{"id":98605,"date":"2018-09-25T04:00:00","date_gmt":"2018-09-25T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized-ja\/selecting-a-gc-inlet-liner\/"},"modified":"2026-07-28T05:39:43","modified_gmt":"2026-07-28T05:39:43","slug":"selecting-a-gc-inlet-liner","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3656-ja\/selecting-a-gc-inlet-liner","title":{"rendered":"GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u65b9\uff5c\u30b9\u30d7\u30ea\u30c3\u30c8\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u89e3\u8aac"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Selecting a GC Inlet Liner\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/40NqDKfUjP0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n<style>\n.rtk-article { line-height: 1.8; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 16px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout {\n    padding: 14px 16px;\n  }\n}\n<\/style>\n\n\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n<div class=\"rtk-article\">\n\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6db2\u4f53\u304b\u3089\u30ac\u30b9\u3078\u3068\u6c17\u5316\u3057\u3001\u30ab\u30e9\u30e0\u3078\u79fb\u9001\u3055\u308c\u308b\u5834\u6240\u3067\u3059\u3002\u3053\u306e\u6c17\u5316\u30fb\u79fb\u9001\u306e\u30d7\u30ed\u30bb\u30b9\u304c\u5b89\u5b9a\u3057\u3066\u3044\u308b\u304b\u3069\u3046\u304b\u3067\u3001\u5206\u96e2\u306e\u518d\u73fe\u6027\u305d\u306e\u3082\u306e\u304c\u6c7a\u307e\u308a\u307e\u3059\u3002\u6ce8\u5165\u65b9\u5f0f\uff08\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\uff09\u3054\u3068\u306b\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30b5\u30f3\u30d7\u30eb\u306e\u6d41\u308c\u65b9\u304c\u7570\u306a\u308b\u305f\u3081\u3001\u307e\u305a\u6ce8\u5165\u65b9\u5f0f\u3092\u57fa\u6e96\u306b\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u3092\u9078\u3076\u3053\u3068\u304c\u3001\u6700\u77ed\u306e\u9078\u3073\u65b9\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8&nbsp;<\/h2>\n\n\n<details style=\"cursor:pointer; border:1px solid #d8e3e6; border-radius:6px; margin-bottom:2em; overflow:hidden;\">\n<summary style=\"cursor:pointer; padding:14px 18px; background:#f5f9fc; list-style:none; font-weight:700;\">\u52d5\u753b\u306e\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8\u3092\u8868\u793a<\/summary>\n<div style=\"padding:4px 18px 18px;\">\n<p>Restek Tip\u3078\u3088\u3046\u3053\u305d\u3002\u4eca\u56de\u304a\u8a71\u3057\u3059\u308b\u306e\u306f\u3001\u79c1\u304c\u30e9\u30a4\u30ca\u30fc\u71b1\u3092\u50be\u3051\u308bGC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306b\u3064\u3044\u3066\u3067\u3059\u3002\u3053\u306e\u5c0f\u3055\u306a\u30ac\u30e9\u30b9\u90e8\u54c1\u304c\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u6790\u5168\u4f53\u306e\u54c1\u8cea\u3092\u3053\u308c\u307b\u3069\u5de6\u53f3\u3059\u308b\u306e\u306f\u8208\u5473\u6df1\u3044\u3053\u3068\u3067\u3059\u3002\u307b\u3068\u3093\u3069\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u306f\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u90e8\u3067\u6db2\u4f53\u304b\u3089\u30ac\u30b9\u3078\u3068\u6c17\u5316\u3057\u3001\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u3078\u3068\u79fb\u9001\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u30d7\u30ed\u30bb\u30b9\u304c\u3046\u307e\u304f\u3044\u304f\u304b\u3069\u3046\u304b\u3067\u3001\u5206\u6790\u306e\u6210\u5426\u304c\u6c7a\u307e\u308a\u307e\u3059\u3002\u3060\u304b\u3089\u3053\u305d\u3001\u7528\u9014\u306b\u5408\u3063\u305f\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u3076\u3053\u3068\u304c\u975e\u5e38\u306b\u91cd\u8981\u306a\u306e\u3067\u3059\u3002<\/p>\n<p>\u91cd\u8981\u306a\u9078\u629e\u3067\u306f\u3042\u308a\u307e\u3059\u304c\u3001\u96e3\u3057\u304f\u8003\u3048\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u5927\u534a\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u9078\u629e\u80a2\u306f\u305d\u308c\u307b\u3069\u591a\u304f\u306a\u304f\u3001\u4f7f\u7528\u3059\u308b\u6ce8\u5165\u65b9\u5f0f\u3055\u3048\u6c7a\u307e\u308c\u3070\u3001\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u306f\u81ea\u305a\u3068\u7d5e\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>\u307e\u305a\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u304b\u3089\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30d5\u30ed\u30fc\u304c\u975e\u5e38\u306b\u901f\u3044\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