{"id":97829,"date":"2023-12-08T00:00:00","date_gmt":"2023-12-08T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized-ja\/the-correct-injection-volume-for-split-injections\/"},"modified":"2026-07-13T00:30:39","modified_gmt":"2026-07-13T00:30:39","slug":"the-correct-injection-volume-for-split-injections","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4814-ja\/the-correct-injection-volume-for-split-injections","title":{"rendered":"\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u304a\u3051\u308b\u9069\u5207\u306a\u6ce8\u5165\u91cf"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><style>     ul li { margin-top: 5px; }     ol li { margin-top: 5px; }  <\/style><\/p>\n\n\n\n<style data-wp-block-html=\"css\">\n.rtk-article {\n    --ink: #1c2024;\n    --sub: #5c6470;\n    --line: #e3e6ea;\n    --accent: #0f5b8c;\n    --accent-bg: #eef5fa;\n    --table-head: #f4f6f8;\n    color: var(--ink);\n    line-height: 1.9;\n  }\n\n  .rtk-article h2 {\n    font-size: 21px;\n    font-weight: 700;\n    margin: 52px 0 20px;\n    letter-spacing: 0.01em;\n  }\n\n  .rtk-article h3 {\n    font-size: 16px;\n    font-weight: 700;\n    margin: 32px 0 10px;\n    color: var(--accent);\n  }\n\n  .rtk-article p { margin: 0 0 18px; font-size: 16px; }\n\n  .rtk-article ul { margin: 0 0 18px; padding-left: 1.4em; }\n  .rtk-article li { margin-bottom: 8px; font-size: 16px; }\n\n  .rtk-article .note {\n    background: var(--accent-bg);\n    border-left: 3px solid var(--accent);\n    padding: 16px 20px;\n    border-radius: 4px;\n    font-size: 15px;\n    margin: 24px 0;\n    color: #2a3038;\n  }\n\n  .rtk-article table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 20px 0 8px;\n    font-size: 14.5px;\n  }\n\n  .rtk-article caption {\n    text-align: left;\n    font-size: 13px;\n    color: var(--sub);\n    margin-bottom: 8px;\n    caption-side: top;\n  }\n\n  .rtk-article th, .rtk-article td {\n    padding: 10px 12px;\n    text-align: right;\n    border-bottom: 1px solid var(--line);\n  }\n\n  .rtk-article th:first-child, .rtk-article td:first-child {\n    text-align: left;\n  }\n\n  .rtk-article thead tr th {\n    background: var(--table-head);\n    font-weight: 700;\n    font-size: 13px;\n    color: var(--sub);\n  }\n\n  .rtk-article .tools {\n    margin-top: 12px;\n    padding: 24px;\n    background: var(--table-head);\n    border-radius: 8px;\n  }\n\n  .rtk-article .tools ul { margin-bottom: 0; }\n  .rtk-article .tools strong { color: var(--accent); }\n\n  .rtk-article footer {\n    margin-top: 64px;\n    padding-top: 24px;\n    border-top: 1px solid var(--line);\n    font-size: 13px;\n    color: var(--sub);\n  }\n\n  @media (max-width: 480px) {\n    .rtk-article h2 { font-size: 19px; }\n    .rtk-article table { font-size: 13px; }\n    .rtk-article th, .rtk-article td { padding: 8px 6px; }\n  }\n<\/style>\n\n<div class=\"rtk-article\">\n<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u3001\u9ad8\u6e29\u306e\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306b\u5fc5\u8981\u4ee5\u4e0a\u306e\u91cf\u3092\u6ce8\u5165\u3057\u3066\u3057\u307e\u3046\u30b1\u30fc\u30b9\u304c\u3088\u304f\u898b\u3089\u308c\u307e\u3059\u3002<\/p>\n\n<p>\u6ce8\u5165\u91cf\u304c\u591a\u3059\u304e\u308b\u3068\u3001\u6b21\u306e\u3088\u3046\u306a\u554f\u984c\u304c\u751f\u3058\u307e\u3059\u3002<\/p>\n<ul>\n  <li>\u518d\u73fe\u6027\u306e\u4f4e\u4e0b\uff08\u30d4\u30fc\u30af\u9762\u7a4d\u306e\u3070\u3089\u3064\u304d\uff09<\/li>\n  <li>\u6ce8\u5165\u30b7\u30b9\u30c6\u30e0\u306e\u52a3\u5316\u30fb\u6c5a\u67d3<\/li>\n  <li>\u300c\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u300d\u306e\u767a\u751f \u2192 \u5f8c\u7d9a\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306b\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u304c\u9577\u671f\u9593\u73fe\u308c\u308b\u3053\u3068\u304c\u3042\u308b<\/li>\n<\/ul>\n\n<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u304c\u8d77\u304d\u308b\u4ed5\u7d44\u307f\u306f\u6b21\u306e\u3068\u304a\u308a\u3067\u3059\u3002<\/p>\n<ul>\n  <li>\u6c17\u5316\u3057\u305f\u969b\u306b\u4f53\u7a4d\u304c\u81a8\u5f35\u3057\u3059\u304e\u305f\u84b8\u6c17\u304c\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u30e9\u30a4\u30f3\uff08\u88c5\u7f6e\u306b\u3088\u3063\u3066\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u30e9\u30a4\u30f3\uff09\u3078\u9006\u6d41\u3057\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u5185\u3067\u84c4\u7a4d\u3059\u308b<\/li>\n  <li>\u3053\u306e\u30d5\u30a3\u30eb\u30bf\u30fc\u306f\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u969b\u306b\u5b9a\u671f\u7684\u306b\u4ea4\u63db\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b<\/li>\n  <li>\u84c4\u7a4d\u3057\u305f\u6210\u5206\u306f\u3001\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306e\u7a2e\u985e\u30fb\u6d41\u91cf\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u6761\u4ef6\u306b\u5fdc\u3058\u3066\u5c11\u3057\u305a\u3064\u8131\u96e2\u3059\u308b<\/li>\n  <li>\u8131\u96e2\u3057\u305f\u6210\u5206\u306f\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u3092\u7d4c\u3066\u30ab\u30e9\u30e0\u3078\u904b\u3070\u308c\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4e0a\u306b\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u3068\u3057\u3066\u73fe\u308c\u308b<\/li>\n<\/ul>\n<p>\u306a\u304a\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u3092\u9589\u3058\u305f\u72b6\u614b\u3067\u6c17\u5316\u3092\u884c\u3046\u305f\u3081\u84b8\u6c17\u306e\u9003\u3052\u5834\u304c\u5c11\u306a\u304f\u3001\u6ce8\u5165\u91cf\u304c\u904e\u5270\u306b\u306a\u308b\u3068\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3088\u308a\u3082\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u304c\u8d77\u304d\u3084\u3059\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n<h2>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u304a\u3051\u308b\u9069\u5207\u306a\u6ce8\u5165\u91cf\u306e\u6c7a\u3081\u65b9<\/h2>\n\n<p>\u9069\u5207\u306a\u6ce8\u5165\u91cf\u3092\u6c7a\u3081\u308b\u3046\u3048\u3067\u6700\u3082\u91cd\u8981\u306a\u306e\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u53e3\u3067\u6025\u6fc0\u306b\u84b8\u767a\u3057\u305f\u969b\u306e<strong>\u6c17\u5316\u91cf\uff08\u30b5\u30f3\u30d7\u30eb\u306e\u81a8\u5f35\u4f53\u7a4d\uff09<\/strong>\u3067\u3059\u3002\u3053\u306e\u6c17\u5316\u91cf\u304c\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5bb9\u7a4d\u3092\u8d85\u3048\u308b\u3068\u3001\u30ac\u30b9\u304c\u30e9\u30a4\u30ca\u30fc\u304b\u3089\u3042\u3075\u308c\u51fa\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30e9\u30a4\u30ca\u30fc\u306b\u306f\u3001\u6c17\u5316\u306b\u3088\u3063\u3066\u751f\u3058\u308b\u30ac\u30b