{"id":99364,"date":"2012-12-18T00:00:00","date_gmt":"2012-12-18T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized-ja\/handling-your-analytical-reference-standards\/"},"modified":"2026-10-02T18:02:18","modified_gmt":"2026-10-02T18:02:18","slug":"handling-your-analytical-reference-standards","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs\/gnbl5498-ja\/handling-your-analytical-reference-standards","title":{"rendered":"\u5206\u6790\u7528\u6a19\u6e96\u6eb6\u6db2\u306e\u53d6\u308a\u6271\u3044\u30ac\u30a4\u30c9\uff5c\u4fdd\u7ba1\u6e29\u5ea6\u30fb\u5149\u611f\u53d7\u6027\u30fb\u5316\u5408\u7269\u306e\u9069\u5408\u6027"},"content":{"rendered":"\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article a {\n  font-size: inherit !important;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n\n<div class=\"rtk-intro\">\n<p class=\"rtk-lead\">\u3059\u3079\u3066\u306e\u6a19\u6e96\u6eb6\u6db2\u306b\u7279\u5225\u306a\u53d6\u308a\u6271\u3044\u6307\u793a\u304c\u3042\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u4fdd\u7ba1\u6e29\u5ea6\u30fb\u5149\u611f\u53d7\u6027\u30fb\u5316\u5408\u7269\u9593\u306e\u9069\u5408\u6027\u3092\u6b63\u3057\u304f\u7406\u89e3\u3057\u3066\u304a\u304f\u3053\u3068\u3067\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u30ed\u30b9\u3084\u691c\u51fa\u6f0f\u308c\u3092\u9632\u3052\u307e\u3059\u3002<\/p>\n<\/div>\n\n<p>\u3053\u308c\u307e\u3067GC\u30ab\u30e9\u30e0\u3001LC\u30ab\u30e9\u30e0\u3001\u691c\u51fa\u5668\u3001\u30b7\u30ea\u30f3\u30b8\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3001TO\u30ad\u30e3\u30cb\u30b9\u30bf\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u30c6\u30fc\u30de\u3092\u53d6\u308a\u4e0a\u3052\u3066\u304d\u307e\u3057\u305f\u3002\u4eca\u56de\u306f\u305d\u306e\u4e2d\u3067\u307e\u3060\u89e6\u308c\u3066\u3044\u306a\u304b\u3063\u305f\u300c\u5206\u6790\u7528\u6a19\u6e96\u6eb6\u6db2\u300d\u306e\u53d6\u308a\u6271\u3044\u306b\u3064\u3044\u3066\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u6a19\u6e96\u6eb6\u6db2\u306b\u7279\u5225\u306a\u53d6\u308a\u6271\u3044\u6307\u793a\u304c\u3042\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u9069\u5207\u306b\u53d6\u308a\u6271\u3046\u305f\u3081\u306e\u4e00\u822c\u7684\u306a\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3092\u3053\u3053\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n<div style=\"margin-top: 4em;\"><\/div>\n\n<h2>\u4fdd\u7ba1\u6e29\u5ea6\u306e\u9078\u3073\u65b9\uff5c\u5316\u5408\u7269\u306e\u63ee\u767a\u6027\u306b\u5fdc\u3058\u305f\u4f7f\u3044\u5206\u3051<\/h2>\n<p>\u4fdd\u7ba1\u6e29\u5ea6\u306f\u6a19\u6e96\u6eb6\u6db2\u306e\u54c1\u8cea\u306b\u5927\u304d\u304f\u5f71\u97ff\u3057\u307e\u3059\u3002\u5316\u5408\u7269\u306e\u7a2e\u985e\u306b\u5fdc\u3058\u3066\u3001\u4ee5\u4e0b\u306e\u4fdd\u7ba1\u6761\u4ef6\u3092\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n<h3>\u51b7\u51cd\u4fdd\u7ba1\uff1a\u63ee\u767a\u6027\u5316\u5408\u7269<\/h3>\n<p>\u5869\u5316\u30d3\u30cb\u30eb\u304b\u3089\u30ca\u30d5\u30bf\u30ec\u30f3\u307e\u3067\u306e\u63ee\u767a\u6027\u5316\u5408\u7269\u306f\u3001\u5ba4\u6e29\u3067\u5bb9\u6613\u306b\u84b8\u767a\u3059\u308b\u305f\u3081\u3001\u51b7\u51cd\u4fdd\u7ba1\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