{"id":102811,"date":"2026-06-30T11:00:19","date_gmt":"2026-06-30T11:00:19","guid":{"rendered":"https:\/\/discover.restek.com\/?p=102811"},"modified":"2026-09-09T09:40:08","modified_gmt":"2026-09-09T09:40:08","slug":"a-two-in-one-solution-for-pfas-spe-sample-preparation","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles\/a-two-in-one-solution-for-pfas-spe-sample-preparation\/","title":{"rendered":"PFAS SPE\u6837\u54c1\u5236\u5907\u7684\u4e8c\u5408\u4e00\u89e3\u51b3\u65b9\u6848"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>\u5355\u652f\u67f1\u7ba1\u540c\u65f6\u88c5\u586b WAX \u548cGCB\u586b\u6599\uff0c\u7b80\u5316\u5de5\u4f5c\u6d41\u7a0b<\/li>\n\n\n\n<li>\u51fa\u5382\u9884\u88c5\u7684\u52a9\u6ee4\u5242\u8282\u7701\u65f6\u95f4\u5e76\u9632\u6b62\u5835\u585e<\/li>\n\n\n\n<li>\u8d85\u7eaf\u51c0\u5438\u9644\u5242\u786e\u4fdd\u8fbe\u5230\u65b9\u6cd5\u68c0\u6d4b\u9650\uff08Method Detection Limit, MDL\uff09\uff0c\u5e76\u4fdd\u8bc1\u5206\u6790\u7ed3\u679c\u7684\u4e00\u81f4\u6027<\/li>\n<\/ul>\n\n\n\n<ul style=\"margin-top:var(--wp--preset--spacing--50);margin-bottom:var(--wp--preset--spacing--50)\" class=\"wp-block-list\">\n<li>\u5355\u652f\u67f1\u7ba1\u540c\u65f6\u88c5\u586b WAX \u548cGCB\u586b\u6599\uff0c\u7b80\u5316\u5de5\u4f5c\u6d41\u7a0b<\/li>\n\n\n\n<li>\u51fa\u5382\u9884\u88c5\u7684\u52a9\u6ee4\u5242\u8282\u7701\u65f6\u95f4\u5e76\u9632\u6b62\u5835\u585e<\/li>\n\n\n\n<li>\u8d85\u7eaf\u51c0\u5438\u9644\u5242\u786e\u4fdd\u8fbe\u5230\u65b9\u6cd5\u68c0\u6d4b\u9650\uff08Method Detection Limit, MDL\uff09\uff0c\u5e76\u4fdd\u8bc1\u5206\u6790\u7ed3\u679c\u7684\u4e00\u81f4\u6027<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-top:0px;margin-bottom:0px\"><strong>\u4f7f\u7528\u53cc\u5c42 Resprep PFAS \u5c0f\u67f1\u7cbe\u7b80 PFAS \u6837\u54c1\u524d\u5904\u7406<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u4e8e\u975e\u996e\u7528\u6c34\u3001\u56fa\u4f53\u3001\u751f\u7269\u56fa\u4f53\u548c\u7ec4\u7ec7\u7b49\u590d\u6742\u6837\u54c1\u57fa\u8d28\u4e2d\u7684\u75d5\u91cf\u5168\u6c1f\u53ca\u591a\u6c1f\u70f7\u57fa\u7269\u8d28\uff08Per- and Polyfluoroalkyl Substances, PFAS\uff09\u5206\u6790\uff0c\u6709\u6548\u7684\u6837\u54c1\u524d\u5904\u7406\u81f3\u5173\u91cd\u8981\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u901a\u5e38\u91c7\u7528\u56fa\u76f8\u8403\u53d6\uff08Solid Phase Extraction, SPE\uff09\uff0c\u4f46\u5982\u679c\u5b58\u5728\u80cc\u666f PFAS\uff0c\u6216\u6837\u54c1\u6210\u5206\u5835\u585e SPE \u67f1\u7ba1\uff0c\u5219\u96be\u4ee5\u83b7\u5f97\u826f\u597d\u7ed3\u679c\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EPA 1633\u65b9\u6cd5\u5148\u91c7\u7528\u586b\u6709\u73bb\u7483\u6bdb\u7684WAX\u5c0f\u67f1\u8fdb\u884c\u57fa\u8d28\u63d0\u53d6\uff0c\u968f\u540e\u901a\u8fc7GCB\u5c0f\u67f1\u8fdb\u884c\u51c0\u5316\u3002\u8bb8\u591a\u5b9e\u9a8c\u5ba4\u6b63\u91c7\u7528\u78b3\u8403\u53d6\u67f1\u66ff\u4ee3 dGCB\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c3d\u7ba1\u8be5\u65b9\u6cd5\u53ef\u884c\uff0c\u4f46\u9700\u8981\u4e24\u652fSPE\u5c0f\u67f1\u4e14\u9700\u624b\u52a8\u586b\u88c5\u73bb\u7483\u6bdb\uff0c\u4e24\u6b65\u64cd\u4f5c\u4e0d\u4ec5\u589e\u52a0\u4e86\u989d\u5916\u7684\u65f6\u95f4\u548c\u64cd\u4f5c\u590d\u6742\u6027\uff0c\u8fd8\u589e\u52a0\u4e86\u6837\u54c1\u91c7\u96c6\u548c\u524d\u5904\u7406\u8fc7\u7a0b\u4e2d\u542bPFAS\u6750\u6599\u5f15\u8d77\u4ea4\u53c9\u6c61\u67d3\u7684\u98ce\u9669\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns has-background is-layout-flex wp-container-core-columns-is-layout-9d3e8bdf wp-block-columns-is-layout-flex\" style=\"border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-left-radius:10px;border-bottom-right-radius:10px;background-color:#fcf3e2;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-right:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:70%\">\n<h3 class=\"wp-block-heading has-text-color has-link-color wp-elements-1\" style=\"color:#067f9e;font-size:24px\">\u4f7f\u7528\u5e26\u52a9\u6ee4\u5242\u7684 Resprep PFAS \u5c0f\u67f1\uff0c\u7b80\u5316\u60a8\u7684\u6837\u54c1\u524d\u5904\u7406\u6d41\u7a0b<\/h3>\n\n\n<style>.wp-block-kadence-advancedbtn.kt-btns102811_30eb79-c2, .site .entry-content .wp-block-kadence-advancedbtn.kt-btns102811_30eb79-c2, .wp-block-kadence-advancedbtn.kb-btns102811_30eb79-c2, .site .entry-content .wp-block-kadence-advancedbtn.kb-btns102811_30eb79-c2{margin-top:var(--global-kb-spacing-xs, 1rem);margin-right:0px;margin-bottom:0px;margin-left:0px;}.wp-block-kadence-advancedbtn.kb-btns102811_30eb79-c2{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns102811_30eb79-c2 .kt-button{font-weight:normal;font-style:normal;}.kt-btns102811_30eb79-c2 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns102811_30eb79-c2 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns102811_30eb79-c2 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns102811_30eb79-c2 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns102811_30eb79-c2 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns102811_30eb79-c2 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns102811_30eb79-c2 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns102811_30eb79-c2\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn102811_28475c-64.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn102811_28475c-64.kb-button{background:#067f9e;border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn102811_28475c-64.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn102811_28475c-64.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn102811_28475c-64 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"#filteraid\"><span class=\"kt-btn-inner-text\">\u4e86\u89e3\u66f4\u591a<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"286\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-cartridge-alone.png\" alt=\"\" class=\"wp-image-97780\" style=\"width:300px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-cartridge-alone.png 800w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-cartridge-alone-300x107.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-cartridge-alone-768x275.png 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Resprep PFAS \u53cc\u5c42\u5c0f\u67f1\u662f\u66f4\u7b80\u5355\u7684\u89e3\u51b3\u65b9\u6848<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u91c7\u7528\u53cc\u5c42\u586b\u6599\u7684Resprep PFAS\u8403\u53d6\u5c0f\u67f1\uff0c\u53ef\u663e\u8457\u7b80\u5316PFAS\u6837\u54c1\u524d\u5904\u7406\u6d41\u7a0b\u3002\u8be5\u8403\u53d6\u67f1\u5c06WAX\u8403\u53d6\u548cGCB\u51c0\u5316\u5408\u4e8c\u4e3a\u4e00\uff0c\u6709\u52a9\u4e8e\u964d\u4f4e\u6c61\u67d3\u98ce\u9669\u3002\u5728\u6b64\u5feb\u901f\u7b80\u4fbf\u7684\u5de5\u4f5c\u6d41\u7a0b\u4e2d\uff0c\u5c0f\u67f1\u5185\u88c5\u586b\u7684\u8d85\u6d01\u51c0\u7684WAX\u5438\u9644\u5242\u548cGCB\u5438\u9644\u5242\uff0c\u53ef\u786e\u4fdd\u6ee1\u8db3\u996e\u7528\u6c34\u53ca\u5176\u4ed6\u6837\u54c1\u4e2dPFAS\u5206\u6790\u7684\u65b9\u6cd5\u6027\u80fd\u8981\u6c42\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b64\u5916\uff0c\u53ef\u9009\u914d\u7684\u5de5\u5382\u9884\u88c5\u52a9\u6ee4\u5242\uff0c\u7701\u53bb\u4e86\u6c34\u6837\u5904\u7406\u8fc7\u7a0b\u4e2d\u624b\u52a8\u586b\u88c5\u73bb\u7483\u6bdb\u7684\u6b65\u9aa4\uff0c\u4ece\u800c\u8282\u7701\u4e86\u65f6\u95f4\u5e76\u6d88\u9664\u4e86\u64cd\u4f5c\u5dee\u5f02\u6027\u3002\u8fd9\u79cd\u5373\u7528\u578b\u89e3\u51b3\u65b9\u6848\u53ef\u6709\u6548\u9632\u6b62\u5835\u585e\uff0c\u5373\u4f7f\u9762\u5bf9\u57fa\u8d28\u8f83\u810f\u7684\u6837\u54c1\uff0c\u4e5f\u53ef\u901a\u8fc7\u5355\u6b21\u8403\u53d6\u5feb\u901f\u5b8c\u6210\u5904\u7406\u3002<\/p>\n\n\n<style>.kb-image102811_7570f6-8d .