9\u306e\u4f53\u7a4d\u3092\u4f59\u88d5\u3092\u3082\u3063\u3066\u53ce\u5bb9\u3067\u304d\u308b\u3060\u3051\u306e\u5927\u304d\u3055\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n\n<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u304a\u3051\u308b\u6700\u5927\u6ce8\u5165\u91cf\u306f\u3001\u4e3b\u306b\u6b21\u306e3\u70b9\u306b\u3088\u3063\u3066\u6c7a\u307e\u308a\u307e\u3059\u3002<\/p>\n\n<h3>1. \u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5bb9\u7a4d<\/h3>\n<p>\u30e9\u30a4\u30ca\u30fc\u306b\u304f\u3073\u308c\uff08\u30c6\u30fc\u30d1\u30fc\u3092\u542b\u3080\u7d5e\u308a\u69cb\u9020\uff09\u3084\u5145\u586b\u7269\uff08\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u306a\u3069\uff09\u304c\u3042\u308b\u3068\u3001\u305d\u306e\u5206\u3001\u6c17\u5316\u3057\u305f\u30ac\u30b9\u3092\u53ce\u5bb9\u3067\u304d\u308b\u5bb9\u7a4d\u304c\u5c0f\u3055\u304f\u306a\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u4e2d\u306f\u3082\u3068\u3082\u3068\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3067\u6e80\u305f\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u6c17\u5316\u3057\u305f\u30ac\u30b9\u3092\u5b9f\u969b\u306b\u53ce\u5bb9\u3067\u304d\u308b\u5bb9\u7a4d\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5bb9\u7a4d\u306e\u8868\u793a\u3088\u308a\u3082\u3055\u3089\u306b\u5c0f\u3055\u304f\u306a\u308b\u3001\u3068\u3044\u3046\u70b9\u3082\u8e0f\u307e\u3048\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n<h3>2. \u4f7f\u7528\u3059\u308b\u6eb6\u5a92<\/h3>\n<p>\u6eb6\u5a92\u304c\u7570\u306a\u308c\u3070\u3001\u6c17\u5316\u91cf\u3082\u5927\u304d\u304f\u5909\u308f\u308a\u307e\u3059\u3002\u76ee\u5b89\u3068\u3057\u3066\u306f\u3001\u6eb6\u5a92\u306e\u6975\u6027\u304c\u9ad8\u3044\u307b\u3069\u6c17\u5316\u91cf\u306f\u5927\u304d\u304f\u306a\u308a\u3001\u306a\u304b\u3067\u3082\u6c34\u306e\u6c17\u5316\u91cf\u304c\u6700\u3082\u5927\u304d\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n<h3>3. \u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u6e29\u5ea6\u3068\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u5727<\/h3>\n<p>\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u6e29\u5ea6\u304c\u9ad8\u3044\u307b\u3069\u3001\u307e\u305f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u5727\u304c\u4f4e\u3044\u307b\u3069\u3001\u6c17\u5316\u91cf\u306f\u5927\u304d\u304f\u306a\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u540c\u3058\u6eb6\u5a92\u30fb\u540c\u3058\u6ce8\u5165\u91cf\u3067\u3082\u3001\u88c5\u7f6e\u306e\u8a2d\u5b9a\u6b21\u7b2c\u3067\u300c\u30e9\u30a4\u30ca\u30fc\u306b\u53ce\u307e\u308b\u304b\u3069\u3046\u304b\u300d\u304c\u5909\u308f\u3063\u3066\u304f\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002<\/p>\n\n<p>\u4ee5\u4e0b\u306f\u30011 \u00b5L\u306e\u5404\u7a2e\u6eb6\u5a92\u3092250\u00b0C\u3067\u84b8\u767a\u3055\u305b\u305f\u5834\u5408\u306e\u6c17\u5316\u91cf\uff08\u00b5L\uff09\u3092\u3001\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u5727\u529b\u5225\u306b\u793a\u3057\u305f\u4f8b\u3067\u3059\u3002<\/p>\n\n<table>\n  <caption>\u5404\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u5727\u529b\u306b\u304a\u3051\u308b\u6c17\u5316\u91cf\uff08\u00b5L\uff09<\/caption>\n  <thead>\n    <tr>\n      <th>\u6eb6\u5a92<\/th>\n      <th>\u5bc6\u5ea6<br>(g\/mL)<\/th>\n      <th>\u5206\u5b50\u91cf<br>(MW)<\/th>\n      <th>5 psig<\/th>\n      <th>10 psig<\/th>\n      <th>15 psig<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr><td>\u30d8\u30d7\u30bf\u30f3<\/td><td>0.68<\/td><td>100<\/td><td>219<\/td><td>174<\/td><td>145<\/td><\/tr>\n    <tr><td>\u30d8\u30ad\u30b5\u30f3<\/td><td>0.66<\/td><td>86<\/td><td>245<\/td><td>224<\/td><td>186<\/td><\/tr>\n    <tr><td>\u30c8\u30eb\u30a8\u30f3<\/td><td>0.87<\/td><td>92<\/td><td>303<\/td><td>242<\/td><td>201<\/td><\/tr>\n    <tr><td>\u9162\u9178\u30a8\u30c1\u30eb<\/td><td>0.90<\/td><td>88<\/td><td>328<\/td><td>261<\/td><td>217<\/td><\/tr>\n    <tr><td>\u30af\u30ed\u30ed\u30db\u30eb\u30e0<\/td><td>1.49<\/td><td>119<\/td><td>400<\/td><td>319<\/td><td>266<\/td><\/tr>\n    <tr><td>\u5869\u5316\u30e1\u30c1\u30ec\u30f3<\/td><td>1.33<\/td><td>85<\/td><td>500<\/td><td>399<\/td><td>332<\/td><\/tr>\n    <tr><td>\u30e1\u30bf\u30ce\u30fc\u30eb<\/td><td>0.79<\/td><td>32<\/td><td>792<\/td><td>629<\/td><td>525<\/td><\/tr>\n    <tr><td>\u6c34<\/td><td>1.00<\/td><td>18<\/td><td>1776<\/td><td>1418<\/td><td>1179<\/td><\/tr>\n  <\/tbody>\n<\/table>\n\n<p>\u3053\u306e\u8868\u304b\u3089\u3082\u5206\u304b\u308b\u3068\u304a\u308a\u3001\u540c\u30581 \u00b5L\u306e\u6ce8\u5165\u3067\u3082\u3001\u6eb6\u5a92\u3068\u5727\u529b\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u3063\u3066\u6c17\u5316\u91cf\u306f10\u500d\u4ee5\u4e0a\u5909\u308f\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u300c\u4f55\u00b5L\u6ce8\u5165\u3057\u3066\u3088\u3044\u304b\u300d\u306f\u3001\u6eb6\u5a92\u30fb\u6e29\u5ea6\u30fb\u5727\u529b\u30fb\u30e9\u30a4\u30ca\u30fc\u5bb9\u91cf\u306e\u7d44\u307f\u5408\u308f\u305b\u3054\u3068\u306b\u500b\u5225\u306b\u8a08\u7b97\u3057\u306a\u3044\u3068\u3001\u6b63\u78ba\u306b\u306f\u6c7a\u307e\u308a\u307e\u305b\u3093\u3002<\/p>\n\n<div class=\"note\">\n  \u306a\u304a\u3001\u5727\u529b\u30d1\u30eb\u30b9\u6ce8\u5165\u3092\u4f7f\u3048\u3070\u3001\u6c17\u5316\u3057\u305f\u8a66\u6599\u306e\u4f53\u7a4d\u3092\u5c0f\u3055\u304f\u6291\u3048\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u6ce8\u5165\u76f4\u5f8c\u306b\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u5727\u3092\u4e00\u6642\u7684\u306b\u9ad8\u3081\u308b\u3053\u3068\u3067\u3001\u6eb6\u5a92\u306e\u81a8\u5f35\u4f53\u7a4d\u304c\u5c0f\u3055\u304f\u306a\u308b\u3068\u3068\u3082\u306b\u3001\u6c17\u5316\u3057\u305f\u8a66\u6599\u3092\u901f\u3084\u304b\u306b\u30ab\u30e9\u30e0\u3078\u9001\u308a\u8fbc\u3080\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u30e9\u30a4\u30ca\u30fc\u304b\u3089\u306e\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u3092\u6291\u5236\u3067\u304d\u307e\u3059\u3002\n<\/div>\n\n<h2>\u5b9f\u969b\u306b\u6ce8\u5165\u91cf\u3092\u6c7a\u3081\u308b\u306b\u306f<\/h2>\n\n<p>\u4e0a\u8a18\u306e\u8a08\u7b97\u3092\u6bce\u56de\u624b\u4f5c\u696d\u3067\u884c\u3046\u306e\u306f\u73fe\u5b9f\u7684\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n<div class=\"tools\">\n  <ul>\n    <li>Restek\u306e\u300c<a href=\"https:\/\/www.restek.com\/global\/ja\/solvent-expansion-calculator\" target=\"_blank\" rel=\"noopener\"><strong>\u6eb6\u5a92\u81a8\u5f35\u8a08\u7b97\u30c4\u30fc\u30eb\uff08Solvent Expansion