{"id":43783,"date":"2024-07-24T00:00:00","date_gmt":"2024-07-24T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/thermal-desorption-gas-chromatography-mass-spectrometry-td-gc-ms-analysis-of-pfas-used-in-food-contact-materials\/"},"modified":"2026-04-03T15:56:13","modified_gmt":"2026-04-03T15:56:13","slug":"thermal-desorption-gas-chromatography-mass-spectrometry-td-gc-ms-analysis-of-pfas-used-in-food-contact-materials","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles-fr\/gnot4328\/thermal-desorption-gas-chromatography-mass-spectrometry-td-gc-ms-analysis-of-pfas-used-in-food-contact-materials","title":{"rendered":"Thermal Desorption \u2013 Gas Chromatography \u2013 Mass Spectrometry (TD-GC-MS) Analysis of PFAS Used in Food Contact Materials"},"content":{"rendered":"\n<p><strong>Author(s):<\/strong> Nancy Wolf<sup>1<\/sup>, Lina M\u00fcller<sup>1<\/sup>, Sarah Enge<sup>1<\/sup>, Tina Ungeth\u00fcm<sup>1<\/sup>, Thomas J. Simat<sup>1<\/sup><br>1. Chair of Food Science and Food Contact Materials, TU Dresden, Dresden<\/p>\n\n\n\n<p><strong>Published By:<\/strong> Food Additives &amp; Contaminants: Part A<\/p>\n\n\n\n<p><strong>Year of Publication:<\/strong> 2024<\/p>\n\n\n\n<p><strong>Link:<\/strong> <a href=\"https:\/\/doi.org\/10.1080\/19440049.2024.2370371\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1080\/19440049.2024.2370371<\/a><\/p>\n\n\n\n<p><strong>Abstract:<\/strong> Per- and polyfluoroalkyl substances (PFAS) are used in food contact materials (FCMs), e.g. as production aids in the fabrication of PTFE based coatings for kitchenware or as additives in paper and board. Growing concerns about the environment and health related to PFAS have led to an increasing interest in monitoring PFAS levels in FCMs as well as their migration into food. In this study, method development for the analysis of PFAS by thermal desorption \u2013 gas chromatography \u2013 mass spectrometry (TD-GC-MS) was done. In addition to fluorotelomer alcohols (FTOHs), which are the only PFAS commonly analysed by GC-MS, it was proven that perfluorocarboxylic acids (PFCAs) and per- and polyfluoroether carboxylic acids (PFECAs) as well as their thermolysis products, perfluoroethers (PFEs) and perfluoroalkenes, can be analysed by GC-MS without prior derivatization. Screening for PFCAs and FTOHs was possible by electron impact ionization (EI) using group specific SIM fragments. Confirmation of identity has been done by EI scans as well as chemical ionization (CI) SIM measurements. LODs (limits of detection) of PFCAs, FTOHs and PFECAs in the TD-GC-MS instrument were in the low pg range. Thermal degradation of PFCAs and PFECAs during TD-GC-MS measurement was investigated.<\/p>\n\n\n\n<p><strong>Acknowledgment(s):<\/strong> This analysis features Restek\u2019s Rtx-200ms column (cat.# 15653). <a href=\"https:\/\/discover.restek.com\/gnss4041\/rtx-200-gc-columns\/\" data-type=\"post\" data-id=\"43852\">Learn more about our Rtx-200 columns<\/a>.<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/15653\">                                \u8d27\u53f7\uff1a 15653                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-200ms GC Capillary Column, 30 m, 0.25 mm ID, 1.00 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/15653\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Growing concerns about the environment and health related to PFAS have led to an increasing interest in monitoring PFAS levels in FCMs as well as their migration into food. In this study, method development for the analysis of PFAS by thermal desorption \u2013 gas chromatography \u2013 mass spectrometry (TD-GC-MS) was done.<\/p>\n","protected":false},"author":65,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[462],"tags":[2782],"industries-application":[2208,2214,2216,2212],"post-badge":[],"resource-type":[568],"product-library":[2444],"resource-technique":[2315,2316,2320],"ppma_author":[722,709,743,758,757],"class_list":["post-43783","post","type-post","status-publish","format-standard","hentry","category-articles-fr","tag-pfas","industries-application-environnement","industries-application-industrie-agroalimentaire","industries-application-securite-alimentaire","industries-application-analyse-de-pfas","resource-type-third-party-peer-reviewed-publications","product-library-produits-pour-la-chromatographie-en-phase-gazeuse","resource-technique-echantillonnage-dair","resource-technique-chromatographie-en-phase-gazeuse-gc","resource-technique-spectrometrie-de-masse-ms"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"post_tag":[{"value":2782,"label":"PFAS"}],"industries-application":[{"value":2208,"label":"Environnement"},{"value":2214,"label":"Industrie Agroalimentaire"},{"value":2216,"label":"S\u00e9curit\u00e9 alimentaire"},{"value":2212,"label":"Analyse de PFAS"}],"resource-type":[{"value":568,"label":"Third-Party &amp; Peer Reviewed Publications"}],"product-library":[{"value":2444,"label":"Produits pour la chromatographie en phase gazeuse"}],"resource-technique":[{"value":2315,"label":"\u00c9chantillonnage d'air"},{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"},{"value":2320,"label":"Spectrom\u00e9trie de masse (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"SaVanna Cano","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/savanna-cano\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":462,"category_count":457,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":[{"term_id":2782,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2782,"taxonomy":"post_tag","description":"","parent":0,"count":113,"filter":"raw"}],"authors":[{"term_id":722,"user_id":0,"is_guest":1,"slug":"nancy-wolf","display_name":"Nancy Wolf","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":709,"user_id":0,"is_guest":1,"slug":"lina-muller","display_name":"Lina M\u00fcller","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":743,"user_id":0,"is_guest":1,"slug":"sarah-enge","display_name":"Sarah Enge","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":758,"user_id":0,"is_guest":1,"slug":"tina-ungethum","display_name":"Tina Ungeth\u00fcm","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":757,"user_id":0,"is_guest":1,"slug":"thomas-j-simat","display_name":"Thomas J. Simat","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43783","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=43783"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43783\/revisions"}],"predecessor-version":[{"id":92059,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43783\/revisions\/92059"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=43783"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=43783"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=43783"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=43783"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=43783"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=43783"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=43783"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=43783"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=43783"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}