{"id":103502,"date":"2025-10-08T17:56:25","date_gmt":"2025-10-08T17:56:25","guid":{"rendered":"https:\/\/discover.restek.com\/?p=103502"},"modified":"2026-09-18T15:01:56","modified_gmt":"2026-09-18T15:01:56","slug":"epa-method-1634-for-6ppd-quinone-analysis","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/application-notes-zh\/epa-method-1634-for-6ppd-quinone-analysis\/","title":{"rendered":"\u4f9d\u7167EPA 1634\u8981\u6c42\uff0c\u4f18\u53166PPD-\u918c\u5206\u6790\u65b9\u6cd5"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u6458\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">EPA 1634 \u8349\u6848\u4e3b\u8981\u7528\u4e8e\u6c34\u6027\u57fa\u8d28\uff08\u4e3b\u8981\u662f\u96e8\u6c34\u548c\u5730\u8868\u6c34\uff09\u4e2d6PPD-\u918c\u7684\u6d4b\u5b9a\uff0c\u662f\u57fa\u4e8e\u6027\u80fd\u7684\u4e00\u4e2aLC-MS\/MS\u65b9\u6cd5\u3002\u6211\u4eec\u4f18\u5316\u4e86\u5206\u6790\u67f1\u548c\u8272\u8c31\u6761\u4ef6\uff0c\u5728\u6ee1\u8db3EPA 1634\u65b9\u6cd5\u89c4\u8303\u7684\u540c\u65f6\uff0c\u63d0\u9ad8\u5206\u6790\u6548\u7387\uff0c\u603b\u8fd0\u884c\u65f6\u95f4\u4ece10min\u7f29\u77ed\u52305.5min\uff0c\u4e3a\u5b9e\u9a8c\u5ba4\u63d0\u4f9b\u4e86\u4e00\u79cd\u9ad8\u6548\u3001\u53ef\u9760\u7684\u89e3\u51b3\u65b9\u6848\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5f15\u8a00<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">2023\u5e7412\u6708\u6839\u636e\u300a\u6e05\u6d01\u6c34\u6cd5\u6848\u300b\uff08CWA\uff09\uff0cEPA \u53d1\u5e03\u4e861634 \u8349\u6848\u65b9\u6cd5\uff0c\u4f7f\u7528\u6db2\u76f8\u8272\u8c31-\u4e32\u8054\u8d28\u8c31\u6cd5\uff08LC\/MS\/MS\uff09 \u6d4b\u5b9a\u6c34\u6027\u57fa\u8d28\u4e2d\u7684 6PPD-\u918c\uff0c\u4ee5\u5e94\u5bf96PPD-\u918c\u6e17\u5165\u5f84\u6d41\u6c34\u7684\u62c5\u5fe7\u30026PPD-\u918c\u662f\u8f6e\u80ce\u6297\u6c27\u5316\u52426-PPD\u7ecf\u81ed\u6c27\u6c27\u5316\u540e\u7684\u8f6c\u5316\u4ea7\u7269\uff0c\u5b83\u4f1a\u968f\u96e8\u6c34\u5f84\u6d41\u8fdb\u5165\u6c34\u751f\u751f\u6001\u7cfb\u7edf\uff0c\u4ece\u800c\u5bf9\u94f6\u9c91\u548c\u5176\u5b83\u5404\u79cd\u9c7c\u7c7b\u9020\u6210\u81f4\u547d\u4f24\u5bb3\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EPA 1634 \u8349\u6848\u65b9\u6cd5\u662f\u4e00\u79cd\u57fa\u4e8e\u6027\u80fd\u7684\u65b9\u6cd5\uff0c\u8fd9\u610f\u5473\u7740\u5982\u679c\u7ed3\u679c\u88ab\u8bc1\u660e\u4e0e\u65e2\u5b9a\u65b9\u6cd5\u89c4\u8303\u7b49\u6548\uff0c\u5219\u53ef\u4ee5\u5bf9\u5176\u8fdb\u884c\u66f4\u6539\u3002\u5728\u8fd9\u9879\u7814\u7a76\u4e2d\uff0c\u9664\u4f18\u5316\u4e86\u5206\u6790\u67f1\u548c LC-MS\/MS \u6761\u4ef6\u7f29\u77ed\u8fd0\u884c\u65f6\u95f4\u5916\uff0c\u5728\u6837\u54c1\u524d\u5904\u7406\u8fc7\u7a0b\u4e2d\u4f7f\u7528\u4e86\u6027\u80fd\u66f4\u9ad8\u7684 Resprep HLB SPE \u5c0f\u67f1\uff0c\u4ee5\u786e\u4fdd\u66f4\u597d\u7684\u63d0\u53d6\u6548\u679c\u3001\u8f83\u5c11\u57fa\u8d28\u5e72\u6270\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9e\u9a8c<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u6807\u51c6\u54c1\u6eb6\u6db2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e59\u8148\u4e3a\u6eb6\u5242\uff0c\u914d\u7f6e 7 \u4e2a\u4e0d\u540c\u6d53\u5ea6\uff08\u5177\u4f53\u89c1\u8868 I\uff09\u7684\u6807\u51c6\u54c1\u6eb6\u6db2\uff0c\u6839\u636e\u65b9\u6cd5\u9009\u62e9\u76f8\u5bf9\u6807\u51c6\u8bef\u5dee\uff08%RSE\uff09 \u6700\u5c0f\u7684\u62df\u5408\u66f2\u7ebf\u4f5c\u4e3a\u6821\u6b63\u66f2\u7ebf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868 I : \u6807\u51c6\u54c1\u6eb6\u6db2\u6d53\u5ea6<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr style=\"background-color: #008eaa;\">\n<td>\u00a0<\/td>\n<td style=\"color: #ffffff;\" colspan=\"7\"><strong>Calibration Standard Concentrations (ng\/mL)<\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #008eaa;\">\n<td style=\"color: #ffffff;\"><strong>Compound and Intermediate Standard Concentration<\/strong><\/td>\n<td style=\"color: #ffffff;\"><strong>C1<\/strong><\/td>\n<td style=\"color: #ffffff;\"><strong>C2<\/strong><\/td>\n<td style=\"color: #ffffff;\"><strong>C3<\/strong><\/td>\n<td style=\"color: #ffffff;\"><strong>C4<\/strong><\/td>\n<td style=\"color: #ffffff;\"><strong>C5<\/strong><\/td>\n<td style=\"color: #ffffff;\"><strong>C6<\/strong><\/td>\n<td style=\"color: #ffffff;\"><strong>C7<\/strong><\/td>\n<\/tr>\n<tr>\n<td>6PPD-quinone (20 ng\/mL)<\/td>\n<td>0.025<\/td>\n<td>0.050<\/td>\n<td>0.10<\/td>\n<td>0.50<\/td>\n<td>1.0<\/td>\n<td>5.0<\/td>\n<td>10.0<\/td>\n<\/tr>\n<tr>\n<td><sup>13<\/sup>C<sub>6<\/sub>-6PPD-quinone (20 ng\/mL)<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>D5-6PPD-quinone (20 ng\/mL)<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<td>1.