{"id":97968,"date":"2020-10-27T14:30:00","date_gmt":"2020-10-27T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized-ja\/gc-inlet-maintenance-resteks-quick-reference-guide\/"},"modified":"2026-07-29T04:12:36","modified_gmt":"2026-07-29T04:12:36","slug":"gc-inlet-maintenance-resteks-quick-reference-guide","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss2704-ja\/gc-inlet-maintenance-resteks-quick-reference-guide","title":{"rendered":"GC\u6ce8\u5165\u53e3\u306e\u6d88\u8017\u54c1\u3001\u3044\u3064\u4ea4\u63db\u3059\u308b\uff1f\uff5c\u30e9\u30a4\u30ca\u30fc\u30fb\u30bb\u30d7\u30bf\u30e0\u30fb\u30b7\u30fc\u30eb\u306e\u9078\u3073\u65b9"},"content":{"rendered":"<div class=\"rtk-article\">\n\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">GC\u6ce8\u5165\u53e3\u306e\u30e9\u30a4\u30ca\u30fc\u30fb\u30bb\u30d7\u30bf\u30e0\u30fb\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u306f\u3001\u9078\u629e\u3092\u8aa4\u3063\u305f\u308a\u4ea4\u63db\u3092\u6020\u3063\u305f\u308a\u3059\u308b\u3060\u3051\u3067\u3001\u6d3b\u6027\u5316\u5408\u7269\u306e\u5206\u89e3\u3084\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u4f4e\u4e0b\u3001\u6700\u60aa\u306e\u5834\u5408\u306f\u76ee\u7684\u5316\u5408\u7269\u304c\u691c\u51fa\u3067\u304d\u306a\u304f\u306a\u308b\u3068\u3044\u3063\u305f\u554f\u984c\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u9069\u5207\u306a\u88fd\u54c1\u9078\u3073\u3068\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u8a2d\u8a08\u306b\u3088\u308a\u3001\u30e9\u30dc\u306e\u7a3c\u50cd\u7387\u3092\u4fdd\u3061\u306a\u304c\u3089\u6b63\u78ba\u3067\u518d\u73fe\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u3092\u78ba\u4fdd\u3067\u304d\u307e\u3059\u3002<\/p>\n<\/div>\n\n<ul>\n<li>\u9069\u5207\u306a\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u306e\u9078\u629e\u3067\u3001\u5206\u6790\u30c7\u30fc\u30bf\u306e\u54c1\u8cea\u3092\u78ba\u4fdd\u3067\u304d\u307e\u3059\u3002<\/li>\n<li>\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u3092\u7d44\u3080\u3053\u3068\u3067\u3001\u4e88\u671f\u305b\u306c\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u9632\u6b62\u3067\u304d\u307e\u3059\u3002<\/li>\n<li>\u88c5\u7f6e\u5225\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u3092\u3001\u5c02\u7528\u30da\u30fc\u30b8\u304b\u3089\u7c21\u5358\u306b\u6ce8\u6587\u3067\u304d\u307e\u3059\u3002<\/li>\n<\/ul>\n\n<p>\u30e9\u30a4\u30ca\u30fc\u3001\u30bb\u30d7\u30bf\u30e0\u3001\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u2014\u2014\u3053\u308c\u3089\u6d88\u8017\u54c1\u306e\u30b3\u30b9\u30c8\u306f\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3084\u88c5\u7f6e\u672c\u4f53\u3001\u3042\u308b\u3044\u306f\u7d0d\u671f\u9045\u5ef6\u3084\u4e0d\u6b63\u78ba\u306a\u30c7\u30fc\u30bf\u306b\u3088\u3063\u3066\u9867\u5ba2\u3092\u5931\u3046\u640d\u5931\u3068\u6bd4\u3079\u308c\u3070\u3054\u304f\u308f\u305a\u304b\u3067\u3059\u3002\u3057\u304b\u3057\u5206\u6790\u306b\u4e0e\u3048\u308b\u5f71\u97ff\u306f\u6c7a\u3057\u3066\u5c0f\u3055\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u6d3b\u6027\u5316\u5408\u7269\u306e\u5206\u89e3\u3001\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u4f4e\u4e0b\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u6027\u80fd\u554f\u984c\u306b\u3064\u306a\u304c\u308a\u3001\u6975\u7aef\u306a\u4f8b\u3067\u306f\u3001\u6ce8\u5165\u53e3\u95a2\u9023\u88fd\u54c1\u306e\u9078\u629e\u30df\u30b9\u3084\u4e0d\u5341\u5206\u306a\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u3001\u76ee\u7684\u5316\u5408\u7269\u306e\u691c\u51fa\u53ef\u5426\u3092\u5de6\u53f3\u3059\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n<p>\u9069\u5207\u306aGC\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u3092\u9078\u3073\u3001\u6b63\u3057\u3044\u624b\u9806\u3067\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u884c\u3048\u3070\u3001GC\u6ce8\u5165\u53e3\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306f\u30e9\u30a4\u30ca\u30fc\uff08\u304a\u3088\u3073\u3044\u304f\u3064\u304b\u306e\u90e8\u54c1\uff09\u306e\u4ea4\u63db\u3068\u540c\u3058\u304f\u3089\u3044\u30b7\u30f3\u30d7\u30eb\u3067\u3059\u3002\u30e9\u30dc\u306e\u7a3c\u50cd\u7387\u3092\u6700\u5927\u9650\u306b\u4fdd\u3061\u306a\u304c\u3089\u3001\u6b63\u78ba\u3067\u518d\u73fe\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u3092\u78ba\u4fdd\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>\n.rtk-article { line-height: 1.8; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 16px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n<\/style>\n\n<h2>GC\u6ce8\u5165\u53e3\u306e\u6d88\u8017\u54c1\u306f\u3069\u3046\u9078\u3076\uff1f\uff5c\u30e9\u30a4\u30ca\u30fc\u30fb\u30bb\u30d7\u30bf\u30e0\u30fb\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u306e\u9078\u3073\u65b9<\/h2>\n<p>\u6ce8\u5165\u53e3\u304c\u6c5a\u308c\u3066\u3044\u308b\u3068\u30c7\u30fc\u30bf\u54c1\u8cea\u306b\u5f71\u97ff\u3057\u307e\u3059\u304c\u3001\u30e9\u30a4\u30ca\u30fc\u3084\u30bb\u30d7\u30bf\u30e0\u306e\u9078\u629e\u30df\u30b9\u3067\u3082\u540c\u3058\u3053\u3068\u304c\u8d77\u3053\u308a\u307e\u3059\u3002GC\u6ce8\u5165\u53e3\u306e\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u65b9\u6cd5\u3084\u30bf\u30a4\u30df\u30f3\u30b0\u3092\u691c\u8a0e\u3059\u308b\u524d\u306b\u3001\u307e\u305a\u9069\u5207\u306aGC\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u304b\u3092\u78ba\u8a8d\u3059\u3079\u304d\u3067\u3059\u3002GC\u306e\u7d4c\u9a13\u304c\u8c4a\u5bcc\u306a\u5206\u6790\u8005\u3067\u3082\u3001\u3053\u306e\u78ba\u8a8d\u3092\u6020\u3089\u306a\u3044\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n<h3>\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\uff5c\u7a2e\u985e\u3068\u9078\u3073\u65b9\u306e\u57fa\u672c<\/h3>\n<p>GC\u306b\u304a\u3044\u3066\u3001\u6ce8\u5165\u53e3\u306f\u30b5\u30f3\u30d7\u30eb\u304c\u6700\u521d\u306b\u63a5\u89e6\u3059\u308b\u90e8\u5206\u3067\u3059\u3002\u9069\u5207\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u3076\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6c17\u5316\u3092\u4fc3\u9032\u3057\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u30ed\u30b9\u306e\u306a\u3044\u52b9\u7387\u7684\u306a\u79fb\u9001\u3092\u5b9f\u73fe\u3057\u3001\u30ab\u30e9\u30e0\u3092\u6c5a\u67d3\u304b\u3089\u4fdd\u8b77\u3067\u304d\u307e\u3059\u3002\u6b63\u78ba\u3067\u7cbe\u5bc6\u306a\u30c7\u30fc\u30bf\u3092\u78ba\u4fdd\u3059\u308b\u3046\u3048\u3067\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u306f\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u3002<\/p>\n<p>\u30e9\u30a4\u30ca\u30fc\u306f\u5f62\u72b6\u30fb\u5bb9\u7a4d\u30fb\u57fa\u6750\u30fb\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u30fb\u5145\u586b\u7269\u306b\u3088\u3063\u3066\u88fd\u54c1\u4ed5\u69d8\u3092\u5206\u985e\u3067\u304d\u307e\u3059\u304c\u3001\u6ce8\u5165\u65b9\u5f0f\u3067\u7d5e\u308a\u8fbc\u3080\u3053\u3068\u3067\u9078\u629e\u3092\u5927\u5e45\u306b\u7c21\u7565\u5316\u3067\u304d\u307e\u3059\u3002\u4ee5\u4e0b\u306f\u5404\u5206\u6790\u306e\u521d\u671f\u9078\u629e\u3068\u3057\u3066\u6700\u9069\u306a\u5019\u88dc\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u3084\u30e1\u30bd\u30c3\u30c9\u306b\u3088\u3063\u3066\u306f\u3001\u5225\u306e\u30e9\u30a4\u30ca\u30fc\u304c\u9069\u5207\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\uff1aTopaz Precision split liner\uff08\u30a6\u30fc\u30eb\u5165\u308a\uff09<\/li>\n<li>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\uff1aTopaz single taper liner\uff08\u30a6\u30fc\u30eb\u5165\u308a\uff09<\/li>\n<li>\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165\uff1a\n<ul>\n<li>\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u3001\u307e\u305f\u306f\u30c6\u30fc\u30ea\u30f3\u30b0\u3059\u308b\u6eb6\u5a92\u30d4\u30fc\u30af\u306e\u5f71\u97ff\u3092\u53d7\u3051\u308b\u5316\u5408\u7269\uff1a\u7a74\u304c\u4e0b\u90e8\u306b\u3042\u308bTopaz