{"id":45260,"date":"2021-03-03T00:00:00","date_gmt":"2021-03-03T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analysis-of-pesticides-mycotoxins-and-cannabinoids-in-cannabis-gummies\/"},"modified":"2026-09-08T13:57:18","modified_gmt":"2026-09-08T13:57:18","slug":"analysis-of-pesticides-mycotoxins-and-cannabinoids-in-cannabis-gummies","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/application-notes\/ffan3481\/analysis-of-pesticides-mycotoxins-and-cannabinoids-in-cannabis-gummies","title":{"rendered":"Analysis of Pesticides, Mycotoxins, and Cannabinoids in Cannabis Gummies"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Abstract<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The state of California demands the analysis of pesticides, mycotoxins, and cannabinoids in all types of cannabis-derived goods [1]. For that reason, reliable workflows for the easy determination of these analytes in diverse matrices are highly desired. Gummies are a very popular cannabis edible, and their composition makes them a highly complex matrix. In this work, we describe a complete workflow for the analysis of California pesticides, mycotoxins, and cannabinoids in gummies using a single extraction procedure.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Edibles infused with cannabis or cannabidiol (CBD) are growing in popularity with cannabis consumers. In terms of testing, potency analysis of edibles is mandatory in all states where lab testing is a requisite. In addition, in the state of California, determination of contaminants, such as pesticides and mycotoxins, in edibles and other cannabis-derived goods is also a requirement. Due to the broad variety of edibles available in the market, different analytical strategies should be pursued in order to obtain reliable analytical data for all analytes of interest in all matrices. Among the various types of cannabis edibles, gummies present unique challenges for cannabis testing labs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gummies are a type of sticky matrix typically made of ingredients such as sugar, starch, pectin, and gelatin. Due to their composition, sample preparation strategies for potency testing usually include a sample solubilization step in solvents like water or DMSO or, alternatively, large volumes of solvents like methanol may be used. Following sample homogenization, cannabinoids are quantified via HPLC-UV by injecting diluted extract either directly or following a salting-out step using QuEChERS salts. As for the analysis of contaminants like pesticides and mycotoxins in gummy matrix, publicly available information is quite scarce, with only one report showing semiquantitative data for 35 pesticides using QuEChERS [2].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this work, we provide a robust workflow for the quantitative determination of the California list of pesticides, mycotoxins, and cannabinoids in gummy samples. The optimized sample preparation methodology involves sample solubilization followed by an extraction step using acidified acetonitrile, and a salting-out step using EN QuEChERS salts. For the analysis of cannabinoids and LC-amenable contaminants, a simple dilution was conducted prior to injection. Whereas, for the GC-amenable pesticides, the use of a dSPE sorbent mix including primary\/secondary amine (PSA), graphitized carbon black (GCB), and magnesium sulfate was necessary before analysis. Overall, the proposed workflow for the analysis of pesticides, mycotoxins, and cannabinoids in cannabis gummies provides satisfactory results in terms of linearity, accuracy, precision, and limits of quantitation (LOQs).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Experimental<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Sample Preparation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">After preliminary testing of various experimental parameters, the following workflow was implemented (Figure 1). Chopped gummies (1 g) were weighed into a 50 mL tube (cat.# 25846), and 5 mL of water was added. Then, the samples were vortexed vigorously until the gummy pieces were solubilized. The sample solution was then fortified with target analytes and\/or internal standards (internal standards were used only for contaminant analysis, not for potency testing) as appropriate and vortexed again for 30 seconds. Next, 5 mL of acetonitrile acidified with acetic acid (1% v:v) was added, and the samples were vortexed another 30 seconds. A pouch of European EN 15662 Q-sep QuEChERS extraction salts (cat.# 25849) was added, and the sample was vortexed again and then centrifuged for 5 minutes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For potency testing, 100 \u00b5L of the sample extract was mixed with 900 \u00b5L of 25:75 water:acetonitrile, and 2 \u00b5L were analyzed by LC-UV. For the LC-amenable contaminants, 750 \u00b5L of the sample extract was mixed with 250 \u00b5L of water, and 2 \u03bcL were analyzed by LC-MS\/MS. For the GC-amenable contaminants, 1.9 mL of extract was transferred to a Q-sep QuEChERS dSPE tube containing pre-weighed PSA, GCB, and magnesium sulfate sorbents (cat.# 26217). After vortexing and centrifuging, 500 \u03bcL of extract was mixed with 500 \u03bcL of 1% acetic acid in acetonitrile, and 1 \u03bcL was analyzed by GC-MS\/MS.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0Sample preparation procedure for the analysis of pesticides, mycotoxins, and cannabinoids in cannabis gummies.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45260_2ff333-8f .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45260_2ff333-8f\"><figure class=\"aligncenter size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1251\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3481-01-768x1251.jpg\" alt=\"\" class=\"kb-img wp-image-19834\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3481-01-768x1251.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3481-01-184x300.jpg 184w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3481-01-629x1024.jpg 629w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3481-01-943x1536.jpg 943w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3481-01-1258x2048.jpg 1258w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3481-01-scaled.jpg 1572w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Quantitation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For the analysis of pesticides and mycotoxins, calibration solutions were prepared by spiking analytes and internal standards in aliquots of extract obtained from blank gummy samples (a pooled extract was obtained by mixing extracts from various blank gummy samples). Table I shows the volume of target analyte spiking solution and internal standard mix solution that was added to each aliquot (final calibration solution volume = 3 mL). To construct calibration curves for the GC-amenable pesticides, 1.9 mL of the 3 mL calibration solutions were subjected to dSPE cleanup as described in the sample preparation section. Method accuracy and precision were evaluated by spiking homogenized gummies (after adding water and vortexing) at 10, 50, 100, and 500 ng\/g in quadruplicate (Table II), and performing the full sample preparation workflow described in the sample preparation section.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For the analysis of cannabinoids, calibration solutions were prepared at 2, 5, 10, 20, 50, 100, and 200 ppm in 75:25 acetonitrile:water. Recovery of the cannabinoids was assessed by spiking gummy samples (1 g) solubilized in water at 0.2 and 0.5 mg\/g (n=2), and then extracting them as previously described.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong>&nbsp;Preparation of calibrators for pesticides and mycotoxins analysis using aliquots of extracts collected from blank gummy samples (final volume of each calibration solution = 3 mL).<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Desired Analyte Conc. in Matrix (ng\/g)<\/strong><\/td><td><strong>Analyte Conc. in Final Extract Assuming 100% Recovery from Matrix (ng\/mL)<\/strong><\/td><td><strong>\u00b5L of Target Analyte Solution Spiked into Blank Extract<\/strong><\/td><td><strong>Analyte Conc. in Spiking Solution (ng\/mL)<\/strong><\/td><td><strong>\u00b5L of 5000 ng\/mL Internal Standard Mix Added to Blank Extract<\/strong><\/td><\/tr><tr><td>5<\/td><td>1<\/td><td>30<\/td><td>100<\/td><td>24<\/td><\/tr><tr><td>20<\/td><td>4<\/td><td>12<\/td><td>1000<\/td><td>24<\/td><\/tr><tr><td>50<\/td><td>10<\/td><td>30<\/td><td>1000<\/td><td>24<\/td><\/tr><tr><td>75<\/td><td>15<\/td><td>45<\/td><td>1000<\/td><td>24<\/td><\/tr><tr><td>150<\/td><td>30<\/td><td>90<\/td><td>1000<\/td><td>24<\/td><\/tr><tr><td>200<\/td><td>40<\/td><td>24<\/td><td>5000<\/td><td>24<\/td><\/tr><tr><td>400<\/td><td>80<\/td><td>48<\/td><td>5000<\/td><td>24<\/td><\/tr><tr><td>700<\/td><td>140<\/td><td>84<\/td><td>5000<\/td><td>24<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong>&nbsp;Fortification of mycotoxins and pesticides in gummies (1 g of sample homogenized with 5 mL of water) at different concentration levels.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Conc. in Matrix (ng\/g)<\/strong><\/td><td><strong>\u00b5L of Target Analyte Solution Spiked into Homogenized Samples in Water<\/strong><\/td><td><strong>Analyte Conc. in Spiking Solution (ng\/mL)<\/strong><\/td><td><strong>\u00b5L of 5000 ng\/mL Internal Standards Mix Added to Homogenized Samples in Water<\/strong><\/td><\/tr><tr><td>10<\/td><td>10<\/td><td>1000<\/td><td>40<\/td><\/tr><tr><td>50<\/td><td>50<\/td><td>1000<\/td><td>40<\/td><\/tr><tr><td>100<\/td><td>100<\/td><td>1000<\/td><td>40<\/td><\/tr><tr><td>500<\/td><td>100<\/td><td>5000<\/td><td>40<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Instrument Conditions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Instrumentation and conditions for the analysis of pesticides, mycotoxins, and cannabinoids in cannabis gummies are presented in Tables III, IV, and V. Ion transitions for LC-amenable and GC-amenable contaminants are presented in Tables VI and VII, respectively. Cannabinoid retention times are shown in Table VIII.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong>&nbsp;LC-MS\/MS Conditions (Pesticides and Mycotoxins).<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Column<\/strong><\/td><td colspan=\"4\">Raptor ARC-18 2.7 \u00b5m, 100 mm x 2.1 mm (cat.# 9314A12)<\/td><\/tr><tr><td><strong>Guard Column<\/strong><\/td><td colspan=\"4\">Raptor ARC-18 EXP guard column cartridge 2.7 \u00b5m, 5 x 2.1 mm (cat.# 9314A0252)<\/td><\/tr><tr><td><strong>Mobile Phase A<\/strong><\/td><td colspan=\"4\">Water, 2 mM ammonium formate, 0.1% formic acid<\/td><\/tr><tr><td><strong>Mobile Phase B<\/strong><\/td><td colspan=\"4\">Methanol, 2 mM ammonium formate, 0.1% formic acid<\/td><\/tr><tr><td rowspan=\"5\"><strong>Time Program<\/strong><\/td><td>Time (min)<\/td><td>%B<\/td><td>Time (min)<\/td><td>%B<\/td><\/tr><tr><td>0<\/td><td>5<\/td><td>10.5<\/td><td>100<\/td><\/tr><tr><td>1.5<\/td><td>65<\/td><td>10.6<\/td><td>5<\/td><\/tr><tr><td>8.5<\/td><td>95<\/td><td>12.0<\/td><td>5<\/td><\/tr><tr><td>9.5<\/td><td>100<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td><strong>Flow<\/strong><\/td><td colspan=\"4\">0.5 mL\/min<\/td><\/tr><tr><td><strong>Column Temp.<\/strong><\/td><td colspan=\"4\">40 \u00b0C<\/td><\/tr><tr><td><strong>Autosampler Temp.