{"id":103482,"date":"2025-01-01T00:00:00","date_gmt":"2025-01-01T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=103482"},"modified":"2026-09-18T15:00:31","modified_gmt":"2026-09-18T15:00:31","slug":"hplc-stationary-phases-toxicology","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/blogs-zh\/hplc-stationary-phases-toxicology\/","title":{"rendered":"\u6bd2\u7406\u5b66\u5b9e\u9a8c\u5ba4\u6db2\u76f8\u8272\u8c31\u67f1\u7684\u9009\u62e9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6211\u4eec\u77e5\u9053\u6db2\u76f8\u8272\u8c31\u67f1\u6709\u591a\u79cd\u7c7b\u578b\uff0c\u6bcf\u79cd\u7c7b\u578b\u90fd\u6709\u81ea\u5df1\u7684\u4f18\u52bf\u548c\u52a3\u52bf\uff0c\u5177\u4f53\u9009\u62e9\u54ea\u79cd\u8272\u8c31\u67f1\u53d6\u51b3\u4e8e\u60a8\u7684\u5206\u6790\u9700\u6c42\u3002\u65b0\u65b9\u6cd5\u5efa\u7acb\u4e4b\u521d\u9700\u8981\u7814\u7a76\u4e0d\u540c\u7c7b\u578b\u56fa\u5b9a\u76f8\u7684\u7279\u5f81\uff0c\u7279\u522b\u662f\u542b\u6709\u5173\u952e\u5cf0\u5bf9\u65f6\uff0c\u56fa\u5b9a\u76f8\u7684\u9009\u62e9\u5c24\u5176\u5173\u952e\u3002\u6bd2\u7269\u5206\u6790\u5b9e\u9a8c\u5ba4\u7684\u5206\u6790\u7269\u901a\u5e38\u5305\u62ec\u6ee5\u7528\u836f\u7269\u3001\u6cbb\u7597\u836f\u7269\u3001\u975e\u5904\u65b9\u836f\u7269\u548c\u9152\u7cbe\u4ee3\u8c22\u7269\u3002\u5206\u6790\u7269\u7684\u6781\u6027\u548c\u7ed3\u6784\u5dee\u5f02\u4f1a\u5728\u5f88\u5927\u7a0b\u5ea6\u4e0a\u5f71\u54cd\u5b83\u4eec\u4e0e\u4e0d\u540c\u56fa\u5b9a\u76f8\u7684\u76f8\u4e92\u4f5c\u7528\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9057\u61be\u7684\u662f\uff0c\u6ca1\u6709&#8221;\u4e07\u80fd&#8221;\u56fa\u5b9a\u76f8\u53ef\u4ee5\u6709\u6548\u5730\u5206\u6790\u6bd2\u7406\u5b66\u6d89\u53ca\u7684\u6240\u6709\u5316\u5408\u7269\u3002\u5927\u591a\u6570\u60c5\u51b5\u4e0b\uff0c\u65b9\u6cd5\u5f00\u53d1\u4eba\u5458\u9700\u8981\u4f7f\u7528\u51e0\u79cd\u4e0d\u540c\u7684\u56fa\u5b9a\u76f8\u6765\u6ee1\u8db3\u5bf9\u4e0d\u540c\u5206\u6790\u7269\u7684\u5206\u6790\u9700\u6c42\u3002\u8981\u627e\u51fa\u9002\u5408\u7684\u8272\u8c31\u67f1\uff0c\u60a8\u53ef\u4ee5\u9010\u4e00\u5c1d\u8bd5\u6216\u8005\u7ee7\u7eed\u9605\u8bfb\uff0c\u672c\u6587\u4ecb\u7ecd\u4e86\u6bd2\u7269\u5206\u6790\u65b9\u6cd5\u5f00\u53d1\u4e2d\u5e94\u8be5\u5c1d\u8bd5\u7684\u56fa\u5b9a\u76f8\u7c7b\u578b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">C18 \u8272\u8c31\u67f1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5927\u591a\u6570\u65b9\u6cd5\u5f00\u53d1\u4eba\u5458\u5c06 C18 \u8272\u8c31\u67f1\u89c6\u4e3a\u53cd\u76f8\u8272\u8c31\u4e2d\u7684&#8221;\u901a\u7528&#8221;\u6216&#8221;\u9996\u9009&#8221;\u8272\u8c31\u67f1\u3002C18\u662f\u4e00\u79cd\u6210\u719f\u53ef\u9760\u7684\u9009\u62e9\uff0c\u975e\u5e38\u9002\u5408\u5206\u6790\u6bd2\u7406\u5b66\u4e2d\u5e38\u89c1\u7684\u5927\u91cf\/\u591a\u7c7b\u5206\u6790\u7269\u3002C18 \u56fa\u5b9a\u76f8\u901a\u8fc7\u758f\u6c34\u4f5c\u7528\u5b9e\u73b0\u5bf9\u5f85\u6d4b\u7269\u7684\u4fdd\u7559\uff0c\u6240\u4ee5\u5b83\u4eec\u5728\u5206\u6790\u5177\u6709\u4e0d\u540c\u6781\u6027\u7684\u5206\u6790\u7269\u65f6\u662f\u4e00\u4e2a\u4e0d\u9519\u7684\u9009\u62e9\uff0c\u4f46\u5b83\u4eec\u5bf9\u4e00\u4e9b\u82b3\u9999\u65cf\u5173\u952e\u5f02\u6784\u4f53\u7684\u9009\u62e9\u6027\u7a0d\u5dee\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u7136C18\u53ef\u4ee5\u5206\u6790\u4e00\u4e9b\u96be\u5206\u79bb\u7684\u5316\u5408\u7269\u3002\u7532\u57fa\u82ef\u4e19\u80fa\u548c\u82ef\u4e19\u80fa\u7684D\u578b\u548cL\u578b\u5f02\u6784\u4f53\u901a\u5e38\u9700\u8981\u624b\u6027\u8272\u8c31\u67f1\u624d\u80fd\u5b9e\u73b0\u5206\u79bb\uff0c\u624b\u6027\u67f1\u9664\u4e86\u6602\u8d35\u4ee5\u5916\u7528\u9014\u4e5f\u4e0d\u662f\u5f88\u5e7f\u6cdb\u3002\u5bf9\u4e8e\u4e0d\u60f3\u7528\u624b\u6027\u67f1\u7684\u5b9e\u9a8c\u5ba4\uff0c\u53ef\u4ee5\u6309\u7167\u7b80\u5355\u7684\u884d\u751f\u5316\u65b9\u6cd5\u5728\u6807\u51c6C18\u8272\u8c31\u67f1\u4e0a\u8fdb\u884c\u5206\u79bb\uff08\u56fe1\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5373\u4f7fC18\u65e0\u6cd5\u5206\u79bb\u6bd2\u7406\u5b66\u5206\u6790\u8303\u56f4\u5185\u7684\u6bcf\u79cd\u5f85\u6d4b\u7269\uff0c\u60a8\u7684\u67dc\u5b50\u4e2d\u4ecd\u7136\u5e94\u8be5\u6709\u4e00\u652fC18\u5907\u7528\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 1\u00a0\uff1aRaptor C18 \u5206\u6790\u5c3f\u6db2\u4e2d\u7684 D \u548c L \u578b\u5b89\u975e\u4ed6\u660e\uff08DNPA \u884d\u751f\uff09\uff0c\u4e24\u7ec4\u5bf9\u6620\u5f02\u6784\u4f53\u5747\u5728\u4e0d\u4f7f\u7528\u624b\u6027\u67f1\u7684\u60c5\u51b5\u4e0b\u8fbe\u5230\u57fa\u7ebf\u5206\u79bb<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0737.png\" alt=\"d &amp; l Amphetamines (DNPA Derivatives) in Urine by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0737<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for l-Methamphetamine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/537-46-2\/l-Methamphetamine\" target=\"_blank\" rel=\"noopener\">l-Methamphetamine*<\/a><\/td><td class=\"oth\">3.11<\/td><td class=\"oth\">400.3<\/td><td class=\"oth\">339.0<\/td><td class=\"oth\">323.8<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for d-Methamphetamine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/537-46-2\/d-Methamphetamine\" target=\"_blank\" rel=\"noopener\">d-Methamphetamine*<\/a><\/td><td class=\"oth\">3.38<\/td><td class=\"oth\">400.3<\/td><td class=\"oth\">339.0<\/td><td class=\"oth\">323.8<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\">l-Amphetamine*<\/td><td class=\"oth\">4.16<\/td><td class=\"oth\">386.1<\/td><td class=\"oth\">325.0<\/td><td class=\"oth\">308.0<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for d-Amphetamine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-64-9\/d-Amphetamine\" target=\"_blank\" rel=\"noopener\">d-Amphetamine*<\/a><\/td><td class=\"oth\">4.55<\/td><td class=\"oth\">386.1<\/td><td class=\"oth\">325.0<\/td><td class=\"oth\">308.0<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">*Analytes are DNPA derivatives.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A12\" rel=\"noopener\">cat.# 9304A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor C18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A0252\" rel=\"noopener\">cat.