{"id":96899,"date":"2020-10-20T14:30:00","date_gmt":"2020-10-20T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=96899"},"modified":"2026-06-14T23:54:05","modified_gmt":"2026-06-14T23:54:05","slug":"leak-checking-a-gc-system","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/artikel\/gnar3221-ja\/leak-checking-a-gc-system","title":{"rendered":"GC\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af"},"content":{"rendered":"\n<div style=\"height:55px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading\" style=\"font-size:27px\">GC\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u304c\u5f15\u304d\u8d77\u3053\u3059\u554f\u984c\uff5c\u898b\u3048\u306a\u3044\u30ea\u30fc\u30af\u3092\u898b\u9003\u3059\u30ea\u30b9\u30af<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u300c\u81ea\u5206\u306eGC\u30b7\u30b9\u30c6\u30e0\u306b\u30ea\u30fc\u30af\u306f\u306a\u3044\u306f\u305a\u300d\u2015\u2015\u305d\u3046\u601d\u3063\u3066\u3044\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306f\u5c11\u306a\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u30b7\u30b9\u30c6\u30e0\u306b\u672c\u5f53\u306b\u30ea\u30fc\u30af\u304c\u306a\u3044\u3053\u3068\u3092\u78ba\u8a8d\u3067\u304d\u308b\u30c4\u30fc\u30eb\u3092\u3001\u3042\u306a\u305f\u306f\u6301\u3063\u3066\u3044\u308b\u3067\u3057\u3087\u3046\u304b\u3002Restek\u306f\u3001\u5206\u6790\u6027\u80fd\u306e\u5411\u4e0a\u3001\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u524a\u6e1b\u3001\u305d\u3057\u3066\u30ab\u30e9\u30e0\u3084\u9ad8\u611f\u5ea6\u691c\u51fa\u5668\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u3063\u305f\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u30eb\u30fc\u30c1\u30f3\u4f5c\u696d\u306b\u7d44\u307f\u8fbc\u3080\u3053\u3068\u3092\u5f37\u304f\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306f\u3001<strong>\u7701\u304f\u3053\u3068\u306e\u3067\u304d\u306a\u3044<\/strong>\u91cd\u8981\u306a\u4e88\u9632\u4fdd\u5168\u3067\u3042\u308a\u3001\u512a\u308c\u305f\u30e9\u30dc\u5b9f\u8df5\uff08good laboratory practice: GLP\uff09\u306e\u4e00\u74b0\u3067\u3059\u3002\u30ea\u30fc\u30af\u306f\u3001\u4fa1\u683c\u304c\u5e74\u3005\u4e0a\u6607\u3059\u308b\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u7121\u99c4\u306a\u6d88\u8cbb\u3001\u30c8\u30e9\u30c3\u30d7\u3084\u7cbe\u88fd\u7ba1\u306e\u5bff\u547d\u77ed\u7e2e\u3001\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u306e\u5897\u52a0\u3001\u30b7\u30b9\u30c6\u30e0\u304a\u3088\u3073\u691c\u51fa\u5668\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u983b\u5ea6\u306e\u5897\u52a0\u3068\u3044\u3063\u305f\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u307e\u305f\u3001ECD\u306a\u3069\u4e00\u90e8\u306e\u691c\u51fa\u5668\u306f\u3001\u30ea\u30fc\u30af\u306b\u3088\u308b\u9178\u7d20\u3078\u306e\u66b4\u9732\u3067\u6df1\u523b\u306a\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u914d\u7ba1\u4f5c\u696d\u306e\u904e\u7a0b\u304a\u3088\u3073\u5b9a\u671f\u7684\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3068\u3057\u3066\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u672c\u4f53\u3060\u3051\u3067\u306a\u304f\u30b7\u30b9\u30c6\u30e0\u5168\u4f53\u3092\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3059\u308b\u3053\u3068\u3067\u3001\u591a\u304f\u306e\u30c8\u30e9\u30d6\u30eb\u3092\u672a\u7136\u306b\u9632\u3050\u304b\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002HPLC\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u30ea\u30fc\u30af\u304c\u76ee\u306b\u898b\u3048\u308b\u5f62\u3067\u73fe\u308c\u307e\u3059\u304c\u3001GC\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u306f\u5fae\u5999\u3067\u3001\u9069\u5207\u306a\u6a5f\u5668\u306a\u3057\u306b\u7279\u5b9a\u3059\u308b\u306e\u304c\u96e3\u3057\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u958b\u59cb\u3059\u308b\u524d\