<\/strong><\/td><td colspan=\"4\">10 \u00b0C<\/td><\/tr><tr><td><strong>Inj. Volume<\/strong><\/td><td colspan=\"4\">2 \u03bcL<\/td><\/tr><tr><td><strong>Instrument<\/strong><\/td><td colspan=\"4\">Shimadzu LCMS-8060<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table IV:<\/strong>&nbsp;GC-MS\/MS Conditions (Pesticides).<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Instrument<\/strong><\/td><td>Thermo Trace 1310-TSQ 8000<\/td><\/tr><tr><td><strong>Column<\/strong><\/td><td>Rxi-5ms, 30 m x 0.25 mm ID x 0.25 \u00b5m, (cat.# 13423)<\/td><\/tr><tr><td><strong>Injection Mode<\/strong><\/td><td>Splitless<\/td><\/tr><tr><td><strong>Inj. Vol.<\/strong><\/td><td>1 \u00b5L<\/td><\/tr><tr><td><strong>Liner<\/strong><\/td><td>Topaz 4.0 mm ID single taper inlet liner w\/ wool (cat.# 23447)<\/td><\/tr><tr><td><strong>Inj. Temp.<\/strong><\/td><td>250 \u00b0C<\/td><\/tr><tr><td><strong>Split Flow<\/strong><\/td><td>14.0 mL\/min<\/td><\/tr><tr><td><strong>Splitless Time<\/strong><\/td><td>0.50 min<\/td><\/tr><tr><td><strong>Purge Flow<\/strong><\/td><td>5 mL\/min<\/td><\/tr><tr><td><strong>Oven<\/strong><\/td><td>90 \u00b0C (hold 1 min) to 310 \u00b0C at 25 \u00b0C\/min C (hold 10 min)<\/td><\/tr><tr><td><strong>Carrier Gas<\/strong><\/td><td>He, constant flow<\/td><\/tr><tr><td><strong>Flow Rate<\/strong><\/td><td>1.40 mL\/min<\/td><\/tr><tr><td><strong>Detector<\/strong><\/td><td>MS\/MS<\/td><\/tr><tr><td><strong>Method Type<\/strong><\/td><td>Acquisition &#8211; timed<\/td><\/tr><tr><td><strong>Ionization Mode<\/strong><\/td><td>EI<\/td><\/tr><tr><td><strong>Transfer Line Temp.<\/strong><\/td><td>290 \u00b0C<\/td><\/tr><tr><td><strong>Source Temp.<\/strong><\/td><td>330 \u00b0C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table V:<\/strong>&nbsp;HPLC-UV Conditions (Potency Using a Solvent Savings Method [3]).<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Instrument<\/strong><\/td><td>Waters ACQUITY<\/td><\/tr><tr><td><strong>Column<\/strong><\/td><td>Raptor ARC-18 2.7 \u00b5m, 150 mm x 2.1 mm (cat.# 9314A62)<\/td><\/tr><tr><td><strong>Guard column<\/strong><\/td><td>Raptor ARC-18 EXP guard column cartridge 2.7 \u00b5m, 5 x 2.1 mm (cat.# 9314A0252)<\/td><\/tr><tr><td><strong>Inj. Vol.<\/strong><\/td><td>2 \u00b5L<\/td><\/tr><tr><td><strong>Mobile phase A<\/strong><\/td><td>Water, 5 mM ammonium formate, 0.1% formic acid<\/td><\/tr><tr><td><strong>Mobile phase B<\/strong><\/td><td>Acetonitrile, 0.1% formic acid<\/td><\/tr><tr><td><strong>Gradient<\/strong><\/td><td>Isocratic, 75% B<\/td><\/tr><tr><td><strong>Flow<\/strong><\/td><td>0.4 mL\/min<\/td><\/tr><tr><td><strong>Column Temp.<\/strong><\/td><td>30 \u00b0C<\/td><\/tr><tr><td><strong>Autosampler Temp.<\/strong><\/td><td>10 \u00b0C<\/td><\/tr><tr><td><strong>Wavelength<\/strong><\/td><td>228 nm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table VI:<\/strong>&nbsp;LC-MS\/MS Transitions<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Name<\/strong><\/td>\n<td><strong>Retention Time (min)<\/strong><\/td>\n<td><strong>Precursor Ion<\/strong><\/td>\n<td><strong>Product Ion 1<\/strong><\/td>\n<td><strong>Product Ion 2<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Daminozide-D6<\/td>\n<td>0.7<\/td>\n<td>167.0<\/td>\n<td>149.3<\/td>\n<td>49.3<\/td>\n<\/tr>\n<tr>\n<td>Daminozide<\/td>\n<td>0.7<\/td>\n<td>161.1<\/td>\n<td>44.1<\/td>\n<td>143.2<\/td>\n<\/tr>\n<tr>\n<td>Acephate<\/td>\n<td>1.7<\/td>\n<td>184.0<\/td>\n<td>143.1<\/td>\n<td>95.1<\/td>\n<\/tr>\n<tr>\n<td>Oxamyl<\/td>\n<td>2.0<\/td>\n<td>237.1<\/td>\n<td>72.1<\/td>\n<td>90.1<\/td>\n<\/tr>\n<tr>\n<td>Flonicamid<\/td>\n<td>2.1<\/td>\n<td>230.1<\/td>\n<td>203.1<\/td>\n<td>174.1<\/td>\n<\/tr>\n<tr>\n<td>Methomyl<\/td>\n<td>2.1<\/td>\n<td>163.1<\/td>\n<td>88.1<\/td>\n<td>106.1<\/td>\n<\/tr>\n<tr>\n<td>Thiamethoxam<\/td>\n<td>2.1<\/td>\n<td>292.0<\/td>\n<td>211.1<\/td>\n<td>181.1<\/td>\n<\/tr>\n<tr>\n<td>Imidacloprid<\/td>\n<td>2.3<\/td>\n<td>256.1<\/td>\n<td>209.1<\/td>\n<td>175.1<\/td>\n<\/tr>\n<tr>\n<td>Mevinphos<\/td>\n<td>2.4<\/td>\n<td>225.1<\/td>\n<td>127.1<\/td>\n<td>193.2<\/td>\n<\/tr>\n<tr>\n<td>Acetamiprid<\/td>\n<td>2.4<\/td>\n<td>223.0<\/td>\n<td>126.1<\/td>\n<td>56.1<\/td>\n<\/tr>\n<tr>\n<td>Dimethoathe-D6<\/td>\n<td>2.4<\/td>\n<td>236.1<\/td>\n<td>205.1<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Dimethoate<\/td>\n<td>2.4<\/td>\n<td>230.0<\/td>\n<td>199.1<\/td>\n<td>125.1<\/td>\n<\/tr>\n<tr>\n<td>Thiacloprid<\/td>\n<td>2.5<\/td>\n<td>253.0<\/td>\n<td>126.0<\/td>\n<td>90.1<\/td>\n<\/tr>\n<tr>\n<td>Aflatoxin G2<\/td>\n<td>2.5<\/td>\n<td>331.2<\/td>\n<td>189.3<\/td>\n<td>115.2<\/td>\n<\/tr>\n<tr>\n<td>Aflatoxin G1<\/td>\n<td>2.5<\/td>\n<td>329.2<\/td>\n<td>243.2<\/td>\n<td>215.3<\/td>\n<\/tr>\n<tr>\n<td>Aldicarb<\/td>\n<td>2.6<\/td>\n<td>116.0<\/td>\n<td>89.2<\/td>\n<td>70.2<\/td>\n<\/tr>\n<tr>\n<td>Aflatoxin B2<\/td>\n<td>2.6<\/td>\n<td>315.3<\/td>\n<td>287.2<\/td>\n<td>243.3<\/td>\n<\/tr>\n<tr>\n<td>Dichlorvos<\/td>\n<td>2.7<\/td>\n<td>220.9<\/td>\n<td>109.1<\/td>\n<td>79.2<\/td>\n<\/tr>\n<tr>\n<td>Dichlorvos-D6<\/td>\n<td>2.7<\/td>\n<td>227.0<\/td>\n<td>115.1<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Aflatoxin B1<\/td>\n<td>2.7<\/td>\n<td>313.2<\/td>\n<td>241.2<\/td>\n<td>128.2<\/td>\n<\/tr>\n<tr>\n<td>Imazalil<\/td>\n<td>2.7<\/td>\n<td>297.0<\/td>\n<td>159.0<\/td>\n<td>201.0<\/td>\n<\/tr>\n<tr>\n<td>Carbofuran<\/td>\n<td>2.7<\/td>\n<td>222.1<\/td>\n<td>123.1<\/td>\n<td>165.2<\/td>\n<\/tr>\n<tr>\n<td>Propoxur<\/td>\n<td>2.7<\/td>\n<td>210.1<\/td>\n<td>111.1<\/td>\n<td>93.1<\/td>\n<\/tr>\n<tr>\n<td>Carbaryl-D7<\/td>\n<td>2.8<\/td>\n<td>209.2<\/td>\n<td>152.2<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Carbaryl<\/td>\n<td>2.8<\/td>\n<td>202.1<\/td>\n<td>145.1<\/td>\n<td>127.1<\/td>\n<\/tr>\n<tr>\n<td>Diuron-D6<\/td>\n<td>3.0<\/td>\n<td>239.1<\/td>\n<td>78.2<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Atrazine-D5<\/td>\n<td>3.0<\/td>\n<td>221.2<\/td>\n<td>179.1<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Naled<\/td>\n<td>3.1<\/td>\n<td>397.8<\/td>\n<td>127.1<\/td>\n<td>109.1<\/td>\n<\/tr>\n<tr>\n<td>Metalaxyl<\/td>\n<td>3.1<\/td>\n<td>280.2<\/td>\n<td>220.2<\/td>\n<td>192.2<\/td>\n<\/tr>\n<tr>\n<td>Spiroxamine<\/td>\n<td>3.1<\/td>\n<td>298.3<\/td>\n<td>144.2<\/td>\n<td>100.2<\/td>\n<\/tr>\n<tr>\n<td>Chlorantraniliprole<\/td>\n<td>3.2<\/td>\n<td>483.9<\/td>\n<td>452.9<\/td>\n<td>285.9<\/td>\n<\/tr>\n<tr>\n<td>Phosmet<\/td>\n<td>3.2<\/td>\n<td>318.0<\/td>\n<td>160.1<\/td>\n<td>77.2<\/td>\n<\/tr>\n<tr>\n<td>Azoxystrobin<\/td>\n<td>3.3<\/td>\n<td>404.0<\/td>\n<td>372.1<\/td>\n<td>344.1<\/td>\n<\/tr>\n<tr>\n<td>Linuron-D6<\/td>\n<td>3.3<\/td>\n<td>255.1<\/td>\n<td>160.1<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Fludioxonil*<\/td>\n<td>3.4<\/td>\n<td>247.0<\/td>\n<td>180.0<\/td>\n<td>126.0<\/td>\n<\/tr>\n<tr>\n<td>Methiocarb<\/td>\n<td>3.4<\/td>\n<td>226.1<\/td>\n<td>169.1<\/td>\n<td>121.1<\/td>\n<\/tr>\n<tr>\n<td>Dimethomorph<\/td>\n<td>3.5<\/td>\n<td>388.2<\/td>\n<td>301.2<\/td>\n<td>165.3<\/td>\n<\/tr>\n<tr>\n<td>Boscalid<\/td>\n<td>3.5<\/td>\n<td>342.9<\/td>\n<td>307.1<\/td>\n<td>140.1<\/td>\n<\/tr>\n<tr>\n<td>Paclobutrazol<\/td>\n<td>3.6<\/td>\n<td>294.3<\/td>\n<td>70.1<\/td>\n<td>125.1<\/td>\n<\/tr>\n<tr>\n<td>Malathion<\/td>\n<td>3.6<\/td>\n<td>331.0<\/td>\n<td>127.2<\/td>\n<td>285.2<\/td>\n<\/tr>\n<tr>\n<td>Myclobutanil<\/td>\n<td>3.7<\/td>\n<td>289.1<\/td>\n<td>70.1<\/td>\n<td>125.1<\/td>\n<\/tr>\n<tr>\n<td>Bifenazate<\/td>\n<td>3.7<\/td>\n<td>301.0<\/td>\n<td>198.1<\/td>\n<td>170.2<\/td>\n<\/tr>\n<tr>\n<td>Ochratoxin A<\/td>\n<td>3.8<\/td>\n<td>404.2<\/td>\n<td>239.1<\/td>\n<td>358.3<\/td>\n<\/tr>\n<tr>\n<td>Fenhexamid<\/td>\n<td>3.9<\/td>\n<td>302.1<\/td>\n<td>97.1<\/td>\n<td>55.2<\/td>\n<\/tr>\n<tr>\n<td>Spirotetramat<\/td>\n<td>4.0<\/td>\n<td>374.2<\/td>\n<td>302.1<\/td>\n<td>216.1<\/td>\n<\/tr>\n<tr>\n<td>Ethoprophos<\/td>\n<td>4.1<\/td>\n<td>243.1<\/td>\n<td>131.1<\/td>\n<td>97.1<\/td>\n<\/tr>\n<tr>\n<td>Fipronil*<\/td>\n<td>4.1<\/td>\n<td>436.8<\/td>\n<td>331.8<\/td>\n<td>251.9<\/td>\n<\/tr>\n<tr>\n<td>Fenoxycarb<\/td>\n<td>4.2<\/td>\n<td>302.1<\/td>\n<td>88.1<\/td>\n<td>116.1<\/td>\n<\/tr>\n<tr>\n<td>Kresoxim methyl<\/td>\n<td>4.4<\/td>\n<td>314.2<\/td>\n<td>267.2<\/td>\n<td>222.2<\/td>\n<\/tr>\n<tr>\n<td>Tebuconazole<\/td>\n<td>4.4<\/td>\n<td>308.1<\/td>\n<td>70.1<\/td>\n<td>125.1<\/td>\n<\/tr>\n<tr>\n<td>Diazinon-D10<\/td>\n<td>4.6<\/td>\n<td>315.2<\/td>\n<td>170.2<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Spinosad (spinosyn A)<\/td>\n<td>4.6<\/td>\n<td>732.4<\/td>\n<td>142.2<\/td>\n<td>98.1<\/td>\n<\/tr>\n<tr>\n<td>Diazinon<\/td>\n<td>4.6<\/td>\n<td>305.1<\/td>\n<td>169.2<\/td>\n<td>153.2<\/td>\n<\/tr>\n<tr>\n<td>Coumaphos<\/td>\n<td>4.7<\/td>\n<td>363.1<\/td>\n<td>227.1<\/td>\n<td>307.1<\/td>\n<\/tr>\n<tr>\n<td>Pyridaben<\/td>\n<td>4.7<\/td>\n<td>365.1<\/td>\n<td>309.2<\/td>\n<td>147.2<\/td>\n<\/tr>\n<tr>\n<td>Propiconazole<\/td>\n<td>4.7<\/td>\n<td>342.0<\/td>\n<td>159.0<\/td>\n<td>69.2<\/td>\n<\/tr>\n<tr>\n<td>Clofentezine<\/td>\n<td>4.8<\/td>\n<td>303.0<\/td>\n<td>138.1<\/td>\n<td>102.1<\/td>\n<\/tr>\n<tr>\n<td>Spinosad (spinosyn D)<\/td>\n<td>5.0<\/td>\n<td>746.5<\/td>\n<td>142.3<\/td>\n<td>98.4<\/td>\n<\/tr>\n<tr>\n<td>Spinetoram (spinosyn J)<\/td>\n<td>5.1<\/td>\n<td>748.5<\/td>\n<td>142.3<\/td>\n<td>98.3<\/td>\n<\/tr>\n<tr>\n<td>Trifloxystrobin<\/td>\n<td>5.3<\/td>\n<td>409.2<\/td>\n<td>186.1<\/td>\n<td>145.1<\/td>\n<\/tr>\n<tr>\n<td>Prallethrin<\/td>\n<td>5.3<\/td>\n<td>301.2<\/td>\n<td>123.2<\/td>\n<td>105.2<\/td>\n<\/tr>\n<tr>\n<td>Pyrethrin II<\/td>\n<td>5.5<\/td>\n<td>373.1<\/td>\n<td>161.1<\/td>\n<td>133.2<\/td>\n<\/tr>\n<tr>\n<td>Spinetoram (spinosyn L)<\/td>\n<td>5.6<\/td>\n<td>760.5<\/td>\n<td>142.2<\/td>\n<td>98.1<\/td>\n<\/tr>\n<tr>\n<td>Piperonyl butoxide<\/td>\n<td>6.0<\/td>\n<td>356.3<\/td>\n<td>177.2<\/td>\n<td>119.2<\/td>\n<\/tr>\n<tr>\n<td>Chlorpyrifos<\/td>\n<td>6.1<\/td>\n<td>349.9<\/td>\n<td>198.0<\/td>\n<td>97.1<\/td>\n<\/tr>\n<tr>\n<td>Hexythiazox<\/td>\n<td>6.2<\/td>\n<td>353.1<\/td>\n<td>228.1<\/td>\n<td>168.1<\/td>\n<\/tr>\n<tr>\n<td>Etoxazole<\/td>\n<td>6.6<\/td>\n<td>360.2<\/td>\n<td>141.1<\/td>\n<td>304.2<\/td>\n<\/tr>\n<tr>\n<td>Spiromesifen<\/td>\n<td>6.7<\/td>\n<td>273.2<\/td>\n<td>255.2<\/td>\n<td>187.2<\/td>\n<\/tr>\n<tr>\n<td>Pyrethrin I<\/td>\n<td>6.9<\/td>\n<td>329.2<\/td>\n<td>161.2<\/td>\n<td>105.2<\/td>\n<\/tr>\n<tr>\n<td>Cyfluthrin (qualifier)<\/td>\n<td>6.9<\/td>\n<td>453.1<\/td>\n<td>193.2<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Cyfluthrin<\/td>\n<td>6.9<\/td>\n<td>451.1<\/td>\n<td>191.2<\/td>\n<td>&#8211;<\/td>\n<\/tr>\n<tr>\n<td>Cypermethrin<\/td>\n<td>7.1<\/td>\n<td>433.1<\/td>\n<td>191.0<\/td>\n<td>416.0<\/td>\n<\/tr>\n<tr>\n<td>(E)-Fenpyroximate<\/td>\n<td>7.1<\/td>\n<td>422.2<\/td>\n<td>366.1<\/td>\n<td>138.1<\/td>\n<\/tr>\n<tr>\n<td>Permethrin-<em>trans<\/em><\/td>\n<td>7.6<\/td>\n<td>408.3<\/td>\n<td>183.2<\/td>\n<td>355.1<\/td>\n<\/tr>\n<tr>\n<td>Permethrin-<em>cis<\/em><\/td>\n<td>7.9<\/td>\n<td>408.3<\/td>\n<td>183.2<\/td>\n<td>355.1<\/td>\n<\/tr>\n<tr>\n<td>Avermectin B1a<\/td>\n<td>7.9<\/td>\n<td>890.5<\/td>\n<td>305.4<\/td>\n<td>567.4<\/td>\n<\/tr>\n<tr>\n<td>Etofenprox<\/td>\n<td>8.0<\/td>\n<td>394.3<\/td>\n<td>177.2<\/td>\n<td>359.3<\/td>\n<\/tr>\n<tr>\n<td>Bifenthrin<\/td>\n<td>8.2<\/td>\n<td>440.0<\/td>\n<td>181.2<\/td>\n<td>166.2<\/td>\n<\/tr>\n<tr>\n<td>Acequinocyl precursor ion 1<\/td>\n<td>9.4<\/td>\n<td>402.3<\/td>\n<td>343.2<\/td>\n<td>189.0<\/td>\n<\/tr>\n<tr>\n<td>Acequinocyl precursor ion 2<\/td>\n<td>9.4<\/td>\n<td>386.0<\/td>\n<td>344.2<\/td>\n<td>189.1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\">*Analyzed in negative mode.