{"id":96892,"date":"2020-10-27T00:00:00","date_gmt":"2020-10-27T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=96892"},"modified":"2026-06-14T23:13:32","modified_gmt":"2026-06-14T23:13:32","slug":"how-much-sensitivity-is-needed-in-a-leak-detector","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar2999-ja\/how-much-sensitivity-is-needed-in-a-leak-detector","title":{"rendered":"\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306f\u5fc5\u8981\u304b\uff1f\u2015\u88c5\u7f6e\u306e\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u304c\u898b\u9003\u3057\u3066\u3044\u308b\u30ea\u30fc\u30af"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>\u88c5\u7f6e\u306e\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u3092\u30d1\u30b9\u3057\u3066\u3057\u307e\u3046\u5fae\u5c0f\u30ea\u30fc\u30af\u3082\u691c\u51fa\u3057\u3001\u30c7\u30fc\u30bf\u3068\u6a5f\u5668\u3092\u5b88\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30ea\u30fc\u30af\u3092\u9632\u3050\u3053\u3068\u3067\u3001\u9ad8\u4fa1\u306a\u30ab\u30e9\u30e0\u3084\u518d\u8abf\u88fd\u3067\u304d\u306a\u3044\u30b5\u30f3\u30d7\u30eb\u3092\u5b88\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u88c5\u7f6e\u3092\u30aa\u30d5\u30e9\u30a4\u30f3\u306b\u305b\u305a\u3001\u624b\u8efd\u306b\u30ea\u30fc\u30af\u78ba\u8a8d\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading\" style=\"font-size:27px\">GC\u88c5\u7f6e\u306e\u30ea\u30fc\u30af\u304c\u5f15\u304d\u8d77\u3053\u3059\u5206\u6790\u4e0a\u306e\u554f\u984c\u3068\u30b3\u30b9\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u88c5\u7f6e\u306e\u30ea\u30fc\u30af\u306f\u3001\u4fdd\u6301\u6642\u9593\u306e\u30b7\u30d5\u30c8\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e0a\u6607\u3068\u3044\u3063\u305f\u5206\u6790\u4e0a\u306e\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7121\u99c4\u306a\u6d88\u8cbb\u3084\u30ab\u30e9\u30e0\u5bff\u547d\u306e\u77ed\u7e2e\u306b\u3088\u308b\u30b3\u30b9\u30c8\u5897\u3082\u898b\u9003\u305b\u307e\u305b\u3093\u3002\u3055\u3089\u306b\u6700\u60aa\u306e\u5834\u5408\u3001\u5206\u6790\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u305d\u306e\u3082\u306e\u304c\u5931\u308f\u308c\u3001\u7d50\u679c\u304c\u4e0d\u78ba\u5b9a\u3042\u308b\u3044\u306f\u8aa4\u3063\u305f\u3082\u306e\u306b\u306a\u308a\u304b\u306d\u307e\u305b\u3093\u3002\u3053\u3046\u3057\u305f\u554f\u984c\u3092\u672a\u7136\u306b\u9632\u3050\u30c4\u30fc\u30eb\u3068\u3057\u3066<a href=\"https:\/\/www.restek.com\/p\/28500\" target=\"_blank\" rel=\"noreferrer noopener\">\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/a>\u306f\u6709\u52b9\u3067\u3059\u304c\u3001\u9ad8\u611f\u5ea6\u30e2\u30c7\u30eb\u306f\u9ad8\u4fa1\u3067\u3042\u308a\u3001\u8cbb\u7528\u5bfe\u52b9\u679c\u306e\u89b3\u70b9\u304b\u3089\u5c0e\u5165\u3092\u305f\u3081\u3089\u3046\u30b1\u30fc\u30b9\u3082\u3042\u308a\u307e\u3059\u3002\u3067\u306f\u5b9f\u969b\u306e\u3068\u3053\u308d\u3001\u6a5f\u5668\u3068\u30c7\u30fc\u30bf\u3092\u5b88\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a\u611f\u5ea6\u306f\u3069\u306e\u7a0b\u5ea6\u306a\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading\" style=\"font-size:27px\">\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306e\u6027\u80fd\u8a55\u4fa1\uff5c\u88c5\u7f6e\u306e\u6a19\u6e96\u30c6\u30b9\u30c8\u3067\u306f\u4e0d\u5341\u5206\u306a\u7406\u7531<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306e\u6027\u80fd\u306f\u30ea\u30fc\u30af\u30ec\u30fc\u30c8\uff08atm