u306b\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3044\u3001\u3059\u3079\u3066\u306e\u30ea\u30fc\u30af\u3092\u89e3\u6d88\u3057\u3066\u304b\u3089\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u304a\u3088\u3073\u5206\u6790\u4f5c\u696d\u306b\u9032\u3080\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading\" style=\"font-size:27px\">\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306e\u624b\u9806\uff5c\u30ac\u30b9\u4f9b\u7d66\u6e90\u304b\u3089\u30ab\u30e9\u30e0\u63a5\u7d9a\u90e8\u307e\u3067<\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">\u30c1\u30a7\u30c3\u30af\u306e\u624b\u9806\u3068\u3057\u3066\u306f\u3001<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u307e\u305a\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u4f9b\u7d66\u6e90\u3068\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u304b\u3089\u59cb\u3081\u3001GC\u307e\u3067\u306e\u7d4c\u8def\u306b\u6cbf\u3063\u3066\u3059\u3079\u3066\u306e\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3068\u63a5\u7d9a\u90e8\u3092\u4e01\u5be7\u306b\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30aa\u30fc\u30d6\u30f3\u30d5\u30a1\u30f3\u3092\u6b62\u3081\u3066\u3001\u30aa\u30fc\u30d6\u30f3\u5185\u306e\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3001\u30a2\u30c0\u30d7\u30bf\u3001\u63a5\u7d9a\u90e8\u3082\u30c1\u30a7\u30c3\u30af\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u304a\u3088\u3073\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u63a5\u7d9a\u90e8\uff08\u30b3\u30cd\u30af\u30bf\u3084\u30e6\u30cb\u30aa\u30f3\u3092\u542b\u3080\uff09\u3082\u5fd8\u308c\u305a\u306b\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002\u30ea\u30fc\u30af\u306e\u539f\u56e0\u3068\u3057\u3066\u3001\u53d6\u308a\u4ed8\u3051\u6642\u306b\u30ab\u30e9\u30e0\u7aef\u304c\u6f70\u308c\u3066\u3044\u308b\u30b1\u30fc\u30b9\u3082\u591a\u304f\u898b\u3089\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading\" style=\"font-size:27px\">Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u3063\u305f\u6b63\u3057\u3044\u30ea\u30fc\u30af\u691c\u51fa\u65b9\u6cd5<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306b\u6700\u9069\u306a\u65b9\u6cd5\u306f\u3001<a href=\"https:\/\/www.restek.com\/p\/28500\" target=\"_blank\" rel=\"noreferrer noopener\">Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/a> (cat.# 28500)\u306e\u3088\u3046\u306a\u71b1\u4f1d\u5c0e\u5f0f\u30ea\u30fc\u30af\u691c\u51fa\u5668\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u3053\u306e\u30dd\u30fc\u30bf\u30d6\u30eb\u3067\u4fe1\u983c\u6027\u304c\u9ad8\u3044\u30cf\u30f3\u30c9\u30d8\u30eb\u30c9\u6a5f\u5668\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u3092\u6c5a\u67d3\u3059\u308b\u3053\u3068\u306a\u304f\u30d8\u30ea\u30a6\u30e0\u307e\u305f\u306f\u6c34\u7d20\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u5fae\u91cf\u6f0f\u308c\u3092\u691c\u51fa\u3057\u307e\u3059\u3002GC\/MS\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u306f\u3001\u8cea\u91cf28\uff08\u7a92\u7d20\uff09\u307e\u305f\u306f\u8cea\u91cf32\uff08\u9178\u7d20\uff09\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u304b\u3001\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3084\u63a5\u7d9a\u90e8\u306b\u30a2\u30eb\u30b4\u30f3\u30ac\u30b9\u3092\u5439\u304d\u304b\u3051\u3066\u8cea\u91cf40\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u306a\u304a\u3001<strong>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u306f\u3001\u77f3\u9e78\u3084\u754c\u9762\u6d3b\u6027\u5264\u3092\u542b\u3080\u6db2\u4f53\u30ea\u30fc\u30af\u691c\u77e5\u5264\u306e\u4f7f\u7528\u306f\u907f\u3051\u3066\u304f\u3060\u3055\u3044<\/strong>\u3002\u30ea\u30fc\u30af\u304c\u3042\u308b\u3068\u3001\u5727\u529b\u5dee\u306b\u3088\u3063\u3066\u3053\u308c\u3089\u306e\u7269\u8cea\u304c\u30b7\u30b9\u30c6\u30e0\u5185\u306b\u5f15\u304d\u8fbc\u307e\u308c\uff08\u30d9\u30f3\u30c1\u30e5\u30ea\u52b9\u679c\uff09\u3001\u30ab\u30e9\u30e0\u3092\u6c5a\u67d3\u3057\u3066\u9ad8\u611f\u5ea6\u5206\u6790\u304c\u56f0\u96e3\u306b\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u6db2\u4f53\u30ea\u30fc\u30af\u691c\u77e5\u5264\u306f\u56fa\u5b9a\u76f8\u306b\u6c38\u7d9a\u7684\u306a\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:35px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h2 