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image102811_7570f6-8d\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"513\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-01-1024x513.jpg\" alt=\"\" class=\"kb-img wp-image-24040\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-01-1024x513.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-01-300x150.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-01-768x385.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-01-1536x770.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u5feb\u901f\u4e14\u4e00\u81f4\u5730\u6ee1\u8db3\u6027\u80fd\u8981\u6c42<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Resprep PFAS\u53cc\u5c42\u5c0f\u67f1\u4e13\u4e3a\u5e2e\u52a9\u5b9e\u9a8c\u5ba4\u6ee1\u8db3 PFAS \u6027\u80fd\u8981\u6c42\u800c\u5f00\u53d1\uff0c\u5185\u542b\u8d85\u7eaf\u51c0\u3001\u9ad8\u54c1\u8d28\u7684 WAX \u548cGCB\u586b\u6599\uff0c\u53ef\u5b9e\u73b0\u6709\u6548\u7684\u8403\u53d6\u4e0e\u51c0\u5316\u3002\u6bcf\u4e00\u6279 WAX \u5438\u9644\u5242\u5747\u68c0\u6d4b\u4e86EPA 1633\u65b9\u6cd5\u4e2d\u5f85\u6d4bPFAS\u7684\u7a7a\u767d\u503c\uff0c\u4ee5\u8bc1\u660e\u5176\u6d01\u51c0\u5ea6\u5e76\u786e\u4fdd\u4e0d\u5f15\u5165\u80cc\u666f PFAS\u3002\u6b64\u5916\uff0c\u9ad8\u6027\u80fd\u7684 GCB\u5438\u9644\u5242\u8f83\u5176\u4ed6\u78b3\u6750\u6599\u80fd\u63d0\u4f9b\u66f4\u6709\u6548\u3001\u66f4\u4e00\u81f4\u7684\u51c0\u5316\u3002\u4e24\u79cd\u586b\u6599\u96c6\u6210\u4e8e\u5355\u652fSPE\u5c0f\u67f1\uff0c\u4f7f\u6837\u54c1\u524d\u5904\u7406\u66f4\u4e3a\u5feb\u901f\uff0c\u5e76\u83b7\u5f97\u6d01\u51c0\u7684\u8403\u53d6\u6db2\u548c\u4f18\u5f02\u7684\u5206\u6790\u6027\u80fd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e24\u79cd\u5438\u9644\u5242\u5408\u5e76\u5728\u540c\u4e00\u8403\u53d6\u67f1\u4e2d\uff0c\u53ef\u4f7f PFAS \u6837\u54c1\u5236\u5907\u901f\u5ea6\u5927\u5927\u52a0\u5feb\u3002\u5f53\u4e0e LC-MS \u6216\u9ad8\u5206\u8fa8\u8d28\u8c31\u8054\u7528\u8fdb\u884c\u6570\u636e\u5206\u6790\u65f6\uff0c\u53ef\u5feb\u901f\u83b7\u5f97\u6d01\u51c0\u7684\u63d0\u53d6\u7269\u548c\u51fa\u8272\u7684\u5206\u6790\u7ed3\u679c\uff08\u56fe 1 \u548c\u8868 I\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fe 1\uff1aResprep PFAS \u5c0f\u67f1\u53ef\u5b9e\u73b0\u6709\u6548\u7684 SPE \u6837\u54c1\u524d\u5904\u7406\uff0c\u8f83\u5206\u7acb\u7684\u8403\u53d6\u4e0e\u51c0\u5316\u6d41\u7a0b\u66f4\u5feb\u901f\u3001\u66f4\u6613\u7528<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 1\uff1aResprep PFAS \u5c0f\u67f1\u53ef\u5b9e\u73b0\u6709\u6548\u7684 SPE \u6837\u54c1\u524d\u5904\u7406\uff0c\u8f83\u5206\u7acb\u7684\u8403\u53d6\u4e0e\u51c0\u5316\u6d41\u7a0b\u66f4\u5feb\u901f\u3001\u66f4\u6613\u7528<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0599.png\" alt=\"EPA Method 1633 PFAS on Force C18 (50 x 2.1 mm) Extracted with Resprep PFAS SPE\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0599<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor 1<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><th style=\"text-align: center;width: 75px\">Precursor 2<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4- 13C3]butanoic acid (13C3-PFBA)<\/td><td class=\"oth\">1.485<\/td><td class=\"oth\">5<\/td><td class=\"oth\">216<\/td><td class=\"oth\">172<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4- 13C4]butanoic acid (13C4-PFBA)<\/td><td class=\"oth\">1.487<\/td><td class=\"oth\">10<\/td><td class=\"oth\">217<\/td><td class=\"oth\">172<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanoic acid (PFBA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-22-4\/Perfluorobutanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanoic acid (PFBA)<\/a><\/td><td class=\"oth\">1.489<\/td><td class=\"oth\">10<\/td><td class=\"oth\">213<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoro-3-methoxypropanoic acid (PFMPA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/377-73-1\/Perfluoro-3-methoxypropanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoro-3-methoxypropanoic acid (PFMPA)<\/a><\/td><td class=\"oth\">2.007<\/td><td class=\"oth\">5<\/td><td class=\"oth\">229<\/td><td class=\"oth\">85<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\">3-Perfluoropropyl propanoic acid (3:3FTCA)<\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">12.5<\/td><td class=\"oth\">241<\/td><td class=\"oth\">177<\/td><td class=\"oth\">117<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,5- 13C5]pentanoic acid (13C5-PFPeA)<\/td><td class=\"oth\">2.765<\/td><td class=\"oth\">5<\/td><td class=\"oth\">268<\/td><td class=\"oth\">223<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoropentanoic acid (PFPeA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2706-90-3\/Perfluoropentanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoropentanoic acid (PFPeA)<\/a><\/td><td class=\"oth\">2.768<\/td><td class=\"oth\">5<\/td><td class=\"oth\">263<\/td><td class=\"oth\">219<\/td><td class=\"oth\">69<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">Perfluorobutane sulfonate (PFBS)<\/td><td class=\"oth\">3.006<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">299<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\">Sodium perfluoro-1-[2,3,4- 13C3]butanesulfonate (13C3-PFBS)<\/td><td class=\"oth\">3.007<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">302<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\">Perfluoro-4-methoxybutanoic acid (PFMBA)<\/td><td class=\"oth\">3.071<\/td><td class=\"oth\">5<\/td><td class=\"oth\">279<\/td><td class=\"oth\">85<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoro(2-ethoxyethane)sulfonic acid (PFEESA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113507-82-7\/Perfluoro(2-ethoxyethane)sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluoro(2-ethoxyethane)sulfonic acid (PFEESA)<\/a><\/td><td class=\"oth\">3.333<\/td><td class=\"oth\">5<\/td><td class=\"oth\">315<\/td><td class=\"oth\">135<\/td><td class=\"oth\">83<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\">Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)<\/td><td class=\"oth\">3.493<\/td><td class=\"oth\">5<\/td><td class=\"oth\">295<\/td><td class=\"oth\">201<\/td><td class=\"oth\">85<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluorohexane sulfonate (4:2 FTS)<\/td><td class=\"oth\">3.545<\/td><td class=\"oth\">10<\/td><td class=\"oth\">327<\/td><td class=\"oth\">307<\/td><td class=\"oth\">81<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\">Sodium 1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluoro-1-[1,2- 13C2]hexane sulfonate (13C2-4:2FTS)<\/td><td class=\"oth\">3.55<\/td><td class=\"oth\">5<\/td><td class=\"oth\">329<\/td><td class=\"oth\">81<\/td><td class=\"oth\">309<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanoic acid (PFHxA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-24-4\/Perfluorohexanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanoic acid (PFHxA)<\/a><\/td><td class=\"oth\">3.608<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">313<\/td><td class=\"oth\">269<\/td><td class=\"oth\">119<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,6- 13C2]hexanoic