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<h3 class=\"wp-block-heading\">QC \u6837\u54c1\u5236\u5907<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6839\u636eEPA 1634\u8349\u6848\u65b9\u6cd5\u7b2c7.2\u8282\uff0c\u7528\u4e8e\u7cbe\u5bc6\u5ea6\u3001\u51c6\u786e\u5ea6\u548c\u65b9\u6cd5\u68c0\u6d4b\u9650\u7684QC\u6837\u54c1\u7684\u5236\u5907\u65b9\u6cd5\uff1a\u5728\u805a\u4e19\u70ef\u74f6\u4e2d\u52a0\u5165250mL\u53bb\u79bb\u5b50\u6c34\u540e\u52a0\u516550\u03bcL\u63d0\u53d6\u548c\u975e\u63d0\u53d6\u5185\u6807\u7269\uff08EIS\/NIS\uff09\uff0c\u6807\u51c6\u54c1\u8d2d\u81ea\u5251\u6865\u540c\u4f4d\u7d20\u5b9e\u9a8c\u5ba4\uff08\u8d27\u53f7\u5206\u522b\u4e3a\uff1aCIL-ULM-12288-1.2\u3001CLM-12293-1.2 \u548c DLM-11616-1.2\uff09\u3002\u7528\u4e8e\u521d\u59cb\u7cbe\u5bc6\u5ea6\u548c\u56de\u6536\u7387\uff08IPR\uff09\u7684\u56db\u4e2a\u6837\u54c1\u52a0\u51656PPD-\u918c\u7684\u6d53\u5ea6\u4e3a40ng\/L\uff1b\u54116\u4efdMDL\u6837\u54c1\u4e2d\u52a0\u516550\u03bcL5\uff1a1\u7a00\u91ca\u7684\u5929\u7136\u6807\u51c6\u54c1\uff0c\u5f97\u5230\u9884\u63d0\u53d6\u6d53\u5ea6\u4e3a20ng\/mL\u7684\u6837\u54c1\u3002MDL\u6837\u54c1\u5728\u4e09\u5929\u5185\u5236\u5907\u3001\u63d0\u53d6\u548c\u5206\u6790\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u6c34\u6837<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u771f\u5b9e\u6c34\u6837\u53d6\u81ea\u5bbe\u5915\u6cd5\u5c3c\u4e9a\u5dde\u5dde\u7acb\u5927\u5b66 322-\u4e1c\u9ad8\u901f\u516c\u8def\u65c1\u5f84\u6d41\u6c34\uff0c\u88c5\u5728 250mL \u7425\u73c0\u73bb\u7483\u74f6\u4e2d\uff0c\u76d6\u5b50\u5e26\u805a\u56db\u6c1f\u4e59\u70ef\u5185\u886c\u3002\u6837\u54c1\u5728\u4f4e\u4e8e\u6216\u7b49\u4e8e6\u00b0C\u7684\u6e29\u5ea6\u4e0b\u50a8\u5b58\u3002\u6240\u6709\u6837\u672c\u5747\u5728\u91c7\u96c6\u540e14\u5929\u5185\u63d0\u53d6\u3002\u5728\u6837\u54c1\u63d0\u53d6\u524d\u52a0\u5165EIS\uff0c\u63d0\u53d6\u540e\u52a0\u5165NIS\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u6837\u54c1\u63d0\u53d6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728Dionex AutoTrace 280 PFAS \u7cfb\u7edf\u4e0a\u4f7f\u7528 Resprep HLB SPE \u5c0f\u67f1 \uff086 mL\uff0c60 \u03bcm\uff0c200mg HLB \uff0c\u8d27\u53f7 #28264\uff09 \u8fdb\u884c\u6837\u54c1\u63d0\u53d6\u3002\u5177\u4f53\u63d0\u53d6\u6b65\u9aa4\u5982\u56fe 1\u6240\u793a\uff0c\u5728\u4e09\u5929\u5185\u63d0\u53d6\u5b8c\u6837\u54c1\u3002\u63d0\u53d6\u540e\u5411\u6837\u54c1\u4e2d\u52a0\u516550 \u03bcL \u672a\u63d0\u53d6\u5185\u6807\uff08NIS\u6765\u81ea\u5251\u6865\u540c\u4f4d\u7d20\u5b9e\u9a8c\u5ba4\uff0c\u8d27\u53f7DLM-11616-1.2\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">\u56fe 1: \u6837\u54c1\u5236\u5907\u6b65\u9aa4 (\u6b65\u9aa41-6\u6536\u96c6\u7684\u6eb6\u5242\u8bf7\u6536\u96c6\u5230\u5e9f\u6db2\u4e2d)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image103502_ddd3ea-f0 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image103502_ddd3ea-f0\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"755\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-01-1024x755.jpg\" alt=\"\" class=\"kb-img wp-image-19486\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-01-1024x755.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-01-300x221.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-01-768x567.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-01-1536x1133.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u4eea\u5668\u65b9\u6cd5<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u4f7f\u7528Waters ACQUITY Premier LC\u548cXevo TQ Absolute\u4e09\u91cd\u56db\u6781\u6746\u8d28\u8c31\u3002\u8868II \u7ed9\u51fa\u4e86 EPA 1634 \u8349\u6848\u65b9\u6cd5\u7684\u539f\u59cb\u6761\u4ef6\uff0c\u672c\u7814\u7a76\u5f00\u53d1\u7684\u4f18\u5316\u8272\u8c31\u67f1\u548c\u6761\u4ef6\u5982\u8868III \u6240\u793a\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868 II: EPA 1634 \u65b9\u6cd5\u8349\u6848\u5efa\u8bae\u7684HPLC\u6761\u4ef6\uff08\u7b2c10.3.1\u8282\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>\u8272\u8c31\u67f1<\/td><td colspan=\"3\">C18 phase 4.6 x 100 mm, 3.5 \u00b5m<\/td><\/tr><tr><td>\u6d41\u52a8\u76f8 A<\/td><td colspan=\"3\">\u6c34\uff0c0.2%\u7532\u9178<\/td><\/tr><tr><td>\u6d41\u52a8\u76f8 B<\/td><td colspan=\"3\">\u4e59\u8148<\/td><\/tr><tr><td>\u67f1\u6e29<\/td><td colspan=\"3\">45 \u00b0C<\/td><\/tr><tr><td>\u8fdb\u6837\u91cf<\/td><td colspan=\"3\">20 \u00b5L<\/td><\/tr><tr><td>\u6d41\u901f<\/td><td colspan=\"3\">0.6 mL\/min<\/td><\/tr><tr><td>\u6700\u5927\u538b\u529b<\/td><td colspan=\"3\">7500 psi (517 bar)<\/td><\/tr><tr><td>\u68af\u5ea6<\/td><td>\u65f6\u95f4 (min)<\/td><td>%A<\/td><td>%B<\/td><\/tr><tr><td>&nbsp;<\/td><td>0<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>&nbsp;<\/td><td>1<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>&nbsp;<\/td><td>3<\/td><td>45<\/td><td>55<\/td><\/tr><tr><td>&nbsp;<\/td><td>6<\/td><td>1<\/td><td>99<\/td><\/tr><tr><td>&nbsp;<\/td><td>8<\/td><td>1<\/td><td>99<\/td><\/tr><tr><td>&nbsp;<\/td><td>8.