{"id":104062,"date":"2026-06-25T14:00:00","date_gmt":"2026-06-25T14:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=104062"},"modified":"2026-09-21T08:31:13","modified_gmt":"2026-09-21T08:31:13","slug":"lab-supplies-for-pfas-analysis","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles-zh\/lab-supplies-for-pfas-analysis\/","title":{"rendered":"PFAS \u5206\u6790\u5b9e\u9a8c\u5ba4\u8017\u6750\u6307\u5357"},"content":{"rendered":"\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u57fa\u4e8e\u65b9\u6cd5\u7684 PFAS \u5206\u6790\u8017\u6750\u53c2\u8003\u6307\u5357<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5168\u6c1f\u548c\u591a\u6c1f\u70f7\u57fa\u7269\u8d28\uff08Per- and Polyfluoroalkyl Substances\uff0cPFAS\uff09\u5e38\u88ab\u79f0\u4e3a&#8221;\u6c38\u4e45\u5316\u5b66\u54c1&#8221;\uff0c\u5728\u73af\u5883\u4e2d\u65e0\u5904\u4e0d\u5728\uff1b\u540c\u65f6\uff0cPFAS \u4e5f\u5e38\u89c1\u4e8e\u5b9e\u9a8c\u5ba4\u8017\u6750\u4e43\u81f3\u5206\u6790\u4eea\u5668\u4e4b\u4e2d\uff0c\u56e0\u6b64\u9632\u6b62\u672c\u5e95\u6765\u6e90\u6c61\u67d3\u5f85\u6d4b\u6837\u54c1\u81f3\u5173\u91cd\u8981\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS \u5316\u5408\u7269\u8fd8\u53ef\u80fd\u5177\u6709\u8f83\u5f3a\u7684\u5438\u9644\u503e\u5411\uff0c\u6613\u9644\u7740\u4e8e\u91c7\u6837\u548c\u5206\u6790\u8fc7\u7a0b\u4e2d\u5e38\u7528\u7684\u67d0\u4e9b\u6750\u6599\u8868\u9762\uff08\u5982\u73bb\u7483\u5bb9\u5668\u6216\u79fb\u6db2\u7ba1\uff09\u3002\u56e0\u6b64\uff0c\u6837\u54c1\u6d41\u8def\u4e2d\u7684\u6bcf\u4e00\u4e2a\u73af\u8282\u5747\u9700\u8bc4\u4f30\u5176\u5f15\u5165\u672c\u5e95 PFAS \u5316\u5408\u7269\u6216\u5438\u9644\u5f85\u6d4b\u6837\u54c1\u4e2d\u5df2\u6709 PFAS \u7684\u53ef\u80fd\u6027\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS \u6c61\u67d3\u6216\u5438\u9644\u7684\u98ce\u9669\u4f7f\u5206\u6790\u5b9e\u9a8c\u5ba4\u8017\u6750\u7684\u9009\u62e9\u9887\u5177\u6311\u6218\uff0c\u800c\u5404\u8054\u90a6\u673a\u6784\u53d1\u5e03\u7684\u4f17\u591a\u65b9\u6cd5\u53c8\u8fdb\u4e00\u6b65\u589e\u52a0\u4e86\u590d\u6742\u6027\u2014\u2014\u8fd9\u4e9b\u65b9\u6cd5\u5728\u76ee\u6807\u7269\u5206\u6790\u4e0e\u975e\u76ee\u6807\u7269\u5206\u6790\u4e2d\u91c7\u7528\u4e0d\u540c\u7684\u6837\u54c1\u524d\u5904\u7406\u6d41\u7a0b\u548c\u5206\u6790\u4ea7\u54c1\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u9700\u6d4b\u5b9a\u81ea\u6765\u6c34\u4e2d\u5904\u4e8e\u6216\u4f4e\u4e8e\u62a5\u544a\u9650\uff08Reporting Limit\uff09\u7684\u75d5\u91cf PFAS \u65f6\uff0c\u5b9e\u9a8c\u5ba4\u8017\u6750\u7684\u9009\u62e9\u96be\u5ea6\u8fdb\u4e00\u6b65\u589e\u52a0\uff1b\u800c\u5728\u5206\u6790\u73b0\u884c\u653f\u5e9c\u65b9\u6cd5\u6216\u6307\u5357\u5c1a\u672a\u6db5\u76d6\u7684\u5316\u5408\u7269\uff08\u5982\u77ed\u94fe\u548c\u8d85\u77ed\u94fe PFAS\uff09\u65f6\uff0c\u6311\u6218\u5219\u66f4\u4e3a\u7a81\u51fa\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0b\u6587\u7684\u4ea7\u54c1\u6307\u5357\u8868\u683c\u53ef\u7b80\u5316\u9002\u7528\u4ea7\u54c1\u7684\u7b5b\u9009\uff0c\u8fd9\u4e9b\u8868\u683c\u8be6\u7ec6\u5217\u51fa\u4e86\u9002\u7528\u4e8e\u5168\u7403\u5e7f\u6cdb\u8ba4\u53ef\u7684\u68c0\u6d4b\u914d\u7f6e\u548c\u65b9\u6cd5\u7684 PFAS \u5206\u6790\u5b9e\u9a8c\u5ba4\u8017\u6750\uff0c\u4f8b\u5982 <a href=\"https:\/\/discover.restek.com\/articles-fr\/evar4284\/pfas-analysis-by-us-epa-method-537-1-for-drinking-water\">EPA 537.1\uff08\u996e\u7528\u6c34\uff09<\/a> \u53ca <a href=\"https:\/\/discover.restek.com\/articles\/evar4304\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater\">ASTM D7979-20\uff08\u6c34\u3001\u6c61\u6ce5\u3001\u8fdb\u6c34\u3001\u51fa\u6c34\u548c\u5e9f\u6c34\uff09<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u8ff0\u8868\u683c\u5171\u540c\u6db5\u76d6\u4e86\u7f8e\u56fd\u673a\u6784\uff08CDC\u3001EPA\u3001FDA \u548c USDA\uff09\u3001\u6b27\u6d32\u673a\u6784\uff08DIN\uff09\u4ee5\u53ca ASTM\u3001ISO \u7b49\u56fd\u9645\u6807\u51c6\u7ec4\u7ec7\u53d1\u5e03\u7684\u65b9\u6cd5\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5728\u9009\u5b9a\u8ba4\u8bc1\u5b9e\u9a8c\u5ba4\u6240\u7528\u4e14\u7b26\u5408\u65b9\u6cd5\u8981\u6c42\u7684\u4ea7\u54c1\u540e\uff0c\u5e94\u5bf9\u5206\u6790\u7cfb\u7edf\u548c\u8017\u6750\u8fdb\u884c\u8bc4\u4f30\uff0c\u4ee5\u786e\u8ba4\u5176\u4e0d\u542b\u76ee\u6807\u7269\u5e76\u6ee1\u8db3\u65b9\u6cd5\u6240\u8981\u6c42\u7684\u5206\u6790\u6c34\u5e73\uff0c\u4ece\u800c\u63d0\u9ad8\u6570\u636e\u8d28\u91cf\u3001\u83b7\u5f97\u53ef\u9760\u7684 PFAS \u68c0\u6d4b\u6570\u636e\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek \u53ef\u4e3a PFAS \u68c0\u6d4b\u5b9e\u9a8c\u5ba4\u63d0\u4f9b\u4f4e\u672c\u5e95\u3001\u9ad8\u8d28\u91cf\u7684\u5b9e\u9a8c\u5ba4\u8017\u6750\u53ca\u4e13\u4e1a\u6280\u672f\u652f\u6301\uff0c\u534f\u52a9\u5b9e\u9a8c\u5ba4\u4f9d\u636e\u4f17\u591a\u5bf9\u4fdd\u62a4\u4eba\u7c7b\u5065\u5eb7\u548c\u73af\u5883\u5065\u5eb7\u81f3\u5173\u91cd\u8981\u7684\u5168\u7403\u68c0\u6d4b\u6807\u51c6\uff0c\u5206\u6790\u4f20\u7edf\u7c7b\u3001\u66ff\u4ee3\u7c7b\u548c\u8d85\u77ed\u94fe PFAS\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u53ef\u6ce8\u518c\u5e76 <a href=\"https:\/\/explore.restek.com\/PFAS-Guides\" target=\"_blank\" rel=\"noopener\">\u5728\u7ebf\u76f4\u63a5\u6bd4\u8f83\u5404\u65b9\u6cd5\u7684\u76ee\u6807\u7269\u6e05\u5355\u548c\u57fa\u8d28<\/a> \u6216\u8bbf\u95ee <a href=\"https:\/\/discover.restek.com\/zh-hans\/pfas-analysis\/\">www.restek.com\/PFAS<\/a> \u6d4f\u89c8\u66f4\u591a PFAS \u6280\u672f\u8d44\u6e90\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u6309\u65b9\u6cd5\u5206\u7c7b\u7684 PFAS \u5316\u5b66\u5206\u6790\u5b9e\u9a8c\u5ba4\u8017\u6750<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0b\u8868\u5217\u51fa\u4e86\u5404\u6c34\u8d28\u68c0\u6d4b\u548c PFAS \u68c0\u6d4b\u65b9\u6cd5\u7684\u63a8\u8350\u4ea7\u54c1\u3002\u5728\u5f00\u5c55\u5b9e\u9a8c\u524d\uff0c\u53ef\u4f7f\u7528 Restek \u514d\u8d39\u7684\u5728\u7ebf <a href=\"https:\/\/ez.restek.com\/proezlc\" target=\"_blank\" rel=\"noopener\">Pro EZLC \u8272\u8c31\u6a21\u62df\u5668<\/a>\uff0c\u53ef\u5728\u6570\u5206\u949f\u5185\u5b8c\u6210 PFAS \u65b9\u6cd5\u5efa\u6a21\u3002\u51c6\u786e\u7684 PFAS \u5206\u6790\u662f\u6cbb\u7406 PFAS \u6c61\u67d3\u3001\u4fdd\u62a4\u6c34\u8d44\u6e90\u7684\u5173\u952e\u7b2c\u4e00\u6b65\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u51c6\u786e\u7684 PFAS \u5206\u6790\u662f\u6cbb\u7406 PFAS \u6c61\u67d3\u548c\u4fdd\u62a4\u6c34\u8d44\u6e90\u7684\u7b2c\u4e00\u6b65\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u6790\u65b9\u6cd5<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/evar4284\/pfas-analysis-by-us-epa-method-537-1-for-drinking-water\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/evar4285\/pfas-analysis-by-us-epa-method-533-for-drinking-water\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4286\/pfas-analysis-by-us-epa-method-1633a-for-aqueous-solid-biosolids-and-tissue\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4287\/pfas-analysis-by-us-epa-method-otm-45-for-emissions\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4289\/pfas-analysis-by-us-epa-method-8327-for-surface-water-groundwater-and-wastewater\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/fsar4290\/pfas-analysis-by-us-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/cfar4291\/pfas-analysis-by-cdc-6304-09-for-serum\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/fsar4292\/pfas-analysis-by-us-fda-c-010-03-for-food-and-feed\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4298\/pfas-analysis-by-din-en-17892-for-drinking-water\"><strong>DIN EN 17892*<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4299\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4300\/pfas-analysis-by-iso-21675-2019-for-water\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/gnar4301\/pfas-analysis-by-iso-23702-1-2023-for-leather\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4303\/pfas-analysis-by-astm-d7968-23-for-soil\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4304\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td colspan=\"16\"><strong>C18 \u8272\u8c31\u67f1<\/strong><\/td><\/tr><tr><td>PFAS \u5ef6\u8fdf\u67f1: 5 \u03bcm, 50 \u00d7 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/27854\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/p\/27854\" target=\"_blank\" rel=\"noopener\">\u8d27\u53f7\uff1a27854<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>PFAS \u5ef6\u8fdf\u67f1: 5 \u03bcm, 50 \u00d7 3.0 mm (<a href=\"https:\/\/www.restek.com\/p\/580959\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/p\/580959\" target=\"_blank\" rel=\"noopener\">\u8d27\u53f7\uff1a580959<\/a>, \u5b9a\u5236\u4ea7\u54c1)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Force C18 FPP \u8272\u8c31\u67f1: 1.8 \u03bcm, 50 \u00d7 2.1 mm(<a href=\"https:\/\/www.restek.com\/p\/9634252\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 9634252<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Raptor C18 SPP \u8272\u8c31\u67f1:<br>2.7 \u03bcm, 50 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9304A52\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 9304A52<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td colspan=\"16\"><em>\u70b9\u51fb\u67e5\u770b\u66f4\u591a\u89c4\u683c\u7684 <\/em><a href=\"https:\/\/www.restek.com\/c\/lc-pfas\" target=\"_blank\" rel=\"noreferrer noopener\">C18 \u8272\u8c31\u67f1<\/a><em>.<\/em><\/td><\/tr><tr><td colspan=\"16\"><strong>\u4e13\u7528\u67f1<\/strong><\/td><\/tr><tr><td>Raptor Polar X\u6db2\u76f8\u8272\u8c31\u67f1\uff0c2.7 \u00b5m\uff0c50 x 2.1 mm(<a href=\"https:\/\/www.restek.com\/p\/9311A52\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 9311A52<\/a>)<\/td><td colspan=\"15\">\u9002\u7528\u4e8e\u91c7\u7528\u7b49\u5ea6\u65b9\u6cd5\u7684\u8d85\u77ed\u94fe\uff08C1-C3\uff09PFAS \u5206\u6790\u3002 <a href=\"https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098\" target=\"_blank\" rel=\"noopener\">\u67e5\u770b\u65b9\u6cd5\uff01<\/a><\/td><\/tr><tr><td>Ultra IBD \u60f0\u6027\u6db2\u76f8\u67f1\uff0c3 \u00b5m\uff0c100 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9175312-t\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/p\/9175312-t\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 9175312-T<\/a>)<\/td><td colspan=\"15\">\u9002\u7528\u4e8e\u91c7\u7528\u68af\u5ea6\u65b9\u6cd5\u7684\u8d85\u77ed\u94fe\u3001\u77ed\u94fe\u3001\u4e2d\u94fe\u548c\u957f\u94fe PFAS \u5206\u6790\uff08C1\u2013C14\uff09\u3002<a href=\"https:\/\/www.restek.com\/articles\/c1-c10-pfas-analysis-in-human-plasma-and-serum\" target=\"_blank\" rel=\"noopener\">\u67e5\u770b\u65b9\u6cd5\uff01<\/a><\/td><\/tr><tr><td colspan=\"16\"><strong>\u4fdd\u62a4\u67f1<\/strong><\/td><\/tr><tr><td>UltraShield UHPLC\u9884\u67f1\u8fc7\u6ee4\u5668\uff0c0.2 \u00b5m\u6ee4\u82af\uff0c\u5355\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/25809\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 25809<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>EXP\u76f4\u8fde\u4fdd\u62a4\u67f1\u5957\uff0c\u7528\u4e8eEXP\u4fdd\u62a4\u67f1\u82af\uff0c\u5305\u62ec\u63a5\u5934\u548c\u5361\u5957<br>(<a href=\"https:\/\/www.restek.com\/p\/25808\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 25808<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Raptor C18 EXP\u4fdd\u62a4\u67f1\u82af\uff0c2.7 \u00b5m\uff0c5 x 2.1 mm\uff0c3\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/9304A0252\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 9304A0252<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u6ce8\uff1a\u6240\u793a\u90e8\u5206\u4ea7\u54c1\u53ef\u80fd\u4e0e\u65b9\u6cd5\u4e2d\u7684\u4ea7\u54c1\u63cf\u8ff0\u4e0d\u5b8c\u5168\u4e00\u81f4\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*DIN EN 17892 \u5728\u9644\u5f55\u4e2d\u5217\u51fa\u4e86\u4ee5\u4e0b\u89c4\u683c\u7684\u8272\u8c31\u67f1\uff1aForce C18 FPP \u8272\u8c31\u67f1\uff1a1.8 \u00b5m\uff0c100 x 3.0 mm\uff08\u8d27\u53f7 963421E\uff09\u4ee5\u53ca Raptor C18 SPP \u8272\u8c31\u67f1\uff1a2.7 \u00b5m\uff0c100 x 2.1 mm\uff08\u8d27\u53f7 9304A12\uff09\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u6837\u54c1\u5904\u7406<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>\u4ea7\u54c1\u7c7b\u522b<\/td><td><strong>\u63cf\u8ff0<\/strong><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/evar4284\/pfas-analysis-by-us-epa-method-537-1-for-drinking-water\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/evar4285\/pfas-analysis-by-us-epa-method-533-for-drinking-water\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4286\/pfas-analysis-by-us-epa-method-1633a-for-aqueous-solid-biosolids-and-tissue\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4287\/pfas-analysis-by-us-epa-method-otm-45-for-emissions\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4289\/pfas-analysis-by-us-epa-method-8327-for-surface-water-groundwater-and-wastewater\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/fsar4290\/pfas-analysis-by-us-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/cfar4291\/pfas-analysis-by-cdc-6304-09-for-serum\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/fsar4292\/pfas-analysis-by-us-fda-c-010-03-for-food-and-feed\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4298\/pfas-analysis-by-din-en-17892-for-drinking-water\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4299\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4300\/pfas-analysis-by-iso-21675-2019-for-water\"><strong>ISO 