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table VII:<\/strong>&nbsp;GC-MS\/MS transitions.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Name<\/strong><\/td><td><strong>Retention Time (min)<\/strong><\/td><td><strong>Ion Polarity<\/strong><\/td><td><strong>Precursor Ion<\/strong><\/td><td><strong>Product Ion<\/strong><\/td><\/tr><tr><td>Atrazine-D5 (IS) (Quan)<\/td><td>6.82<\/td><td>Positive<\/td><td>220.0<\/td><td>58.0<\/td><\/tr><tr><td>Atrazine-D5 (IS) (Qual)<\/td><td>6.82<\/td><td>Positive<\/td><td>205.0<\/td><td>127.0<\/td><\/tr><tr><td>Diazinon-D10 (Quan)<\/td><td>7.01<\/td><td>Positive<\/td><td>183.0<\/td><td>139.0<\/td><\/tr><tr><td>Diazinon-D10 (Qual)<\/td><td>7.01<\/td><td>Positive<\/td><td>183.0<\/td><td>168.0<\/td><\/tr><tr><td>Quintozene (PCNB) (Quan)<\/td><td>7.03<\/td><td>Positive<\/td><td>294.9<\/td><td>236.9<\/td><\/tr><tr><td>Quintozene (PCNB) (Qual)<\/td><td>7.03<\/td><td>Positive<\/td><td>236.8<\/td><td>118.9<\/td><\/tr><tr><td>Methyl parathion (Quan)<\/td><td>7.50<\/td><td>Positive<\/td><td>263.0<\/td><td>109.0<\/td><\/tr><tr><td>Methyl parathion (Qual)<\/td><td>7.50<\/td><td>Positive<\/td><td>263.0<\/td><td>79.0<\/td><\/tr><tr><td>Captan (Quan)<\/td><td>8.37<\/td><td>Positive<\/td><td>184.0<\/td><td>149.1<\/td><\/tr><tr><td>Captan (Qual)<\/td><td>8.37<\/td><td>Positive<\/td><td>184.0<\/td><td>134.1<\/td><\/tr><tr><td><em>trans<\/em>-Chlordane (Quan)<\/td><td>8.41<\/td><td>Positive<\/td><td>271.9<\/td><td>237.0<\/td><\/tr><tr><td><em>trans<\/em>-Chlordane (Qual)<\/td><td>8.41<\/td><td>Positive<\/td><td>372.9<\/td><td>265.9<\/td><\/tr><tr><td><em>cis<\/em>-Chlordane (Quan)<\/td><td>8.53<\/td><td>Positive<\/td><td>372.9<\/td><td>265.9<\/td><\/tr><tr><td><em>cis<\/em>-Chlordane (Qual)<\/td><td>8.53<\/td><td>Positive<\/td><td>271.9<\/td><td>237.0<\/td><\/tr><tr><td>Chlorfenapyr (Quan)<\/td><td>8.80<\/td><td>Positive<\/td><td>247.1<\/td><td>227.1<\/td><\/tr><tr><td>Chlorfenapyr (Qual)<\/td><td>8.80<\/td><td>Positive<\/td><td>59.1<\/td><td>31.1<\/td><\/tr><tr><td>Cyfluthrin (Quan)<\/td><td>10.61<\/td><td>Positive<\/td><td>226.0<\/td><td>206.0<\/td><\/tr><tr><td>Cyfluthrin (Qual)<\/td><td>10.61<\/td><td>Positive<\/td><td>163.0<\/td><td>127.0<\/td><\/tr><tr><td>Cypermethrin (Quan)<\/td><td>10.87<\/td><td>Positive<\/td><td>163.0<\/td><td>127.1<\/td><\/tr><tr><td>Cypermethrin (Qual)<\/td><td>10.87<\/td><td>Positive<\/td><td>181.1<\/td><td>152.1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table VIII:<\/strong>&nbsp;Cannabinoid Retention Times.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Compound<\/strong><\/td><td><strong>Retention Time (min)<\/strong><\/td><\/tr><tr><td>Cannabidiolic acid (CBDA)<\/td><td>2.142<\/td><\/tr><tr><td>Cannabigerol (CBG)<\/td><td>2.405<\/td><\/tr><tr><td>Cannabidiol (CBD)<\/td><td>2.535<\/td><\/tr><tr><td>Cannabinol (CBN)<\/td><td>3.776<\/td><\/tr><tr><td>Delta-9-tetrahydrocannabinol (Delta-9-THC)<\/td><td>4.753<\/td><\/tr><tr><td>Tetrahydrocannabinolic acid (THCA)<\/td><td>6.279<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Results and Discussion<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Method Optimization<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The diversity of cannabis matrices and differences in the chemical characteristics of the target analytes requires multiple strategies to ensure accurate results. Analysis of pesticides, mycotoxins, and cannabinoids in cannabis gummies, as required by the state of California, needed a completely different set of experimental conditions from the ones used for brownies in our previous technical article [4]. First, we observed that dealing with pulverized gummies (grinding was conducted using dry ice and a food processor) can be extremely challenging as the matrix becomes very sticky once it gets to room temperature. For that reason, chopping gummies in small pieces was found to be a much better alternative for ease of handling when weighing the desired amount of sample.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The next challenge was finding the best approach to dissolve the matrix prior to extraction in order to obtain reliable data. Since the sample was chopped in small pieces of random size, having a homogeneous matrix was crucial to guarantee satisfactory method reproducibility. First, we evaluated the use of solvents such as acetonitrile and methanol to dissolve the gummy pieces, and to extract analytes of interest as in a simple solvent extraction. However, we found that it was very difficult to solubilize the matrix under those conditions. We also evaluated the use of DMSO for this purpose. Although all gummy pieces were easily dissolved in this solvent, daminozide was not detected in any of the extracts due to ionization suppression caused by the small percentage of DMSO that remained in the injected samples. After these tests, we concluded that hydrating the sample with 5 mL of water followed by vigorous vortexing was the best way to obtain a homogeneous sample. Subsequently, to extract all the contaminants from the matrix, 5 mL of acetonitrile acidified at 1% with acetic acid was added to the dissolved sample.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To separate the organic layer from the aqueous layer, three different Q-sep QuEChERS extraction salts were compared: AOAC (cat.# 25851), unbuffered (cat.# 25847), and EN salts (cat.# 25849). EN salts resulted in the best performance with all the compounds showing recoveries above 83% except for daminozide and its deuterated analogue, which displayed recoveries of around 25%. As for the cleanup step, the effect of four different Q-sep QuEChERS dSPE sorbent mixes (cat.#s&nbsp;26215,&nbsp;26216,&nbsp;26217,&nbsp;26242) was assessed for all the LC-MS-amenable pesticides. It was confirmed that all the mixes that contained 25 mg of PSA (cat.#s&nbsp;26215,&nbsp;26216,&nbsp;26217) led to significant losses of daminozide and ochratoxin A with only 40% of the original amount present in solution being recovered. The dSPE mix that contained MgSO4 and C18 (cat.# 26242) did not cause significant losses of pesticides; however, we decided to evaluate the suitability of using the organic extract without any further cleanup step for the quantification of LC-amenable analytes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To assess the feasibility of analyzing the extracts directly, experiments to investigate absolute matrix effects in gummy extracts without any cleanup step were conducted using the methodology proposed by Matuszweski et al. [5]. Extracts obtained from blank samples were spiked at 5, 15, and 50 ppb final concentrations, and their responses were compared to neat solvent spiked at the same concentration levels using LC-MS\/MS. At 5 ppb, 12 pesticides showed matrix effects greater than 120%, and at 15 ppb and 50 ppb, only daminozide showed significant enhancement (Table IX). Based on this and on the poor recovery of daminozide, the use of daminozide-d6 as the internal standard was crucial to obtaining reliable data.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In regard to the recoveries of GC-amenable pesticides, data corresponding to the evaluation of three dSPE sorbent mixes (cat.#s&nbsp;26215,&nbsp;26216, and&nbsp;26217) showed that, in all the cases, recoveries were above 96% when comparing the response of the cleaned extract vs. the response of the original extract. Considering the high content of sugar and pigments present in gummies extracts, the dSPE sorbent containing PSA, GCB, and magnesium sulfate (cat.# 26217) was chosen for the final sample preparation procedure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Method Verification<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Table X presents results corresponding to limits of quantitation, linearity, accuracy, and precision for the California list of pesticides and mycotoxins determined in gummy matrix. For all the contaminants analyzed via LC-MS\/MS, calibration curves were plotted using analyte\/internal standard response ratios and a weighing factor of 1\/x. For the GC-amenable analytes, only the calibration curve of PCNB was plotted using the analyte\/internal standard ratio with diazinon-d10 being chosen as internal standard. Quantification for the rest of the GC-amenable compounds was carried out with external calibration curves (area vs. spiked concentration) because this provided better results than when the internal standard was used. RSDs values below 24% were obtained for all the analytes at all the concentration levels tested. Accuracy values were within 75\u2013118%, and coefficients of determination (R<sup>2<\/sup>) were all above 0.99.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Finally, the results for cannabinoids analysis demonstrated that the extract collected for contaminants determination is also suitable for potency testing. Table XI presents data corresponding to the calibration curves prepared in solvent that were used for the quantitation of each cannabinoid. As shown in Table XII, gummy samples spiked with six cannabinoids at 0.2 mg\/g exhibited recoveries ranging from 99 to 107%, whereas samples spiked at 0.5 mg\/g showed recoveries from 99 to 106%. Representative chromatograms are presented in Figures 2\u20134.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table IX:<\/strong>&nbsp;Absolute Matrix Effects (ME) for Pesticides and Mycotoxins in Cannabis Gummies.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>\n<p>&nbsp;<\/p>\n<\/td><td>\n<p><strong>ME at 5 ppb (%)<\/strong><\/p>\n<\/td><td>\n<p><strong>RSD<\/strong><\/p>\n<\/td><td>\n<p><strong>ME at 15 ppb (%)<\/strong><\/p>\n<\/td><td>\n<p><strong>RSD<\/strong><\/p>\n<\/td><td>\n<p><strong>ME at 50 ppb (%)<\/strong><\/p>\n<\/td><td><strong>RSD<\/strong><\/td><\/tr><tr><td>\n<p>Daminozide<\/p>\n<\/td><td>\n<p>216<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>251<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>185<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Acephate<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>85<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>89<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Oxamyl<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Flonicamid<\/p>\n<\/td><td>\n<p>91<\/p>\n<\/td><td>\n<p>32<\/p>\n<\/td><td>\n<p>90<\/p>\n<\/td><td>\n<p>22<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><\/tr><tr><td>\n<p>Methomyl<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Thiamethoxam<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Imidacloprid<\/p>\n<\/td><td>\n<p>114<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>87<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><\/tr><tr><td>\n<p>Mevinphos<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Acetamiprid<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>88<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>91<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Dimethoate<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Thiacloprid<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><\/tr><tr><td>\n<p>Aflatoxin G2<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>86<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Aflatoxin