{"id":104049,"date":"2020-10-21T00:00:00","date_gmt":"2020-10-21T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=104049"},"modified":"2026-09-20T09:54:32","modified_gmt":"2026-09-20T09:54:32","slug":"pfas-lc-column-anatomy-phase-dimensions-particle-type","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles-zh\/pfas-lc-column-anatomy-phase-dimensions-particle-type\/","title":{"rendered":"PFAS \u5206\u6790\u8272\u8c31\u67f1\u7684\u9009\u62e9\uff1a\u56fa\u5b9a\u76f8\u7c7b\u578b\u3001\u89c4\u683c\u4e0e\u9897\u7c92\u7c7b\u578b"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u5982\u679c\u60a8\u6240\u5728\u5b9e\u9a8c\u5ba4\u5f00\u5c55\u5168\u6c1f\u70f7\u57fa\u548c\u591a\u6c1f\u70f7\u57fa\u7269\u8d28\uff08PFAS\uff09\u7684\u6d4b\u8bd5\u5de5\u4f5c\uff0c\u90a3\u60a8\u4e00\u5b9a\u77e5\u9053\uff0c\u968f\u7740\u6211\u4eec\u5bf9\u8fd9\u7c7b\u201c\u6c38\u4e45\u6027\u5316\u5b66\u7269\u8d28\u201d\u7684\u666e\u904d\u6027\u3001\u6301\u4e45\u6027\u548c\u6f5c\u5728\u5065\u5eb7\u98ce\u9669\u7684\u66f4\u591a\u4e86\u89e3\uff0c\u4eba\u4eec\u5bf9\u8fd9\u7c7b\u5316\u5408\u7269\u7684\u5174\u8da3\u6b63\u5728\u4e0d\u65ad\u589e\u957f\u3002\u968f\u4e4b\u5bf9\u5feb\u901f\u3001\u51c6\u786e\u548c\u7cbe\u786e\u5206\u6790\u8fd9\u7c7b\u5316\u5408\u7269\u7684\u9700\u6c42\u4e5f\u5728\u6269\u5927\u3002\u8fd9\u4e9b\u9700\u6c42\u6b63\u63a8\u52a8\u66f4\u597d\u5206\u6790\u65b9\u6cd5\u7684\u51fa\u73b0\uff0c\u800c\u6db2\u76f8\u8272\u8c31\u67f1\u7684\u9009\u62e9\u662f\u6784\u5efa\u65b9\u6cd5\u7684\u57fa\u7840\u3002\u968f\u7740\u8d8a\u6765\u8d8a\u591a\u7684PFAS\u5316\u5408\u7269\u88ab\u5217\u5165\u7ba1\u63a7\u6e05\u5355\uff0c\u7279\u522b\u662f\u5bf9\u8d85\u77ed\u94fePFAS\u5316\u5408\u7269\u7684\u5173\u6ce8\uff0c\u65b0\u65b9\u6cd5\u7684\u5efa\u7acb\u53d8\u5f97\u5c24\u4e3a\u91cd\u8981\u3002\u5728\u8fd9\u91cc\uff0c\u6211\u4eec\u5c06\u4e0e\u5927\u5bb6\u63a2\u8ba8\u5982\u4f55\u6839\u636ePFAS\u76ee\u6807\u5f85\u6d4b\u53bb\u9009\u62e9\u5408\u9002\u7684\u6db2\u76f8\u8272\u8c31\u67f1\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u56fa\u5b9a\u76f8\u7c7b\u578b\u548c\u89c4\u683c\u7684\u9009\u62e9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u786e\u5b9a\u60a8\u5c06\u7814\u7a76\u7684PFAS\u5316\u5408\u7269\u8303\u56f4\uff0c\u5bf9\u4e8e\u8272\u8c31\u67f1\u56fa\u5b9a\u76f8\u7684\u9009\u62e9\u6700\u4e3a\u91cd\u8981\u3002\u9009\u62e9\u5bf9\u76ee\u6807\u5f85\u6d4b\u7269\u6709\u826f\u597d\u4fdd\u7559\u7684\u56fa\u5b9a\u76f8\u662f\u65b9\u6cd5\u5efa\u7acb\u7684\u7b2c\u4e00\u6b65\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u77ed\u94fe\u53ca\u4ee5\u4e0a PFAS<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u6d89\u53ca\u5230\u77ed\u94fePFAS\uff08C4-C6\uff09\u53ca\u4ee5\u4e0a\u7269\u8d28\u65f6\uff0c\u6211\u4eec\u5bf9\u4e0d\u540c\u7c7b\u578b\u8272\u8c31\u67f1\u5bf9\u6bd4\u540e\u53d1\u73b0\uff0cC18\u662f\u6700\u4f73\u9009\u62e9\u3002\u968f\u7740PFAS\u5206\u5b50\u4e0a\u7684\u70f7\u57fa\u94fe\u53d8\u957f\uff0c\u8fd9\u4e9b\u94fe\u4e0eC18\u914d\u4f53\u4e4b\u95f4\u7684\u76f8\u4e92\u4f5c\u7528\u589e\u52a0\uff0c\u4e3a\u4fdd\u7559\u548c\u5206\u79bb\u63d0\u4f9b\u4e86\u5f88\u597d\u7684\u673a\u5236\u3002\u56e0\u4e3a\u4fdd\u7559\u80fd\u529b\u8db3\u591f\u5f3a\uff0c\u56e0\u6b64\u53ef\u4ee5\u4f7f\u7528\u76f8\u5bf9\u8f83\u77ed\u7684\u7a84\u5185\u5f84\u8272\u8c31\u67f1\u5feb\u901f\u6709\u6548\u5730\u5206\u79bb\u76ee\u6807\u5316\u5408\u7269\u3002\u56fe1\u5c55\u793a\u7684\u662f\u7528RaptorC18\uff0c2.7 \u03bcm\uff0c50&#215;2.1mm\u8272\u8c31\u67f1\u5728\u4e0d\u52308\u5206\u949f\uff08\u603b\u5206\u6790\u65f6\u95f4\u4e3a10\u5206\u949f\uff09\u65f6\u95f4\u5185\u8f7b\u677e\u5206\u79bb\u76ee\u6807\u5316\u5408\u7269\uff0c\u800c\u4e14\u6ee1\u8db3EPA537.1\u996e\u7528\u6c34\u6d4b\u8bd5\u6807\u51c6\u7684\u8981\u6c42\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">\u56fe 1: Raptor C18\uff0850x 2.1mm \uff09\u8272\u8c31\u67f1\uff0c\u6839\u636e EPA 537.1 \u5206\u6790\u996e\u7528\u6c34\u4e2d PFAS\uff0c\u603b\u8fd0\u884c\u65f6\u95f4 10min<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0560.png\" alt=\"EPA Method 537.1 on Raptor C18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0560<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanesulfonic acid (PFBS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-73-5\/Perfluorobutanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanesulfonic acid (PFBS)<\/a><\/td><td class=\"oth\">2.06<\/td><td class=\"oth\">10<\/td><td class=\"oth\">298.8<\/td><td class=\"oth\">79.9<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2-<sup>13<\/sup>C<sub>2<\/sub>]hexanoic acid (<sup>13<\/sup>C<sub>2<\/sub>-PFHxA)<\/td><td class=\"oth\">3.03<\/td><td class=\"oth\">5<\/td><td class=\"oth\">314.9<\/td><td class=\"oth\">270.0<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanoic acid (PFHxA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-24-4\/Perfluorohexanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanoic acid (PFHxA)<\/a><\/td><td class=\"oth\">3.04<\/td><td class=\"oth\">5<\/td><td class=\"oth\">312.9<\/td><td class=\"oth\">268.7<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\">Tetrafluoro-2-heptafluoropropoxy-<sup>13<\/sup>C<sub>3<\/sub>-propanoic acid (<sup>13<\/sup>C<sub>3<\/sub>-HFPO-DA)<\/td><td class=\"oth\">3.36<\/td><td class=\"oth\">5<\/td><td class=\"oth\">286.8<\/td><td class=\"oth\">168.7<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexafluoropropylene oxide dimer acid (HFPO-DA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13252-13-6\/Hexafluoropropylene oxide dimer acid\" target=\"_blank\" rel=\"noopener\">Hexafluoropropylene oxide dimer acid (HFPO-DA)<\/a><\/td><td class=\"oth\">3.38<\/td><td class=\"oth\">5<\/td><td class=\"oth\">285.0<\/td><td class=\"oth\">168.9<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroheptanoic acid (PFHpA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-85-9\/Perfluoroheptanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroheptanoic acid (PFHpA)<\/a><\/td><td class=\"oth\">4.09<\/td><td class=\"oth\">5<\/td><td class=\"oth\">362.8<\/td><td class=\"oth\">318.8<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanesulfonic acid (PFHxS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/355-46-4\/Perfluorohexanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanesulfonic acid (PFHxS)<\/a><\/td><td class=\"oth\">4.22<\/td><td class=\"oth\">10<\/td><td class=\"oth\">398.8<\/td><td class=\"oth\">79.9<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/919005-14-4\/4,8-Dioxa-3H-perfluorononanoic