{"id":98610,"date":"2026-04-17T18:35:40","date_gmt":"2026-04-17T18:35:40","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized-ja\/unlock-ultra-low-analysis-of-pesticides-in-cannabis-by-gc-ms-ms\/"},"modified":"2026-07-29T05:01:39","modified_gmt":"2026-07-29T05:01:39","slug":"unlock-ultra-low-analysis-of-pesticides-in-cannabis-by-gc-ms-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/fsfa5659-ja\/unlock-ultra-low-analysis-of-pesticides-in-cannabis-by-gc-ms-ms","title":{"rendered":"GC-MS\/MS\u306b\u3088\u308b\u5927\u9ebb\u4e2d\u8fb2\u85ac\u306e\u8d85\u4f4e\u6fc3\u5ea6\u5206\u6790"},"content":{"rendered":"\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 16px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout {\n    padding: 14px 16px;\n  }\n}\n<\/style>\n<\/style>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article a {\n  font-size: inherit !important;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n<\/style>\n<\/style>\n\n<div class=\"rtk-article\">\n\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">\u5927\u9ebb\u82b1\u90e8\u306f\u8fb2\u85ac\u5206\u6790\u306e\u4e2d\u3067\u3082\u7279\u306b\u96e3\u3057\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u4e00\u3064\u3067\u3059\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u3068Topaz\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u3067\u3082\u8fb2\u85ac\u3092\u30d4\u30b3\u30b0\u30e9\u30e0\u30ec\u30d9\u30eb\u306e\u8d85\u4f4e\u6fc3\u5ea6\u3067\u78ba\u5b9f\u306b\u540c\u5b9a\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<ul>\n<li>TriMax\u6280\u8853\u3068Topaz\u30e9\u30a4\u30ca\u30fc\u306b\u3088\u308b\u4e0d\u6d3b\u6027\u5316\u3067\u3001\u5fae\u91cf\u30ec\u30d9\u30eb\u5206\u6790\u306b\u304a\u3051\u308b\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u6539\u5584<\/li>\n<li>\u5e45\u5e83\u3044GC\u5bfe\u5fdc\u8fb2\u85ac\u306b\u304a\u3044\u3066\u30d4\u30b3\u30b0\u30e9\u30e0\u30ec\u30d9\u30eb\u3067\u306e\u691c\u51fa\u611f\u5ea6\u304c\u5b9f\u73fe<\/li>\n<li>\u8907\u96d1\u306a\u5927\u9ebb\u82b1\u90e8\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u304a\u3044\u3066\u3082\u8fb2\u85ac\u306e\u78ba\u5b9f\u306a\u540c\u5b9a\u304c\u53ef\u80fd<\/li>\n<\/ul>\n\n<h2>\u5927\u9ebb\u4e2d\u8fb2\u85ac\u5206\u6790\u304c\u96e3\u3057\u3044\u7406\u7531\uff1a\u898f\u5236\u5909\u52d5\u30fb\u8907\u96d1\u306a\u5206\u6790\u5bfe\u8c61\u6210\u5206\u30fb\u591a\u69d8\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9<\/h2>\n<p>\u5927\u9ebb\u8a66\u9a13\u30e9\u30dc\u306b\u3068\u3063\u3066\u8fb2\u85ac\u5206\u6790\u306f\u4f9d\u7136\u3068\u3057\u3066\u96e3\u3057\u304f\u3001\u7d99\u7d9a\u7684\u306a\u5bfe\u5fdc\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u4e3b\u306a\u80cc\u666f\u306f\u4ee5\u4e0b\u306e3\u70b9\u3067\u3059\u3002<\/p>\n<ul>\n<li><strong>\u898f\u5236\u74b0\u5883\u306e\u5909\u5316<\/strong>\uff1a\u898f\u5236\u306f\u5dde\u3054\u3068\u306b\u7570\u306a\u308a\u3001\u5bfe\u8c61\u5316\u5408\u7269\u3082\u6fc3\u5ea6\u57fa\u6e96\u3082\u3055\u307e\u3056\u307e\u3067\u3059\u3002<\/li>\n<li><strong>\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u8907\u96d1\u3055<\/strong>\uff1a\u591a\u5c90\u306b\u308f\u305f\u308b\u5316\u5b66\u69cb\u9020\u306e\u8fb2\u85ac\u304c\u5206\u6790\u5bfe\u8c61\u3068\u306a\u308a\u307e\u3059\u3002<\/li>\n<li><strong>\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u591a\u69d8\u3055<\/strong>\uff1a\u690d\u7269\u4f53\u304b\u3089\u30a8\u30c7\u30a3\u30d6\u30eb\u3001\u6fc3\u7e2e\u7269\u307e\u3067\u3001\u5206\u6790\u304c\u96e3\u3057\u3044\u591a\u69d8\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3078\u306e\u5bfe\u5fdc\