Uniliner liner<\/li>\n<li>\u6c34\u6eb6\u6db2\u6ce8\u5165\u3001\u307e\u305f\u306f\u6eb6\u5a92\u30d4\u30fc\u30af\u304b\u3089\u96e2\u308c\u305f\u4f4d\u7f6e\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\uff1a\u7a74\u304c\u4e0a\u90e8\u306b\u3042\u308bTopaz Uniliner liner<\/li>\n<\/ul>\n<\/li>\n<li>\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u6ce8\u5165\u306b\u3088\u308b\u30ac\u30b9\u30b5\u30f3\u30d7\u30eb\uff1aTopaz straight liner\uff08\u5185\u5f841.0 mm\uff09<\/li>\n<li>PTV\u6ce8\u5165\uff1a\u5c0f\u5185\u5f84\u304b\u3064\u30d0\u30c3\u30d5\u30eb\u307e\u305f\u306f\u30c7\u30a3\u30f3\u30d7\u30eb\u3092\u5c11\u306a\u304f\u3068\u30821\u3064\u5099\u3048\u305f\u3001\u88c5\u7f6e\u5c02\u7528Topaz liner<\/li>\n<\/ul>\n<p>\u30e9\u30a4\u30ca\u30fc\u9078\u629e\u306e\u8a73\u7d30\u306f<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar1991-ja\/japanese-how-to-choose-a-gc-inlet-liner\" target=\"_blank\" rel=\"noopener\">\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u65b9\uff1a\u6ce8\u5165\u65b9\u6cd5\u5225\u306e\u7c21\u5358\u306a\u30bb\u30ec\u30af\u30b7\u30e7\u30f3\u30ac\u30a4\u30c9<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<h3>\u30bb\u30d7\u30bf\u30e0\uff5c\u9078\u3073\u65b9\u306e\u30dd\u30a4\u30f3\u30c8<\/h3>\n<p>\u30bb\u30d7\u30bf\u30e0\u306e\u9078\u629e\u306f\u30e9\u30a4\u30ca\u30fc\u4ee5\u4e0a\u306b\u30b7\u30f3\u30d7\u30eb\u3067\u3059\u3002\u30bb\u30d7\u30bf\u30e0\u30d6\u30ea\u30fc\u30c9\u3084\u30b3\u30a2\u30ea\u30f3\u30b0\uff08\u30ab\u30e9\u30e0\u3068\u30c7\u30fc\u30bf\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u306e\u539f\u56e0\uff09\u3092\u9632\u3050\u305f\u3081\u306b\u8a2d\u8a08\u3055\u308c\u305f\u3001\u8907\u6570\u306e\u30aa\u30d7\u30b7\u30e7\u30f3\u304c\u7528\u610f\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<ul>\n<li>350 \u2103\u4ee5\u4e0b\u3067\u306e\u4f7f\u7528*\uff1aThermolite Plus \u30bb\u30d7\u30bf\u30e0<\/li>\n<li>400 \u2103\u4ee5\u4e0b\u3067\u306e\u4f7f\u7528*\uff1aPremium Non-Stick BTO \u30bb\u30d7\u30bf\u30e0<\/li>\n<li>\u30b3\u30a2\u30ea\u30f3\u30b0\u304c\u554f\u984c\u3068\u306a\u308b\u5834\u5408\uff08\u4e0d\u8981\u306a\u6d3b\u6027\u3092\u751f\u3058\u3055\u305b\u308b\u5834\u5408\uff09\uff1aCenterGuide \u30c7\u30a3\u30f3\u30d7\u30eb\u4ed8\u304d Thermolite Plus \u307e\u305f\u306f Premium Non-Stick BTO \u30bb\u30d7\u30bf\u30e0\u3001\u3042\u308b\u3044\u306f Merlin Microseal \u30bb\u30d7\u30bf\u30e0<\/li>\n<\/ul>\n<p>\u30bb\u30d7\u30bf\u30e0\u306e\u88fd\u54c1\u4e00\u89a7\u306f<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1219?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>*\u6ce8\u5165\u53e3\u5f84\u304c17 mm\u306e\u5834\u5408\u3001Thermolite Plus\u30bb\u30d7\u30bf\u30e0\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306f300 \u2103\u3001BTO\u30bb\u30d7\u30bf\u30e0\u306f330 \u2103\u3067\u3059\u3002\u3059\u3079\u3066\u306e\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306b\u304a\u3044\u3066\u3001BTO\u30bb\u30d7\u30bf\u30e0\u306e\u63a8\u5968\u6700\u4f4e\u52d5\u4f5c\u6e29\u5ea6\u306f250 \u2103\u3067\u3059\u3002<\/p>\n<div class=\"rtk-callout\">\n<p>\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3084\u30bb\u30d7\u30bf\u30e0\u304c\u71b1\u3044\u3068\u304d\u306f\u7d20\u624b\u3067\u89e6\u308c\u305a\u3001The Claw\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/26261\" target=\"_blank\" rel=\"noopener\">cat.# <!