acid\" target=\"_blank\" rel=\"noopener\">4,8-Dioxa-3H-perfluorononanoic acid (ADONA)<\/a><\/td><td class=\"oth\">4.24<\/td><td class=\"oth\">5<\/td><td class=\"oth\">376.9<\/td><td class=\"oth\">250.7<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\">Perfluoro-[1,2-<sup>13<\/sup>C<sub>2<\/sub>]octanoic acid (<sup>13<\/sup>C<sub>2<\/sub>-PFOA)<\/td><td class=\"oth\">4.88<\/td><td class=\"oth\">5<\/td><td class=\"oth\">415.0<\/td><td class=\"oth\">370.0<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">4.90<\/td><td class=\"oth\">5<\/td><td class=\"oth\">413.1<\/td><td class=\"oth\">368.9<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononanoic acid (PFNA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-95-1\/Perfluorononanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononanoic acid (PFNA)<\/a><\/td><td class=\"oth\">5.54<\/td><td class=\"oth\">5<\/td><td class=\"oth\">462.9<\/td><td class=\"oth\">418.9<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\">Perfluoro-1-[1,2,3,4-<sup>13<\/sup>C<sub>4<\/sub>]octanesulfonic acid (<sup>13<\/sup>C<sub>4<\/sub>-PFOS)<\/td><td class=\"oth\">5.57<\/td><td class=\"oth\">10<\/td><td class=\"oth\">503.0<\/td><td class=\"oth\">80.0<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanesulfonic acid (PFOS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1763-23-1\/Perfluorooctanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanesulfonic acid (PFOS)<\/a><\/td><td class=\"oth\">5.58<\/td><td class=\"oth\">10<\/td><td class=\"oth\">498.9<\/td><td class=\"oth\">80.0<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\">9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)<\/td><td class=\"oth\">5.88<\/td><td class=\"oth\">5<\/td><td class=\"oth\">530.8<\/td><td class=\"oth\">350.7<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2-<sup>13<\/sup>C<sub>2<\/sub>]decanoic acid (<sup>13<\/sup>C<sub>2<\/sub>-PFDA)<\/td><td class=\"oth\">6.08<\/td><td class=\"oth\">5<\/td><td class=\"oth\">514.9<\/td><td class=\"oth\">469.9<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecanoic acid (PFDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-76-2\/Perfluorodecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecanoic acid (PFDA)<\/a><\/td><td class=\"oth\">6.08<\/td><td class=\"oth\">5<\/td><td class=\"oth\">512.9<\/td><td class=\"oth\">469.0<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\">N-deuteriomethylperfluoro-1-octanesulfonamidoacetic acid (d3-NMeFOSAA)<\/td><td class=\"oth\">6.28<\/td><td class=\"oth\">10<\/td><td class=\"oth\">572.9<\/td><td class=\"oth\">418.8<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2355-31-9\/N-methyl perfluorooctanesulfonamidoacetic acid\" target=\"_blank\" rel=\"noopener\">N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)<\/a><\/td><td class=\"oth\">6.30<\/td><td class=\"oth\">10<\/td><td class=\"oth\">569.8<\/td><td class=\"oth\">418.8<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\">N-deuterioethylperfluoro-1-octanesulfonamidoacetic acid (d5-NEtFOSAA)<\/td><td class=\"oth\">6.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">588.9<\/td><td class=\"oth\">418.8<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2991-50-6\/N-ethyl perfluorooctanesulfonamidoacetic acid\" target=\"_blank\" rel=\"noopener\">N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">10<\/td><td class=\"oth\">583.8<\/td><td class=\"oth\">418.8<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroundecanoic acid (PFUnA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2058-94-8\/Perfluoroundecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroundecanoic acid (PFUnA)<\/a><\/td><td class=\"oth\">6.55<\/td><td class=\"oth\">5<\/td><td class=\"oth\">562.9<\/td><td class=\"oth\">518.8<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/763051-92-9\/11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid\" target=\"_blank\" rel=\"noopener\">11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)<\/a><\/td><td class=\"oth\">6.77<\/td><td class=\"oth\">5<\/td><td class=\"oth\">630.7<\/td><td class=\"oth\">451.0<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorododecanoic acid (PFDoA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-55-1\/Perfluorododecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorododecanoic acid (PFDoA)<\/a><\/td><td class=\"oth\">6.95<\/td><td class=\"oth\">5<\/td><td class=\"oth\">612.7<\/td><td class=\"oth\">568.9<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotridecanoic acid (PFTrDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72629-94-8\/Perfluorotridecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotridecanoic acid (PFTrDA)<\/a><\/td><td class=\"oth\">7.30<\/td><td class=\"oth\">5<\/td><td class=\"oth\">662.7<\/td><td class=\"oth\">618.8<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotetradecanoic acid (PFTA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/376-06-7\/Perfluorotetradecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotetradecanoic acid (PFTA)<\/a><\/td><td class=\"oth\">7.60<\/td><td class=\"oth\">5<\/td><td class=\"oth\">712.7<\/td><td class=\"oth\">668.7<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A52\" rel=\"noopener\">cat.# 9304A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>96:4 Methanol:water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>5-10 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>2 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 5 mM ammonium acetate <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>70<\/td><td>30<\/td><\/tr><tr><td>8.00<\/td><td>0.4<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>8.01<\/td><td>0.4<\/td><td>70<\/td><td>30<\/td><\/tr><tr><td>10.0<\/td><td>0.4<\/td><td>70<\/td><td>30<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Want even better performance when analyzing metal-sensitive compounds? Check out Inert LC columns at <a href=\"https:\/\/www.restek.com\/inert\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a>.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A52<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>ADONA<\/li><li>EPA537<\/li><li>GenX<\/li><li>HFPO-DA<\/li><li>PFAS<\/li><li>PFAS-library<\/li><li>PFOA<\/li><li>PFOS<\/li><li>Raptor<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0560.