{"id":43786,"date":"2025-10-03T21:40:17","date_gmt":"2025-10-03T21:40:17","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/understanding-the-origins-of-siloxane-ghost-peaks-in-gas-chromatography-en\/"},"modified":"2026-01-03T16:31:19","modified_gmt":"2026-01-03T16:31:19","slug":"understanding-the-origins-of-siloxane-ghost-peaks-in-gas-chromatography-en","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles\/gnot4432\/understanding-the-origins-of-siloxane-ghost-peaks-in-gas-chromatography-en","title":{"rendered":"Understanding the Origins of Siloxane Ghost Peaks in Gas Chromatography"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Author(s):<\/strong>&nbsp;Chris English<br>Restek Corporation&nbsp;&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Published By:<\/strong>&nbsp;LCGC&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Issue:<\/strong>&nbsp;Volume 18, Issue 06<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Year of Publication:<\/strong>&nbsp;2021<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Link:<\/strong>&nbsp;<a href=\"https:\/\/www.chromatographyonline.com\/view\/understanding-the-origins-of-siloxane-ghost-peaks-in-gas-chromatography\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.chromatographyonline.com\/view\/understanding-the-origins-of-siloxane-ghost-peaks-in-gas-chromatography<\/a>&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Abstract:<\/strong>&nbsp;Siloxane contamination can interfere with low-level analysis of target compounds whether they are discrete peaks or manifested as high background bleed. They are one of the most common types of \u201cghost peaks\u201d in gas chromatography (GC) and can come from a variety of sources such as inlet septa, columns, valves, solvents, and vial cap seals. While both column bleed and other sources of contamination contain siloxanes, the composition is different. Examining the mass spectrum and structure provides clues to the source of the contamination. This article analyzes both septa bleed and column bleed fragments and reviews best practices in reducing siloxane \u201cghost peaks\u201d, in addition to understanding the differences in composition.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Author(s):&nbsp;Chris EnglishRestek Corporation&nbsp;&nbsp;&nbsp;&nbsp; Published By:&nbsp;LCGC&nbsp; Issue:&nbsp;Volume 18, Issue 06 Year of Publication:&nbsp;2021 Link:&nbsp;https:\/\/www.chromatographyonline.com\/view\/understanding-the-origins-of-siloxane-ghost-peaks-in-gas-chromatography&nbsp; Abstract:&nbsp;Siloxane contamination can interfere with low-level analysis of target compounds whether they are discrete peaks or manifested as high background bleed. They are one of the most common types of \u201cghost peaks\u201d in gas chromatography (GC) and can come from a variety&#8230;<\/p>\n","protected":false},"author":21,"featured_media":7303,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[568],"product-library":[2480],"resource-technique":[2324],"ppma_author":[441],"class_list":["post-43786","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","resource-type-third-party-peer-reviewed-publications","product-library-gaschromatographie-produkte","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"resource-type":[{"value":568,"label":"Third-Party &amp; Peer Reviewed Publications"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNOT4432-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Chris English","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/chris-english\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/21"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=43786"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43786\/revisions"}],"predecessor-version":[{"id":79396,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/43786\/revisions\/79396"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media\/7303"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=43786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=43786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=43786"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=43786"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=43786"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=43786"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=43786"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=43786"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=43786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}