u3057\u3063\u304b\u308a\u3068\u5bc6\u9589\u3057\u305f\u30d0\u30a4\u30a2\u30eb\u3067\u4fdd\u7ba1\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n<h3>\u51b7\u8535\u4fdd\u7ba1\uff1a\u4f4e\u63ee\u767a\u6027\u5316\u5408\u7269<\/h3>\n<p>PAH\u3084\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u306a\u3069\u306e\u4f4e\u63ee\u767a\u6027\u5316\u5408\u7269\u306f\u3001\u51b7\u8535\u4fdd\u7ba1\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<\/p>\n\n<h3>\u5ba4\u6e29\u4fdd\u7ba1\uff1aAroclor\u306e\u3088\u3046\u306a\u5316\u5408\u7269<\/h3>\n<p>Aroclor\u306e\u3088\u3046\u306a PCB\u985e\u306f\u3001\u5ba4\u6e29\u4fdd\u7ba1\u3067\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n<h3>\u51b7\u51cd\u4fdd\u7ba1\u4e2d\u306b\u6790\u51fa\u304c\u898b\u3089\u308c\u308b\u5834\u5408\u306e\u5bfe\u51e6<\/h3>\n<p>CoA\u306b\u300c10\u00b0C\u672a\u6e80\u300d\u3068\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u4f4e\u63ee\u767a\u6027\u5316\u5408\u7269\u3092\u51b7\u51cd\u4fdd\u7ba1\u3057\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u5ba4\u6e29\u306b\u623b\u3057\u305f\u5f8c\u3001\u8d85\u97f3\u6ce2\u6d17\u6d44\u6a5f\u306710\u301c15\u5206\u51e6\u7406\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u51b7\u51cd\u4fdd\u7ba1\u4e2d\u306b\u6790\u51fa\u3057\u305f\u5316\u5408\u7269\u306f\u3001\u305d\u306e\u307e\u307e\u5206\u6790\u306b\u4f7f\u7528\u3059\u308b\u3068\u691c\u51fa\u3055\u308c\u306a\u3044\u3001\u307e\u305f\u306f\u6fc3\u5ea6\u304c\u4f4e\u304f\u51fa\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u8d85\u97f3\u6ce2\u51e6\u7406\u306b\u3088\u3063\u3066\u6eb6\u6db2\u4e2d\u306b\u518d\u6eb6\u89e3\u3055\u305b\u308b\u3053\u3068\u3067\u3001\u3053\u306e\u554f\u984c\u3092\u9632\u3052\u307e\u3059\u3002<\/p><\/div>\n\n\n<style>.kb-image99364_bc1e81-6a .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image99364_bc1e81-6a size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"250\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-handling-your-analytical-reference-standards-01.jpg\" alt=\"\" class=\"kb-img wp-image-77874\" title=\"-\"><\/figure>\n\n\n\n<style data-wp-block-html=\"css\">\n<style>\n.rtk-article { line-height: 1.8; font-size: 16px; }\n\n.rtk-article .rtk-intro {\n  margin-bottom: 2em;\n}\n\n.rtk-article h2 {\n  margin-top: 4em;\n  margin-bottom: 1em;\n  padding-bottom: 0.3em;\n  border-bottom: 2px solid #0d7bc4;\n}\n.rtk-article > h2:first-of-type {\n  margin-top: 0;\n}\n\n.rtk-article h3 {\n  margin-top: 2.4em;\n  margin-bottom: 0.5em;\n  padding-left: 12px;\n  border-left: 4px solid #0d7bc4;\n}\n\n.rtk-article h4 {\n  margin-top: 1.6em;\n  margin-bottom: 0.3em;\n}\n\n.rtk-article p {\n  font-size: 18px;\n  margin-top: 0;\n  margin-bottom: 0.6em;\n}\n\n.rtk-article a {\n  font-size: inherit !important;\n}\n\n.rtk-article ul,\n.rtk-article .rtk-coa-list {\n  margin-top: 0.4em;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article img {\n  margin-top: 0.8em;\n  margin-bottom: 1.6em;\n  border-radius: 6px;\n}\n\n.rtk-article .rtk-lead {\n  font-size: 18px;\n  background: #f5f9fc;\n  border-left: 4px solid #0d7bc4;\n  padding: 18px 22px;\n  border-radius: 4px;\n  margin-bottom: 1.2em;\n}\n\n.rtk-article .rtk-callout {\n  background: #eef6fc;\n  border: 1px solid #cde3f2;\n  border-radius: 6px;\n  padding: 14px 20px;\n  margin: 1.8em 0 2.2em;\n}\n.rtk-article .rtk-callout p { margin-bottom: 0; }\n.rtk-article .rtk-callout a { font-weight: 700; }\n\n.rtk-article blockquote.rtk-voc {\n  position: relative;\n  border-left: 4px solid #00265d;\n  background: #f7f8f9;\n  padding: 18px 22px 18px 30px;\n  margin: 2em 0;\n  font-style: italic;\n  color: #333;\n}\n.rtk-article blockquote.rtk-voc p { margin-bottom: 0.4em; }\n.rtk-article blockquote.rtk-voc cite {\n  display: block;\n  font-style: normal;\n  font-size: 13px;\n  color: #4a4a4a;\n}\n\n.rtk-article .rtk-coa-list {\n  list-style: none;\n  padding: 0;\n}\n.rtk-article .rtk-coa-list li {\n  background: #fafbfc;\n  border: 1px solid #e1e8ec;\n  border-radius: 6px;\n  padding: 14px 18px;\n  margin-bottom: 12px;\n}\n\n.rtk-article details.rtk-faq {\n  border: 1px solid #d8e3e6;\n  border-radius: 6px;\n  margin-bottom: 8px;\n  overflow: hidden;\n}\n.rtk-article details.rtk-faq summary {\n  cursor: pointer;\n  padding: 14px 18px;\n  background: #f5f9fc;\n  list-style: none;\n}\n.rtk-article details.rtk-faq summary::-webkit-details-marker { display: none; }\n.rtk-article details.rtk-faq summary h3 {\n  display: inline;\n  margin: 0;\n  padding: 0;\n  border: none;\n  font-size: 16px;\n}\n.rtk-article details.rtk-faq summary::after {\n  content: \"+\";\n  float: right;\n  font-weight: 700;\n  color: #0d7bc4;\n}\n.rtk-article details.rtk-faq[open] summary::after { content: \"\uff0d\"; }\n.rtk-article details.rtk-faq > p {\n  padding: 14px 18px;\n  margin: 0;\n}\n\n@media screen and (max-width: 767px) {\n  .rtk-article h2 { margin-top: 2.8em; }\n  .rtk-article h3 { margin-top: 1.8em; }\n  .rtk-article .rtk-lead,\n  .rtk-article .rtk-callout,\n  .rtk-article blockquote.rtk-voc {\n    padding: 14px 16px;\n  }\n}\n<\/style>\n\n<div class=\"rtk-article\">\n\n<div style=\"margin-top: 4em;\"><\/div>\n\n<h2>\u5149\u611f\u53d7\u6027\u5316\u5408\u7269\u306e\u4fdd\u8b77\uff5c\u906e\u5149\u30d0\u30a4\u30a2\u30eb\u3068\u4f5c\u696d\u74b0\u5883\u306e\u5de5\u592b<\/h2>\n<p>\u5149\u306b\u654f\u611f\u306a\u5316\u5408\u7269\u306f\u3001\u5149\u306b\u3055\u3089\u3055\u308c\u308b\u3068\u5bb9\u6613\u306b\u5206\u89e3\u3057\u307e\u3059\u3002\u6709\u6a5f\u30ea\u30f3\u7cfb\u8fb2\u85ac\u306a\u3069\u306e\u5149\u611f\u53d7\u6027\u5316\u5408\u7269\u306f\u3001\u8910\u8272\u30d0\u30a4\u30a2\u30eb\u306b\u4fdd\u7ba1\u3059\u308b\u3053\u3068\u3067\u4fdd\u8b77\u3067\u304d\u307e\u3059\u3002Restek\u3067\u306f\u3001\u3053\u306e\u305f\u3081\u306b\u3059\u3079\u3066\u306e\u6a19\u6e96\u6eb6\u6db2\u306b\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u306e\u8910\u8272\u4e8c\u6b21\u30d0\u30a4\u30a2\u30eb\u3092\u540c\u68b1\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u5ba4\u6e29\u4fdd\u7ba1\u306e\u3082\u306e\u3082\u542b\u3081\u3001\u6a19\u6e96\u6eb6\u6db2\u306f\u5e38\u306b\u5149\u3092\u907f\u3051\u3066\u4fdd\u7ba1\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u5149\u3078\u306e\u66dd\u9732\u3092\u3055\u3089\u306b\u6291\u3048\u308b\u305f\u3081\u306e\u5de5\u592b\u3068\u3057\u3066\u3001\u9ec4\u8272\u706f\u4e0b\u3067\u306e\u4f5c\u696d\u3084\u3001\u5e0c\u