{"id":39945,"date":"2020-12-22T01:00:00","date_gmt":"2020-12-22T01:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/syringe-filters-solvent-compatibility-chart\/"},"modified":"2025-11-05T19:24:11","modified_gmt":"2025-11-05T19:24:11","slug":"syringe-filters-solvent-compatibility-chart","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles\/gnss2122\/syringe-filters-solvent-compatibility-chart","title":{"rendered":"Syringe Filters Solvent Compatibility Chart"},"content":{"rendered":"<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>ACIDS<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Acetic, 5%<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Acetic, 10%<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Acetic, 25%<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Acetic, Glacial<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Boric<\/td>\n<td>\u2013<\/td>\n<td>L<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Formic 25%<\/td>\n<td>L<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Hydrochloric 15%<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Hydrochloric 25%<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Hydrochloric concentrated<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Hydrofluoric 10%<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Hydrofluoric 35%<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Nitric 25%<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Nitric 6N, 38%<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Nitric concentrated<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Phosphoric 25%<\/td>\n<td>L<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Sulfuric 25%<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Sulfuric 6N, 29%<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Sulfuric concentrated<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Trichloroacetic 10%<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>ALKALINES<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Ammonium Hydroxide 25%<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Formalin 30%<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Sodium Hydroxide 3N, 12%<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>ALCOHOLS<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Amyl Alcohol<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Benzyl Alcohol<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Butyl Alcohol<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Butyl Cellosolve<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<td>\u2013<\/td>\n<td>L<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Ethanol 70%<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Ethanol 98%<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Ethylene glycol<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Glycerol<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Isobutyl Alcohol<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Isopropanol, <em>n<\/em>-Propanol<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Methanol 98%<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Methyl Cellosolve<\/td>\n<td>L<\/td>\n<td>L<\/td>\n<td>\u2013<\/td>\n<td>L<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Propylene glycol<\/td>\n<td>L<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Phenol, Aqueous 10%<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>HYDROCARBONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Hexane<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<\/tr>\n<tr>\n<td>Xylene<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Kerosene, Gasoline<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Tetrakin, Decalin<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Toluene, benzene<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>HALOGENATED HYDROCARBONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Carbon Tetrachloride<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Chloroform<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Methylene Chloride<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Monochlorobenzene<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Trichloroethylene<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>KETONES<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Acetone<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Cyclohexanone<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Isopropylacetone<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Methyl Ethyl Ketone<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Methyl Isobutyl Ketone<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>ESTERS<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Amyl Acetate<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Amyl Propyl &amp; Butyl Acetate<\/td>\n<td>L<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Benzyl Benzoate<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Butyl Acetate<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Ethyl Acetate &amp; Methyl Acetate<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R\/L<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Isopropyl Myristate<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Methyl Cellosolve Acetate<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Propylene Glycol Acetate<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Tricresyl Phosphate<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Isopropyl Acetate<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>OXIDES &#8211; ETHERS<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Dimethylsulfoxide (DMSO)<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Dioxane &amp; Tetrahydrofuran<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Ethyl Ether<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>L<\/td>\n<\/tr>\n<tr>\n<td>Isopropyl Ether<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>SOLVENTS WITH NITROGEN<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Acetonitrile<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Aniline<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Diethylacetamide<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Dimethyl Formamide<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Pyridine<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>N<\/td>\n<\/tr>\n<tr>\n<td>Triethanolamine<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr style=\"background-color: #d2e9ca;\">\n<td><strong>Group of Substance &amp;<\/strong><br \/><strong>Chemical Reagents<\/strong><\/td>\n<td><a href=\"c\/1668\">Cellulose Acetate<\/a><\/td>\n<td><a href=\"c\/1669\">Nylon<\/a><\/td>\n<td><a href=\"c\/1670\">PES<\/a><\/td>\n<td><a href=\"c\/1667\">PTFE<\/a><\/td>\n<td><a href=\"c\/1671\">PVDF<\/a><\/td>\n<td><a href=\"c\/1672\">PP<\/a><\/td>\n<\/tr>\n<tr style=\"background-color: #e8ecef;\">\n<td style=\"text-align: center;\" colspan=\"7\"><strong>MISCELLANEOUS<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Formaldehyde Solution 30%<\/td>\n<td>L<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<tr>\n<td>Hydrogen Peroxide 30%<\/td>\n<td>N<\/td>\n<td>L<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Pyridine<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>N<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>\u2013<\/td>\n<\/tr>\n<tr>\n<td>Silicone Oil &amp; Mineral Oil<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<td>R<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<figure class=\"wp-block-table\"><table style=\"border-style:none;border-width:0px\"><tbody><tr><td>R =<\/td><td>Recommended. No significant change observed in flow rate or bubble&nbsp;point of the membrane, nor visible indication of chemical attack.<\/td><\/tr><tr><td>L =<\/td><td>Limited Recommended Use. Moderate changes in physical properties.&nbsp;The filter may be suitable for short term, noncritical use.<\/td><\/tr><tr><td>N =<\/td><td>Not Recommended. The membrane may be unstable.<\/td><\/tr><tr><td>\u2013 =<\/td><td>Insufficient Data. Information is not available.&nbsp;Trial testing is recommended.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Top 7 Reasons to Use Restek Syringe Filters<\/h2>\n\n\n\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/syr_filters_ph_so_spe-300x300.jpg\" alt=\"\" class=\"wp-image-29038\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/syr_filters_ph_so_spe-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/syr_filters_ph_so_spe-1024x1024.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/syr_filters_ph_so_spe-150x150.jpg 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/syr_filters_ph_so_spe-768x768.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/syr_filters_ph_so_spe-1536x1536.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/syr_filters_ph_so_spe.jpg 1800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Protect any analytical system.<\/li>\n\n\n\n<li>Extend LC column lifetime.<\/li>\n\n\n\n<li>Achieve more reproducible analyses.<\/li>\n\n\n\n<li>Variety of membranes, porosities, and diameters available.<\/li>\n\n\n\n<li>Luer lock inlet provides strong, leak-tight syringe connection to&nbsp;withstand filtration pressure.<\/li>\n\n\n\n<li>Rugged polypropylene construction\u2014 autoclavable to 121 \u00b0C for&nbsp;15 minutes (75 psi).<\/li>\n\n\n\n<li>Labeled (13, 25, and 30 mm, only) and color coded for easy identification.<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Solvent Compatibility Chart for Syringe Filters<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2784],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2375],"resource-technique":[],"ppma_author":[414],"class_list":["post-39945","post","type-post","status-publish","format-standard","hentry","category-articles","product-library-sample-preparation-products"],"acf":[],"taxonomy_info":{"category":[{"value":2784,"label":"Articles"}],"product-library":[{"value":2375,"label":"Sample Preparation Products"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":2784,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":2784,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":2784,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/39945","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=39945"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/39945\/revisions"}],"predecessor-version":[{"id":61805,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/39945\/revisions\/61805"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=39945"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=39945"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=39945"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=39945"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=39945"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=39945"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=39945"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=39945"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=39945"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}