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u8d85\u77ed\u94fe PFAS<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53 C8 PFAS \u88ab\u7981\u7528\u540e\uff0c\u5176\u5b83\u8f83\u77ed\u94fe\u7684PFAS\u5316\u5408\u7269\u88ab\u4f5c\u4e3a\u66ff\u4ee3\u7269\u4f7f\u7528\u3002\u968f\u7740\u53d7\u5173\u6ce8PFAS\u6e05\u5355\u5316\u5408\u7269\u589e\u52a0\uff0cC4 PFAS\u751a\u81f3\u201c\u8d85\u77ed\u94fe\u201d\u7684(C2\u548cC3)\u6b63\u53d7\u5230\u8d8a\u6765\u8d8a\u591a\u7684\u5173\u6ce8\u3002\u968f\u7740\u78b3\u94fe\u7684\u7f29\u77ed\uff0cPFAS\u5316\u5408\u7269\u7684\u6781\u6027\u660e\u663e\u589e\u52a0\uff0c\u5bfc\u81f4\u5176\u5728\u4ee5\u758f\u6c34\u4f5c\u7528\u4e3a\u4e3b\u7684C18\u8272\u8c31\u67f1\u4e0a\u7684\u4fdd\u7559\u8d8a\u6765\u8d8a\u5f31\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u4e8e\u5168\u6c1f\u4e19\u9178\uff08PFPrA\uff09\u548c\u5168\u6c1f\u4e19\u78fa\u9178\uff08PFPrS\uff09\u7b49C3 PFAS\u5316\u5408\u7269\uff0c\u5f53\u9009\u62e9\u5408\u9002\u7684\u89c4\u683c\u65f6\uff0cC18\u8272\u8c31\u67f1\u4ecd\u7136\u53ef\u4ee5\u5de5\u4f5c\u3002\u5982\u56fe2\u6240\u793a\uff0c Raptor C18\uff0c100 x 3 mm\u663e\u793a\u4e86\u51fa\u8272\u7684\u6027\u80fd\uff0c\u53ef\u4ee5\u572811\u5206\u949f\u65f6\u95f4\u5185\u5feb\u901f\u5206\u6790\u5305\u542bC3\u957f\u5ea6\u7684PFAS\u7c7b\u5316\u5408\u7269\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">\u56fe 2\uff1aRaptor C18 \u8272\u8c31\u67f1\u4e5f\u53ef\u4ee5\u6709\u6548\u5206\u79bb\u77ed\u94fe PFAS\uff0c\u4f46\u5fc5\u987b\u589e\u52a0\u8272\u8c31\u67f1\u957f\u5ea6\u4ee5\u589e\u52a0\u8db3\u591f\u7684\u4fdd\u7559<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0555.png\" alt=\"Ultra-short Chain, Legacy, and Alternative PFAS on Raptor C18 in Reagent Water\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0555<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Perfluoropropanoic acid (PFPrA)<\/td><td class=\"oth\">2.74<\/td><td class=\"oth\">80<\/td><td class=\"oth\">162.9<\/td><td class=\"oth\">119.0<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanoic acid (PFBA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-22-4\/Perfluorobutanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanoic acid (PFBA)<\/a><\/td><td class=\"oth\">4.69<\/td><td class=\"oth\">80<\/td><td class=\"oth\">212.8<\/td><td class=\"oth\">169.0<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\">Perfluoropropanesulfonic acid (PFPrS)<\/td><td class=\"oth\">5.13<\/td><td class=\"oth\">80<\/td><td class=\"oth\">248.8<\/td><td class=\"oth\">79.6<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanesulfonic acid (PFBS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-73-5\/Perfluorobutanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanesulfonic acid (PFBS)<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">80<\/td><td class=\"oth\">298.8<\/td><td class=\"oth\">79.9<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2-<sup>13<\/sup>C<sub>2<\/sub>]hexanoic acid (<sup>13<\/sup>C<sub>2<\/sub>-PFHxA)<\/td><td class=\"oth\">6.75<\/td><td class=\"oth\">50<\/td><td class=\"oth\">314.9<\/td><td class=\"oth\">270.0<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexafluoropropylene oxide-dimer acid (HFPO-DA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13252-13-6\/Hexafluoropropylene oxide-dimer acid\" target=\"_blank\" rel=\"noopener\">Hexafluoropropylene oxide-dimer acid (HFPO-DA)<\/a><\/td><td class=\"oth\">6.92<\/td><td class=\"oth\">80<\/td><td class=\"oth\">285.0<\/td><td class=\"oth\">168.9<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/919005-14-4\/Ammonium 4,8-dioxa-3H-perfluorononanoate\" target=\"_blank\" rel=\"noopener\">Ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA)<\/a><\/td><td class=\"oth\">7.33<\/td><td class=\"oth\">80<\/td><td class=\"oth\">376.9<\/td><td class=\"oth\">250.7<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">7.70<\/td><td class=\"oth\">80<\/td><td class=\"oth\">413.1<\/td><td class=\"oth\">368.9<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\">Perfluoro-[1,2-<sup>13<\/sup>C<sub>2<\/sub>]octanoic acid (<sup>13<\/sup>C<sub>2<\/sub>-PFOA)<\/td><td class=\"oth\">7.70<\/td><td class=\"oth\">50<\/td><td class=\"oth\">415.0<\/td><td class=\"oth\">370.0<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanesulfonic acid (PFOS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1763-23-1\/Perfluorooctanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanesulfonic acid (PFOS)<\/a><\/td><td class=\"oth\">8.01<\/td><td class=\"oth\">80<\/td><td class=\"oth\">498.8<\/td><td class=\"oth\">80.0<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\">Perfluoro-[1,2,3,4-<sup>13<\/sup>C<sub>4<\/sub>]octanesulfonic acid (<sup>13<\/sup>C<sub>4<\/sub>-PFOS)<\/td><td class=\"oth\">8.01<\/td><td class=\"oth\">50<\/td><td class=\"oth\">503.0<\/td><td class=\"oth\">80.0<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 9-Chlorohexadecafluoro-3-oxanonane-1-sulfonate (9Cl-PF3ONS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/756426-58-1\/9-Chlorohexadecafluoro-3-oxanonane-1-sulfonate\" target=\"_blank\" rel=\"noopener\">9-Chlorohexadecafluoro-3-oxanonane-1-sulfonate (9Cl-PF3ONS)<\/a><\/td><td class=\"oth\">8.15<\/td><td class=\"oth\">80<\/td><td class=\"oth\">530.8<\/td><td class=\"oth\">350.7<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">11-Chloroeicosafluoro-3-oxanonane-1-sulfonate (11Cl-PF3OUdS)<\/td><td class=\"oth\">8.61<\/td><td class=\"oth\">80<\/td><td class=\"oth\">630.7<\/td><td class=\"oth\">451.0<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A1E\" rel=\"noopener\">cat.# 9304A1E<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 3 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>80  ppt<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 5 mM ammonium acetate <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.25<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>7.00<\/td><td>0.25<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>9.00<\/td><td>0.25<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>9.01<\/td><td>0.25<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>11.0<\/td><td>0.25<\/td><td>80<\/td><td>20<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>In a polypropylene vial, 250 \u00b5L of reagent water (fortified at 80 ppt) was mixed with 250 \u00b5L of 40:60 reagent water:methanol and 5 \u00b5L of internal standard solution (5 ng\/mL of <sup>13<\/sup>C<sub>2<\/sub>-PFHxA, <sup>13<\/sup>C<sub>2<\/sub>-PFOA, <sup>13<\/sup>C<sub>4<\/sub>-PFOS in methanol). The vial was capped with a polyethylene cap prior to analysis.  <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>A PFAS delay column (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/27854\" rel=\"noopener\">cat.