fdd\u6301\u3068\u52b9\u7387\u7684\u306a\u6eb6\u51fa\u3092\u5b9f\u73fe\u3059\u308b\u3053\u3068\u3067\u3001\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u5927\u5bb9\u91cf\u30c0\u30a4\u30ec\u30af\u30c8\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3088\u308a\u3001ppt\u30ec\u30d9\u30eb\u306e\u691c\u51fa\u611f\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30dc\u30c8\u30eb\u5165\u308a\u98f2\u6599\u6c34\u4e2d\u306e\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u5206\u6790\u306b\u304a\u3051\u308b\u8ab2\u984c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u4e2d\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u306e\u5206\u6790\u306b\u306f\u4e3b\u306b\u4e8c\u3064\u306e\u6280\u8853\u7684\u8ab2\u984c\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4e00\u3064\u306f\u9006\u76f8\u30ab\u30e9\u30e0\u3078\u306e\u4fdd\u6301\u304c\u5f97\u3089\u308c\u306a\u3044\u3053\u3068\u3001\u3082\u3046\u4e00\u3064\u306fLC-MS\/MS\u30b7\u30b9\u30c6\u30e0\u306e\u30b5\u30f3\u30d7\u30eb\u6d41\u8def\u4e0a\u306e\u91d1\u5c5e\u8868\u9762\u3067\u30ad\u30ec\u30fc\u30c8\u304c\u5f62\u6210\u3055\u308c\u3001\u691c\u51fa\u611f\u5ea6\u304c\u4f4e\u4e0b\u3057\u3084\u3059\u3044\u3053\u3068\u3067\u3059\u3002<br>\u6027\u80fd\u3092\u88dc\u3046\u305f\u3081\u306b\u8a98\u5c0e\u4f53\u5316\u3084\u30a4\u30aa\u30f3\u30da\u30a2\u8a66\u85ac\u304c\u3057\u3070\u3057\u3070\u63a1\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u88c5\u7f6e\u3078\u306e\u8ca0\u62c5\u304c\u5927\u304d\u304f\u3001\u8a66\u6599\u8abf\u88fd\u306e\u5de5\u6570\u3082\u5897\u3048\u307e\u3059\u3002<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/9311A32\" target=\"_blank\" rel=\"noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u306f\u3053\u308c\u3089\u306e\u554f\u984c\u3092\u89e3\u6c7a\u3059\u308b\u3088\u308a\u826f\u3044\u9078\u629e\u80a2\u3067\u3059\u3002\u672c\u30ab\u30e9\u30e0\u306e\u72ec\u81ea\u56fa\u5b9a\u76f8\u306f\u3001\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u306e\u3088\u3046\u306a\u6975\u6027\u30a2\u30cb\u30aa\u30f3\u5316\u5408\u7269\u306b\u9ad8\u3044\u89aa\u548c\u6027\u3092\u793a\u3057\u3001\u52b9\u679c\u7684\u306a\u4fdd\u6301\u3068\u52b9\u7387\u7684\u306a\u6eb6\u51fa\u3092\u4e21\u7acb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Raptor Polar X\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5927\u5bb9\u91cf\u6ce8\u5165\u6cd5\u306b\u3088\u308b\u9ad8\u611f\u5ea6\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u30ab\u30e9\u30e0\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u30e1\u30ab\u30cb\u30ba\u30e0\u306b\u3088\u308a\u521d\u671f\u79fb\u52d5\u76f8\u6761\u4ef6\u4e0b\u3067<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/32426\" target=\"_blank\" rel=\"noopener\">\u30b0\u30ea\u30db\u30b5\u30fc\u30c8<\/a>\u304c\u5341\u5206\u306b\u4fdd\u6301\u3055\u308c\u308b\u305f\u3081\u3001\u30dc\u30c8\u30eb\u5165\u308a\u98f2\u6599\u6c34\u3092500 \u00b5L\u306e\u5927\u5bb9\u91cf\u3067\u76f4\u63a5\u6ce8\u5165\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u4f4e\u6fc3\u5ea6\u57df\u306e\u611f\u5ea6\u3092\u7c21\u4fbf\u306b\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4fdd\u6301\u30fb\u6eb6\u51fa\u7279\u6027\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u3001\u79fb\u52d5\u76f8\u6dfb\u52a0\u5264\u3068pH\u3092\u7cbe\u67fb\u3057\u3001\u9069\u5207\u306a\u4fdd\u6301\u304a\u3088\u3073\u826f\u597d\u306a\u611f\u5ea6\u3092\u4e0e\u3048\u308b\u8377\u96fb\u72b6\u614b\u306b\u8abf\u6574\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001LC\u30b7\u30b9\u30c6\u30e0\u3078\u306e\u4e00\u5ea6\u9650\u308a\u306e\u4e0d\u52d5\u614b\u5316\uff08\u30d1\u30c3\u30b7\u30d9\u30fc\u30b7\u30e7\u30f3\uff09\u51e6\u7406\uff08\u5206\u6790\u30ab\u30e9\u30e0\u304a\u3088\u3073\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u5916\u3057\u305f\u72b6\u614b\u3067\u5b9f\u65bd\uff09\u306b\u3088\u308a\u4e0d\u8981\u306a\u30ad\u30ec\u30fc\u30c8\u5f62\u6210\u3092\u6291\u5236\u3057\u305f\u3068\u3053\u308d\u3001100 ppt\uff08SN\u6bd4 > 50\uff09\u3067\u826f\u597d\u306a\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Raptor Polar X\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305fLC-MS\/MS\u5927\u5bb9\u91cf\u6ce8\u5165\u6cd5\u306b\u3088\u308b\u30dc\u30c8\u30eb\u5165\u308a\u98f2\u6599\u6c34\u4e2d\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u5206\u6790\uff08100 ppt\uff09\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u304a\u3088\u3073\u5206\u6790\u6761\u4ef6\u306fPDF\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3067\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0571.png\" alt=\"Glyphosate in Bottled Drinking Water at 100 ppt on Raptor Polar X by Large Volume Injection Using LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0571<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32426<\/li><li>9311A32<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>drinking<\/li><li>glyphosate<\/li><li>injection<\/li><li>large<\/li><li>volume<\/li><li>water<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0571.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30dc\u30c8\u30eb\u5165\u308a\u98f2\u6599\u6c34\u4e2d\u306e\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u5206\u6790\u306b\u304a\u3051\u308b\u8ab2\u984c \u6c34\u4e2d\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u306e\u5206\u6790\u306b\u306f\u4e3b\u306b\u4e8c\u3064\u306e\u6280\u8853\u7684\u8ab2\u984c\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4e00\u3064\u306f\u9006\u76f8\u30ab\u30e9\u30e0\u3078\u306e\u4fdd\u6301\u304c\u5f97\u3089\u308c\u306a\u3044\u3053\u3068\u3001\u3082\u3046\u4e00\u3064\u306fLC-MS\/MS\u30b7\u30b9\u30c6\u30e0\u306e\u30b5\u30f3\u30d7\u30eb\u6d41\u8def\u4e0a\u306e\u91d1\u5c5e\u8868\u9762\u3067\u30ad\u30ec\u30fc\u30c8\u304c\u5f62\u6210\u3055\u308c\u3001\u691c\u51fa\u611f\u5ea6\u304c\u4f4e\u4e0b\u3057\u3084\u3059\u3044\u3053\u3068\u3067\u3059\u3002\u6027\u80fd\u3092\u88dc\u3046\u305f\u3081\u306b\u8a98\u5c0e\u4f53\u5316\u3084\u30a4\u30aa\u30f3\u30da\u30a2\u8a66\u85ac\u304c\u3057\u3070\u3057\u3070\u63a1\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u88c5\u7f6e\u3078\u306e\u8ca0\u62c5\u304c\u5927\u304d\u304f\u3001\u8a66\u6599\u8abf\u88fd\u306e\u5de5\u6570\u3082\u5897\u3048\u307e\u3059\u3002Raptor Polar X\u30ab\u30e9\u30e0\u306f\u3053\u308c\u3089\u306e\u554f\u984c\u3092\u89e3\u6c7a\u3059\u308b\u3088\u308a\u826f\u3044\u9078\u629e\u80a2\u3067\u3059\u3002\u672c\u30ab\u30e9\u30e0\u306e\u72ec\u81ea\u56fa\u5b9a\u76f8\u306f\u3001\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u306e\u3088\u3046\u306a\u6975\u6027\u30a2\u30cb\u30aa\u30f3\u5316\u5408\u7269\u306b\u9ad8\u3044\u89aa\u548c\u6027\u3092\u793a\u3057\u3001\u52b9\u679c\u7684\u306a\u4fdd\u6301\u3068\u52b9\u7387\u7684\u306a\u6eb6\u51fa\u3092\u4e21\u7acb\u3057\u307e\u3059\u3002 