acid (13C2-PFHxA)<\/td><td class=\"oth\">3.609<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">315<\/td><td class=\"oth\">270<\/td><td class=\"oth\">119<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,6- 13C5]hexanoic acid (13C5-PFHxA)<\/td><td class=\"oth\">3.61<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">318<\/td><td class=\"oth\">273<\/td><td class=\"oth\">120<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\">Perfluoropentane sulfonate (PFPeS)<\/td><td class=\"oth\">3.718<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">349<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\">2,3,3,3-Tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy13C3-propanoic acid (13C3-HFPO-DA)<\/td><td class=\"oth\">3.79<\/td><td class=\"oth\">10<\/td><td class=\"oth\">287<\/td><td class=\"oth\">169<\/td><td class=\"oth\">185<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexafluoropropylene oxide (HFPO-DA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13252-13-6\/Hexafluoropropylene oxide\" target=\"_blank\" rel=\"noopener\">Hexafluoropropylene oxide (HFPO-DA)<\/a><\/td><td class=\"oth\">3.795<\/td><td class=\"oth\">10<\/td><td class=\"oth\">285<\/td><td class=\"oth\">169<\/td><td class=\"oth\">185<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroheptanoic acid (PFHpA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-85-9\/Perfluoroheptanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroheptanoic acid (PFHpA)<\/a><\/td><td class=\"oth\">4.174<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">363<\/td><td class=\"oth\">319<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4- 13C4]heptanoic acid (13C4-PFHpA)<\/td><td class=\"oth\">4.174<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">367<\/td><td class=\"oth\">322<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\">Perfluoro-1-hexane[18O2]sulfonic acid (18O2-PFHxS)<\/td><td class=\"oth\">4.218<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">403<\/td><td class=\"oth\">84<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\">Sodium perfluoro-1-[1,2,3- 13C3]hexanesulfonate (13C3-PFHxS)<\/td><td class=\"oth\">4.218<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">402<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\">Perfluorohexane sulfonate (PFHxS)<\/td><td class=\"oth\">4.22<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">399<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for 4,8-Dioxa-3<i>H<\/i>-perfluorononanoic acid (ADONA)&#8221; title=&#8221;View compound information for 4,8-Dioxa-3<i>H<\/i>-perfluorononanoic acid (ADONA)&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/919005-14-4\/4,8-Dioxa-3<i>H-perfluorononanoic acid&#8221;&gt;4,8-Dioxa-3<i>H<\/i>-perfluorononanoic acid (ADONA)<\/a><\/td><td class=\"oth\">4.232<\/td><td class=\"oth\">10<\/td><td class=\"oth\">377<\/td><td class=\"oth\">251<\/td><td class=\"oth\">85<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\">2<i>H<\/i>,2<i>H<\/i>,3<i>H<\/i>,3<i>H<\/i>-Perfluorooctanoic acid (5:3FTCA)<\/td><td class=\"oth\">4.247<\/td><td class=\"oth\">62.5<\/td><td class=\"oth\">341<\/td><td class=\"oth\">237<\/td><td class=\"oth\">217<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\">1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluorooctane sulfonate (6:2 FTS)<\/td><td class=\"oth\">4.58<\/td><td class=\"oth\">10<\/td><td class=\"oth\">427<\/td><td class=\"oth\">407<\/td><td class=\"oth\">81<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\">Sodium 1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluoro-1-[1,2-13C2]-octane sulfonate (13C2-6:2FTS)<\/td><td class=\"oth\">4.581<\/td><td class=\"oth\">5<\/td><td class=\"oth\">429<\/td><td class=\"oth\">81<\/td><td class=\"oth\">409<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\">Perfluoro-n-[ 13C8]octanoic acid (13C8-PFOA)<\/td><td class=\"oth\">4.598<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">421<\/td><td class=\"oth\">376<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">4.601<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">413<\/td><td class=\"oth\">369<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\">Perfluoro-n-[ 13C4]octanoic acid (13C4-PFOA)<\/td><td class=\"oth\">4.601<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">417<\/td><td class=\"oth\">172<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\">Perfluoroheptane sulfonate (PFHpS)<\/td><td class=\"oth\">4.621<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">449<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononanoic acid (PFNA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-95-1\/Perfluorononanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononanoic acid (PFNA)<\/a><\/td><td class=\"oth\">4.944<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">463<\/td><td class=\"oth\">419<\/td><td class=\"oth\">219<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\">Perfluoro-n-[ 13C5]nonanoic acid (13C5-PFNA)<\/td><td class=\"oth\">4.944<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">468<\/td><td class=\"oth\">423<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\">Perfluoro-n-[ 13C9]nonanoic acid (13C9-PFNA)<\/td><td class=\"oth\">4.944<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">472<\/td><td class=\"oth\">427<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\">Perfluorooctane sulfonate (PFOS)<\/td><td class=\"oth\">4.949<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">499<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\">Sodium perfluoro-[ 13C4]octanesulfonate (13C4-PFOS)<\/td><td class=\"oth\">4.95<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">503<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\">Sodium perfluoro-[ 13C8]octanesulfonate (13C8-PFOS)<\/td><td class=\"oth\">4.95<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">507<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\">3-Perfluoroheptyl propanoic acid (7:3FTCA)<\/td><td class=\"oth\">5.046<\/td><td class=\"oth\">62.5<\/td><td class=\"oth\">441<\/td><td class=\"oth\">317<\/td><td class=\"oth\">337<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/756426-58-1\/9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid\" target=\"_blank\" rel=\"noopener\">9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS)<\/a><\/td><td class=\"oth\">5.114<\/td><td class=\"oth\">10<\/td><td class=\"oth\">531<\/td><td class=\"oth\">351<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">533<\/td><td class=\"oth\">353<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecanoic acid (PFDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-76-2\/Perfluorodecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecanoic acid (PFDA)<\/a><\/td><td class=\"oth\">5.237<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">513<\/td><td class=\"oth\">469<\/td><td class=\"oth\">219<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,5,6- 13C2]decanoic acid (13C2-PFDA)<\/td><td class=\"oth\">5.237<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">515<\/td><td class=\"oth\">470<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,5,6- 13C6]decanoic acid (13C6-PFDA)<\/td><td class=\"oth\">5.237<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">519<\/td><td