21675:<\/strong><\/a><br><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4300\/pfas-analysis-by-iso-21675-2019-for-water\"><strong>2019<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/gnar4301\/pfas-analysis-by-iso-23702-1-2023-for-leather\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4303\/pfas-analysis-by-astm-d7968-23-for-soil\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4304\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td colspan=\"17\"><strong>\u542b\u9897\u7c92\u7269\u6837\u54c1\u7684\u9884\u7b5b\u5206\u6216\u8fc7\u6ee4<\/strong><\/td><\/tr><tr><td rowspan=\"3\"><a href=\"https:\/\/www.restek.com\/c\/1338\" target=\"_blank\" rel=\"noopener\">\u9488\u5f0f\u6ee4\u5668<\/a><\/td><td>30mm\u9488\u5934\u8fc7\u6ee4\u5668\uff0c0.45 \u00b5m\uff0c\u5c3c\u9f99\uff0c\u7c89\u8272\uff0c100\u4e2a\/\u5305 (<a href=\"https:\/\/www.restek.com\/p\/23981\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23981<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>30mm\u9488\u5934\u8fc7\u6ee4\u5668\uff0c0.22 \u00b5m\uff0c\u5c3c\u9f99\uff0c\u7c89\u8272\uff0c100\u4e2a\/\u5305 (<a href=\"https:\/\/www.restek.com\/p\/23980\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23980<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>25mm\u9488\u5934\u8fc7\u6ee4\u5668\uff0c0.22 \u00b5m\uff0c\u805a\u4e19\u70ef\uff0c\u84dd\u8272\uff0c\u9c81\u5c14\u9501\uff0c100\u4e2a\/\u5305 (<a href=\"https:\/\/www.restek.com\/p\/28935\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28935<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u73bb\u7483\u68c9<\/td><td>\u53bb\u6d3b\u787c\u7845\u9178\u76d0\u73bb\u7483\u6bdb10g(<a href=\"https:\/\/www.restek.com\/p\/20789\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 20789<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em>\u60a8\u5728\u5bfb\u627e\u8fc7\u6ee4\u6837\u54c1\u74f6\u5417\uff1f\u70b9\u51fb <\/em><a href=\"https:\/\/www.restek.com\/c\/1337?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">\u6b64\u5904<\/a><em>\u6d4f\u89c8\u53ef\u7528\u7684\u6750\u8d28\u548c\u89c4\u683c\u3002<\/em><\/td><\/tr><tr><td colspan=\"17\"><strong>\u6837\u54c1\u91c7\u96c6\u3001\u8f6c\u79fb\u548c\u63d0\u53d6<\/strong><\/td><\/tr><tr><td rowspan=\"5\">SPE (WAX)<\/td><td>Resprep PFAS SPE \u5c0f\u67f1, 6 mL, WAX 150 mg\/GCB 50 mg, 30\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/28930\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28930<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>\u5e26\u52a9\u6ee4\u5242\u7684Resprep PFAS SPE \u5c0f\u67f1\uff0c 6 mL, \u52a9\u6ee4\u5242\uff0c 2000 mg\/WAX 150 mg\/GCB 50 mg, 30\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/28931\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28931<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep\u805a\u5408\u7269SPE\u5c0f\u67f1\uff0cWAX\uff0c6 mL\/500 mg\uff0c30 \u03bcm\uff0c30\u6839\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/28268\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28268<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep\u805a\u5408\u7269SPE\u5c0f\u67f1\uff0cWAX\uff0c6 mL\/200 mg\uff0c30 \u03bcm\uff0c30\u6839\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/28292\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28292<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em>\u66f4\u591a WAX \u56fa\u76f8\u8403\u53d6\u67f1\u89c4\u683c\uff0c\u8bf7\u70b9\u51fb <\/em><a href=\"https:\/\/www.restek.com\/c\/sp-pfas?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">\u6b64\u5904<\/a><em> \u67e5\u770b\u3002<\/em><\/td><\/tr><tr><td>SPE (S-DVB)<\/td><td>Resprep S-DVB SPE\u5c0f\u67f1\uff0c6 mL\/500 mg\uff0c30\u6839\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/28937\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28937<\/a>)<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td><strong>*<\/strong><\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>\u805a\u4e19\u70ef\u6837\u54c1\u50a8\u6db2\u5668<\/td><td>SPE\u7a7a\u7ba1\uff0c\u6837\u54c1\u8d2e\u5b58\u5668\uff0c75 mL\uff0c\u805a\u4e19\u70ef\uff0c12\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/26015\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 26015<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>\u805a\u4e19\u70ef\u63a5\u5934<\/td><td>SPE\u8fde\u63a5\u5668\uff0c1\u30013\u30016\u300110\u621615 mL\uff0c\u805a\u4e19\u70ef\uff0c15\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/26007\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 26007<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">QuEChERS \u8403\u53d6\u76d0<\/td><td>\u4ec5 Q-sep QuEChERS \u8403\u53d6\u76d0\u5305\uff0c\u65e0\u7f13\u51b2 FDA \u65b9\u6cd5\uff0c6 g MgSO4,1.5 g NaCl\uff0c50 \u5305 (<a href=\"https:\/\/www.restek.com\/p\/28898\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28898<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em>\u66f4\u591a QuEChERS \u4ea7\u54c1\uff0c\u8bf7\u70b9\u51fb <\/em><a href=\"https:\/\/www.restek.com\/c\/1134\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1134\" rel=\"noreferrer noopener\">\u6b64\u5904<\/a><em> \u67e5\u770b\u3002<\/em><\/td><\/tr><tr><td>\u6811\u8102<\/td><td>SDVB\u6e05\u6d01\u6811\u8102, 100 g (<a href=\"https:\/\/www.restek.com\/p\/24230\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 24230<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">\u771f\u7a7a\u6b67\u7ba1<\/td><td>Resprep QR-24\u56fa\u76f8\u8403\u53d6\u88c5\u7f6e (<a href=\"https:\/\/www.restek.com\/p\/28299-VM\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28299-VM<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep QR-12\u56fa\u76f8\u8403\u53d6\u88c5\u7f6e(<a