-- TODO: \u88fd\u54c1\u30da\u30fc\u30b8URL\u3092\u8a2d\u5b9a -->26261<\/a>\uff09\u3092\u4f7f\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u30e9\u30a4\u30ca\u30fc\u3001O\u30ea\u30f3\u30b0\u3001\u305d\u306e\u4ed6\u306e\u90e8\u54c1\u3092\u71b1\u3044\u72b6\u614b\u306e\u307e\u307e\u5b89\u5168\u304b\u3064\u6e05\u6f54\u306b\u53d6\u308a\u5916\u305b\u308b\u4fbf\u5229\u306a\u30c4\u30fc\u30eb\u3067\u3059\u3002\u307e\u305f\u3001\u3084\u3051\u3069\u305b\u305a\u306b\u7c21\u5358\u306b\u30e9\u30a4\u30ca\u30fc\u3092\u53d6\u308a\u5916\u305b\u308b\u3001Inlet Liner Removal Tool\uff08\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u53d6\u308a\u5916\u3057\u30c4\u30fc\u30eb\uff09\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20181\" target=\"_blank\" rel=\"noopener\">cat.# <!-- TODO: \u88fd\u54c1\u30da\u30fc\u30b8URL\u3092\u8a2d\u5b9a -->20181<\/a>\uff09\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n<h3>\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\uff5c\u9078\u3073\u65b9\u306e\u8003\u3048\u65b9<\/h3>\n<p>\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u306f\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u3088\u308a\u3082\u4f7f\u3044\u3084\u3059\u3055\u3084\u597d\u307f\u3092\u512a\u5148\u3057\u3066\u3088\u3044\u90e8\u54c1\u3067\u3059\u3002<\/p>\n<p>\u305f\u3060\u3057\u3001\u611f\u5ea6\u304c\u6c42\u3081\u3089\u308c\u308b\u5206\u6790\u3084\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u5206\u6790\u3067\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u30d9\u30a2\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc\u3092\u907f\u3051\u3001\u9ad8\u4e0d\u6d3b\u6027\u5ea6\u306e\u30b4\u30fc\u30eb\u30c9\u30d7\u30ec\u30fc\u30c8\u30b7\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u6d3b\u6027\u5316\u5408\u7269\u306e\u5206\u89e3\u3068\u5438\u7740\u3092\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u30ef\u30c3\u30b7\u30e3\u30fc\u30ec\u30b9\u3067\u53d6\u308a\u4ed8\u3051\u3089\u308c\u308b\u3001\u91d1\u30e1\u30c3\u30ad\u4ed5\u4e0a\u3052\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u304c\u8907\u6570\u30e9\u30a4\u30f3\u30ca\u30c3\u30d7\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u306a\u304b\u3067\u3082\u4eba\u6c17\u306eDual Vespel\u30ea\u30f3\u30b0\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u306f\u3001\u7279\u8a31\u53d6\u5f97\u6e08\u307f\u306e\u8a2d\u8a08\u3067\u4e0a\u4e0b\u4e21\u9762\u306b\u30bd\u30d5\u30c8\u306aVespel\u30ea\u30f3\u30b0\u3092\u57cb\u3081\u8fbc\u3093\u3067\u304a\u308a\u3001\u7e70\u308a\u8fd4\u3057\u306e\u71b1\u8ca0\u8377\u306b\u3082\u8010\u3048\u306a\u304c\u3089\u3001\u4f4e\u30c8\u30eb\u30af\u3067\u78ba\u5b9f\u306a\u30b7\u30fc\u30eb\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n<div class=\"rtk-callout\">\n<p>GC\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u306e\u9078\u629e\u3084GC\u6ce8\u5165\u53e3\u306e\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u3064\u3044\u3066\u3055\u3089\u306b\u8a73\u3057\u3044\u30a2\u30c9\u30d0\u30a4\u30b9\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/contact-us\" target=\"_blank\" rel=\"noopener\"><!-- TODO: \u30ea\u30f3\u30af\u5148URL\u3092\u8a2d\u5b9a -->Restek Technical Service<\/a>\u307e\u305f\u306f<a href=\"https:\/\/discover.restek.com\/find-your-sales-rep\/\" target=\"_blank\" rel=\"noopener\"><!-- TODO: \u30ea\u30f3\u30af\u5148URL\u3092\u8a2d\u5b9a -->local Restek representative<\/a>\u62c5\u5f53\u8005\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<\/div>\n<h2>\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u306f\u3069\u3046\u6c7a\u3081\u308b\uff1f\uff5cGC\u6ce8\u5165\u53e3\u306e\u4ea4\u63db\u8a08\u753b\u306e\u7acb\u3066\u65b9<\/h2>\n<p>\u9069\u5207\u306aGC\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3067\u304d\u305f\u3089\u3001\u6b21\u306fGC\u6ce8\u5165\u53e3\u306e\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u3092\u691c\u8a0e\u3057\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u4e00\u5f8b\u306e\u3001\u30e9\u30a4\u30ca\u30fc\u30fb\u30bb\u30d7\u30bf\u30e0\u30fb\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u306e\u4ea4\u63db\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u3092\u63a8\u5968\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u74b0\u5883\u8a