{"id":39974,"date":"2023-10-20T00:00:00","date_gmt":"2023-10-20T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/restek-soil-gas-samplers\/"},"modified":"2026-01-03T14:55:18","modified_gmt":"2026-01-03T14:55:18","slug":"restek-soil-gas-samplers","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles-zh\/evss4129\/restek-soil-gas-samplers","title":{"rendered":"Restek Soil Gas Samplers"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Restek soil gas samplers are designed for simplicity, reliability, and flexibility, so you can maximize data accuracy while minimizing time, expense, and user error. Available in three popular configurations and a range of flow rates, these samplers are ideal for worry-free soil vapor testing. Because we\u2019ve minimized the number of connections, they are easier to use and have fewer places where leaks can occur.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Simplicity<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Easy to clean and maintain; screw-in frit filter takes just seconds to replace.<\/li>\n\n\n\n<li>Fewer connections mean fewer leaks and a quicker, easier set up.<\/li>\n\n\n\n<li>Ships leak tested for out-of-the box performance.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Reliability<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>All-stainless-steel construction means no sample contamination from degrading O-rings.<\/li>\n\n\n\n<li>Every unit is leak tested (1 x 10<sup>-6<\/sup> mL\/sec) to ensure performance.<\/li>\n\n\n\n<li>Individually laser etched with serial number and flow rate\u2014no more guesswork from lost tags or labels.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Flexibility<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Available in three styles with the most in-demand features.<\/li>\n\n\n\n<li>Choose from Siltek-coated or uncoated stainless steel.<\/li>\n\n\n\n<li>Comes in three common flow rates to meet most sampling needs.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-radius:20px;background-color:#dceefb;padding-top:10px;padding-right:10px;padding-bottom:10px;padding-left:10px\">\n<p class=\"has-text-align-center has-text-color has-link-color has-medium-font-size wp-elements-e8b97a7f586aef52e8f8f42124491ae7 wp-block-paragraph\" style=\"color:#1c396e\"><strong>Style 1<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"548\" height=\"606\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-01.png\" alt=\"\" class=\"wp-image-29788\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-01.png 548w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-01-271x300.png 271w\" sizes=\"auto, (max-width: 548px) 100vw, 548px\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dual gauges<\/li>\n\n\n\n<li>Purge port<\/li>\n\n\n\n<li>RAVEqc quick-connect outlet fitting<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-radius:20px;background-color:#dceefb;padding-top:10px;padding-right:10px;padding-bottom:10px;padding-left:10px\">\n<p class=\"has-text-align-center has-text-color has-link-color has-medium-font-size wp-elements-adf4c6137a71fd0997db15ac22df72ce wp-block-paragraph\" style=\"color:#1c396e\"><strong>Style 2<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"548\" height=\"606\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-02.png\" alt=\"\" class=\"wp-image-29794\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-02.png 548w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-02-271x300.png 271w\" sizes=\"auto, (max-width: 548px) 100vw, 548px\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dual gauges<\/li>\n\n\n\n<li>Purge port<\/li>\n\n\n\n<li>\u00bc&#8221; compression outlet fitting<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-radius:20px;background-color:#dceefb;padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px\">\n<p class=\"has-text-align-center has-text-color has-link-color has-medium-font-size wp-elements-ddb66bd097a1999b11e8803ea1617562 wp-block-paragraph\" style=\"color:#1c396e\"><strong>Style 3<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"548\" height=\"606\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-03.png\" alt=\"\" class=\"wp-image-29800\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-03.png 548w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-style-03-271x300.png 271w\" sizes=\"auto, (max-width: 548px) 100vw, 548px\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Single gauge<\/li>\n\n\n\n<li>RAVEqc quick-connect outlet fitting<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Proven to Be Clean and Inert to Ensure Reliable Soil Gas Sampling Results&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To generate the most accurate data, labs should use soil gas samplers that are clean and inert. To confirm cleanliness, we passed lab air through the samplers and testing it according to Method TO-15A. Inertness was examined by comparing data from a direct measurement of a 200 pptv spiked air canister to data from the same canister when it was connected to the samplers. Results demonstrated that Restek soil gas samplers are extremely clean (0.0 ppb for most compounds) and highly inert with an average recovery for all compounds within 15% of the direct measurement.<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr style=\"background-color: #1c396e; color: #ffffff;\">\n<td><strong>Compound<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Cleanliness<\/strong><br \/><strong>(Avg. ppb)<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Inertness<\/strong><br \/><strong>(Avg. %Recovery)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Propylene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">90%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td style=\"text-align: left;\">Dichlorodifluoromethane (CFC-12)<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">100%<\/td>\n<\/tr>\n<tr>\n<td>1,2-Dichlorotetrafluoroethane (CFC-114)<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">92%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Chloromethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">95%<\/td>\n<\/tr>\n<tr>\n<td>Vinyl chloride<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">92%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,3-Butadiene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">105%<\/td>\n<\/tr>\n<tr>\n<td>Bromomethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">103%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td style=\"text-align: center;\">Chloroethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">95%<\/td>\n<\/tr>\n<tr>\n<td>Trichlorofluoromethane (CFC-11)<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">103%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,1-Dichloroethene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">100%<\/td>\n<\/tr>\n<tr>\n<td>Ethanol*<\/td>\n<td style=\"text-align: center;\">5.1<\/td>\n<td style=\"text-align: center;\">93%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Carbon