{"id":43758,"date":"2020-10-12T00:00:00","date_gmt":"2020-10-12T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/retention-time-dead-volume-for-methane\/"},"modified":"2026-08-11T17:27:18","modified_gmt":"2026-08-11T17:27:18","slug":"retention-time-dead-volume-for-methane","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/faq\/gnot3425\/retention-time-dead-volume-for-methane","title":{"rendered":"Retention Time (Dead Volume) for Methane"},"content":{"rendered":"<div class=\"row\">\n<div class=\"col-12\">\n<div>\n<div class=\"table-wrap\">\n<table class=\"table table-bordered\" style=\"width: 74.9119%; height: 192.5px;\">\n<tbody>\n<tr style=\"height: 38.5px;\" valign=\"bottom\">\n<td style=\"width: 23.2549%; height: 38.5px;\" align=\"center\"><strong>Column Length<\/strong><\/td>\n<td style=\"width: 35.2941%; height: 38.5px;\" align=\"center\"><strong>Hydrogen @ 40cm\/sec.<\/strong><\/td>\n<td style=\"width: 31.1322%; height: 38.5px;\" align=\"center\"><strong>Helium @ 20cm\/sec.<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 19.25px;\">\n<td style=\"width: 23.2549%; height: 19.25px;\" align=\"center\">10m<\/td>\n<td style=\"width: 35.2941%; height: 19.25px;\" align=\"center\">0.42 min.<\/td>\n<td style=\"width: 31.1322%; height: 19.25px;\" align=\"center\">0.83 min.<\/td>\n<\/tr>\n<tr style=\"height: 19.25px;\">\n<td style=\"width: 23.2549%; height: 19.25px;\" align=\"center\">15m<\/td>\n<td style=\"width: 35.2941%; height: 19.25px;\" align=\"center\">0.63 min.<\/td>\n<td style=\"width: 31.1322%; height: 19.25px;\" align=\"center\">1.25 min.<\/td>\n<\/tr>\n<tr style=\"height: 19.25px;\">\n<td style=\"width: 23.2549%; height: 19.25px;\" align=\"center\">20m<\/td>\n<td style=\"width: 35.2941%; height: 19.25px;\" align=\"center\">0.83 min.<\/td>\n<td style=\"width: 31.1322%; height: 19.25px;\" align=\"center\">1.67 min.<\/td>\n<\/tr>\n<tr style=\"height: 19.25px;\">\n<td style=\"width: 23.2549%; height: 19.25px;\" align=\"center\">30m<\/td>\n<td style=\"width: 35.2941%; height: 19.25px;\" align=\"center\">1.25 min.<\/td>\n<td style=\"width: 31.1322%; height: 19.25px;\" align=\"center\">2.50 min.<\/td>\n<\/tr>\n<tr style=\"height: 19.25px;\">\n<td style=\"width: 23.2549%; height: 19.25px;\" align=\"center\">45m<\/td>\n<td style=\"width: 35.2941%; height: 19.25px;\" align=\"center\">1.88 min.<\/td>\n<td style=\"width: 31.1322%; height: 19.25px;\" align=\"center\">3.75 min.<\/td>\n<\/tr>\n<tr style=\"height: 19.25px;\">\n<td style=\"width: 23.2549%; height: 19.25px;\" align=\"center\">60m<\/td>\n<td style=\"width: 35.2941%; height: 19.25px;\" align=\"center\">2.50 min.<\/td>\n<td style=\"width: 31.1322%; height: 19.25px;\" align=\"center\">5.00 min.<\/td>\n<\/tr>\n<tr style=\"height: 19.25px;\">\n<td style=\"width: 23.2549%; height: 19.25px;\" align=\"center\">75m<\/td>\n<td style=\"width: 35.2941%; height: 19.25px;\" align=\"center\">3.13 min.<\/td>\n<td style=\"width: 31.1322%; height: 19.25px;\" align=\"center\">6.25 min.<\/td>\n<\/tr>\n<tr style=\"height: 19.25px;\">\n<td style=\"width: 23.2549%; height: 19.25px;\" align=\"center\">105m<\/td>\n<td style=\"width: 35.2941%; height: 19.25px;\" align=\"center\">4.38 min.<\/td>\n<td style=\"width: 31.1322%; height: 19.25px;\" align=\"center\">8.75 min.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"img-fluid\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNOT3425-01.jpg\" alt=\"diagram\" width=\"1900\" height=\"160\" data-uw-rm-ima-original=\"equation-article-gnot3425-01.jpg\" data-uw-rm-ima=\"ai\" title=\"-\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Use our quick-reference chart to set retention time (dead volume) for methane based on your carrier gas and column length.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[23],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[562],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-43758","post","type-post","status-publish","format-standard","hentry","category-faq","resource-type-chromatography-fundamentals"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}],"resource-type":[{"value":562,"label":"Chromatography Fundamentals"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43758","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=43758"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43758\/revisions"}],"predecessor-version":[{"id":100860,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43758\/revisions\/100860"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=43758"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=43758"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=43758"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=43758"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=43758"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=43758"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=43758"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=43758"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=43758"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}