class=\"oth\">474<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\">1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluorodecane sulfonate (8:2 FTS)<\/td><td class=\"oth\">5.238<\/td><td class=\"oth\">10<\/td><td class=\"oth\">527<\/td><td class=\"oth\">507<\/td><td class=\"oth\">81<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\">Sodium 1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluoro-1-[1,2- 13C2]-decane sulfonate (13C2-8:2FTS)<\/td><td class=\"oth\">5.238<\/td><td class=\"oth\">5<\/td><td class=\"oth\">529<\/td><td class=\"oth\">81<\/td><td class=\"oth\">509<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononanesulfonic acid (PFNS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68259-12-1\/Perfluorononanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononanesulfonic acid (PFNS)<\/a><\/td><td class=\"oth\">5.239<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">549<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\">N-methyl-d 3-perfluoro-1-octanesulfonamidoacetic acid (D3-NMeFOSAA)<\/td><td class=\"oth\">5.361<\/td><td class=\"oth\">5<\/td><td class=\"oth\">573<\/td><td class=\"oth\">419<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2355-31-9\/N-methyl perfluorooctanesulfonamidoacetic acid\" target=\"_blank\" rel=\"noopener\">N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)<\/a><\/td><td class=\"oth\">5.366<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">570<\/td><td class=\"oth\">419<\/td><td class=\"oth\">483<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecanesulfonic acid (PFDS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-77-3\/Perfluorodecanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecanesulfonic acid (PFDS)<\/a><\/td><td class=\"oth\">5.475<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">599<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroundecanoic acid (PFUnA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2058-94-8\/Perfluoroundecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroundecanoic acid (PFUnA)<\/a><\/td><td class=\"oth\">5.486<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">563<\/td><td class=\"oth\">519<\/td><td class=\"oth\">269<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,5,6,7- 13C7]undecanoic acid (13C7-PFUnA)<\/td><td class=\"oth\">5.486<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">570<\/td><td class=\"oth\">525<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\">N-ethyl-d 5-perfluoro-1-octanesulfonamidoacetic acid (D5-NEtFOSAA)<\/td><td class=\"oth\">5.487<\/td><td class=\"oth\">5<\/td><td class=\"oth\">589<\/td><td class=\"oth\">419<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2991-50-6\/N-ethyl perfluorooctanesulfonamidoacetic acid\" target=\"_blank\" rel=\"noopener\">N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)<\/a><\/td><td class=\"oth\">5.487<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">584<\/td><td class=\"oth\">419<\/td><td class=\"oth\">526<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/763051-92-9\/11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid\" target=\"_blank\" rel=\"noopener\">11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)<\/a><\/td><td class=\"oth\">5.59<\/td><td class=\"oth\">10<\/td><td class=\"oth\">631<\/td><td class=\"oth\">451<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">633<\/td><td class=\"oth\">453<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\">Perfluorooctanesulfonamide (PFOSA)<\/td><td class=\"oth\">5.669<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">498<\/td><td class=\"oth\">78<\/td><td class=\"oth\">478<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\">Perfluoro-1-[ 13C8]octanesulfonamide (13C8-PFOSA)<\/td><td class=\"oth\">5.669<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">506<\/td><td class=\"oth\">78<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorododecanoic acid (PFDoA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-55-1\/Perfluorododecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorododecanoic acid (PFDoA)<\/a><\/td><td class=\"oth\">5.691<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">613<\/td><td class=\"oth\">569<\/td><td class=\"oth\">319<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2- 13C2]dodecanoic acid (13C2-PFDoA)<\/td><td class=\"oth\">5.692<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">615<\/td><td class=\"oth\">570<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorododecanesulfonic acid (PFDoS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79780-39-5\/Perfluorododecanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorododecanesulfonic acid (PFDoS)<\/a><\/td><td class=\"oth\">5.861<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">699<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotridecanoic acid (PFTrDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72629-94-8\/Perfluorotridecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotridecanoic acid (PFTrDA)<\/a><\/td><td class=\"oth\">5.876<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">663<\/td><td class=\"oth\">619<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotetradecanoic acid (PFTeDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/376-06-7\/Perfluorotetradecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotetradecanoic acid (PFTeDA)<\/a><\/td><td class=\"oth\">6.031<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">713<\/td><td class=\"oth\">669<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2- 13C2]tetradecanoic acid (13C2-PFTeDA)<\/td><td class=\"oth\">6.031<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">715<\/td><td class=\"oth\">670<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\">N-methyl perfluorooctanesulfonamide (NMeFOSA)<\/td><td class=\"oth\">6.158<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">512<\/td><td class=\"oth\">219<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\">N-methyl-D 3-perfluoro-1-octanesulfonamide (D3-NMeFOSA)<\/td><td class=\"oth\">6.159<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">515<\/td><td class=\"oth\">219<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\">N-methyl perfluorooctanesulfonamidoethanol (NMeFOSE)<\/td><td class=\"oth\">6.166<\/td><td class=\"oth\">25<\/td><td class=\"oth\">616<\/td><td class=\"oth\">59<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\">N-methyl-D 7-perfluorooctanesulfonamidoethanol (D7-NMeFOSE)<\/td><td class=\"oth\">6.167<\/td><td class=\"oth\">25<\/td><td class=\"oth\">623<\/td><td class=\"oth\">59<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\">N-ethyl-D 5-perfluoro-1-octanesulfonamide (D5-NEtFOSA)<\/td><td class=\"oth\">6.295<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">531<\/td><td class=\"oth\">219<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\">N-ethyl perfluorooctanesulfonamide (NEtFOSA)<\/td><td class=\"oth\">6.296<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">526<\/td><td class=\"oth\">219<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\">N-ethyl perfluorooctanesulfonamidoethanol (NEtFOSE)<\/td><td class=\"oth\">6.298<\/td><td class=\"oth\">25<\/td><td class=\"oth\">630<\/td><td class=\"oth\">59<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\">N-ethyl-D 9-perfluorooctanesulfonamidoethanol (D9-NEtFOSE)<\/td><td class=\"oth\">6.298<\/td><td class=\"oth\">25<\/td><td class=\"oth\">639<\/td><td class=\"oth\">59<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Force C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9634252\" rel=\"noopener\">cat.