href=\"https:\/\/www.restek.com\/p\/28298-VM\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28298-VM<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">\u771f\u7a7a\u6cf5<\/td><td>Chemker 300 PTFE\u771f\u7a7a\u6cf5\uff0c20 L\/min\uff0cAC110 V\uff0c50 Hz (<a href=\"https:\/\/www.restek.com\/p\/27426\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 27426<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>*<\/strong><\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Chemker 300 PTFE\u771f\u7a7a\u6cf5\uff0c18 L\/min\uff0cAC220 V\uff0c50 Hz (<a href=\"https:\/\/www.restek.com\/p\/27427\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 27427<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>*<\/strong><\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>* CDC \u65b9\u6cd5\u57fa\u4e8e\u4f7f\u7528 C8 \u6216 C18 \u56fa\u76f8\u8403\u53d6\uff08Solid Phase Extraction\uff0cSPE\uff09\u6750\u6599\u7684\u81ea\u52a8\u5728\u7ebf SPE\uff1b\u6240\u793a\u4ea7\u54c1\u63a8\u8350\u7528\u4e8e\u79bb\u7ebf SPE\u3002\u66f4\u591a WAX SPE \u5c0f\u67f1\u89c4\u683c\u548c QuEChERS\uff08Quick, Easy, Cheap, Effective, Rugged, and Safe\uff09\u4ea7\u54c1\u89c1 restek.com\u3002<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u901a\u7528\u5b9e\u9a8c\u5ba4\u8017\u6750<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/evar4284\/pfas-analysis-by-us-epa-method-537-1-for-drinking-water\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/evar4285\/pfas-analysis-by-us-epa-method-533-for-drinking-water\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4286\/pfas-analysis-by-us-epa-method-1633a-for-aqueous-solid-biosolids-and-tissue\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4287\/pfas-analysis-by-us-epa-method-otm-45-for-emissions\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4289\/pfas-analysis-by-us-epa-method-8327-for-surface-water-groundwater-and-wastewater\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/fsar4290\/pfas-analysis-by-us-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-fr\/cfar4291\/pfas-analysis-by-cdc-6304-09-for-serum\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/fsar4292\/pfas-analysis-by-us-fda-c-010-03-for-food-and-feed\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4298\/pfas-analysis-by-din-en-17892-for-drinking-water\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4299\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4300\/pfas-analysis-by-iso-21675-2019-for-water\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/gnar4301\/pfas-analysis-by-iso-23702-1-2023-for-leather\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4303\/pfas-analysis-by-astm-d7968-23-for-soil\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4304\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles-zh\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td>\u9650\u91cf\u87ba\u7eb9\u805a\u4e19\u70ef\u5c0f\u74f6\uff0c9 mm\uff0c700 \u00b5L\uff0c12 x 32 mm\uff0c100\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/23243\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 23243<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u9650\u91cf\u87ba\u7eb9\u805a\u4e19\u70ef\u5c0f\u74f6\uff0c9 mm\uff0c700 \u00b5L\uff0c12 x 32 mm\uff0c1000\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/23246\" target=\"_blank\" rel=\"noopener\">\u8d27\u53f7 23246<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>2.0 mL\uff0c9 mm\u5b9e\u5fc3\u9876\u805a\u4e59\u70ef\u76d6\uff0c\u87ba\u7eb9\uff0c10\u5bc6\u8033\u539a\u819c\uff0c\u900f\u660e\uff0c100\u4e2a\/\u5305 (<a href=\"https:\/\/www.restek.com\/p\/23244\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 23244<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>2.0 mL\uff0c9 mm\u5b9e\u5fc3\u9876\u805a\u4e59\u70ef\u76d6\uff0c\u87ba\u7eb9\uff0c10\u5bc6\u8033\u539a\u819c\uff0c\u900f\u660e\uff0c1000\u4e2a\/\u5305 (<a href=\"https:\/\/www.restek.com\/p\/23247\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 23247<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u7a7a\u79bb\u5fc3\u7ba1\uff0c50 mL\uff0c\u805a\u4e19\u70ef\uff0c\u5e26\u76d6\uff0c50\u4e2a\/\u5305 (<a href=\"https:\/\/www.restek.com\/p\/25846\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 25846<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u7a7a\u79bb\u5fc3\u7ba1\uff0c50 mL\uff0c\u805a\u4e19\u70ef\uff0c\u5e26\u76d6\uff0c500\u4e2a\/\u5305(<a href=\"https:\/\/www.restek.com\/p\/28290\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 28290<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Norm Ject\u5851\u6599\u6ce8\u5c04\u5668\uff0c10 mL\u9c81\u5c14\u9501\u5934\uff0c100\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/22775\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 22775<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><\/tr><tr><td>Norm Ject\u5851\u6599\u6ce8\u5c04\u5668\uff0c5 mL\u9c81\u5c14\u9501\u5934\uff0c100\u4e2a\u88c5 (<a href=\"https:\/\/www.restek.com\/p\/22774\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 22774<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u6ce8\uff1a\u6240\u793a\u90e8\u5206\u4ea7\u54c1\u53ef\u80fd\u4e0e\u65b9\u6cd5\u4e2d\u7684\u4ea7\u54c1\u63cf\u8ff0\u4e0d\u5b8c\u5168\u4e00\u81f4\u3002<\/em><br>\u67d0\u4e9b ASTM \u65b9\u6cd5\u8981\u6c42\u4f7f\u7528\u73bb\u7483\u6ce8\u5c04\u5668\u3002Norm-Ject \u5851\u6599\u6ce8\u5c04\u5668\u7531\u805a\u4e19\u70ef\/\u805a\u4e59\u70ef\u5236\u6210\uff0c\u53ef\u4f5c\u4e3a\u66ff\u4ee3\u9009\u62e9\u4f7f\u7528\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u6309 EPA OTM-50\uff08GC-MS\uff09\u5206\u6790\u6325\u53d1\u6027\u6c1f\u5316\u5408\u7269\uff08Volatile Fluorinated Compounds\uff0cVFC\uff09\u7684\u63a8\u8350\u4ea7\u54c1<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><strong>EPA OTM-50<\/strong><\/td><\/tr><tr><td colspan=\"2\"><strong><strong>\u4ea7\u54c1 \u2014 \u6837\u54c1\u91c7\u96c6 \/ \u8fd0\u8f93<\/strong><\/strong><\/td><\/tr><tr><td>Silcocan\u7a7a\u6c14\u91c7\u6837\u7f50\uff0c6 L\uff0c\u5e263\u901aSiltek\u5904\u7406\u7684RAVE+\u9600\uff0c\u5e26\u538b\u529b\u8868 (<a href=\"https:\/\/www.restek.com\/p\/27309\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 27309<\/a>)<\/td><td>X<\/td><\/tr><tr><td>Silcocan\u7a7a\u6c14\u91c7\u6837\u7f50\uff0c6 L\uff0c\u5e262\u901aSiltek\u5904\u7406\u7684RAVE+\u9600 (<a