应用笔记

GC/MS Analysis of Melamine and Cyanuric Acid Below 1 µg/g in Infant Formula

29 Oct 2020

feature FFAN1137

Abstract

The establishment of a 1 μg/g safety threshold for melamine in infant foods has led to a need for sensitive methods. Here, we established GC/MS conditions for highly reproducible analyses and evaluated the effectiveness of both solvent-based and matrix-matched standards. Using this method, melamine and cyanuric acid were reliably detected at and below 1 μg/g in infant formula.

Introduction

Reports linking the presence of melamine in pet food and infant formula to illnesses and deaths have led to the recall of a wide variety of tainted food products and to calls for stricter product testing. Melamine is not considered toxic alone at low doses; however, the observed toxicity has been attributed to melamine exposure in the presence of cyanuric acid. In combination, these compounds form insoluble crystals in the kidneys, causing illness and eventual renal failure. Melamine is not a legal food additive; it is a nitrogen-rich industrial compound used for plastics, flame-resistant products, and some cleaning agents. However, melamine and related byproducts have been added illegally to food products in order to falsely represent the amount of protein present, since protein level in many products is determined using nonspecific assays for nitrogen content (Figure 1).

Figure 1: Melamine and related compounds are rich in nitrogen and have been used to misrepresent protein levels in some food products.
figure article FFAN1137A 01

In response to the need for more rigorous melamine and cyanuric acid testing, the U.S. Food and Drug Administration (FDA) has set three different commodity-based minimum reporting levels (MRLs): 10 μg/g for pet food, 2.5 μg/g for human food, and 1 μg/g for infant formula [1,2]. These limits place stringent demands on the analyst to demonstrate adequate instrument sensitivity. The following work was performed to establish conditions for melamine analysis down to 1 μg/g in infant formula and is based on the FDA method, GC-MS Screen for the Presence of Melamine, Ammeline, Ammelide, and Cyanuric Acid [1]. Refer to the FDA method for overall experimental design and semiquantitative calculations.

Procedure

Sample Preparation

All solutions were made using a 1000 μg/mL (each compound) mixed stock solution of melamine, cyanuric acid, ammeline, and ammelide (cat.# 33253). Working standard solutions were then prepared at 1 μg/mL, 10 μg/mL, and 100 μg/mL in extraction solvent (10/40/50 diethylamine/water/acetonitrile). The 10 μg/mL working solution was used to fortify control infant formula at 0.5 μg/g, 1 μg/g, and 5 μg/g (dry formula was prepared according to label instructions prior to fortification). These matrix spike levels were chosen to demonstrate method performance at the MRL for infant formula (1 μg/g) and the MRL for adult human food commodities (2.5 μg/g). High and low standards were also prepared from the working solutions. Standards were prepared in solvent alone and also in extracted matrix at concentrations equivalent to sample fortification levels (0.0125 μg/mL, 0.0249 μg/mL, and 0.123 μg/mL) in order to evaluate possible matrix effects and to determine which technique would yield the most reliable GC/MS data.

The extraction procedure was performed as follows. Multiple 0.5 g matrix samples were prepared in 50 mL centrifuge tubes (cat.# 26227) and fortified if necessary (matrix control blanks were not spiked). After fortification, 20 mL of extraction solvent (10/40/50 diethylamine/water/acetonitrile) was added to each tube, and the samples were then sonicated for 30 minutes. Following sonication, the samples were centrifuged for 10 minutes to pellet particulate matter. The supernatant was then filtered through a 0.45 μm nylon filter (cat.# 26147) to remove any remaining particles and 200 μL aliquots of the resulting extracts were transferred to autosampler vials for derivatization.