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>&nbsp;<\/td><td>9<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>6PPD-\u918c\u9884\u671f\u6d17\u8131\u65f6\u95f4<\/td><td colspan=\"3\">7.53 min<\/td><\/tr><tr><td>\u603b\u8fd0\u884c\u65f6\u95f4<\/td><td colspan=\"3\">10.0 min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868 III : \u4f18\u5316\u540e LC \u65b9\u6cd5\u6761\u4ef6<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>\u8272\u8c31\u67f1<\/td><td colspan=\"3\">Raptor C18 50 x 2.1 mm, 2.7 \u00b5m (\u8d27\u53f7 9304A52)<\/td><\/tr><tr><td>\u4fdd\u62a4\u4f4f<\/td><td colspan=\"3\">Raptor C18 EXP\u67f1\u5957\uff0825808\uff09\u548c\u67f1\u82af 5 x 2.1 mm, 2.7 \u00b5m (\u8d27\u53f7 9304A0252)<\/td><\/tr><tr><td>\u6d41\u52a8\u76f8 A<\/td><td colspan=\"3\">\u6c34\uff0c0.1% \u7532\u9178<\/td><\/tr><tr><td>\u6d41\u52a8\u76f8 B<\/td><td colspan=\"3\">\u4e59\u8148\uff0c0.1% \u7532\u9178<\/td><\/tr><tr><td>\u6eb6\u5242<\/td><td colspan=\"3\">\u4e59\u8148<\/td><\/tr><tr><td>\u67f1\u6e29<\/td><td colspan=\"3\">40 \u00b0C<\/td><\/tr><tr><td>\u8fdb\u6837\u91cf<\/td><td colspan=\"3\">3 \u00b5L<\/td><\/tr><tr><td>\u6d41\u901f<\/td><td colspan=\"3\">0.5 mL\/min<\/td><\/tr><tr><td>\u6700\u5927\u538b\u529b<\/td><td colspan=\"3\">3200 psi (220 bar)<\/td><\/tr><tr><td>\u68af\u5ea6<\/td><td>\u65f6\u95f4 (min)<\/td><td>%A<\/td><td>%B<\/td><\/tr><tr><td>&nbsp;<\/td><td>0<\/td><td>70<\/td><td>30<\/td><\/tr><tr><td>&nbsp;<\/td><td>3<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>&nbsp;<\/td><td>4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>&nbsp;<\/td><td>4.01<\/td><td>70<\/td><td>30<\/td><\/tr><tr><td>&nbsp;<\/td><td>5.5<\/td><td>70<\/td><td>30<\/td><\/tr><tr><td>6PPD-\u918c\u9884\u671f\u6d17\u8131\u65f6\u95f4<\/td><td colspan=\"3\">1.93 min<\/td><\/tr><tr><td>\u603b\u8fd0\u884c\u65f6\u95f4<\/td><td colspan=\"3\">5.5 min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7ed3\u679c\u548c\u8ba8\u8bba<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">LC-MS\/MS\u65b9\u6cd5\u4f18\u5316\u53ca\u8272\u8c31\u6027\u80fd<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u7531\u4e8eEPA 1634 \u8349\u6848\u65b9\u6cd5\u662f\u57fa\u4e8e\u6027\u80fd\u7684\uff0c\u56e0\u6b64\u53ea\u8981\u4ecd\u7136\u6ee1\u8db3\u65b9\u6cd5\u6027\u80fd\u8981\u6c42\uff0c\u5b9e\u9a8c\u5ba4\u53ef\u4ee5\u4fee\u6539\u67d0\u4e9b\u65b9\u6cd5\u6761\u4ef6\u3002\u5728\u672c\u7814\u7a76\u4e2d\uff0c\u6211\u4eec\u4f18\u5316\u4e86\u51e0\u4e2a\u53c2\u6570\uff0c\u4ee5\u7f29\u77ed\u8fd0\u884c\u65f6\u95f4\uff0c\u63d0\u9ad8\u5b9e\u9a8c\u5ba4\u901a\u91cf\uff0c\u5e76\u521b\u5efa\u4e86\u4e00\u79cd\u53ef\u7528\u4e8eHPLC\u548cUHPLC\u5e73\u53f0\u7684\u65b9\u6cd5\u3002\u6211\u4eec\u7684\u6700\u7ec8\u4f18\u5316\u65b9\u6cd5\u5982\u56fe2\u6240\u793a\uff0c\u5c066PPD-\u918c\u7684\u4fdd\u7559\u65f6\u95f4\u4ece 7.53min\u7f29\u77ed\u5230 1.93min\uff0c\u5c06\u603b\u8fd0\u884c\u65f6\u95f4\u4ece 10 min\u7f29\u77ed\u5230 5.5 min\uff0c\u6700\u5927\u80cc\u538b\u7ea6\u4e3a220 bar\u3002\u4e0b\u9762\u8be6\u7ec6\u8ba8\u8bba\u4e86\u6bcf\u4e2a\u53c2\u6570\u5177\u4f53\u4f18\u5316\u8fc7\u7a0b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EPA 1634 \u8349\u6848\u65b9\u6cd5\u4f7f\u7528 C18 \u4f5c\u4e3a\u5206\u6790\u67f1\uff0c\u56e0\u6b64\u4f18\u5316\u65b9\u6cd5\u4e2d\u9009\u62e9\u7684\u8272\u8c31\u67f1\u4e3a Raptor C18\uff0cRaptor\u8272\u8c31\u67f1\u662f\u8868\u9762\u591a\u5b54\u9897\u7c92\uff08SPP\/\u6838\u58f3\u9897\u7c92\uff09\u8272\u8c31\u67f1\uff0c\u4e0e\u539f\u65b9\u6cd5\u4e2d3.5\u03bcm\u5168\u591a\u5b54\u9897\u7c92\u8272\u8c31\u67f1\u76f8\u6bd4\uff0c\u5b83\u5177\u6709\u6548\u7387\u9ad8\u3001\u8fd0\u884c\u65f6\u95f4\u77ed\u548c\u80cc\u538b\u4f4e\u7684\u7279\u70b9\u3002\u867d\u7136\u8349\u6848\u65b9\u6cd5\u4f7f\u7528\u7c92\u5f84\u4e3a 3.5\u03bcm\uff0c100 x 4.6 mm\uff0c\u4f46\u4e3a\u4e86\u63d0\u9ad8\u5206\u6790\u901f\u5ea6\uff0c\u4f18\u5316\u65b9\u6cd5\u65f6\u9009\u62e9\u7684\u8272\u8c31\u67f1\u4e3a2.7\u03bcm\uff0c50 x2.1 mm\u3002\u53e6\u5916\u5206\u6790\u67f1\u524d\u5b89\u88c5\u4e86Raptor C18 EXP\u4fdd\u62a4\u67f1\uff08\u8d27\u53f725808\u548c9304A0252\uff09\uff0c\u4ee5\u53bb\u9664\u9897\u7c92\u7269\u5ef6\u957f\u5206\u6790\u67f1\u4f7f\u7528\u5bff\u547d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8f83\u5c0f\u5185\u5f84ID\u5206\u6790\u67f1\u5141\u8bb8\u66f4\u5feb\u7684\u8fd0\u884c\u65f6\u95f4\uff0c\u5e76\u4e14\u7531\u4e8e\u4f7f\u7528\u4e86\u8f83\u4f4e\u7684\u6d41\u901f\u4ece\u800c\u964d\u4f4e\u4e86\u80cc\u538b\u548c\u6eb6\u5242\u6d88\u8017\u91cf\u3002\u5c3d\u7ba1\u4f7f\u7528\u7a84\u5185\u5f84\u8272\u8c31\u67f1\u7f29\u77ed\u4e86\u8fd0\u884c\u65f6\u95f4\uff0c\u4f46\u65e9\u671f\u6d17\u8131\u57fa\u8d28\u4e0e\u76ee\u6807\u7269\u5206\u79bb\u826f\u597d\uff0c\u6b64\u5916\u4f7f\u7528Resprep HLB