# 27854<\/a>) was installed between the pump mixer and the injector.<br \/><br \/>Want even better performance when analyzing metal-sensitive compounds? Check out Inert LC columns at <a href=\"https:\/\/www.restek.com\/inert\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a>.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A1E<\/li><li>27854<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>11Cl-PF3OUdS<\/li><li>9Cl-PF3ONS<\/li><li>ADONA<\/li><li>HFPO-DA<\/li><li>PFAS<\/li><li>PFAS-library<\/li><li>PFPrA<\/li><li>PFPrS<\/li><li>Ultrashort Chain<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0555.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u5982\u679c\u6700\u7ec8C2 PFAS\uff08\u5982\u4e09\u6c1f\u4e59\u9178\uff09\u88ab\u5217\u5165\u76d1\u7ba1\u5316\u5408\u7269\u6e05\u5355\uff0c\u5219\u9700\u8981\u9009\u62e9\u4e13\u95e8\u9488\u5bf9\u6781\u6027\u5316\u5408\u7269\u7684\u56fa\u5b9a\u76f8\u7c7b\u578b\u3002\u4ece\u4ee5\u758f\u6c34\u4f5c\u7528\u4e3a\u4fdd\u7559\u673a\u7406\u7684C18\u67f1\u8f6c\u6362\u5230\u4ee5\u79bb\u5b50\u4ea4\u6362\u548cHILIC\u5206\u79bb\u6a21\u5f0f\u7684Raptor Polar X\u67f1\uff0c\u4ece\u800c\u5b9e\u73b0\u5bf9\u8d85\u77ed\u94fePFAS\u7684\u5145\u5206\u4fdd\u7559\u3002\u9664\u8d85\u77ed\u94fePFAS\u5916\uff0cRaptor Polar X\u67f1\u8fd8\u80fd\u591f\u5728\u540c\u4e00\u5206\u6790\u4e2d\u4fdd\u7559\u548c\u5206\u79bb\u77ed\u94fe\u3001\u4f20\u7edfPFAS\u53ca\u66ff\u4ee3\u5316\u5408\u7269\uff0c\u63d0\u4f9b\u6700\u5168\u9762\u7684PFAS\u65b9\u6cd5\u65b9\u6cd5\uff0c\u8be6\u89c1\u56fe3\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">\u56fe 3: Raptor Polar X \u5229\u7528\u591a\u79cd\u4fdd\u7559\u6a21\u5f0f\uff0c\u6210\u4e3a\u540c\u65f6\u5206\u6790\u8d85\u77ed\u94fe\u3001\u4f20\u7edf PFAS \u53ca\u66ff\u4ee3\u7269\u7684\u6700\u4f73\u9009\u62e9<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0569.png\" alt=\"Ultrashort- Through Long-Chain and Alternative PFAS on Raptor Polar X\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0569<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">11-Chloroeicosafluoro-3-oxanonane-1-sulfonate (11CL-PF3OUdS)<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">400<\/td><td class=\"oth\">630.78<\/td><td class=\"oth\">450.80<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">9-Chlorohexadecafluoro-3-oxanonane-1-sulfonate (9Cl-PF3ONS)<\/td><td class=\"oth\">1.34<\/td><td class=\"oth\">400<\/td><td class=\"oth\">530.78<\/td><td class=\"oth\">350.85<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanesulfonic acid (PFOS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1763-23-1\/Perfluorooctanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanesulfonic acid (PFOS)<\/a><\/td><td class=\"oth\">1.38<\/td><td class=\"oth\">400<\/td><td class=\"oth\">498.84<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanesulfonic acid (PFHxS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/355-46-4\/Perfluorohexanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanesulfonic acid (PFHxS)<\/a><\/td><td class=\"oth\">1.49<\/td><td class=\"oth\">400<\/td><td class=\"oth\">398.90<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanesulfonic acid (PFBS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-73-5\/Perfluorobutanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanesulfonic acid (PFBS)<\/a><\/td><td class=\"oth\">1.64<\/td><td class=\"oth\">400<\/td><td class=\"oth\">298.97<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\">Perfluoropropanesulfonic acid (PFPrS)<\/td><td class=\"oth\">1.73<\/td><td class=\"oth\">400<\/td><td class=\"oth\">248.97<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\">Perfluoroethanesulfonic acid (PFEtS)<\/td><td class=\"oth\">1.86<\/td><td class=\"oth\">400<\/td><td class=\"oth\">198.98<\/td><td class=\"oth\">79.92<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexafluoropropylene oxide dimer acid (HFPO-DA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13252-13-6\/Hexafluoropropylene oxide dimer acid\" target=\"_blank\" rel=\"noopener\">Hexafluoropropylene oxide dimer acid (HFPO-DA)<\/a><\/td><td class=\"oth\">2.06<\/td><td class=\"oth\">400<\/td><td class=\"oth\">284.97<\/td><td class=\"oth\">168.92<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">2.11<\/td><td class=\"oth\">400<\/td><td class=\"oth\">412.90<\/td><td class=\"oth\">368.91<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/919005-14-4\/Ammonium 4,8-dioxa-3H-perfluorononanoate\" target=\"_blank\" rel=\"noopener\">Ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA)<\/a><\/td><td class=\"oth\">2.15<\/td><td class=\"oth\">400<\/td><td class=\"oth\">376.90<\/td><td class=\"oth\">250.93<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanoic acid (PFHxA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-24-4\/Perfluorohexanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanoic acid (PFHxA)<\/a><\/td><td class=\"oth\">2.36<\/td><td class=\"oth\">400<\/td><td class=\"oth\">312.97<\/td><td class=\"oth\">268.90<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanoic acid (PFBA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-22-4\/Perfluorobutanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanoic acid (PFBA)<\/a><\/td><td class=\"oth\">2.76<\/td><td class=\"oth\">400<\/td><td class=\"oth\">212.97<\/td><td class=\"oth\">168.97<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">Perfluoropropionic acid (PFPrA)<\/td><td class=\"oth\">3.06<\/td><td class=\"oth\">400<\/td><td class=\"oth\">163.03<\/td><td class=\"oth\">119.01<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifluoroacetic acid (TFA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-05-1\/Trifluoroacetic acid\" target=\"_blank\" rel=\"noopener\">Trifluoroacetic acid (TFA)<\/a><\/td><td class=\"oth\">3.77<\/td><td class=\"oth\">400<\/td><td class=\"oth\">113.03<\/td><td class=\"oth\">69.01<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Polar X  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9311A52\" rel=\"noopener\">cat.