# 9304A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>35 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>500 ng\/mL in urine<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.1% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.1% Formic acid in methanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>5.00<\/td><td>0.5<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>5.01<\/td><td>0.5<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>5.50<\/td><td>0.5<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>5.51<\/td><td>0.5<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>7.00<\/td><td>0.5<\/td><td>40<\/td><td>60<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A 500 ng\/mL standard (d- and l-amphetamines and methamphetamines) was prepared in pooled urine. Fifty microliters of the standard was aliquoted into a microcentrifuge tube. Ten microliters of a working internal standard (20 \u00b5g\/mL (\u00b1)-amphetamine-D11 and (\u00b1)-methamphetamine-D11 in water) and 20 \u00b5L of 1M NaHCO<sub>3<\/sub> was added and vortexed at 3000 rpm for 10 seconds. After vortexing, 100 \u00b5L of 0.1% (w\/v) Marfey&#8217;s reagent (1-fluoro-2-4-dinitrophenyl-5-L-alanine amide) in acetone was added, vortexed, and heated at 45 \u00b0C for 1 hour. Samples were allowed to cool to room temperature before the addition of 40 \u00b5L of 1M HCl in water. The sample was then vortexed and evaporated to dryness under nitrogen at 45 \u00b0C. Samples were reconstituted in 1 mL of 40:60 water:methanol (v\/v) and filtered using Thomson SINGLE StEP standard filter vials cat.# 25893 prior to analysis.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Thomson SINGLE StEP standard filter vials cat.# 25893 were used to produce this chromatogram, but have since been discontinued. For assistance choosing a replacement for this application, contact Restek Technical Service or your local Restek representative.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A0252<\/li><li>9304A12<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>d-AMP<\/li><li>d-MAMP<\/li><li>l-AMP<\/li><li>l-MAMP<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0737.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4f18\u52bf\uff1a<\/strong>C18 \u662f\u4e00\u79cd\u591a\u529f\u80fd\u7684\u6210\u719f\u56fa\u5b9a\u76f8\uff0c\u53ef\u4ee5\u5206\u6790\u5927\u91cf\u5177\u6709\u4e0d\u540c\u6781\u6027\u7684\u5f85\u6d4b\u7269\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5f31\u70b9\uff1a<\/strong>C18 \u4e0d\u5177\u5907\u5b8c\u5168\u5206\u79bb\u836f\u7269\/\u6ee5\u7528\u836f\u7269\u4e2d\u8bb8\u591a\u5173\u952e\u5f02\u6784\u4f53\u7684\u80fd\u529b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Biphenyl \u8054\u82ef\u8272\u8c31\u67f1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u867d\u7136\u8054\u82ef\u56fa\u5b9a\u76f8\u4e0d\u5982C18\u5e94\u7528\u5e7f\uff0c\u4f46\u5b83\u7684\u786e\u5177\u6709\u81ea\u8eab\u7684\u4f18\u52bf\u3002\u5b83\u7684\u6700\u5927\u4f18\u52bf\u662f\u5bf9\u82b3\u9999\u65cf\u5316\u5408\u7269\u5177\u6709\u4e00\u5b9a\u7684\u7ed3\u6784\u8bc6\u522b\u80fd\u529b\uff0c\u8fd9\u4f7f\u5f97\u5b83\u7279\u522b\u64c5\u957f\u5206\u79bb\u5173\u952e\u7684\u5f02\u6784\u4f53\u3002\u8fd9\u79cd\u7279\u6027\u6765\u81ea\u8054\u82ef\u5b98\u80fd\u56e2\u4e0e\u5f85\u6d4b\u7269\u7684\u03c0\u7535\u5b50\u4e4b\u95f4\u7684\u03c0-\u03c0\u4f5c\u7528\u3002\u56e0\u7532\u9187\u7ed3\u6784\u4e2d\u4e0d\u542b\u03c0\u7535\u5b50\uff0c\u4e0d\u4f1a\u5e72\u6270\u5f85\u6d4b\u7269\u4e0e\u8054\u82ef\u5b98\u80fd\u56e2\u4e4b\u95f4\u7684\u03c0-\u03c0\u4f5c\u7528\uff0c\u56e0\u6b64\u5f53\u4f7f\u7528\u8054\u82ef\u67f1\u65f6\u5e94\u5f53\u9996\u9009\u7532\u9187\u4f5c\u4e3a\u6709\u673a\u76f8\uff0c\u6709\u52a9\u4e8e\u5b8c\u5168\u91ca\u653e\u8054\u82ef\u7684\u6f5c\u529b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8054\u82ef\u56fa\u5b9a\u76f8\u53ef\u4ee5\u5206\u79bb\u5728C18\u6216\u82ef\u57fa\u67f1\u4e0a\u5206\u79bb\u8f83\u5dee\u7684\u5316\u5408\u7269\uff0c\u5728\u67d0\u4e9b\u60c5\u51b5\u4e0b\u8054\u82ef\u56fa\u5b9a\u76f8\u7684\u589e\u5f3a\u9009\u62e9\u6027\u4e5f\u6709\u52a9\u4e8e\u6700\u5927\u9650\u5ea6\u5730\u51cf\u5c11\u57fa\u8d28\u5e72\u6270\uff08\u56fe2\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 2\u00a0\uff1a\u5c3f\u6db2\u4e2d 18 \u79cd\u6ee5\u7528\u836f\u7269\u7684 LC-MS\/MS \u5206\u6790\uff08Raptor Biphenyl \u8054\u82ef\u6838\u58f3\u67f1\uff09\uff0c\u5173\u952e\u5f02\u6784\u4f53\u53ca\u57fa\u8d28\u5e72\u6270\u4e4b\u95f4\u5b8c\u5168\u5206\u79bb<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0568.png\" alt=\"Pain Panel in Urine on Raptor Biphenyl (50 x 3.0 mm) by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0568<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor ion<\/th><th style=\"text-align: center;width: 75px\">Product ion 1<\/th><th style=\"text-align: center;width: 75px\">Product ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Morphine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-27-2\/Morphine\" target=\"_blank\" rel=\"noopener\">Morphine*<\/a><\/td><td class=\"oth\">1.34<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">152.3<\/td><td class=\"oth\">165.3<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxymorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-41-5\/Oxymorphone\" target=\"_blank\" rel=\"noopener\">Oxymorphone<\/a><\/td><td class=\"oth\">1.40<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">227.3<\/td><td class=\"oth\">198.2<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydromorphone*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/466-99-9\/Hydromorphone\" target=\"_blank\" rel=\"noopener\">Hydromorphone*<\/a><\/td><td class=\"oth\">1.52<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">185.3<\/td><td class=\"oth\">128.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amphetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/300-62-9\/Amphetamine\" target=\"_blank\" rel=\"noopener\">Amphetamine<\/a><\/td><td class=\"oth\">1.62<\/td><td class=\"oth\">136.0<\/td><td class=\"oth\">91.3<\/td><td class=\"oth\">119.