{"id":42576,"date":"2019-02-22T05:00:00","date_gmt":"2019-02-22T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analyzing-mycotoxins-in-cbd-oil-a-simple-workflow-solution\/"},"modified":"2026-06-25T23:59:27","modified_gmt":"2026-06-25T23:59:27","slug":"analyzing-mycotoxins-in-cbd-oil-a-simple-workflow-solution","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/videos\/gnav4884\/analyzing-mycotoxins-in-cbd-oil-a-simple-workflow-solution","title":{"rendered":"Analyzing Mycotoxins in CBD Oil: A Simple Workflow Solution"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Analyzing Mycotoxins in CBD Oil: A Simple Workflow Solution\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/MRPXtE5wTvY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A growing need is emerging for testing to detect the presence of mycotoxins in both raw plant materials and finished cannabis products in order to protect consumer health and safety. The analysis of mycotoxins in cannabis oils is particularly challenging because the&nbsp;sample&nbsp;lipids can contribute isobaric matrix interferences in addition to general ion suppression,&nbsp;which&nbsp;can reduce accuracy&nbsp;especially&nbsp;at low levels. In this video, a simple pass-through SPE sample cleanup was applied to lipid-rich CBD oils. Excellent chromatographic results were obtained for both aflatoxins and ochratoxins even at 2 ng\/g, indicating that the simplified sample prep technique effectively removed lipid interferences. The SPE sample cleanup was paired with a rapid LC-MS\/MS analysis utilizing a Raptor Biphenyl column.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Resources<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/FFSS2946\/high-throughput-analysis-of-mycotoxins-in-cannabis-cbd-oil-pairs-simplified-cleanup-with-lc-msms-sensitivity\/\">High-Throughput Analysis of Mycotoxins in Cannabis CBD Oil Pairs Simplified Cleanup with LC-MS\/MS Sensitivity<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1788\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Biphenyl Columns<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1628\" target=\"_blank\" rel=\"noopener\">Resprep SPE Cartridges<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks for joining us for this Restek video where we\u2019ll discuss a simple workflow solution for analyzing mycotoxins in CBD oil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Our first step is to weigh 0.25 g of CBD oil into a 2.0 mL amber vial.&nbsp;We\u2019ll then add 10 \u00b5L of our working internal standard into the sample and vortex for 10 seconds.&nbsp;Now, we want to concurrently precipitate the matrix and extract our analytes of interest, so we will add 1 mL of 45:55&nbsp;water:methanol&nbsp;to the sample vial and vortex again, this time for 30 seconds.&nbsp;We\u2019ll then centrifuge the sample for five minutes to pull the solids to the bottom of the tube. Also, we want to centrifuge at 10 \u00b0C to ensure analyte stability.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Our last cleanup step will help us remove any remaining matrix interferences. We\u2019ll use a&nbsp;Resprep&nbsp;C18 SPE cartridge for this. You need to first condition the cartridge with our loading solvent which is 45:55&nbsp;water:methanol. Once our cartridge is ready, we\u2019ll transfer 750 \u00b5L of our sample to it. Then we will use a vacuum manifold to pull the sample through the cartridge and into an autosampler vial.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now we are ready for our LC-MS\/MS analysis. We also used a guard column to help protect our analytical column against any contaminants that remain.&nbsp;The Raptor Biphenyl analytical column gives us the necessary retention, while allowing us to complete the run in under three minutes.&nbsp;Once you\u2019ve established the method according to your lab\u2019s validation SOPs, you\u2019re ready to run your samples and collect data.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thank you for watching. You can find more details of the workflow at this link. And, if you want to see more videos about cannabis analysis, please let us know in the comments and don\u2019t forget to like this video!<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Mycotoxins are a concerning potential contaminant of CBD oils. We\u2019ll show you an easy and fast workflow from sample prep through the LC-MS\/MS analysis.<\/p>\n","protected":false},"author":11,"featured_media":41424,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[8],"tags":[],"industries-application":[2149,2150],"post-badge":[],"resource-type":[],"product-library":[2391,2373,2375,2402],"resource-technique":[2299,2302,2304],"ppma_author":[414],"class_list":["post-42576","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos","industries-application-cannabis","industries-application-hemp-hallucinogens","product-library-lc-columns","product-library-liquid-chromatography-products","product-library-sample-preparation-products","product-library-spe-sle","resource-technique-liquid-chromatography","resource-technique-ms-ms","resource-technique-solid-phase-extraction-spe"],"acf":[],"taxonomy_info":{"category":[{"value":8,"label":"Videos"}],"industries-application":[{"value":2149,"label":"Cannabis"},{"value":2150,"label":"Hemp &amp; Hallucinogens"}],"product-library":[{"value":2391,"label":"LC Columns"},{"value":2373,"label":"Liquid Chromatography Products"},{"value":2375,"label":"Sample Preparation Products"},{"value":2402,"label":"SPE &amp; SLE"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2302,"label":"MS\/MS"},{"value":2304,"label":"Solid-Phase Extraction (SPE)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4884-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"Videos","slug":"videos","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":8,"category_count":138,"category_description":"","cat_name":"Videos","category_nicename":"videos","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/42576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=42576"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/42576\/revisions"}],"predecessor-version":[{"id":78586,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/42576\/revisions\/78586"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media\/41424"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=42576"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=42576"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=42576"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=42576"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=42576"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=42576"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=42576"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=42576"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=42576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}