SPE\u5c0f\u67f1\u8fdb\u884c\u6837\u54c1\u5236\u5907\uff0c\u53ef\u4ee5\u83b7\u5f97\u975e\u5e38\u5e72\u51c0\u7684\u6837\u54c1\u63d0\u53d6\u7269\uff0c\u4ece\u800c\u8fdb\u4e00\u6b65\u964d\u4f4e\u4e86\u57fa\u8d28\u5e72\u6270\u7684\u98ce\u9669\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56e0\u4e3a\u9009\u62e9\u4e86\u8f83\u5c0f\u7684\u67f1\u5c3a\u5bf8\uff0c\u8fdb\u6837\u91cf\u4ece20\u03bcL\u51cf\u5c0f\u5230\u4e863\u03bcL\u3002\u51cf\u5c11\u8fdb\u6837\u91cf\u6709\u51e0\u4e2a\u597d\u5904\uff1a\u51cf\u5c11\u4e86\u5f15\u5165\u7684\u57fa\u8d28\u91cf\u53ef\u4ee5\u6539\u5584\u8272\u8c31\u5206\u79bb\uff0c\u5ef6\u957f\u67f1\u5bff\u547d\uff0c\u51cf\u5c11\u57fa\u8d28\u6548\u5e94\uff0c\u5b83\u8fd8\u4fdd\u5b58\u4e86\u6837\u672c\uff0c\u4ee5\u9632\u9700\u8981\u91cd\u65b0\u5206\u6790\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u65b9\u6cd5\u4f18\u5316\u8fc7\u7a0b\u4e2d\uff0c\u6211\u4eec\u6bd4\u8f83\u4e86\u7532\u9187\u548c\u4e59\u8148\uff08\u4e24\u8005\u5747\u542b0.1%\u7532\u9178\uff09\u4f5c\u4e3a\u6709\u673a\u76f8\u65f6\u7684\u5206\u79bb\u6548\u679c\uff0c\u4e24\u79cd\u6709\u673a\u76f8\u7684\u7ed3\u679c\u90fd\u662f\u53ef\u4ee5\u63a5\u53d7\u7684\uff1b\u6211\u4eec\u6700\u7ec8\u9009\u62e9\u4e59\u8148\u4f5c\u4e3a\u6709\u673a\u76f8\u662f\u56e0\u4e3a\u907f\u514d\u6837\u54c1\u7a00\u91ca\u5242\u548c\u8d77\u59cb\u6d41\u52a8\u76f8\u4e0d\u5339\u914d\uff0c\u4ee5\u6539\u5584\u5cf0\u5f62\u5e76\u63d0\u9ad8\u7075\u654f\u5ea6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56e0\u4e3a\u4f7f\u7528\u8f83\u5c0f\u5185\u5f84\u8272\u8c31\u67f1\uff0c\u6d17\u8131\u68af\u5ea6\u4e5f\u4e0eEPA 1634\u8349\u6848\u65b9\u6cd5\u4e2d\u63cf\u8ff0\u7684\u6761\u4ef6\u4e0d\u540c\u3002\u4f18\u5316\u540e\u7684\u68af\u5ea6\u4e3a6PPD-\u918c\u63d0\u4f9b\u4e86\u5145\u5206\u7684\u4fdd\u7559\uff0c\u5e76\u907f\u514d\u4e86\u65e9\u671f\u6d17\u8131\u57fa\u8d28\u5bf9\u5f85\u6d4b\u7269\u7684\u5e72\u6270\u3002\u6d17\u81316PPD-\u918c\u540e\uff0c\u5728100%\u6709\u673a\u76f8B\u4e0b\u53c8\u8fd0\u884c\u4e863-4\u5206\u949f\uff0c\u4ee5\u51b2\u6d17\u67f1\u4e2d\u7684\u9ad8\u4fdd\u7559\u6c61\u67d3\u7269\uff0c\u7136\u540e\u6062\u590d\u5230\u8d77\u59cb\u6761\u4ef6\uff0c\u56e0\u6b64\u8272\u8c31\u67f1\u5728\u4e24\u6b21\u8fdb\u6837\u4e4b\u95f4\u8fdb\u884c\u4e86\u6709\u6548\u5730\u518d\u5e73\u8861\u3002\u6240\u5f00\u53d1\u7684\u65b9\u6cd5\u7684\u6700\u5927\u80cc\u538b220 bar\uff0c\u53ef\u7528\u4e8eHPLC\u548cUHPLC\u7cfb\u7edf\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">\u56fe 2: \u5728\u4f18\u5316\u7684 LC-MS\/MS \u6761\u4ef6\u4e0b\u5206\u6790\u5f84\u6d41\u6c34\u6837\u4e2d\u7684 6PPD-\u918c<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0600.png\" alt=\"6PPD-Quinone in Runoff Water on Raptor C18 by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0600<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6PPD-Quinone (6PPD-Q)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2754428-18-5\/6PPD-Quinone\" target=\"_blank\" rel=\"noopener\">6PPD-Quinone (6PPD-Q)<\/a><\/td><td class=\"oth\">1.93<\/td><td class=\"oth\">2.8<\/td><td class=\"oth\">299.22<\/td><td class=\"oth\">215.07<\/td><td class=\"oth\">241.08<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">6PPD-Quinone-D5 (6PPD-Q-D5)<\/td><td class=\"oth\">1.93<\/td><td class=\"oth\">1<\/td><td class=\"oth\">304.28<\/td><td class=\"oth\">220.08<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\">6PPD-Quinone-<sup>13<\/sup>C<sub>6<\/sub> (6PPD-Q-<sup>13<\/sup>C<sub>6<\/sub>)<\/td><td class=\"oth\">1.93<\/td><td class=\"oth\">1<\/td><td class=\"oth\">305.28<\/td><td class=\"oth\">221.19<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">The concentration listed is the final concentration following sample preparation.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A52\" rel=\"noopener\">cat.# 9304A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor C18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A0252\" rel=\"noopener\">cat.# 9304A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>3 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.1% Formic acid, water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.1% Formic acid, acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>70<\/td><td>30<\/td><\/tr><tr><td>3.00<\/td><td>0.5<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>4.00<\/td><td>0.5<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>4.01<\/td><td>0.5<\/td><td>70<\/td><td>30<\/td><\/tr><tr><td>5.50<\/td><td>0.5<\/td><td>70<\/td><td>30<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>220 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ-S<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY Premier<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Runoff water was collected from roadway 322-East, located in State College, PA, U.S. One-half milliliter of an extracted internal standard (EIS) solution (20 ng\/mL of 6PPD-Q-<sup>13<\/sup>C<sub>6<\/sub>) was added to 250 mL of sample. Resprep Polymeric SPE cartridges, HLB (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/28264\" rel=\"noopener\">cat.