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methamphetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/537-46-2\/Methamphetamine\" target=\"_blank\" rel=\"noopener\">Methamphetamine<\/a><\/td><td class=\"oth\">1.84<\/td><td class=\"oth\">150.0<\/td><td class=\"oth\">91.2<\/td><td class=\"oth\">119.3<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Codeine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-57-3\/Codeine\" target=\"_blank\" rel=\"noopener\">Codeine*<\/a><\/td><td class=\"oth\">1.91<\/td><td class=\"oth\">300.2<\/td><td class=\"oth\">165.4<\/td><td class=\"oth\">153.2<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxycodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-42-6\/Oxycodone\" target=\"_blank\" rel=\"noopener\">Oxycodone<\/a><\/td><td class=\"oth\">2.02<\/td><td class=\"oth\">316.1<\/td><td class=\"oth\">241.3<\/td><td class=\"oth\">256.4<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydrocodone*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-29-1\/Hydrocodone\" target=\"_blank\" rel=\"noopener\">Hydrocodone*<\/a><\/td><td class=\"oth\">2.06<\/td><td class=\"oth\">300.1<\/td><td class=\"oth\">199.3<\/td><td class=\"oth\">128.3<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norbuprenorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78715-23-8\/Norbuprenorphine\" target=\"_blank\" rel=\"noopener\">Norbuprenorphine<\/a><\/td><td class=\"oth\">2.59<\/td><td class=\"oth\">414.1<\/td><td class=\"oth\">83.4<\/td><td class=\"oth\">101.0<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor ion<\/th><th style=\"text-align: center;width: 75px\">Product ion 1<\/th><th style=\"text-align: center;width: 75px\">Product ion 2<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meprobamate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-53-4\/Meprobamate\" target=\"_blank\" rel=\"noopener\">Meprobamate<\/a><\/td><td class=\"oth\">2.61<\/td><td class=\"oth\">219.0<\/td><td class=\"oth\">158.4<\/td><td class=\"oth\">97.2<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/437-38-7\/Fentanyl\" target=\"_blank\" rel=\"noopener\">Fentanyl<\/a><\/td><td class=\"oth\">2.70<\/td><td class=\"oth\">337.2<\/td><td class=\"oth\">188.4<\/td><td class=\"oth\">105.2<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Buprenorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52485-79-7\/Buprenorphine\" target=\"_blank\" rel=\"noopener\">Buprenorphine<\/a><\/td><td class=\"oth\">2.70<\/td><td class=\"oth\">468.3<\/td><td class=\"oth\">396.4<\/td><td class=\"oth\">414.5<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flurazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17617-23-1\/Flurazepam\" target=\"_blank\" rel=\"noopener\">Flurazepam<\/a><\/td><td class=\"oth\">2.73<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">315.2<\/td><td class=\"oth\">288.3<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sufentanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56030-54-7\/Sufentanil\" target=\"_blank\" rel=\"noopener\">Sufentanil<\/a><\/td><td class=\"oth\">2.77<\/td><td class=\"oth\">387.2<\/td><td class=\"oth\">238.5<\/td><td class=\"oth\">111.3<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methadone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-99-3\/Methadone\" target=\"_blank\" rel=\"noopener\">Methadone<\/a><\/td><td class=\"oth\">2.86<\/td><td class=\"oth\">310.2<\/td><td class=\"oth\">265.3<\/td><td class=\"oth\">105.3<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carisoprodol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-44-4\/Carisoprodol\" target=\"_blank\" rel=\"noopener\">Carisoprodol<\/a><\/td><td class=\"oth\">2.87<\/td><td class=\"oth\">261.2<\/td><td class=\"oth\">176.3<\/td><td class=\"oth\">158.1<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lorazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/846-49-1\/Lorazepam\" target=\"_blank\" rel=\"noopener\">Lorazepam<\/a><\/td><td class=\"oth\">3.03<\/td><td class=\"oth\">321.0<\/td><td class=\"oth\">275.4<\/td><td class=\"oth\">303.1<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/439-14-5\/Diazepam\" target=\"_blank\" rel=\"noopener\">Diazepam<\/a><\/td><td class=\"oth\">3.31<\/td><td class=\"oth\">285.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">153.9<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">*An extracted ion chromatogram (XIC) of the isobars is presented in the inset.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A5E\" rel=\"noopener\">cat.# 9309A5E<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 3.0 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Urine:mobile phase A:mobile phase B (17:76:7)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10-100 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water + 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol + 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.6<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>1.50<\/td><td>0.6<\/td><td>55<\/td><td>45<\/td><\/tr><tr><td>2.50<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>3.70<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>3.71<\/td><td>0.6<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>5.00<\/td><td>0.6<\/td><td>90<\/td><td>10<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>AB SCIEX API 4000 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>TurboIonSpray<sup>&reg;<\/sup> <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>API LC-MS\/MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Lorazepam was prepared at 100 ng\/mL; all other analytes are 10 ng\/mL.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A5E<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>drug<\/li><li>drugs<\/li><li>drugs of abuse<\/li><li>illicit drugs<\/li><li>matrix<\/li><li>pain<\/li><li>pain control<\/li><li>pain drugs<\/li><li>pain management<\/li><li>pain management drugs<\/li><li>urine<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0568.