{"id":102834,"date":"2023-12-11T00:00:00","date_gmt":"2023-12-11T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=102834"},"modified":"2026-10-05T15:22:50","modified_gmt":"2026-10-05T15:22:50","slug":"accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles-ja\/accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns\/","title":{"rendered":"\u4f7f\u7528 Restek \u5168\u65b0\u60f0\u6027\u6db2\u76f8\u67f1\u4e0e\u4fdd\u62a4\u67f1\u7cbe\u786e\u5206\u6790\u91d1\u5c5e\u654f\u611f\u5316\u5408\u7269"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Restek \u5168\u65b0\u7684\u60f0\u6027\u6db2\u76f8\u67f1\u6280\u672f\u53ef\u5e2e\u52a9\u5b9e\u9a8c\u5ba4\u6539\u5584\u91d1\u5c5e\u654f\u611f\u5316\u5408\u7269\u7684\u5206\u6790\u3002\u8be5\u6db2\u76f8\u8272\u8c31\u67f1\u4e0d\u9508\u94a2\u8868\u5c42\u8986\u6709\u9ad8\u6027\u80fd\u60f0\u6027\u6d82\u5c42\uff0c\u80fd\u591f\u51cf\u5c11\u87af\u5408\u578b\u5206\u6790\u7269\u7684\u975e\u7279\u5f02\u6027\u5438\u9644\uff0c\u5b9e\u73b0\u9ad8\u7075\u654f\u68c0\u6d4b\u4e0e\u6d41\u7545\u7684\u8272\u8c31\u5cf0\u79ef\u5206\u3002\u642d\u914dRestek\u9ad8\u9009\u62e9\u6027\u56fa\u5b9a\u76f8\uff0c\u65b0\u578b\u60f0\u6027 <a href=\"https:\/\/www.restek.com\/c\/1119\" target=\"_blank\" rel=\"noopener\">\u6db2\u76f8\u8272\u8c31\u67f1<\/a> \u53ef\u5b8c\u7f8e\u9002\u7528\u4e8e\u6709\u673a\u78f7\u519c\u836f\u3001\u9709\u83cc\u6bd2\u7d20\u7b49\u91d1\u5c5e\u654f\u611f\u5316\u5408\u7269\u7684\u5206\u6790\u68c0\u6d4b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Restek \u60f0\u6027\u6db2\u76f8\u67f1\u56db\u5927\u5173\u952e\u4f18\u52bf\uff1a<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u6539\u5584\u5cf0\u5f62<\/strong>\u2014\u2014\u65e0\u9700\u949d\u5316\u5904\u7406\u6216\u6d41\u52a8\u76f8\u6dfb\u52a0\u5242<\/li>\n\n\n\n<li><strong>\u63d0\u5347\u54cd\u5e94\u4e0e\u5206\u6790\u7269\u56de\u6536\u7387<\/strong>\u2014\u2014\u53ef\u5b9e\u73b0\u66f4\u4f4e\u7684\u68c0\u6d4b\u9650<\/li>\n\n\n\n<li><strong>\u9ad8\u51c6\u786e\u5ea6\u4e0e\u9ad8\u901a\u91cf<\/strong>\u2014\u2014\u53d8\u5f02\u6027\u66f4\u5c0f<\/li>\n\n\n\n<li><strong>\u66f4\u7701\u65f6\u7684\u67f1\u5e73\u8861<\/strong>\u2014\u2014\u65e0\u9700\u590d\u6742\u7684\u949d\u5316\u5904\u7406<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u5353\u8d8a\u7684\u60f0\u6027\u5e26\u6765\u5353\u8d8a\u7684\u6027\u80fd<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6db2\u76f8\u8272\u8c31\u67f1\u5185\uff0c\u90e8\u5206\u5316\u5408\u7269\u6613\u4e0e\u91d1\u5c5e\u8868\u9762\u53d1\u751f\u975e\u7279\u5f02\u6027\u5438\u9644\uff08NSA\uff09\u6216\u975e\u7279\u5f02\u6027\u7ed3\u5408\uff08NSB\uff09\uff0c\u5bf9\u8be5\u7c7b\u5316\u5408\u7269\u7684\u5206\u6790\u957f\u671f\u4ee5\u6765\u5b58\u5728\u6280\u672f\u96be\u70b9\u3002\u6781\u6027\u5316\u5408\u7269\uff08\u591a\u4e3a\u9178\u6027\u7269\u8d28\uff09\u4f1a\u4e0e\u8272\u8c31\u67f1\u91d1\u5c5e\u5185\u58c1\u53d1\u751f\u76f8\u4e92\u4f5c\u7528\uff0c\u76f4\u89c2\u8868\u73b0\u4e3a\u5cf0\u5f62\u7578\u53d8\u3001\u68c0\u6d4b\u7075\u654f\u5ea6\u4e0b\u964d\uff0c\u6700\u7ec8\u5bfc\u81f4\u68c0\u6d4b\u6570\u636e\u53ef\u9760\u6027\u4e0d\u8db3\u3002\u672c\u54c1\u724c\u9ad8\u6027\u80fd\u60f0\u6027\u8272\u8c31\u67f1\u6280\u672f\u53ef\u6709\u6548\u6d88\u9664\u6d3b\u6027\u5206\u6790\u7269\u4e0e\u8272\u8c31\u67f1\u91d1\u5c5e\u786c\u4ef6\u4e4b\u95f4\u7684\u975e\u7279\u5f02\u6027\u5438\u9644\u4e0e\u975e\u7279\u5f02\u6027\u7ed3\u5408\uff0c\u4fdd\u969c\u5206\u6790\u4eba\u5458\u68c0\u6d4b\u91d1\u5c5e\u654f\u611f\u7c7b\u5206\u6790\u7269\u65f6\u6240\u5f97\u6570\u636e\u5177\u5907\u66f4\u9ad8\u53ef\u4fe1\u5ea6\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u5c06\u60f0\u6027\u6db2\u76f8\u67f1\u4e0e\u60f0\u6027\u4fdd\u62a4\u67f1\u914d\u5408\u4f7f\u7528\uff0c\u6536\u83b7\u66f4\u591a\u4f18\u52bf<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u60f0\u6027\u4fdd\u62a4\u67f1\u63d0\u4f9b\u591a\u79cd\u56fa\u5b9a\u76f8\uff0c\u5728\u4e3a \u6db2\u76f8\u67f1\u63d0\u4f9b\u6700\u4f73\u4fdd\u62a4\u7684\u540c\u65f6\uff0c\u4e5f\u53ef\u51cf\u5c11\u87af\u5408\u6027\u5206\u6790\u7269\u7684\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3002\u72ec\u7acb\u5f0f\u4fdd\u62a4\u67f1\u53ef\u4e0eRestek\u6240\u6709\u7cfb\u5217\u6db2\u76f8\u67f1\u914d\u5408\u4f7f\u7528\uff0c\u5e76\u4e13\u95e8\u8bbe\u8ba1\u7528\u4e8e\u8865\u5145\u548c\u589e\u5f3a\u60f0\u6027\u67f1\u7684\u6027\u80fd\u3002Restek\u60f0\u6027\u4fdd\u62a4\u67f1\u63d0\u4f9b\u591a\u79cd\u56fa\u5b9a\u76f8\uff0c\u5728\u4e3a \u6db2\u76f8\u67f1\u63d0\u4f9b\u6700\u4f73\u4fdd\u62a4\u7684\u540c\u65f6\uff0c\u4e5f\u53ef\u51cf\u5c11\u87af\u5408\u6027\u5206\u6790\u7269\u7684\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3002\u72ec\u7acb\u5f0f\u4fdd\u62a4\u67f1\u53ef\u4e0eRestek\u6240\u6709\u7cfb\u5217\u6db2\u76f8\u67f1\u914d\u5408\u4f7f\u7528\uff0c\u5e76\u4e13\u95e8\u8bbe\u8ba1\u7528\u4e8e\u8865\u5145\u548c\u589e\u5f3a\u60f0\u6027\u67f1\u7684\u6027\u80fd\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u4ea7\u54c1\u7ebf\u4e30\u5bcc\uff0c\u6ee1\u8db3\u60a8\u7684\u72ec\u7279\u9700\u6c42<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u60f0\u6027\u6db2\u76f8\u67f1\u63d0\u4f9b\u591a\u79cd\u7c7b\u578b\uff0c\u4ee5\u9002\u5e94\u5e7f\u6cdb\u7684\u5e94\u7528\u4e0e\u68c0\u6d4b\u65b9\u6cd5\u3002Restek\u60f0\u6027\u67f1\u53ef\u63d0\u4f9b\u4ee5\u4e0b\u7c7b\u578b\uff1aRaptor Biphenyl\u3001Raptor C18\u3001Raptor ARC-18\u3001Force Biphenyl \u548c Force C18\u3002\u9488\u5bf9\u4ee5\u4e0b\u7279\u5b9a\u5e94\u7528\uff0c\u63a8\u8350\u4f7f\u7528\u76f8\u5e94\u8272\u8c31\u67f1\uff1a<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u60f0\u6027 LC \u8272\u8c31\u67f1<\/strong><\/td><td><strong>\u5e94\u7528<\/strong><\/td><\/tr><tr><td>Raptor Inert ARC-18<\/td><td>\u519c\u836f<\/td><\/tr><tr><td>Raptor Inert Biphenyl<\/td><td>\u9709\u83cc\u6bd2\u7d20<\/td><\/tr><tr><td>Force Inert C18<\/td><td>\u7532\u57fa\u4e19\u4e8c\u9178<\/td><\/tr><tr><td>Raptor Inert C18<\/td><td>\u517d\u836f<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u519c\u836f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u519c\u836f\u591a\u7ec4\u5206\u7b5b\u67e5\u4f53\u7cfb\u7ec4\u5206\u79cd\u7c7b\u7e41\u591a\uff0c\u91c7\u7528\u60f0\u6027\u6db2\u76f8\u8272\u8c31\u67f1\u53ef\u663e\u8457\u63d0\u5347\u68c0\u6d4b\u6548\u679c\u3002\u78f7\u9178\u5316\u7c7b\u3001\u9178\u6027\u3001\u5f3a\u6781\u6027\u5316\u5408\u7269\u53ca\u53ef\u87af\u5408\u91d1\u5c5e\u7684\u7269\u8d28\uff08\u6709\u673a\u78f7\u519c\u836f\u7b49\uff09\u6613\u4e0e\u5206\u6790\u8272\u8c31\u67f1\u5185\u58c1\u91d1\u5c5e\u6d3b\u6027\u4f4d\u70b9\u53d1\u751f\u76f8\u4e92\u4f5c\u7528\u3002\u672c\u7814\u7a76\u5f00\u53d1\u7684\u65b0\u578b\u60f0\u6027\u6db2\u76f8\u8272\u8c31\u67f1\u53ef\u6709\u6548\u6d88\u9664\u8be5\u7c7b\u5438\u9644\u5e72\u6270\uff0c\u5168\u65b9\u4f4d\u63d0\u5347\u591a\u7ec4\u5206\u519c\u836f\u7684\u6574\u4f53\u5206\u6790\u6548\u80fd\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 1\uff1a\u5168\u65b0\u7684 Raptor Inert ARC-18 \u8272\u8c31\u67f1\u65e0\u9700\u4efb\u4f55\u67f1\u9884\u5904\u7406\u5373\u53ef\u63d0\u4f9b\u66f4\u9ad8\u7684\u7075\u654f\u5ea6\u3001\u56de\u6536\u7387\u548c\u66f4\u4f4e\u7684\u68c0\u6d4b\u9650<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0596.png\" alt=\"Pesticides on Raptor Inert ARC-18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0596<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><th style=\"text-align: center;width: 75px\">Peak Area<\/th><th style=\"text-align: center;width: 75px\">Peak Height<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methamidophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10265-92-6\/Methamidophos\" target=\"_blank\" rel=\"noopener\">Methamidophos<\/a><\/td><td class=\"oth\">1.33<\/td><td class=\"oth\">142.0<\/td><td class=\"oth\">94.0<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">428941<\/td><td class=\"oth\">105189<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acephate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/30560-19-1\/Acephate\" target=\"_blank\" rel=\"noopener\">Acephate<\/a><\/td><td class=\"oth\">1.55<\/td><td class=\"oth\">184.0<\/td><td class=\"oth\">143.0<\/td><td class=\"oth\">48.9<\/td><td class=\"oth\">300642<\/td><td class=\"oth\">104729<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Omethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1113-02-6\/Omethoate\" target=\"_blank\" rel=\"noopener\">Omethoate<\/a><\/td><td class=\"oth\">1.72<\/td><td class=\"oth\">214.0<\/td><td class=\"oth\">125.0<\/td><td class=\"oth\">182.9<\/td><td class=\"oth\">892008<\/td><td class=\"oth\">337690<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Monocrotophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6923-22-4\/Monocrotophos\" target=\"_blank\" rel=\"noopener\">Monocrotophos<\/a><\/td><td class=\"oth\">2.21<\/td><td class=\"oth\">224.1<\/td><td class=\"oth\">127.0<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">215810<\/td><td class=\"oth\">78425<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dicrotophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/141-66-2\/Dicrotophos\" target=\"_blank\" rel=\"noopener\">Dicrotophos<\/a><\/td><td