disulfide*<\/td>\n<td style=\"text-align: center;\">0.8<\/td>\n<td style=\"text-align: center;\">96%<\/td>\n<\/tr>\n<tr>\n<td>1,1,2-Trichlorotrifluoroethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">100%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Acrolein<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">96%<\/td>\n<\/tr>\n<tr>\n<td>Isopropyl alcohol<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">118%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Methylene chloride*<\/td>\n<td style=\"text-align: center;\">0.9<\/td>\n<td style=\"text-align: center;\">111%<\/td>\n<\/tr>\n<tr>\n<td>Acetone*<\/td>\n<td style=\"text-align: center;\">0.5<\/td>\n<td style=\"text-align: center;\">89%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><em>trans<\/em>-1,2-Dichloroethene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">98%<\/td>\n<\/tr>\n<tr>\n<td>Hexane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">114%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,1-Dichloroethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">92%<\/td>\n<\/tr>\n<tr>\n<td>Vinyl acetate<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">104%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><em>cis<\/em>-1,2-Dichloroethene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">107%<\/td>\n<\/tr>\n<tr>\n<td>Cyclohexane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">106%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Chloroform<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">92%<\/td>\n<\/tr>\n<tr>\n<td>Carbon tetrachloride<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">96%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Ethyl acetate<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">111%<\/td>\n<\/tr>\n<tr>\n<td>Tetrahydrofuran<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">105%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,1,1-Trichloroethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">100%<\/td>\n<\/tr>\n<tr>\n<td>2-Butanone (MEK)<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">95%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Heptane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">104%<\/td>\n<\/tr>\n<tr>\n<td>Benzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">102%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,2-Dichloroethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">108%<\/td>\n<\/tr>\n<tr>\n<td>Trichloroethylene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">100%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,2-Dichloropropane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">102%<\/td>\n<\/tr>\n<tr>\n<td>Bromodichloromethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">94%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Methyl methacrylate<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">100%<\/td>\n<\/tr>\n<tr>\n<td>1,4-Dioxane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">110%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><em>cis<\/em>-1,3-Dichloropropene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">95%<\/td>\n<\/tr>\n<tr>\n<td>Toluene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">98%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>4-Methyl-2-2pentanone (MIBK)<\/td>\n<td style=\"text-align: center;\">0.1<\/td>\n<td style=\"text-align: center;\">104%<\/td>\n<\/tr>\n<tr>\n<td>Tetrachloroethene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">102%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><em>trans<\/em>-1,3-Dichloropropene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">99%<\/td>\n<\/tr>\n<tr>\n<td>1,1,2-Trichloroethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">102%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Dibromochloromethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">98%<\/td>\n<\/tr>\n<tr>\n<td>1,2-Dibromoethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">95%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>2-Hexanone (MBK)<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">97%<\/td>\n<\/tr>\n<tr>\n<td>Chlorobenzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">98%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Ethylbenzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">102%<\/td>\n<\/tr>\n<tr>\n<td><em>m<\/em>&#8211; &amp; <em>p<\/em>-Xylene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">100%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td><em>o<\/em>-Xylene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">104%<\/td>\n<\/tr>\n<tr>\n<td>Styrene<\/td>\n<td style=\"text-align: center;\">0.1<\/td>\n<td style=\"text-align: center;\">100%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>Bromoform<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">101%<\/td>\n<\/tr>\n<tr>\n<td>1,1,2,2-Tetrachloroethane<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">102%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>4-Ethyltoluene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">103%<\/td>\n<\/tr>\n<tr>\n<td>1,3,5-Trimethylbenzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">110%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,2,4-Trimethylbenzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">95%<\/td>\n<\/tr>\n<tr>\n<td>1,3-Dichlorobenzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">99%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,4-Dichlorobenzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">106%<\/td>\n<\/tr>\n<tr>\n<td>Benzyl chloride<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">99%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,2-Dichlorobenzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">99%<\/td>\n<\/tr>\n<tr>\n<td>Hexachlorobutadiene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">99%<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1;\">\n<td>1,2,4-Trichlorobenzene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">104%<\/td>\n<\/tr>\n<tr>\n<td>Naphthalene<\/td>\n<td style=\"text-align: center;\">0.0<\/td>\n<td style=\"text-align: center;\">103%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">*Compound present in lab air during testing.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-text-color has-link-color wp-elements-cd97fe7ba66f76a87eb8fe51f9fc6ed2 wp-block-paragraph\" style=\"color:#ff6100;font-size:28px\"><strong>Order Today!<\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-6a7fb50158310c516d895ff8d7a998e3 wp-block-paragraph\" style=\"color:#1c396e;font-size:24px\"><strong>Restek Soil Gas Samplers Ensure Simple, Reliable Soil Vapor Testing<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"720\" height=\"300\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-article-EVSS4129-order-info-header.png\" alt=\"\" class=\"wp-image-29260\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-article-EVSS4129-order-info-header.png 720w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-article-EVSS4129-order-info-header-300x125.png 300w\" sizes=\"auto, (max-width: 720px) 100vw, 720px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td style=\"font-size: 20px; vertical-align: top;\" rowspan=\"6\"><strong>Dual Gauge with Purge Port and RAVEqc Quick-Connect Outlet Fitting<\/strong><\/td>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27255\">180 mL\/min, uncoated (cat.