91c8\u8abf\u88fd\u6642\u306e\u8d64\u8272\u30ac\u30e9\u30b9\u5668\u5177\u306e\u4f7f\u7528\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u5149\u611f\u53d7\u6027\u5316\u5408\u7269\u3092\u6271\u3046\u5834\u5408\u306f\u3001\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u30d0\u30a4\u30a2\u30eb\u3082\u8910\u8272\u30bf\u30a4\u30d7\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4f7f\u7528\u5f8c\u306f\u3067\u304d\u308b\u3060\u3051\u65e9\u304f\u4fdd\u7ba1\u5834\u6240\u306b\u623b\u3057\u3001\u5149\u3078\u306e\u66dd\u9732\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u307e\u3057\u3087\u3046\u3002<\/p>\n\n<h2>\u5316\u5408\u7269\u9593\u306e\u9069\u5408\u6027\u78ba\u8a8d\uff5c\u6df7\u5408\u6db2\u8abf\u88fd\u6642\u306e\u6ce8\u610f\u70b9<\/h2>\n<p>\u5316\u5408\u7269\u306b\u3088\u3063\u3066\u306f\u3001\u9178\u30fb\u5869\u57fa\u30fb\u4ed6\u306e\u5316\u5408\u7269\u30af\u30e9\u30b9\u307e\u305f\u306f\u7279\u5b9a\u306e\u5316\u5408\u7269\u3068\u53cd\u5fdc\u3059\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u53cd\u5fdc\u306e\u7a2e\u985e\u306f\u591a\u5c90\u306b\u308f\u305f\u308b\u305f\u3081\u3001\u3053\u3053\u3067\u306f\u500b\u5225\u306e\u8a73\u7d30\u306b\u306f\u89e6\u308c\u307e\u305b\u3093\u3002<\/p>\n<p>\u306a\u304a\u3001Restek\u306e\u6a19\u6e96\u6eb6\u6db2\u306f\u6eb6\u6db2\u3068\u3057\u3066\u306e\u5b9f\u73fe\u53ef\u80fd\u6027\u3092\u8a55\u4fa1\u3057\u3001\u5316\u5408\u7269\u9593\u306e\u9069\u5408\u6027\u3092\u78ba\u8a8d\u3057\u305f\u3046\u3048\u3067\u8ca9\u58f2\u3057\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u3001\u591a\u6210\u5206\u7cfb\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u8907\u6570\u306e\u6eb6\u6db2\u3092\u6df7\u5408\u3057\u3066\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u3092\u8abf\u88fd\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u6df7\u5408\u5f8c\u306b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u30ed\u30b9\u3084\u672a\u77e5\u30d4\u30fc\u30af\u304c\u691c\u51fa\u3055\u308c\u305f\u5834\u5408\u306f\u3001\u8cfc\u5165\u3057\u305f\u5404\u6eb6\u6db2\u3092\u500b\u5225\u306b\u5206\u6790\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u5316\u5408\u7269\u9593\u3067\u4f55\u3089\u304b\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u751f\u3058\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n<h2>\u8ff7\u3063\u305f\u3068\u304d\u306fCoA\u3092\u78ba\u8a8d\uff5c\u6a19\u6e96\u6eb6\u6db2\u306e\u54c1\u8cea\u7ba1\u7406\u306e\u57fa\u672c<\/h2>\n<p>\u5224\u65ad\u306b\u8ff7\u3063\u305f\u3068\u304d\u306f\u3001\u5206\u6790\u8a3c\u660e\u66f8\uff08CoA\uff09\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002CoA\u306b\u306f\u63a8\u5968\u3055\u308c\u308b\u4fdd\u7ba1\u6761\u4ef6\u3068\u3001\u5149\u611f\u53d7\u6027\u3084\u5316\u5408\u7269\u4e0d\u9069\u5408\u6027\u306b\u95a2\u3059\u308b\u6ce8\u610f\u4e8b\u9805\u304c\u8a18\u8f09\u3055\u308c\u3066\u304a\u308a\u3001\u30e1\u30fc\u30ab\u30fc\u306f\u3053\u308c\u3089\u306e\u63a8\u5968\u4e8b\u9805\u3092\u88cf\u4ed8\u3051\u308b\u30c7\u30fc\u30bf\u3092\u4fdd\u6709\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n<h2>\u307e\u3068\u3081\uff1a\u6a19\u6e96\u6eb6\u6db2\u3092\u9069\u5207\u306b\u53d6\u308a\u6271\u3046\u305f\u3081\u306e\u30dd\u30a4\u30f3\