# 28264<\/a>), and a Thermo AutoTrace PFAS instrument were used for the following sample preparation procedure (steps 1-6 were diverted to waste):<br \/>1. Wash each cartridge with 5 mL of acetonitrile.<br \/>2. Wash each cartridge with 5 mL of reagent water. <br \/>3. Add 5 mL of reagent water to each cartridge. <br \/>4. Add the sample to the SPE column (250 mL) at a flow rate of 10-15 mL\/min until the entire sample has been loaded onto the column. <br \/>5. Rinse the sample bottle with 5 mL of 50:50 methanol:reagent water (v\/v) and then pour onto the column reservoir.<br \/>6. Once the rinse has completely passed through the cartridge, dry the cartridge under nitrogen for at least 5 minutes. <br \/>7. Rinse the sample bottles with 5 mL of acetonitrile and collect the SPE eluent using 15 mL polypropylene tubes. Samples should be pulled through using a low vacuum such that the solvent exits the cartridge in a dropwise fashion. <br \/>8. Repeat step 7 with a second 4-5 mL aliquot of acetonitrile. The total volume collected should be ~9-10 mL. <br \/>9. Add 0.5 mL of the non-extracted internal standard (NIS) solution (20 ng\/mL of 6PPD-Q-D5) to the sample extract and vortex.<br \/>10. Transfer an aliquot of the sample to a screw-thread polypropylene autosampler vial (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23243\" rel=\"noopener\">cat.# 23243<\/a>) and cap with a polypropylene screw-thread cap (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24486\" rel=\"noopener\">cat.# 24486<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A0252<\/li><li>9304A52<\/li><li>28264<\/li><li>23243<\/li><li>24486<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>6PPD-quinone<\/li><li>6ppd-q<\/li><li>epa 1634<\/li><li>raptor c18<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0600.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u7ebf\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u56fe3\u6240\u793a\uff0c\u4f18\u5316\u7684\u65b9\u6cd5\u57280.025-10 ng\/mL\u7684\u6821\u51c6\u8303\u56f4\u5185\u4ea7\u751f\u4e86\u826f\u597d\u7684\u7ebf\u6027\uff0cRSE=3.77%\uff0c\u5b8c\u5168\u5728&lt;20%\u7684\u65b9\u6cd5\u89c4\u8303\u8303\u56f4\u5185\u3002\u6b64\u5904\u8bc4\u4f30RSE\u800c\u4e0d\u662fr2\uff0c\u56e0\u4e3aEPA 1634\u8349\u6848\u65b9\u6cd5\u89c4\u5b9a\uff1a\u201c\u76f8\u5173\u7cfb\u6570r\u548c\u51b3\u5b9a\u7cfb\u6570r2\u4e0d\u518d\u88ab\u89c6\u4e3a\u7ebf\u6027\u7684\u9002\u5f53\u6307\u6807\uff0c\u4e0d\u5e94\u4e0e\u672c\u65b9\u6cd5\u7ed3\u5408\u4f7f\u7528[1]\u3002\u201d<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">\u56fe 3: \u6821\u51c6\u66f2\u7ebf\uff08\u4e8c\u6b21 1\/X \u62df\u5408\uff1b\u8fc7 0 \u70b9\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image103502_68e0a9-dd .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image103502_68e0a9-dd\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"600\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-03-1024x600.jpg\" alt=\"\" class=\"kb-img wp-image-19492\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-03-1024x600.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-03-300x176.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-03-768x450.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-03-1536x900.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evan4446-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">IPR<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u901a\u8fc7\u91cd\u590d\u8fdb\u6837\u5206\u6790\u56db\u4e2a40ng\/L\u7684\u52a0\u6807\u6837\u54c1\u6d4b\u5f97\u51c6\u786e\u6027\u548c\u7cbe\u786e\u6027\uff0c\u7ed3\u679c\u5982\u8868 IV \u6240\u793a\uff1a\u5e73\u5747\u56de\u6536\u7387\u4e3a95.00%\uff0cRSD\u4e3a4.00%\u3002EPA 1634 \u8349\u6848\u65b9\u6cd5\u89c4\u5b9a\u56de\u6536\u7387\u5fc5\u987b\u572870-130%\u8303\u56f4\u5185\uff0cRSD\u5fc5\u987b&lt;20%\uff0c\u56e0\u6b64\u8fd9\u4e9b\u7ed3\u679c\u5b8c\u5168\u5728\u65b9\u6cd5\u89c4\u683c\u8303\u56f4\u5185\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868 IV: IPR \u6570\u636e (\u6d53\u5ea6\u4e3a40 ng\/L\u7684\u52a0\u6807\u6837\u54c1 [n = 4])<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table style=\"border-color: #ced4d9;\">\n<tbody>\n<tr style=\"background-color: #008eaa; color: #ffffff;\">\n<td><strong>Sample #<\/strong><\/td>\n<td><strong>Recovery (ng\/L)<\/strong><\/td>\n<td><strong>Recovery (%)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>40.1<\/td>\n<td>100%<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>38.3<\/td>\n<td>95.80%<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>35.8<\/td>\n<td>89.50%<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>37.8<\/td>\n<td>94.50%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b9\u6cd5\u68c0\u6d4b\u9650\uff08MDL\uff09\u548c\u6700\u4f4e\u5b9a\u91cf\u6c34\u5e73\uff08ML\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3a\u4e86\u5efa\u7acb MDL \u548c ML\uff0c\u6839\u636e\u8349\u6848\u65b9\u6cd5\u5728 3 \u5929\u5185\u63d0\u53d6\u4e86 6 \u4e2a\u91cd\u590d\u6837\u54c1\u3002\u5c06\u52a0\u6807\u548c\u7a7a\u767d\u7ed3\u679c\u7684\u6807\u51c6\u504f\u5dee\u4e58\u4ee5t\u503c3.143\uff0c\u9009\u62e9\u52a0\u6807\u548c\u7a7a\u767d\u4e4b\u95f4\u7ed3\u679c\u7684\u8f83\u9ad8\u8005\u4f5c\u4e3aMDL\u3002\u5728\u7b2c20.2\u8282\u4e2d\uff0cEPA 1634 \u8349\u6848\u65b9\u6cd5\u89c4\u5b9a\u201cML\u53ef\u4ee5\u901a\u8fc7\u5c06MDL\uff08\u5408\u5e76\u6216\u975e\u5408\u5e76, \u89c6\u60c5\u51b5\u800c\u5b9a\uff09\u4e58\u4ee53.18\u5e76\u5c06\u7ed3\u679c\u56db\u820d\u4e94\u5165\u5230\u6700\u63a5\u8fd11\u30012\u62165 x 10n\u7684\u6570\u5b57\u6765\u83b7\u5f97\uff0c\u5176\u4e2dn\u4e3a\u96f6\u6216\u6574\u6570[1]\u3002\u201c\u5728\u6211\u4eec\u7684\u7814\u7a76\u4e2d\uff0cMDL\uff08\u975e\u5408\u5e76\uff09\u4e3a0.285 ng\/L\uff0cML\u4e3a1 ng\/L\uff08\u8868V\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868 V: \u53bb\u79bb\u5b50\u6c34\u4e2d 6-PPD-\u918c\u7684MDL\u548cML\u503c<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\" style=\"border-color: #ced4d9;\">\n<tbody>\n<tr style=\"background-color: #008eaa; color: #ffffff;\">\n<td><strong>MDL (ng\/L)<\/strong><\/td>\n<td><strong>ML (ng\/L)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0.285<\/td>\n<td>1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">EIS and NIS<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u8868VI\u6240\u793a\uff0cEIS\u7684\u5e73\u5747\u56de\u6536\u7387\u4e3a82.2%\uff0cRSD\u4e3a5.6%\u3002\u5bf9\u4e8eNIS\uff0c\u5e73\u5747\u56de\u6536\u7387\u4e3a117.8%\uff0cRSD\u4e3a1.9%\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868 VI: \u5185\u6807\u56de\u6536\u7387(n = 17)<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table style=\"border-color: #ced4d9;\">\n<tbody>\n<tr style=\"background-color: #008eaa; color: #ffffff;\">\n<td><strong>Compound<\/strong><\/td>\n<td><strong>Avg. % Recovery<\/strong><\/td>\n<td><strong>%RSD<\/strong><\/td>\n<\/tr>\n<tr>\n<td>EIS<\/td>\n<td>82.2%<\/td>\n<td>5.6%<\/td>\n<\/tr>\n<tr>\n<td>NIS<\/td>\n<td>117.8%<\/td>\n<td>1.9%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u5f84\u6d41\u6c34<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868VII \u4e2d\u663e\u793a\u7684\u6570\u636e\u8868\u660e\uff0c\u5f3a\u5316\u53bb\u79bb\u5b50\u6c34\u548c\u5f84\u6d41\u6c34\u7684\u56de\u6536\u7387\u5728\u65b9\u6cd5\u89c4\u5b9a\u8303\u56f4\u5185\uff0870-130%\uff09\u3002\u6b64\u5916\uff0c\u4e0e\u672a\u5f3a\u5316\u7684\u53bb\u79bb\u5b50\u6c34\u76f8\u6bd4\uff0c\u672a\u5f3a\u5316\u7684\u5f84\u6d41\u6c34\u5bf9 6PPD \u918c\u7684\u53cd\u5e94\u9ad8\u51fa\u7ea6 30%\uff0c\u8868\u660e 6PPD-\u918c\u5b58\u5728\u4e8e\u6536\u96c6\u57fa\u8d28\u6837\u54c1\u7684\u4f4d\u7f6e\uff0c\u4f46\u6c34\u5e73\u4f4e\u4e8e\u5b9a\u91cf\u9650\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868 VII: \u57fa\u8d28\u56de\u6536\u7387\uff0840 ng\/L\uff09<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table style=\"border-color: #ced4d9;\">\n<tbody>\n<tr style=\"background-color: #008eaa; color: #ffffff;\">\n<td><strong>Matrix<\/strong><\/td>\n<td><strong>%Recovery<\/strong><\/td>\n<\/tr>\n<tr>\n<td>DI water<\/td>\n<td>100.70%<\/td>\n<\/tr>\n<tr>\n<td>Runoff water<\/td>\n<td>95.50%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u7ed3\u8bba<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">EPA 1634\u8349\u6848\u65b9\u6cd5\u6982\u8ff0\u4e86\u4f7f\u7528LC\/MS\/MS \u5206\u6790\u6c34\u6027\u57fa\u8d28\uff08\u4e3b\u8981\u662f\u96e8\u6c34\u548c\u5730\u8868\u6c34\uff09\u4e2d\u76846PPD-\u918c\u3002\u7531\u4e8e\u5b83\u662f\u4e00\u79cd\u57fa\u4e8e\u6027\u80fd\u7684\u65b9\u6cd5\uff0c\u56e0\u6b64\u53ea\u8981\u6ee1\u8db3\u65b9\u6cd5\u8981\u6c42\uff0c\u5c31\u53ef\u4ee5\u8fdb\u884c\u66f4\u6539\u3002\u672c\u7814\u7a76\u7684\u91cd\u70b9\u662f\u5f00\u53d1\u4e00\u79cd\u4f18\u5316\u7684LC-MS\/MS \u65b9\u6cd5\uff0c\u4ee5\u52a0\u5feb\u5206\u6790\u901f\u5ea6\u5e76\u63d0\u9ad8\u5b9e\u9a8c\u5ba4\u7684\u6837\u54c1\u901a\u91cf\u3002\u6839\u636eEPA 1634\u8349\u6848\u65b9\u6cd5\u4f7f\u7528Dionex AutoTrace 280 PFAS \u7cfb\u7edf\u8fdb\u884c\u6837\u54c1\u5236\u5907\u548c\u8403\u53d6\uff0c\u5e76\u91c7\u7528\u4f18\u5316\u7684 LCMS\/MS\u65b9\u6cd5\uff0c\u8be5\u7814\u7a76\u83b7\u5f97\u4e86\u4ee5\u4e0b\u7ed3\u679c\u3002\u6821\u51c6\u8303\u56f4\u4e3a0.025\u201310 ng\/mL\uff0c%RSE\u4e3a3.77%\u3002EIS\uff0813C6-PPD-\u918c\uff09\u7684\u5e73\u5747\u56de\u6536\u7387\u4e3a 