# 9634252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>1.8 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>100 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>3 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 5 mM ammonium acetate  <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>6<\/td><td>0.4<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>6.6<\/td><td>0.4<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>6.61<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>7.5<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>~400 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ-S<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY Premier<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Resprep PFAS cartridges (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/28930\" rel=\"noopener\">cat.# 28930<\/a>) and a Thermo AutoTrace PFAS instrument were used for the following sample preparation procedure.<br \/>1. Spike 500 mL DI water with 200 \u00b5L of Wellington EPA-1633STK and 25 \u00b5L of Wellington MPFAC-HIF-ES.<br \/>2. Rinse cartridge with 15 mL of 1% ammonium hydroxide in methanol.<br \/>3. Rinse with 5 mL of 0.3 M formic acid in water.<br \/>4. Load sample onto SPE cartridge dropwise at 5 mL\/min.<br \/>5. Rinse bottle with 5 mL DI water, load onto SPE cartridge dropwise at 5 mL\/min, repeat.<br \/>6. Rinse bottle with 5 mL of 1:1 0.1 M formic acid:methanol and load onto SPE cartridge dropwise at 5 mL\/min.<br \/>7. Flow nitrogen through cartridge for 15 minutes.<br \/>8. Rinse bottles with 5 mL of 1% ammonium hydroxide in methanol, elute into collection vessel.<br \/>9. Add 25 \u00b5L of concentrated acetic acid and 25 \u00b5L of Wellington MPFAC-HIF-IS.<br \/>10. Transfer aliquot to autosampler vial (cat. # 23243) and cap (cat. # 23244).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>A PFAS delay column (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/27854\" rel=\"noopener\">cat.# 27854<\/a>) was installed before the injector.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9634252<\/li><li>27854<\/li><li>28930<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>pfas-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0599.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">\u8868 I\uff1a\u4f7f\u7528 Resprep PFAS\u5c0f\u67f1\u5236\u5907\u7684\u8bd5\u5242\u6c34\u6837\u54c1\uff0c\u6240\u6709 PFAS \u5747\u8fbe\u5230\u76ee\u6807\u56de\u6536\u7387\uff0870-135%\uff09<\/p>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><thead><tr><th><strong>\u5316\u5408\u7269<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u7f29\u5199<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>MDL (ng\/L)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u7a7a\u767d (ng\/L)*<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u56de\u6536\u7387<\/strong><br><strong>(%)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong><strong>\u7cbe\u5bc6\u5ea6<\/strong>(%RSD)<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Perfluorobutanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFBA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.34<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">112<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td>Perfluoro-3-methoxypropanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFMPA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">109<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td>3-Perfluoropropyl propanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">3:3FTCA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.31<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">95<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td>Perfluoropentanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFPeA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.26<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">111<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td>Perfluorobutane sulfonate<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFBS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.19<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">101<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td>Perfluoro-4-methoxybutanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFMBA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.18<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">111<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td>Perfluoro(2-ethoxyethane)sulfonic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFEESA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.15<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">94<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td>Nonafluoro-3,6-dioxaheptanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">NFDHA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.46<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">121<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td>1<em>H<\/em>, 1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluorohexane sulfonate<\/td><td class=\"has-text-align-center\" data-align=\"center\">4:2 FTS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.36<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">104<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td>2<em>H<\/em>,2<em>H<\/em>,3<em>H<\/em>,3<em>H<\/em>-Perfluorooctanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">5:3FTCA<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.48<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">102<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td>Perfluorohexanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFHxA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.08<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">113<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td>Perfluoropentane sulfonate<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFPeS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.07<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">122<\/td><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><\/tr><tr><td>Hexafluoropropylene oxide dimer acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">HFPO-DA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.40<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">114<\/td><td class=\"has-text-align-center\" data-align=\"center\">12<\/td><\/tr><tr><td>Perfluoroheptanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFHpA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.08<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">109<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td>Perfluorohexane sulfonate<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFHxS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.07<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">104<\/td><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><\/tr><tr><td>4,8-Dioxa-3<em>H<\/em>-perfluorononanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">ADONA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.39<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">99<\/td><td