Derivatization

Aliquots of standard (50 μL solvent-based, 200 μL matrix-based) and sample extracts (200 μL) were evaporated to dryness at 70 °C with nitrogen gas. Derivatization was performed as follows: 200 μL pyridine, 200 μL BSTFA with 1% TMCS (cat.# 35606), and 100 μL of benzoguanamine (internal standard, available as a custom standard) were added to each vial. Vials were shaken or vortexed for 10 minutes and then incubated at 70 °C for 45 minutes. Derivatization was also tested using 50 μL of BSTFA with 1% TMCS in attempt to minimize instrument contamination from excess derivatization material [3]. Samples processed with the reduced amount of reagent were not completely derivatized; therefore, the FDA method for derivatization using 200 μL of reagent was followed [1].

Analysis

Analyses were performed on a Shimadzu QP 2010 Plus gas chromatograph mass spectrometer (GC/MS) equipped with an AOC 20i+s auto injector and sampler. An Rxi-5Sil MS (30 m x 0.25 mm ID x 0.25 μm) column with a 5 m Integra-Guard integrated guard column (cat.# 13623-124) was used for the analysis. The integrated guard column was chosen since it protects the analytical column from matrix contamination, thus extending column lifetime, and prevents the possibility of leaks at a press-fit connection.

A splitless liner packed with wool (cat.# 22286-200.1) was used to help vaporize the compounds and also to further protect the column by trapping any nonvolatile compounds. GC conditions are shown in Figure 2; mass spectrometer conditions follow and are shown in Table I. The mass spectrometer was operated in SIM acquisition mode with selected ions for each analyte of interest. The transfer line temperature was set at 290 °C and the ion source temperature at 190 °C. The filament delay was set at 8.1 minutes and the dwell time for each ion was 0.15 seconds, giving a total run time of 18.67 minutes.

Calculations were performed using relative response factors as described in the FDA method [1]. Samples were quantified using both solvent-based and matrix-matched quantification standards in order to assess matrix effect and determine which procedure was more effective for infant formula.

Results

This method successfully detected melamine and cyanuric acid to the MRLs required for routine analysis of infant formula and human foods. Highly reproducible chromatographic separation was achieved (Figure 2) and was critical for compound identification, since several quantitation ions were also found in other peaks. Matrix interference was a significant issue for the analysis of ammelide and ammeline at lower concentrations.

Quantitation Ions and Importance of Retention Data

The quantitation ions given in the method were used. However, several of these ions (including m/z 344 and 345) were shared among analytes and were also observed for many of the peaks in samples and derivatizing reagent blanks. This resulted in heavy reliance on chromatographic retention time data for peak identification (in conjunction with confirmation of the ion ratios listed in Table I). The FDA method requires retention times to be within 0.05 minutes for compound identification [1]. This was easily achieved using the Rxi-5Sil MS column, which produced highly reproducible results, even after the approximately 150 injections made during testing (Table II).

Table I: MS conditions (SIM mode).

CompoundtR (min)Quant. ionQual. ionQual. ionQual. ion
Cyanuric acid10.23345 (100)*330 (36)346 (30)347 (15)
Ammelide11.07344 (100)329 (58)345 (30)330 (16)
Ammeline11.76328 (100)343 (79)329 (29)344 (24)
Melamine12.31327 (100)342 (53)328 (30)343 (17)
Benzoguanamine14.54316 (100331 (68)332 (20)330 (9)
*Expected relative ion ratios from FDA method.

Table II: Retention time is critical to accurate peak identification. Highly reproducible results were achieved using an Rxi-5Sil MS column (n=3).

CompoundRetention time (min)
 0.5 μg/g1 μg/g5 μg/g
Cyanuric acid10.26 ± 0.0510.23 ± 0.000610.23 ± 0.001
Ammelide11.08 ± 0.00311.07 ± 0.00211.08 ± 0.003
Ammeline11.76 ± 0.00111.76 ± 0.00311.76 ± 0.002
Melamine12.31 ± 0.00212.31 ± 0.00012.31 ± 0.004
Benzoguanamine14.54 ± 0.00214.54 ± 0.00114.54 ± 0.002
Figure 2: Analysis of melamine and related compounds in infant formula (1 μg/g MRL spike level).