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n<p>\u30b5\u30f3\u30d7\u30eb\u3092\u5e0c\u91c8\u3059\u308c\u3070\u5c0e\u5165\u3055\u308c\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u91cf\u304c\u6e1b\u308a\u3001\u88c5\u7f6e\u306e\u7a3c\u50cd\u6642\u9593\u3092\u5ef6\u3070\u305b\u307e\u3059\u3002\u3057\u304b\u3057\u76ee\u7684\u6210\u5206\u306e\u6fc3\u5ea6\u3082\u4f4e\u4e0b\u3059\u308b\u305f\u3081\u3001\u691c\u51fa\u306f\u3088\u308a\u56f0\u96e3\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n<h2>\u5927\u9ebb\u4e2d\u8fb2\u85ac\u306e\u4f4e\u6fc3\u5ea6\u5206\u6790\u306b\u6c42\u3081\u3089\u308c\u308b\u6761\u4ef6\uff1a\u9ad8\u4e0d\u6d3b\u6027\u5ea6\u30ab\u30e9\u30e0RMX-5Sil MS<\/h2>\n<p>\u5927\u9ebb\u4e2d\u8fb2\u85ac\u3092\u6b63\u78ba\u304b\u3064\u4f4e\u6fc3\u5ea6\u3067\u5206\u6790\u3059\u308b\u306b\u306f\u3001\u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u30d5\u30ed\u30fc\u30d1\u30b9\u304c\u524d\u63d0\u3068\u306a\u308a\u307e\u3059\u3002\u7279\u306b\u30ab\u30e9\u30e0\u306e\u4e0d\u6d3b\u6027\u5ea6\u304c\u5206\u6790\u7d50\u679c\u3092\u5de6\u53f3\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306e\u8868\u9762\u51e6\u7406\u304c\u5341\u5206\u3067\u306a\u3044\u5834\u5408\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u30ab\u30e9\u30e0\u8868\u9762\u306e\u6d3b\u6027\u30b5\u30a4\u30c8\u3068\u76f8\u4e92\u4f5c\u7528\u3057\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u30ec\u30b9\u30dd\u30f3\u30b9\u306b\u5f71\u97ff\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u4f4e\u6fc3\u5ea6\u5206\u6790\u306b\u306a\u308b\u307b\u3069\u9855\u8457\u3067\u3042\u308a\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/17323\" target=\"_blank\" rel=\"noopener\">RMX-5Sil MS\u30ab\u30e9\u30e0<\/a>\u306f\u3053\u306e\u8ab2\u984c\u306b\u6709\u52b9\u306a\u9078\u629e\u80a2\u3067\u3059\u3002<\/p>\n<p>RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u9ad8\u4e0d\u6d3b\u6027\u5ea6\u30fb\u9577\u5bff\u547d\u30fb\u9ad8\u52b9\u7387\u3092\u5099\u3048\u305fGC-MS\/MS\u9ad8\u611f\u5ea6\u5206\u6790\u5411\u3051\u306e\u30ab\u30e9\u30e0\u3067\u3059\u3002\u72ec\u81ea\u306e<strong>TriMax\u4e0d\u6d3b\u6027\u5316\u6280\u8853<\/strong>\u306b\u3088\u308a\u3001\u30dd\u30ea\u30de\u30fc\u3068\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30c1\u30e5\u30fc\u30d6\u306e\u754c\u9762\u304c\u5b89\u5b9a\u3057\u3066\u4fdd\u305f\u308c\u307e\u3059\u3002\u71b1\u3084\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u8d77\u56e0\u3059\u308b\u30b9\u30c8\u30ec\u30b9\u306b\u5bfe\u3057\u3066\u3082\u8868\u9762\u306e\u5b89\u5b9a\u6027\u304c\u7dad\u6301\u3055\u308c\u308b\u305f\u3081\u3001\u9577\u671f\u9593\u306b\u308f\u305f\u3063\u3066\u9ad8\u3044\u5206\u6790\u6027\u80fd\u304c\u6301\u7d9a\u3057\u307e\u3059\u3002<\/p>\n\n<h2>\u5927\u9ebb\u82b1\u90e8\u306b\u304a\u3051\u308b\u8fb2\u85ac\u4f4e\u6fc3\u5ea6\u5206\u6790\u306e\u8a55\u4fa1\uff1aRMX-5Sil MS\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u691c\u8a3c<\/h2>\n<p><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/17323\" target=\"_blank\" rel=\"noopener\">RMX-5Sil MS\u30ab\u30e9\u30e0<\/a>\u306e\u6027\u80fd\u691c\u8a3c\u3068\u3057\u3066\u3001\u96e3\u3057\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3068\u3057\u3066\u77e5\u3089\u308c\u308b\u5927\u9ebb\u82b1\u90e8\u3092\u7528\u3044\u305f\u8fb2\u85ac\u4f4e\u6fc3\u5ea6\u5206\u6790\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u969b\u306b<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23267\" target=\"_blank\" rel=\"noopener\">Topaz\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc<\/a>\u3092\u4f7f\u7528\u3057\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