u30c8<\/h2>\n<ul>\n<li><strong>\u4fdd\u7ba1\u6e29\u5ea6\u306f\u5316\u5408\u7269\u306e\u63ee\u767a\u6027\u3067\u5224\u65ad<\/strong>\uff1a\u63ee\u767a\u6027\u5316\u5408\u7269\u306f\u51b7\u51cd\u3001PAH\u3084\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u306a\u3069\u306f\u51b7\u8535\u3001Aroclor\u306e\u3088\u3046\u306a\u5316\u5408\u7269\u306f\u5ba4\u6e29<\/li>\n<li><strong>\u51b7\u51cd\u4fdd\u7ba1\u54c1\u306b\u6790\u51fa\u304c\u898b\u3089\u308c\u305f\u3089<\/strong>\uff1a\u5ba4\u6e29\u306b\u623b\u3057\u305f\u3046\u3048\u3067\u8d85\u97f3\u6ce2\u6d17\u6d44\u6a5f\u306710\u301c15\u5206\u51e6\u7406\u3057\u3001\u518d\u6eb6\u89e3\u3055\u305b\u3066\u304b\u3089\u4f7f\u7528<\/li>\n<li><strong>\u5149\u611f\u53d7\u6027\u5316\u5408\u7269\u306f\u8910\u8272\u30d0\u30a4\u30a2\u30eb\u3067\u4fdd\u8b77<\/strong>\uff1a\u9ec4\u8272\u706f\u4e0b\u3067\u306e\u4f5c\u696d\u3084\u8d64\u8272\u30ac\u30e9\u30b9\u5668\u5177\u306e\u4f7f\u7528\u3067\u5149\u3078\u306e\u66dd\u9732\u3092\u3055\u3089\u306b\u6291\u3048\u308b<\/li>\n<li><strong>\u6df7\u5408\u6db2\u3067\u6210\u5206\u30ed\u30b9\u30fb\u672a\u77e5\u30d4\u30fc\u30af\u304c\u51fa\u305f\u3089<\/strong>\uff1a\u5404\u6eb6\u6db2\u3092\u500b\u5225\u306b\u5206\u6790\u3057\u3001\u5316\u5408\u7269\u9593\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u78ba\u8a8d<\/li>\n<li><strong>\u5224\u65ad\u306b\u8ff7\u3063\u305f\u3089<\/strong>\uff1aCoA\u306b\u8a18\u8f09\u306e\u4fdd\u7ba1\u6761\u4ef6\u30fb\u6ce8\u610f\u4e8b\u9805\u3092\u5fc5\u305a\u78ba\u8a8d<\/li>\n<\/ul>\n\n<div class=\"rtk-callout\">\n<p>Restek\u63a8\u5968\u88fd\u54c1\uff1a<a href=\"https:\/\/www.restek.com\/c\/1102\/\" target=\"_blank\" rel=\"noopener\">Restek's Reference Standards<\/a>\uff08\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff1a\u6a19\u6e96\u6eb6\u6db2\uff09<\/p>\n<\/div>\n\n<h2>\u3088\u304f\u3042\u308b\u8cea\u554f<\/h2>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. \u6a19\u6e96\u6eb6\u6db2\u306f\u3069\u306e\u3088\u3046\u306b\u4fdd\u7ba1\u6e29\u5ea6\u3092\u9078\u3079\u3070\u3088\u3044\u3067\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u5316\u5408\u7269\u306e\u63ee\u767a\u6027\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002\u5869\u5316\u30d3\u30cb\u30eb\u304b\u3089\u30ca\u30d5\u30bf\u30ec\u30f3\u306e\u3088\u3046\u306a\u63ee\u767a\u6027\u5316\u5408\u7269\u306f\u51b7\u51cd\u3001PAH\u3084\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u306a\u3069\u306e\u4f4e\u63ee\u767a\u6027\u5316\u5408\u7269\u306f\u51b7\u8535\u3001Aroclor\u306e\u3088\u3046\u306a\u5316\u5408\u7269\u306f\u5ba4\u6e29\u3067\u306e\u4fdd\u7ba1\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u8a73\u3057\u304f\u306fCoA\u306e\u8a18\u8f09\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n<\/details>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. \u51b7\u51cd\u4fdd\u7ba1\u3057\u3066\u3044\u305f\u6a19\u6e96\u6eb6\u6db2\u306b\u6fc1\u308a\u3084\u6c88\u6bbf\u304c\u898b\u3089\u308c\u308b\u5834\u5408\u306f\u3069\u3046\u3059\u308c\u3070\u3088\u3044\u3067\u3059\u304b\uff1f<\/h3><\/summary>\n<p>\u5ba4\u6e29\u306b\u623b\u3057\u305f\u5f8c\u3001\u8d85\u97f3\u6ce2\u6d17\u6d44\u6a5f\u306710\u301c15\u5206\u51e6\u7406\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u51b7\u51cd\u4fdd\u7ba1\u4e2d\u306b\u6790\u51fa\u3057\u305f\u5316\u5408\u7269\u3092\u6eb6\u6db2\u4e2d\u306b\u518d\u6eb6\u89e3\u3055\u305b\u308b\u3053\u3068\u3067\u3001\u5206\u6790\u6642\u306e\u691c\u51fa\u6f0f\u308c\u3084\u6fc3\u5ea6\u306e\u4f4e\u4e0b\u3092\u9632\u3052\u307e\u3059\u3002<\/p>\n<\/details>\n\n<details