82.2% \uff08n = 17\uff09\uff0cRSD \u4e3a 5.6%\uff0c\u800c NIS\uff08D5-6-PPD-\u918c\uff09\u7684\u5e73\u5747\u56de\u6536\u7387\u4e3a 117.8%\uff0cRSD \u4e3a 1.9%\u3002\u65b9\u6cd5\u68c0\u6d4b\u9650(MDL)\u4e3a0.285ng\/L\uff0c\u76f8\u5f53\u4e8eML \u4e3a 1 ng\/L\u3002\u5f53IPR \u52a0\u6807\u6d53\u5ea6\u4e3a 40 ng\/L \u65f6\uff0c\u5e73\u5747\u56de\u6536\u7387\u4e3a 95.0%\uff0cRSD \u4e3a 4.0%\u3002\u52a0\u6807\u6d53\u5ea6\u4e3a 40ng\/L \u7684\u57fa\u8d28\u6837\u54c1\u7684\u56de\u6536\u7387\u4e3a 95.5%\uff0c\u800c\u53bb\u79bb\u5b50\u6c34\u52a0\u6807\u7684\u56de\u6536\u7387\u4e3a 100.7%\u3002\u6240\u6709\u7ed3\u679c\u5747\u8fbe\u5230\u6216\u8d85\u8fc7\u8be5\u65b9\u6cd5\u7684\u89c4\u683c\u3002\u9664\u4e0a\u8ff0\u7ed3\u679c\u5916\uff0c\u4f18\u5316\u7684HPLC \u65b9\u6cd5\u8fd8\u80fd\u591f\u5c06\u603b\u8fd0\u884c\u65f6\u95f4\u4ece 10 min\u7f29\u77ed\u81f3 5.5 min\uff0c\u4ece\u800c\u5c06 6PPD-\u918c\u7684\u6d17\u8131\u65f6\u95f4\u4ece 7.5min\u7f29\u77ed\u81f3 1.9min\u3002\u4f18\u5316\u540e\u7684\u65b9\u6cd5\u8fd8\u51cf\u5c11\u4e86\u8fdb\u6837\u4f53\u79ef\u5e76\u4fdd\u6301\u4e86\u4f4e\u80cc\u538b\uff0c\u56e0\u6b64\u53ef\u4ee5\u5728HPLC \u548c UHPLC \u4eea\u5668\u4e0a\u8fd0\u884c\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u81f4\u8c22<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f5c\u8005\u611f\u8c22 Grayson Ritch\u3001Diego L\u00f3pez \u548c Colton Myers \u5bf9\u8fd9\u9879\u5de5\u4f5c\u7684\u8d21\u732e\u3002<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. &nbsp; &nbsp;U.S. Environmental Protection Agency, Draft Method 1634, Determination of 6PPD-quinone in aqueous matrices using liquid chromatography with tandem mass spectrometry (LC MS\/MS), December 2023.&nbsp;<a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2025-02\/draft-method-1634_1-24-24_508.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/system\/files\/documents\/2025-02\/draft-method-1634_1-24-24_508.pdf<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0252\">                                \u8d27\u53f7\uff1a 9304A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18 EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 2.1 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0252\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A52\">                                \u8d27\u53f7\uff1a 9304A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 2.7 \u00b5m, 50 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A52\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28264\">                                \u8d27\u53f7\uff1a 28264                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep Polymeric SPE Cartridge, HLB, 6 mL\/200 mg, 60 \u00b5m, 30-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28264\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">                                \u8d27\u53f7\uff1a 25808                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Direct Connect Holder for EXP Guard Cartridges, Includes Fitting &amp; Ferrules<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u6458\u8981 EPA 1634 \u8349\u6848\u4e3b\u8981\u7528\u4e8e\u6c34\u6027\u57fa\u8d28\uff08\u4e3b\u8981\u662f\u96e8\u6c34\u548c\u5730\u8868\u6c34\uff09\u4e2d6PPD-\u918c\u7684\u6d4b\u5b9a\uff0c\u662f\u57fa\u4e8e\u6027\u80fd\u7684\u4e00\u4e2aLC-MS\/MS\u65b9\u6cd5\u3002\u6211\u4eec\u4f18\u5316\u4e86\u5206\u6790\u67f1\u548c\u8272\u8c31\u6761\u4ef6\uff0c\u5728\u6ee1\u8db3EPA 1634\u65b9\u6cd5\u89c4\u8303\u7684\u540c\u65f6\uff0c\u63d0\u9ad8\u5206\u6790\u6548\u7387\uff0c\u603b\u8fd0\u884c\u65f6\u95f4\u4ece10min\u7f29\u77ed\u52305.5min\uff0c\u4e3a\u5b9e\u9a8c\u5ba4\u63d0\u4f9b\u4e86\u4e00\u79cd\u9ad8\u6548\u3001\u53ef\u9760\u7684\u89e3\u51b3\u65b9\u6848\u3002 \u5f15\u8a00 2023\u5e7412\u6708\u6839\u636e\u300a\u6e05\u6d01\u6c34\u6cd5\u6848\u300b\uff08CWA\uff09\uff0cEPA \u53d1\u5e03\u4e861634 \u8349\u6848\u65b9\u6cd5\uff0c\u4f7f\u7528\u6db2\u76f8\u8272\u8c31-\u4e32\u8054\u8d28\u8c31\u6cd5\uff08LC\/MS\/MS\uff09 \u6d4b\u5b9a\u6c34\u6027\u57fa\u8d28\u4e2d\u7684 6PPD-\u918c\uff0c\u4ee5\u5e94\u5bf96PPD-\u918c\u6e17\u5165\u5f84\u6d41\u6c34\u7684\u62c5\u5fe7\u30026PPD-\u918c\u662f\u8f6e\u80ce\u6297\u6c27\u5316\u52426-PPD\u7ecf\u81ed\u6c27\u6c27\u5316\u540e\u7684\u8f6c\u5316\u4ea7\u7269\uff0c\u5b83\u4f1a\u968f\u96e8\u6c34\u5f84\u6d41\u8fdb\u5165\u6c34\u751f\u751f\u6001\u7cfb\u7edf\uff0c\u4ece\u800c\u5bf9\u94f6\u9c91\u548c\u5176\u5b83\u5404\u79cd\u9c7c\u7c7b\u9020\u6210\u81f4\u547d\u4f24\u5bb3\u3002 EPA 1634 \u8349\u6848\u65b9\u6cd5\u662f\u4e00\u79cd\u57fa\u4e8e\u6027\u80fd\u7684\u65b9\u6cd5\uff0c\u8fd9\u610f\u5473\u7740\u5982\u679c\u7ed3\u679c\u88ab\u8bc1\u660e\u4e0e\u65e2\u5b9a\u65b9\u6cd5\u89c4\u8303\u7b49\u6548\uff0c\u5219\u53ef\u4ee5\u5bf9\u5176\u8fdb\u884c\u66f4\u6539\u3002\u5728\u8fd9\u9879\u7814\u7a76\u4e2d\uff0c\u9664\u4f18\u5316\u4e86\u5206\u6790\u67f1\u548c