class=\"has-text-align-center\" data-align=\"center\">9<\/td><\/tr><tr><td>1<em>H,<\/em>1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluorooctane sulfonate<\/td><td class=\"has-text-align-center\" data-align=\"center\">6:2 FTS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.37<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">107<\/td><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><\/tr><tr><td>3-Perfluoroheptyl propanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">7:3FTCA<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.32<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">100<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td>Perfluoroheptane sulfonate<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFHpS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.76<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">121<\/td><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><\/tr><tr><td>Perfluorooctanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFOA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.32<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">104<\/td><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><\/tr><tr><td>Perfluorooctane sulfonate<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFOS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">112<\/td><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><\/tr><tr><td>Perfluorooctanesulfonamide<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFOSA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.21<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">81<\/td><td class=\"has-text-align-center\" data-align=\"center\">11<\/td><\/tr><tr><td>Perfluorononanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFNA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.08<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">114<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td><em>N<\/em>-methyl perfluorooctanesulfonamide<\/td><td class=\"has-text-align-center\" data-align=\"center\">NMeFOSA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.07<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">104<\/td><td class=\"has-text-align-center\" data-align=\"center\">13<\/td><\/tr><tr><td>9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">9Cl-PF3ONS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.61<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">85<\/td><td class=\"has-text-align-center\" data-align=\"center\">11<\/td><\/tr><tr><td>Perfluorononanesulfonic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFNS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.25<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">79<\/td><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><\/tr><tr><td>Perfluorodecanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.18<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">117<\/td><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><\/tr><tr><td><em>N<\/em>-ethyl perfluorooctanesulfonamide<\/td><td class=\"has-text-align-center\" data-align=\"center\">NEtFOSA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.14<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">112<\/td><td class=\"has-text-align-center\" data-align=\"center\">15<\/td><\/tr><tr><td>1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluorodecane sulfonate<\/td><td class=\"has-text-align-center\" data-align=\"center\">8:2 FTS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.91<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">113<\/td><td class=\"has-text-align-center\" data-align=\"center\">11<\/td><\/tr><tr><td>Perfluoroundecanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFUnA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.26<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">125<\/td><td class=\"has-text-align-center\" data-align=\"center\">12<\/td><\/tr><tr><td><em>N<\/em>-methyl perfluorooctanesulfonamidoacetic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">NMeFOSAA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.15<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">95<\/td><td class=\"has-text-align-center\" data-align=\"center\">12<\/td><\/tr><tr><td><em>N<\/em>-ethyl perfluorooctanesulfonamidoacetic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">NEtFOSAA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.23<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">93<\/td><td class=\"has-text-align-center\" data-align=\"center\">12<\/td><\/tr><tr><td>Perfluorodecanesulfonic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFDS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.25<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">94<\/td><td class=\"has-text-align-center\" data-align=\"center\">23<\/td><\/tr><tr><td>11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">11Cl-PF3OUdS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.56<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">77<\/td><td class=\"has-text-align-center\" data-align=\"center\">25<\/td><\/tr><tr><td>Perfluorododecanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFDoA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.27<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">118<\/td><td class=\"has-text-align-center\" data-align=\"center\">15<\/td><\/tr><tr><td><em>N<\/em>-methyl perfluorooctanesulfonamidoethanol<\/td><td class=\"has-text-align-center\" data-align=\"center\">NMeFOSE<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.11<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">106<\/td><td class=\"has-text-align-center\" data-align=\"center\">9<\/td><\/tr><tr><td><em>N<\/em>-ethyl perfluorooctanesulfonamidoethanol<\/td><td class=\"has-text-align-center\" data-align=\"center\">NEtFOSE<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">111<\/td><td class=\"has-text-align-center\" data-align=\"center\">9<\/td><\/tr><tr><td>Perfluorotridecanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFTrDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.33<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">108<\/td><td class=\"has-text-align-center\" data-align=\"center\">15<\/td><\/tr><tr><td>Perfluorododecanesulfonic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFDoS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.13<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">89<\/td><td class=\"has-text-align-center\" data-align=\"center\">12<\/td><\/tr><tr><td>Perfluorotetradecanoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">PFTeDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.32<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">102<\/td><td class=\"has-text-align-center\" data-align=\"center\">23<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">*ND = \u672a\u68c0\u51fa\uff08\u4f4e\u4e8e MDL\uff09\u3002<\/p>\n\n\n\n<h2 id=\"filteraid\" class=\"wp-block-heading\"><strong>\u51fa\u5382\u9884\u88c5\u52a9\u6ee4\u5242\u9009\u9879\u786e\u4fdd\u6837\u54c1\u524d\u5904\u7406\u66f4\u5feb\u901f\u3001\u66f4\u6709\u6548<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Resprep PFAS \u5c0f\u67f1\u8fd8\u63d0\u4f9b Restek \u72ec\u6709\u7684\u51fa\u5382\u9884\u88c5\u52a9\u6ee4\u5242\u7248\u672c\uff0c\u53ef\u9632\u6b62\u5835\u585e\uff0c\u5904\u7406\u6837\u54c1\u65f6\u6bd4\u624b\u52a8\u586b\u88c5\u73bb\u7483\u6bdb\u6d41\u52a8\u5f97\u66f4\u987a\u7545\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u6280\u672f\u4eba\u5458\u6309EPA 1633 \u7684\u8bf4\u660e\uff08\u7b2c 12.1.1 \u8282\uff09\u5c06\u73bb\u7483\u68c9\u586b\u88c5\u81f3\u67f1\u7ba1\u7ba1\u8eab\u4e00\u534a\u9ad8\u5ea6\u4ee5\u9002\u914d\u6240\u6709\u6837\u54c1\u57fa\u8d28\u65f6\uff0c\u73bb\u7483\u68c9\u7684\u7528\u91cf\u548c\u586b\u88c5\u5bc6\u5ea6\u53ef\u80fd\u5b58\u5728\u663e\u8457\u5dee\u5f02\uff0c\u8fd9\u610f\u5473\u7740\u6837\u54c1\u6d41\u901f\u548c\u5835\u585e\u60c5\u51b5\u4e5f\u4f1a\u968f\u4e4b\u53d7\u5230\u5f71\u54cd\u3002Resprep PFAS \u5c0f\u67f1\u6240\u7528\u7684\u52a9\u6ee4\u5242\u5747\u5300\u4e00\u81f4\uff0c\u53ef\u63d0\u4f9b\u6709\u6548\u4e14\u7a33\u5b9a\u7684\u8fc7\u6ee4\u4e0e\u9632\u62a4\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u4e00\u9879\u6bd4\u8f83\u7a00\u91ca\u540e\u7684 ASTM \u5e9f\u6c34\u57fa\u8d28\u5206\u522b\u901a\u8fc7 Resprep PFAS\u5e26\u52a9\u6ee4\u5242\u5c0f\u67f1\u3001\u624b\u52a8\u586b\u88c5\u73bb\u7483\u68c9\u7684 WAX \u5c0f\u67f1\u4ee5\u53ca\u5355\u7eaf WAX \u67f1\u7ba1\u7684\u6d41\u52a8\u6027\u5b9e\u9a8c\u4e2d\uff0c\u53ea\u6709\u51fa\u5382\u9884\u88c5\u52a9\u6ee4\u5242\u7684 Resprep PFAS \u5c0f\u67f1\u672a\u53d1\u751f\u5835\u585e\u5e76\u80fd\u8403\u53d6\u5168\u90e8\u6837\u54c1\u4f53\u79ef\uff08\u56fe 2\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868 II\uff1a\u6309EPA 1633 \u57fa\u4e8e\u9ad8\u5ea6\u7684\u8bf4\u660e\u624b\u52a8\u586b\u88c5\u67f1\u7ba1\u65f6\uff0c\u73bb\u7483\u68c9\u7528\u91cf\u548c\u586b\u88c5\u5bc6\u5ea6\u5728\u4e0d\u540c\u6280\u672f\u4eba\u5458\u4e4b\u95f4\u53ef\u80fd\u5b58\u5728\u663e\u8457\u5dee\u5f02<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong><strong>\u6280\u672f\u4eba\u5458<\/strong> 1<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong><strong>\u6280\u672f\u4eba\u5458<\/strong> 2<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong><strong>\u6280\u672f\u4eba\u5458<\/strong> 3<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong><strong>\u6280\u672f\u4eba\u5458<\/strong> 4<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong>\u5e73\u5747\u73bb\u7483\u68c9\u8d28\u91cf mg\uff08n = 3\uff09<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">39<\/td><td class=\"has-text-align-center\" data-align=\"center\">150<\/td><td class=\"has-text-align-center\" data-align=\"center\">51<\/td><td class=\"has-text-align-center\" data-align=\"center\">116<\/td><\/tr><tr><td><strong>\u6807\u51c6\u504f\u5dee (SD)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td class=\"has-text-align-center\" data-align=\"center\">13<\/td><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><td class=\"has-text-align-center\" data-align=\"center\">49<\/td><\/tr><tr><td><strong>\u76f8\u5bf9\u6807\u51c6\u504f\u5dee (%RSD)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">5%<\/td><td class=\"has-text-align-center\" data-align=\"center\">8%<\/td><td class=\"has-text-align-center\" data-align=\"center\">14%<\/td><td class=\"has-text-align-center\" data-align=\"center\">42%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 2\uff1a\u53ea\u6709\u51fa\u5382\u9884\u88c5\u52a9\u6ee4\u5242\u7684 Resprep PFAS \u5c0f\u67f1\u6210\u529f\u8403\u53d6\u4e86\u5168\u90e8 500 mL \u7ecf 2.5 \u500d\u7a00\u91ca\u7684 ASTM \u5e9f\u6c34\u57fa\u8d28\uff08\u603b\u60ac\u6d6e\u56fa\u4f53 = 100 mg\/L\uff09<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"487\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-02-1024x487.jpg\" alt=\"\" class=\"wp-image-24058\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-02-1024x487.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-02-300x143.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-02-768x365.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evss4368-02.jpg 1144w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u7efc\u4e0a\u6240\u8ff0\uff0c\u91c7\u7528\u5e26\u51fa\u5382\u9884\u88c5\u52a9\u6ee4\u5242\u7684 Resprep PFAS\u5c0f\u67f1\uff0c\u53ef\u663e\u8457\u7b80\u5316\u6837\u54c1\u524d\u5904\u7406\u6d41\u7a0b\uff0c\u8282\u7701\u64cd\u4f5c\u65f6\u95f4\u3001\u964d\u4f4e\u53d8\u5f02\u6027\u5e76\u786e\u4fdd\u5206\u6790\u6027\u80fd\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">                                \u8d27\u53f7\uff1a 9634252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force C18, 1.8 \u00b5m, 50 x 2.1 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28931\">                                \u8d27\u53f7\uff1a 28931                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep PFAS SPE Cartridge with Filter Aid, 6 mL, Filter Aid 2000 mg\/WAX 150 mg\/GCB 50 mg, 30-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28931\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28930\">                                \u8d27\u53f7\uff1a 28930                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep PFAS SPE Cartridge, 6 mL, WAX 150 mg\/GCB 50 mg, 30-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28930\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u8d27\u53f7\uff1a 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS Delay Column, 5 \u00b5m, 50 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28298-VM\">                                \u8d27\u53f7\uff1a 28298-VM                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep QR-12 Vacuum Manifold<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28298-VM\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28310-VM\">                                \u8d27\u53f7\uff1a 28310-VM                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Quick Replace Liners, PTFE, for Resprep QR Vacuum Manifolds, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28310-VM\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26250\">                                \u8d27\u53f7\uff1a 26250                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep Sample Delivery System, 6-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26250\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_3b9a6b-09{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_3b9a6b-09 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id99903_b5fa4b-ad{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id99903_b5fa4b-ad alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column99903_2824bd-5d > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_2824bd-5d{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_2824bd-5d\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading99903_df06fd-cb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading99903_df06fd-cb\"><span class=\"kb-adv-text-inner\">\u60a8\u7684PFAS\u5206\u6790\u9700\u8981\u5e2e\u52a9\u5417\uff1f<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">\u4ece\u65b9\u6cd5\u9009\u62e9\u5230\u4ea7\u54c1\u63a8\u8350\uff0cRestek PFAS \u4e13\u5bb6\u52a9\u60a8\u5e94\u5bf9\u590d\u6742\u5206\u6790\u6d41\u7a0b\uff0c\u83b7\u5f97\u51c6\u786e\u3001\u53ef\u9760\u7684\u5206\u6790\u7ed3\u679c\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns99903_bac608-3f{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns99903_bac608-3f .kt-button{font-weight:normal;font-style:normal;}.kt-btns99903_bac608-3f .