class=\"rtk-faq\">\n<summary><h3>Q. \u8907\u6570\u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u6df7\u5408\u3057\u305f\u969b\u306b\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u691c\u51fa\u3055\u308c\u306a\u304b\u3063\u305f\u308a\u672a\u77e5\u306e\u30d4\u30fc\u30af\u304c\u51fa\u305f\u308a\u3057\u305f\u5834\u5408\u306f\uff1f<\/h3><\/summary>\n<p>\u5316\u5408\u7269\u9593\u3067\u76f8\u4e92\u4f5c\u7528\u304c\u751f\u3058\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u8cfc\u5165\u3057\u305f\u5404\u6eb6\u6db2\u3092\u500b\u5225\u306b\u5206\u6790\u3057\u3001\u6df7\u5408\u524d\u5f8c\u306e\u7d50\u679c\u3092\u6bd4\u8f03\u3059\u308b\u3053\u3068\u3092\u304a\u3059\u3059\u3081\u3057\u307e\u3059\u3002<\/p>\n<\/details>\n\n<h2>\u8457\u8005<\/h2>\n<p>Chas Simons<\/p>\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Readers of the blog have been presented with a wealth of information on for their GC columns, LC columns, detectors, syringes, carrier gases, TO-Canisters, and the list go on. What&rsquo;s missing? Analytical Reference Standards. Although not all reference standards have&#8230;<\/p>\n","protected":false},"author":73,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2399,2374],"resource-technique":[],"ppma_author":[583],"class_list":["post-99364","post","type-post","status-publish","format-standard","hentry","category-blogs","product-library-liquid-reference-standards","product-library-reference-standard-products"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"product-library":[{"value":2399,"label":"Liquid Reference Standards"},{"value":2374,"label":"Reference Standard Products"}]},"featured_image_src_large":false,"author_info":{"display_name":"Ayumi Suzuki","author_link":"https:\/\/discover.restek.com\/ja\/author\/ayumi-suzuki\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":2815,"user_id":0,"is_guest":1,"slug":"chas-simons","display_name":"Chas Simons","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/99364","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/73"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=99364"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/99364\/revisions"}],"predecessor-version":[{"id":99844,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/99364\/revisions\/99844"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=99364"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=99364"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=99364"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=99364"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=99364"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=99364"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=99364"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=99364"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=99364"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}