class=\"oth\">2.35<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">112.1<\/td><td class=\"oth\">72.0<\/td><td class=\"oth\">404916<\/td><td class=\"oth\">159292<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-51-5\/Dimethoate\" target=\"_blank\" rel=\"noopener\">Dimethoate<\/a><\/td><td class=\"oth\">2.52<\/td><td class=\"oth\">230.0<\/td><td class=\"oth\">125.0<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">807805<\/td><td class=\"oth\">342939<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trichlorfon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52-68-6\/Trichlorfon\" target=\"_blank\" rel=\"noopener\">Trichlorfon<\/a><\/td><td class=\"oth\">2.53<\/td><td class=\"oth\">257.0<\/td><td class=\"oth\">108.9<\/td><td class=\"oth\">220.8<\/td><td class=\"oth\">173942<\/td><td class=\"oth\">63266<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Vamidothion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2275-23-2\/Vamidothion\" target=\"_blank\" rel=\"noopener\">Vamidothion<\/a><\/td><td class=\"oth\">2.54<\/td><td class=\"oth\">288.0<\/td><td class=\"oth\">146.0<\/td><td class=\"oth\">118.0<\/td><td class=\"oth\">1333829<\/td><td class=\"oth\">547308<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\">Mevinphos isomer 1<\/td><td class=\"oth\">2.55<\/td><td class=\"oth\">241.9<\/td><td class=\"oth\">126.9<\/td><td class=\"oth\">192.9<\/td><td class=\"oth\">311274<\/td><td class=\"oth\">129961<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\">Mevinphos isomer 2<\/td><td class=\"oth\">2.76<\/td><td class=\"oth\">241.9<\/td><td class=\"oth\">126.9<\/td><td class=\"oth\">192.9<\/td><td class=\"oth\">74030<\/td><td class=\"oth\">29802<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbaryl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/63-25-2\/Carbaryl\" target=\"_blank\" rel=\"noopener\">Carbaryl<\/a><\/td><td class=\"oth\">3.18<\/td><td class=\"oth\">202.1<\/td><td class=\"oth\">145.0<\/td><td class=\"oth\">127.0<\/td><td class=\"oth\">39671<\/td><td class=\"oth\">11924<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isocarbophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/24353-61-5\/Isocarbophos\" target=\"_blank\" rel=\"noopener\">Isocarbophos<\/a><\/td><td class=\"oth\">3.52<\/td><td class=\"oth\">291.1<\/td><td class=\"oth\">231.1<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">33294<\/td><td class=\"oth\">11941<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">Dimethomorph isomer 1<\/td><td class=\"oth\">3.96<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">300.9<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">511766<\/td><td class=\"oth\">172977<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\">Dimethomorph isomer 2<\/td><td class=\"oth\">4.13<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">300.9<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">877031<\/td><td class=\"oth\">328826<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Temephos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3383-96-8\/Temephos\" target=\"_blank\" rel=\"noopener\">Temephos<\/a><\/td><td class=\"oth\">5.70<\/td><td class=\"oth\">467.1<\/td><td class=\"oth\">124.9<\/td><td class=\"oth\">418.9<\/td><td class=\"oth\">164310<\/td><td class=\"oth\">64751<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Inert ARC-18   (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A12-T\" rel=\"noopener\">cat.# 9314A12-T<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>50 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>LC multiresidue pesticide standard #1 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31972\" rel=\"noopener\">cat.# 31972<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water, 0.1% formic acid<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 2 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 2 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>2.00<\/td><td>0.4<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>4.00<\/td><td>0.4<\/td><td>25<\/td><td>75<\/td><\/tr><tr><td>6.00<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>7.50<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>7.51<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>9.00<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu LCMS-8060<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31972<\/li><li>9314A12-T<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0596.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 2\uff1a\u4e0e\u4f20\u7edf\u4e0d\u9508\u94a2\u8272\u8c31\u67f1\u76f8\u6bd4\uff0c\u5168\u65b0\u7684 Raptor Inert ARC-18 \u8272\u8c31\u67f1\u53ef\u63d0\u4f9b\u5353\u8d8a\u7684\u5206\u6790\u7269\u56de\u6536\u7387<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0591.png\" alt=\"Comparison of Pesticides on Raptor Inert ARC-18 and Raptor ARC-18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0591<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31972<\/li><li>9314A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0591.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 3\uff1a\u519c\u836f\u5206\u6790\u7684\u5cf0\u9762\u79ef\u548c\u5cf0\u9ad8\u5747\u5927\u5e45\u63d0\u5347<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0593.png\" alt=\"Comparison of Pesticides on Raptor Inert ARC-18 and Raptor ARC-18 - Overlay View\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0593<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31972<\/li><li>9314A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0593.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8868 I\uff1a\u5728\u672c\u6b21\u519c\u836f\u5206\u6790\u4e2d\uff0cRestek \u5168\u65b0\u60f0\u6027\u67f1\u7684\u5cf0\u9762\u79ef\u548c\u5cf0\u9ad8\u8f83\u4e0d\u9508\u94a2\u67f1\u6700\u591a\u63d0\u5347 2 \u500d<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>\u5316\u5408\u7269<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\"><strong>\u5cf0\u9762\u79ef<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\"><strong>\u5cf0\u9ad8<\/strong><\/td><\/tr><tr><td><strong>\u4e0d\u9508\u94a2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>\u60f0\u6027<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>\u9762\u79ef\u6bd4(\u60f0\u6027\/\u4e0d\u9508\u94a2)<\/strong><\/td><td><strong>\u4e0d\u9508\u94a2<\/strong><\/td><td><strong>\u60f0\u6027<\/strong><\/td><td><strong>\u5cf0\u9ad8\u6bd4(\u60f0\u6027\/\u4e0d\u9508\u94a2)<\/strong><\/td><\/tr><tr><td>Methamidophos<\/td><td class=\"has-text-align-center\" data-align=\"center\">254969<\/td><td class=\"has-text-align-center\" data-align=\"center\">428941<\/td><td><strong>1.68<\/strong><\/td><td>52553<\/td><td>105189<\/td><td><strong>2.00<\/strong><\/td><\/tr><tr><td>Acephate<\/td><td class=\"has-text-align-center\" data-align=\"center\">168776<\/td><td class=\"has-text-align-center\" data-align=\"center\">300642<\/td><td><strong>1.78<\/strong><\/td><td>58418<\/td><td>104729<\/td><td><strong>1.79<\/strong><\/td><\/tr><tr><td>Omethoate<\/td><td class=\"has-text-align-center\" data-align=\"center\">579502<\/td><td class=\"has-text-align-center\" data-align=\"center\">892008<\/td><td><strong>1.54<\/strong><\/td><td>216157<\/td><td>337690<\/td><td><strong>1.56<\/strong><\/td><\/tr><tr><td>Monocrotophos<\/td><td class=\"has-text-align-center\" data-align=\"center\">140095<\/td><td class=\"has-text-align-center\" data-align=\"center\">215810<\/td><td><strong>1.54<\/strong><\/td><td>51402<\/td><td>78425<\/td><td><strong>1.53<\/strong><\/td><\/tr><tr><td>Dicrotophos<\/td><td class=\"has-text-align-center\" data-align=\"center\">340978<\/td><td class=\"has-text-align-center\" data-align=\"center\">404916<\/td><td><strong>1.19<\/strong><\/td><td>135380<\/td><td>159292<\/td><td><strong>1.18<\/strong><\/td><\/tr><tr><td>Dimethoate<\/td><td class=\"has-text-align-center\" data-align=\"center\">461156<\/td><td class=\"has-text-align-center\" data-align=\"center\">807805<\/td><td><strong>1.75<\/strong><\/td><td>188746<\/td><td>342939<\/td><td><strong>1.82<\/strong><\/td><\/tr><tr><td>Trichlorfon<\/td><td class=\"has-text-align-center\" data-align=\"center\">84233<\/td><td class=\"has-text-align-center\" data-align=\"center\">173942<\/td><td><strong>2.07<\/strong><\/td><td>34793<\/td><td>63266<\/td><td><strong>1.82<\/strong><\/td><\/tr><tr><td>Vamidothion<\/td><td class=\"has-text-align-center\" data-align=\"center\">913264<\/td><td class=\"has-text-align-center\" data-align=\"center\">1333829<\/td><td><strong>1.46<\/strong><\/td><td>354311<\/td><td>547308<\/td><td><strong>1.54<\/strong><\/td><\/tr><tr><td>Mevinphos isomer 1<\/td><td class=\"has-text-align-center\" data-align=\"center\">213632<\/td><td class=\"has-text-align-center\" data-align=\"center\">311274<\/td><td><strong>1.46<\/strong><\/td><td>82105<\/td><td>129961<\/td><td><strong>1.58<\/strong><\/td><\/tr><tr><td>Mevinphos isomer 2<\/td><td