66\u9a13\u3068\u3044\u3046\u4e00\u3064\u306e\u5206\u91ce\u3060\u3051\u3067\u3082\u3001\u30b5\u30f3\u30d7\u30eb\u3001\u6ce8\u5165\u6280\u8853\u3001\u88c5\u7f6e\u3001\u691c\u51fa\u5668\u306a\u3069\u3001\u5206\u6790\u6761\u4ef6\u304c\u591a\u5c90\u306b\u308f\u305f\u308b\u305f\u3081\u3067\u3059\u3002\u77f3\u6cb9\u5316\u5b66\u3001\u98df\u54c1\u5b89\u5168\u3001\u81e8\u5e8a\u8a3a\u65ad\u306a\u3069\u4ed6\u306e\u5206\u91ce\u3082\u52a0\u308f\u308c\u3070\u306a\u304a\u3055\u3089\u3067\u3059\u3002\u7279\u306b\u6c5a\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u3059\u308b\u5834\u5408\u306f1\u65e52\u56de\u306e\u4ea4\u63db\u304c\u5fc5\u8981\u306a\u3053\u3068\u3082\u3042\u308c\u3070\u3001\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9GC\u3067\u306f\u5e741\u56de\u3067\u5341\u5206\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u306f\u3001\u5206\u6790\u3054\u3068\u306b\u500b\u5225\u306b\u6c7a\u3081\u308b\u3079\u304d\u3067\u3057\u3087\u3046\u3002<\/p>\n<p>\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u3092\u8a2d\u5b9a\u3059\u308b\u969b\u306e\u30dd\u30a4\u30f3\u30c8\u306f\u3001\u554f\u984c\u304c\u767a\u751f\u3059\u308b\u524d\u306b\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u3092\u4ea4\u63db\u3059\u308b\u3068\u3044\u3046\u8003\u3048\u65b9\u3067\u3059\u3002\u3053\u308c\u3092\u5b9f\u8df5\u3059\u308b\u3053\u3068\u3067\u3001\u30e9\u30dc\u306e\u7a3c\u50cd\u306b\u5f71\u97ff\u306e\u5c11\u306a\u3044\u6642\u9593\u5e2f\u3092\u9078\u3093\u3067\u5bfe\u5fdc\u3067\u304d\u3001\u30c8\u30e9\u30d6\u30eb\u5bfe\u5fdc\u306b\u9577\u6642\u9593\u3092\u8cbb\u3084\u3059\u3053\u3068\u3082\u7d0d\u671f\u9045\u5ef6\u3082\u9632\u3052\u307e\u3059\u3002<\/p>\n<p>\u5177\u4f53\u7684\u306b\u306f\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u5b9f\u65bd\u3057\u3066\u304b\u3089\u6ce8\u5165\u53e3\u306e\u6c5a\u308c\u3084\u52a3\u5316\u304c\u539f\u56e0\u3067\u30c7\u30fc\u30bf\u306b\u554f\u984c\u304c\u751f\u3058\u59cb\u3081\u308b\u307e\u3067\u306e\u671f\u9593\u3092\u628a\u63e1\u3057\u3066\u304a\u304d\u3001\u554f\u984c\u304c\u751f\u3058\u308b<strong>\u524d\u306b<\/strong>\u5bfe\u5fdc\u3067\u304d\u308b\u3088\u3046\u306a\u4ea4\u63db\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u3092\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u304c\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u3002<\/p>\n<h3>\u30c7\u30fc\u30bf\u306b\u73fe\u308c\u308bGC\u6ce8\u5165\u53e3\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u30b5\u30a4\u30f3<\/h3>\n<p>\u6b21\u306e\u3088\u3046\u306a\u30b7\u30b0\u30ca\u30eb\u304c\u78ba\u8a8d\u3055\u308c\u305f\u5834\u5408\u306f\u3001GC\u6ce8\u5165\u53e3\u306e\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u5fc5\u8981\u306a\u30b5\u30a4\u30f3\u3067\u3059\u3002<\/p>\n<ul>\n<li>\u30b7\u30b0\u30ca\u30eb\u306e\u4f4e\u4e0b\u30fb\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u640d\u5931\uff1a\u6ce8\u5165\u53e3\u306e\u6d3b\u6027\uff08\u8868\u9762\u6d3b\u6027\uff09\u3001\u6ce8\u5165\u53e3\u3067\u306e\u30c7\u30a3\u30b9\u30af\u30ea\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3001\u6ce8\u5165\u53e3\u306e\u30ea\u30fc\u30af\uff08\u30bb\u30d7\u30bf\u30e0\u5468\u8fba\u306e\u30b7\u30fc\u30eb\u3001O\u30ea\u30f3\u30b0\u3001\u30d5\u30a7\u30e9\u30eb\u306a\u3069\uff09<\/li>\n<li>\u7570\u5e38\u30b7\u30b0\u30ca\u30eb\uff1a\u6c5a\u67d3\uff08O\u30ea\u30f3\u30b0\u306e\u30d6\u30ea\u30fc\u30c9\u3001\u30e9\u30a4\u30ca\u30fc\u5185\u3078\u306e\u30bb\u30d7\u30bf\u30e0\u7c92\u5b50\u306e\u6df7\u5165\u3001\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u84c4\u7a4d\u3014\u30a2\u30a6\u30c8\u30ac\u30b9\u3015\uff09\u3001\u6ce8\u5165\u53e3\u306e\u6d3b\u6027\uff08\u8868\u9762\u6d3b\u6027\uff09\u306b\u3088\u308b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u5206\u89e3\u3067\u751f\u3058\u308b\u65b0\u305f\u306a\u5316\u5408\u7269\uff08\u30a8\u30ad\u30b9\u30c8\u30e9\u30d4\u30