href=\"https:\/\/www.restek.com\/p\/27307\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 27307<\/a>)<\/td><td>X<\/td><\/tr><tr><td>Silcocan\u7a7a\u6c14\u91c7\u6837\u7f50\uff0c6 L\uff0c\u65e0\u9600 (<a href=\"https:\/\/www.restek.com\/p\/22092\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 22092<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can\u7a7a\u6c14\u91c7\u6837\u7f50\uff0c6 L\uff0c\u5e263\u901aRAVE+\u9600\uff0c\u5e26\u538b\u529b\u8868(<a href=\"https:\/\/www.restek.com\/p\/27319\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 27319<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can\u7a7a\u6c14\u91c7\u6837\u7f50\uff0c6 L\uff0c\u5e262\u901aRAVE+\u9600 (<a href=\"https:\/\/www.restek.com\/p\/27318\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 27318<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can\u7a7a\u6c14\u91c7\u6837\u7f50\uff0c6 L\uff0c\u65e0\u9600 (<a href=\"https:\/\/www.restek.com\/p\/22096\" target=\"_blank\" rel=\"noreferrer noopener\">\u8d27\u53f7 22096<\/a>)<\/td><td>X<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Restek Corporation, Guide to PFAS testing methods, a global survey of PFAS testing methods and guidelines, Technical article, &nbsp;EVAR3552C-UNV, 2024. <a href=\"https:\/\/discover.restek.com\/zh-hans\/articles-zh\/evar3552\/pfas-%e6%a3%80%e6%b5%8b%e6%96%b9%e6%b3%95%e6%8c%87%e5%8d%97\">https:\/\/www.restek.com\/articles\/guide-to-pfas-testing-methods<\/a><\/li>\n\n\n\n<li>S.H., Liang, J. A. Steimling, ,M. Chang Analysis of ultrashort-chain and short-chain (C1 to C4) per- and polyfluorinated substances in potable and non-potable waters. J. Chromatogr. Open 4 (100098) (2023) <a href=\"https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 537.1, Determination of selected per- and polyfluorinated alkyl substances in drinking water by solid phase extraction and liquid chromatography\/tandem mass spectrometry (LC\/MS\/MS), November 2018. <a href=\"https:\/\/cfpub.epa.gov\/si\/si_public_file_download.cfm?p_download_id=537290&amp;Lab=NERL\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/cfpub.epa.gov\/si\/si_public_file_download.cfm?p_download_id=537290&amp;Lab=NERL<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 533, Determination of per- and polyfluoroalkyl substances in drinking water by isotope dilution anion exchange solid phase extraction and liquid chromatography\/tandem mass spectrometry, November 2019. <a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 1633, Revision A, Analysis of per- and polyfluoroalkyl substances (pfas) in aqueous, solid, biosolids, and tissue samples by LC-MS\/MS, December 2024.&nbsp;<a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2024-12\/method-1633a-december-5-2024-508-compliant.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">www.epa.gov\/system\/files\/documents\/2024-12\/method-1633a-december-5-2024-508-compliant.pdf<\/a>&nbsp;<\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, Other Test Method-45 (OTM-45), Measurement of selected per- and polyfluorinated alkyl substances from stationary sources, January 13, 2021. <a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 8327, Per- and polyfluoroalkyl substances (PFAS) by liquid chromatography\/tandem mass spectrometry (LC\/MS\/MS), July 2021. <a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2021-07\/8327.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/system\/files\/documents\/2021-07\/8327.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Department of Agriculture, Food Safety and Inspection Service, Chemistry Laboratory Guidebook, CLG-PFAS 2.04, Screening, determination, and confirmation of PFAS by UHPLC-MS-MS, February 28, 2023. <a href=\"https:\/\/www.fsis.usda.gov\/sites\/default\/files\/media_file\/documents\/CLG-PFAS2.04.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.fsis.usda.gov\/sites\/default\/files\/media_file\/documents\/CLG-PFAS2.04.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Centers for Disease Control and Prevention,&nbsp;CDC 6304.09, Perfluoroalkyl and polyfluoroalkyl substances, February 2019. <a href=\"https:\/\/wwwn.cdc.gov\/nchs\/data\/nhanes\/public\/2019\/labmethods\/PFAS-K-Met-508.pdf%20\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/wwwn.cdc.gov\/nchs\/data\/nhanes\/public\/2019\/labmethods\/PFAS-K-Met-508.pdf&nbsp;<\/a><\/li>\n\n\n\n<li>U.S. Food and Drug Administration, FDA C-010.02, Determination of 30 per and polyfluoroalkyl substances (PFAS) in food and feed using liquid chromatography-tandem mass spectrometry (LC-MS\/MS), April 12, 2024. <a href=\"https:\/\/www.fda.gov\/media\/131510\/download\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.fda.gov\/media\/131510\/download<\/a> &nbsp;&nbsp;<\/li>\n\n\n\n<li>DIN EN 17892, Water quality-Determination of the sum of perfluorinated substances (Sum of PFAS) in drinking water &#8211; Method using liquid chromatography\/mass spectrometry (LC\/MS), September 2021.<\/li>\n\n\n\n<li>DIN 38407-42, German standard methods for the examination of water, waste water and sludge-Jointly determinable substances (group F)-Part 42: determination of selected polyfluorinated compounds (PFC) in water-Method using high performance liquid chromatography and mass spectrometric detection (HPLC\/MS-MS)after solid-liquid extraction (F 42), March 2011.<\/li>\n\n\n\n<li>ISO 21675:2019, Water quality\u2014Determination of perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water\u2014Method using solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS\/MS), 2019. <a href=\"https:\/\/www.iso.org\/standard\/71338.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.iso.org\/standard\/71338.html<\/a><\/li>\n\n\n\n<li>ASTM D7968-23, Standard test method for determination of polyfluorinated compounds in soil by liquid chromatography tandem mass spectrometry (LC\/MS\/MS), November 6, 2023.<br>&nbsp;<a href=\"https:\/\/www.astm.org\/d7968-23.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d7968-23.html<\/a> &nbsp;<\/li>\n\n\n\n<li>ASTM D7979-20, Standard test method for determination of per- and polyfluoroalkyl substances in water, sludge, influent, effluent, and wastewater by liquid chromatography tandem mass spectrometry (LC\/MS\/MS), September 3, 2020. <a href=\"https:\/\/www.astm.org\/d7979-20.