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns99903_bac608-3f\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn99903_980c0c-c6.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn99903_980c0c-c6.kb-button:hover .kb-svg-icon-wrap, .kb-btn99903_980c0c-c6.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn99903_980c0c-c6 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/explore.restek.com\/PFAS\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Contact a PFAS<\/strong> <strong>expert<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4f7f\u7528\u53cc\u5c42 Resprep PFAS \u5c0f\u67f1\u7cbe\u7b80 PFAS \u6837\u54c1\u524d\u5904\u7406 \u5bf9\u4e8e\u975e\u996e\u7528\u6c34\u3001\u56fa\u4f53\u3001\u751f\u7269\u56fa\u4f53\u548c\u7ec4\u7ec7\u7b49\u590d\u6742\u6837\u54c1\u57fa\u8d28\u4e2d\u7684\u75d5\u91cf\u5168\u6c1f\u53ca\u591a\u6c1f\u70f7\u57fa\u7269\u8d28\uff08Per- and Polyfluoroalkyl Substances, PFAS\uff09\u5206\u6790\uff0c\u6709\u6548\u7684\u6837\u54c1\u524d\u5904\u7406\u81f3\u5173\u91cd\u8981\u3002 \u901a\u5e38\u91c7\u7528\u56fa\u76f8\u8403\u53d6\uff08Solid Phase Extraction, SPE\uff09\uff0c\u4f46\u5982\u679c\u5b58\u5728\u80cc\u666f PFAS\uff0c\u6216\u6837\u54c1\u6210\u5206\u5835\u585e SPE \u67f1\u7ba1\uff0c\u5219\u96be\u4ee5\u83b7\u5f97\u826f\u597d\u7ed3\u679c\u3002 EPA 1633\u65b9\u6cd5\u5148\u91c7\u7528\u586b\u6709\u73bb\u7483\u6bdb\u7684WAX\u5c0f\u67f1\u8fdb\u884c\u57fa\u8d28\u63d0\u53d6\uff0c\u968f\u540e\u901a\u8fc7GCB\u5c0f\u67f1\u8fdb\u884c\u51c0\u5316\u3002\u8bb8\u591a\u5b9e\u9a8c\u5ba4\u6b63\u91c7\u7528\u78b3\u8403\u53d6\u67f1\u66ff\u4ee3 dGCB\u3002 \u5c3d\u7ba1\u8be5\u65b9\u6cd5\u53ef\u884c\uff0c\u4f46\u9700\u8981\u4e24\u652fSPE\u5c0f\u67f1\u4e14\u9700\u624b\u52a8\u586b\u88c5\u73bb\u7483\u6bdb\uff0c\u4e24\u6b65\u64cd\u4f5c\u4e0d\u4ec5\u589e\u52a0\u4e86\u989d\u5916\u7684\u65f6\u95f4\u548c\u64cd\u4f5c\u590d\u6742\u6027\uff0c\u8fd8\u589e\u52a0\u4e86\u6837\u54c1\u91c7\u96c6\u548c\u524d\u5904\u7406\u8fc7\u7a0b\u4e2d\u542bPFAS\u6750\u6599\u5f15\u8d77\u4ea4\u53c9\u6c61\u67d3\u7684\u98ce\u9669\u3002 \u4f7f\u7528\u5e26\u52a9\u6ee4\u5242\u7684 Resprep PFAS \u5c0f\u67f1\uff0c\u7b80\u5316\u60a8\u7684\u6837\u54c1\u524d\u5904\u7406\u6d41\u7a0b Resprep PFAS \u53cc\u5c42\u5c0f\u67f1\u662f\u66f4\u7b80\u5355\u7684\u89e3\u51b3\u65b9\u6848 \u91c7\u7528\u53cc\u5c42\u586b\u6599\u7684Resprep PFAS\u8403\u53d6\u5c0f\u67f1\uff0c\u53ef\u663e\u8457\u7b80\u5316PFAS\u6837\u54c1\u524d\u5904\u7406\u6d41\u7a0b\u3002\u8be5\u8403\u53d6\u67f1\u5c06WAX\u8403\u53d6\u548cGCB\u51c0\u5316\u5408\u4e8c\u4e3a\u4e00\uff0c\u6709\u52a9\u4e8e\u964d\u4f4e\u6c61\u67d3\u98ce\u9669\u3002\u5728\u6b64\u5feb\u901f\u7b80\u4fbf\u7684\u5de5\u4f5c\u6d41\u7a0b\u4e2d\uff0c\u5c0f\u67f1\u5185\u88c5\u586b\u7684\u8d85\u6d01\u51c0\u7684WAX\u5438\u9644\u5242\u548cGCB\u5438\u9644\u5242\uff0c\u53ef\u786e\u4fdd\u6ee1\u8db3\u996e\u7528\u6c34\u53ca\u5176\u4ed6\u6837\u54c1\u4e2dPFAS\u5206\u6790\u7684\u65b9\u6cd5\u6027\u80fd\u8981\u6c42\u3002 \u6b64\u5916\uff0c\u53ef\u9009\u914d\u7684\u5de5\u5382\u9884\u88c5\u52a9\u6ee4\u5242\uff0c\u7701\u53bb\u4e86\u6c34\u6837\u5904\u7406\u8fc7\u7a0b\u4e2d\u624b\u52a8\u586b\u88c5\u73bb\u7483\u6bdb\u7684\u6b65\u9aa4\uff0c\u4ece\u800c\u8282\u7701\u4e86\u65f6\u95f4\u5e76\u6d88\u9664\u4e86\u64cd\u4f5c\u5dee\u5f02\u6027\u3002\u8fd9\u79cd\u5373\u7528\u578b\u89e3\u51b3\u65b9\u6848\u53ef\u6709\u6548\u9632\u6b62\u5835\u585e\uff0c\u5373\u4f7f\u9762\u5bf9\u57fa\u8d28\u8f83\u810f\u7684\u6837\u54c1\uff0c\u4e5f\u53ef\u901a\u8fc7\u5355\u6b21\u8403\u53d6\u5feb\u901f\u5b8c\u6210\u5904\u7406\u3002 \u5feb\u901f\u4e14\u4e00\u81f4\u5730\u6ee1\u8db3\u6027\u80fd\u8981\u6c42 Resprep PFAS\u53cc\u5c42\u5c0f\u67f1\u4e13\u4e3a\u5e2e\u52a9\u5b9e\u9a8c\u5ba4\u6ee1\u8db3 PFAS \u6027\u80fd\u8981\u6c42\u800c\u5f00\u53d1\uff0c\u5185\u542b\u8d85\u7eaf\u51c0\u3001\u9ad8\u54c1\u8d28\u7684 WAX \u548cGCB\u586b\u6599\uff0c\u53ef\u5b9e\u73b0\u6709\u6548\u7684\u8403\u53d6\u4e0e\u51c0\u5316\u3002\u6bcf\u4e00\u6279 WAX \u5438\u9644\u5242\u5747\u68c0\u6d4b\u4e86EPA 1633\u65b9\u6cd5\u4e2d\u5f85\u6d4bPFAS\u7684\u7a7a\u767d\u503c\uff0c\u4ee5\u8bc1\u660e\u5176\u6d01\u51c0\u5ea6\u5e76\u786e\u4fdd\u4e0d\u5f15\u5165\u80cc\u666f PFAS\u3002\u6b64\u5916\uff0c\u9ad8\u6027\u80fd\u7684 GCB\u5438\u9644\u5242\u8f83\u5176\u4ed6\u78b3\u6750\u6599\u80fd\u63d0\u4f9b\u66f4\u6709\u6548\u3001\u66f4\u4e00\u81f4\u7684\u51c0\u5316\u3002\u4e24\u79cd\u586b\u6599\u96c6\u6210\u4e8e\u5355\u652fSPE\u5c0f\u67f1\uff0c\u4f7f\u6837\u54c1\u524d\u5904\u7406\u66f4\u4e3a\u5feb\u901f\uff0c\u5e76\u83b7\u5f97\u6d01\u51c0\u7684\u8403\u53d6\u6db2\u548c\u4f18\u5f02\u7684\u5206\u6790\u6027\u80fd\u3002 \u4e24\u79cd\u5438\u9644\u5242\u5408\u5e76\u5728\u540c\u4e00\u8403\u53d6\u67f1\u4e2d\uff0c\u53ef\u4f7f PFAS \u6837\u54c1\u5236\u5907\u901f\u5ea6\u5927\u5927\u52a0\u5feb\u3002\u5f53\u4e0e LC-MS \u6216\u9ad8\u5206\u8fa8\u8d28\u8c31\u8054\u7528\u8fdb\u884c\u6570\u636e\u5206\u6790\u65f6\uff0c\u53ef\u5feb\u901f\u83b7\u5f97\u6d01\u51c0\u7684\u63d0\u53d6\u7269\u548c\u51fa\u8272\u7684\u5206\u6790\u7ed3\u679c\uff08\u56fe 1 \u548c\u8868 I\uff09\u3002 \u56fe 1\uff1aResprep PFAS&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[2165,2161],"post-badge":[],"resource-type":[],"product-library":[2391,2402,2375,2373],"resource-technique":[2304],"ppma_author":[5],"class_list":["post-102811","post","type-post","status-publish","format-standard","hentry","category-articles","industries-application-pfas-testing","industries-application-environmental","product-library-lc-columns","product-library-spe-sle","product-library-sample-preparation-products","product-library-liquid-chromatography-products","resource-technique-solid-phase-extraction-spe"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"industries-application":[{"value":2165,"label":"PFAS Testing"},{"value":2161,"label":"Environmental"}],"product-library":[{"value":2391,"label":"LC Columns"},{"value":2402,"label":"SPE &amp; SLE"},{"value":2375,"label":"Sample Preparation Products"},{"value":2373,"label":"Liquid Chromatography Products"}],"resource-technique":[{"value":2304,"label":"Solid-Phase Extraction (SPE)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":7,"category_count":511,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":5,"user_id":2,"is_guest":0,"slug":"patrick-gallagherrestek-com","display_name":"Patrick Gallagher","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Gallagher_Patrick_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Gallagher_Patrick_Profile.jpg"},"author_category":"1","first_name":"Patrick","last_name":"Gallagher","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/102811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=102811"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/102811\/revisions"}],"predecessor-version":[{"id":102879,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/102811\/revisions\/102879"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=102811"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=102811"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=102811"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=102811"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=102811"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=102811"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=102811"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=102811"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=102811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}