fc\u30af\uff09<\/li>\n<li>\u30b7\u30b0\u30ca\u30eb\u306e\u6b6a\u307f\u30fb\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\uff08\u30c6\u30fc\u30ea\u30f3\u30b0\u306a\u3069\uff09\uff1a\u6ce8\u5165\u53e3\u306e\u6d3b\u6027\uff08\u8868\u9762\u6d3b\u6027\uff09\u3001\u6ce8\u5165\u53e3\u306e\u30ea\u30fc\u30af\uff08\u30bb\u30d7\u30bf\u30e0\u5468\u8fba\u306e\u30b7\u30fc\u30eb\u3001O\u30ea\u30f3\u30b0\u3001\u30d5\u30a7\u30e9\u30eb\u306a\u3069\uff09<\/li>\n<\/ul>\n<p>\u4ea4\u63db\u90e8\u54c1\u3092\u4e8b\u524d\u306b\u624b\u914d\u3057\u3066\u304a\u304f\u3053\u3068\u3082\u91cd\u8981\u3067\u3059\u3002GC\u6ce8\u5165\u53e3\u306e\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u969b\u306f\u3001\u30bb\u30d7\u30bf\u30e0\u3001\u30e9\u30a4\u30ca\u30fc\u3001O\u30ea\u30f3\u30b0\u3001\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u3092\u307e\u3068\u3081\u3066\u4ea4\u63db\u3059\u308b\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u6c17\u3065\u304b\u306a\u3044\u3046\u3061\u306b\u8907\u6570\u306e\u90e8\u54c1\u304c\u540c\u6642\u306b\u52a3\u5316\u3057\u3066\u3044\u308b\u5834\u5408\u3082\u3042\u308b\u305f\u3081\u3067\u3059\u3002\u5404\u90e8\u54c1\u306e\u30b3\u30b9\u30c8\u306f\u3001\u4e0d\u8981\u306a\u88c5\u7f6e\u505c\u6b62\u3068\u6bd4\u3079\u308c\u3070\u3054\u304f\u308f\u305a\u304b\u3067\u3059\u3002<\/p>\n<h2>\u30ea\u30fc\u30af\u306e\u306a\u3044\u30b7\u30b9\u30c6\u30e0\u3092\u7dad\u6301\u3059\u308b\uff5c\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u306e\u6d3b\u7528<\/h2>\n<p>\u9ad8\u54c1\u8cea\u306a\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u2014\u2014Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/28500\" target=\"_blank\" rel=\"noopener\">cat.# <!-- TODO: \u88fd\u54c1\u30da\u30fc\u30b8URL\u3092\u8a2d\u5b9a -->28500<\/a>\uff09\u306a\u3069\u2014\u2014\u306f\u3059\u3079\u3066\u306eGC\u30e9\u30dc\u306b\u6b20\u304b\u305b\u307e\u305b\u3093\u3002\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4ed8\u3051\u305f\u308a\u3001GC\u6ce8\u5165\u53e3\u306e\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u5b9f\u65bd\u3057\u305f\u308a\u3057\u305f\u5f8c\u306f\u3001\u5fc5\u305a\u30ea\u30fc\u30af\u691c\u67fb\u3092\u884c\u3063\u3066\u304b\u3089\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3084\u5206\u6790\u3092\u958b\u59cb\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ab\u30e9\u30e0\u3084\u691c\u51fa\u5668\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u672a\u7136\u306b\u9632\u304e\u3001\u5f8c\u306e\u30c8\u30e9\u30d6\u30eb\u5bfe\u5fdc\u306b\u304b\u304b\u308b\u6642\u9593\u3092\u5927\u5e45\u306b\u524a\u6e1b\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u9069\u5207\u306a\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u3068\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3067\u3001\u5b89\u5b9a\u3057\u305f\u30c7\u30fc\u30bf\u54c1\u8cea\u3092\u78ba\u4fdd\u3059\u308b<\/h2>\n<p>Restek Topaz\u30e9\u30a4\u30ca\u30fc\u3001\u30bb\u30d7\u30bf\u30e0\u3001\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u3092\u306f\u3058\u3081\u3068\u3059\u308bGC\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u3092\u6b63\u3057\u304f\u9078\u629e\u3057\u3001\u9069\u5207\u306a\u30bf\u30a4\u30df\u30f3\u30b0\u3067\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u5b9f\u8df5\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u6790\u6027\u80fd\u306e\u6700\u5927\u5316\u3001\u518d\u73fe\u6027\u306e\u5411\u4e0a\u3001\u305d\u3057\u3066\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306e\u524a\u6e1b\u3092\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u5fc5\u8981\u306a\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u306f<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1111?