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4f18\u52bf\uff1a<\/strong>\u8054\u82ef\u8272\u8c31\u67f1\u6bd4 C18 \u548c\u5176\u4ed6\u82ef\u57fa\u67f1\u5177\u6709\u66f4\u5f3a\u7684\u9009\u62e9\u6027\uff0c\u80fd\u591f\u5206\u79bb\u5173\u952e\u5f02\u6784\u4f53\u3001\u8f83\u5c11\u57fa\u8d28\u5e72\u6270\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5f31\u70b9\uff1a<\/strong>\u8054\u82ef\u4e0d\u50cf C18 \u90a3\u6837\u5e38\u7528\uff0c\u56e0\u6b64\u65b9\u6cd5\u5f00\u53d1\u8fc7\u7a0b\u4e2d\u53ef\u80fd\u9700\u8981\u8fdb\u884c\u66f4\u591a\u7684\u81ea\u884c\u4f18\u5316\u5de5\u4f5c\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FluoroPhenyl \u6c1f\u82ef\u57fa\u8272\u8c31\u67f1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u6765\u8bf4\uff0cC18\u548c\u8054\u82ef\u67f1\u7ec4\u5408\u5373\u53ef\u6210\u529f\u5206\u6790\u6bd2\u7406\u5b66\u68c0\u6d4b\u8303\u56f4\u5185\u7684\u5316\u5408\u7269\u3002\u5176\u4e2d\u4e00\u4e2a\u4f8b\u5916\u662f\u5927\u9ebb\u7d20\u5f02\u6784\u4f53\u7684\u5206\u6790\u3002\u786e\u5b9a\u5927\u9ebb\u4f7f\u7528\u60c5\u51b5\u7684\u5178\u578b\u6bd2\u7406\u5b66\u6d4b\u8bd5\u5305\u62ec\u5206\u6790\u5927\u9ebb\u4e2d\u7684\u4e3b\u8981\u7cbe\u795e\u6d3b\u6027\u6210\u5206\u03949-THC\u53ca\u5176\u4e24\u79cd\u4ee3\u8c22\u726911-OH-\u03949-THC\u548c\u03949-THC-COOH\u3002\u03948-THC\uff08\u03949-THC\u7684\u4e00\u79cd\u5f02\u6784\u4f53\uff09\u7684\u51fa\u73b0\uff0c\u4f7f\u5f97\u5b9e\u9a8c\u5ba4\u4e5f\u5fc5\u987b\u5c06\u8fd9\u79cd\u5316\u5408\u7269\u53ca\u5176\u4ee3\u8c22\u7269\u7eb3\u5165\u5176\u6d4b\u8bd5\u8303\u56f4\u3002\u8fd9\u4efd\u66f4\u65b0\u7684\u5316\u5408\u7269\u5217\u8868\u5305\u542b\u516d\u79cd\u5206\u6790\u7269\u3001\u4e09\u5bf9\u5f02\u6784\u4f53\uff0c\u9700\u8981\u5b8c\u5168\u5206\u79bb\u624d\u80fd\u51fa\u5177\u51c6\u786e\u62a5\u544a\u3002C18 \u548c\u8054\u82ef\u8272\u8c31\u67f1\u7684\u9009\u62e9\u6027\u4e0d\u8db3\u4ee5\u5145\u5206\u5206\u79bb\u4e09\u5bf9\u5f02\u6784\u4f53\uff0c\u4f46\u6c1f\u82ef\u57fa\u8272\u8c31\u67f1\u5bf9\u6b64\u5177\u6709\u5145\u5206\u7684\u9009\u62e9\u6027\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b63\u5982\u6211\u4eec\u4e4b\u524d\u6240\u8ba8\u8bba\u7684\uff0cC18\u8272\u8c31\u67f1\u901a\u8fc7\u758f\u6c34\u4f5c\u7528\u5b9e\u73b0\u5206\u79bb\uff0c\u8054\u82ef\u67f1\u7684\u4fdd\u7559\u539f\u7406\u4e3a\u03c0-\u03c0\u4f5c\u7528\u3002\u9664\u4e86\u8272\u6563\u529b\u3001\u5f62\u72b6\u9009\u62e9\u6027\u5916\uff0c\u6c1f\u82ef\u57fa\u67f1\u8fd8\u6709\u9633\u79bb\u5b50\u4ea4\u6362\u548c\u5076\u6781\u4f5c\u7528\u4e24\u79cd\u4fdd\u7559\u673a\u7406\u3002\u6b63\u662f\u8fd9\u79cd\u591a\u4fdd\u7559\u673a\u5236\u4f7f\u6c1f\u82ef\u57fa\u8272\u8c31\u67f1\u80fd\u591f\u5b9e\u73b0\u72ec\u7279\u7684\u5206\u79bb\u6548\u679c\u3002\u5bf9\u4e8e\u9700\u8981\u5206\u6790THC\u5f02\u6784\u4f53\u7684\u6bd2\u7406\u5b66\u5b9e\u9a8c\u5ba4\u6765\u8bf4\uff0c\u6c1f\u82ef\u57fa\u67f1\u662f\u8fd9\u4e00\u8270\u96be\u5206\u79bb\u7684\u5fc5\u9009\u8272\u8c31\u67f1\uff08\u56fe3\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 3\u00a0\uff1aRaptor FluoroPhenyl \u8272\u8c31\u67f1\u5206\u6790\u5168\u8840\u4e2d\u7684 \u03949-THC\u3001\u03948-THC \u53ca\u5176\u7f9f\u57fa\u548c\u7fa7\u57fa\u4ee3\u8c22\u7269\uff0c\u4e09\u5bf9\u5f02\u6784\u4f53\u5747\u5b9e\u73b0\u5b8c\u5168\u5206\u79bb<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0826.png\" alt=\"\u03949-THC; \u03948-THC; Hydroxy- and Carboxy- Metabolites in Whole Blood on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0826<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28646-40-4\/11-OH-\u03948-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03948-THC<\/a><\/td><td class=\"oth\">4.66<\/td><td class=\"oth\">50<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34675-49-5\/11-OH-\u03949-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03949-THC<\/a><\/td><td class=\"oth\">5.00<\/td><td class=\"oth\">50<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39690-06-7\/\u03948-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03948-THC-COOH<\/a><\/td><td class=\"oth\">5.04<\/td><td class=\"oth\">250<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56354-06-4\/\u03949-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03949-THC-COOH<\/a><\/td><td class=\"oth\">5.85<\/td><td class=\"oth\">250<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5957-75-5\/\u03948-THC\" target=\"_blank\" rel=\"noopener\">\u03948-THC<\/a><\/td><td class=\"oth\">10.88<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">11.26<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor FluoroPhenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9319A1E\" rel=\"noopener\">cat.# 9319A1E<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 3 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor FluoroPhenyl EXP guard column cartridge 5 mm, 3 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9319A0253\" rel=\"noopener\">cat.# 9319A0253<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>\u03948-Tetrahydrocannabinol (\u03948-THC) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34090\" rel=\"noopener\">cat.# 34090<\/a>)<\/td><\/tr><tr><td><\/td><td>\u03949-Tetrahydrocannabinol (\u03949-THC) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34067\" rel=\"noopener\">cat.# 34067<\/a>)<\/td><\/tr><tr><td><\/td><td>(\u00b1)11-nor-9-carboxy-\u0394-9-THC (\u03949-THC-COOH) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34068\" rel=\"noopener\">cat.# 34068<\/a>)<\/td><\/tr><tr><td><\/td><td>Other compounds obtained separately. <\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>40:60 Water:methanol, both with 0.1% formic acid (v\/v)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.50<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.60<\/td><td>0.8<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.00<\/td><td>0.8<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.10<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.00<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.10<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>16.00<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>390 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu 8045 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Blank blood was spiked across the calibration range. Five hundred microliters of sample was added to a glass test tube. Fifty microliters of internal standard was added to each sample and vortexed. Samples were extracted by LLE. Five hundred microliters of HPLC grade water was added to each tube and vortexed. One hundred microliters of 10% acetic acid was added to each tube and vortexed. Two-and-a-half milliliters of 80:20 hexanes:ethyl acetate was added to each tube, capped, and vortexed until visibly combined. Samples were centrifuged at 2800 rpm for 15 minutes or until the two layers had completely separated. The supernatant was transferred to a clean test tube. Samples were dried down under nitrogen. Samples were reconstituted in 100 \u03bcL of 40:60 water:methanol, both with 0.1% formic acid, and vortexed. Samples were transferred to 2 mL short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) with glass vial inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21776\" rel=\"noopener\">cat.