u30d5\u30ed\u30fc\u30d1\u30b9\u5168\u4f53\u306e\u4e0d\u6d3b\u6027\u5ea6\u3092\u9ad8\u3081\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u524d\u51e6\u7406\u624b\u6cd5\u306f\u30e9\u30dc\u306b\u3088\u3063\u3066\u5927\u304d\u304f\u7570\u306a\u308a\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u52b9\u7387\u306e\u5f71\u97ff\u3092\u6392\u9664\u3059\u308b\u305f\u3081\u3001\u5927\u9ebb\u82b1\u90e8\u62bd\u51fa\u6db2\uff08\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u53c2\u7167\uff09\u306b30\u7a2e\u306e\u8fb2\u85ac\uff08\u3055\u307e\u3056\u307e\u306a\u5316\u5b66\u69cb\u9020\u3092\u30ab\u30d0\u30fc\uff09\u3092\u62bd\u51fa\u5f8c\u306b1.7 ng\/mL\u3067\u6dfb\u52a0\u3057\u3001\u5206\u6790\u7d50\u679c\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u6fc3\u5ea6\u306f\u5927\u9ebb\u82b1\u90e8\u4e2d0.1 \u00b5g\/g\u8fb2\u85ac\u306b\u76f8\u5f53\u3057\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u63db\u7b97\u30670.17 pg\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n<h2>RMX-5Sil MS\u30ab\u30e9\u30e0\u3068Topaz\u30e9\u30a4\u30ca\u30fc\u306b\u3088\u308b\u8fb2\u85ac\u5206\u6790\u7d50\u679c\uff1a\u5bfe\u79f0\u6027\u306e\u9ad8\u3044\u30d4\u30fc\u30af\u3068\u6b63\u78ba\u306a\u89e3\u6790<\/h2>\n<p>RMX-5Sil MS\u30ab\u30e9\u30e0\u3067\u306f\u5bfe\u79f0\u6027\u306e\u9ad8\u3044\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5f97\u3089\u308c\u3001\u6b63\u78ba\u306a\u89e3\u6790\u3092\u7c21\u5358\u306b\u884c\u3048\u307e\u3057\u305f\u300230\u7a2e\u306e\u8fb2\u85ac\u30923\u56de\u7e70\u308a\u8fd4\u3057\u6ce8\u5165\u3057\u305f\u7d50\u679c\u3001\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u306e\u5e73\u5747\u5024\u306f1.00 \u00b1 0.14\u3068\u306a\u308a\u3001\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306e\u6975\u3081\u3066\u4f4e\u3044\u6fc3\u5ea6\u3067\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3082\u3001\u30b5\u30f3\u30d7\u30eb\u30d5\u30ed\u30fc\u30d1\u30b9\u304c\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u7dad\u6301\u3057\u3001\u8fb2\u85ac\u30d4\u30fc\u30af\u304c\u63a8\u5968\u7bc4\u56f2\uff080.8\u301c1.2\uff09\u306b\u53ce\u307e\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u9ad8\u611f\u5ea6\u30b7\u30b9\u30c6\u30e0\u3067\u3042\u308bGC-MS\/MS\u3067\u306f\u3001\u672c\u6765\u306e\u6027\u80fd\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044\u6d88\u8017\u54c1\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u4eca\u56de\u306e\u7d50\u679c\u304c\u793a\u3059\u3068\u304a\u308a\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/17323\" target=\"_blank\" rel=\"noopener\">RMX-5Sil MS\u30ab\u30e9\u30e0<\/a>\u3068<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23267\" target=\"_blank\" rel=\"noopener\">Topaz\u30e9\u30a4\u30ca\u30fc<\/a>\u306f\u5927\u9ebb\u82b1\u90e8\u4e2d\u8fb2\u85ac\u306e\u5206\u6790\u306b\u9069\u3057\u305f\u9078\u629e\u80a2\u3067\u3059\u3002<\/p>\n\n<div class=\"rtk-callout\">\n<p><strong>Figure 1:<\/strong> RMX-5Sil MS\u30ab\u30e9\u30e0\u3068Topaz\u30e9\u30a4\u30ca\u30fc\u306e\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u306b\u3088\u308a\u3001\u5927\u9ebb\u4e2d\u8fb2\u85ac\u306e\u5fae\u91cf\u30ec\u30d9\u30eb\u5206\u6790\u306b\u304a\u3044\u3066\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5f97\u3089\u308c\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u53ca\u3073\u5206\u6790\u6761\u4ef6\u306fPDF\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3067\u78ba\u8a8d\u53ef\u80fd\uff09\u3002<\/p>\n<\/div>\n<\/div><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1399.png\" alt=\"Low-Level Pesticides in Cannabis Flower on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1399<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32592<\/li><li>17323<\/li><li>23267<\/li><li>32592<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>cannabis<\/li><li>flower<\/li><li>low-level<\/li><li>matrix<\/li><li>pesticides<\/li><li>rmx<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1399.