cc\/sec\uff09\u3067\u8868\u793a\u3055\u308c\u308b\u306e\u304c\u4e00\u822c\u7684\u3067\u3059\u304c\u3001\u3053\u306e\u6570\u5024\u3060\u3051\u3067\u306f\u300c\u5206\u6790\u306b\u5f71\u97ff\u3059\u308b\u30ea\u30fc\u30af\u3092\u5b9f\u969b\u306b\u691c\u51fa\u3067\u304d\u308b\u304b\u300d\u306f\u5224\u65ad\u3067\u304d\u307e\u305b\u3093\u3002\u3088\u308a\u5b9f\u8df5\u7684\u306a\u8a55\u4fa1\u65b9\u6cd5\u3068\u3057\u3066\u3001\u6f0f\u308c\u91cf\u3092\u5236\u5fa1\u3057\u305f\u30ea\u30fc\u30af\u3092\u610f\u56f3\u7684\u306b\u767a\u751f\u3055\u305b\u305f\u3046\u3048\u3067\u3001\u88c5\u7f6e\u30e1\u30fc\u30ab\u30fc\u304c\u5b9a\u3081\u308b\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\uff08\u5727\u529b\u964d\u4e0b\u91cf\u3092\u6e2c\u5b9a\u3059\u308b\u30c6\u30b9\u30c8\uff09\u3068\u7167\u3089\u3057\u5408\u308f\u305b\u308b\u624b\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u306f\u591a\u304f\u306e\u88c5\u7f6e\u30e1\u30fc\u30ab\u30fc\u304c\u6ce8\u5165\u53e3\u306e\u30ea\u30fc\u30af\u78ba\u8a8d\u624b\u9806\u3068\u3057\u3066\u516c\u958b\u3057\u3066\u304a\u308a\u3001\u4e00\u822c\u7684\u306b\u306f\u6ce8\u5165\u53e3\u306e\u51fa\u53e3\u3092\u3059\u3079\u3066\u30b7\u30fc\u30eb\u3057\u3066\u52a0\u5727\u3057\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u91cf\u3092\u30bc\u30ed\u306b\u3057\u305f\u72b6\u614b\u3067\u5727\u529b\u306e\u964d\u4e0b\u901f\u5ea6\u3092\u76e3\u8996\u3057\u307e\u3059\u3002Agilent\u306e\u624b\u9806\u66f8\u3092\u4f8b\u306b\u3068\u308b\u3068\u300110\u5206\u9593\u30670.5 psi\u3092\u8d85\u3048\u308b\u5727\u529b\u4f4e\u4e0b\u304c\u3042\u308c\u3070\u3001\u5206\u6790\u306b\u5f71\u97ff\u3059\u308b\u30ea\u30fc\u30af\u304c\u5b58\u5728\u3059\u308b\u3068\u5224\u65ad\u3055\u308c\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading\" style=\"font-size:27px\">Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306e\u691c\u51fa\u6027\u80fd\uff5c\u5fae\u5c0f\u30ea\u30fc\u30af\u306e\u5b9f\u8a3c\u3068\u5c0e\u5165\u30e1\u30ea\u30c3\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u3067\u306f\u3001\u3053\u306eAgilent\u57fa\u6e96\u306b\u76f8\u5f53\u3059\u308b\u30ea\u30fc\u30af\u3092Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3067\u691c\u51fa\u3067\u304d\u308b\u304b\u3092\u691c\u8a3c\u3057\u307e\u3057\u305f\u3002\u30bb\u30d7\u30bf\u30e0\u306b\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30c1\u30e5\u30fc\u30d6\u3092\u8cab\u901a\u3055\u305b\u3066\u30d4\u30f3\u30db\u30fc\u30eb\u30ea\u30fc\u30af\u3092\u767a\u751f\u3055\u305b\u3066\u3001\u30c1\u30e5\u30fc\u30d6\u306e\u9577\u3055\u3068\u5185\u5f84\u3092\u5909\u3048\u306a\u304c\u3089\u5727\u529b\u964d\u4e0b\u901f\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u3067\u6f0f\u308c\u91cf\u3092\u8abf\u6574\u3057\u307e\u3057\u305f\u3002\u5185\u5f8415 \u00b5m\u30fb\u9577\u30553 cm\u306e\u30c1\u30e5\u30fc\u30d6\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u300110\u5206\u9593\u30670.3 psi\u306e\u5727\u529b\u4f4e\u4e0b\u3092\u793a\u3059\u30ea\u30fc\u30af\u3092\u518d\u73fe\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30ea\u30fc\u30af\u91cf\u306fAgilent\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u5408\u683c\u3059\u308b\u5024\u3067\u3059\u3002\u3053\u306e\u30ea\u30fc\u30af\u306b\u5bfe\u3057\u3066Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u7528\u3057\u305f\u3068\u3053\u308d\u3001\u6ce8\u5165\u53e3\u306e\u30ea\u30fc\u30af\u304c\u78ba\u5b9f\u306b\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u3002\u3064\u307e\u308a\u3001\u88c5\u7f6e\u30e1\u30fc\u30ab\u30fc\u306e\u6a19\u6e96\u7684\u306a\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u3092\u30d1\u30b9\u3057\u3066\u3057\u307e\u3046\u3088\u3046\u306a\u30ea\u30fc\u30af\u3067\u3055\u3048\u3082\u78ba\u5b9f\u306b\u691c\u51fa\u3067\u304d\u308b\u3053\u3068\u304c\u5b9f\u8a3c\u3055\u308c\u307e\u3057\u305f(<strong>Figure 1<\/strong>).