{"id":43738,"date":"2020-10-19T14:30:00","date_gmt":"2020-10-19T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/cross-reference-for-agilent-syringes\/"},"modified":"2025-12-02T16:21:47","modified_gmt":"2025-12-02T16:21:47","slug":"cross-reference-for-agilent-syringes","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles\/gnot3405\/cross-reference-for-agilent-syringes","title":{"rendered":"Cross Reference for Agilent Syringes"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Listed below are some Hamilton and SGE syringes, cross-referenced to Agilent part numbers for your convenience.&nbsp;For further information or questions, contact your Restek sales representative or technical service.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Similar to Agilent Part #<\/strong><\/td><td><strong>Restek Part #<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>5181-1267<\/td><td><a href=\"https:\/\/www.restek.com\/p\/21212\" target=\"_blank\" rel=\"noreferrer noopener\">21212,<\/a> <a href=\"https:\/\/www.restek.com\/p\/24596\" target=\"_blank\" rel=\"noreferrer noopener\">24596<\/a><\/td><td>10 \u00b5L Standard Syringe, Fixed Needle, 23-26 Gauge<\/td><\/tr><tr><td>5181-1273<\/td><td><a href=\"https:\/\/www.restek.com\/p\/21210\" target=\"_blank\" rel=\"noreferrer noopener\">21210<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24593\" target=\"_blank\" rel=\"noreferrer noopener\">24593<\/a><\/td><td>5 \u00b5L Standard Syringe, Fixed Needle, 23-26 Gauge<\/td><\/tr><tr><td>5181-3319<\/td><td><a href=\"https:\/\/www.restek.com\/p\/20166\" target=\"_blank\" rel=\"noreferrer noopener\">20166<\/a><\/td><td>Needle for 10 \u00b5L Standard Syringe, 23-26 Gauge<\/td><\/tr><tr><td>5181-3321<\/td><td><a href=\"https:\/\/www.restek.com\/p\/24598\" target=\"_blank\" rel=\"noreferrer noopener\">24598<\/a><\/td><td>10 \u00b5L Standard Syringe, Removable Needle, 23-26 Gauge<\/td><\/tr><tr><td>5181-3358<\/td><td><a href=\"https:\/\/www.restek.com\/p\/24919\" target=\"_blank\" rel=\"noreferrer noopener\">24919<\/a><\/td><td>PTFE-Tipped Plunger for 10 \u00b5L Standard Syringe, Removable Needle<\/td><\/tr><tr><td>5181-3360<\/td><td><a href=\"https:\/\/www.restek.com\/p\/21215\" target=\"_blank\" rel=\"noreferrer noopener\">21215<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24600\" target=\"_blank\" rel=\"noreferrer noopener\">24600<\/a><\/td><td>10 \u00b5L Standard Syringe, Fixed Needle, 23-26 Gauge (6-pk.)<\/td><\/tr><tr><td>5181-3365<\/td><td><a href=\"https:\/\/www.restek.com\/p\/21218\" target=\"_blank\" rel=\"noreferrer noopener\">21218<\/a><\/td><td>PTFE-Tipped Plunger for 10 \u00b5L Standard Syringe, Fixed Needle<\/td><\/tr><tr><td>5181-8809<\/td><td><a href=\"https:\/\/www.restek.com\/p\/24894\" target=\"_blank\" rel=\"noreferrer noopener\">24894<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24789\" target=\"_blank\" rel=\"noreferrer noopener\">24789<\/a><\/td><td>10 \u00b5L Gas-tight Syringe, Fixed Needle, 23 Gauge<\/td><\/tr><tr><td>5181-8811<\/td><td><a href=\"https:\/\/www.restek.com\/p\/20164\" target=\"_blank\" rel=\"noreferrer noopener\">20164<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24825\" target=\"_blank\" rel=\"noreferrer noopener\">24825<\/a><\/td><td>Needle for 10 \u00b5L Gas-tight Syringe, 23 Gauge<\/td><\/tr><tr><td>5181-8813<\/td><td><a href=\"https:\/\/www.restek.com\/p\/21224\" target=\"_blank\" rel=\"noreferrer noopener\">21224<\/a><\/td><td>10 \u00b5L Gas-tight Syringe, Removable Needle, 23 Gauge<\/td><\/tr><tr><td>5182-0832<\/td><td><a href=\"https:\/\/www.restek.com\/p\/20166\" target=\"_blank\" rel=\"noreferrer noopener\">20166<\/a><\/td><td>Needle for 5-10 \u00b5L Autosampler Syringe, 23-26 Gauge<\/td><\/tr><tr><td>5182-0834<\/td><td><a href=\"https:\/\/www.restek.com\/p\/20172\" target=\"_blank\" rel=\"noreferrer noopener\">20172<\/a><\/td><td>5 \u00b5L Standard Syringe, Removable Needle, 23 Gauge<\/td><\/tr><tr><td>5182-0835<\/td><td><a href=\"https:\/\/www.restek.com\/p\/21223\" target=\"_blank\" rel=\"noreferrer noopener\">21223<\/a><\/td><td>5 \u00b5L Standard Syringe, Removable Needle, 23-26 Gauge<\/td><\/tr><tr><td>5182-0875<\/td><td><a href=\"https:\/\/www.restek.com\/p\/20170\" target=\"_blank\" rel=\"noreferrer noopener\">20170<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24783\" target=\"_blank\" rel=\"noreferrer noopener\">24783<\/a><\/td><td>5 \u00b5L Standard Syringe, Fixed Needle, 23 Gauge (6-pk.)<\/td><\/tr><tr><td>9301-0713<\/td><td><a href=\"https:\/\/www.restek.com\/p\/20167\" target=\"_blank\" rel=\"noreferrer noopener\">20167<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24785\" target=\"_blank\" rel=\"noreferrer noopener\">24785<\/a><\/td><td>10 \u00b5L Standard Syringe, Fixed Needle, 23 Gauge<\/td><\/tr><tr><td>9301-0714<\/td><td><a href=\"https:\/\/www.restek.com\/p\/24595\" target=\"_blank\" rel=\"noreferrer noopener\">24595<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24784\" target=\"_blank\" rel=\"noreferrer noopener\">24784<\/a><\/td><td>10 \u00b5L Standard Syringe, Fixed Needle, 26 Gauge<\/td><\/tr><tr><td>9301-0725<\/td><td><a href=\"https:\/\/www.restek.com\/p\/20169\" target=\"_blank\" rel=\"noreferrer noopener\">20169<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24787\" target=\"_blank\" rel=\"noreferrer noopener\">24787<\/a><\/td><td>10 \u00b5L Standard Syringe, Fixed Needle, 23 Gauge (6-pk.)