class=\"has-text-align-center\" data-align=\"center\">56093<\/td><td class=\"has-text-align-center\" data-align=\"center\">74030<\/td><td><strong>&nbsp;1.32<\/strong><\/td><td>29070<\/td><td>29802<\/td><td><strong>1.03&nbsp;<\/strong><\/td><\/tr><tr><td>Carbaryl<\/td><td class=\"has-text-align-center\" data-align=\"center\">43590<\/td><td class=\"has-text-align-center\" data-align=\"center\">39671<\/td><td><strong>0.91<\/strong><\/td><td>14563<\/td><td>11924<\/td><td><strong>0.82<\/strong><\/td><\/tr><tr><td>Isocarbophos<\/td><td class=\"has-text-align-center\" data-align=\"center\">21587<\/td><td class=\"has-text-align-center\" data-align=\"center\">33294<\/td><td><strong>1.54<\/strong><\/td><td>9062<\/td><td>11941<\/td><td><strong>1.32<\/strong><\/td><\/tr><tr><td>Dimethomorph isomer 1<\/td><td class=\"has-text-align-center\" data-align=\"center\">462425<\/td><td class=\"has-text-align-center\" data-align=\"center\">511766<\/td><td><strong>1.11<\/strong><\/td><td>166990<\/td><td>172977<\/td><td><strong>1.04<\/strong><\/td><\/tr><tr><td>Dimethomorph isomer 2<\/td><td class=\"has-text-align-center\" data-align=\"center\">896109<\/td><td class=\"has-text-align-center\" data-align=\"center\">877031<\/td><td><strong>0.98&nbsp;<\/strong><\/td><td>311657<\/td><td>328826<\/td><td><strong>1.06&nbsp;<\/strong><\/td><\/tr><tr><td>Temephos<\/td><td class=\"has-text-align-center\" data-align=\"center\">98793<\/td><td class=\"has-text-align-center\" data-align=\"center\">164310<\/td><td><strong>1.66<\/strong><\/td><td>35383<\/td><td>64751<\/td><td><strong>1.83<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u9709\u83cc\u6bd2\u7d20<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u9709\u83cc\u6bd2\u7d20\u5206\u6790\u9887\u5177\u6311\u6218\uff0c\u901a\u5e38\u9700\u8017\u8d39\u8f83\u957f\u65f6\u95f4\u5b8c\u6210\u8272\u8c31\u67f1\u5e73\u8861\u4e0e\u6761\u4ef6\u4f18\u5316\uff0c\u65b9\u53ef\u5f97\u5230\u5408\u683c\u7684\u8272\u8c31\u5cf0\u5f62\u3002\u8be5\u73b0\u8c61\u6839\u6e90\u5728\u4e8e\u9709\u83cc\u6bd2\u7d20\u7c7b\u5316\u5408\u7269\u5177\u5907\u53cd\u5e94\u6d3b\u6027\uff0c\u5206\u5b50\u7ed3\u6784\u4e2d\u5305\u542b\u9178\u6027\u3001\u6781\u6027\u57fa\u56e2\u4ee5\u53ca\u53ef\u4e0e\u91d1\u5c5e\u53d1\u751f\u87af\u5408\u4f5c\u7528\u7684\u5b98\u80fd\u56e2\u3002\u672c\u6b3e\u65b0\u578b\u60f0\u6027\u8272\u8c31\u67f1\u6574\u5408\u60f0\u6027\u67f1\u7ba1\u6750\u8d28\u4e0e\u4e13\u7528\u56fa\u5b9a\u76f8\uff0c\u80fd\u591f\u7b80\u5316\u524d\u5904\u7406\u53ca\u8272\u8c31\u68c0\u6d4b\u65b9\u6cd5\uff0c\u540c\u65f6\u63d0\u5347\u8be5\u7c7b\u5316\u5408\u7269\u7684\u54cd\u5e94\u3001\u6539\u5584\u8272\u8c31\u5cf0\u5f62\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 4\uff1a\u4f7f\u7528\u5168\u65b0\u7684 Raptor Inert Biphenyl \u8272\u8c31\u67f1\u5206\u6790\u9709\u83cc\u6bd2\u7d20\u65f6\uff0c\u65e0\u9700\u989d\u5916\u7684\u9178\u949d\u5316\u6216\u6d41\u52a8\u76f8\u6dfb\u52a0\u5242\u5373\u53ef\u83b7\u5f97\u4f18\u5f02\u7684\u5cf0\u5f62<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0552.png\" alt=\"Multi-Mycotoxin Analysis on Raptor Inert Biphenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0552<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion <\/th><th style=\"text-align: center;width: 75px\">Peak Area<\/th><th style=\"text-align: center;width: 75px\">Peak Height<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nivalenol \" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23282-20-4\/Nivalenol \" target=\"_blank\" rel=\"noopener\">Nivalenol <\/a><\/td><td class=\"oth\">0.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">295.1<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">4182<\/td><td class=\"oth\">64495<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Deoxynivalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51481-10-8\/Deoxynivalenol\" target=\"_blank\" rel=\"noopener\">Deoxynivalenol<\/a><\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">297.2<\/td><td class=\"oth\">231.0<\/td><td class=\"oth\">17346<\/td><td class=\"oth\">281906<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fusarenon-X\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23255-69-8\/Fusarenon-X\" target=\"_blank\" rel=\"noopener\">Fusarenon-X<\/a><\/td><td class=\"oth\">1.92<\/td><td class=\"oth\">10<\/td><td class=\"oth\">355.1<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">7668<\/td><td class=\"oth\">121790<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 15-Acetyldeoxynivalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88337-96-6\/15-Acetyldeoxynivalenol\" target=\"_blank\" rel=\"noopener\">15-Acetyldeoxynivalenol<\/a><\/td><td class=\"oth\">3.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">339.2<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">31369<\/td><td class=\"oth\">517570<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Acetyldeoxynivalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50722-38-8\/3-Acetyldeoxynivalenol\" target=\"_blank\" rel=\"noopener\">3-Acetyldeoxynivalenol<\/a><\/td><td class=\"oth\">3.14<\/td><td class=\"oth\">10<\/td><td class=\"oth\">339.2<\/td><td class=\"oth\">213.1<\/td><td class=\"oth\">22613<\/td><td class=\"oth\">296396<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tenuazonic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/610-88-8\/Tenuazonic acid\" target=\"_blank\" rel=\"noopener\">Tenuazonic acid<\/a><\/td><td class=\"oth\">4.11<\/td><td class=\"oth\">10<\/td><td class=\"oth\">198.1<\/td><td class=\"oth\">125.0<\/td><td class=\"oth\">47828<\/td><td class=\"oth\">197658<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Altenuene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29752-43-0\/Altenuene\" target=\"_blank\" rel=\"noopener\">Altenuene<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">10<\/td><td class=\"oth\">293.2<\/td><td class=\"oth\">257.1<\/td><td class=\"oth\">113850<\/td><td class=\"oth\">2059699<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alternariol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/641-38-3\/Alternariol\" target=\"_blank\" rel=\"noopener\">Alternariol<\/a><\/td><td class=\"oth\">5.27<\/td><td class=\"oth\">10<\/td><td class=\"oth\">259.0<\/td><td class=\"oth\">185.1<\/td><td class=\"oth\">73272<\/td><td class=\"oth\">1302192<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergosine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/561-94-4\/Ergosine\" target=\"_blank\" rel=\"noopener\">Ergosine<\/a><\/td><td class=\"oth\">5.28<\/td><td class=\"oth\">10<\/td><td class=\"oth\">548.4<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">486620<\/td><td class=\"oth\">9366601<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Citrinin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/518-75-2\/Citrinin\" target=\"_blank\" rel=\"noopener\">Citrinin<\/a><\/td><td class=\"oth\">5.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">251.2<\/td><td class=\"oth\">233.1<\/td><td class=\"oth\">1007880<\/td><td class=\"oth\">9828889<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergosinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/596-88-3\/Ergosinine\" target=\"_blank\" rel=\"noopener\">Ergosinine<\/a><\/td><td class=\"oth\">5.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">548.4<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">496734<\/td><td class=\"oth\">8740527<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116355-83-0\/Fumonisin B1\" target=\"_blank\" rel=\"noopener\">Fumonisin B1<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">10<\/td><td class=\"oth\">722.5<\/td><td class=\"oth\">352.3<\/td><td class=\"oth\">122878<\/td><td class=\"oth\">2415567<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diacetoxyscirpenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2270-40-8\/Diacetoxyscirpenol\" target=\"_blank\" rel=\"noopener\">Diacetoxyscirpenol<\/a><\/td><td class=\"oth\">5.