Calculator\uff09<\/strong><\/a>\u300d\u3092\u4f7f\u3048\u3070\u3001\u6eb6\u5a92\u30fb\u6ce8\u5165\u91cf\u30fb\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u6761\u4ef6\u3092\u5165\u529b\u3059\u308b\u3060\u3051\u3067\u3001\u6c17\u5316\u91cf\u304c\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5bb9\u7a4d\u306b\u53ce\u307e\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/li>\n    <li><a href=\"https:\/\/ez.restek.com\/proezgc\/ja\" target=\"_blank\" rel=\"noopener\"><strong>EZGC Method Translator<\/strong><\/a> \u304a\u3088\u3073 <a href=\"https:\/\/ez.restek.com\/ezgc-mtfc\/ja\" target=\"_blank\" rel=\"noopener\"><strong>Flow Calculator<\/strong><\/a> \u3082\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u30fb\u6700\u9069\u5316\u306b\u5f79\u7acb\u3064\u7121\u6599\u30c4\u30fc\u30eb\u3068\u3057\u3066\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n    <li>\u304a\u4f7f\u3044\u306e\u6ce8\u5165\u6761\u4ef6\u306b\u9069\u3057\u305f\u30e9\u30a4\u30ca\u30fc\u3092\u304a\u63a2\u3057\u306e\u5834\u5408\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1484\" target=\"_blank\" rel=\"noopener\"><strong>Topaz GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc<\/strong><\/a>\u306e\u88fd\u54c1\u4e00\u89a7\u304b\u3089\u3054\u78ba\u8a8d\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/li>\n  <\/ul>\n<\/div>\n\n<footer>\n  GNBL4814-JA\n<\/footer>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u3001\u9ad8\u6e29\u306e\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306b\u5fc5\u8981\u4ee5\u4e0a\u306e\u91cf\u3092\u6ce8\u5165\u3057\u3066\u3057\u307e\u3046\u30b1\u30fc\u30b9\u304c\u3088\u304f\u898b\u3089\u308c\u307e\u3059\u3002 \u6ce8\u5165\u91cf\u304c\u591a\u3059\u304e\u308b\u3068\u3001\u6b21\u306e\u3088\u3046\u306a\u554f\u984c\u304c\u751f\u3058\u307e\u3059\u3002 \u518d\u73fe\u6027\u306e\u4f4e\u4e0b\uff08\u30d4\u30fc\u30af\u9762\u7a4d\u306e\u3070\u3089\u3064\u304d\uff09 \u6ce8\u5165\u30b7\u30b9\u30c6\u30e0\u306e\u52a3\u5316\u30fb\u6c5a\u67d3 \u300c\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u300d\u306e\u767a\u751f \u2192 \u5f8c\u7d9a\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306b\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u304c\u9577\u671f\u9593\u73fe\u308c\u308b\u3053\u3068\u304c\u3042\u308b \u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u304c\u8d77\u304d\u308b\u4ed5\u7d44\u307f\u306f\u6b21\u306e\u3068\u304a\u308a\u3067\u3059\u3002 \u6c17\u5316\u3057\u305f\u969b\u306b\u4f53\u7a4d\u304c\u81a8\u5f35\u3057\u3059\u304e\u305f\u84b8\u6c17\u304c\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u30e9\u30a4\u30f3\uff08\u88c5\u7f6e\u306b\u3088\u3063\u3066\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u30e9\u30a4\u30f3\uff09\u3078\u9006\u6d41\u3057\u3001\u30d5\u30a3\u30eb\u30bf\u30fc\u5185\u3067\u84c4\u7a4d\u3059\u308b \u3053\u306e\u30d5\u30a3\u30eb\u30bf\u30fc\u306f\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u969b\u306b\u5b9a\u671f\u7684\u306b\u4ea4\u63db\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b \u84c4\u7a4d\u3057\u305f\u6210\u5206\u306f\u3001\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306e\u7a2e\u985e\u30fb\u6d41\u91cf\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u6761\u4ef6\u306b\u5fdc\u3058\u3066\u5c11\u3057\u305a\u3064\u8131\u96e2\u3059\u308b \u8131\u96e2\u3057\u305f\u6210\u5206\u306f\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u3092\u7d4c\u3066\u30ab\u30e9\u30e0\u3078\u904b\u3070\u308c\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4e0a\u306b\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u3068\u3057\u3066\u73fe\u308c\u308b \u306a\u304a\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u3092\u9589\u3058\u305f\u72b6\u614b\u3067\u6c17\u5316\u3092\u884c\u3046\u305f\u3081\u84b8\u6c17\u306e\u9003\u3052\u5834\u304c\u5c11\u306a\u304f\u3001\u6ce8\u5165\u91cf\u304c\u904e\u5270\u306b\u306a\u308b\u3068\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3088\u308a\u3082\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u304c\u8d77\u304d\u3084\u3059\u304f\u306a\u308a\u307e\u3059\u3002 \u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u304a\u3051\u308b\u9069\u5207\u306a\u6ce8\u5165\u91cf\u306e\u6c7a\u3081\u65b9 \u9069\u5207\u306a\u6ce8\u5165\u91cf\u3092\u6c7a\u3081\u308b\u3046\u3048\u3067\u6700\u3082\u91cd\u8981\u306a\u306e\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u53e3\u3067\u6025\u6fc0\u306b\u84b8\u767a\u3057\u305f\u969b\u306e\u6c17\u5316\u91cf\uff08\u30b5\u30f3\u30d7\u30eb\u306e\u81a8\u5f35\u4f53\u7a4d\uff09\u3067\u3059\u3002\u3053\u306e\u6c17\u5316\u91cf\u304c\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5bb9\u7a4d\u3092\u8d85\u3048\u308b\u3068\u3001\u30ac\u30b9\u304c\u30e9\u30a4\u30ca\u30fc\u304b\u3089\u3042\u3075\u308c\u51fa\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30e9\u30a4\u30ca\u30fc\u306b\u306f\u3001\u6c17\u5316\u306b\u3088\u3063\u3066\u751f\u3058\u308b\u30ac\u30b9\u306e\u4f53\u7a4d\u3092\u4f59\u88d5\u3092\u3082\u3063\u3066\u53ce\u5bb9\u3067\u304d\u308b\u3060\u3051\u306e\u5927\u304d\u3055\u304c\u5fc5\u8981\u3067\u3059\u3002 \u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u304a\u3051\u308b\u6700\u5927\u6ce8\u5165\u91cf\u306f\u3001\u4e3b\u306b\u6b21\u306e3\u70b9\u306b\u3088\u3063\u3066\u6c7a\u307e\u308a\u307e\u3059\u3002 1. \u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5bb9\u7a4d \u30e9\u30a4\u30ca\u30fc\u306b\u304f\u3073\u308c\uff08\u30c6\u30fc\u30d1\u30fc\u3092\u542b\u3080\u7d5e\u308a\u69cb\u9020\uff09\u3084\u5145\u586b\u7269\uff08\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u306a\u3069\uff09\u304c\u3042\u308b\u3068\u3001\u305d\u306e\u5206\u3001\u6c17\u5316\u3057\u305f\u30ac\u30b9\u3092\u53ce\u5bb9\u3067\u304d\u308b\u5bb9\u7a4d\u304c\u5c0f\u3055\u304f\u306a\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u4e2d\u306f\u3082\u3068\u3082\u3068\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3067\u6e80\u305f\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u6c17\u5316\u3057\u305f\u30ac\u30b9\u3092\u5b9f\u969b\u306b\u53ce\u5bb9\u3067\u304d\u308b\u5bb9\u7a4d\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5bb9\u7a4d\u306e\u8868\u793a\u3088\u308a\u3082\u3055\u3089\u306b\u5c0f\u3055\u304f\u306a\u308b\u3001\u3068\u3044\u3046\u70b9\u3082\u8e0f\u307e\u3048\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 2. \u4f7f\u7528\u3059\u308b\u6eb6\u5a92 \u6eb6\u5a92\u304c\u7570\u306a\u308c\u3070\u3001\u6c17\u5316\u91cf\u3082\u5927\u304d\u304f\u5909\u308f\u308a\u307e\u3059\u3002\u76ee\u5b89\u3068\u3057\u3066\u306f\u3001\u6eb6\u5a92\u306e\u6975\u6027\u304c\u9ad8\u3044\u307b\u3069\u6c17\u5316\u91cf\u306f\u5927\u304d\u304f\u306a\u308a\u3001\u306a\u304b\u3067\u3082\u6c34\u306e\u6c17\u5316\u91cf\u304c\u6700\u3082\u5927\u304d\u304f\u306a\u308a\u307e\u3059\u3002 