<\/p>\n<\/div>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:20px\"><strong>Figure 1:<\/strong>&nbsp;Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306f\u3001\u88c5\u7f6e\u306e\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u3067\u306f\u5408\u683c\u3068\u306a\u308b\u3088\u3046\u306a\u5fae\u91cf\u30ea\u30fc\u30af\u3092\u691c\u51fa<\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"700\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-1024x700.jpg\" alt=\"\" class=\"wp-image-20806\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-1024x700.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-300x205.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-768x525.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-1536x1050.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3046\u3057\u305f\u7d50\u679c\u304b\u3089\u3082\u660e\u3089\u304b\u306a\u3088\u3046\u306b\u3001\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306fGC\u30e9\u30dc\u306b\u6b20\u304b\u305b\u306a\u3044\u30c4\u30fc\u30eb\u3067\u3059\u3002Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306a\u3089\u3001\u88c5\u7f6e\u3092\u30aa\u30d5\u30e9\u30a4\u30f3\u306b\u3059\u308b\u3053\u3068\u306a\u304f\u624b\u8efd\u306b\u4f7f\u3048\u308b\u3046\u3048\u3001\u6a19\u6e96\u7684\u306a\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u3067\u306f\u898b\u9003\u3055\u308c\u308b\u30ec\u30d9\u30eb\u306e\u30ea\u30fc\u30af\u3082\u78ba\u5b9f\u306b\u691c\u51fa\u3067\u304d\u307e\u3059\u3002\u9ad8\u4fa1\u306a\u30ab\u30e9\u30e0\u3084\u518d\u8abf\u88fd\u3067\u304d\u306a\u3044\u30b5\u30f3\u30d7\u30eb\u3092\u5b88\u308b\u3053\u3068\u3092\u8003\u3048\u308c\u3070\u3001\u5c0e\u5165\u30b3\u30b9\u30c8\u306f\u3059\u3050\u306b\u56de\u53ce\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>GC\u88c5\u7f6e\u306e\u30ea\u30fc\u30af\u304c\u5f15\u304d\u8d77\u3053\u3059\u5206\u6790\u4e0a\u306e\u554f\u984c\u3068\u30b3\u30b9\u30c8 GC\u88c5\u7f6e\u306e\u30ea\u30fc\u30af\u306f\u3001\u4fdd\u6301\u6642\u9593\u306e\u30b7\u30d5\u30c8\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e0a\u6607\u3068\u3044\u3063\u305f\u5206\u6790\u4e0a\u306e\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7121\u99c4\u306a\u6d88\u8cbb\u3084\u30ab\u30e9\u30e0\u5bff\u547d\u306e\u77ed\u7e2e\u306b\u3088\u308b\u30b3\u30b9\u30c8\u5897\u3082\u898b\u9003\u305b\u307e\u305b\u3093\u3002\u3055\u3089\u306b\u6700\u60aa\u306e\u5834\u5408\u3001\u5206\u6790\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u305d\u306e\u3082\u306e\u304c\u5931\u308f\u308c\u3001\u7d50\u679c\u304c\u4e0d\u78ba\u5b9a\u3042\u308b\u3044\u306f\u8aa4\u3063\u305f\u3082\u306e\u306b\u306a\u308a\u304b\u306d\u307e\u305b\u3093\u3002\u3053\u3046\u3057\u305f\u554f\u984c\u3092\u672a\u7136\u306b\u9632\u3050\u30c4\u30fc\u30eb\u3068\u3057\u3066\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306f\u6709\u52b9\u3067\u3059\u304c\u3001\u9ad8\u611f\u5ea6\u30e2\u30c7\u30eb\u306f\u9ad8\u4fa1\u3067\u3042\u308a\u3001\u8cbb\u7528\u5bfe\u52b9\u679c\u306e\u89b3\u70b9\u304b\u3089\u5c0e\u5165\u3092\u305f\u3081\u3089\u3046\u30b1\u30fc\u30b9\u3082\u3042\u308a\u307e\u3059\u3002\u3067\u306f\u5b9f\u969b\u306e\u3068\u3053\u308d\u3001\u6a5f\u5668\u3068\u30c7\u30fc\u30bf\u3092\u5b88\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a\u611f\u5ea6\u306f\u3069\u306e\u7a0b\u5ea6\u306a\u306e\u3067\u3057\u3087\u3046\u304b\u3002 \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306e\u6027\u80fd\u8a55\u4fa1\uff5c\u88c5\u7f6e\u306e\u6a19\u6e96\u30c6\u30b9\u30c8\u3067\u306f\u4e0d\u5341\u5206\u306a\u7406\u7531 \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306e\u6027\u80fd\u306f\u30ea\u30fc\u30af\u30ec\u30fc\u30c8\uff08atm cc\/sec\uff09\u3067\u8868\u793a\u3055\u308c\u308b\u306e\u304c\u4e00\u822c\u7684\u3067\u3059\u304c\u3001\u3053\u306e\u6570\u5024\u3060\u3051\u3067\u306f\u300c\u5206\u6790\u306b\u5f71\u97ff\u3059\u308b\u30ea\u30fc\u30af\u3092\u5b9f\u969b\u306b\u691c\u51fa\u3067\u304d\u308b\u304b\u300d\u306f\u5224\u65ad\u3067\u304d\u307e\u305b\u3093\u3002\u3088\u308a\u5b9f\u8df5\u7684\u306a\u8a55\u4fa1\u65b9\u6cd5\u3068\u3057\u3066\u3001\u6f0f\u308c\u91cf\u3092\u5236\u5fa1\u3057\u305f\u30ea\u30fc\u30af\u3092\u610f\u56f3\u7684\u306b\u767a\u751f\u3055\u305b\u305f\u3046\u3048\u3067\u3001\u88c5\u7f6e\u30e1\u30fc\u30ab\u30fc\u304c\u5b9a\u3081\u308b\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\uff08\u5727\u529b\u964d\u4e0b\u91cf\u3092\u6e2c\u5b9a\u3059\u308b\u30c6\u30b9\u30c8\uff09\u3068\u7167\u3089\u3057\u5408\u308f\u305b\u308b\u624b\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u306f\u591a\u304f\u306e\u88c5\u7f6e\u30e1\u30fc\u30ab\u30fc\u304c\u6ce8\u5165\u53e3\u306e\u30ea\u30fc\u30af\u78ba\u8a8d\u624b\u9806\u3068\u3057\u3066\u516c\u958b\u3057\u3066\u304a\u308a\u3001\u4e00\u822c\u7684\u306b\u306f\u6ce8\u5165\u53e3\u306e\u51fa\u53e3\u3092\u3059\u3079\u3066\u30b7\u30fc\u30eb\u3057\u3066\u52a0\u5727\u3057\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u91cf\u3092\u30bc\u30ed\u306b\u3057\u305f\u72b6\u614b\u3067\u5727\u529b\u306e\u964d\u4e0b\u901f\u5ea6\u3092\u76e3\u8996\u3057\u307e\u3059\u3002Agilent\u306e\u624b\u9806\u66f8\u3092\u4f8b\u306b\u3068\u308b\u3068\u300110\u5206\u9593\u30670.5 psi\u3092\u8d85\u3048\u308b\u5727\u529b\u4f4e\u4e0b\u304c\u3042\u308c\u3070\u3001\u5206\u6790\u306b\u5f71\u97ff\u3059\u308b\u30ea\u30fc\u30af\u304c\u5b58\u5728\u3059\u308b\u3068\u5224\u65ad\u3055\u308c\u307e\u3059\u3002 Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306e\u691c\u51fa\u6027\u80fd\uff5c\u5fae\u5c0f\u30ea\u30fc\u30af\u306e\u5b9f\u8a3c\u3068\u5c0e\u5165\u30e1\u30ea\u30c3\u30c8 Restek\u3067\u306f\u3001\u3053\u306eAgilent\u57fa\u6e96\u306b\u76f8\u5f53\u3059\u308b\u30ea\u30fc\u30af\u3092Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3067\u691c\u51fa\u3067\u304d\u308b\u304b\u3092\u691c\u8a3c\u3057\u307e\u3057\u305f\u3002\u30bb\u30d7\u30bf\u30e0\u306b\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30c1\u30e5\u30fc\u30d6\u3092\u8cab\u901a\u3055\u305b\u3066\u30d4\u30f3\u30db\u30fc\u30eb\u30ea\u30fc\u30af\u3092\u767a\u751f\u3055\u305b\u3066\u3001\u30c1\u30e5\u30fc\u30d6\u306e\u9577\u3055\u3068\u5185\u5f84\u3092\u5909\u3048\u306a\u304c\u3089\u5727\u529b\u964d\u4e0b\u901f\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u3067\u6f0f\u308c\u91cf\u3092\u8abf\u6574\u3057\u307e\u3057\u305f\u3002\u5185\u5f8415 \u00b5m\u30fb\u9577\u30553 cm\u306e\u30c1\u30e5\u30fc\u30d6\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u300110\u5206\u9593\u30670.3 