# 9311A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>50:50 Water:methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>400  ng\/L<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 10 mM ammonium formate, 0.05% formic acid   <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>60:40 Acetonitrile:methanol, 0.05% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>15<\/td><td>85<\/td><\/tr><tr><td>8.00<\/td><td>0.5<\/td><td>15<\/td><td>85<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>To achieve more stable and robust performance with Polar X columns, the recommended LC conditions have changed from those that were used here. The new recommended conditions are an aqueous mobile phase (mobile phase A) consisting of 5 mM or 10 mM ammonium formate with 0.1% formic acid in water and an organic mobile phase (mobile phase B) of 100% acetonitrile. Higher ammonium formate concentrations will result in reduced analyte retention. Therefore, laboratories can optimize retention by adjusting both the ammonium formate concentration and the flow rate to best meet their analytical requirements. In addition, it is recommended that labs evaluate different isocratic conditions by varying the amount of mobile phase B between 70% and 85% acetonitrile. This approach can help labs identify the most suitable separation conditions for their specific target analytes and sample matrices of interest.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A52<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>ultrashort-chain<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0569.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u8272\u8c31\u67f1\u7c92\u5f84\u548c\u9897\u7c92\u7c7b\u578b\u7684\u9009\u62e9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9664\u4e86\u8272\u8c31\u67f1\u7c7b\u578b\u548c\u67f1\u5c3a\u5bf8\u5916\uff0c\u8fd8\u5fc5\u987b\u8003\u8651\u7c92\u5f84\u548c\u9897\u7c92\u7c7b\u578b\u3002\u603b\u4f53\u6765\u8bf4\uff0cRaptor \u7cfb\u5217\u4e2d\u4f7f\u7528\u76842.7\u03bcm\u7684\u6838\u58f3\u9897\u7c92\uff08SPP\uff09\u662f\u9996\u9009\u3002\u4f7f\u7528\u6838\u58f3\u9897\u7c92\u88c5\u586b\u7684\u8272\u8c31\u67f1\u8fdb\u884cPFAS\u5206\u6790\u65f6\u53ef\u4ea7\u751f\u4e0e\u4e9a2\u03bcm\u5168\u591a\u5b54\u9897\u7c92\uff08FPP\uff09\u76f8\u5ab2\u7f8e\u7684\u8272\u8c31\u67f1\u6548\uff0c\u800c\u65e0\u9700\u627f\u53d7\u4e9a2\u03bcm\u9897\u7c92\u76f8\u5e94\u7684\u9ad8\u538b\uff0c\u65e0\u8bba\u662f\u4f7f\u7528UHPLC\u8fd8\u662fHPLC\u4eea\u5668\uff0c\u90fd\u53ef\u4ee5\u5b9e\u73b0\u5feb\u901f\u3001\u9ad8\u6548\u7684\u5206\u6790\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7136\u800c\uff0c\u4eea\u5668\u914d\u7f6e\u7684\u4e0d\u540c\uff0c\u6216\u591a\u6216\u5c11\u4f1a\u5f71\u54cd\u7c92\u5f84\u548c\u9897\u7c92\u7c7b\u578b\u7684\u9009\u62e9\u3002\u4f8b\u5982\uff0c\u4f7f\u7528\u4f20\u7edfHPLC\u4eea\u5668\u5e76\u7ecf\u5e38\u4f7f\u75285\u03bcm\u5168\u591a\u5b54\u9897\u7c92\u8272\u8c31\u67f1\u7684\u5b9e\u9a8c\u5ba4\u53ef\u80fd\u4f1a\u5bf9\u6838\u58f3\u67f1\u6240\u63d0\u4f9b\u7684\u6539\u5584\u611f\u5230\u60ca\u8bb6\uff0c\u65e0\u8bba\u9897\u7c92\u5927\u5c0f\u3002\u4f7f\u7528\u6838\u58f3\u9897\u7c92\u8272\u8c31\u67f1\u65f6\uff0c\u5728\u5927\u591a\u6570HPLC\u4eea\u5668\u53ef\u627f\u53d7\u7684\u538b\u529b\u8303\u56f4\u5185\uff0c\u60a8\u53ef\u4ee5\u5f88\u5bb9\u6613\u5730\u770b\u5230\u5206\u79bb\u6548\u7387\u7684\u63d0\u9ad8\u548c\u66f4\u597d\u7684\u5cf0\u5f62\u3002\u5bf9\u4e8e\u8bb8\u591a\u5e0c\u671b\u4e0d\u652f\u4ed8UHPLC\u4eea\u5668\u8d44\u91d1\u6210\u672c\u7684\u524d\u63d0\u4e0b\u63d0\u9ad8\u5206\u6790\u6548\u7387\u548c\u6837\u54c1\u68c0\u6d4b\u901a\u91cf\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u4e8e\u90a3\u4e9b\u5df2\u7ecf\u4f7f\u7528UHPLC\u4eea\u5668\u7684\u5b9e\u9a8c\u5ba4\u6765\u8bf4\uff0c\u7c92\u5f84\u7684\u9009\u62e9\uff0c\u7279\u522b\u662f\u6838\u58f3\u9897\u7c92\u8272\u8c31\u67f1\u5bf9\u5206\u6790\u6548\u7387\u548c\u5206\u6790\u901f\u5ea6\u7684\u5f71\u54cd\u8f83\u5c0f\u3002\u56fe4\u5c55\u793a\u4e86\u5728UHPLC\u7cfb\u7edf\u4e2d\u4f7f\u7528\u4e09\u652f\u4e0d\u540c\u7c92\u5f84Raptor\u6838\u58f3\u67f1\u5bf9\u4e00\u7ec4PFAS\u5316\u5408\u7269\u5206\u6790\u65f6\u7684\u5bf9\u6bd4\u60c5\u51b5\u3002\u5c3d\u7ba1\u6839\u636e\u4e00\u822c\u8272\u8c31\u539f\u7406\uff0c1.8\u03bcm\u9897\u7c92\u67f1\u7684\u5cf0\u6700\u7a84\uff0c\u4f46\u89c2\u5bdf\u5230\u76845\u03bcm\u548c1.8\u03bcm\u67f1\u7684\u6548\u7387\u5dee\u5f02\u5e76\u4e0d\u663e\u8457\u3002\u7136\u800c\uff0c\u5728\u5b9e\u73b0\u8fd9\u4e9b\u975e\u5e38\u76f8\u4f3c\u7684\u7ed3\u679c\u65f6\u4ea7\u751f\u7684\u80cc\u538b\u5dee\u5f02\u5f88\u5927\uff0c\u7c92\u5f845\u548c2.7\u03bcm\u7684\u8272\u8c31\u67f1\u6240\u4ea7\u751f\u7684\u538b\u529b\u5728\u4f20\u7edfHPLC\u4eea\u5668\u627f\u53d7\u8303\u56f4\u5185\u3002\u4f7f\u7528\u586b\u5145\u6838\u58f3\u9897\u7c92\u7684\u8272\u8c31\u67f1\u5206\u6790PFAS\u7c7b\u5316\u5408\u7269\uff0c\u60a8\u53ef\u4ee5\u5728\u65e0\u9700\u627f\u53d7UHPLC\u538b\u529b\u7684\u60c5\u51b5\u4e0b\u83b7\u5f97UHPLC\u6027\u80fd\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">\u56fe 4\uff1a\u5bf9\u4e8e\u6838\u58f3\u67f1\uff0c\u4e0d\u540c\u7c92\u5f84\u53ef\u4ee5\u83b7\u5f97\u7c7b\u4f3c\u7684\u8272\u8c31\u6027\u80fd\uff0c\u4f46\u9009\u62e9\u7c92\u5f84\u4e3a 2.7 \u6216 5\u03bcm \u7684\u6838\u58f3\u67f1\u53ef\u4ee5\u5c06\u80cc\u538b\u4fdd\u6301\u5728\u4f20\u7edf HPLC \u7cfb\u7edf\u53ef\u627f\u53d7\u8303\u56f4\u5185\uff08\u6240\u6709\u8272\u8c31\u67f1\u5747\u4e3a<br>50mmx2.1mm\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<p class=\"wp-block-paragraph\"><strong>1.8 \u00b5m Raptor C18<\/strong><br>6500\u20138000 psi<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0540.png\" alt=\"Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 \u03bcm)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0540<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304252<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>PFC<\/li><li>PFOA<\/li><li>PFOS<\/li><li>fluorotelomer<\/li><li>perfluorinated compound<\/li><li>perfluoroalkyl<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0540.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>2.7 \u00b5m Raptor C18<\/strong><br>4000\u20135500 psi<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0551.png\" alt=\"Perfluorinated Compounds (PFCs) on Raptor C18 2.7 \u03bcm\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0551<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A52<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>PFC<\/li><li>PFOA<\/li><li>PFOS<\/li><li>fluorotelomer<\/li><li>perfluorinated compound<\/li><li>perfluoroalkyl<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0551.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>5 \u00b5m Raptor C18<\/strong><br>2000\u20133500 psi<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0541.png\" alt=\"Perfluorinated Compounds (PFCs) on Raptor C18 (5 \u03bcm)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0541<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304552<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>PFC<\/li><li>PFOA<\/li><li>PFOS<\/li><li>fluorotelomer<\/li><li>perfluorinated compound<\/li><li>perfluoroalkyl<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0541.