{"id":98113,"date":"2025-08-01T13:46:55","date_gmt":"2025-08-01T13:46:55","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized-ja\/what-liner-do-i-need-for\/"},"modified":"2026-10-02T18:05:55","modified_gmt":"2026-10-02T18:05:55","slug":"what-liner-do-i-need-for","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5040-ja\/what-liner-do-i-need-for","title":{"rendered":"\u3069\u306eGC\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u3076\u3079\u304d\u304b"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u9069\u5207\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3059\u308b\u306b\u306f\u3001\u307e\u305a\u5206\u6790\u306e\u76ee\u7684\u3092\u660e\u78ba\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:18px\"><strong>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165<\/strong>\uff1a \u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306f\u3001\u6c5a\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3084\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u6fc3\u5ea6\u7bc4\u56f2\u304c\u5e83\u3044\u30b5\u30f3\u30d7\u30eb\u306b\u4e00\u822c\u7684\u306b\u7528\u3044\u3089\u308c\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u3092\u5747\u4e00\u306a\u84b8\u6c17\u30af\u30e9\u30a6\u30c9\u306b\u8fc5\u901f\u304b\u3064\u5b8c\u5168\u306b\u6c17\u5316\u3055\u305b\u308b\u305f\u3081\u3001\u3055\u307e\u3056\u307e\u306a\u30e9\u30a4\u30ca\u30fc\u8a2d\u8a08\u304c\u3042\u308a\u307e\u3059\u3002\u6700\u3082\u4e00\u822c\u7684\u306a\u306e\u306f\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30a6\u30fc\u30eb\u304c\u5145\u586b\u3055\u308c\u305f\u30b9\u30c8\u30ec\u30fc\u30c8\u30c1\u30e5\u30fc\u30d6\u3067\u3059\u3002\u305d\u306e\u307b\u304b\u306b\u3082\u3001\u30e9\u30df\u30ca\u30fc\u30ab\u30c3\u30d7\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d7\u30ea\u30c3\u30bf\u30fc\u3001\u30ab\u30c3\u30d7\u30b9\u30d7\u30ea\u30c3\u30bf\u30fc\u3001\u30b5\u30a4\u30af\u30ed\u3001\u30d0\u30c3\u30d5\u30eb\u30b9\u30d7\u30ea\u30c3\u30bf\u30fc\u3001\u30df\u30cb\u30e9\u30e0\u30b9\u30d7\u30ea\u30c3\u30bf\u30fc\u306a\u3069\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u3044\u305a\u308c\u3082\u3001\u8fc5\u901f\u3067\u5747\u4e00\u306a\u6c17\u5316\u3092\u4fc3\u9032\u3057\u3001\u518d\u73fe\u6027\u306e\u9ad8\u3044\u6027\u80fd\u3092\u767a\u63ee\u3057\u3001\u5206\u5b50\u91cf\u306e\u9055\u3044\u306b\u3088\u308b\u30c7\u30a3\u30b9\u30af\u30ea\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3088\u3046\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li style=\"font-size:18px\"><strong>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165<\/strong>\uff1a\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u3001\u4f4e\u6fc3\u5ea6\u5206\u6790\u306b\u4e00\u822c\u7684\u306b\u7528\u3044\u3089\u308c\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u306f\u30c6\u30fc\u30d1\u30fc\u8a2d\u8a08\uff08\u30b7\u30f3\u30b0\u30eb\u3001\u30c0\u30d6\u30eb\u3001\u307e\u305f\u306f\u30ea\u30bb\u30b9\u30c8\uff09\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u30c6\u30fc\u30d1\u30fc\u8a2d\u8a08\u3092\u63a1\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30db\u30fc\u30eb\u30c9\u6642\u9593\u4e2d\u306b\u84b8\u6c17\u30af\u30e9\u30a6\u30c9\u3092\u30e9\u30a4\u30ca\u30fc\u5185\u306b\u4fdd\u6301\u3057\u3001\u91d1\u5c5e\u88fd\u6ce8\u5165\u53e3\u8868\u9762\u3068\u306e\u63a5\u89e6\u306b\u3088\u308b\u6d3b\u6027\u5316\u5408\u7269\u306e\u5206\u89e3\u3092\u6291\u3048\u307e\u3059\u3002\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u8a2d\u8a08\u306f\u30b7\u30f3\u30b0\u30eb\u30ab\u30e9\u30e0\u7528\u3001\u30ea\u30bb\u30b9\u30c8\u8a2d\u8a08\u306f\u30c7\u30e5\u30a2\u30eb\u30ab\u30e9\u30e0\u7528\u306b\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u3044\u305a\u308c\u3082\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30a6\u30fc\u30eb\u304c\u5145\u586b\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li