class=\"wp-block-heading\" style=\"font-size:27px\">\u30ea\u30fc\u30af\u306e\u306a\u3044GC\u30b7\u30b9\u30c6\u30e0\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\uff5c\u4e88\u9632\u4fdd\u5168\u306e\u9244\u5247<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u3068\u3081\u308b\u3068\u3001\u3059\u3079\u3066\u306eGC\u30e9\u30dc\u306f\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u5099\u3048\u3001<strong>\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3084\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u53d6\u308a\u4ed8\u3051\u6642<\/strong>\u3001<strong>\u30b7\u30ea\u30f3\u30c0\u30fc\u306e\u4ea4\u63db\u6642<\/strong>\u3001\u307e\u305f\u306f<strong>\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u5fc5\u8981\u306a\u969b<\/strong>\u306b\u306f\u5fc5\u305a\u3053\u306e\u30c4\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3088\u3046\u3001\u3059\u3079\u3066\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u304c\u7fd2\u5f97\u3057\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3068\u691c\u51fa\u5668\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u9632\u3050\u305f\u3081\u306b\u3001<strong>\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306a\u3057\u306b\u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u884c\u308f\u306a\u3044\u3053\u3068\u304c\u9244\u5247<\/strong>\u3067\u3059\u3002\u30ea\u30fc\u30af\u306e\u306a\u3044\u30b7\u30b9\u30c6\u30e0\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u3067\u3001\u9577\u671f\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u51e6\u7406\u80fd\u529b\u306e\u5411\u4e0a\u3068\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306e\u524a\u6e1b\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>GC\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u304c\u5f15\u304d\u8d77\u3053\u3059\u554f\u984c\uff5c\u898b\u3048\u306a\u3044\u30ea\u30fc\u30af\u3092\u898b\u9003\u3059\u30ea\u30b9\u30af \u300c\u81ea\u5206\u306eGC\u30b7\u30b9\u30c6\u30e0\u306b\u30ea\u30fc\u30af\u306f\u306a\u3044\u306f\u305a\u300d\u2015\u2015\u305d\u3046\u601d\u3063\u3066\u3044\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306f\u5c11\u306a\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u30b7\u30b9\u30c6\u30e0\u306b\u672c\u5f53\u306b\u30ea\u30fc\u30af\u304c\u306a\u3044\u3053\u3068\u3092\u78ba\u8a8d\u3067\u304d\u308b\u30c4\u30fc\u30eb\u3092\u3001\u3042\u306a\u305f\u306f\u6301\u3063\u3066\u3044\u308b\u3067\u3057\u3087\u3046\u304b\u3002Restek\u306f\u3001\u5206\u6790\u6027\u80fd\u306e\u5411\u4e0a\u3001\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u524a\u6e1b\u3001\u305d\u3057\u3066\u30ab\u30e9\u30e0\u3084\u9ad8\u611f\u5ea6\u691c\u51fa\u5668\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u3063\u305f\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u30eb\u30fc\u30c1\u30f3\u4f5c\u696d\u306b\u7d44\u307f\u8fbc\u3080\u3053\u3068\u3092\u5f37\u304f\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306f\u3001\u7701\u304f\u3053\u3068\u306e\u3067\u304d\u306a\u3044\u91cd\u8981\u306a\u4e88\u9632\u4fdd\u5168\u3067\u3042\u308a\u3001\u512a\u308c\u305f\u30e9\u30dc\u5b9f\u8df5\uff08good laboratory practice: GLP\uff09\u306e\u4e00\u74b0\u3067\u3059\u3002\u30ea\u30fc\u30af\u306f\u3001\u4fa1\u683c\u304c\u5e74\u3005\u4e0a\u6607\u3059\u308b\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u7121\u99c4\u306a\u6d88\u8cbb\u3001\u30c8\u30e9\u30c3\u30d7\u3084\u7cbe\u88fd\u7ba1\u306e\u5bff\u547d\u77ed\u7e2e\u3001\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u306e\u5897\u52a0\u3001\u30b7\u30b9\u30c6\u30e0\u304a\u3088\u3073\u691c\u51fa\u5668\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u983b\u5ea6\u306e\u5897\u52a0\u3068\u3044\u3063\u305f\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u307e\u305f\u3001ECD\u306a\u3069\u4e00\u90e8\u306e\u691c\u51fa\u5668\u306f\u3001\u30ea\u30fc\u30af\u306b\u3088\u308b\u9178\u7d20\u3078\u306e\u66b4\u9732\u3067\u6df1\u523b\u306a\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002 \u914d\u7ba1\u4f5c\u696d\u306e\u904e\u7a0b\u304a\u3088\u3073\u5b9a\u671f\u7684\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3068\u3057\u3066\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u672c\u4f53\u3060\u3051\u3067\u306a\u304f\u30b7\u30b9\u30c6\u30e0\u5168\u4f53\u3092\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3059\u308b\u3053\u3068\u3067\u3001\u591a\u304f\u306e\u30c8\u30e9\u30d6\u30eb\u3092\u672a\u7136\u306b\u9632\u3050\u304b\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002HPLC\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u30ea\u30fc\u30af\u304c\u76ee\u306b\u898b\u3048\u308b\u5f62\u3067\u73fe\u308c\u307e\u3059\u304c\u3001GC\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u306f\u5fae\u5999\u3067\u3001\u9069\u5207\u306a\u6a5f\u5668\u306a\u3057\u306b\u7279\u5b9a\u3059\u308b\u306e\u304c\u96e3\u3057\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u958b\u59cb\u3059\u308b\u524d\u306b\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3044\u3001\u3059\u3079\u3066\u306e\u30ea\u30fc\u30af\u3092\u89e3\u6d88\u3057\u3066\u304b\u3089\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u304a\u3088\u3073\u5206\u6790\u4f5c\u696d\u306b\u9032\u3080\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002 \u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306e\u624b\u9806\uff5c\u30ac\u30b9\u4f9b\u7d66\u6e90\u304b\u3089\u30ab\u30e9\u30e0\u63a5\u7d9a\u90e8\u307e\u3067 \u30c1\u30a7\u30c3\u30af\u306e\u624b\u9806\u3068\u3057\u3066\u306f\u3001 Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u3063\u305f\u6b63\u3057\u3044\u30ea\u30fc\u30af\u691c\u51fa\u65b9\u6cd5 \u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306b\u6700\u9069\u306a\u65b9\u6cd5\u306f\u3001Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf (cat.# 28500)\u306e\u3088\u3046\u306a\u71b1\u4f1d\u5c0e\u5f0f\u30ea\u30fc\u30af\u691c\u51fa\u5668\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u3053\u306e\u30dd\u30fc\u30bf\u30d6\u30eb\u3067\u4fe1\u983c\u6027\u304c\u9ad8\u3044\u30cf\u30f3\u30c9\u30d8\u30eb\u30c9\u6a5f\u5668\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u3092\u6c5a\u67d3\u3059\u308b\u3053\u3068\u306a\u304f\u30d8\u30ea\u30a6\u30e0\u307e\u305f\u306f\u6c34\u7d20\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u5fae\u91cf\u6f0f\u308c\u3092\u691c\u51fa\u3057\u307e\u3059\u3002GC\/MS\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u306f\u3001\u8cea\u91cf28\uff08\u7a92\u7d20\uff09\u307e\u305f\u306f\u8cea\u91cf32\uff08\u9178\u7d20\uff09\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u304b\u3001\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3084\u63a5\u7d9a\u90e8\u306b\u30a2\u30eb\u30b4\u30f3\u30ac\u30b9\u3092\u5439\u304d\u304b\u3051\u3066\u8cea\u91cf40\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002 \u306a\u304a\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u306f\u3001\u77f3\u9e78\u3084\u754c\u9762\u6d3b\u6027\u5264\u3092\u542b\u3080\u6db2\u4f53\u30ea\u30fc\u30af\u691c\u77e5\u5264\u306e\u4f7f\u7528\u306f\u907f\u3051\u3066\u304f\u3060\u3055\u3044\u3002\u30ea\u30fc\u30af\u304c\u3042\u308b\u3068\u3001\u5727\u529b\u5dee\u306b\u3088\u3063\u3066\u3053\u308c\u3089\u306e\u7269\u8cea\u304c\u30b7\u30b9\u30c6\u30e0\u5185\u306b\u5f15\u304d\u8fbc\u307e\u308c\uff08\u30d9\u30f3\u30c1\u30e5\u30ea\u52b9\u679c\uff09\u3001\u30ab\u30e9\u30e0\u3092\u6c5a\u67d3\u3057\u3066\u9ad8\u611f\u5ea6\u5206\u6790\u304c\u56f0\u96e3\u306b\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u6db2\u4f53\u30ea\u30fc\u30af\u691c\u77e5\u5264\u306f\u56fa\u5b9a\u76f8\u306b\u6c38\u7d9a\u7684\u306a\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002 \u30ea\u30fc\u30af\u306e\u306a\u3044GC\u30b7\u30b9\u30c6\u30e0\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\uff5c\u4e88\u9632\u4fdd\u5168\u306e\u9244\u5247 \u307e\u3068\u3081\u308b\u3068\u3001\u3059\u3079\u3066\u306eGC\u30e9\u30dc\u306f\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u5099\u3048\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3084\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u53d6\u308a\u4ed8\u3051\u6642\u3001\u30b7\u30ea\u30f3\u30c0\u30fc\u306e\u4ea4\u63db\u6642\u3001\u307e\u305f\u306f\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u5fc5\u8981\u306a\u969b\u306b\u306f\u5fc5\u305a\u3053\u306e\u30c4\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3088\u3046\u3001\u3059\u3079\u3066\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u304c\u7fd2\u5f97\u3057\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3068\u691c\u51fa\u5668\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306a\u3057\u306b\u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u884c\u308f\u306a\u3044\u3053\u3068\u304c\u9244\u5247\u3067\u3059\u3002\u30ea\u30fc\u30af\u306e\u306a\u3044\u30b7\u30b9\u30c6\u30e0\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u3067\u3001\u9577\u671f\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u51e6\u7406\u80fd\u529b\u306e\u5411\u4e0a\u3068\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306e\u524a\u6e1b\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002<\/p>\n","protected":false},"author":57,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2496,2480],"resource-technique":[2324],"ppma_author":[612],"class_list":["post-96899","post","type-post","status-publish","format-standard","hentry","category-artikel","product-library-detektorzubehor","product-library-gaschromatographie-produkte","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"product-library":[{"value":2496,"label":"Detektorzubeh\u00f6r"},{"value":2480,"label":"Gaschromatographie Produkte"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Tom Bloom","author_link":"https:\/\/discover.restek.com\/ja\/author\/tom-bloom\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":787,"category_count":510,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":612,"user_id":57,"is_guest":0,"slug":"tom-bloom","display_name":"Tom Bloom","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Tom","last_name":"Bloom","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/96899","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/57"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=96899"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/96899\/revisions"}],"predecessor-version":[{"id":96914,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/96899\/revisions\/96914"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=96899"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=96899"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=96899"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=96899"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=96899"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=96899"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=96899"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=96899"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=96899"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}