A. Solvent-only standard (0.01 μg/mL injection concentration)

Analysis of Melamine and Related Compounds on Rxi-5Sil MS

GC_FF01094

Peaks

PeakstR (min)Quant. IonQual. IonQual.IonQual. Ion
1.Cyanuric acid10.238345330346347
2.Ammelide11.090344329345330
3.Ammeline11.770328343329344
4.Melamine12.318327342328343
5.Benzoguanamine14.553316331332330

Conditions

ColumnRxi-5Sil MS w/5 m Integra-Guard column, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623-124)
Standard/Sample
Melamine and related analogs stock standard
Benzoguanamine
Conc.:0.01 µg/mL as tri-TMS derivatives
Injection
Inj. Vol.:1.0 µL splitless (hold 1 min)
Liner:3.5 mm Gooseneck Splitless w/Wool
Inj. Temp.:280 °C
Oven
Oven Temp.:75 °C to 320 °C at 15 °C/min (hold 4 min)
Carrier GasHe, constant flow
Flow Rate:1 mL/min
DetectorMS
Mode:SIM
Transfer Line Temp.:290 °C
Ionization Mode:EI
InstrumentShimadzu 2010 GC & QP2010+ MS
NotesStandards cat.# 33253 and cat.# 33251 and liner cat.# 22286-200.1 were used to produce this chromatogram, but they have since been discontinued. We recommend cat.# 23336 as an alternative liner. For assistance choosing a replacement for this application, contact Restek Technical Service or your local Restek representative.
– – – – – –
all method ions in table, only quantification ions were plotted

B. Matrix spike (0.01 μg/mL injection concentration)

Analysis of Melamine and Related Compounds in Infant Formula on Rxi-5Sil MS

GC_FF01095

Peaks

PeakstR (min)Quant. IonQual. IonQual.IonQual. Ion
1.Cyanuric acid10.258345330346347
2.Ammelide11.073344329345330
3.Ammeline11.760328343329344
4.Melamine12.328327342328343
5.Benzoguanamine14.538316331332330

Conditions

ColumnRxi-5Sil MS w/5 m Integra-Guard column, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623-124)
Standard/Sample
Infant formula fortified at 1 μg/g with melamine and related analogs stock standard
Benzoguanamine
Conc.:0.01 µg/mL as tri-TMS derivatives
Injection
Inj. Vol.:1.0 µL splitless (hold 1 min)
Liner:3.5 mm Gooseneck Splitless w/Wool
Inj. Temp.:280 °C
Oven
Oven Temp.:75 °C to 320 °C at 15 °C/min (hold 4 min)
Carrier GasHe, constant flow
Flow Rate:1 mL/min
DetectorMS
Mode:SIM
Transfer Line Temp.:290 °C
Ionization Mode:EI
InstrumentShimadzu 2010 GC & QP2010+ MS
NotesStandards cat.# 33253 and cat.# 33251 and liner cat.# 22286-200.1 were used to produce this chromatogram, but they have since been discontinued. We recommend cat.# 23336 as an alternative liner. For assistance choosing a replacement for this application, contact Restek Technical Service or your local Restek representative.
– – – – – –
all method ions in table, only quantification ions were plotted

Recovery of Target Compounds

Recovery data can be determined using solvent-based standards (no matrix) or matrix-matched standards (prepared in matrix extract and then derivatized). Since some matrices provide an analyte-protecting effect that results in an increased response compared to an identical analysis with solvent-based standards, we evaluated both methods here [4,5,6]. Recovery values using solvent-based standards varied from 50 to 250%, compared to the 81 to 143% recoveries shown in Table III, which were determined using matrix-matched standards. Though this method is not intended for true quantitation, recoveries based on matrix-matched standards indicate that determining melamine and cyanuric acid at different minimum reporting levels is possible, even below the 1 μg/g MRL required for infant formula.

Table III: Recovery of melamine and related compounds from spiked infant formula using matrix-matched standards (n = 3).