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089\u306e\u30da\u30fc\u30b8<\/a>\u304b\u3089\u3054\u78ba\u8a8d\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<details class=\"rtk-faq\">\n<h3>GC\u6ce8\u5165\u53e3\u306e\u30e9\u30a4\u30ca\u30fc\u306f\u3069\u3046\u3084\u3063\u3066\u9078\u3079\u3070\u3088\u3044\u3067\u3059\u304b\uff1f<\/h3>\n<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u30fb\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165\u30fb\u30ac\u30b9\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u30fbPTV\u6ce8\u5165\u306a\u3069\u3001\u6ce8\u5165\u65b9\u5f0f\u306b\u3088\u3063\u3066\u9069\u3057\u305f\u30e9\u30a4\u30ca\u30fc\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u307e\u305a\u6ce8\u5165\u65b9\u5f0f\u3067\u7d5e\u308a\u8fbc\u3093\u3060\u3046\u3048\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u3084\u30e1\u30bd\u30c3\u30c9\u306e\u7279\u6027\u306b\u5fdc\u3058\u3066\u6700\u7d42\u7684\u306a\u88fd\u54c1\u3092\u9078\u3076\u306e\u304c\u57fa\u672c\u306e\u8003\u3048\u65b9\u3067\u3059\u3002<\/p>\n<\/details><details class=\"rtk-faq\">\n<h3>\u30bb\u30d7\u30bf\u30e0\u306f\u3069\u3046\u9078\u3079\u3070\u3088\u3044\u3067\u3059\u304b\uff1f<\/h3>\n<p>\u4f7f\u7528\u6e29\u5ea6\u306e\u4e0a\u9650\uff08350 \u2103\u4ee5\u4e0b\u304b400 \u2103\u4ee5\u4e0b\u304b\uff09\u3068\u3001\u30b3\u30a2\u30ea\u30f3\u30b0\u306b\u3088\u308b\u4e0d\u8981\u306a\u6d3b\u6027\u304c\u554f\u984c\u306b\u306a\u308b\u304b\u3069\u3046\u304b\u3067\u9078\u3073\u307e\u3059\u3002\u30b3\u30a2\u30ea\u30f3\u30b0\u5bfe\u7b56\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001CenterGuide\u30c7\u30a3\u30f3\u30d7\u30eb\u4ed8\u304d\u30bb\u30d7\u30bf\u30e0\u3084Merlin Microseal\u30bb\u30d7\u30bf\u30e0\u304c\u5019\u88dc\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/details><details class=\"rtk-faq\">\n<h3>GC\u6ce8\u5165\u53e3\u306e\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u5fc5\u8981\u306b\u306a\u3063\u305f\u30b5\u30a4\u30f3\u306f\u4f55\u3067\u3059\u304b\uff1f<\/h3>\n<p>\u30b7\u30b0\u30ca\u30eb\u306e\u4f4e\u4e0b\u30fb\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u640d\u5931\u3001\u6c5a\u67d3\u306b\u3088\u308b\u7570\u5e38\u30b7\u30b0\u30ca\u30eb\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u306a\u3069\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u3068\u3044\u3063\u305f\u5909\u5316\u304c\u30c7\u30fc\u30bf\u306b\u73fe\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30b5\u30a4\u30f3\u304c\u898b\u3089\u308c\u305f\u3089\u3001\u6ce8\u5165\u53e3\u306e\u6d3b\u6027\u3084\u30ea\u30fc\u30af\u3001\u6c5a\u67d3\u306e\u6709\u7121\u3092\u78ba\u8a8d\u3059\u308b\u30bf\u30a4\u30df\u30f3\u30b0\u3067\u3059\u3002<\/p>\n<\/details><details class=\"rtk-faq\">\n<h3>\u4fdd\u5b88\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u306f\u3069\u306e\u304f\u3089\u3044\u306e\u983b\u5ea6\u306b\u8a2d\u5b9a\u3059\u3079\u304d\u3067\u3059\u304b\uff1f<\/h3>\n<p>\u5206\u6790\u5206\u91ce\u3084\u6761\u4ef6\u306b\u3088\u3063\u3066\u5927\u304d\u304f\u7570\u306a\u308b\u305f\u3081\u3001\u4e00\u5f8b\u306e\u983b\u5ea6\u306f\u63a8\u5968\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u6c5a\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u5206\u6790\u3067\u306f1\u65e52\u56de\u306e\u4ea4\u63db\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u3082\u3042\u308c\u3070\u3001\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9GC\u3067\u306f\u5e741\u56de\u3067\u5341\u5206\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u5f8c\u306b\u30c7\u30fc\u30bf\u3078\u554f\u984c\u304c\u751f\u3058\u59cb\u3081\u308b\u307e\u3067\u306e\u671f\u9593\u3092\u628a\u63e1\u3057\u3001\u554f\u984c\u304c\u8d77\u304d\u308b\u524d\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u30b9\u30b1\u30b8\u30e5\u30fc\u30eb\u3092\u5206\u6790\u3054\u3068\u306b\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u304c\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u3002<\/p>\n<\/details><details class=\"rtk-faq\">\n<h3>\u88c5\u7f6e\u5225\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u306f\u3069\u3053\u3067\u63a2\u305b\u307e\u3059\u304b\uff1f<\/h3>\n<p><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1111?