Raptor Polar X\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5927\u5bb9\u91cf\u6ce8\u5165\u6cd5\u306b\u3088\u308b\u9ad8\u611f\u5ea6\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u5206\u6790 \u672c\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u30ab\u30e9\u30e0\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u30e1\u30ab\u30cb\u30ba\u30e0\u306b\u3088\u308a\u521d\u671f\u79fb\u52d5\u76f8\u6761\u4ef6\u4e0b\u3067\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u304c\u5341\u5206\u306b\u4fdd\u6301\u3055\u308c\u308b\u305f\u3081\u3001\u30dc\u30c8\u30eb\u5165\u308a\u98f2\u6599\u6c34\u3092500 \u00b5L\u306e\u5927\u5bb9\u91cf\u3067\u76f4\u63a5\u6ce8\u5165\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u4f4e\u6fc3\u5ea6\u57df\u306e\u611f\u5ea6\u3092\u7c21\u4fbf\u306b\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4fdd\u6301\u30fb\u6eb6\u51fa\u7279\u6027\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u3001\u79fb\u52d5\u76f8\u6dfb\u52a0\u5264\u3068pH\u3092\u7cbe\u67fb\u3057\u3001\u9069\u5207\u306a\u4fdd\u6301\u304a\u3088\u3073\u826f\u597d\u306a\u611f\u5ea6\u3092\u4e0e\u3048\u308b\u8377\u96fb\u72b6\u614b\u306b\u8abf\u6574\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001LC\u30b7\u30b9\u30c6\u30e0\u3078\u306e\u4e00\u5ea6\u9650\u308a\u306e\u4e0d\u52d5\u614b\u5316\uff08\u30d1\u30c3\u30b7\u30d9\u30fc\u30b7\u30e7\u30f3\uff09\u51e6\u7406\uff08\u5206\u6790\u30ab\u30e9\u30e0\u304a\u3088\u3073\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u5916\u3057\u305f\u72b6\u614b\u3067\u5b9f\u65bd\uff09\u306b\u3088\u308a\u4e0d\u8981\u306a\u30ad\u30ec\u30fc\u30c8\u5f62\u6210\u3092\u6291\u5236\u3057\u305f\u3068\u3053\u308d\u3001100 ppt\uff08SN\u6bd4 > 50\uff09\u3067\u826f\u597d\u306a\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n","protected":false},"author":11,"featured_media":6712,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2274],"post-badge":[],"resource-type":[],"product-library":[2571,2553],"resource-technique":[2365,2343],"ppma_author":[414],"class_list":["post-95617","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","industries-application-food-beverage-ja","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-ms-ms-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA3196-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":789,"category_count":509,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95617","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=95617"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95617\/revisions"}],"predecessor-version":[{"id":96788,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/95617\/revisions\/96788"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6712"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=95617"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=95617"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=95617"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=95617"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=95617"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=95617"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=95617"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=95617"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=95617"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}