# 21776<\/a>) and capped with short-cap, screw-thread closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24498\" rel=\"noopener\">cat.# 24498<\/a>).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>The column was stored in 100% acetonitrile when not in use. <\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>FluoroPhenyl<\/li><li>THC Isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0826.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4f18\u52bf\uff1a<\/strong>\u6c1f\u82ef\u57fa\u8272\u8c31\u67f1\u5177\u6709\u72ec\u7279\u7684\u9009\u62e9\u6027\uff0c\u53ef\u4ee5\u6ee1\u8db3\u6bd2\u7406\u5b66\u4e2dTHC\u5f02\u6784\u4f53\u7684\u5206\u79bb\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5f31\u70b9\uff1a<\/strong>\u6c1f\u82ef\u57fa\u53ef\u80fd\u9700\u8981\u6bd4C18\u548c\u8054\u82ef\u66f4\u957f\u65f6\u95f4\u7684\u5e73\u8861\u548c\u518d\u5e73\u8861\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">EtG\/EtS \u4e13\u7528\u8272\u8c31\u67f1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e59\u57fa\u8461\u7cd6\u82f7\u9178\uff08EtG\uff09\u548c\u786b\u9178\u4e59\u916f\uff08EtS\uff09\u4e00\u822c\u4f5c\u4e3a\u76d1\u6d4b\u9152\u7cbe\u4f7f\u7528\u7684\u751f\u7269\u6807\u5fd7\u7269\u3002EtG \u548c EtS \u4e00\u822c\u7528LC-MS\/MS \u5206\u6790\uff0c\u5206\u6790\u4e2d\u9762\u4e34\u7684\u4e3b\u8981\u95ee\u9898\u6709\u4e09\u4e2a\uff0c\u4e00\u662f\u76ee\u6807\u7269\u6781\u6027\u9ad8\u4fdd\u7559\u5dee\uff1b\u4e8c\u662f\u76ee\u6807\u7269\u4e0e\u57fa\u8d28\u5e72\u6270\u7269\u5bb9\u6613\u5171\u6d17\u8131\uff0c\u5bb9\u6613\u9047\u5230\u57fa\u8d28\u6291\u5236\u95ee\u9898\uff1b\u4e09\u662f\u8fd0\u884c\u65f6\u95f4\u957f\u3002Raptor EtG\/EtS \u8272\u8c31\u67f1\u662f Restek \u4e13\u95e8\u4e3a\u89e3\u51b3\u8fd9\u4e9b\u75db\u70b9\u800c\u5f00\u53d1\u7684\u72ec\u7279\u56fa\u5b9a\u76f8\u3002EtG\/EtS \u8272\u8c31\u67f1\u53ef\u4e3a\u4e24\u79cd\u5316\u5408\u7269\u63d0\u4f9b\u7a33\u5b9a\u3001\u4e00\u81f4\u7684\u4fdd\u7559\uff0c\u5e76\u4e0e\u57fa\u8d28\u5b8c\u5168\u5206\u79bb\uff0c\u907f\u514d\u57fa\u8d28\u5e72\u6270\uff08\u56fe4\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 4\uff1aRaptor EtG\/EtS \u8272\u8c31\u67f1\u4e0a\u5c3f\u6db2\u4e2d\u7684 EtG\/EtS\uff0c\u4e24\u79cd\u5206\u6790\u7269\u90fd\u5b9e\u73b0\u4e86\u5145\u5206\u4fdd\u7559\uff0c\u4e14\u4e0e\u57fa\u8d28\u5e72\u6270\u5206\u79bb\u826f\u597d<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0739.png\" alt=\"EtG\/EtS on Raptor EtG\/EtS: Updated Method Conditions (Mobile Phase and Gradient)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0739<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl-\u03b2-D-glucuronide-d5 (EtG-d5)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1135070-98-2\/Ethyl-\u03b2-D-glucuronide-d5\" target=\"_blank\" rel=\"noopener\">Ethyl-\u03b2-D-glucuronide-d5 (EtG-d5)<\/a><\/td><td class=\"oth\">1.21<\/td><td class=\"oth\">200<\/td><td class=\"oth\">226.2<\/td><td class=\"oth\">85.0<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl-\u03b2-D-glucuronide (EtG)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17685-04-0\/Ethyl-\u03b2-D-glucuronide\" target=\"_blank\" rel=\"noopener\">Ethyl-\u03b2-D-glucuronide (EtG)<\/a><\/td><td class=\"oth\">1.23<\/td><td class=\"oth\">500<\/td><td class=\"oth\">221.2<\/td><td class=\"oth\">75.1<\/td><td class=\"oth\">85.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl sulfate-d5 (EtS-d5)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1329611-05-3\/Ethyl sulfate-d5\" target=\"_blank\" rel=\"noopener\">Ethyl sulfate-d5 (EtS-d5)<\/a><\/td><td class=\"oth\">2.36<\/td><td class=\"oth\">50<\/td><td class=\"oth\">130.1<\/td><td class=\"oth\">98.0<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl sulfate (EtS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/64-67-5\/Ethyl sulfate\" target=\"_blank\" rel=\"noopener\">Ethyl sulfate (EtS)<\/a><\/td><td class=\"oth\">2.38<\/td><td class=\"oth\">500<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">80.0<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor EtG\/EtS  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9325A12\" rel=\"noopener\">cat.# 9325A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>UltraShield UHPLC precolumn filter, 0.2 \u03bcm frit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25809\" rel=\"noopener\">cat.# 25809<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>35 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>Ethyl-\u03b2-D-glucuronide-d5 (EtG-d5) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34102\" rel=\"noopener\">cat.# 34102<\/a>)<\/td><\/tr><tr><td><\/td><td>Ethyl-\u03b2-D-glucuronide (EtG) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34101\" rel=\"noopener\">cat.# 34101<\/a>)<\/td><\/tr><tr><td><\/td><td>Ethyl sulfate-d5 sodium salt (EtS-d5) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34104\" rel=\"noopener\">cat.# 34104<\/a>)<\/td><\/tr><tr><td><\/td><td>Ethyl sulfate sodium salt (EtS) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34103\" rel=\"noopener\">cat.# 34103<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>0.01% Formic acid in water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>500 ng\/mL (40x acetonitrile precipitation sample prep)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.01% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.1% Formic acid in acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>3.00<\/td><td>0.5<\/td><td>65<\/td><td>35<\/td><\/tr><tr><td>3.01<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>4.50<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A 500 ng\/mL standard was prepared in urine. A 50 \u03bcL aliquot was mixed with 10 \u03bcL of internal standard (20 \u03bcg\/mL EtG-d5 and 5 \u03bcg\/mL EtS-d5 in water) and 150 \u00b5L of acetonitrile by vortexing at 3000 rpm for 10 seconds and centrifuged at 4300 rpm for 10 minutes at 10 \u00b0C. After centrifugation, 100 \u00b5L of the supernatant was diluted with 900 \u00b5L (40x dilution) of 0.01% formic acid in water. The sample was then vortexed at 3000 rpm for 10 seconds and injected for LC-MS\/MS analysis.