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n<details class=\"rtk-faq\">\n<summary>\n<h3>Q. \u5927\u9ebb\u4e2d\u306e\u8fb2\u85ac\u5206\u6790\u306f\u306a\u305c\u96e3\u3057\u3044\u306e\u3067\u3059\u304b\uff1f<\/h3>\n<\/summary>\n<p>\u5dde\u3054\u3068\u306b\u898f\u5236\u3084\u5bfe\u8c61\u5316\u5408\u7269\u3001\u6fc3\u5ea6\u57fa\u6e96\u304c\u7570\u306a\u308b\u3053\u3068\u3001\u5206\u6790\u5bfe\u8c61\u3068\u306a\u308b\u8fb2\u85ac\u306e\u5316\u5b66\u69cb\u9020\u304c\u591a\u5c90\u306b\u308f\u305f\u308b\u3053\u3068\u3001\u690d\u7269\u4f53\u304b\u3089\u30a8\u30c7\u30a3\u30d6\u30eb\u30fb\u6fc3\u7e2e\u7269\u307e\u3067\u5bfe\u5fdc\u3059\u3079\u304d\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304c\u591a\u69d8\u3067\u3042\u308b\u3053\u3068\u304c\u4e3b\u306a\u7406\u7531\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u3092\u5e0c\u91c8\u3059\u308b\u3068\u76ee\u7684\u6210\u5206\u306e\u6fc3\u5ea6\u3082\u4e0b\u304c\u308b\u305f\u3081\u3001\u4f4e\u6fc3\u5ea6\u3067\u306e\u691c\u51fa\u306f\u3055\u3089\u306b\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/details>\n<details class=\"rtk-faq\">\n<summary>\n<h3>Q. RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3069\u306e\u3088\u3046\u306a\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u304b\uff1f<\/h3>\n<\/summary>\n<p>\u9ad8\u4e0d\u6d3b\u6027\u5ea6\u30fb\u9577\u5bff\u547d\u30fb\u9ad8\u52b9\u7387\u3092\u5099\u3048\u305fGC-MS\/MS\u9ad8\u611f\u5ea6\u5206\u6790\u5411\u3051\u306e\u30ab\u30e9\u30e0\u3067\u3001\u5927\u9ebb\u82b1\u90e8\u306e\u3088\u3046\u306a\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306e\u8fb2\u85ac\u3092\u4f4e\u6fc3\u5ea6\u3067\u5206\u6790\u3059\u308b\u7528\u9014\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u72ec\u81ea\u306eTriMax\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u306b\u3088\u308a\u3001\u71b1\u3084\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u8d77\u56e0\u3059\u308b\u30b9\u30c8\u30ec\u30b9\u306b\u5bfe\u3057\u3066\u3082\u8868\u9762\u306e\u5b89\u5b9a\u6027\u304c\u9577\u671f\u9593\u7dad\u6301\u3055\u308c\u307e\u3059\u3002<\/p>\n<\/details>\n<details class=\"rtk-faq\">\n<summary>\n<h3>Q. \u4eca\u56de\u306e\u691c\u8a3c\u3067\u306f\u3001\u3069\u306e\u7a0b\u5ea6\u306e\u4f4e\u6fc3\u5ea6\u307e\u3067\u8fb2\u85ac\u3092\u5206\u6790\u3057\u3066\u3044\u307e\u3059\u304b\uff1f<\/h3>\n<\/summary>\n<p>\u5927\u9ebb\u82b1\u90e8\u62bd\u51fa\u6db2\u306b30\u7a2e\u306e\u8fb2\u85ac\u30921.7 ng\/mL\u3067\u6dfb\u52a0\u3057\u3066\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u5927\u9ebb\u82b1\u90e8\u4e2d0.1 \u00b5g\/g\u8fb2\u85ac\u306b\u76f8\u5f53\u3057\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u63db\u7b97\u3067\u306f0.17 pg\u306b\u76f8\u5f53\u3057\u307e\u3059\u3002\u3053\u306e\u6fc3\u5ea6\u3067\u3082\u3001\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u306e\u5e73\u5747\u5024\u306f1.00 \u00b1 0.14\u3068\u3001\u63a8\u5968\u7bc4\u56f2\uff080.8\u301c1.2\uff09\u306b\u53ce\u307e\u308b\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n<\/details>\n<\/div>\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">                                \u30ab\u30bf\u30ed\u30b0No. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/32592\">                                \u30ab\u30bf\u30ed\u30b0No. 32592                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Canadian Pesticide Standards Kit, 1 mL\/ampul; 8 ampuls\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/32592\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23267\">                                \u30ab\u30bf\u30ed\u30b0No. 23267                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Thermo TRACE 1300\/1310, 1600\/1610 GCs w\/SSL Inlets, Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23267\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22656\">                                \u30ab\u30bf\u30ed\u30b0No. 22656                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek ProFLOW 6000 \u6d41\u91cf\u8a08<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22656\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5927\u9ebb\u4e2d\u8fb2\u85ac\u306eGC-MS\/MS\u5206\u6790\u306b\u304a\u3044\u3066\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u3068Topaz\u30e9\u30a4\u30ca\u30fc\u306e\u7d44\u307f\u5408\u308f\u305b\u3067\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u691c\u51fa\u611f\u5ea6\u3092\u6539\u5584\u3002TriMax\u4e0d\u6d3b\u6027\u5316\u304c\u30d4\u30b3\u30b0\u30e9\u30e0\u30ec\u30d9\u30eb\u306e\u9ad8\u611f\u5ea6\u5206\u6790\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":34,"featured_media":92839,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[2745],"industries-application":[2263,2282],"post-badge":[2752],"resource-type":[2803],"product-library":[2564,2552],"resource-technique":[2365,2340],"ppma_author":[454],"class_list":["post-98610","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-rmx-resources","industries-application-cannabis-ja","industries-application-medical-recreational-cannabis-ja","post-badge-new","resource-type-featured-application","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-ms-ms-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2745,"label":"RMX \u8d44\u6e90\u5e93"}],"industries-application":[{"value":2263,"label":"\u30ab\u30f3\u30ca\u30d3\u30b9"},{"value":2282,"label":"\u533b\u7642\u7528\uff5c\u55dc\u597d\u7528 \u30ab\u30f3\u30ca\u30d3\u30b9"}],"post-badge":[{"value":2752,"label":"New"}],"resource-type":[{"value":2803,"label":"Featured Application"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-fsfa5659-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Erica Pack, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/erica-pack-phd\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2745,"name":"RMX \u8d44\u6e90\u5e93","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2745,"taxonomy":"post_tag","description":"\u7acb\u5373\u63a2\u7d22 RMX \u8d44\u6e90\u5e93","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=98610"}],"version-history":[{"count":17,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98610\/revisions"}],"predecessor-version":[{"id":99670,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/98610\/revisions\/99670"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/92839"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=98610"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=98610"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=98610"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=98610"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=98610"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=98610"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=98610"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=98610"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=98610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}