G1<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>91<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><\/tr><tr><td>\n<p>Aldicarb<\/p>\n<\/td><td>\n<p>81<\/p>\n<\/td><td>\n<p>22<\/p>\n<\/td><td>\n<p>85<\/p>\n<\/td><td>\n<p>14<\/p>\n<\/td><td>\n<p>90<\/p>\n<\/td><td>\n<p>22<\/p>\n<\/td><\/tr><tr><td>\n<p>Aflatoxin B2<\/p>\n<\/td><td>\n<p>113<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>79<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><\/tr><tr><td>\n<p>Dichlorvos<\/p>\n<\/td><td>\n<p>126<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><td>\n<p>90<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><\/tr><tr><td>\n<p>Aflatoxin B1<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><\/tr><tr><td>\n<p>Imazalil<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Carbofuran<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Propoxur<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Carbaryl<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Naled<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>84<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Metalaxyl<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Spiroxamine<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Chlorantraniliprole<\/p>\n<\/td><td>\n<p>114<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>88<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Phosmet<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><\/tr><tr><td>\n<p>Azoxystrobin<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Fludioxonil<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>90<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><\/tr><tr><td>\n<p>Methiocarb<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Dimethomorph<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><\/tr><tr><td>\n<p>Boscalid<\/p>\n<\/td><td>\n<p>119<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>85<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><\/tr><tr><td>\n<p>Paclobutrazol<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>90<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><\/tr><tr><td>\n<p>Malathion<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Myclobutanil<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><\/tr><tr><td>\n<p>Bifenazate<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Ochratoxin A<\/p>\n<\/td><td>\n<p>111<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>111<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><\/tr><tr><td>\n<p>Fenhexamid<\/p>\n<\/td><td>\n<p>135<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>91<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Spirotetramat<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>87<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><\/tr><tr><td>\n<p>Ethoprophos<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Fipronil<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><\/tr><tr><td>\n<p>Fenoxycarb<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><\/tr><tr><td>\n<p>Kresoxim methyl<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>21<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>90<\/p>\n<\/td><td>\n<p>21<\/p>\n<\/td><\/tr><tr><td>\n<p>Tebuconazole<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Spinosyn A<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Diazinon<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Coumaphos<\/p>\n<\/td><td>\n<p>114<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><\/tr><tr><td>\n<p>Pyridaben<\/p>\n<\/td><td>\n<p>139<\/p>\n<\/td><td>\n<p>18<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>18<\/p>\n<\/td><\/tr><tr><td>\n<p>Propiconazole<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Clofentezine<\/p>\n<\/td><td>\n<p>126<\/p>\n<\/td><td>\n<p>14<\/p>\n<\/td><td>\n<p>87<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>14<\/p>\n<\/td><\/tr><tr><td>\n<p>Spinosyn D<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><\/tr><tr><td>\n<p>Spinosyn J<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Trifloxystrobin<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Prallethrin<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><\/tr><tr><td>\n<p>Pyrethrin II<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>23<\/p>\n<\/td><td>\n<p>82<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>23<\/p>\n<\/td><\/tr><tr><td>\n<p>Spinosyn L<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Piperonyl butoxide<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Chlorpyrifos<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>91<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><\/tr><tr><td>\n<p>Hexythiazox<\/p>\n<\/td><td>\n<p>121<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>86<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><\/tr><tr><td>\n<p>Etoxazole<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Spiromesifen<\/p>\n<\/td><td>\n<p>112<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Pyrethrin I<\/p>\n<\/td><td>\n<p>131<\/p>\n<\/td><td>\n<p>13<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>13<\/p>\n<\/td><\/tr><tr><td>\n<p>Cyfluthrin<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>80<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><\/tr><tr><td>\n<p>Cypermethrin<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>16<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>16<\/p>\n<\/td><\/tr><tr><td>\n<p>(E)-Fenpyroximate<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Permethrin-<em>trans<\/em><\/p>\n<\/td><td>\n<p>136<\/p>\n<\/td><td>\n<p>22<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>22<\/p>\n<\/td><\/tr><tr><td>\n<p>Permethrin-<em>cis<\/em><\/p>\n<\/td><td>\n<p>113<\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><\/tr><tr><td>\n<p>Avermectin B1a<\/p>\n<\/td><td>\n<p>122<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><td>\n<p>87<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><\/tr><tr><td>\n<p>Etofenprox<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Bifenthrin<\/p>\n<\/td><td>\n<p>135<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>85<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Acequinocyl<\/p>\n<\/td><td>\n<p>129<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>78<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table X:<\/strong>&nbsp;LOQ, Linearity, Accuracy, and Precision for Pesticides and Mycotoxins in Cannabis Gummies.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td rowspan=\"2\">\n<p><strong>Contaminant<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>Action level (ng\/g)<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>LOQ (ng\/g)<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>R<sup>2<\/sup><\/strong><\/p>\n<\/td><td colspan=\"2\">\n<p><strong>10 ng\/g (n=4)<\/strong><\/p>\n<\/td><td colspan=\"2\">\n<p><strong>50 ng\/g (n=4)<\/strong><\/p>\n<\/td><td colspan=\"2\">\n<p><strong>100 ng\/g (n=4)<\/strong><\/p>\n<\/td><td colspan=\"2\">\n<p><strong>500 ng\/g (n=4)<\/strong><\/p>\n<\/td><\/tr><tr><td>\n<p><strong>Accuracy (%)<\/strong><\/p>\n<\/td><td>\n<p><strong>Precision (RSD)<\/strong><\/p>\n<\/td><td>\n<p><strong>Accuracy (%)<\/strong><\/p>\n<\/td><td>\n<p><strong>Precision (RSD)<\/strong><\/p>\n<\/td><td>\n<p><strong>Accuracy (%)<\/strong><\/p>\n<\/td><td>\n<p><strong>Precision (RSD)<\/strong><\/p>\n<\/td><td>\n<p><strong>Accuracy (%)<\/strong><\/p>\n<\/td><td>\n<p><strong>Precision (RSD)<\/strong><\/p>\n<\/td><\/tr><tr><td>\n<p>Daminozide*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9999<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>114<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>114<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>116<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Acephate<\/p>\n<\/td><td>\n<p>5000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9996<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>90<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>88<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Oxamyl<\/p>\n<\/td><td>\n<p>200<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.999<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Flonicamid<\/p>\n<\/td><td>\n<p>2000<\/p>\n<\/td><td>\n<p>50<\/p>\n<\/td><td>\n<p>0.999<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>117<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Methomyl<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9989<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Thiamethoxam<\/p>\n<\/td><td>\n<p>4500<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9988<\/p>\n<\/td><td>\n<p>112<\/p>\n<\/td><td>\n<p>23<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Imidacloprid<\/p>\n<\/td><td>\n<p>3000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9985<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Mevinphos (I and II)*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9981<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Acetamiprid<\/p>\n<\/td><td>\n<p>5000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9968<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Dimethoate*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9994<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Thiacloprid*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9981<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Aflatoxin G2<\/p>\n<\/td><td>\n<p>20<sup>#<\/sup><\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9957<\/p>\n<\/td><td>\n<p>112<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><\/tr><tr><td>\n<p>Aflatoxin G1<\/p>\n<\/td><td>\n<p>20<sup>#<\/sup><\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9984<\/p>\n<\/td><td>\n<p>114<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><\/tr><tr><td>\n<p>Aldicarb*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9971<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>91<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Aflatoxin B2<\/p>\n<\/td><td>\n<p>20<sup>#<\/sup><\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9973<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>23<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><\/tr><tr><td>\n<p>Dichlorvos*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9984<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>18<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Aflatoxin B1<\/p>\n<\/td><td>\n<p>20<sup>#<\/sup><\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9978<\/p>\n<\/td><td>\n<p>113<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><\/tr><tr><td>\n<p>Imazalil*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9977<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>19<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Carbofuran*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9973<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Propoxur*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9977<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Carbaryl<\/p>\n<\/td><td>\n<p>500<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9988<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>14<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Naled<\/p>\n<\/td><td>\n<p>500<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9968<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>112<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Metalaxyl<\/p>\n<\/td><td>\n<p>15,000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9988<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Spiroxamine*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9977<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Chlorantraniliprole<\/p>\n<\/td><td>\n<p>40,000<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9971<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Phosmet<\/p>\n<\/td><td>\n<p>200<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9992<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>14<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Azoxystrobin<\/p>\n<\/td><td>\n<p>40,000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9992<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Fludioxonil<\/p>\n<\/td><td>\n<p>30,000<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9949<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>13<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Methiocarb*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9988<\/p>\n<\/td><td>\n<p>116<\/p>\n<\/td><td>\n<p>16<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Dimethomorph (I and II)<\/p>\n<\/td><td>\n<p>20,000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.999<\/p>\n<\/td><td>\n<p>75<\/p>\n<\/td><td>\n<p>14<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Boscalid<\/p>\n<\/td><td>\n<p>10,000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9964<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Paclobutrazol*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9979<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Malathion<\/p>\n<\/td><td>\n<p>5000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9989<\/p>\n<\/td><td>\n<p>117<\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><td>\n<p>112<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Myclobutanil<\/p>\n<\/td><td>\n<p>9000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9986<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>22<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Bifenazate<\/p>\n<\/td><td>\n<p>5000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9994<\/p>\n<\/td><td>\n<p>118<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Ochratoxin A<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9957<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>24<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><\/tr><tr><td>\n<p>Fenhexamid<\/p>\n<\/td><td>\n<p>10,000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9969<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>21<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Spirotetramat<\/p>\n<\/td><td>\n<p>13,000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9987<\/p>\n<\/td><td>\n<p>83<\/p>\n<\/td><td>\n<p>18<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Ethoprophos*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9985<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Fipronil*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.998<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Fenoxycarb*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9967<\/p>\n<\/td><td>\n<p>115<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Kresoxym-methyl<\/p>\n<\/td><td>\n<p>1000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9993<\/p>\n<\/td><td>\n<p>112<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Tebuconazole<\/p>\n<\/td><td>\n<p>2000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.999<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Spinosad- spinosyn A (71 %)<sup>a<\/sup><\/p>\n<\/td><td>\n<p>3000<sup>\u00a5<\/sup><\/p>\n<\/td><td>\n<p>7.1<\/p>\n<\/td><td>\n<p>0.9988<\/p>\n<\/td><td>\n<p>117<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Diazinon<\/p>\n<\/td><td>\n<p>200<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9997<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Coumaphos*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9991<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Pyridaben<\/p>\n<\/td><td>\n<p>3000<\/p>\n<\/td><td>\n<p>50<\/p>\n<\/td><td>\n<p>0.9994<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><td>\n<p>113<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Propiconazole<\/p>\n<\/td><td>\n<p>20,000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9991<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Clofentezine<\/p>\n<\/td><td>\n<p>500<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9978<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Spinosad &#8211; spinosyn D (29%)<sup>b<\/sup><\/p>\n<\/td><td>\n<p>3000<sup>\u00a5<\/sup><\/p>\n<\/td><td>\n<p>2.9<\/p>\n<\/td><td>\n<p>0.9993<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><\/tr><tr><td>\n<p>Spinetoram &#8211; spinosyn J (80%)<sup>c<\/sup><\/p>\n<\/td><td>\n<p>3000<sup>\u00a7<\/sup><\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>0.9995<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Trifloxystrobin<\/p>\n<\/td><td>\n<p>30,000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9996<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Prallethrin<\/p>\n<\/td><td>\n<p>400<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9967<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>21<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>16<\/p>\n<\/td><td>\n<p>111<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Pyrethrin II (34%)<sup>f<\/sup><\/p>\n<\/td><td>\n<p>1000<sup>\u00a3<\/sup><\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><td>\n<p>0.9977<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>112<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Spinetoram &#8211; spinosyn L (20%)<sup>d<\/sup><\/p>\n<\/td><td>\n<p>3000<sup>\u00a7<\/sup><\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>0.9993<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Piperonyl Butoxide<\/p>\n<\/td><td>\n<p>8000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9998<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Chlorpyrifos*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9995<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Hexythiazox<\/p>\n<\/td><td>\n<p>2000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9975<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Etoxazole<\/p>\n<\/td><td>\n<p>1500<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9995<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Spiromesifen<\/p>\n<\/td><td>\n<p>12,000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9992<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>111<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Pyrethrin I (54%)<sup>e<\/sup><\/p>\n<\/td><td>\n<p>1000<sup>\u00a3<\/sup><\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>0.9977<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>\n<p>Cyfluthrin<\/p>\n<\/td><td>\n<p>1000<\/p>\n<\/td><td>\n<p>50<\/p>\n<\/td><td>\n<p>0.999<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>23<\/p>\n<\/td><td>\n<p>115<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><\/tr><tr><td>\n<p>Cypermethrin<\/p>\n<\/td><td>\n<p>1000<\/p>\n<\/td><td>\n<p>50<\/p>\n<\/td><td>\n<p>0.9961<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>115<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><td>\n<p>98<\/p>\n<\/td><td>\n<p>18<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>(E)-Fenpyroximate<\/p>\n<\/td><td>\n<p>2000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9995<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Permethrin-<em>trans<\/em>&nbsp;(59%)<sup>h<\/sup><\/p>\n<\/td><td>\n<p>20,000<sup>\u00a2<\/sup><\/p>\n<\/td><td>\n<p>12<\/p>\n<\/td><td>\n<p>0.9994<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Permethrin-<em>cis<\/em>&nbsp;(41%)<sup>g<\/sup><\/p>\n<\/td><td>\n<p>20,000<sup>\u00a2<\/sup><\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>0.9996<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Avermectin B1a<\/p>\n<\/td><td>\n<p>300<\/p>\n<\/td><td>\n<p>50<\/p>\n<\/td><td>\n<p>0.9988<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>114<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Etofenprox*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9994<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Bifenthrin<\/p>\n<\/td><td>\n<p>500<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.999<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Acequinocyl<\/p>\n<\/td><td>\n<p>4000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9997<\/p>\n<\/td><td>\n<p>104<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>109<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>108<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Quintozene (PCNB) (GC)<\/p>\n<\/td><td>\n<p>200<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9966<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>14<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Methyl parathion (GC)*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9934<\/p>\n<\/td><td>\n<p>89<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>89<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>87<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>89<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Captan (GC)<\/p>\n<\/td><td>\n<p>5000<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9924<\/p>\n<\/td><td>\n<p>110<\/p>\n<\/td><td>\n<p>14<\/p>\n<\/td><td>\n<p>96<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>94<\/p>\n<\/td><td>\n<p>18<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><\/tr><tr><td>\n<p>Chlordane (GC)*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>20<\/p>\n<\/td><td>\n<p>0.9913<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>&#8211;<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>8<\/p>\n<\/td><td>\n<p>85<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><\/tr><tr><td>\n<p>Chlorfenapyr (GC)*<\/p>\n<\/td><td>\n<p>&lt;LOD<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>0.9924<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>90<\/p>\n<\/td><td>\n<p>19<\/p>\n<\/td><td>\n<p>89<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><td>\n<p>85<\/p>\n<\/td><td>\n<p>13<\/p>\n<\/td><\/tr><tr><td>\n<p>Cyfluthrin (GC)<\/p>\n<\/td><td>\n<p>1000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9935<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>10<\/p>\n<\/td><td>\n<p>92<\/p>\n<\/td><td>\n<p>18<\/p>\n<\/td><td>\n<p>91<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><td>\n<p>89<\/p>\n<\/td><td>\n<p>11<\/p>\n<\/td><\/tr><tr><td>\n<p>Cypermethrin (GC)<\/p>\n<\/td><td>\n<p>1000<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>0.9938<\/p>\n<\/td><td>\n<p>95<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><td>\n<p>83<\/p>\n<\/td><td>\n<p>17<\/p>\n<\/td><td>\n<p>97<\/p>\n<\/td><td>\n<p>15<\/p>\n<\/td><td>\n<p>93<\/p>\n<\/td><td>\n<p>9<\/p>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Category I pesticides, LOQ \u2264100 ng\/g<br><sup>a<\/sup>Spinosad- spinosyn A: Conc. 1: 7 ng\/g; Conc. 2: 35.5 ng\/g; Conc. 3: 71 ng\/g; Conc. 4: 355 ng\/g<br><sup>b<\/sup>Spinosad &#8211; spinosyn D: Conc. 1: 3 ng\/g; conc. 2: 14.5 ng\/g; Conc. 3: 29 ng\/g; Conc. 4: 145 ng\/g<br><sup>c<\/sup>Spinetoram &#8211; spinosyn J: Conc. 1: 8 ng\/g; Conc. 2: 40 ng\/g; Conc. 3: 80 ng\/g; Conc. 4: 400 ng\/g<br><sup>d<\/sup>Spinetoram &#8211; spinosyn L: Conc. 1: 2 ng\/g; Conc. 2: 10 ng\/g; Conc. 3: 20 ng\/g; Conc. 4: 100 ng\/g<br><sup>e<\/sup>Pyrethrin I: Conc. 1: 5 ng\/g; Conc. 2: 27 ng\/g; Conc. 3: 54 ng\/g; Conc. 4: 270 ng\/g<br><sup>f<\/sup>Pyrethrin II: Conc. 1: 3 ng\/g; Conc. 2: 17 ng\/g; Conc. 3: 34 ng\/g; Conc. 4: 170 ng\/g<br><sup>g<\/sup>Permethrin-<em>cis<\/em>: Conc. 1: 4 ng\/g; Conc. 2: 20.5 ng\/g; Conc. 3: 41 ng\/g; Conc. 4: 205 ng\/g<br><sup>h<\/sup>Permethrin-<em>trans<\/em>: Conc. 1: 6 ng\/g; Conc. 2: 29.5 ng\/g; Conc. 3: 59 ng\/g; Conc. 4: 295 ng\/g<br><sup>#<\/sup>Total of aflatoxin B1, B2, G1, and G2 should not exceed 20 ng\/g.