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">384.2<\/td><td class=\"oth\">247.1<\/td><td class=\"oth\">68139<\/td><td class=\"oth\">1208825<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergotamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113-15-5\/Ergotamine\" target=\"_blank\" rel=\"noopener\">Ergotamine<\/a><\/td><td class=\"oth\">5.71<\/td><td class=\"oth\">10<\/td><td class=\"oth\">582.4<\/td><td class=\"oth\">223.2<\/td><td class=\"oth\">493003<\/td><td class=\"oth\">9274155<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocornine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/564-36-3\/Ergocornine\" target=\"_blank\" rel=\"noopener\">Ergocornine<\/a><\/td><td class=\"oth\">5.85<\/td><td class=\"oth\">10<\/td><td class=\"oth\">562.4<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">387025<\/td><td class=\"oth\">7732744<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergotaminine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/639-81-6\/Ergotaminine\" target=\"_blank\" rel=\"noopener\">Ergotaminine<\/a><\/td><td class=\"oth\">5.96<\/td><td class=\"oth\">10<\/td><td class=\"oth\">582.4<\/td><td class=\"oth\">223.2<\/td><td class=\"oth\">462119<\/td><td class=\"oth\">9237991<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for HT-2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26934-87-2\/HT-2\" target=\"_blank\" rel=\"noopener\">HT-2<\/a><\/td><td class=\"oth\">6.13<\/td><td class=\"oth\">10<\/td><td class=\"oth\">447.2<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">15221<\/td><td class=\"oth\">323765<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocryptine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/511-09-1\/Ergocryptine\" target=\"_blank\" rel=\"noopener\">Ergocryptine<\/a><\/td><td class=\"oth\">6.19<\/td><td class=\"oth\">10<\/td><td class=\"oth\">576.4<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">522204<\/td><td class=\"oth\">11360838<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B3\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1422359-85-0\/Fumonisin B3\" target=\"_blank\" rel=\"noopener\">Fumonisin B3<\/a><\/td><td class=\"oth\">6.23<\/td><td class=\"oth\">10<\/td><td class=\"oth\">706.4<\/td><td class=\"oth\">336.2<\/td><td class=\"oth\">143302<\/td><td class=\"oth\">3444421<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocristine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/511-08-0\/Ergocristine\" target=\"_blank\" rel=\"noopener\">Ergocristine<\/a><\/td><td class=\"oth\">6.44<\/td><td class=\"oth\">10<\/td><td class=\"oth\">610.4<\/td><td class=\"oth\">223.2<\/td><td class=\"oth\">195562<\/td><td class=\"oth\">4450058<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116355-84-1\/Fumonisin B2\" target=\"_blank\" rel=\"noopener\">Fumonisin B2<\/a><\/td><td class=\"oth\">6.59<\/td><td class=\"oth\">10<\/td><td class=\"oth\">706.4<\/td><td class=\"oth\">336.2<\/td><td class=\"oth\">151719<\/td><td class=\"oth\">3869822<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tentoxin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28540-82-1\/Tentoxin\" target=\"_blank\" rel=\"noopener\">Tentoxin<\/a><\/td><td class=\"oth\">6.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">415.2<\/td><td class=\"oth\">312.2<\/td><td class=\"oth\">95175<\/td><td class=\"oth\">2131906<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Zearalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36455-72-8\/\u03b1-Zearalenol\" target=\"_blank\" rel=\"noopener\">\u03b1-Zearalenol<\/a><\/td><td class=\"oth\">6.91<\/td><td class=\"oth\">10<\/td><td class=\"oth\">303.1<\/td><td class=\"oth\">285.1<\/td><td class=\"oth\">30224<\/td><td class=\"oth\">702420<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocorninine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/564-37-4\/Ergocorninine\" target=\"_blank\" rel=\"noopener\">Ergocorninine<\/a><\/td><td class=\"oth\">6.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">562.4<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">704029<\/td><td class=\"oth\">14389283<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7241-98-7\/Aflatoxin G2\" target=\"_blank\" rel=\"noopener\">Aflatoxin G2<\/a><\/td><td class=\"oth\">6.97<\/td><td class=\"oth\">10<\/td><td class=\"oth\">331.2<\/td><td class=\"oth\">189.0<\/td><td class=\"oth\">262824<\/td><td class=\"oth\">5274353<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for T-2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-31-7\/T-2\" target=\"_blank\" rel=\"noopener\">T-2<\/a><\/td><td class=\"oth\">7.09<\/td><td class=\"oth\">10<\/td><td class=\"oth\">489.2<\/td><td class=\"oth\">387.1<\/td><td class=\"oth\">56535<\/td><td class=\"oth\">1394735<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocryptinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/511-10-4\/Ergocryptinine\" target=\"_blank\" rel=\"noopener\">Ergocryptinine<\/a><\/td><td class=\"oth\">7.18<\/td><td class=\"oth\">10<\/td><td class=\"oth\">576.4<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">778972<\/td><td class=\"oth\">16765348<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocristinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/511-07-9\/Ergocristinine\" target=\"_blank\" rel=\"noopener\">Ergocristinine<\/a><\/td><td class=\"oth\">7.40<\/td><td class=\"oth\">10<\/td><td class=\"oth\">610.4<\/td><td class=\"oth\">223.2<\/td><td class=\"oth\">1583053<\/td><td class=\"oth\">32975663<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1165-39-5\/Aflatoxin G1\" target=\"_blank\" rel=\"noopener\">Aflatoxin G1<\/a><\/td><td class=\"oth\">7.45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">329.1<\/td><td class=\"oth\">199.7<\/td><td class=\"oth\">304389<\/td><td class=\"oth\">6102959<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zearalenone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17924-92-4\/Zearalenone\" target=\"_blank\" rel=\"noopener\">Zearalenone<\/a><\/td><td class=\"oth\">7.59<\/td><td class=\"oth\">10<\/td><td class=\"oth\">319.2<\/td><td class=\"oth\">283.1<\/td><td class=\"oth\">37162<\/td><td class=\"oth\">927455<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alternariol monomethylether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26894-49-5\/Alternariol monomethylether\" target=\"_blank\" rel=\"noopener\">Alternariol monomethylether<\/a><\/td><td class=\"oth\">7.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">273.0<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">31024<\/td><td class=\"oth\">640689<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7220-81-7\/Aflatoxin B2\" target=\"_blank\" rel=\"noopener\">Aflatoxin B2<\/a><\/td><td class=\"oth\">7.63<\/td><td class=\"oth\">10<\/td><td class=\"oth\">315.1<\/td><td class=\"oth\">287.0<\/td><td class=\"oth\">295648<\/td><td class=\"oth\">5724754<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1162-65-8\/Aflatoxin B1\" target=\"_blank\" rel=\"noopener\">Aflatoxin B1<\/a><\/td><td class=\"oth\">8.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">313.2<\/td><td class=\"oth\">241.1<\/td><td class=\"oth\">223520<\/td><td class=\"oth\">4425821<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ochratoxin A\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-47-9\/Ochratoxin A\" target=\"_blank\" rel=\"noopener\">Ochratoxin A<\/a><\/td><td class=\"oth\">8.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">404.1<\/td><td class=\"oth\">239.0<\/td><td class=\"oth\">190060<\/td><td class=\"oth\">4411953<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Inert Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A12-T\" rel=\"noopener\">cat.# 9309A12-T<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>60 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>Aflatoxins standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34121\" rel=\"noopener\">cat.# 34121<\/a>)<\/td><\/tr><tr><td><\/td><td>Ochratoxin A standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34122\" rel=\"noopener\">cat.# 34122<\/a>)<\/td><\/tr><tr><td><\/td><\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>50:50 Water:methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.05% formic acid  <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.05% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><tr><td>5.00<\/td><td>0.4<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td>9.00<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>9.01<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><tr><td>11.0<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>440 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ-S<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY UPLC I-Class<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td><br \/><br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34121<\/li><li>34122<\/li><li>9309A12-T<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>mycotoxin<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0552.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 5\uff1a\u5728\u672c\u6b21\u4f0f\u9a6c\u6bd2\u7d20\uff08fumonisins\uff09\u5206\u6790\u4e2d\uff0c\u5168\u65b0\u7684 Raptor Inert Biphenyl \u8272\u8c31\u67f1\u8f83\u4f20\u7edf\u4e0d\u9508\u94a2\u67f1\u5b9e\u73b0\u4e86\u5cf0\u9762\u79ef\u7684\u663e\u8457\u63d0\u5347<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0554.png\" alt=\"Comparison of Fumonisin B Compounds on Raptor Inert Biphenyl and Raptor Biphenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0554<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0554.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 6\uff1a\u4f0f\u9a6c\u6bd2\u7d20\u5206\u6790\u7684\u5cf0\u9762\u79ef\u548c\u5cf0\u9ad8\u5747\u5927\u5e45\u63d0\u5347<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0556.png\" alt=\"Comparison of Fumonisin B Compounds on Raptor Inert Biphenyl and Raptor Biphenyl\u2014Overlay View\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0556<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0556.