u672c\u6765\u306e\u7d44\u6210\u3092\u53cd\u6620\u3057\u305f\u5f62\u3067\u3001\u518d\u73fe\u6027\u3088\u304f\u7d20\u65e9\u304f\u6c17\u5316\u3055\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30a6\u30fc\u30eb\u304c\u30b5\u30f3\u30d7\u30eb\u3092\u4e00\u77ac\u53d7\u3051\u6b62\u3081\u3066\u6c17\u5316\u3092\u4fc3\u3057\u307e\u3059\u3002\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u306e\u3088\u3046\u306b\u9ad8\u901f\u3067\u6ce8\u5165\u3059\u308b\u5834\u5408\u306f\u3001\u3053\u306e\u30a6\u30fc\u30eb\u306e\u5f79\u5272\u304c\u3088\u308a\u4e00\u5c64\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u30a6\u30fc\u30eb\u306f\u591a\u304f\u306e\u5834\u5408\u3001\u6c17\u5316\u3092\u6700\u5927\u9650\u306b\u4fc3\u3059\u305f\u3081\u6ce8\u5165\u53e3\u306e\u9ad8\u6e29\u90e8\u306b\u914d\u7f6e\u3055\u308c\u307e\u3059\u3002\u3067\u3059\u304b\u3089\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u306f\u3001\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc\u304c\u6700\u9069\u3067\u3059\u3002<\/p>\n<p>\u4e00\u65b9\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306e\u5834\u5408\u306f\u3069\u3046\u3067\u3057\u3087\u3046\u304b\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30e2\u30fc\u30c9\u3067\u306f\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30d5\u30ed\u30fc\u304c\u5927\u5e45\u306b\u9045\u304f\u306a\u308a\u307e\u3059\u304c\u3001\u305d\u308c\u3067\u3082\u30a6\u30fc\u30eb\u5145\u586b\u30e9\u30a4\u30ca\u30fc\u306e\u4f7f\u7528\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u6ce8\u5165\u76f4\u5f8c\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u53d7\u3051\u6b62\u3081\u3001\u5747\u4e00\u306a\u6c17\u5316\u3092\u4fc3\u3059\u305f\u3081\u3067\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u306f\u3001\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u304c\u6700\u9069\u3067\u3059\u3002\u30d5\u30ed\u30fc\u304c\u9045\u304f\u306a\u308b\u3068\u3044\u3046\u30c8\u30ec\u30fc\u30c9\u30aa\u30d5\u306f\u3042\u308a\u307e\u3059\u304c\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u5747\u4e00\u306b\u6c17\u5316\u3055\u305b\u3066\u30ab\u30e9\u30e0\u3078\u78ba\u5b9f\u306b\u79fb\u9001\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u307e\u3068\u3081\u308b\u3068\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u306f\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u306f\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u304c\u6700\u9069\u3067\u3059\u3002\u30a6\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u554f\u984c\u304c\u751f\u3058\u305f\u5834\u5408\u306b\u306e\u307f\u3001\u4ed6\u306e\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u3092\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u79c1\u306e\u30e9\u30a4\u30ca\u30fc\u71b1\u3001\u5c11\u3057\u306f\u4f1d\u308f\u308a\u307e\u3057\u305f\u304b\uff1f\u305c\u3072\u7686\u3055\u3093\u306b\u3082\u30e9\u30a4\u30ca\u30fc\u9078\u3073\u3092\u697d\u3057\u3093\u3067\u3044\u305f\u3060\u3051\u308c\u3070\u3068\u601d\u3044\u307e\u3059\u3002Restek Tip\u3078\u306e\u3054\u53c2\u52a0\u3001\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002<\/p>\n<\/div>\n<\/details>\n\n<h2>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067\u30e9\u30a4\u30ca\u30fc\u9078\u3073\u304c\u5909\u308f\u308b\u7406\u7531<\/h2>\n<p>\u6ce8\u5165\u53e3\u304b\u3089\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u306f\u3001GC\u5206\u96e2\u306e\u6210\u5426\u3092\u5de6\u53f3\u3059\u308b\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u79fb\u9001\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u8981\u56e0\u306f\u6570\u591a\u304f\u3042\u308a\u307e\u3059\u304c\u3001\u6700\u521d\u306b\u691c\u8a0e\u3059\u3079\u304d\u306f\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u3067\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3068\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u5185\u3067\u30b5\u30f3\u30d7\u30eb\u304c\u3069\u306e\u3088\u3046\u306b\u6c17\u5316\u30fb\u79fb\u9001\u3055\u308c\u308b\u304b\u304c\u6839\u672c\u7684\u306b\u7570\u306a\u308b\u305f\u3081\u3001\u6ce8\u5165\u65b9\u5f0f\u3054\u3068\u306b\u9069\u3057\u305f\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u3082\u5909\u308f\u308a\u307e\u3059\u3002<\/p>\n\n<h3>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\uff1a\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc<\/h3>\n<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30d5\u30ed\u30fc\u304c\u975e\u5e38\u306b\u901f\u3044\