<br><sup>\u00a5<\/sup>Total spinosad should not exceed 3000 ng\/g.<br><sup>\u00a7<\/sup>Total spinetoram should not exceed 3000 ng\/g.<br><sup>\u00a3<\/sup>&nbsp;Total pyrethrins should not exceed 1000 ng\/g.<br><sup>\u00a2<\/sup>Total permethrins should not exceed 20,000 ng\/g.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table XI:<\/strong>&nbsp;Linearity for Cannabinoids in Cannabis Gummies.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>\n<p><strong>Cannabinoids<\/strong><\/p>\n<\/td><td>\n<p><strong>Retention time<\/strong><\/p>\n<\/td><td>\n<p><strong>R<sup>2<\/sup><\/strong><\/p>\n<\/td><td>\n<p><strong>Equation<\/strong><\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabidiolic acid (CBDA)<\/p>\n<\/td><td>\n<p>2.142<\/p>\n<\/td><td>\n<p>0.9993<\/p>\n<\/td><td>\n<p>y = 2.08e+004x + 1.03e+003<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabigerol (CBG)<\/p>\n<\/td><td>\n<p>2.405<\/p>\n<\/td><td>\n<p>0.9981<\/p>\n<\/td><td>\n<p>y = 1.16e+004x + 1.85e+003<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabidiol (CBD)<\/p>\n<\/td><td>\n<p>2.535<\/p>\n<\/td><td>\n<p>0.9972<\/p>\n<\/td><td>\n<p>y = 1.17e+004x + 1.42e+003<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabinol (CBN)<\/p>\n<\/td><td>\n<p>3.776<\/p>\n<\/td><td>\n<p>0.9980<\/p>\n<\/td><td>\n<p>y = 2.70e+004x + 6.14e+004<\/p>\n<\/td><\/tr><tr><td>\n<p>Delta-9-tetrahydrocannabinol (Delta-9-THC)<\/p>\n<\/td><td>\n<p>4.753<\/p>\n<\/td><td>\n<p>0.9970<\/p>\n<\/td><td>\n<p>y = 1.06e+004x + 7.29e+003<\/p>\n<\/td><\/tr><tr><td>\n<p>Tetrahydrocannabinolic acid (THCA)<\/p>\n<\/td><td>\n<p>6.279<\/p>\n<\/td><td>\n<p>0.9986<\/p>\n<\/td><td>\n<p>y = 1.78e+004x &#8211; 1.28e+003<\/p>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table XII:<\/strong>&nbsp;Accuracy and Precision for Cannabinoids in Cannabis Gummies.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>\n<p><strong>Cannabinoid\/Spike Level<\/strong><\/p>\n<\/td><td colspan=\"2\">\n<p><strong>Diluted Extract Concentration (ppm)<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>Average (ppm)<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>SD<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>RSD (%)<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>Undiluted Extract Conc. (ppm)<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>Estimated Sample Concentration (mg\/g)<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>Accuracy (%)<\/strong><\/p>\n<\/td><td rowspan=\"2\">\n<p><strong>Percent Error<\/strong><\/p>\n<\/td><\/tr><tr><td>\n<p><strong>Gummy spiked at 0.2 mg\/g<\/strong><\/p>\n<\/td><td>\n<p><strong>Replicate 1<\/strong><\/p>\n<\/td><td>\n<p><strong>Replicate 2<\/strong><\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabidiolic acid (CBDA)<\/p>\n<\/td><td>\n<p>4.2<\/p>\n<\/td><td>\n<p>4.4<\/p>\n<\/td><td>\n<p>4.3<\/p>\n<\/td><td>\n<p>0.1<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>43<\/p>\n<\/td><td>\n<p>0.2<\/p>\n<\/td><td>\n<p>107<\/p>\n<\/td><td>\n<p>7<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabigerol (CBG)<\/p>\n<\/td><td>\n<p>4.0<\/p>\n<\/td><td>\n<p>3.9<\/p>\n<\/td><td>\n<p>4.0<\/p>\n<\/td><td>\n<p>0.1<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>40<\/p>\n<\/td><td>\n<p>0.2<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabidiol (CBD)<\/p>\n<\/td><td>\n<p>4.1<\/p>\n<\/td><td>\n<p>4.2<\/p>\n<\/td><td>\n<p>4.1<\/p>\n<\/td><td>\n<p>0.1<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>41<\/p>\n<\/td><td>\n<p>0.2<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabinol (CBN)<\/p>\n<\/td><td>\n<p>4.0<\/p>\n<\/td><td>\n<p>4.1<\/p>\n<\/td><td>\n<p>4.1<\/p>\n<\/td><td>\n<p>0.1<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>41<\/p>\n<\/td><td>\n<p>0.2<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Delta-9 tetrahydrocannabinol (Delta 9 THC)<\/p>\n<\/td><td>\n<p>4.0<\/p>\n<\/td><td>\n<p>4.2<\/p>\n<\/td><td>\n<p>4.1<\/p>\n<\/td><td>\n<p>0.1<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>41<\/p>\n<\/td><td>\n<p>0.2<\/p>\n<\/td><td>\n<p>103<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><\/tr><tr><td>\n<p>Tetrahydrocannabinolic acid (THCA)<\/p>\n<\/td><td>\n<p>4.1<\/p>\n<\/td><td>\n<p>4.3<\/p>\n<\/td><td>\n<p>4.2<\/p>\n<\/td><td>\n<p>0.1<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>42<\/p>\n<\/td><td>\n<p>0.2<\/p>\n<\/td><td>\n<p>105<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><\/tr><tr><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td><strong>Gummy spiked at 0.5 mg\/g<\/strong><\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>\n<p>Cannabidiolic acid (CBDA)<\/p>\n<\/td><td>\n<p>10.4<\/p>\n<\/td><td>\n<p>10.7<\/p>\n<\/td><td>\n<p>10.6<\/p>\n<\/td><td>\n<p>0.2<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>0.5<\/p>\n<\/td><td>\n<p>106<\/p>\n<\/td><td>\n<p>6<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabigerol (CBG)<\/p>\n<\/td><td>\n<p>9.5<\/p>\n<\/td><td>\n<p>10.3<\/p>\n<\/td><td>\n<p>9.9<\/p>\n<\/td><td>\n<p>0.5<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>0.5<\/p>\n<\/td><td>\n<p>99<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabidiol (CBD)<\/p>\n<\/td><td>\n<p>9.8<\/p>\n<\/td><td>\n<p>10.6<\/p>\n<\/td><td>\n<p>10.2<\/p>\n<\/td><td>\n<p>0.5<\/p>\n<\/td><td>\n<p>5<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>0.5<\/p>\n<\/td><td>\n<p>102<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><\/tr><tr><td>\n<p>Cannabinol (CBN)<\/p>\n<\/td><td>\n<p>9.8<\/p>\n<\/td><td>\n<p>10.3<\/p>\n<\/td><td>\n<p>10.0<\/p>\n<\/td><td>\n<p>0.4<\/p>\n<\/td><td>\n<p>4<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>0.5<\/p>\n<\/td><td>\n<p>100<\/p>\n<\/td><td>\n<p>0<\/p>\n<\/td><\/tr><tr><td>\n<p>Delta-9-tetrahydrocannabinol (Delta-9-THC)<\/p>\n<\/td><td>\n<p>9.9<\/p>\n<\/td><td>\n<p>10.3<\/p>\n<\/td><td>\n<p>10.1<\/p>\n<\/td><td>\n<p>0.3<\/p>\n<\/td><td>\n<p>3<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>0.5<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><tr><td>\n<p>Tetrahydrocannabinolic acid (THCA)<\/p>\n<\/td><td>\n<p>10.3<\/p>\n<\/td><td>\n<p>9.9<\/p>\n<\/td><td>\n<p>10.1<\/p>\n<\/td><td>\n<p>0.2<\/p>\n<\/td><td>\n<p>2<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>0.5<\/p>\n<\/td><td>\n<p>101<\/p>\n<\/td><td>\n<p>1<\/p>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0LC-MS\/MS chromatogram of an extract obtained from blank gummy spiked with pesticides and mycotoxins at 100 ng\/g.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0666.png\" alt=\"California Cannabis Pesticides and Mycotoxins in Gummy Edibles on Raptor ARC-18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_GN0666<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><th style=\"text-align: center;width: 75px\">Polarity<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Daminozide-d6<\/td><td class=\"oth\">0.7<\/td><td class=\"oth\">167.0<\/td><td class=\"oth\">149.3<\/td><td class=\"oth\">49.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Daminozide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1596-84-5\/Daminozide\" target=\"_blank\" rel=\"noopener\">Daminozide<\/a><\/td><td class=\"oth\">0.7<\/td><td class=\"oth\">161.1<\/td><td class=\"oth\">44.1<\/td><td class=\"oth\">143.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acephate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/30560-19-1\/Acephate\" target=\"_blank\" rel=\"noopener\">Acephate<\/a><\/td><td class=\"oth\">1.7<\/td><td class=\"oth\">184.0<\/td><td class=\"oth\">143.1<\/td><td class=\"oth\">95.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxamyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23135-22-0\/Oxamyl\" target=\"_blank\" rel=\"noopener\">Oxamyl<\/a><\/td><td class=\"oth\">2.0<\/td><td class=\"oth\">237.1<\/td><td class=\"oth\">72.1<\/td><td class=\"oth\">90.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flonicamid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/158062-67-0\/Flonicamid\" target=\"_blank\" rel=\"noopener\">Flonicamid<\/a><\/td><td class=\"oth\">2.1<\/td><td class=\"oth\">230.1<\/td><td class=\"oth\">203.1<\/td><td class=\"oth\">174.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methomyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/16752-77-5\/Methomyl\" target=\"_blank\" rel=\"noopener\">Methomyl<\/a><\/td><td class=\"oth\">2.1<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">88.1<\/td><td class=\"oth\">106.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thiamethoxam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/153719-23-4\/Thiamethoxam\" target=\"_blank\" rel=\"noopener\">Thiamethoxam<\/a><\/td><td class=\"oth\">2.1<\/td><td class=\"oth\">292.0<\/td><td class=\"oth\">211.1<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imidacloprid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/138261-41-3\/Imidacloprid\" target=\"_blank\" rel=\"noopener\">Imidacloprid<\/a><\/td><td class=\"oth\">2.3<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">209.1<\/td><td class=\"oth\">175.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mevinphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7786-34-7\/Mevinphos\" target=\"_blank\" rel=\"noopener\">Mevinphos<\/a><\/td><td class=\"oth\">2.4<\/td><td class=\"oth\">225.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetamiprid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/135410-20-7\/Acetamiprid\" target=\"_blank\" rel=\"noopener\">Acetamiprid<\/a><\/td><td class=\"oth\">2.4<\/td><td class=\"oth\">223.0<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">56.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\">Dimethoathe-d6<\/td><td class=\"oth\">2.4<\/td><td class=\"oth\">236.1<\/td><td class=\"oth\">205.1<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-51-5\/Dimethoate\" target=\"_blank\" rel=\"noopener\">Dimethoate<\/a><\/td><td class=\"oth\">2.4<\/td><td class=\"oth\">230.0<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thiacloprid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111988-49-9\/Thiacloprid\" target=\"_blank\" rel=\"noopener\">Thiacloprid<\/a><\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">253.0<\/td><td class=\"oth\">126.0<\/td><td class=\"oth\">90.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7241-98-7\/Aflatoxin G2\" target=\"_blank\" rel=\"noopener\">Aflatoxin G2<\/a><\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">331.2<\/td><td class=\"oth\">189.3<\/td><td class=\"oth\">115.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1165-39-5\/Aflatoxin G1\" target=\"_blank\" rel=\"noopener\">Aflatoxin G1<\/a><\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">329.2<\/td><td class=\"oth\">243.2<\/td><td class=\"oth\">215.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aldicarb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116-06-3\/Aldicarb\" target=\"_blank\" rel=\"noopener\">Aldicarb<\/a><\/td><td class=\"oth\">2.6<\/td><td class=\"oth\">116.0<\/td><td class=\"oth\">89.2<\/td><td class=\"oth\">70.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7220-81-7\/Aflatoxin B2\" target=\"_blank\" rel=\"noopener\">Aflatoxin B2<\/a><\/td><td class=\"oth\">2.6<\/td><td class=\"oth\">315.3<\/td><td class=\"oth\">287.2<\/td><td class=\"oth\">243.