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8868 II\uff1a\u5728\u672c\u6b21\u9709\u83cc\u6bd2\u7d20\u5206\u6790\u4e2d\uff0c\u5168\u65b0\u7684\u60f0\u6027\u67f1\u8f83\u4f20\u7edf\u8272\u8c31\u67f1\u5cf0\u9ad8\u6700\u591a\u63d0\u5347 10 \u500d<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>\u5316\u5408\u7269<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\"><strong>\u5cf0\u9762\u79ef<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\"><strong>\u5cf0\u9ad8<\/strong><\/td><\/tr><tr><td><strong>\u4e0d\u9508\u94a2<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>\u60f0\u6027<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>\u9762\u79ef\u6bd4 (\u60f0\u6027\/\u4e0d\u9508\u94a2)<\/strong><\/td><td><strong>\u4e0d\u9508\u94a2<\/strong><\/td><td><strong>\u60f0\u6027<\/strong><\/td><td><strong>\u5cf0\u9ad8\u6bd4 (\u60f0\u6027\/\u4e0d\u9508\u94a2)<\/strong><\/td><\/tr><tr><td>Fumonisin B1<\/td><td class=\"has-text-align-center\" data-align=\"center\">32578<\/td><td class=\"has-text-align-center\" data-align=\"center\">122878<\/td><td><strong>3.77<\/strong><\/td><td>399544<\/td><td>2415567<\/td><td><strong>6.05<\/strong><\/td><\/tr><tr><td>Fumonisin B2<\/td><td class=\"has-text-align-center\" data-align=\"center\">23427<\/td><td class=\"has-text-align-center\" data-align=\"center\">151719<\/td><td><strong>6.48<\/strong><\/td><td>383130<\/td><td>3869822<\/td><td><strong>10.10<\/strong><\/td><\/tr><tr><td>Fumonisin B3<\/td><td class=\"has-text-align-center\" data-align=\"center\">29864<\/td><td class=\"has-text-align-center\" data-align=\"center\">143302<\/td><td><strong>4.80<\/strong><\/td><td>472279<\/td><td>3444421<\/td><td><strong>7.29<\/strong><\/td><\/tr><tr><td>Ergocristine<\/td><td class=\"has-text-align-center\" data-align=\"center\">171197<\/td><td class=\"has-text-align-center\" data-align=\"center\">195562<\/td><td><strong>1.14<\/strong><\/td><td>3865898<\/td><td>4450058<\/td><td><strong>1.15<\/strong><\/td><\/tr><tr><td>Ergocristinine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1393116<\/td><td class=\"has-text-align-center\" data-align=\"center\">1583053<\/td><td><strong>1.14<\/strong><\/td><td>29212317<\/td><td>32975663<\/td><td><strong>1.13<\/strong><\/td><\/tr><tr><td>Ergotamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">433635<\/td><td class=\"has-text-align-center\" data-align=\"center\">493003<\/td><td><strong>1.14<\/strong><\/td><td>8149518<\/td><td>9274156<\/td><td><strong>1.14<\/strong><\/td><\/tr><tr><td>Ergotaminine<\/td><td class=\"has-text-align-center\" data-align=\"center\">397370<\/td><td class=\"has-text-align-center\" data-align=\"center\">462119<\/td><td><strong>1.16<\/strong><\/td><td>7885403<\/td><td>9237991<\/td><td><strong>1.17<\/strong><\/td><\/tr><tr><td>Ergocryptine<\/td><td class=\"has-text-align-center\" data-align=\"center\">446481<\/td><td class=\"has-text-align-center\" data-align=\"center\">522204<\/td><td><strong>1.17<\/strong><\/td><td>9671753<\/td><td>11360839<\/td><td><strong>1.17<\/strong><\/td><\/tr><tr><td>Ergocryptinine<\/td><td class=\"has-text-align-center\" data-align=\"center\">658788<\/td><td class=\"has-text-align-center\" data-align=\"center\">778972<\/td><td><strong>1.18<\/strong><\/td><td>13680420<\/td><td>16765348<\/td><td><strong>1.23<\/strong><\/td><\/tr><tr><td>Ergocornine<\/td><td class=\"has-text-align-center\" data-align=\"center\">370509<\/td><td class=\"has-text-align-center\" data-align=\"center\">387025<\/td><td><strong>1.04<\/strong><\/td><td>7248981<\/td><td>7732744<\/td><td><strong>1.07<\/strong><\/td><\/tr><tr><td>Ergocorninine<\/td><td class=\"has-text-align-center\" data-align=\"center\">590167<\/td><td class=\"has-text-align-center\" data-align=\"center\">704029<\/td><td><strong>1.19<\/strong><\/td><td>12052359<\/td><td>14389283<\/td><td><strong>1.19<\/strong><\/td><\/tr><tr><td>Ergosine<\/td><td class=\"has-text-align-center\" data-align=\"center\">445243<\/td><td class=\"has-text-align-center\" data-align=\"center\">486620<\/td><td><strong>1.09<\/strong><\/td><td>8630932<\/td><td>9366602<\/td><td><strong>1.09<\/strong><\/td><\/tr><tr><td>Ergosinine<\/td><td class=\"has-text-align-center\" data-align=\"center\">439026<\/td><td class=\"has-text-align-center\" data-align=\"center\">496734<\/td><td><strong>1.13<\/strong><\/td><td>7820785<\/td><td>8740527<\/td><td><strong>1.12<\/strong><\/td><\/tr><tr><td>T-2<\/td><td class=\"has-text-align-center\" data-align=\"center\">43286<\/td><td class=\"has-text-align-center\" data-align=\"center\">56535<\/td><td><strong>1.31<\/strong><\/td><td>1046233<\/td><td>1394735<\/td><td><strong>1.33<\/strong><\/td><\/tr><tr><td>HT-2<\/td><td class=\"has-text-align-center\" data-align=\"center\">10183<\/td><td class=\"has-text-align-center\" data-align=\"center\">15221<\/td><td><strong>1.49<\/strong><\/td><td>216703<\/td><td>323765<\/td><td><strong>1.49<\/strong><\/td><\/tr><tr><td>Tentoxin<\/td><td class=\"has-text-align-center\" data-align=\"center\">70973<\/td><td class=\"has-text-align-center\" data-align=\"center\">95175<\/td><td><strong>1.34<\/strong><\/td><td>1577164<\/td><td>2131907<\/td><td><strong>1.35<\/strong><\/td><\/tr><tr><td>Ochratoxin<\/td><td class=\"has-text-align-center\" data-align=\"center\">173686<\/td><td class=\"has-text-align-center\" data-align=\"center\">190060<\/td><td><strong>1.09<\/strong><\/td><td>4039682<\/td><td>4411953<\/td><td><strong>1.09<\/strong><\/td><\/tr><tr><td>Diacetoxyscirpenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">47850<\/td><td class=\"has-text-align-center\" data-align=\"center\">68139<\/td><td><strong>1.42<\/strong><\/td><td>846403<\/td><td>1208826<\/td><td><strong>1.43<\/strong><\/td><\/tr><tr><td>Fusarenone X<\/td><td class=\"has-text-align-center\" data-align=\"center\">3865<\/td><td class=\"has-text-align-center\" data-align=\"center\">7668<\/td><td><strong>1.98<\/strong><\/td><td>60409<\/td><td>121790<\/td><td><strong>2.02<\/strong><\/td><\/tr><tr><td>15-acetyl-DON<\/td><td class=\"has-text-align-center\" data-align=\"center\">17055<\/td><td class=\"has-text-align-center\" data-align=\"center\">31369<\/td><td><strong>1.84<\/strong><\/td><td>269862<\/td><td>517570<\/td><td><strong>1.92<\/strong><\/td><\/tr><tr><td>3-acetyldeoxyvinalenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">13353<\/td><td class=\"has-text-align-center\" data-align=\"center\">22613<\/td><td><strong>1.69<\/strong><\/td><td>179204<\/td><td>296396<\/td><td><strong>1.65<\/strong><\/td><\/tr><tr><td>Aflatoxin G2<\/td><td class=\"has-text-align-center\" data-align=\"center\">171597<\/td><td class=\"has-text-align-center\" data-align=\"center\">262824<\/td><td><strong>1.53<\/strong><\/td><td>3429501<\/td><td>5274354<\/td><td><strong>1.54<\/strong><\/td><\/tr><tr><td>Aflatoxin G1<\/td><td class=\"has-text-align-center\" data-align=\"center\">224058<\/td><td class=\"has-text-align-center\" data-align=\"center\">304389<\/td><td><strong>1.36<\/strong><\/td><td>4607959<\/td><td>6102959<\/td><td><strong>1.32<\/strong><\/td><\/tr><tr><td>ZON<\/td><td class=\"has-text-align-center\" data-align=\"center\">25617<\/td><td class=\"has-text-align-center\" data-align=\"center\">37162<\/td><td><strong>1.45<\/strong><\/td><td>656915<\/td><td>927455<\/td><td><strong>1.41<\/strong><\/td><\/tr><tr><td>Aflatoxin B2<\/td><td class=\"has-text-align-center\" data-align=\"center\">159389<\/td><td class=\"has-text-align-center\" data-align=\"center\">295648<\/td><td><strong>1.85<\/strong><\/td><td>3462489<\/td><td>5724754<\/td><td><strong>1.65<\/strong><\/td><\/tr><tr><td>Aflatoxin B1<\/td><td class=\"has-text-align-center\" data-align=\"center\">265935<\/td><td class=\"has-text-align-center\" data-align=\"center\">223520<\/td><td><strong>0.84<\/strong><\/td><td>5335576<\/td><td>4425821<\/td><td><strong>0.83<\/strong><\/td><\/tr><tr><td>Alpha-zearalenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">16202<\/td><td class=\"has-text-align-center\" data-align=\"center\">30224<\/td><td><strong>1.87<\/strong><\/td><td>382092<\/td><td>702420<\/td><td><strong>1.84<\/strong><\/td><\/tr><tr><td>Deoxynivalenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">6935<\/td><td class=\"has-text-align-center\" data-align=\"center\">17346<\/td><td><strong>2.50<\/strong><\/td><td>117927<\/td><td>281906<\/td><td><strong>2.39<\/strong><\/td><\/tr><tr><td>Nivalenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1790<\/td><td class=\"has-text-align-center\" data-align=\"center\">4182<\/td><td><strong>2.34<\/strong><\/td><td>25276<\/td><td>64495<\/td><td><strong>2.55<\/strong><\/td><\/tr><tr><td>Altenuene<\/td><td class=\"has-text-align-center\" data-align=\"center\">63224<\/td><td class=\"has-text-align-center\" data-align=\"center\">113850<\/td><td><strong>1.80<\/strong><\/td><td>1187958<\/td><td>2059700<\/td><td><strong>1.73<\/strong><\/td><\/tr><tr><td>Alternariol monomethyl ether<\/td><td class=\"has-text-align-center\" data-align=\"center\">19537<\/td><td