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u672c\u6765\u306e\u7d44\u6210\u3092\u53cd\u6620\u3057\u305f\u5f62\u3067\u3001\u518d\u73fe\u6027\u3088\u304f\u7d20\u65e9\u304f\u6c17\u5316\u3055\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30a6\u30fc\u30eb\u304c\u30b5\u30f3\u30d7\u30eb\u3092\u4e00\u77ac\u53d7\u3051\u6b62\u3081\u3066\u6c17\u5316\u3092\u4fc3\u3059\u5f79\u5272\u3092\u679c\u305f\u3057\u3001\u7279\u306b\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u306b\u3088\u308b\u9ad8\u901f\u6ce8\u5165\u3067\u306f\u3001\u3053\u306e\u30a6\u30fc\u30eb\u306e\u5f79\u5272\u304c\u3088\u308a\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u30a6\u30fc\u30eb\u306f\u6c17\u5316\u3092\u6700\u5927\u9650\u306b\u4fc3\u3059\u305f\u3081\u3001\u6ce8\u5165\u53e3\u306e\u9ad8\u6e29\u90e8\u306b\u914d\u7f6e\u3055\u308c\u308b\u306e\u304c\u4e00\u822c\u7684\u3067\u3059\u3002\u3053\u306e\u6761\u4ef6\u304b\u3089\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u306f\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc\u304c\u6700\u9069\u3067\u3059\u3002<\/p>\n\n<h3>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\uff1a\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc<\/h3>\n<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067\u306f\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30d5\u30ed\u30fc\u304c\u5927\u5e45\u306b\u9045\u304f\u306a\u308a\u307e\u3059\u304c\u3001\u305d\u308c\u3067\u3082\u30a6\u30fc\u30eb\u5145\u586b\u30e9\u30a4\u30ca\u30fc\u306e\u4f7f\u7528\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u6ce8\u5165\u76f4\u5f8c\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u53d7\u3051\u6b62\u3081\u3001\u5747\u4e00\u306a\u6c17\u5316\u3092\u4fc3\u3059\u305f\u3081\u3067\u3059\u3002\u30d5\u30ed\u30fc\u304c\u9045\u304f\u306a\u308b\u3068\u3044\u3046\u30c8\u30ec\u30fc\u30c9\u30aa\u30d5\u306f\u3042\u308b\u3082\u306e\u306e\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u5747\u4e00\u306b\u6c17\u5316\u3055\u305b\u3066\u30ab\u30e9\u30e0\u3078\u78ba\u5b9f\u306b\u79fb\u9001\u3067\u304d\u308b\u70b9\u304b\u3089\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u306f\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u304c\u6700\u9069\u3067\u3059\u3002<\/p>\n\n<h3>\u307e\u3068\u3081\uff1a\u6ce8\u5165\u65b9\u5f0f\u5225\u306e\u6700\u9069\u30e9\u30a4\u30ca\u30fc<\/h3>\n<ul>\n<li><strong>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165<\/strong>\uff1a\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc<\/li>\n<li><strong>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165<\/strong>\uff1a\u30a6\u30fc\u30eb\u5145\u586b\u306e\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc<\/li>\n<\/ul>\n<p>\u30a6\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u554f\u984c\u304c\u751f\u3058\u305f\u5834\u5408\u306b\u306e\u307f\u3001\u4ed6\u306e\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u306e\u691c\u8a0e\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n<div class=\"rtk-callout\">\n<p>\u8a73\u3057\u3044\u9078\u3073\u65b9\u306e\u624b\u9806\u306f\u3001<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar1991-ja\/japanese-how-to-choose-a-gc-inlet-liner\" target=\"_blank\" rel=\"noopener\">GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u65b9\uff1a\u6ce8\u5165\u65b9\u6cd5\u5225\u306e\u7c21\u5358\u306a\u30bb\u30ec\u30af\u30b7\u30e7\u30f3\u30ac\u30a4\u30c9<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002\u30e9\u30a4\u30ca\u30fc\u306e\u88fd\u54c1\u30e9\u30a4\u30f3\u30a2\u30c3\u30d7\u306f<a href=\"https:\/\/www.restek.com\/c\/1210\" target=\"_blank\" rel=\"noopener\">GC Inlet Liners<\/a>\u304b\u3089\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n<\/div>\n\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u306a\u305c\u5206\u6790\u7d50\u679c\u306b\u5f71\u97ff\u3059\u308b\u306e\u3067\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u30e9\u30a4\u30ca\u30fc\u306f\u30b5\u30f3\u30d7\u30eb\u304c\u6db2\u4f53\u304b\u3089\u30ac\u30b9\u3078\u6c17\u5316\u3057\u3001\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u3078\u79fb\u9001\u3055\u308c\u308b\u5834\u6240\u3067\u3059\u3002\u6c17\u5316\u30fb\u79fb\u9001\u304c\u4e0d\u5b89\u5b9a\u3060\u3068\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3084\u30ec\u30b9\u30dd\u30f3\u30b9\u3001\u518d\u73fe\u6027\u306b\u76f4\u63a5\u5f71\u97ff\u3059\u308b\u305f\u3081\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u6790\u5168\u4f53\u306