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34102<\/li><li>34101<\/li><li>34104<\/li><li>34103<\/li><li>25809<\/li><li>9325A12<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>EtG<\/li><li>EtS<\/li><li>Sensitivity<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0739.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4f18\u52bf\uff1a<\/strong>\u8be5\u8272\u8c31\u67f1\u5177\u6709\u72ec\u7279\u7684\u9009\u62e9\u6027\uff0c\u4e13\u95e8\u7528\u4e8e\u9152\u7cbe\u4ee3\u8c22\u7269\u5206\u6790\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5f31\u70b9\uff1a<\/strong>\u4e3a\u83b7\u5f97\u6700\u4f73\u7ed3\u679c\uff0c\u8be5\u8272\u8c31\u67f1\u9700\u8981\u4f7f\u7528\u57fa\u8d28\u8fdb\u884c\u8c03\u8282\u3002\u672c\u8272\u8c31\u67f1\u5177\u6709\u7279\u5b9a\u7528\u9014\uff0c\u4e0d\u9002\u7528\u4e8e\u5206\u6790\u5927\u91cf\u76ee\u6807\u5316\u5408\u7269\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7ed3\u675f\u8bed<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6bd2\u7406\u5b66\u5b9e\u9a8c\u5ba4\u9700\u8981\u5206\u6790\u7684\u5316\u5408\u7269\u4e00\u822c\u8303\u56f4\u5e7f\u6cdb\u3001\u66f4\u65b0\u8fc5\u901f\u4e14\u5176\u5316\u5b66\u6027\u8d28\u5dee\u5f02\u5de8\u5927\u3002\u8fd9\u4e9b\u5316\u5408\u7269\u4e2d\u7684\u5927\u591a\u6570\u53ef\u4ee5\u7528 C18 \u548c\u8054\u82ef\u67f1\u5b9e\u73b0\u6210\u529f\u5206\u6790\uff0c\u5b83\u4eec\u5177\u6709\u4e92\u8865\u7684\u9009\u62e9\u6027\u3002\u7136\u800c\uff0cTHC \u5f02\u6784\u4f53\u548c EtG\/EtS \u7b49\u5177\u6709\u6311\u6218\u6027\u7684\u5206\u79bb\u5c06\u9700\u8981\u65b9\u6cd5\u5f00\u53d1\u4eba\u5458\u4f7f\u7528\u5176\u5b83\u8272\u8c31\u67f1\uff0c\u5982 FluoroPhenyl\/\u6c1f\u82ef\u57fa\u6216 EtG\/EtS \u4e13\u7528\u67f1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u4e86\u66f4\u597d\u534f\u52a9\u65b9\u6cd5\u5f00\u53d1\u4eba\u5458\u5efa\u7acb\u76f8\u5e94\u5206\u6790\u65b9\u6cd5\uff0cRestek\u63d0\u4f9b\u8272\u8c31\u67f1\u8bd5\u7528\u670d\u52a1\uff0c\u5173\u4e8e\u65b9\u6cd5\u7684\u4efb\u4f55\u7ec6\u8282\u95ee\u9898\uff0c\u6b22\u8fce\u968f\u65f6\u8054\u7cfb Restek \u6280\u672f\u56e2\u961f\uff1a4000 815 005\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A12\">                                \u8d27\u53f7\uff1a 9304A12                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 2.7 \u00b5m, 100 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A12\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0252\">                                \u8d27\u53f7\uff1a 9304A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18 EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 2.1 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0252\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A5E\">                                \u8d27\u53f7\uff1a 9309A5E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl, 2.7 \u00b5m, 50 x 3.0 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A5E\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">                                \u8d27\u53f7\uff1a 9319A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl, 2.7 \u00b5m, 100 x 3.0 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A0253\">                                \u8d27\u53f7\uff1a 9319A0253                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 3.0 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A0253\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9325A12\">                                \u8d27\u53f7\uff1a 9325A12                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor EtG\/EtS, 2.7 \u00b5m, 100 x 2.1 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9325A12\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25809\">                                \u8d27\u53f7\uff1a 25809                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">UltraShield UHPLC PreColumn Filter, 0.2 \u00b5m Frit, ea.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25809\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">                                \u8d27\u53f7\uff1a 34090                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">delta 8-Tetrahydrocannabinol (Delta 8-THC) Standard, 1000 \u00b5g\/mL in P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">                                \u8d27\u53f7\uff1a 34067                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">delta 9-Tetrahydrocannabinol (Delta 9-THC) Standard, 1000 \u00b5g\/mL, P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">                                \u8d27\u53f7\uff1a 34068                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">(\u00b1)11-nor-9-carboxy-Delta-9-THC Standard, 100 \u00b5g\/mL, methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34102\">                                \u8d27\u53f7\uff1a 34102                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ethyl-beta-D-Glucuronide-d5 (EtG-d5) Standard, 1000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34102\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34101\">                                \u8d27\u53f7\uff1a 34101                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ethyl-beta-D-Glucuronide (EtG) Standard, 1000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34101\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34104\">                                \u8d27\u53f7\uff1a 34104                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ethyl Sulfate-d5 Sodium Salt (EtS-d5) Standard, 1000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34104\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34103\">                                \u8d27\u53f7\uff1a 34103                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ethyl Sulfate Sodium Salt (EtS) Standard, 1000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34103\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">                                \u8d27\u53f7\uff1a 21143                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap Vial with Grad Marking Spot, 9-425 Screw-Thread, 2 mL, 9 mm, 12 x 32 (vial only), Amber, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">                                \u8d27\u53f7\uff1a 21776                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Glass, Big Mouth w\/Bottom Spring, 250 \u00b5L, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">                                \u8d27\u53f7\uff1a 24498                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short Screw Cap, Polypropylene, Screw-Thread, PTFE\/Silicone\/PTFE Septa, Blue, Preassembled, 2.0 mL, 9 mm, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u6211\u4eec\u77e5\u9053\u6db2\u76f8\u8272\u8c31\u67f1\u6709\u591a\u79cd\u7c7b\u578b\uff0c\u6bcf\u79cd\u7c7b\u578b\u90fd\u6709\u81ea\u5df1\u7684\u4f18\u52bf\u548c\u52a3\u52bf\uff0c\u5177\u4f53\u9009\u62e9\u54ea\u79cd\u8272\u8c31\u67f1\u53d6\u51b3\u4e8e\u60a8\u7684\u5206\u6790\u9700\u6c42\u3002\u65b0\u65b9\u6cd5\u5efa\u7acb\u4e4b\u521d\u9700\u8981\u7814\u7a76\u4e0d\u540c\u7c7b\u578b\u56fa\u5b9a\u76f8\u7684\u7279\u5f81\uff0c\u7279\u522b\u662f\u542b\u6709\u5173\u952e\u5cf0\u5bf9\u65f6\uff0c\u56fa\u5b9a\u76f8\u7684\u9009\u62e9\u5c24\u5176\u5173\u952e\u3002\u6bd2\u7269\u5206\u6790\u5b9e\u9a8c\u5ba4\u7684\u5206\u6790\u7269\u901a\u5e38\u5305\u62ec\u6ee5\u7528\u836f\u7269\u3001\u6cbb\u7597\u836f\u7269\u3001\u975e\u5904\u65b9\u836f\u7269\u548c\u9152\u7cbe\u4ee3\u8c22\u7269\u3002\u5206\u6790\u7269\u7684\u6781\u6027\u548c\u7ed3\u6784\u5dee\u5f02\u4f1a\u5728\u5f88\u5927\u7a0b\u5ea6\u4e0a\u5f71\u54cd\u5b83\u4eec\u4e0e\u4e0d\u540c\u56fa\u5b9a\u76f8\u7684\u76f8\u4e92\u4f5c\u7528\u3002 \u9057\u61be\u7684\u662f\uff0c\u6ca1\u6709&#8221;\u4e07\u80fd&#8221;\u56fa\u5b9a\u76f8\u53ef\u4ee5\u6709\u6548\u5730\u5206\u6790\u6bd2\u7406\u5b66\u6d89\u53ca\u7684\u6240\u6709\u5316\u5408\u7269\u3002\u5927\u591a\u6570\u60c5\u51b5\u4e0b\uff0c\u65b9\u6cd5\u5f00\u53d1\u4eba\u5458\u9700\u8981\u4f7f\u7528\u51e0\u79cd\u4e0d\u540c\u7684\u56fa\u5b9a\u76f8\u6765\u6ee1\u8db3\u5bf9\u4e0d\u540c\u5206\u6790\u7269\u7684\u5206\u6790\u9700\u6c42\u3002\u8981\u627e\u51fa\u9002\u5408\u7684\u8272\u8c31\u67f1\uff0c\u60a8\u53ef\u4ee5\u9010\u4e00\u5c1d\u8bd5\u6216\u8005\u7ee7\u7eed\u9605\u8bfb\uff0c\u672c\u6587\u4ecb\u7ecd\u4e86\u6bd2\u7269\u5206\u6790\u65b9\u6cd5\u5f00\u53d1\u4e2d\u5e94\u8be5\u5c1d\u8bd5\u7684\u56fa\u5b9a\u76f8\u7c7b\u578b\u3002 C18 \u8272\u8c31\u67f1 \u5927\u591a\u6570\u65b9\u6cd5\u5f00\u53d1\u4eba\u5458\u5c06 C18 \u8272\u8c31\u67f1\u89c6\u4e3a\u53cd\u76f8\u8272\u8c31\u4e2d\u7684&#8221;\u901a\u7528&#8221;\u6216&#8221;\u9996\u9009&#8221;\u8272\u8c31\u67f1\u3002C18\u662f\u4e00\u79cd\u6210\u719f\u53ef\u9760\u7684\u9009\u62e9\uff0c\u975e\u5e38\u9002\u5408\u5206\u6790\u6bd2\u7406\u5b66\u4e2d\u5e38\u89c1\u7684\u5927\u91cf\/\u591a\u7c7b\u5206\u6790\u7269\u3002C18 \u56fa\u5b9a\u76f8\u901a\u8fc7\u758f\u6c34\u4f5c\u7528\u5b9e\u73b0\u5bf9\u5f85\u6d4b\u7269\u7684\u4fdd\u7559\uff0c\u6240\u4ee5\u5b83\u4eec\u5728\u5206\u6790\u5177\u6709\u4e0d\u540c\u6781\u6027\u7684\u5206\u6790\u7269\u65f6\u662f\u4e00\u4e2a\u4e0d\u9519\u7684\u9009\u62e9\uff0c\u4f46\u5b83\u4eec\u5bf9\u4e00\u4e9b\u82b3\u9999\u65cf\u5173\u952e\u5f02\u6784\u4f53\u7684\u9009\u62e9\u6027\u7a0d\u5dee\u3002 \u5f53\u7136C18\u53ef\u4ee5\u5206\u6790\u4e00\u4e9b\u96be\u5206\u79bb\u7684\u5316\u5408\u7269\u3002\u7532\u57fa\u82ef\u4e19\u80fa\u548c\u82ef\u4e19\u80fa\u7684D\u578b\u548cL\u578b\u5f02\u6784\u4f53\u901a\u5e38\u9700\u8981\u624b\u6027\u8272\u8c31\u67f1\u624d\u80fd\u5b9e\u73b0\u5206\u79bb\uff0c\u624b\u6027\u67f1\u9664\u4e86\u6602\u8d35\u4ee5\u5916\u7528\u9014\u4e5f\u4e0d\u662f\u5f88\u5e7f\u6cdb\u3002\u5bf9\u4e8e\u4e0d\u60f3\u7528\u624b\u6027\u67f1\u7684\u5b9e\u9a8c\u5ba4\uff0c\u53ef\u4ee5\u6309\u7167\u7b80\u5355\u7684\u884d\u751f\u5316\u65b9\u6cd5\u5728\u6807\u51c6C18\u8272\u8c31\u67f1\u4e0a\u8fdb\u884c\u5206\u79bb\uff08\u56fe1\uff09\u3002 \u5373\u4f7fC18\u65e0\u6cd5\u5206\u79bb\u6bd2\u7406\u5b66\u5206\u6790\u8303\u56f4\u5185\u7684\u6bcf\u79cd\u5f85\u6d4b\u7269\uff0c\u60a8\u7684\u67dc\u5b50\u4e2d\u4ecd\u7136\u5e94\u8be5\u6709\u4e00\u652fC18\u5907\u7528\u3002 \u4f18\u52bf\uff1aC18 \u662f\u4e00\u79cd\u591a\u529f\u80fd\u7684\u6210\u719f\u56fa\u5b9a\u76f8\uff0c\u53ef\u4ee5\u5206\u6790\u5927\u91cf\u5177\u6709\u4e0d\u540c\u6781\u6027\u7684\u5f85\u6d4b\u7269\u3002 \u5f31\u70b9\uff1aC18 \u4e0d\u5177\u5907\u5b8c\u5168\u5206\u79bb\u836f\u7269\/\u6ee5\u7528\u836f\u7269\u4e2d\u8bb8\u591a\u5173\u952e\u5f02\u6784\u4f53\u7684\u80fd\u529b\u3002 Biphenyl \u8054\u82ef\u8272\u8c31\u67f1 \u867d\u7136\u8054\u82ef\u56fa\u5b9a\u76f8\u4e0d\u5982C18\u5e94\u7528\u5e7f\uff0c\u4f46\u5b83\u7684\u786e\u5177\u6709\u81ea\u8eab\u7684\u4f18\u52bf\u3002\u5b83\u7684\u6700\u5927\u4f18\u52bf\u662f\u5bf9\u82b3\u9999\u65cf\u5316\u5408\u7269\u5177\u6709\u4e00\u5b9a\u7684\u7ed3\u6784\u8bc6\u522b\u80fd\u529b\uff0c\u8fd9\u4f7f\u5f97\u5b83\u7279\u522b\u64c5\u957f\u5206\u79bb\u5173\u952e\u7684\u5f02\u6784\u4f53\u3002\u8fd9\u79cd\u7279\u6027\u6765\u81ea\u8054\u82ef\u5b98\u80fd\u56e2\u4e0e\u5f85\u6d4b\u7269\u7684\u03c0\u7535\u5b50\u4e4b\u95f4\u7684\u03c0-\u03c0\u4f5c\u7528\u3002\u56e0\u7532\u9187\u7ed3\u6784\u4e2d\u4e0d\u542b\u03c0\u7535\u5b50\uff0c\u4e0d\u4f1a\u5e72\u6270\u5f85\u6d4b\u7269\u4e0e\u8054\u82ef\u5b98\u80fd\u56e2\u4e4b\u95f4\u7684\u03c0-\u03c0\u4f5c\u7528\uff0c\u56e0\u6b64\u5f53\u4f7f\u7528\u8054\u82ef\u67f1\u65f6\u5e94\u5f53\u9996\u9009\u7532\u9187\u4f5c\u4e3a\u6709\u673a\u76f8\uff0c\u6709\u52a9\u4e8e\u5b8c\u5168\u91ca\u653e\u8054\u82ef\u7684\u6f5c\u529b\u3002 \u8054\u82ef\u56fa\u5b9a\u76f8\u53ef\u4ee5\u5206\u79bb\u5728C18\u6216\u82ef\u57fa\u67f1\u4e0a\u5206\u79bb\u8f83\u5dee\u7684\u5316\u5408\u7269\uff0c\u5728\u67d0\u4e9b\u60c5\u51b5\u4e0b\u8054\u82ef\u56fa\u5b9a\u76f8\u7684\u589e\u5f3a\u9009\u62e9\u6027\u4e5f\u6709\u52a9\u4e8e\u6700\u5927\u9650\u5ea6\u5730\u51cf\u5c11\u57fa\u8d28\u5e72\u6270\uff08\u56fe2\uff09\u3002 \u4f18\u52bf\uff1a\u8054\u82ef\u8272\u8c31\u67f1\u6bd4 C18 \u548c\u5176\u4ed6\u82ef\u57fa\u67f1\u5177\u6709\u66f4\u5f3a\u7684\u9009\u62e9\u6027\uff0c\u80fd\u591f\u5206\u79bb\u5173\u952e\u5f02\u6784\u4f53\u3001\u8f83\u5c11\u57fa\u8d28\u5e72\u6270\u3002 \u5f31\u70b9\uff1a\u8054\u82ef\u4e0d\u50cf C18 \u90a3\u6837\u5e38\u7528\uff0c\u56e0\u6b64\u65b9\u6cd5\u5f00\u53d1\u8fc7\u7a0b\u4e2d\u53ef\u80fd\u9700\u8981\u8fdb\u884c\u66f4\u591a\u7684\u81ea\u884c\u4f18\u5316\u5de5\u4f5c\u3002 FluoroPhenyl \u6c1f\u82ef\u57fa\u8272\u8c31\u67f1 \u4e00\u822c\u6765\u8bf4\uff0cC18\u548c\u8054\u82ef\u67f1\u7ec4\u5408\u5373\u53ef\u6210\u529f\u5206\u6790\u6bd2\u7406\u5b66\u68c0\u6d4b\u8303\u56f4\u5185\u7684\u5316\u5408\u7269\u3002\u5176\u4e2d\u4e00\u4e2a\u4f8b\u5916\u662f\u5927\u9ebb\u7d20\u5f02\u6784\u4f53\u7684\u5206\u6790\u3002\u786e\u5b9a\u5927\u9ebb\u4f7f\u7528\u60c5\u51b5\u7684\u5178\u578b\u6bd2\u7406\u5b66\u6d4b\u8bd5\u5305\u62ec\u5206\u6790\u5927\u9ebb\u4e2d\u7684\u4e3b\u8981\u7cbe\u795e\u6d3b\u6027\u6210\u5206\u03949-THC\u53ca\u5176\u4e24\u79cd\u4ee3\u8c22\u726911-OH-\u03949-THC\u548c\u03949-THC-COOH\u3002\u03948-THC\uff08\u03949-THC\u7684\u4e00\u79cd\u5f02\u6784\u4f53\uff09\u7684\u51fa\u73b0\uff0c\u4f7f\u5f97\u5b9e\u9a8c\u5ba4\u4e5f\u5fc5\u987b\u5c06\u8fd9\u79cd\u5316\u5408\u7269\u53ca\u5176\u4ee3\u8c22\u7269\u7eb3\u5165\u5176\u6d4b\u8bd5\u8303\u56f4\u3002\u8fd9\u4efd\u66f4\u65b0\u7684\u5316\u5408\u7269\u5217\u8868\u5305\u542b\u516d\u79cd\u5206\u6790\u7269\u3001\u4e09\u5bf9\u5f02\u6784\u4f53\uff0c\u9700\u8981\u5b8c\u5168\u5206\u79bb\u624d\u80fd\u51fa\u5177\u51c6\u786e\u62a5\u544a\u3002C18 \u548c\u8054\u82ef\u8272\u8c31\u67f1\u7684\u9009\u62e9\u6027\u4e0d\u8db3\u4ee5\u5145\u5206\u5206\u79bb\u4e09\u5bf9\u5f02\u6784\u4f53\uff0c\u4f46\u6c1f\u82ef\u57fa\u8272\u8c31\u67f1\u5bf9\u6b64\u5177\u6709\u5145\u5206\u7684\u9009\u62e9\u6027\u3002 \u6b63\u5982\u6211\u4eec\u4e4b\u524d\u6240\u8ba8\u8bba\u7684\uff0cC18\u8272\u8c31\u67f1\u901a\u8fc7\u758f\u6c34\u4f5c\u7528\u5b9e\u73b0\u5206\u79bb\uff0c\u8054\u82ef\u67f1\u7684\u4fdd\u7559\u539f\u7406\u4e3a\u03c0-\u03c0\u4f5c\u7528\u3002\u9664\u4e86\u8272\u6563\u529b\u3001\u5f62\u72b6\u9009\u62e9\u6027\u5916\uff0c\u6c1f\u82ef\u57fa\u67f1\u8fd8\u6709\u9633\u79bb\u5b50\u4ea4\u6362\u548c\u5076\u6781\u4f5c\u7528\u4e24\u79cd\u4fdd\u7559\u673a\u7406\u3002\u6b63\u662f\u8fd9\u79cd\u591a\u4fdd\u7559\u673a\u5236\u4f7f\u6c1f\u82ef\u57fa\u8272\u8c31\u67f1\u80fd\u591f\u5b9e\u73b0\u72ec\u7279\u7684\u5206\u79bb\u6548\u679c\u3002\u5bf9\u4e8e\u9700\u8981\u5206\u6790THC\u5f02\u6784\u4f53\u7684\u6bd2\u7406\u5b66\u5b9e\u9a8c\u5ba4\u6765\u8bf4\uff0c\u6c1f\u82ef\u57fa\u67f1\u662f\u8fd9\u4e00\u8270\u96be\u5206\u79bb\u7684\u5fc5\u9009\u8272\u8c31\u67f1\uff08\u56fe3\uff09\u3002 \u4f18\u52bf\uff1a\u6c1f\u82ef\u57fa\u8272\u8c31\u67f1\u5177\u6709\u72ec\u7279\u7684\u9009\u62e9\u6027\uff0c\u53ef\u4ee5\u6ee1\u8db3\u6bd2\u7406\u5b66\u4e2dTHC\u5f02\u6784\u4f53\u7684\u5206\u79bb\u3002 \u5f31\u70b9\uff1a\u6c1f\u82ef\u57fa\u53ef\u80fd\u9700\u8981\u6bd4C18\u548c\u8054\u82ef\u66f4\u957f\u65f6\u95f4\u7684\u5e73\u8861\u548c\u518d\u5e73\u8861\u3002 EtG\/EtS \u4e13\u7528\u8272\u8c31\u67f1 \u4e59\u57fa\u8461\u7cd6\u82f7\u9178\uff08EtG\uff09\u548c\u786b\u9178\u4e59\u916f\uff08EtS\uff09\u4e00\u822c\u4f5c\u4e3a\u76d1\u6d4b\u9152\u7cbe\u4f7f\u7528\u7684\u751f\u7269\u6807\u5fd7\u7269\u3002EtG \u548c EtS \u4e00\u822c\u7528LC-MS\/MS \u5206\u6790\uff0c\u5206\u6790\u4e2d\u9762\u4e34\u7684\u4e3b\u8981\u95ee\u9898\u6709\u4e09\u4e2a\uff0c\u4e00\u662f\u76ee\u6807\u7269\u6781\u6027\u9ad8\u4fdd\u7559\u5dee\uff1b\u4e8c\u662f\u76ee\u6807\u7269\u4e0e\u57fa\u8d28\u5e72\u6270\u7269\u5bb9\u6613\u5171\u6d17\u8131\uff0c\u5bb9\u6613\u9047\u5230\u57fa\u8d28\u6291\u5236\u95ee\u9898\uff1b\u4e09\u662f\u8fd0\u884c\u65f6\u95f4\u957f\u3002Raptor EtG\/EtS \u8272\u8c31\u67f1\u662f Restek \u4e13\u95e8\u4e3a\u89e3\u51b3\u8fd9\u4e9b\u75db\u70b9\u800c\u5f00\u53d1\u7684\u72ec\u7279\u56fa\u5b9a\u76f8\u3002EtG\/EtS \u8272\u8c31\u67f1\u53ef\u4e3a\u4e24\u79cd\u5316\u5408\u7269\u63d0\u4f9b\u7a33\u5b9a\u3001\u4e00\u81f4\u7684\u4fdd\u7559\uff0c\u5e76\u4e0e\u57fa\u8d28\u5b8c\u5168\u5206\u79bb\uff0c\u907f\u514d\u57fa\u8d28\u5e72\u6270\uff08\u56fe4\uff09\u3002 \u4f18\u52bf\uff1a\u8be5\u8272\u8c31\u67f1\u5177\u6709\u72ec\u7279\u7684\u9009\u62e9\u6027\uff0c\u4e13\u95e8\u7528\u4e8e\u9152\u7cbe\u4ee3\u8c22\u7269\u5206\u6790\u3002 \u5f31\u70b9\uff1a\u4e3a\u83b7\u5f97\u6700\u4f73\u7ed3\u679c\uff0c\u8be5\u8272\u8c31\u67f1\u9700\u8981\u4f7f\u7528\u57fa\u8d28\u8fdb\u884c\u8c03\u8282\u3002\u672c\u8272\u8c31\u67f1\u5177\u6709\u7279\u5b9a\u7528\u9014\uff0c\u4e0d\u9002\u7528\u4e8e\u5206\u6790\u5927\u91cf\u76ee\u6807\u5316\u5408\u7269\u3002 \u7ed3\u675f\u8bed \u6bd2\u7406\u5b66\u5b9e\u9a8c\u5ba4\u9700\u8981\u5206\u6790\u7684\u5316\u5408\u7269\u4e00\u822c\u8303\u56f4\u5e7f\u6cdb\u3001\u66f4\u65b0\u8fc5\u901f\u4e14\u5176\u5316\u5b66\u6027\u8d28\u5dee\u5f02\u5de8\u5927\u3002\u8fd9\u4e9b\u5316\u5408\u7269\u4e2d\u7684\u5927\u591a\u6570\u53ef\u4ee5\u7528 C18 \u548c\u8054\u82ef\u67f1\u5b9e\u73b0\u6210\u529f\u5206\u6790\uff0c\u5b83\u4eec\u5177\u6709\u4e92\u8865\u7684\u9009\u62e9\u6027\u3002\u7136\u800c\uff0cTHC \u5f02\u6784\u4f53\u548c EtG\/EtS \u7b49\u5177\u6709\u6311\u6218\u6027\u7684\u5206\u79bb\u5c06\u9700\u8981\u65b9\u6cd5\u5f00\u53d1\u4eba\u5458\u4f7f\u7528\u5176\u5b83\u8272\u8c31\u67f1\uff0c\u5982 FluoroPhenyl\/\u6c1f\u82ef\u57fa\u6216 EtG\/EtS \u4e13\u7528\u67f1\u3002&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":"{\"authors\":[432],\"author_categories\":{\"432\":\"1\"},\"fallback_author_user\":null,\"ppma_author_box_select\":\"none\",\"selected_authors\":[{\"id\":432,\"display_name\":\"Haley Berkland, MS\",\"is_guest\":0,\"category_id\":\"1\"}]}"},"categories":[790],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[432],"class_list":["post-103482","post","type-post","status-publish","format-standard","hentry","category-blogs-zh"],"acf":[],"taxonomy_info":{"category":[{"value":790,"label":"\u535a\u5ba2"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":790,"name":"\u535a\u5ba2","slug":"blogs-zh","term_group":0,"term_taxonomy_id":790,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":790,"category_count":457,"category_description":"","cat_name":"\u535a\u5ba2","category_nicename":"blogs-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/103482","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=103482"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/103482\/revisions"}],"predecessor-version":[{"id":103956,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/103482\/revisions\/103956"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=103482"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=103482"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=103482"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=103482"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=103482"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=103482"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=103482"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=103482"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=103482"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}