 μg/g Detected% Recovery (mean±std.dev.)
0.5 μg/g fortification  
Cyanuric acid0.481±29
AmmelideMIMI
AmmelineMIMI
Melamine0.4285±35
1 μg/g fortification  
Cyanuric acid1.3131±17
Ammelide1.3132±20
Ammeline MI MI
Melamine1.3132±57
5 μg/g fortification  
Cyanuric acid7.2143±46
Ammelide4.997±18
Ammeline5.3106±20
Melamine4.386±34
MI= matrix interference prevented accurate integration.

Matrix Interference

As shown in Table III, ammelide and ammeline could not be integrated reliably below the MRL due to partial coelution with a matrix compound that had isobaric interferences. The same effect was observed for ammeline at 1 μg/g. Accurate integration was not possible since the ion ratios of the target analyte did not align with those expected based on known spectra or spectra of standards determined on the same system. While this method was optimized for melamine and cyanuric acid, the matrix interference seen for the other compounds illustrates the importance of evaluating and minimizing matrix carryover, especially when analyzing a new matrix. In this work, derivatizing reagent blanks were analyzed between each sample to ensure there was no carryover to subsequent injections.

Conclusion

Analysis of melamine and related compounds in infant formula is challenging since it has the lowest MRL of all commodities, and also because it is rich in sugars, which derivatize and chromatograph easily, thus increasing the potential for significant interferences. While this method successfully determined melamine and cyanuric acid to the MRLs required for routine analysis, coelutions complicated the analysis of ammelide and ammeline. Reliable retention time identification was critical for compound identification and the Rxi-5Sil MS column used here detected target analytes reproducibly and thus is recommended for GC/MS analysis of melamine. In addition, this column includes an Integra-Guard integrated guard column, which extends analytical column lifetime without the risk of leaks that can occur with manually connected guards.

References

[1] J. Litzau, G. Mercer, K. Mulligan, Laboratory Information Bulletin: LIB 4423: Melamine and Related Compounds, GC-MS screen for the presence of melamine, ammeline, ammelide, and cyanuric acid, October 2008. https://www.fda.gov/food/laboratory-methods-food/laboratory-information-bulletin-lib-4423-melamine-and-related-compounds.
[2] US Food and Drug Administration, May 2007, GC-MS Method for Screening and Confirmation of Melamine and Related Analogs, version 2, http://www.fda.gov/cvm/GCMSscreen.htm.
[3] M. Long, J. Kowalski, Advantage 2008.01, 14-15 (2008).
[4] C.F. Poole, Matrix-induced response enhancement in pesticide residue analysis by gas chromatography, J. Chromatogr. A 1158 (2007) 241-250. https://www.ncbi.nlm.nih.gov/pubmed/17241638.
[5] T. Cajka, K. Maštovská, S.J. Lehotay and J. Hajšlová, Use of automated direct sample introduction with analyte protectants in the GC–MS analysis of pesticide residues, J. Sep. Sci. 28, 1048-1060 (2005). https://onlinelibrary.wiley.com/doi/epdf/10.1002/jssc.200500050.
[6] K. Maštovská, S.J. Lehotay and M. Anastassiades, Combination of analyte protectants to overcome matrix effects in routine GC analysis of pesticide residues in food matrixes, Anal. Chem. 77, 8129-8137 (2005). https://pubs.acs.org/doi/pdf/10.1021/ac0515576.

相关产品


13 mm Syringe Filter, 0.45 µm, Nylon, Pink, 100-pk.
Silylation Derivatization Reagent, BSTFA w/1% TMCS (N,O-bis[Trimethylsilyltrifluoroacetamide] w/1% Trimethylchlorosilane), 10×1 g Vials, 10-pk.
Rxi-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm with 5 m Integra-Guard Column
Topaz, Single Taper Inlet Liner, 3.5 mm x 5.0 x 95, for Shimadzu 17A, 2010, 2014, and 2030 GCs, w/Quartz Wool Near Bottom, Premium Deactivation, 5-pk.

作者

  • Restek Corporation

    Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions.

    查阅所有文章
FFAN1137
版本: A