psi\u306e\u5727\u529b\u4f4e\u4e0b\u3092\u793a\u3059\u30ea\u30fc\u30af\u3092\u518d\u73fe\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30ea\u30fc\u30af\u91cf\u306fAgilent\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u5408\u683c\u3059\u308b\u5024\u3067\u3059\u3002\u3053\u306e\u30ea\u30fc\u30af\u306b\u5bfe\u3057\u3066Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u7528\u3057\u305f\u3068\u3053\u308d\u3001\u6ce8\u5165\u53e3\u306e\u30ea\u30fc\u30af\u304c\u78ba\u5b9f\u306b\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u3002\u3064\u307e\u308a\u3001\u88c5\u7f6e\u30e1\u30fc\u30ab\u30fc\u306e\u6a19\u6e96\u7684\u306a\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u3092\u30d1\u30b9\u3057\u3066\u3057\u307e\u3046\u3088\u3046\u306a\u30ea\u30fc\u30af\u3067\u3055\u3048\u3082\u78ba\u5b9f\u306b\u691c\u51fa\u3067\u304d\u308b\u3053\u3068\u304c\u5b9f\u8a3c\u3055\u308c\u307e\u3057\u305f(Figure 1). Figure 1:&nbsp;Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306f\u3001\u88c5\u7f6e\u306e\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u3067\u306f\u5408\u683c\u3068\u306a\u308b\u3088\u3046\u306a\u5fae\u91cf\u30ea\u30fc\u30af\u3092\u691c\u51fa \u3053\u3046\u3057\u305f\u7d50\u679c\u304b\u3089\u3082\u660e\u3089\u304b\u306a\u3088\u3046\u306b\u3001\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306fGC\u30e9\u30dc\u306b\u6b20\u304b\u305b\u306a\u3044\u30c4\u30fc\u30eb\u3067\u3059\u3002Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306a\u3089\u3001\u88c5\u7f6e\u3092\u30aa\u30d5\u30e9\u30a4\u30f3\u306b\u3059\u308b\u3053\u3068\u306a\u304f\u624b\u8efd\u306b\u4f7f\u3048\u308b\u3046\u3048\u3001\u6a19\u6e96\u7684\u306a\u30ea\u30fc\u30af\u30c6\u30b9\u30c8\u3067\u306f\u898b\u9003\u3055\u308c\u308b\u30ec\u30d9\u30eb\u306e\u30ea\u30fc\u30af\u3082\u78ba\u5b9f\u306b\u691c\u51fa\u3067\u304d\u307e\u3059\u3002\u9ad8\u4fa1\u306a\u30ab\u30e9\u30e0\u3084\u518d\u8abf\u88fd\u3067\u304d\u306a\u3044\u30b5\u30f3\u30d7\u30eb\u3092\u5b88\u308b\u3053\u3068\u3092\u8003\u3048\u308c\u3070\u3001\u5c0e\u5165\u30b3\u30b9\u30c8\u306f\u3059\u3050\u306b\u56de\u53ce\u3067\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2387,2372],"resource-technique":[2294],"ppma_author":[414],"class_list":["post-96892","post","type-post","status-publish","format-standard","hentry","category-articles-ja","product-library-instrument-supplies-tools","product-library-gas-chromatography-products","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2387,"label":"Instrument Supplies &amp; Tools"},{"value":2372,"label":"Gas Chromatography Products"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/96892","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=96892"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/96892\/revisions"}],"predecessor-version":[{"id":96909,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/96892\/revisions\/96909"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=96892"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=96892"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=96892"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=96892"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=96892"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=96892"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=96892"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=96892"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=96892"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}