class=\"has-text-align-center\" data-align=\"center\">31024<\/td><td><strong>1.59<\/strong><\/td><td>428922<\/td><td>640689<\/td><td><strong>1.49<\/strong><\/td><\/tr><tr><td>Alternariol<\/td><td class=\"has-text-align-center\" data-align=\"center\">48204<\/td><td class=\"has-text-align-center\" data-align=\"center\">73272<\/td><td><strong>1.52<\/strong><\/td><td>837410<\/td><td>1302192<\/td><td><strong>1.56<\/strong><\/td><\/tr><tr><td>Citrinin<\/td><td class=\"has-text-align-center\" data-align=\"center\">499900<\/td><td class=\"has-text-align-center\" data-align=\"center\">1007880<\/td><td><strong>2.02<\/strong><\/td><td>5031182<\/td><td>9828890<\/td><td><strong>1.95<\/strong><\/td><\/tr><tr><td>Tenuazonic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">21503<\/td><td class=\"has-text-align-center\" data-align=\"center\">47828<\/td><td><strong>2.22<\/strong><\/td><td>89293<\/td><td>197658<\/td><td><strong>2.21<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u7532\u57fa\u4e19\u4e8c\u9178\uff08MMA\uff09<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7532\u57fa\u4e19\u4e8c\u9178\u7684\u5206\u6790\u662f\u4e34\u5e8a\u5b9e\u9a8c\u5ba4\u9274\u522b\u7ef4\u751f\u7d20 B12 \u7f3a\u4e4f\u7684\u4e00\u9879\u91cd\u8981\u68c0\u6d4b\u3002\u5728\u7532\u57fa\u4e19\u4e8c\u9178\u68c0\u6d4b\u4e2d\u4f7f\u7528\u60f0\u6027\u786c\u4ef6\u65f6\uff0c\u7075\u654f\u5ea6\u8f83\u5e38\u89c4\u786c\u4ef6\u63d0\u5347\u4e86 40%\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 7\uff1a\u4e0e\u4f20\u7edf\u4e0d\u9508\u94a2\u8272\u8c31\u67f1\u76f8\u6bd4\uff0cForce Inert C18 \u8272\u8c31\u67f1\u663e\u8457\u63d0\u5347\u4e86\u7532\u57fa\u4e19\u4e8c\u9178\u7684\u7075\u654f\u5ea6<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ex0524.png\" alt=\"Comparison of Methylmalonic Acid (MMA) on Force Inert C18 and Force C18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EX0524<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MMA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/516-05-2\/MMA\" target=\"_blank\" rel=\"noopener\">MMA<\/a><\/td><td class=\"oth\">116.97<\/td><td class=\"oth\">72.97<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>35 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>50:50 Water:methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.5% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.5% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.7<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>0.50<\/td><td>0.7<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>3.00<\/td><td>0.7<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>3.01<\/td><td>0.7<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>5.00<\/td><td>0.7<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>275 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ Absolute<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Waters Zspray ESI <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY Premier<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Columns are:<br \/>\u2022 Force C18 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/963431E\" rel=\"noopener\">cat.# 963431E<\/a>)<br \/>\u2022 Force Inert C18 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/963431E-T\" rel=\"noopener\">cat.# 963431E-T<\/a>)<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>963431E<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ex0524.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u517d\u836f<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u98df\u54c1\u6837\u54c1\uff08\u5c24\u5176\u662f\u8089\u7c7b\u3001\u9c7c\u7c7b\u548c\u86cb\u7c7b\uff09\u4e2d\u9274\u5b9a\u517d\u836f\uff0c\u662f\u4f9d\u636e FDA \u548c\u6b27\u76df\u51c6\u5219\u786e\u4fdd\u98df\u54c1\u5b89\u5168\u7684\u4e00\u9879\u91cd\u8981\u68c0\u6d4b\u3002\u5728\u5bf9 10 \u79cd\u5e38\u89c1\u517d\u836f\u7684\u5206\u6790\u4e2d\uff0c\u4e0e\u4f20\u7edf\u4e0d\u9508\u94a2\u67f1\u76f8\u6bd4\uff0c\u4f7f\u7528\u60f0\u6027\u67f1\u53ef\u663e\u8457\u63d0\u5347\u5206\u6790\u7269\u54cd\u5e94\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong><em>\u56fe 8\uff1a\u5cf0\u5217\u8868\u2014\u2014Raptor Inert C18 \u4e0a\u7684\u517d\u836f<\/em><\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0557.png\" alt=\"Comparison of Vet Drugs on Raptor Inert C18 and Raptor C18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0557<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">Precursor Ion<\/th><th style=\"text-align: center;width: 50px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lincomycin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/154-21-2\/Lincomycin\" target=\"_blank\" rel=\"noopener\">Lincomycin<\/a><\/td><td class=\"oth\">407.00<\/td><td class=\"oth\">359.00<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norfloxacin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70458-96-7\/Norfloxacin\" target=\"_blank\" rel=\"noopener\">Norfloxacin<\/a><\/td><td class=\"oth\">320.00<\/td><td class=\"oth\">276.00<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tulathromycin A\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/217500-96-4\/Tulathromycin A\" target=\"_blank\" rel=\"noopener\">Tulathromycin A<\/a><\/td><td class=\"oth\">806.60<\/td><td class=\"oth\">577.00<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\">Cefazolin<\/td><td class=\"oth\">455.00<\/td><td class=\"oth\">323.00<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Difloxacin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98106-17-3\/Difloxacin\" target=\"_blank\" rel=\"noopener\">Difloxacin<\/a><\/td><td class=\"oth\">400.00<\/td><td class=\"oth\">356.00<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\">Pirlimycin<\/td><td class=\"oth\">411.00<\/td><td class=\"oth\">363.00<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Gamithromycin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/145435-72-9\/Gamithromycin\" target=\"_blank\" rel=\"noopener\">Gamithromycin<\/a><\/td><td class=\"oth\">777.00<\/td><td class=\"oth\">619.00<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Erythromycin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/114-07-8\/Erythromycin\" target=\"_blank\" rel=\"noopener\">Erythromycin<\/a><\/td><td class=\"oth\">734.00<\/td><td class=\"oth\">576.00<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Virginiamycin M1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/21411-53-0\/Virginiamycin M1\" target=\"_blank\" rel=\"noopener\">Virginiamycin M1<\/a><\/td><td class=\"oth\">526.00<\/td><td class=\"oth\">508.00<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cloxacillin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61-72-3\/Cloxacillin\" target=\"_blank\" rel=\"noopener\">Cloxacillin<\/a><\/td><td class=\"oth\">436.00<\/td><td class=\"oth\">277.05<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>35 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>50:50 Methanol:water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>2 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Acetonitrile, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>4.50<\/td><td>0.4<\/td><td>65<\/td><td>35<\/td><\/tr><tr><td>7.00<\/td><td>0.4<\/td><td>45<\/td><td>55<\/td><\/tr><tr><td>7.01<\/td><td>0.4<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>9.00<\/td><td>0.4<\/td><td>90<\/td><td>10<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>283 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu 8060 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Columns are:<br \/>\u2022 Raptor C18 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A12\" rel=\"noopener\">cat.# 9304A12<\/a>)<br \/>\u2022 Raptor Inert C18 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A12-T\" rel=\"noopener\">cat.# 9304A12-T<\/a>)<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0557.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u4f7f\u7528\u60f0\u6027\u4fdd\u62a4\u67f1\u589e\u5f3a\u6027\u80fd\u4e0e\u9632\u62a4<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u60f0\u6027\u4fdd\u62a4\u67f1\u4e0d\u4ec5\u627f\u62c5\u7740\u4e3a\u6db2\u76f8\u7cfb\u7edf\u63d0\u4f9b\u9632\u62a4\u7684\u91cd\u8981\u804c\u8d23\uff0c\u5728\u5206\u6790\u91d1\u5c5e\u654f\u611f\u5316\u5408\u7269\u65f6\u4e5f\u5177\u6709\u66f4\u4f18\u5f02\u7684\u6027\u80fd\u3002\u5728\u4e00\u6b21\u9709\u83cc\u6bd2\u7d20\u5206\u6790\u4e2d\uff0c\u51e0\u4e4e\u6240\u6709\u5316\u5408\u7269\u7684\u56de\u6536\u7387\u90fd\u6709\u6240\u63d0\u9ad8\uff0c\u5176\u4e2d\u5173\u952e\u7684\u4f0f\u9a6c\u6bd2\u7d20 B1\u3001B2\u3001B3\u56de\u6536\u7387\u63d0\u5347\u6548\u679c\u5c24\u4e3a\u7a81\u51fa\u3002\u66f4\u6362\u60f0\u6027\u8272\u8c31\u786c\u4ef6\u4f53\u7cfb\u540e\uff0c\u5404\u7c7b\u5316\u5408\u7269\u7684\u8272\u8c31\u5cf0\u5f62\u5f97\u5230\u663e\u8457\u4f18\u5316\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 9\uff1a\u4e0e\u4e0d\u9508\u94a2 LC \u8272\u8c31\u67f1\u548c\u4fdd\u62a4\u67f1\u76f8\u6bd4\uff0c\u4f7f\u7528\u60f0\u6027 LC \u8272\u8c31\u67f1\u548c\u4fdd\u62a4\u67f1\u53ef\u663e\u8457\u63d0\u9ad8\u5cf0\u9ad8<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"432\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-09-1024x432.jpg\" alt=\"\" class=\"wp-image-21678\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-09-1024x432.