e\u54c1\u8cea\u3092\u5de6\u53f3\u3059\u308b\u90e8\u54c1\u3067\u3059\u3002<\/p>\n<\/details>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. \u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3068\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067\u3001\u306a\u305c\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u3092\u5909\u3048\u308b\u5fc5\u8981\u304c\u3042\u308b\u306e\u3067\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306f\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30d5\u30ed\u30fc\u304c\u901f\u304f\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u7d20\u65e9\u304f\u6c17\u5316\u3055\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u65b9\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u30d5\u30ed\u30fc\u304c\u5927\u5e45\u306b\u9045\u304f\u3001\u6ce8\u5165\u76f4\u5f8c\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u53d7\u3051\u6b62\u3081\u3066\u5747\u4e00\u306b\u6c17\u5316\u3055\u305b\u308b\u3053\u3068\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u6c17\u5316\u6761\u4ef6\u306e\u9055\u3044\u306b\u5fdc\u3058\u3066\u3001\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u3082\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/details>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. \u30a6\u30fc\u30eb\u5145\u586b\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u3046\u3068\u3001\u3069\u306e\u3088\u3046\u306a\u5834\u5408\u306b\u5225\u306e\u5f62\u72b6\u3092\u691c\u8a0e\u3059\u3079\u304d\u3067\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u57fa\u672c\u7684\u306b\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u30fb\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306e\u3069\u3061\u3089\u3082\u3001\u30a6\u30fc\u30eb\u5145\u586b\u30e9\u30a4\u30ca\u30fc\uff08\u305d\u308c\u305e\u308c\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc\u3001\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff09\u304c\u6700\u9069\u3067\u3059\u3002\u30a6\u30fc\u30eb\u306e\u4f7f\u7528\u306b\u3088\u3063\u3066\u5206\u6790\u4e0a\u306e\u554f\u984c\u304c\u751f\u3058\u305f\u5834\u5408\u306b\u306e\u307f\u3001\u4ed6\u306e\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u3078\u306e\u5909\u66f4\u3092\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<\/details>\n\n<\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Which liner will work best for my application? We\u2019ll answer this question on this Restek Tip with information on how to pick the right liner for your split and splitless gas chromatography applications.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[2816,2800],"industries-application":[],"post-badge":[],"resource-type":[2802],"product-library":[2494,2480],"resource-technique":[2324],"ppma_author":[414,2814],"class_list":["post-98605","post","type-post","status-publish","format-standard","hentry","category-videos-ja","tag-gc","tag-topaz-liners","resource-type-selection-guides","product-library-inlet-zubehor","product-library-gaschromatographie-produkte","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"post_tag":[{"value":2816,"label":"GC"},{"value":2800,"label":"Topaz Liners"}],"resource-type":[{"value":2802,"label":"Selection Guides"}],"product-library":[{"value":2494,"label":"Inlet Zubeh\u00f6r"},{"value":2480,"label":"Gaschromatographie Produkte"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":774,"category_count":138,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":[{"term_id":2816,"name":"GC","slug":"gc","term_group":0,"term_taxonomy_id":2816,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."},{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=98605"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98605\/revisions"}],"predecessor-version":[{"id":99518,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98605\/revisions\/99518"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=98605"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=98605"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=98605"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=98605"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=98605"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=98605"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=98605"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=98605"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=98605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}