{"id":98261,"date":"2025-07-31T16:44:59","date_gmt":"2025-07-31T16:44:59","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized-ja\/are-there-recommended-gc-inlet-liner-types-for-use-with-this-seal\/"},"modified":"2026-07-29T05:54:20","modified_gmt":"2026-07-29T05:54:20","slug":"are-there-recommended-gc-inlet-liner-types-for-use-with-this-seal","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot4963-ja\/are-there-recommended-gc-inlet-liner-types-for-use-with-this-seal","title":{"rendered":"Flip Seal\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u306b\u6700\u9069\u306aGC\u30e9\u30a4\u30ca\u30fc\u306f\uff1f\uff5c\u30b9\u30d7\u30ea\u30c3\u30c8\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u5225\u304a\u3059\u3059\u3081"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u306fTopaz\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08\u5185\u5f84: 4\u339c\u3001\u30d7\u30ec\u30df\u30a2\u30e0\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u30a6\u30fc\u30eb\u5165\u308a\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23303\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23303<\/a>\uff09\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u306fTopaz\u30d7\u30ec\u30b7\u30b8\u30e7\u30f3\u30e9\u30a4\u30ca\u30fc\uff08\u5185\u5f84: 4\u339c\u3001\u30d7\u30ec\u30df\u30a2\u30e0\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u30a6\u30fc\u30eb\u5165\u308a\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23305\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23305<\/a>\uff09\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u5fb9\u5e95\u7684\u306a\u30d7\u30ec\u30df\u30a2\u30e0\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3092\u65bd\u3057\u305f\u30a6\u30fc\u30eb\u306b\u3088\u308a\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u306e\u3044\u305a\u308c\u306e\u6ce8\u5165\u306b\u304a\u3044\u3066\u3082\u30b5\u30f3\u30d7\u30eb\u304c\u5747\u4e00\u306b\u6c17\u5316\u3057\u3001\u518d\u73fe\u6027\u3068\u7cbe\u5ea6\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<br>\u307e\u305f\u3001\u30a6\u30fc\u30eb\u306f\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u4e0a\u3078\u306e\u6db2\u4f53\u30b5\u30f3\u30d7\u30eb\u306e\u4ed8\u7740\u3092\u9632\u304e\u307e\u3059\u3002\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u3067\u306f\u9ad8\u6e29\u306e\u91d1\u5c5e\u3068\u306e\u63a5\u89e6\u306b\u3088\u3063\u3066\u71b1\u611f\u53d7\u6027\u5316\u5408\u7269\u304c\u5206\u89e3\u3057\u305f\u308a\u3001\u6cb8\u70b9\u306e\u9ad8\u3044\u9ad8\u5206\u5b50\u91cf\u5316\u5408\u7269\u304c\u30ab\u30e9\u30e0\u3078\u5230\u9054\u3067\u304d\u305a\u306b\u30ed\u30b9\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30a6\u30fc\u30eb\u306f\u4e0d\u63ee\u767a\u6027\u306e\u30b5\u30f3\u30d7\u30eb\u6b8b\u7559\u7269\uff08\u300c\u6c5a\u308c\u300d\uff09\u304b\u3089GC\u30ab\u30e9\u30e0\u3092\u4fdd\u8b77\u3057\u3001\u7279\u306b\u5206\u6790\u304c\u56f0\u96e3\u306a\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u30ab\u30e9\u30e0\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3092\u9577\u304f\u7dad\u6301\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u306fTopaz\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08\u5185\u5f84: 4\u339c\u3001\u30d7\u30ec\u30df\u30a2\u30e0\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u30a6\u30fc\u30eb\u5165\u308a\u3001cat.# 23303\uff09\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u306fTopaz\u30d7\u30ec\u30b7\u30b8\u30e7\u30f3\u30e9\u30a4\u30ca\u30fc\uff08\u5185\u5f84: 4\u339c\u3001\u30d7\u30ec\u30df\u30a2\u30e0\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u30a6\u30fc\u30eb\u5165\u308a\u3001cat.# 23305\uff09\u3092\u63a8\u5968\u3057\u307e\u3059\u3002 \u5fb9\u5e95\u7684\u306a\u30d7\u30ec\u30df\u30a2\u30e0\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3092\u65bd\u3057\u305f\u30a6\u30fc\u30eb\u306b\u3088\u308a\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u306e\u3044\u305a\u308c\u306e\u6ce8\u5165\u306b\u304a\u3044\u3066\u3082\u30b5\u30f3\u30d7\u30eb\u304c\u5747\u4e00\u306b\u6c17\u5316\u3057\u3001\u518d\u73fe\u6027\u3068\u7cbe\u5ea6\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30a6\u30fc\u30eb\u306f\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u4e0a\u3078\u306e\u6db2\u4f53\u30b5\u30f3\u30d7\u30eb\u306e\u4ed8\u7740\u3092\u9632\u304e\u307e\u3059\u3002\u30a4\u30f3\u30ec\u30c3\u30c8\u30b7\u30fc\u30eb\u3067\u306f\u9ad8\u6e29\u306e\u91d1\u5c5e\u3068\u306e\u63a5\u89e6\u306b\u3088\u3063\u3066\u71b1\u611f\u53d7\u6027\u5316\u5408\u7269\u304c\u5206\u89e3\u3057\u305f\u308a\u3001\u6cb8\u70b9\u306e\u9ad8\u3044\u9ad8\u5206\u5b50\u91cf\u5316\u5408\u7269\u304c\u30ab\u30e9\u30e0\u3078\u5230\u9054\u3067\u304d\u305a\u306b\u30ed\u30b9\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30a6\u30fc\u30eb\u306f\u4e0d\u63ee\u767a\u6027\u306e\u30b5\u30f3\u30d7\u30eb\u6b8b\u7559\u7269\uff08\u300c\u6c5a\u308c\u300d\uff09\u304b\u3089GC\u30ab\u30e9\u30e0\u3092\u4fdd\u8b77\u3057\u3001\u7279\u306b\u5206\u6790\u304c\u56f0\u96e3\u306a\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u30ab\u30e9\u30e0\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3092\u9577\u304f\u7dad\u6301\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2799,2797,2800],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814,2814],"class_list":["post-98261","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-flip-seal-inlet-seals","tag-faq-inlet-liners","tag-topaz-liners"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2799,"label":"FAQ: Flip Seal Inlet Seals"},{"value":2797,"label":"FAQ: Inlet Liners"},{"value":2800,"label":"Topaz Liners"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2799,"name":"FAQ: Flip Seal Inlet Seals","slug":"faq-flip-seal-inlet-seals","term_group":0,"term_taxonomy_id":2799,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw"},{"term_id":2797,"name":"FAQ: Inlet Liners","slug":"faq-inlet-liners","term_group":0,"term_taxonomy_id":2797,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw"},{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."},{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98261","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=98261"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98261\/revisions"}],"predecessor-version":[{"id":99675,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98261\/revisions\/99675"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=98261"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=98261"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=98261"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=98261"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=98261"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=98261"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=98261"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=98261"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=98261"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}