LC-MS\/MS \u6761\u4ef6\u7f29\u77ed\u8fd0\u884c\u65f6\u95f4\u5916\uff0c\u5728\u6837\u54c1\u524d\u5904\u7406\u8fc7\u7a0b\u4e2d\u4f7f\u7528\u4e86\u6027\u80fd\u66f4\u9ad8\u7684 Resprep HLB SPE \u5c0f\u67f1\uff0c\u4ee5\u786e\u4fdd\u66f4\u597d\u7684\u63d0\u53d6\u6548\u679c\u3001\u8f83\u5c11\u57fa\u8d28\u5e72\u6270\u3002 \u5b9e\u9a8c \u6807\u51c6\u54c1\u6eb6\u6db2 \u4ee5\u4e59\u8148\u4e3a\u6eb6\u5242\uff0c\u914d\u7f6e 7 \u4e2a\u4e0d\u540c\u6d53\u5ea6\uff08\u5177\u4f53\u89c1\u8868 I\uff09\u7684\u6807\u51c6\u54c1\u6eb6\u6db2\uff0c\u6839\u636e\u65b9\u6cd5\u9009\u62e9\u76f8\u5bf9\u6807\u51c6\u8bef\u5dee\uff08%RSE\uff09 \u6700\u5c0f\u7684\u62df\u5408\u66f2\u7ebf\u4f5c\u4e3a\u6821\u6b63\u66f2\u7ebf\u3002 \u8868 I : \u6807\u51c6\u54c1\u6eb6\u6db2\u6d53\u5ea6 \u00a0 Calibration Standard Concentrations (ng\/mL) Compound and Intermediate Standard Concentration C1 C2 C3 C4 C5 C6 C7 6PPD-quinone (20 ng\/mL) 0.025 0.050 0.10 0.50&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":"{\"authors\":[456,447,432],\"author_categories\":{\"432\":\"1\",\"447\":\"1\",\"456\":\"1\"},\"fallback_author_user\":\"1\",\"ppma_author_box_select\":\"none\",\"selected_authors\":[{\"id\":456,\"display_name\":\"Alexis Shelow\",\"is_guest\":0,\"category_id\":\"1\"},{\"id\":447,\"display_name\":\"Jason Hoisington\",\"is_guest\":0,\"category_id\":\"1\"},{\"id\":432,\"display_name\":\"Haley Berkland, MS\",\"is_guest\":0,\"category_id\":\"1\"}]}"},"categories":[781],"tags":[],"industries-application":[2185],"post-badge":[],"resource-type":[],"product-library":[2427,2409],"resource-technique":[2361,2310],"ppma_author":[456,447,432],"class_list":["post-103502","post","type-post","status-publish","format-standard","hentry","category-application-notes-zh","industries-application-environmental-zh","product-library-lc-columns-zh","product-library-liquid-chromatography-products-zh","resource-technique-ms-ms-zh","resource-technique-liquid-chromatography-zh"],"acf":[],"taxonomy_info":{"category":[{"value":781,"label":"\u5e94\u7528\u7b14\u8bb0"}],"industries-application":[{"value":2185,"label":"\u73af\u5883"}],"product-library":[{"value":2427,"label":"LC\u8272\u8c31\u67f1"},{"value":2409,"label":"\u6db2\u76f8\u8272\u8c31\u76f8\u5173\u4ea7\u54c1"}],"resource-technique":[{"value":2361,"label":"MS\/MS"},{"value":2310,"label":"\u6db2\u76f8\u8272\u8c31"}]},"featured_image_src_large":false,"author_info":{"display_name":"DRCadmin","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":781,"name":"\u5e94\u7528\u7b14\u8bb0","slug":"application-notes-zh","term_group":0,"term_taxonomy_id":781,"taxonomy":"category","description":"","parent":0,"count":87,"filter":"raw","cat_ID":781,"category_count":87,"category_description":"","cat_name":"\u5e94\u7528\u7b14\u8bb0","category_nicename":"application-notes-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":456,"user_id":36,"is_guest":0,"slug":"alexis-shelow","display_name":"Alexis Shelow","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-shelow-alexis.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-shelow-alexis.jpg"},"author_category":"1","first_name":"Alexis","last_name":"Shelow","user_url":"https:\/\/www.linkedin.com\/in\/alexis-shelow-531b4513b\/","job_title":"SP Solutions Scientist (R&D)","description":"Alexis is a scientist in the sample preparation R&amp;D department. Her primary focus is SPE in the environmental sector. In her previous role at Restek as an LC manufacturing chemist, she developed skills related to synthesizing silica particles, bonding stationary phases, and optimizing procedural workflows. Alexis attended Delaware Valley University where she earned her BS in wildlife biology."},{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."},{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/103502","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=103502"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/103502\/revisions"}],"predecessor-version":[{"id":103960,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/103502\/revisions\/103960"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=103502"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=103502"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=103502"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=103502"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=103502"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=103502"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=103502"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=103502"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=103502"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}