style=\"font-size:18px\"><strong>\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165<\/strong>\uff1a\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30ab\u30e9\u30e0\u3092\u6ce8\u5165\u53e3\u30b9\u30ea\u30fc\u30d6\u306e\u5e95\u90e8\u306b\u76f4\u63a5\u63a5\u7d9a\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u30b5\u30f3\u30d7\u30eb\u3092\u30ab\u30e9\u30e0\u306b\u76f4\u63a5\u9001\u308a\u8fbc\u3080\u3053\u3068\u304c\u3067\u304d\u3001\u6ce8\u5165\u53e3\u3067\u306e\u30c7\u30a3\u30b9\u30af\u30ea\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3084\u9ad8\u6e29\u306e\u91d1\u5c5e\u8868\u9762\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u63a5\u89e6\u3092\u6392\u9664\u3067\u304d\u307e\u3059\u3002\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165\u30e9\u30a4\u30ca\u30fc\u306f\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u7528\u307e\u305f\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u53e3\u7528\u304c\u7528\u610f\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b9\u30d7\u30ea\u30c3\u30c8\/\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u53e3\u306b\u306f\u30c9\u30ea\u30eb\u30c9Unilaner\u30a4\u30f3\u30ec\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u306a\u304a\u3001\u7528\u9014\u3092\u554f\u308f\u305a\u3059\u3079\u3066\u306e\u30e9\u30a4\u30ca\u30fc\u306f\u5fc5\u305a\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3092\u65bd\u3057\u305f\u3082\u306e\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u5747\u4e00\u306a\u30b5\u30f3\u30d7\u30eb\u6c17\u5316\u3092\u4fc3\u9032\u3057\u3001\u4e0d\u63ee\u767a\u6027\u6b8b\u7559\u7269\u3092\u6355\u96c6\u3057\u3066\u30ab\u30e9\u30e0\u6c5a\u67d3\u3092\u9632\u3050\u305f\u3081\u3001\u53ef\u80fd\u306a\u9650\u308a\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u306e\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u307e\u305f\u306f\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30a6\u30fc\u30eb\u5145\u586b\u54c1\u306e\u3054\u4f7f\u7528\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u9069\u5207\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3059\u308b\u306b\u306f\u3001\u307e\u305a\u5206\u6790\u306e\u76ee\u7684\u3092\u660e\u78ba\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 \u306a\u304a\u3001\u7528\u9014\u3092\u554f\u308f\u305a\u3059\u3079\u3066\u306e\u30e9\u30a4\u30ca\u30fc\u306f\u5fc5\u305a\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3092\u65bd\u3057\u305f\u3082\u306e\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u5747\u4e00\u306a\u30b5\u30f3\u30d7\u30eb\u6c17\u5316\u3092\u4fc3\u9032\u3057\u3001\u4e0d\u63ee\u767a\u6027\u6b8b\u7559\u7269\u3092\u6355\u96c6\u3057\u3066\u30ab\u30e9\u30e0\u6c5a\u67d3\u3092\u9632\u3050\u305f\u3081\u3001\u53ef\u80fd\u306a\u9650\u308a\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u306e\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u307e\u305f\u306f\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30a6\u30fc\u30eb\u5145\u586b\u54c1\u306e\u3054\u4f7f\u7528\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2796,2797,2800,2800],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814,2814],"class_list":["post-98113","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-gc-accessories","tag-faq-inlet-liners","tag-topaz-liners"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2796,"label":"FAQ: GC Accessories"},{"value":2797,"label":"FAQ: Inlet Liners"},{"value":2800,"label":"Topaz Liners"},{"value":2800,"label":"Topaz Liners"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2796,"name":"FAQ: GC Accessories","slug":"faq-gc-accessories","term_group":0,"term_taxonomy_id":2796,"taxonomy":"post_tag","description":"","parent":0,"count":22,"filter":"raw"},{"term_id":2797,"name":"FAQ: Inlet Liners","slug":"faq-inlet-liners","term_group":0,"term_taxonomy_id":2797,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw"},{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"},{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."},{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98113","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=98113"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98113\/revisions"}],"predecessor-version":[{"id":99673,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98113\/revisions\/99673"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=98113"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=98113"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=98113"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=98113"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=98113"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=98113"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=98113"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=98113"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=98113"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}