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-09-300x126.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-09-768x324.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-09-1536x648.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-09.jpg 1793w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">* \uff08\u4f7f\u7528\u60f0\u6027\u8272\u8c31\u67f1\u548c\u60f0\u6027\u4fdd\u62a4\u67f1\u65f6\u7684\u5cf0\u9ad8\uff09\/\uff08\u4f7f\u7528\u4e0d\u9508\u94a2\u8272\u8c31\u67f1\u548c\u4e0d\u9508\u94a2\u4fdd\u62a4\u67f1\u65f6\u7684\u5cf0\u9ad8\uff09\u00d7 100%<\/p>\n\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><em>\u56fe 10\uff1a\u4f7f\u7528\u60f0\u6027 LC \u8272\u8c31\u67f1\u642d\u914d\u60f0\u6027\u4fdd\u62a4\u67f1\uff0c\u4f0f\u9a6c\u6bd2\u7d20 B1\u3001B2\u3001B3 \u7684\u5cf0\u5f62\u83b7\u5f97\u4e86\u5927\u5e45\u6539\u5584<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"616\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-10-1024x616.jpg\" alt=\"\" class=\"wp-image-21684\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-10-1024x616.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-10-300x181.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-10-768x462.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnss4155-10.jpg 1394w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u5353\u8d8a\u7684\u60f0\u6027\uff0c\u642d\u914d\u5353\u8d8a\u7684\u56fa\u5b9a\u76f8<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6211\u4eec\u5c06\u5728\u4ee5\u4e0b\u4e09\u79cd\u8272\u8c31\u67f1\u7c7b\u578b\u4e0a\u63a8\u51fa\u60f0\u6027 LC \u67f1\u6280\u672f\uff1aRaptor Biphenyl\u3001Raptor ARC-18 \u548c Force Biphenyl\u3002\u8fd9\u4e9b\u65b0\u578b\u8272\u8c31\u67f1\u6709\u52a9\u4e8e\u5c06\u60f0\u6027\u67f1\u6280\u672f\u7684\u4f18\u52bf\u5e26\u7ed9\u66f4\u591a\u4e13\u6ce8\u4e8e\u5c0f\u5206\u5b50 LC-MS\/MS \u5de5\u4f5c\u6d41\u7a0b\u7684\u5b9e\u9a8c\u5ba4\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Raptor <strong>\u6db2\u76f8\u8272\u8c31\u67f1<\/strong><\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"142\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2013-raptor-2.png\" alt=\"\" class=\"wp-image-29556\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2013-raptor-2.png 400w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2013-raptor-2-300x107.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/c\/1763\" target=\"_blank\" rel=\"noopener\">Raptor \u6db2\u76f8\u8272\u8c31\u67f1<\/a> \u878d\u5408 2.7 \u03bcm \u8868\u9762\u591a\u5b54\u9897\u7c92\uff08SPP\uff09\u7684\u5feb\u901f\u5206\u79bb\u4f18\u52bf\u4e0e\u8d85\u9009\u62e9\u6027\u6db2\u76f8\u8272\u8c31\uff08USLC\uff09\u6280\u672f\u7684\u9ad8\u5206\u79bb\u5ea6\u7279\u6027\uff0c\u53ef\u5728\u5e38\u89c4\u9ad8\u6548\u6db2\u76f8\u8272\u8c31\u4eea\u4e0a\u4f18\u5316\u7ec4\u5206\u5206\u79bb\u6548\u679c\u3001\u7f29\u77ed\u6574\u4f53\u68c0\u6d4b\u65f6\u957f\u3002\u82e5\u5feb\u901f\u5206\u6790\u4e3a\u6838\u5fc3\u5b9e\u9a8c\u9700\u6c42\uff0cRestek\u63a8\u8350\u9009\u7528 Raptor \u7cfb\u5217\u6db2\u76f8\u8272\u8c31\u67f1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u70b9\u51fb\u94fe\u63a5\u4e86\u89e3\u66f4\u591a\uff1a&nbsp;<a href=\"https:\/\/www.restek.com\/Raptor\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/Raptor<\/a><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Raptor Inert Biphenyl<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u8054\u82ef\u952e\u5408\u76f8\u4e3aRestek\u9996\u521b\u56fa\u5b9a\u76f8\uff0c\u4e5f\u662f\u5e94\u7528\u6700\u5e7f\u6cdb\u7684\u6db2\u76f8\u8272\u8c31\u56fa\u5b9a\u76f8\uff0c\u9488\u5bf9 C18 \u70f7\u57fa\u952e\u5408\u76f8\u3001\u5176\u4f59\u82ef\u57fa\u5316\u5b66\u56fa\u5b9a\u76f8\u96be\u4ee5\u5b9e\u73b0\u6709\u6548\u5206\u79bb\u6216\u7ec4\u5206\u63d0\u524d\u6d17\u8131\u7684\u76ee\u6807\u7269\u5177\u5907\u4f18\u5f02\u5206\u79bb\u6027\u80fd\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Raptor Inert C18<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u8fd9\u6b3e\u4f20\u7edf\u5c01\u7aef C18 \u662fRaptor \u7cfb\u5217\u4e2d\u758f\u6c34\u4fdd\u7559\u80fd\u529b\u6700\u5f3a\u7684\uff0c\u5e76\u517c\u5bb9\u4ece\u4e2d\u7b49\u9178\u6027\u5230\u4e2d\u6027\uff08pH 2\u20138\uff09\u7684\u591a\u79cd\u6d41\u52a8\u76f8\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Raptor Inert ARC-18<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u8d28\u8c31\u6240\u9700\u7684\u82db\u523b\u9178\u6027\u6d41\u52a8\u76f8\u4e2d\uff0c\u5177\u6709\u5747\u8861\u7684\u4fdd\u7559\u7279\u6027\uff0c\u540c\u65f6\u907f\u514d\u666e\u901a C18 \u5b58\u5728\u7684\u5404\u7c7b\u7f3a\u9677\u3002\u5373\u4f7f\u5728 pH\u22642.0 \u7684\uff1f\u957f\u671f\u5faa\u73af\u4f7f\u7528\uff0c\u5177\u5907\u7a7a\u95f4\u4f4d\u963b\u4fdd\u62a4\u7ed3\u6784\u7684 ARC-18 \u586b\u6599\u4ecd\u53ef\u7ef4\u6301\u7a33\u5b9a\u7684\u4fdd\u7559\u5f3a\u5ea6\u3001\u5bf9\u79f0\u5cf0\u5f62\u4e0e\u7a33\u5b9a\u54cd\u5e94\u503c\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Force <strong>\u6db2\u76f8\u8272\u8c31\u67f1<\/strong><\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"89\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Force-300x89.jpg\" alt=\"\" class=\"wp-image-28314\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Force-300x89.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Force-768x228.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Force.jpg 929w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Force \u5168\u591a\u5b54\u9897\u7c92\uff08FPP\uff09\u6db2\u76f8\u8272\u8c31\u67f1\u4e13\u4e3a\u627f\u53d7\u9ad8\u538b\u3001\u9ad8\u8d1f\u8377\u6761\u4ef6\u800c\u8bbe\u8ba1\u548c\u5236\u9020\u3002\u8be5\u8272\u8c31\u67f1\u8010\u7528\u6027\u5f3a\u3001\u5206\u6790\u91cd\u73b0\u6027\u4f18\u5f02\uff0c\u4ea7\u54c1\u6027\u80fd\u7a33\u5b9a\u53ef\u9760\uff0c\u4e14\u914d\u5957\u54c1\u724c\u767e\u5206\u767e\u6ee1\u610f\u54c1\u8d28\u4fdd\u969c\u670d\u52a1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Learn more at&nbsp;<a href=\"https:\/\/www.restek.com\/Force\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/Force<\/a><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Force Inert Biphenyl<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u53ef\u5206\u79bb\u5176\u4ed6\u82ef\u57fa\u548c C18 \u5316\u5b66\u76f8\u65e0\u6cd5\u5206\u79bb\u7684\u5316\u5408\u7269\u3002<strong>\u53ef\u4f7f\u7528\u7ec4\u6210\u7b80\u5355\u4e14\u4e0eMS\u517c\u5bb9\u7684\u6d41\u52a8\u76f8\uff0c\u5c24\u5176\u9002\u5408\u7528\u4e8e\u63d0\u9ad8\u4eb2\u6c34\u6027\u82b3\u9999\u7c7b\u5316\u5408\u7269\u7684\u4fdd\u7559\u6548\u679c<\/strong>\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Force Inert C18<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u8fd9\u6b3e\u901a\u7528\u578b\u7684 Restek Force Inert C18 \u662f\u4e00\u6b3e\u4f20\u7edf\u7684\u5355\u4f53\u5341\u516b\u70f7\u57fa\u7845\u70f7\u8272\u8c31\u67f1\uff0c\u9002\u7528\u4e8e\u4ece\u9178\u6027\u5230\u5f31\u78b1\u6027\u7684\u591a\u79cd\u5316\u5408\u7269\u5206\u6790\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u4e3a\u60a8\u7684\u5206\u6790\u5e26\u6765\u5353\u8d8a\u7684\u60f0\u6027<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f5c\u4e3a\u8272\u8c31\u5de5\u4f5c\u8005\uff0c\u6211\u4eec\u6df1\u77e5\u786e\u4fdd\u68c0\u6d4b\u6570\u636e\u7ed3\u679c\u53ef\u9760\u53ef\u4fe1\u7684\u91cd\u8981\u6027\u3002\u65e0\u8bba\u60a8\u5206\u6790\u7684\u662f\u519c\u836f\u3001\u9709\u83cc\u6bd2\u7d20\uff0c\u8fd8\u662f\u4efb\u4f55\u542b\u91d1\u5c5e\u654f\u611f\u5316\u5408\u7269\u7684\u6837\u54c1\uff0c\u8fd9\u4e9b\u5168\u65b0\u7684\u6db2\u76f8\u8272\u8c31\u67f1\u90fd\u80fd\u4e3a\u60a8\u7684\u5b9e\u9a8c\u5ba4\u63d0\u4f9b\u6240\u9700\u7684\u51c6\u786e\u5ea6\u3001\u901a\u91cf\u4e0e\u6027\u80fd\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u70b9\u51fb\u94fe\u63a5&nbsp;<a href=\"https:\/\/www.restek.com\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/contact-us<\/a>&nbsp;\u8054\u7cfb\u60a8\u5f53\u5730\u7684 Restek \u4ee3\u8868\uff0c\u8ba9\u60f0\u6027\u8272\u8c31\u6280\u672f\u52a9\u529b\u60a8\u624b\u5934\u7684\u5404\u7c7b\u5206\u6790\u5de5\u4f5c\u5427\u3002<\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A12-T\">                                \u8d27\u53f7\uff1a 9314A12-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Inert ARC-18, 2.7 \u00b5m, 100 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A12-T\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A12-T\">                                \u8d27\u53f7\uff1a 9309A12-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Inert Biphenyl, 2.7 \u00b5m, 100 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A12-T\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9629312-T\">                                \u8d27\u53f7\uff1a 