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089\u306e\u30da\u30fc\u30b8<\/a>\u304b\u3089\u3001\u304a\u4f7f\u3044\u306e\u88c5\u7f6e\u306b\u5bfe\u5fdc\u3057\u305f\u30a4\u30f3\u30ec\u30c3\u30c8\u95a2\u9023\u88fd\u54c1\u3092\u3054\u78ba\u8a8d\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<\/details>\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26261\">                                \u30ab\u30bf\u30ed\u30b0No. 26261                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">The Claw Tool<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26261\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/20181\">                                \u30ab\u30bf\u30ed\u30b0No. 20181                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Inlet Liner Removal Tool, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/20181\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u30ab\u30bf\u30ed\u30b0No. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                \u30ab\u30bf\u30ed\u30b0No. 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22186\">                                \u30ab\u30bf\u30ed\u30b0No. 22186                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">MLE (Make Life Easier) Capillary Tool Kit, for Agilent GCs<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22186\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22181\">                                \u30ab\u30bf\u30ed\u30b0No. 22181                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Inlet Maintenance Kit, for Agilent GCs<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22181\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>With Resteks guidance and our comprehensive line of high-quality GC inlet supplies, performing proper GC inlet maintenance to help maximize your labs uptime and ensure accurate, reproducible data is as easy as replacing a liner (and a few other items).<\/p>\n","protected":false},"author":11,"featured_media":7405,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[2800],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2566,2552],"resource-technique":[2340],"ppma_author":[414,2814],"class_list":["post-97968","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-topaz-liners","product-library-inlet-supplies-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2800,"label":"Topaz Liners"}],"product-library":[{"value":2566,"label":"GC \u6ce8\u5165\u53e3\u95a2\u9023\u90e8\u54c1"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS2704-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":789,"category_count":511,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."},{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/97968","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=97968"}],"version-history":[{"count":19,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/97968\/revisions"}],"predecessor-version":[{"id":99671,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/97968\/revisions\/99671"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7405"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=97968"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=97968"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=97968"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=97968"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=97968"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=97968"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=97968"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=97968"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=97968"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}