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u4fdd\u6301\u5c3d\u53ef\u80fd\u4f4e\u7684\u4eea\u5668\u80cc\u538b\u7684\u540c\u65f6\uff0c\u63d0\u9ad8\u5206\u6790\u6548\u7387\uff08\u901a\u5e38\u8868\u73b0\u6bd4\u8f83\u77ed\u7684\u8fd0\u884c\u65f6\u95f4\uff09\u65b9\u9762\uff0c\u88c5\u586b\u6838\u58f3\u9897\u7c92\u7684\u6db2\u76f8\u8272\u8c31\u67f1\u663e\u7136\u662f\u8d62\u5bb6\u3002\u7136\u800c\uff0c\u8bb8\u591a\u957f\u671f\u4f7f\u7528\u5168\u591a\u5b54\u8272\u8c31\u67f1\u7684\u5b9e\u9a8c\u5ba4\u53ef\u80fd\u66f4\u613f\u610f\u7ee7\u7eed\u4f7f\u7528\u8fd9\u7c7b\u8272\u8c31\u67f1\u3002\u5f53\u7136\uff0c\u5168\u591a\u5b54\u8272\u8c31\u67f1\u53ef\u6210\u529f\u5206\u6790PFAS\u7c7b\u5316\u5408\u7269\u3002\u4e0e\u540c\u7c92\u5f84\u7684\u6838\u58f3\u67f1\uff08RaptorC18\uff09\u76f8\u6bd4\uff0c\u5168\u591a\u5b54\u8272\u8c31\u67f1\uff08\u5982ForceC18\uff09\u7684\u6bd4\u8868\u9762\u79ef\u548c\u78b3\u8f7d\u91cf\u8f83\u9ad8\uff0c\u53ef\u63d0\u9ad8PFAS\u7684\u4fdd\u7559\u6548\u679c\uff08\u56fe5\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">\u56fe 5\uff1a\u5982\u679c\u9996\u9009\u5168\u591a\u5b54\u9897\u7c92\u8272\u8c31\u67f1\uff0cForce C18 \u8272\u8c31\u67f1\u53ef\u4e3a PFAS \u5206\u6790\u63d0\u4f9b\u6709\u6548\u7684\u5206\u79bb\uff08\u6240\u6709\u8272\u8c31\u67f1\u5747\u4e3a 50 mm x 2.1 mm\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<p class=\"wp-block-paragraph\"><strong>1.8 \u00b5m Raptor C18<\/strong><br>6500\u20138000 psi<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0540.png\" alt=\"Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 \u03bcm)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0540<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304252<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>PFC<\/li><li>PFOA<\/li><li>PFOS<\/li><li>fluorotelomer<\/li><li>perfluorinated compound<\/li><li>perfluoroalkyl<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0540.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>1.8 \u00b5m Force C18<\/strong><br>7550\u20139250 psi<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0552.png\" alt=\"Perfluorinated Compounds (PFCs) on Force C18 (1.8 \u03bcm)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0552<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9634252<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>PFC<\/li><li>PFOA<\/li><li>PFOS<\/li><li>fluorotelomer<\/li><li>perfluorinated compound<\/li><li>perfluoroalkyl<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0552.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u7ed3\u8bba<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u9009\u62e9\u9002\u7528\u4e8e\u5206\u6790PFAS\u7684\u8272\u8c31\u67f1\u65f6\uff0c2.7\u03bcm Raptor\u6838\u58f3\u67f1\u5373\u53ef\u4e0eUHPLC\u4e5f\u53ef\u4e0eHPLC\u4eea\u5668\u517c\u5bb9\uff0c\u53ef\u4ee5\u63d0\u4f9b\u51fa\u8272\u7684\u5206\u8fa8\u7387\u3001\u8f83\u77ed\u7684\u8fd0\u884c\u65f6\u95f4\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fa\u5b9a\u76f8\u7684\u9009\u62e9\u53d6\u51b3\u4e8e\u6240\u76d1\u6d4b\u7684PFAS\u8303\u56f4\uff0cRaptor C18\u8272\u8c31\u67f1\u662fC3\u53ca\u4ee5\u4e0a\u94fe\u957fPFAS\u7684\u7edd\u4f73\u9009\u62e9\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5bf9\u4e8e\u540c\u65f6\u5206\u6790\u5305\u62ec\u8d85\u77ed\u94fe\uff08C2-C3\uff09\u3001\u4f20\u7edf\u4e2d\u957f\u94fe\u53caPFAS\u66ff\u4ee3\u7269\u7684\u6700\u4f73\u9009\u62e9\u662fRaptor Polar X\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8bf7\u6ce8\u610f\uff0c\u5bf9\u4e8e\u4f7f\u7528Raptor C18\u8272\u8c31\u67f1\u7684\u75d5\u91cf\u7ea7\u5206\u6790\uff0c\u53ef\u4ee5\u901a\u8fc7\u6dfb\u52a0PFAS\u5ef6\u8fdf\u8272\u8c31\u67f1\u6765\u907f\u514d\u5047\u9633\u6027\u6216\u68c0\u6d4b\u503c\u504f\u9ad8\u3002\u4f7f\u7528PFAS\u5ef6\u8fdf\u67f1\u5c06\u6d88\u9664\u4e0e\u4eea\u5668\u76f8\u5173\u7684\u80cc\u666fPFAS\u6c61\u67d3\u7269\uff0c\u8fd9\u4e9b\u6c61\u67d3\u7269\u53ef\u80fd\u4e0e\u6837\u54c1\u5206\u6790\u7269\u5171\u6d17\u8131\u3002<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A52\">                                \u8d27\u53f7\uff1a 9304A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 2.7 \u00b5m, 50 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A52\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u8d27\u53f7\uff1a 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS Delay Column, 5 \u00b5m, 50 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A1E\">                                \u8d27\u53f7\uff1a 9304A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 2.7 \u00b5m, 100 x 3.0 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A1E\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A52\">                                \u8d27\u53f7\uff1a 9311A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Polar X, 2.7 \u00b5m, 50 x 2.1 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A52\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_3b9a6b-09{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_3b9a6b-09 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id99903_b5fa4b-ad{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id99903_b5fa4b-ad alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column99903_2824bd-5d > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_2824bd-5d{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_2824bd-5d\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading99903_df06fd-cb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading99903_df06fd-cb\"><span class=\"kb-adv-text-inner\">\u60a8\u7684PFAS\u5206\u6790\u9700\u8981\u5e2e\u52a9\u5417\uff1f<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">\u4ece\u65b9\u6cd5\u9009\u62e9\u5230\u4ea7\u54c1\u63a8\u8350\uff0cRestek PFAS \u4e13\u5bb6\u52a9\u60a8\u5e94\u5bf9\u590d\u6742\u5206\u6790\u6d41\u7a0b\uff0c\u83b7\u5f97\u51c6\u786e\u3001\u53ef\u9760\u7684\u5206\u6790\u7ed3\u679c\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns99903_bac608-3f{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns99903_bac608-3f .kt-button{font-weight:normal;font-style:normal;}.kt-btns99903_bac608-3f .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns99903_bac608-3f\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn99903_980c0c-c6.