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dichlorvos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-73-7\/Dichlorvos\" target=\"_blank\" rel=\"noopener\">Dichlorvos<\/a><\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">220.9<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">79.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\">Dichlorvos-d6<\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">227.0<\/td><td class=\"oth\">115.1<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1162-65-8\/Aflatoxin B1\" target=\"_blank\" rel=\"noopener\">Aflatoxin B1<\/a><\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">313.2<\/td><td class=\"oth\">241.2<\/td><td class=\"oth\">128.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imazalil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/35554-44-0\/Imazalil\" target=\"_blank\" rel=\"noopener\">Imazalil<\/a><\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">297.0<\/td><td class=\"oth\">159.0<\/td><td class=\"oth\">201.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbofuran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1563-66-2\/Carbofuran\" target=\"_blank\" rel=\"noopener\">Carbofuran<\/a><\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">222.1<\/td><td class=\"oth\">123.1<\/td><td class=\"oth\">165.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propoxur\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/114-26-1\/Propoxur\" target=\"_blank\" rel=\"noopener\">Propoxur<\/a><\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">210.1<\/td><td class=\"oth\">111.1<\/td><td class=\"oth\">93.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbaryl-d7\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/362049-56-7\/Carbaryl-d7\" target=\"_blank\" rel=\"noopener\">Carbaryl-d7<\/a><\/td><td class=\"oth\">2.8<\/td><td class=\"oth\">209.2<\/td><td class=\"oth\">152.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbaryl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/63-25-2\/Carbaryl\" target=\"_blank\" rel=\"noopener\">Carbaryl<\/a><\/td><td class=\"oth\">2.8<\/td><td class=\"oth\">202.1<\/td><td class=\"oth\">145.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\">Diuron-d6<\/td><td class=\"oth\">3.0<\/td><td class=\"oth\">239.1<\/td><td class=\"oth\">78.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine-d5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/163165-75-1\/Atrazine-d5\" target=\"_blank\" rel=\"noopener\">Atrazine-d5<\/a><\/td><td class=\"oth\">3.0<\/td><td class=\"oth\">221.2<\/td><td class=\"oth\">179.1<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naled\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/300-76-5\/Naled\" target=\"_blank\" rel=\"noopener\">Naled<\/a><\/td><td class=\"oth\">3.1<\/td><td class=\"oth\">397.8<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metalaxyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57837-19-1\/Metalaxyl\" target=\"_blank\" rel=\"noopener\">Metalaxyl<\/a><\/td><td class=\"oth\">3.1<\/td><td class=\"oth\">280.2<\/td><td class=\"oth\">220.2<\/td><td class=\"oth\">192.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spiroxamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118134-30-8\/Spiroxamine\" target=\"_blank\" rel=\"noopener\">Spiroxamine<\/a><\/td><td class=\"oth\">3.1<\/td><td class=\"oth\">298.3<\/td><td class=\"oth\">144.2<\/td><td class=\"oth\">100.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorantraniliprole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/500008-45-7\/Chlorantraniliprole\" target=\"_blank\" rel=\"noopener\">Chlorantraniliprole<\/a><\/td><td class=\"oth\">3.2<\/td><td class=\"oth\">483.9<\/td><td class=\"oth\">452.9<\/td><td class=\"oth\">285.9<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phosmet\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/732-11-6\/Phosmet\" target=\"_blank\" rel=\"noopener\">Phosmet<\/a><\/td><td class=\"oth\">3.2<\/td><td class=\"oth\">318.0<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">77.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azoxystrobin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/131860-33-8\/Azoxystrobin\" target=\"_blank\" rel=\"noopener\">Azoxystrobin<\/a><\/td><td class=\"oth\">3.3<\/td><td class=\"oth\">404.0<\/td><td class=\"oth\">372.1<\/td><td class=\"oth\">344.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linuron-d6\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1219804-76-8\/Linuron-d6\" target=\"_blank\" rel=\"noopener\">Linuron-d6<\/a><\/td><td class=\"oth\">3.3<\/td><td class=\"oth\">255.1<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fludioxonil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/131341-86-1\/Fludioxonil\" target=\"_blank\" rel=\"noopener\">Fludioxonil<\/a><\/td><td class=\"oth\">3.4<\/td><td class=\"oth\">247.0<\/td><td class=\"oth\">180.0<\/td><td class=\"oth\">126.0<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methiocarb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2032-65-7\/Methiocarb\" target=\"_blank\" rel=\"noopener\">Methiocarb<\/a><\/td><td class=\"oth\">3.4<\/td><td class=\"oth\">226.1<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethomorph\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110488-70-5\/Dimethomorph\" target=\"_blank\" rel=\"noopener\">Dimethomorph<\/a><\/td><td class=\"oth\">3.5<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">301.2<\/td><td class=\"oth\">165.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Boscalid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/188425-85-6\/Boscalid\" target=\"_blank\" rel=\"noopener\">Boscalid<\/a><\/td><td class=\"oth\">3.5<\/td><td class=\"oth\">342.9<\/td><td class=\"oth\">307.1<\/td><td class=\"oth\">140.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Paclobutrazol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76738-62-0\/Paclobutrazol\" target=\"_blank\" rel=\"noopener\">Paclobutrazol<\/a><\/td><td class=\"oth\">3.6<\/td><td class=\"oth\">294.3<\/td><td class=\"oth\">70.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Malathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-75-5\/Malathion\" target=\"_blank\" rel=\"noopener\">Malathion<\/a><\/td><td class=\"oth\">3.6<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">127.2<\/td><td class=\"oth\">285.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Myclobutanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88671-89-0\/Myclobutanil\" target=\"_blank\" rel=\"noopener\">Myclobutanil<\/a><\/td><td class=\"oth\">3.7<\/td><td class=\"oth\">289.1<\/td><td class=\"oth\">70.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bifenazate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/149877-41-8\/Bifenazate\" target=\"_blank\" rel=\"noopener\">Bifenazate<\/a><\/td><td class=\"oth\">3.7<\/td><td class=\"oth\">301.0<\/td><td class=\"oth\">198.1<\/td><td class=\"oth\">170.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ochratoxin A\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-47-9\/Ochratoxin A\" target=\"_blank\" rel=\"noopener\">Ochratoxin A<\/a><\/td><td class=\"oth\">3.8<\/td><td class=\"oth\">404.2<\/td><td class=\"oth\">239.1<\/td><td class=\"oth\">358.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenhexamid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/126833-17-8\/Fenhexamid\" target=\"_blank\" rel=\"noopener\">Fenhexamid<\/a><\/td><td class=\"oth\">3.9<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">55.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spirotetramat\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/203313-25-1\/Spirotetramat\" target=\"_blank\" rel=\"noopener\">Spirotetramat<\/a><\/td><td class=\"oth\">4.0<\/td><td class=\"oth\">374.2<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">216.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethoprophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13194-48-4\/Ethoprophos\" target=\"_blank\" rel=\"noopener\">Ethoprophos<\/a><\/td><td class=\"oth\">4.1<\/td><td class=\"oth\">243.1<\/td><td class=\"oth\">131.1<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fipronil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120068-37-3\/Fipronil\" target=\"_blank\" rel=\"noopener\">Fipronil<\/a><\/td><td class=\"oth\">4.1<\/td><td class=\"oth\">436.8<\/td><td class=\"oth\">331.8<\/td><td class=\"oth\">251.9<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenoxycarb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72490-01-8\/Fenoxycarb\" target=\"_blank\" rel=\"noopener\">Fenoxycarb<\/a><\/td><td class=\"oth\">4.2<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">88.1<\/td><td class=\"oth\">116.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Kresoxim-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/143390-89-0\/Kresoxim-methyl\" target=\"_blank\" rel=\"noopener\">Kresoxim-methyl<\/a><\/td><td class=\"oth\">4.4<\/td><td class=\"oth\">314.2<\/td><td class=\"oth\">267.2<\/td><td class=\"oth\">222.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tebuconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107534-96-3\/Tebuconazole\" target=\"_blank\" rel=\"noopener\">Tebuconazole<\/a><\/td><td class=\"oth\">4.4<\/td><td class=\"oth\">308.1<\/td><td class=\"oth\">70.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\">Diazinon-d10 <\/td><td class=\"oth\">4.6<\/td><td class=\"oth\">315.2<\/td><td class=\"oth\">170.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spinosyn A (Spinosad)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/168316-95-8\/Spinosyn A\" target=\"_blank\" rel=\"noopener\">Spinosyn A (Spinosad)<\/a><\/td><td class=\"oth\">4.6<\/td><td class=\"oth\">732.4<\/td><td class=\"oth\">142.2<\/td><td class=\"oth\">98.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazinon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/333-41-5\/Diazinon\" target=\"_blank\" rel=\"noopener\">Diazinon<\/a><\/td><td class=\"oth\">4.6<\/td><td class=\"oth\">305.1<\/td><td class=\"oth\">169.2<\/td><td class=\"oth\">153.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Coumaphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-72-4\/Coumaphos\" target=\"_blank\" rel=\"noopener\">Coumaphos<\/a><\/td><td class=\"oth\">4.7<\/td><td class=\"oth\">363.1<\/td><td class=\"oth\">227.1<\/td><td class=\"oth\">307.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/96489-71-3\/Pyridaben\" target=\"_blank\" rel=\"noopener\">Pyridaben<\/a><\/td><td class=\"oth\">4.7<\/td><td class=\"oth\">365.1<\/td><td class=\"oth\">309.2<\/td><td class=\"oth\">147.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propiconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60207-90-1\/Propiconazole\" target=\"_blank\" rel=\"noopener\">Propiconazole<\/a><\/td><td class=\"oth\">4.7<\/td><td class=\"oth\">342.0<\/td><td class=\"oth\">159.0<\/td><td class=\"oth\">69.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clofentezine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/74115-24-5\/Clofentezine\" target=\"_blank\" rel=\"noopener\">Clofentezine<\/a><\/td><td class=\"oth\">4.8<\/td><td class=\"oth\">303.0<\/td><td class=\"oth\">138.1<\/td><td class=\"oth\">102.