<\/td><\/tr><tr><td>9301-0891<\/td><td><a href=\"https:\/\/www.restek.com\/p\/24592\" target=\"_blank\" rel=\"noreferrer noopener\">24592<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24780\" target=\"_blank\" rel=\"noreferrer noopener\">24780<\/a><\/td><td>5 \u00b5L Standard Syringe, Fixed Needle, 26 Gauge<\/td><\/tr><tr><td>9301-0892<\/td><td><a href=\"https:\/\/www.restek.com\/p\/20168\" target=\"_blank\" rel=\"noreferrer noopener\">20168<\/a>, <a href=\"https:\/\/www.restek.com\/p\/24781\" target=\"_blank\" rel=\"noreferrer noopener\">24781<\/a><\/td><td>5 \u00b5L Standard Syringe, Fixed Needle, 23 Gauge<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Needle Gauge for Agilent 7673, 7683, 6850 Syringes<\/h3>\n\n\n<style>.kb-image43738_3dc233-9b .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image43738_3dc233-9b size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"256\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-01-768x256.jpg\" alt=\"\" class=\"kb-img wp-image-22300\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-01-768x256.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-01-300x100.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-01-1024x341.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-01-1536x512.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-01.jpg 1800w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Single Gauge Needle\u201423s (0.64 mm)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The most popular gauge for Agilent 7673.<\/li>\n\n\n\n<li>Best for Merlin Microseal septum and standard septum-equipped GCs.<\/li>\n\n\n\n<li>Packed column injection ports.<\/li>\n\n\n\n<li>Split\/splitless injection ports.<\/li>\n<\/ul>\n\n\n<style>.kb-image43738_24464b-cd .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image43738_24464b-cd size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"256\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-02-768x256.jpg\" alt=\"\" class=\"kb-img wp-image-22306\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-02-768x256.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-02-300x100.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-02-1024x341.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-02-1536x512.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-02.jpg 1800w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Single Gauge Needle\u201426s (0.47 mm)<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>On-column injection ports.<\/li>\n\n\n\n<li>Split\/splitless injection ports.<\/li>\n<\/ul>\n\n\n<style>.kb-image43738_4e6f09-ad .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image43738_4e6f09-ad size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"256\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-03-768x256.jpg\" alt=\"\" class=\"kb-img wp-image-22312\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-03-768x256.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-03-300x100.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-03-1024x341.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-03-1536x512.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3405-03.jpg 1800w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Dual Gauge (Tapered) Needle\u201423s-26s<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Durability of a 23s gauge needle.<\/li>\n\n\n\n<li>Ability of a 26s gauge needle to perform split\/splitless and on-column injections.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Cross reference common Hamilton and SGE syringes, or Agilent part numbers, to conveniently select the right Restek syringe cat.# for your work.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[564],"product-library":[2375],"resource-technique":[2294,2299],"ppma_author":[414],"class_list":["post-43738","post","type-post","status-publish","format-standard","hentry","category-articles","resource-type-cross-reference","product-library-sample-preparation-products","resource-technique-gas-chromatography-gc","resource-technique-liquid-chromatography"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"resource-type":[{"value":564,"label":"Cross Reference"}],"product-library":[{"value":2375,"label":"Sample Preparation Products"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2299,"label":"Liquid Chromatography"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43738","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=43738"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43738\/revisions"}],"predecessor-version":[{"id":70029,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43738\/revisions\/70029"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=43738"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=43738"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=43738"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=43738"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=43738"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=43738"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=43738"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=43738"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=43738"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}