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn99903_980c0c-c6.kb-button:hover .kb-svg-icon-wrap, .kb-btn99903_980c0c-c6.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn99903_980c0c-c6 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/explore.restek.com\/PFAS\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Contact a PFAS<\/strong> <strong>expert<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5982\u679c\u60a8\u6240\u5728\u5b9e\u9a8c\u5ba4\u5f00\u5c55\u5168\u6c1f\u70f7\u57fa\u548c\u591a\u6c1f\u70f7\u57fa\u7269\u8d28\uff08PFAS\uff09\u7684\u6d4b\u8bd5\u5de5\u4f5c\uff0c\u90a3\u60a8\u4e00\u5b9a\u77e5\u9053\uff0c\u968f\u7740\u6211\u4eec\u5bf9\u8fd9\u7c7b\u201c\u6c38\u4e45\u6027\u5316\u5b66\u7269\u8d28\u201d\u7684\u666e\u904d\u6027\u3001\u6301\u4e45\u6027\u548c\u6f5c\u5728\u5065\u5eb7\u98ce\u9669\u7684\u66f4\u591a\u4e86\u89e3\uff0c\u4eba\u4eec\u5bf9\u8fd9\u7c7b\u5316\u5408\u7269\u7684\u5174\u8da3\u6b63\u5728\u4e0d\u65ad\u589e\u957f\u3002\u968f\u4e4b\u5bf9\u5feb\u901f\u3001\u51c6\u786e\u548c\u7cbe\u786e\u5206\u6790\u8fd9\u7c7b\u5316\u5408\u7269\u7684\u9700\u6c42\u4e5f\u5728\u6269\u5927\u3002\u8fd9\u4e9b\u9700\u6c42\u6b63\u63a8\u52a8\u66f4\u597d\u5206\u6790\u65b9\u6cd5\u7684\u51fa\u73b0\uff0c\u800c\u6db2\u76f8\u8272\u8c31\u67f1\u7684\u9009\u62e9\u662f\u6784\u5efa\u65b9\u6cd5\u7684\u57fa\u7840\u3002\u968f\u7740\u8d8a\u6765\u8d8a\u591a\u7684PFAS\u5316\u5408\u7269\u88ab\u5217\u5165\u7ba1\u63a7\u6e05\u5355\uff0c\u7279\u522b\u662f\u5bf9\u8d85\u77ed\u94fePFAS\u5316\u5408\u7269\u7684\u5173\u6ce8\uff0c\u65b0\u65b9\u6cd5\u7684\u5efa\u7acb\u53d8\u5f97\u5c24\u4e3a\u91cd\u8981\u3002\u5728\u8fd9\u91cc\uff0c\u6211\u4eec\u5c06\u4e0e\u5927\u5bb6\u63a2\u8ba8\u5982\u4f55\u6839\u636ePFAS\u76ee\u6807\u5f85\u6d4b\u53bb\u9009\u62e9\u5408\u9002\u7684\u6db2\u76f8\u8272\u8c31\u67f1\u3002 \u56fa\u5b9a\u76f8\u7c7b\u578b\u548c\u89c4\u683c\u7684\u9009\u62e9 \u786e\u5b9a\u60a8\u5c06\u7814\u7a76\u7684PFAS\u5316\u5408\u7269\u8303\u56f4\uff0c\u5bf9\u4e8e\u8272\u8c31\u67f1\u56fa\u5b9a\u76f8\u7684\u9009\u62e9\u6700\u4e3a\u91cd\u8981\u3002\u9009\u62e9\u5bf9\u76ee\u6807\u5f85\u6d4b\u7269\u6709\u826f\u597d\u4fdd\u7559\u7684\u56fa\u5b9a\u76f8\u662f\u65b9\u6cd5\u5efa\u7acb\u7684\u7b2c\u4e00\u6b65\u3002 \u77ed\u94fe\u53ca\u4ee5\u4e0a PFAS \u5f53\u6d89\u53ca\u5230\u77ed\u94fePFAS\uff08C4-C6\uff09\u53ca\u4ee5\u4e0a\u7269\u8d28\u65f6\uff0c\u6211\u4eec\u5bf9\u4e0d\u540c\u7c7b\u578b\u8272\u8c31\u67f1\u5bf9\u6bd4\u540e\u53d1\u73b0\uff0cC18\u662f\u6700\u4f73\u9009\u62e9\u3002\u968f\u7740PFAS\u5206\u5b50\u4e0a\u7684\u70f7\u57fa\u94fe\u53d8\u957f\uff0c\u8fd9\u4e9b\u94fe\u4e0eC18\u914d\u4f53\u4e4b\u95f4\u7684\u76f8\u4e92\u4f5c\u7528\u589e\u52a0\uff0c\u4e3a\u4fdd\u7559\u548c\u5206\u79bb\u63d0\u4f9b\u4e86\u5f88\u597d\u7684\u673a\u5236\u3002\u56e0\u4e3a\u4fdd\u7559\u80fd\u529b\u8db3\u591f\u5f3a\uff0c\u56e0\u6b64\u53ef\u4ee5\u4f7f\u7528\u76f8\u5bf9\u8f83\u77ed\u7684\u7a84\u5185\u5f84\u8272\u8c31\u67f1\u5feb\u901f\u6709\u6548\u5730\u5206\u79bb\u76ee\u6807\u5316\u5408\u7269\u3002\u56fe1\u5c55\u793a\u7684\u662f\u7528RaptorC18\uff0c2.7 \u03bcm\uff0c50&#215;2.1mm\u8272\u8c31\u67f1\u5728\u4e0d\u52308\u5206\u949f\uff08\u603b\u5206\u6790\u65f6\u95f4\u4e3a10\u5206\u949f\uff09\u65f6\u95f4\u5185\u8f7b\u677e\u5206\u79bb\u76ee\u6807\u5316\u5408\u7269\uff0c\u800c\u4e14\u6ee1\u8db3EPA537.1\u996e\u7528\u6c34\u6d4b\u8bd5\u6807\u51c6\u7684\u8981\u6c42\u3002 \u8d85\u77ed\u94fe PFAS \u5f53 C8 PFAS \u88ab\u7981\u7528\u540e\uff0c\u5176\u5b83\u8f83\u77ed\u94fe\u7684PFAS\u5316\u5408\u7269\u88ab\u4f5c\u4e3a\u66ff\u4ee3\u7269\u4f7f\u7528\u3002\u968f\u7740\u53d7\u5173\u6ce8PFAS\u6e05\u5355\u5316\u5408\u7269\u589e\u52a0\uff0cC4 PFAS\u751a\u81f3\u201c\u8d85\u77ed\u94fe\u201d\u7684(C2\u548cC3)\u6b63\u53d7\u5230\u8d8a\u6765\u8d8a\u591a\u7684\u5173\u6ce8\u3002\u968f\u7740\u78b3\u94fe\u7684\u7f29\u77ed\uff0cPFAS\u5316\u5408\u7269\u7684\u6781\u6027\u660e\u663e\u589e\u52a0\uff0c\u5bfc\u81f4\u5176\u5728\u4ee5\u758f\u6c34\u4f5c\u7528\u4e3a\u4e3b\u7684C18\u8272\u8c31\u67f1\u4e0a\u7684\u4fdd\u7559\u8d8a\u6765\u8d8a\u5f31\u3002 \u5bf9\u4e8e\u5168\u6c1f\u4e19\u9178\uff08PFPrA\uff09\u548c\u5168\u6c1f\u4e19\u78fa\u9178\uff08PFPrS\uff09\u7b49C3 PFAS\u5316\u5408\u7269\uff0c\u5f53\u9009\u62e9\u5408\u9002\u7684\u89c4\u683c\u65f6\uff0cC18\u8272\u8c31\u67f1\u4ecd\u7136\u53ef\u4ee5\u5de5\u4f5c\u3002\u5982\u56fe2\u6240\u793a\uff0c Raptor C18\uff0c100 x 3 mm\u663e\u793a\u4e86\u51fa\u8272\u7684\u6027\u80fd\uff0c\u53ef\u4ee5\u572811\u5206\u949f\u65f6\u95f4\u5185\u5feb\u901f\u5206\u6790\u5305\u542bC3\u957f\u5ea6\u7684PFAS\u7c7b\u5316\u5408\u7269\u3002 \u5982\u679c\u6700\u7ec8C2 PFAS\uff08\u5982\u4e09\u6c1f\u4e59\u9178\uff09\u88ab\u5217\u5165\u76d1\u7ba1\u5316\u5408\u7269\u6e05\u5355\uff0c\u5219\u9700\u8981\u9009\u62e9\u4e13\u95e8\u9488\u5bf9\u6781\u6027\u5316\u5408\u7269\u7684\u56fa\u5b9a\u76f8\u7c7b\u578b\u3002\u4ece\u4ee5\u758f\u6c34\u4f5c\u7528\u4e3a\u4fdd\u7559\u673a\u7406\u7684C18\u67f1\u8f6c\u6362\u5230\u4ee5\u79bb\u5b50\u4ea4\u6362\u548cHILIC\u5206\u79bb\u6a21\u5f0f\u7684Raptor Polar X\u67f1\uff0c\u4ece\u800c\u5b9e\u73b0\u5bf9\u8d85\u77ed\u94fePFAS\u7684\u5145\u5206\u4fdd\u7559\u3002\u9664\u8d85\u77ed\u94fePFAS\u5916\uff0cRaptor Polar X\u67f1\u8fd8\u80fd\u591f\u5728\u540c\u4e00\u5206\u6790\u4e2d\u4fdd\u7559\u548c\u5206\u79bb\u77ed\u94fe\u3001\u4f20\u7edfPFAS\u53ca\u66ff\u4ee3\u5316\u5408\u7269\uff0c\u63d0\u4f9b\u6700\u5168\u9762\u7684PFAS\u65b9\u6cd5\u65b9\u6cd5\uff0c\u8be6\u89c1\u56fe3\u3002 \u8272\u8c31\u67f1\u7c92\u5f84\u548c\u9897\u7c92\u7c7b\u578b\u7684\u9009\u62e9 \u9664\u4e86\u8272\u8c31\u67f1\u7c7b\u578b\u548c\u67f1\u5c3a\u5bf8\u5916\uff0c\u8fd8\u5fc5\u987b\u8003\u8651\u7c92\u5f84\u548c\u9897\u7c92\u7c7b\u578b\u3002\u603b\u4f53\u6765\u8bf4\uff0cRaptor \u7cfb\u5217\u4e2d\u4f7f\u7528\u76842.7\u03bcm\u7684\u6838\u58f3\u9897\u7c92\uff08SPP\uff09\u662f\u9996\u9009\u3002\u4f7f\u7528\u6838\u58f3\u9897\u7c92\u88c5\u586b\u7684\u8272\u8c31\u67f1\u8fdb\u884cPFAS\u5206\u6790\u65f6\u53ef\u4ea7\u751f\u4e0e\u4e9a2\u03bcm\u5168\u591a\u5b54\u9897\u7c92\uff08FPP\uff09\u76f8\u5ab2\u7f8e\u7684\u8272\u8c31\u67f1\u6548\uff0c\u800c\u65e0\u9700\u627f\u53d7\u4e9a2\u03bcm\u9897\u7c92\u76f8\u5e94\u7684\u9ad8\u538b\uff0c\u65e0\u8bba\u662f\u4f7f\u7528UHPLC\u8fd8\u662fHPLC\u4eea\u5668\uff0c\u90fd\u53ef\u4ee5\u5b9e\u73b0\u5feb\u901f\u3001\u9ad8\u6548\u7684\u5206\u6790\u3002 \u7136\u800c\uff0c\u4eea\u5668\u914d\u7f6e\u7684\u4e0d\u540c\uff0c\u6216\u591a\u6216\u5c11\u4f1a\u5f71\u54cd\u7c92\u5f84\u548c\u9897\u7c92\u7c7b\u578b\u7684\u9009\u62e9\u3002\u4f8b\u5982\uff0c\u4f7f\u7528\u4f20\u7edfHPLC\u4eea\u5668\u5e76\u7ecf\u5e38\u4f7f\u75285\u03bcm\u5168\u591a\u5b54\u9897\u7c92\u8272\u8c31\u67f1\u7684\u5b9e\u9a8c\u5ba4\u53ef\u80fd\u4f1a\u5bf9\u6838\u58f3\u67f1\u6240\u63d0\u4f9b\u7684\u6539\u5584\u611f\u5230\u60ca\u8bb6\uff0c\u65e0\u8bba\u9897\u7c92\u5927\u5c0f\u3002\u4f7f\u7528\u6838\u58f3\u9897\u7c92\u8272\u8c31\u67f1\u65f6\uff0c\u5728\u5927\u591a\u6570HPLC\u4eea\u5668\u53ef\u627f\u53d7\u7684\u538b\u529b\u8303\u56f4\u5185\uff0c\u60a8\u53ef\u4ee5\u5f88\u5bb9\u6613\u5730\u770b\u5230\u5206\u79bb\u6548\u7387\u7684\u63d0\u9ad8\u548c\u66f4\u597d\u7684\u5cf0\u5f62\u3002\u5bf9\u4e8e\u8bb8\u591a\u5e0c\u671b\u4e0d\u652f\u4ed8UHPLC\u4eea\u5668\u8d44\u91d1\u6210\u672c\u7684\u524d\u63d0\u4e0b\u63d0\u9ad8\u5206\u6790\u6548\u7387\u548c\u6837\u54c1\u68c0\u6d4b\u901a\u91cf\u3002 \u5bf9\u4e8e\u90a3\u4e9b\u5df2\u7ecf\u4f7f\u7528UHPLC\u4eea\u5668\u7684\u5b9e\u9a8c\u5ba4\u6765\u8bf4\uff0c\u7c92\u5f84\u7684\u9009\u62e9\uff0c\u7279\u522b\u662f\u6838\u58f3\u9897\u7c92\u8272\u8c31\u67f1\u5bf9\u5206\u6790\u6548\u7387\u548c\u5206\u6790\u901f\u5ea6\u7684\u5f71\u54cd\u8f83\u5c0f\u3002\u56fe4\u5c55\u793a\u4e86\u5728UHPLC\u7cfb\u7edf\u4e2d\u4f7f\u7528\u4e09\u652f\u4e0d\u540c\u7c92\u5f84Raptor\u6838\u58f3\u67f1\u5bf9\u4e00\u7ec4PFAS\u5316\u5408\u7269\u5206\u6790\u65f6\u7684\u5bf9\u6bd4\u60c5\u51b5\u3002\u5c3d\u7ba1\u6839\u636e\u4e00\u822c\u8272\u8c31\u539f\u7406\uff0c1.8\u03bcm\u9897\u7c92\u67f1\u7684\u5cf0\u6700\u7a84\uff0c\u4f46\u89c2\u5bdf\u5230\u76845\u03bcm\u548c1.8\u03bcm\u67f1\u7684\u6548\u7387\u5dee\u5f02\u5e76\u4e0d\u663e\u8457\u3002\u7136\u800c\uff0c\u5728\u5b9e\u73b0\u8fd9\u4e9b\u975e\u5e38\u76f8\u4f3c\u7684\u7ed3\u679c\u65f6\u4ea7\u751f\u7684\u80cc\u538b\u5dee\u5f02\u5f88\u5927\uff0c\u7c92\u5f845\u548c2.7\u03bcm\u7684\u8272\u8c31\u67f1\u6240\u4ea7\u751f\u7684\u538b\u529b\u5728\u4f20\u7edfHPLC\u4eea\u5668\u627f\u53d7\u8303\u56f4\u5185\u3002\u4f7f\u7528\u586b\u5145\u6838\u58f3\u9897\u7c92\u7684\u8272\u8c31\u67f1\u5206\u6790PFAS\u7c7b\u5316\u5408\u7269\uff0c\u60a8\u53ef\u4ee5\u5728\u65e0\u9700\u627f\u53d7UHPLC\u538b\u529b\u7684\u60c5\u51b5\u4e0b\u83b7\u5f97UHPLC\u6027\u80fd\u3002 \u5728\u4fdd\u6301\u5c3d\u53ef\u80fd\u4f4e\u7684\u4eea\u5668\u80cc\u538b\u7684\u540c\u65f6\uff0c\u63d0\u9ad8\u5206\u6790\u6548\u7387\uff08\u901a\u5e38\u8868\u73b0\u6bd4\u8f83\u77ed\u7684\u8fd0\u884c\u65f6\u95f4\uff09\u65b9\u9762\uff0c\u88c5\u586b\u6838\u58f3\u9897\u7c92\u7684\u6db2\u76f8\u8272\u8c31\u67f1\u663e\u7136\u662f\u8d62\u5bb6\u3002\u7136\u800c\uff0c\u8bb8\u591a\u957f\u671f\u4f7f\u7528\u5168\u591a\u5b54\u8272\u8c31\u67f1\u7684\u5b9e\u9a8c\u5ba4\u53ef\u80fd\u66f4\u613f\u610f\u7ee7\u7eed\u4f7f\u7528\u8fd9\u7c7b\u8272\u8c31\u67f1\u3002\u5f53\u7136\uff0c\u5168\u591a\u5b54\u8272\u8c31\u67f1\u53ef\u6210\u529f\u5206\u6790PFAS\u7c7b\u5316\u5408\u7269\u3002\u4e0e\u540c\u7c92\u5f84\u7684\u6838\u58f3\u67f1\uff08RaptorC18\uff09\u76f8\u6bd4\uff0c\u5168\u591a\u5b54\u8272\u8c31\u67f1\uff08\u5982ForceC18\uff09\u7684\u6bd4\u8868\u9762\u79ef\u548c\u78b3\u8f7d\u91cf\u8f83\u9ad8\uff0c\u53ef\u63d0\u9ad8PFAS\u7684\u4fdd\u7559\u6548\u679c\uff08\u56fe5\uff09\u3002 \u7ed3\u8bba \u5728\u9009\u62e9\u9002\u7528\u4e8e\u5206\u6790PFAS\u7684\u8272\u8c31\u67f1\u65f6\uff0c2.7\u03bcm Raptor\u6838\u58f3\u67f1\u5373\u53ef\u4e0eUHPLC\u4e5f\u53ef\u4e0eHPLC\u4eea\u5668\u517c\u5bb9\uff0c\u53ef\u4ee5\u63d0\u4f9b\u51fa\u8272\u7684\u5206\u8fa8\u7387\u3001\u8f83\u77ed\u7684\u8fd0\u884c\u65f6\u95f4\u3002 \u56fa\u5b9a\u76f8\u7684\u9009\u62e9\u53d6\u51b3\u4e8e\u6240\u76d1\u6d4b\u7684PFAS\u8303\u56f4\uff0cRaptor C18\u8272\u8c31\u67f1\u662fC3\u53ca\u4ee5\u4e0a\u94fe\u957fPFAS\u7684\u7edd\u4f73\u9009\u62e9\u3002 \u5bf9\u4e8e\u540c\u65f6\u5206\u6790\u5305\u62ec\u8d85\u77ed\u94fe\uff08C2-C3\uff09\u3001\u4f20\u7edf\u4e2d\u957f\u94fe\u53caPFAS\u66ff\u4ee3\u7269\u7684\u6700\u4f73\u9009\u62e9\u662fRaptor Polar X\u3002 \u8bf7\u6ce8\u610f\uff0c\u5bf9\u4e8e\u4f7f\u7528Raptor C18\u8272\u8c31\u67f1\u7684\u75d5\u91cf\u7ea7\u5206\u6790\uff0c\u53ef\u4ee5\u901a\u8fc7\u6dfb\u52a0PFAS\u5ef6\u8fdf\u8272\u8c31\u67f1\u6765\u907f\u514d\u5047\u9633\u6027\u6216\u68c0\u6d4b\u503c\u504f\u9ad8\u3002\u4f7f\u7528PFAS\u5ef6\u8fdf\u67f1\u5c06\u6d88\u9664\u4e0e\u4eea\u5668\u76f8\u5173\u7684\u80cc\u666fPFAS\u6c61\u67d3\u7269\uff0c\u8fd9\u4e9b\u6c61\u67d3\u7269\u53ef\u80fd\u4e0e\u6837\u54c1\u5206\u6790\u7269\u5171\u6d17\u8131\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[786],"tags":[],"industries-application":[2189,2185],"post-badge":[],"resource-type":[],"product-library":[2427,2409],"resource-technique":[2361,2310,2312],"ppma_author":[414],"class_list":["post-104049","post","type-post","status-publish","format-standard","hentry","category-articles-zh","industries-application-pfas-testing-zh","industries-application-environmental-zh","product-library-lc-columns-zh","product-library-liquid-chromatography-products-zh","resource-technique-ms-ms-zh","resource-technique-liquid-chromatography-zh","resource-technique-mass-spectrometry-ms-zh"],"acf":[],"taxonomy_info":{"category":[{"value":786,"label":"\u6587\u7ae0"}],"industries-application":[{"value":2189,"label":"PFAS\u68c0\u6d4b"},{"value":2185,"label":"\u73af\u5883"}],"product-library":[{"value":2427,"label":"LC\u8272\u8c31\u67f1"},{"value":2409,"label":"\u6db2\u76f8\u8272\u8c31\u76f8\u5173\u4ea7\u54c1"}],"resource-technique":[{"value":2361,"label":"MS\/MS"},{"value":2310,"label":"\u6db2\u76f8\u8272\u8c31"},{"value":2312,"label":"\u8d28\u8c31 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":786,"name":"\u6587\u7ae0","slug":"articles-zh","term_group":0,"term_taxonomy_id":786,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":786,"category_count":509,"category_description":"","cat_name":"\u6587\u7ae0","category_nicename":"articles-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/104049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=104049"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/104049\/revisions"}],"predecessor-version":[{"id":104052,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/104049\/revisions\/104052"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=104049"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=104049"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=104049"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=104049"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=104049"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=104049"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=104049"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=104049"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=104049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}