9629312-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force Inert Biphenyl, 3 \u00b5m, 100 x 2.1 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9629312-T\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31971\">                                \u8d27\u53f7\uff1a 31971                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LC Multiresidue Pesticide Standards Kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31971\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34121\">                                \u8d27\u53f7\uff1a 34121                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Aflatoxins (B1, B2, G1, G2) Standard, 10 \u00b5g\/mL, Acetonitrile, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34121\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34122\">                                \u8d27\u53f7\uff1a 34122                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ochratoxin A Standard, 10 \u03bcg\/mL, Acetonitrile, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34122\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/32475\">                                \u8d27\u53f7\uff1a 32475                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LC Passivation Solution, Methylenediphosphonic Acid (Medronic Acid), 1760 \u00b5g\/mL, Methanol (HPLC grade)\/Water (50:50), 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/32475\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Restek \u5168\u65b0\u7684\u60f0\u6027\u6db2\u76f8\u67f1\u6280\u672f\u53ef\u5e2e\u52a9\u5b9e\u9a8c\u5ba4\u6539\u5584\u91d1\u5c5e\u654f\u611f\u5316\u5408\u7269\u7684\u5206\u6790\u3002\u8be5\u6db2\u76f8\u8272\u8c31\u67f1\u4e0d\u9508\u94a2\u8868\u5c42\u8986\u6709\u9ad8\u6027\u80fd\u60f0\u6027\u6d82\u5c42\uff0c\u80fd\u591f\u51cf\u5c11\u87af\u5408\u578b\u5206\u6790\u7269\u7684\u975e\u7279\u5f02\u6027\u5438\u9644\uff0c\u5b9e\u73b0\u9ad8\u7075\u654f\u68c0\u6d4b\u4e0e\u6d41\u7545\u7684\u8272\u8c31\u5cf0\u79ef\u5206\u3002\u642d\u914dRestek\u9ad8\u9009\u62e9\u6027\u56fa\u5b9a\u76f8\uff0c\u65b0\u578b\u60f0\u6027 \u6db2\u76f8\u8272\u8c31\u67f1 \u53ef\u5b8c\u7f8e\u9002\u7528\u4e8e\u6709\u673a\u78f7\u519c\u836f\u3001\u9709\u83cc\u6bd2\u7d20\u7b49\u91d1\u5c5e\u654f\u611f\u5316\u5408\u7269\u7684\u5206\u6790\u68c0\u6d4b\u3002 Restek \u60f0\u6027\u6db2\u76f8\u67f1\u56db\u5927\u5173\u952e\u4f18\u52bf\uff1a \u5353\u8d8a\u7684\u60f0\u6027\u5e26\u6765\u5353\u8d8a\u7684\u6027\u80fd \u6db2\u76f8\u8272\u8c31\u67f1\u5185\uff0c\u90e8\u5206\u5316\u5408\u7269\u6613\u4e0e\u91d1\u5c5e\u8868\u9762\u53d1\u751f\u975e\u7279\u5f02\u6027\u5438\u9644\uff08NSA\uff09\u6216\u975e\u7279\u5f02\u6027\u7ed3\u5408\uff08NSB\uff09\uff0c\u5bf9\u8be5\u7c7b\u5316\u5408\u7269\u7684\u5206\u6790\u957f\u671f\u4ee5\u6765\u5b58\u5728\u6280\u672f\u96be\u70b9\u3002\u6781\u6027\u5316\u5408\u7269\uff08\u591a\u4e3a\u9178\u6027\u7269\u8d28\uff09\u4f1a\u4e0e\u8272\u8c31\u67f1\u91d1\u5c5e\u5185\u58c1\u53d1\u751f\u76f8\u4e92\u4f5c\u7528\uff0c\u76f4\u89c2\u8868\u73b0\u4e3a\u5cf0\u5f62\u7578\u53d8\u3001\u68c0\u6d4b\u7075\u654f\u5ea6\u4e0b\u964d\uff0c\u6700\u7ec8\u5bfc\u81f4\u68c0\u6d4b\u6570\u636e\u53ef\u9760\u6027\u4e0d\u8db3\u3002\u672c\u54c1\u724c\u9ad8\u6027\u80fd\u60f0\u6027\u8272\u8c31\u67f1\u6280\u672f\u53ef\u6709\u6548\u6d88\u9664\u6d3b\u6027\u5206\u6790\u7269\u4e0e\u8272\u8c31\u67f1\u91d1\u5c5e\u786c\u4ef6\u4e4b\u95f4\u7684\u975e\u7279\u5f02\u6027\u5438\u9644\u4e0e\u975e\u7279\u5f02\u6027\u7ed3\u5408\uff0c\u4fdd\u969c\u5206\u6790\u4eba\u5458\u68c0\u6d4b\u91d1\u5c5e\u654f\u611f\u7c7b\u5206\u6790\u7269\u65f6\u6240\u5f97\u6570\u636e\u5177\u5907\u66f4\u9ad8\u53ef\u4fe1\u5ea6\u3002 \u5c06\u60f0\u6027\u6db2\u76f8\u67f1\u4e0e\u60f0\u6027\u4fdd\u62a4\u67f1\u914d\u5408\u4f7f\u7528\uff0c\u6536\u83b7\u66f4\u591a\u4f18\u52bf Restek\u60f0\u6027\u4fdd\u62a4\u67f1\u63d0\u4f9b\u591a\u79cd\u56fa\u5b9a\u76f8\uff0c\u5728\u4e3a \u6db2\u76f8\u67f1\u63d0\u4f9b\u6700\u4f73\u4fdd\u62a4\u7684\u540c\u65f6\uff0c\u4e5f\u53ef\u51cf\u5c11\u87af\u5408\u6027\u5206\u6790\u7269\u7684\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3002\u72ec\u7acb\u5f0f\u4fdd\u62a4\u67f1\u53ef\u4e0eRestek\u6240\u6709\u7cfb\u5217\u6db2\u76f8\u67f1\u914d\u5408\u4f7f\u7528\uff0c\u5e76\u4e13\u95e8\u8bbe\u8ba1\u7528\u4e8e\u8865\u5145\u548c\u589e\u5f3a\u60f0\u6027\u67f1\u7684\u6027\u80fd\u3002Restek\u60f0\u6027\u4fdd\u62a4\u67f1\u63d0\u4f9b\u591a\u79cd\u56fa\u5b9a\u76f8\uff0c\u5728\u4e3a \u6db2\u76f8\u67f1\u63d0\u4f9b\u6700\u4f73\u4fdd\u62a4\u7684\u540c\u65f6\uff0c\u4e5f\u53ef\u51cf\u5c11\u87af\u5408\u6027\u5206\u6790\u7269\u7684\u975e\u7279\u5f02\u6027\u7ed3\u5408\u3002\u72ec\u7acb\u5f0f\u4fdd\u62a4\u67f1\u53ef\u4e0eRestek\u6240\u6709\u7cfb\u5217\u6db2\u76f8\u67f1\u914d\u5408\u4f7f\u7528\uff0c\u5e76\u4e13\u95e8\u8bbe\u8ba1\u7528\u4e8e\u8865\u5145\u548c\u589e\u5f3a\u60f0\u6027\u67f1\u7684\u6027\u80fd\u3002 \u4ea7\u54c1\u7ebf\u4e30\u5bcc\uff0c\u6ee1\u8db3\u60a8\u7684\u72ec\u7279\u9700\u6c42 Restek\u60f0\u6027\u6db2\u76f8\u67f1\u63d0\u4f9b\u591a\u79cd\u7c7b\u578b\uff0c\u4ee5\u9002\u5e94\u5e7f\u6cdb\u7684\u5e94\u7528\u4e0e\u68c0\u6d4b\u65b9\u6cd5\u3002Restek\u60f0\u6027\u67f1\u53ef\u63d0\u4f9b\u4ee5\u4e0b\u7c7b\u578b\uff1aRaptor Biphenyl\u3001Raptor C18\u3001Raptor ARC-18\u3001Force Biphenyl \u548c Force C18\u3002\u9488\u5bf9\u4ee5\u4e0b\u7279\u5b9a\u5e94\u7528\uff0c\u63a8\u8350\u4f7f\u7528\u76f8\u5e94\u8272\u8c31\u67f1\uff1a \u60f0\u6027 LC \u8272\u8c31\u67f1 \u5e94\u7528 Raptor Inert ARC-18 \u519c\u836f Raptor Inert Biphenyl \u9709\u83cc\u6bd2\u7d20 Force Inert C18 \u7532\u57fa\u4e19\u4e8c\u9178 Raptor Inert C18 \u517d\u836f \u519c\u836f \u519c\u836f\u591a\u7ec4\u5206\u7b5b\u67e5\u4f53\u7cfb\u7ec4\u5206\u79cd\u7c7b\u7e41\u591a\uff0c\u91c7\u7528\u60f0\u6027\u6db2\u76f8\u8272\u8c31\u67f1\u53ef\u663e\u8457\u63d0\u5347\u68c0\u6d4b\u6548\u679c\u3002\u78f7\u9178\u5316\u7c7b\u3001\u9178\u6027\u3001\u5f3a\u6781\u6027\u5316\u5408\u7269\u53ca\u53ef\u87af\u5408\u91d1\u5c5e\u7684\u7269\u8d28\uff08\u6709\u673a\u78f7\u519c\u836f\u7b49\uff09\u6613\u4e0e\u5206\u6790\u8272\u8c31\u67f1\u5185\u58c1\u91d1\u5c5e\u6d3b\u6027\u4f4d\u70b9\u53d1\u751f\u76f8\u4e92\u4f5c\u7528\u3002\u672c\u7814\u7a76\u5f00\u53d1\u7684\u65b0\u578b\u60f0\u6027\u6db2\u76f8\u8272\u8c31\u67f1\u53ef\u6709\u6548\u6d88\u9664\u8be5\u7c7b\u5438\u9644\u5e72\u6270\uff0c\u5168\u65b9\u4f4d\u63d0\u5347\u591a\u7ec4\u5206\u519c\u836f\u7684\u6574\u4f53\u5206\u6790\u6548\u80fd\u3002 \u8868 I\uff1a\u5728\u672c\u6b21\u519c\u836f\u5206\u6790\u4e2d\uff0cRestek \u5168\u65b0\u60f0\u6027\u67f1\u7684\u5cf0\u9762\u79ef\u548c\u5cf0\u9ad8\u8f83\u4e0d\u9508\u94a2\u67f1\u6700\u591a\u63d0\u5347 2 \u500d \u5316\u5408\u7269 \u5cf0\u9762\u79ef \u5cf0\u9ad8 \u4e0d\u9508\u94a2 \u60f0\u6027 \u9762\u79ef\u6bd4(\u60f0\u6027\/\u4e0d\u9508\u94a2) \u4e0d\u9508\u94a2&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2266,2278,2271,2274],"post-badge":[],"resource-type":[],"product-library":[2572,2571,2553],"resource-technique":[2365],"ppma_author":[5],"class_list":["post-102834","post","type-post","status-publish","format-standard","hentry","category-articles-ja","industries-application-clinical-ja","industries-application-pharmaceutical-biopharma-ja","industries-application-environmental-ja","industries-application-food-beverage-ja","product-library-lc-ms-supplies-ja","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-ms-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2266,"label":"\u81e8\u5e8a"},{"value":2278,"label":"\u533b\u85ac\u54c1\uff5c\u30d0\u30a4\u30aa\u533b\u85ac\u54c1"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"}],"product-library":[{"value":2572,"label":"LC-MS \u95a2\u9023\u90e8\u54c1"},{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2365,"label":"MS\/MS"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":5,"user_id":2,"is_guest":0,"slug":"patrick-gallagherrestek-com","display_name":"Patrick Gallagher","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Gallagher_Patrick_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Gallagher_Patrick_Profile.jpg"},"author_category":"1","first_name":"Patrick","last_name":"Gallagher","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/102834","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=102834"}],"version-history":[{"count":1,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/102834\/revisions"}],"predecessor-version":[{"id":102835,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/102834\/revisions\/102835"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=102834"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=102834"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=102834"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=102834"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=102834"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=102834"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=102834"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=102834"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=102834"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}