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d7979-20.html<\/a> &nbsp;<\/li>\n\n\n\n<li>ASTM D8421-22, Standard test method for determination of per- and polyfluoroalkyl substances (PFAS) in aqueous matrices by co-solvation followed by liquid chromatography tandem mass spectrometry (LC\/MS\/MS) <a href=\"https:\/\/www.astm.org\/d8421-22.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d8421-22.html<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, Other Test Method-50, OTM-50, Sampling and analysis of volatile fluorinated compounds from stationary sources using passivated stainless-steel canisters, January 2025. <a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2025-01\/otm-50-release-1-r1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/system\/files\/documents\/2025-01\/otm-50-release-1-r1.pdf<\/a><\/li>\n<\/ol>\n\n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_3b9a6b-09{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_3b9a6b-09 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id99903_b5fa4b-ad{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id99903_b5fa4b-ad alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column99903_2824bd-5d > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_2824bd-5d{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_2824bd-5d\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading99903_df06fd-cb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading99903_df06fd-cb\"><span class=\"kb-adv-text-inner\">\u60a8\u7684PFAS\u5206\u6790\u9700\u8981\u5e2e\u52a9\u5417\uff1f<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">\u4ece\u65b9\u6cd5\u9009\u62e9\u5230\u4ea7\u54c1\u63a8\u8350\uff0cRestek PFAS \u4e13\u5bb6\u52a9\u60a8\u5e94\u5bf9\u590d\u6742\u5206\u6790\u6d41\u7a0b\uff0c\u83b7\u5f97\u51c6\u786e\u3001\u53ef\u9760\u7684\u5206\u6790\u7ed3\u679c\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns99903_bac608-3f{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns99903_bac608-3f .kt-button{font-weight:normal;font-style:normal;}.kt-btns99903_bac608-3f .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns99903_bac608-3f\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn99903_980c0c-c6.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn99903_980c0c-c6.kb-button:hover .kb-svg-icon-wrap, .kb-btn99903_980c0c-c6.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn99903_980c0c-c6 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/explore.restek.com\/PFAS\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Contact a PFAS<\/strong> <strong>expert<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column104062_0479e3-df > .kt-inside-inner-col{display:flex;}.kadence-column104062_0479e3-df{max-width:650px;margin-left:auto;margin-right:auto;}.wp-block-kadence-column.kb-section-dir-horizontal:not(.kb-section-md-dir-vertical)>.kt-inside-inner-col>.kadence-column104062_0479e3-df{-webkit-flex:0 1 650px;flex:0 1 650px;max-width:unset;margin-left:unset;margin-right:unset;}.kadence-column104062_0479e3-df > .kt-inside-inner-col{padding-top:var(--global-kb-spacing-md, 2rem);padding-right:var(--global-kb-spacing-md, 2rem);padding-bottom:var(--global-kb-spacing-md, 2rem);padding-left:var(--global-kb-spacing-md, 2rem);}.kadence-column104062_0479e3-df > .kt-inside-inner-col,.kadence-column104062_0479e3-df > .kt-inside-inner-col:before{border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;}.kadence-column104062_0479e3-df > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column104062_0479e3-df > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;align-items:center;}.kadence-column104062_0479e3-df > .kt-inside-inner-col > *, .kadence-column104062_0479e3-df > .kt-inside-inner-col > figure.wp-block-image, .kadence-column104062_0479e3-df > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column104062_0479e3-df > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}.kadence-column104062_0479e3-df > .kt-inside-inner-col{background-image:url('https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-background-texture.jpg');background-size:cover;background-position:center center;background-attachment:scroll;background-repeat:no-repeat;}.kadence-column104062_0479e3-df > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column104062_0479e3-df{position:relative;}@media all and (min-width: 1025px){.wp-block-kadence-column.kb-section-dir-horizontal>.kt-inside-inner-col>.kadence-column104062_0479e3-df{-webkit-flex:0 1 650px;flex:0 1 650px;max-width:unset;margin-left:unset;margin-right:unset;}}@media all and (max-width: 1024px){.kadence-column104062_0479e3-df > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;align-items:center;}}@media all and (min-width: 768px) and (max-width: 1024px){.kadence-column104062_0479e3-df > .kt-inside-inner-col > *, .kadence-column104062_0479e3-df > .kt-inside-inner-col > figure.wp-block-image, .kadence-column104062_0479e3-df > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column104062_0479e3-df > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}}@media all and (max-width: 767px){.wp-block-kadence-column.kb-section-sm-dir-vertical:not(.kb-section-sm-dir-horizontal):not(.kb-section-sm-dir-specificity)>.kt-inside-inner-col>.kadence-column104062_0479e3-df{max-width:650px;-webkit-flex:1;flex:1;margin-left:auto;margin-right:auto;}.kadence-column104062_0479e3-df > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;justify-content:flex-start;}.kadence-column104062_0479e3-df > .kt-inside-inner-col > *, .kadence-column104062_0479e3-df > .kt-inside-inner-col > figure.wp-block-image, .kadence-column104062_0479e3-df > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column104062_0479e3-df > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column104062_0479e3-df kb-section-dir-horizontal\"><div class=\"kt-inside-inner-col\"><style>.kadence-column104062_2b1d00-2d > .kt-inside-inner-col{display:flex;}.kadence-column104062_2b1d00-2d > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column104062_2b1d00-2d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column104062_2b1d00-2d > .kt-inside-inner-col > .aligncenter{width:100%;}.kt-row-column-wrap > .kadence-column104062_2b1d00-2d{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_2b1d00-2d{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_2b1d00-2d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column104062_2b1d00-2d > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column104062_2b1d00-2d{position:relative;}@media all and (max-width: 1024px){.kt-row-column-wrap > .kadence-column104062_2b1d00-2d{align-self:center;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_2b1d00-2d{align-self:auto;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_2b1d00-2d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 1024px){.kadence-column104062_2b1d00-2d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kt-row-column-wrap > .kadence-column104062_2b1d00-2d{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_2b1d00-2d{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_2b1d00-2d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column104062_2b1d00-2d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column104062_2b1d00-2d\"><div class=\"kt-inside-inner-col\">\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\" style=\"margin-top:0px;margin-bottom:0px;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0;font-size:23px\"><strong>PFAS Analysis Simplified<\/strong><\/p>\n\n\n\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-3 wp-block-paragraph\">From product selection to expert guides\u2014everything your workflow needs in one place.<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns104062_4e64c7-c7{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns104062_4e64c7-c7 .kt-button{font-weight:normal;font-style:normal;}.kt-btns104062_4e64c7-c7 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns104062_4e64c7-c7 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns104062_4e64c7-c7 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns104062_4e64c7-c7 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns104062_4e64c7-c7 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns104062_4e64c7-c7 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns104062_4e64c7-c7 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns104062_4e64c7-c7\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn104062_cd249b-90.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn104062_cd249b-90.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;border-top-color:#61b522;border-right-color:#61b522;border-bottom-color:#61b522;border-left-color:#61b522;margin-right:var(--global-kb-spacing-xs, 1rem);}.wp-block-kadence-advancedbtn .kb-btn104062_cd249b-90.kb-button:not(.specificity):not(.extra-specificity){text-decoration:none;}.kb-btn104062_cd249b-90.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn104062_cd249b-90.kb-button:hover .kb-svg-icon-wrap, .kb-btn104062_cd249b-90.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn104062_cd249b-90.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn104062_cd249b-90.kb-button:focus{color:#61b522;background:#0d507d;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn104062_cd249b-90.kb-button{border-top-color:#61b522;border-right-color:#61b522;border-bottom-color:#61b522;border-left-color:#61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn104062_cd249b-90.kb-button{border-top-color:#61b522;border-right-color:#61b522;border-bottom-color:#61b522;border-left-color:#61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn104062_cd249b-90 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/discover.restek.com\/pfas-analysis\/\"><span class=\"kt-btn-inner-text\"><strong>Explore PFAS Portal<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column104062_c3b201-61 > .kt-inside-inner-col{display:flex;}.kadence-column104062_c3b201-61 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column104062_c3b201-61 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column104062_c3b201-61 > .kt-inside-inner-col > .aligncenter{width:100%;}.kt-row-column-wrap > .kadence-column104062_c3b201-61{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_c3b201-61{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_c3b201-61 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column104062_c3b201-61 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column104062_c3b201-61{position:relative;}@media all and (max-width: 1024px){.kt-row-column-wrap > .kadence-column104062_c3b201-61{align-self:center;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_c3b201-61{align-self:auto;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_c3b201-61 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 1024px){.kadence-column104062_c3b201-61 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kt-row-column-wrap > .kadence-column104062_c3b201-61{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_c3b201-61{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column104062_c3b201-61 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column104062_c3b201-61 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column104062_c3b201-61\"><div class=\"kt-inside-inner-col\">\n<figure class=\"wp-block-image size-large has-custom-border\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1024x683.jpg\" alt=\"\" class=\"wp-image-95824\" style=\"border-style:none;border-width:0px;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1024x683.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-300x200.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-768x512.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1536x1025.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-2048x1366.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u57fa\u4e8e\u65b9\u6cd5\u7684 PFAS \u5206\u6790\u8017\u6750\u53c2\u8003\u6307\u5357 \u5168\u6c1f\u548c\u591a\u6c1f\u70f7\u57fa\u7269\u8d28\uff08Per- and Polyfluoroalkyl Substances\uff0cPFAS\uff09\u5e38\u88ab\u79f0\u4e3a&#8221;\u6c38\u4e45\u5316\u5b66\u54c1&#8221;\uff0c\u5728\u73af\u5883\u4e2d\u65e0\u5904\u4e0d\u5728\uff1b\u540c\u65f6\uff0cPFAS \u4e5f\u5e38\u89c1\u4e8e\u5b9e\u9a8c\u5ba4\u8017\u6750\u4e43\u81f3\u5206\u6790\u4eea\u5668\u4e4b\u4e2d\uff0c\u56e0\u6b64\u9632\u6b62\u672c\u5e95\u6765\u6e90\u6c61\u67d3\u5f85\u6d4b\u6837\u54c1\u81f3\u5173\u91cd\u8981\u3002 PFAS \u5316\u5408\u7269\u8fd8\u53ef\u80fd\u5177\u6709\u8f83\u5f3a\u7684\u5438\u9644\u503e\u5411\uff0c\u6613\u9644\u7740\u4e8e\u91c7\u6837\u548c\u5206\u6790\u8fc7\u7a0b\u4e2d\u5e38\u7528\u7684\u67d0\u4e9b\u6750\u6599\u8868\u9762\uff08\u5982\u73bb\u7483\u5bb9\u5668\u6216\u79fb\u6db2\u7ba1\uff09\u3002\u56e0\u6b64\uff0c\u6837\u54c1\u6d41\u8def\u4e2d\u7684\u6bcf\u4e00\u4e2a\u73af\u8282\u5747\u9700\u8bc4\u4f30\u5176\u5f15\u5165\u672c\u5e95 