# 27255)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27256\">180 mL\/min, Siltek coated (cat.# 27256)<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27257\">150 mL\/min, uncoated (cat.# 27257)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27258\">150 mL\/min, Siltek coated (cat.# 27258)<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27259\">100 mL\/min, uncoated (cat.# 27259)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27260\">100 mL\/min, Siltek coated (cat.# 27260)<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"font-size: 20px; vertical-align: top;\" rowspan=\"6\"><strong>Dual Gauge with Purge Port and \u00bc&#8221; Compression Outlet Fitting<\/strong><\/td>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27249\">180 mL\/min, uncoated (cat.# 27249)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27250\">180 mL\/min, Siltek coated (cat.# 27250)<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27251\">150 mL\/min, uncoated (cat.# 27251)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27252\">150 mL\/min, Siltek coated (cat.# 27252)<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27253\">100 mL\/min, uncoated (cat.# 27253)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27254\">100 mL\/min, Siltek coated (cat.# 27254)<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"font-size: 20px; vertical-align: top;\" rowspan=\"6\"><strong>Single Gauge (No Purge Port) with RAVEqc Quick-Connect Outlet Fitting<\/strong><\/td>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27243\">180 mL\/min, uncoated (cat.# 27243)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27244\">180 mL\/min, Siltek coated (cat.# 27244)<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27245\">150 mL\/min, uncoated (cat.# 27245)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27246\">150 mL\/min, Siltek coated (cat.# 27246)<\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ecf0f1;\"><a href=\"p\/27247\">100 mL\/min, uncoated (cat.# 27247)<\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"p\/27248\">100 mL\/min, Siltek coated (cat.# 27248)<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Related Products<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27264\">                                \u8d27\u53f7\uff1a 27264                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Discontinued: Air Sampling Bottle Kit, Siltek-Treated Valve with Protective Box<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27264\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27373\">                                \u8d27\u53f7\uff1a 27373                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RAVEqc Quick-Connect Male Valve to 1\/4&quot; Tube End Fitting, Short (1.23&quot;)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27373\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27315\">                                \u8d27\u53f7\uff1a 27315                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">TO-Can Air Sampling Canister, 1 L, with 3-Port RAVE+ Valve with Gauge<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27315\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27301\">                                \u8d27\u53f7\uff1a 27301                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">SilcoCan Air Sampling Canister, 1 L, with 3-Port Siltek-Treated RAVE+  Valve with Gauge<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27301\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26477\">                                \u8d27\u53f7\uff1a 26477                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Discontinued: 2 \u00b5m Frit, for Aura Personal Air Sampler, ea.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26477\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26478\">                                \u8d27\u53f7\uff1a 26478                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">2 \u00b5m Frit, for Aura Personal Air Sampler, 10-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26478\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Learn why Restek soil gas samplers reduce leaks and simplify soil vapor testing. Includes performance data and product details for all models.<\/p>\n","protected":false},"author":11,"featured_media":6799,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[786],"tags":[],"industries-application":[2185,2190],"post-badge":[],"resource-type":[],"product-library":[2407],"resource-technique":[2306],"ppma_author":[414],"class_list":["post-39974","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-zh","industries-application-environmental-zh","industries-application-soil-sediment-biota-testing-zh","product-library-air-gas-sampling-products-zh","resource-technique-air-sampling-zh"],"acf":[],"taxonomy_info":{"category":[{"value":786,"label":"\u6587\u7ae0"}],"industries-application":[{"value":2185,"label":"\u73af\u5883"},{"value":2190,"label":"\u571f\u58e4\u3001\u6c89\u79ef\u7269\u3001\u751f\u7269\u68c0\u6d4b"}],"product-library":[{"value":2407,"label":"\u7a7a\u6c14\u548c\u6c14\u4f53\u91c7\u6837\u4ea7\u54c1"}],"resource-technique":[{"value":2306,"label":"\u7a7a\u6c14\u91c7\u96c6"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVSS4129-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":786,"name":"\u6587\u7ae0","slug":"articles-zh","term_group":0,"term_taxonomy_id":786,"taxonomy":"category","description":"","parent":0,"count":495,"filter":"raw","cat_ID":786,"category_count":495,"category_description":"","cat_name":"\u6587\u7ae0","category_nicename":"articles-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/39974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=39974"}],"version-history":[{"count":14,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/39974\/revisions"}],"predecessor-version":[{"id":79340,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/39974\/revisions\/79340"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media\/6799"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=39974"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=39974"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=39974"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=39974"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=39974"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=39974"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=39974"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=39974"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=39974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}