3. \u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u6e29\u5ea6\u3068\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u5727 \u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u6e29\u5ea6\u304c\u9ad8\u3044\u307b\u3069\u3001\u307e\u305f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u5727\u304c\u4f4e\u3044\u307b\u3069\u3001\u6c17\u5316\u91cf\u306f\u5927\u304d\u304f\u306a\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u540c\u3058\u6eb6\u5a92\u30fb\u540c\u3058\u6ce8\u5165\u91cf\u3067\u3082\u3001\u88c5\u7f6e\u306e\u8a2d\u5b9a\u6b21\u7b2c\u3067\u300c\u30e9\u30a4\u30ca\u30fc\u306b\u53ce\u307e\u308b\u304b\u3069\u3046\u304b\u300d\u304c\u5909\u308f\u3063\u3066\u304f\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002 \u4ee5\u4e0b\u306f\u30011 \u00b5L\u306e\u5404\u7a2e\u6eb6\u5a92\u3092250\u00b0C\u3067\u84b8\u767a\u3055\u305b\u305f\u5834\u5408\u306e\u6c17\u5316\u91cf\uff08\u00b5L\uff09\u3092\u3001\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u5727\u529b\u5225\u306b\u793a\u3057\u305f\u4f8b\u3067\u3059\u3002 \u5404\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u5727\u529b\u306b\u304a\u3051\u308b\u6c17\u5316\u91cf\uff08\u00b5L\uff09 \u6eb6\u5a92 \u5bc6\u5ea6(g\/mL) \u5206\u5b50\u91cf(MW) 5 psig 10 psig 15 psig \u30d8\u30d7\u30bf\u30f3 0.68 100 219 174 145 \u30d8\u30ad\u30b5\u30f3 0.66 86 245 224 186 \u30c8\u30eb\u30a8\u30f3 0.87 92 303 242 201&#8230;<\/p>\n","protected":false},"author":58,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2792,2800],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[613],"class_list":["post-97829","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-calculators","tag-topaz-liners"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2792,"label":"Calculators"},{"value":2800,"label":"Topaz Liners"}]},"featured_image_src_large":false,"author_info":{"display_name":"Ute Beyer","author_link":"https:\/\/discover.restek.com\/ja\/author\/ute-beyer\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2792,"name":"Calculators","slug":"calculators","term_group":0,"term_taxonomy_id":2792,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw"},{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":613,"user_id":58,"is_guest":0,"slug":"ute-beyer","display_name":"Ute Beyer","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Ute","last_name":"Beyer","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/97829","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/58"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=97829"}],"version-history":[{"count":34,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/97829\/revisions"}],"predecessor-version":[{"id":98253,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/97829\/revisions\/98253"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=97829"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=97829"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=97829"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=97829"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=97829"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=97829"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=97829"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=97829"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=97829"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}