PFAS \u5316\u5408\u7269\u6216\u5438\u9644\u5f85\u6d4b\u6837\u54c1\u4e2d\u5df2\u6709 PFAS \u7684\u53ef\u80fd\u6027\u3002 PFAS \u6c61\u67d3\u6216\u5438\u9644\u7684\u98ce\u9669\u4f7f\u5206\u6790\u5b9e\u9a8c\u5ba4\u8017\u6750\u7684\u9009\u62e9\u9887\u5177\u6311\u6218\uff0c\u800c\u5404\u8054\u90a6\u673a\u6784\u53d1\u5e03\u7684\u4f17\u591a\u65b9\u6cd5\u53c8\u8fdb\u4e00\u6b65\u589e\u52a0\u4e86\u590d\u6742\u6027\u2014\u2014\u8fd9\u4e9b\u65b9\u6cd5\u5728\u76ee\u6807\u7269\u5206\u6790\u4e0e\u975e\u76ee\u6807\u7269\u5206\u6790\u4e2d\u91c7\u7528\u4e0d\u540c\u7684\u6837\u54c1\u524d\u5904\u7406\u6d41\u7a0b\u548c\u5206\u6790\u4ea7\u54c1\u3002 \u5f53\u9700\u6d4b\u5b9a\u81ea\u6765\u6c34\u4e2d\u5904\u4e8e\u6216\u4f4e\u4e8e\u62a5\u544a\u9650\uff08Reporting Limit\uff09\u7684\u75d5\u91cf PFAS \u65f6\uff0c\u5b9e\u9a8c\u5ba4\u8017\u6750\u7684\u9009\u62e9\u96be\u5ea6\u8fdb\u4e00\u6b65\u589e\u52a0\uff1b\u800c\u5728\u5206\u6790\u73b0\u884c\u653f\u5e9c\u65b9\u6cd5\u6216\u6307\u5357\u5c1a\u672a\u6db5\u76d6\u7684\u5316\u5408\u7269\uff08\u5982\u77ed\u94fe\u548c\u8d85\u77ed\u94fe PFAS\uff09\u65f6\uff0c\u6311\u6218\u5219\u66f4\u4e3a\u7a81\u51fa\u3002 \u4e0b\u6587\u7684\u4ea7\u54c1\u6307\u5357\u8868\u683c\u53ef\u7b80\u5316\u9002\u7528\u4ea7\u54c1\u7684\u7b5b\u9009\uff0c\u8fd9\u4e9b\u8868\u683c\u8be6\u7ec6\u5217\u51fa\u4e86\u9002\u7528\u4e8e\u5168\u7403\u5e7f\u6cdb\u8ba4\u53ef\u7684\u68c0\u6d4b\u914d\u7f6e\u548c\u65b9\u6cd5\u7684 PFAS \u5206\u6790\u5b9e\u9a8c\u5ba4\u8017\u6750\uff0c\u4f8b\u5982 EPA 537.1\uff08\u996e\u7528\u6c34\uff09 \u53ca ASTM D7979-20\uff08\u6c34\u3001\u6c61\u6ce5\u3001\u8fdb\u6c34\u3001\u51fa\u6c34\u548c\u5e9f\u6c34\uff09. \u4e0a\u8ff0\u8868\u683c\u5171\u540c\u6db5\u76d6\u4e86\u7f8e\u56fd\u673a\u6784\uff08CDC\u3001EPA\u3001FDA \u548c USDA\uff09\u3001\u6b27\u6d32\u673a\u6784\uff08DIN\uff09\u4ee5\u53ca ASTM\u3001ISO \u7b49\u56fd\u9645\u6807\u51c6\u7ec4\u7ec7\u53d1\u5e03\u7684\u65b9\u6cd5\u3002 \u5728\u9009\u5b9a\u8ba4\u8bc1\u5b9e\u9a8c\u5ba4\u6240\u7528\u4e14\u7b26\u5408\u65b9\u6cd5\u8981\u6c42\u7684\u4ea7\u54c1\u540e\uff0c\u5e94\u5bf9\u5206\u6790\u7cfb\u7edf\u548c\u8017\u6750\u8fdb\u884c\u8bc4\u4f30\uff0c\u4ee5\u786e\u8ba4\u5176\u4e0d\u542b\u76ee\u6807\u7269\u5e76\u6ee1\u8db3\u65b9\u6cd5\u6240\u8981\u6c42\u7684\u5206\u6790\u6c34\u5e73\uff0c\u4ece\u800c\u63d0\u9ad8\u6570\u636e\u8d28\u91cf\u3001\u83b7\u5f97\u53ef\u9760\u7684 PFAS \u68c0\u6d4b\u6570\u636e\u3002 Restek \u53ef\u4e3a PFAS \u68c0\u6d4b\u5b9e\u9a8c\u5ba4\u63d0\u4f9b\u4f4e\u672c\u5e95\u3001\u9ad8\u8d28\u91cf\u7684\u5b9e\u9a8c\u5ba4\u8017\u6750\u53ca\u4e13\u4e1a\u6280\u672f\u652f\u6301\uff0c\u534f\u52a9\u5b9e\u9a8c\u5ba4\u4f9d\u636e\u4f17\u591a\u5bf9\u4fdd\u62a4\u4eba\u7c7b\u5065\u5eb7\u548c\u73af\u5883\u5065\u5eb7\u81f3\u5173\u91cd\u8981\u7684\u5168\u7403\u68c0\u6d4b\u6807\u51c6\uff0c\u5206\u6790\u4f20\u7edf\u7c7b\u3001\u66ff\u4ee3\u7c7b\u548c\u8d85\u77ed\u94fe PFAS\u3002 \u53ef\u6ce8\u518c\u5e76 \u5728\u7ebf\u76f4\u63a5\u6bd4\u8f83\u5404\u65b9\u6cd5\u7684\u76ee\u6807\u7269\u6e05\u5355\u548c\u57fa\u8d28 \u6216\u8bbf\u95ee www.restek.com\/PFAS \u6d4f\u89c8\u66f4\u591a PFAS \u6280\u672f\u8d44\u6e90\u3002 \u6309\u65b9\u6cd5\u5206\u7c7b\u7684 PFAS \u5316\u5b66\u5206\u6790\u5b9e\u9a8c\u5ba4\u8017\u6750 \u4e0b\u8868\u5217\u51fa\u4e86\u5404\u6c34\u8d28\u68c0\u6d4b\u548c PFAS \u68c0\u6d4b\u65b9\u6cd5\u7684\u63a8\u8350\u4ea7\u54c1\u3002\u5728\u5f00\u5c55\u5b9e\u9a8c\u524d\uff0c\u53ef\u4f7f\u7528&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[786],"tags":[],"industries-application":[2189,2177,2180,2190,2185,2186,2191,2193,2187],"post-badge":[],"resource-type":[],"product-library":[2410,2435],"resource-technique":[],"ppma_author":[414],"class_list":["post-104062","post","type-post","status-publish","format-standard","hentry","category-articles-zh","industries-application-pfas-testing-zh","industries-application-clinical-zh","industries-application-clinical-toxicology-zh","industries-application-soil-sediment-biota-testing-zh","industries-application-environmental-zh","industries-application-air-monitoring-zh","industries-application-food-beverage-zh","industries-application-food-safety-zh","industries-application-drinking-water-wastewater-testing-zh","product-library-reference-standard-products-zh","product-library-liquid-reference-standards-zh"],"acf":[],"taxonomy_info":{"category":[{"value":786,"label":"\u6587\u7ae0"}],"industries-application":[{"value":2189,"label":"PFAS\u68c0\u6d4b"},{"value":2177,"label":"\u4e34\u5e8a"},{"value":2180,"label":"\u4e34\u5e8a\u6bd2\u7406\u5b66"},{"value":2190,"label":"\u571f\u58e4\u3001\u6c89\u79ef\u7269\u3001\u751f\u7269\u68c0\u6d4b"},{"value":2185,"label":"\u73af\u5883"},{"value":2186,"label":"\u7a7a\u6c14\u76d1\u6d4b"},{"value":2191,"label":"\u98df\u54c1\u548c\u996e\u6599"},{"value":2193,"label":"\u98df\u54c1\u5b89\u5168"},{"value":2187,"label":"\u996e\u7528\u6c34&amp;\u5e9f\u6c34\u68c0\u6d4b"}],"product-library":[{"value":2410,"label":"\u53c2\u8003\u6807\u51c6\u54c1"},{"value":2435,"label":"\u6db2\u4f53\u53c2\u8003\u6807\u51c6\u54c1"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":786,"name":"\u6587\u7ae0","slug":"articles-zh","term_group":0,"term_taxonomy_id":786,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":786,"category_count":510,"category_description":"","cat_name":"\u6587\u7ae0","category_nicename":"articles-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/104062","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=104062"}],"version-history":[{"count":10,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/104062\/revisions"}],"predecessor-version":[{"id":104075,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/104062\/revisions\/104075"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=104062"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=104062"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=104062"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=104062"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=104062"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=104062"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=104062"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=104062"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=104062"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}