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spinosyn D (Spinosad)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/168316-95-8\/Spinosyn D\" target=\"_blank\" rel=\"noopener\">Spinosyn D (Spinosad)<\/a><\/td><td class=\"oth\">5.0<\/td><td class=\"oth\">746.5<\/td><td class=\"oth\">142.3<\/td><td class=\"oth\">98.4<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spinosyn J (Spinetoram)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935545-74-7\/Spinosyn J\" target=\"_blank\" rel=\"noopener\">Spinosyn J (Spinetoram)<\/a><\/td><td class=\"oth\">5.1<\/td><td class=\"oth\">748.5<\/td><td class=\"oth\">142.3<\/td><td class=\"oth\">98.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifloxystrobin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/141517-21-7\/Trifloxystrobin\" target=\"_blank\" rel=\"noopener\">Trifloxystrobin<\/a><\/td><td class=\"oth\">5.3<\/td><td class=\"oth\">409.2<\/td><td class=\"oth\">186.1<\/td><td class=\"oth\">145.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prallethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23031-36-9\/Prallethrin\" target=\"_blank\" rel=\"noopener\">Prallethrin<\/a><\/td><td class=\"oth\">5.3<\/td><td class=\"oth\">301.2<\/td><td class=\"oth\">123.2<\/td><td class=\"oth\">105.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrethrin II\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-29-9\/Pyrethrin II\" target=\"_blank\" rel=\"noopener\">Pyrethrin II<\/a><\/td><td class=\"oth\">5.5<\/td><td class=\"oth\">373.1<\/td><td class=\"oth\">161.1<\/td><td class=\"oth\">133.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spinosyn L (Spinetoram)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935545-74-7\/Spinosyn L\" target=\"_blank\" rel=\"noopener\">Spinosyn L (Spinetoram)<\/a><\/td><td class=\"oth\">5.6<\/td><td class=\"oth\">760.5<\/td><td class=\"oth\">142.2<\/td><td class=\"oth\">98.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Piperonyl butoxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-03-6\/Piperonyl butoxide\" target=\"_blank\" rel=\"noopener\">Piperonyl butoxide<\/a><\/td><td class=\"oth\">6.0<\/td><td class=\"oth\">356.3<\/td><td class=\"oth\">177.2<\/td><td class=\"oth\">119.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpyrifos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2921-88-2\/Chlorpyrifos\" target=\"_blank\" rel=\"noopener\">Chlorpyrifos<\/a><\/td><td class=\"oth\">6.1<\/td><td class=\"oth\">349.9<\/td><td class=\"oth\">198.0<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexythiazox\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78587-05-0\/Hexythiazox\" target=\"_blank\" rel=\"noopener\">Hexythiazox<\/a><\/td><td class=\"oth\">6.2<\/td><td class=\"oth\">353.1<\/td><td class=\"oth\">228.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etoxazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/153233-91-1\/Etoxazole\" target=\"_blank\" rel=\"noopener\">Etoxazole<\/a><\/td><td class=\"oth\">6.6<\/td><td class=\"oth\">360.2<\/td><td class=\"oth\">141.1<\/td><td class=\"oth\">304.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spiromesifen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/283594-90-1\/Spiromesifen\" target=\"_blank\" rel=\"noopener\">Spiromesifen<\/a><\/td><td class=\"oth\">6.7<\/td><td class=\"oth\">273.2<\/td><td class=\"oth\">255.2<\/td><td class=\"oth\">187.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrethrin I\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-21-1\/Pyrethrin I\" target=\"_blank\" rel=\"noopener\">Pyrethrin I<\/a><\/td><td class=\"oth\">6.9<\/td><td class=\"oth\">329.2<\/td><td class=\"oth\">161.2<\/td><td class=\"oth\">105.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin (qualifier)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin (qualifier)<\/a><\/td><td class=\"oth\">6.9<\/td><td class=\"oth\">453.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin<\/a><\/td><td class=\"oth\">6.9<\/td><td class=\"oth\">451.1<\/td><td class=\"oth\">191.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cypermethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52315-07-8\/Cypermethrin\" target=\"_blank\" rel=\"noopener\">Cypermethrin<\/a><\/td><td class=\"oth\">7.1<\/td><td class=\"oth\">433.1<\/td><td class=\"oth\">191.0<\/td><td class=\"oth\">416.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (E)-Fenpyroximate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111812-58-9\/(E)-Fenpyroximate\" target=\"_blank\" rel=\"noopener\">(E)-Fenpyroximate<\/a><\/td><td class=\"oth\">7.1<\/td><td class=\"oth\">422.2<\/td><td class=\"oth\">366.1<\/td><td class=\"oth\">138.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Permethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52645-53-1\/trans-Permethrin\" target=\"_blank\" rel=\"noopener\">trans-Permethrin<\/a><\/td><td class=\"oth\">7.6<\/td><td class=\"oth\">408.3<\/td><td class=\"oth\">183.2<\/td><td class=\"oth\">355.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Permethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52645-53-1\/cis-Permethrin\" target=\"_blank\" rel=\"noopener\">cis-Permethrin<\/a><\/td><td class=\"oth\">7.9<\/td><td class=\"oth\">408.3<\/td><td class=\"oth\">183.2<\/td><td class=\"oth\">355.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Avermectin B1a\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71751-41-2\/Avermectin B1a\" target=\"_blank\" rel=\"noopener\">Avermectin B1a<\/a><\/td><td class=\"oth\">7.9<\/td><td class=\"oth\">890.5<\/td><td class=\"oth\">305.4<\/td><td class=\"oth\">567.4<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etofenprox\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80844-07-1\/Etofenprox\" target=\"_blank\" rel=\"noopener\">Etofenprox<\/a><\/td><td class=\"oth\">8.0<\/td><td class=\"oth\">394.3<\/td><td class=\"oth\">177.2<\/td><td class=\"oth\">359.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bifenthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82657-04-3\/Bifenthrin\" target=\"_blank\" rel=\"noopener\">Bifenthrin<\/a><\/td><td class=\"oth\">8.2<\/td><td class=\"oth\">440.0<\/td><td class=\"oth\">181.2<\/td><td class=\"oth\">166.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acequinocyl (precursor ion 1)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57960-19-7\/Acequinocyl\" target=\"_blank\" rel=\"noopener\">Acequinocyl (precursor ion 1)<\/a><\/td><td class=\"oth\">9.4<\/td><td class=\"oth\">402.3<\/td><td class=\"oth\">343.2<\/td><td class=\"oth\">189.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acequinocyl (precursor ion 2)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57960-19-7\/Acequinocyl\" target=\"_blank\" rel=\"noopener\">Acequinocyl (precursor ion 2)<\/a><\/td><td class=\"oth\">9.4<\/td><td class=\"oth\">386.0<\/td><td class=\"oth\">344.2<\/td><td class=\"oth\">189.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor ARC-18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A12\" rel=\"noopener\">cat.# 9314A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A0252\" rel=\"noopener\">cat.# 9314A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>California pesticide standard #1 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34124\" rel=\"noopener\">cat.# 34124<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #2 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34125\" rel=\"noopener\">cat.# 34125<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #3 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34126\" rel=\"noopener\">cat.# 34126<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #4 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34127\" rel=\"noopener\">cat.# 34127<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34128\" rel=\"noopener\">cat.# 34128<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34129\" rel=\"noopener\">cat.# 34129<\/a>)<\/td><\/tr><tr><td><\/td><td>Dimethoate-d6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31988\" rel=\"noopener\">cat.# 31988<\/a>)<\/td><\/tr><tr><td><\/td><td>Dichlorvos-d6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31987\" rel=\"noopener\">cat.# 31987<\/a>)<\/td><\/tr><tr><td><\/td><td>Carbaryl-d7 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31985\" rel=\"noopener\">cat.# 31985<\/a>)<\/td><\/tr><tr><td><\/td><td>Diazinon-d10 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31986\" rel=\"noopener\">cat.# 31986<\/a>)<\/td><\/tr><tr><td><\/td><td>Atrazine-d5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31984\" rel=\"noopener\">cat.# 31984<\/a>)<\/td><\/tr><tr><td><\/td><td>Diuron-d6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31989\" rel=\"noopener\">cat.# 31989<\/a>)<\/td><\/tr><tr><td><\/td><td>Liuron-d6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31990\" rel=\"noopener\">cat.# 31990<\/a>)<\/td><\/tr><tr><td><\/td><td>Aflatoxins standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34121\" rel=\"noopener\">cat.# 34121<\/a>)<\/td><\/tr><tr><td><\/td><td>Ochratoxin A (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34122\" rel=\"noopener\">cat.# 34122<\/a>)<\/td><\/tr><tr><td><\/td><td>Compounds not present in these mixes were obtained separately.<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>75:25 Acetonitrile:water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>3.75-15 ng\/mL (Expected concentration range in extract of gummy initially spiked at 100 ng\/g.)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>2 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 2 mM ammonium formate, 0.1% formic acid  <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 2 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>1.5<\/td><td>0.5<\/td><td>35<\/td><td>65<\/td><\/tr><tr><td>8.5<\/td><td>0.5<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>9.5<\/td><td>0.5<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.5<\/td><td>0.5<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.6<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>12.0<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+\/ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Gummies were manually chopped into small pieces, and 1 g of sample was weighed in a 50 mL polypropylene tube. The sample was mixed with 5 mL of water and then vigorously vortexed until all gummy pieces were fully solubilized. The sample was fortified with pesticides and mycotoxins at 100 ng\/g. A mix of internal standards was added at 200 ng\/g. The spiked sample was further vortexed for 30 sec. 5 mL of acetonitrile acidified with 1% acetic acid was added to the sample, and this was followed by a 30 sec vortex agitation. Then, a pouch of European EN 15662 QuEChERS extraction salts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25849\" rel=\"noopener\">cat.# 25849<\/a>) was added to the sample. The sample was vortexed for 30 sec and then centrifuged for 5 min. 750 \u00b5L of organic extract was mixed with 250 \u00b5L of water. 2 \u03bcL of final extract was injected into the LC-MS\/MS system.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Want even better performance when analyzing metal-sensitive compounds? Check out Inert LC columns at <a href=\"https:\/\/www.restek.com\/inert\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a>.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34124<\/li><li>34125<\/li><li>34126<\/li><li>34127<\/li><li>34128<\/li><li>34129<\/li><li>31988<\/li><li>31987<\/li><li>31985<\/li><li>31986<\/li><li>31984<\/li><li>31989<\/li><li>31990<\/li><li>34121<\/li><li>34122<\/li><li>9314A0252<\/li><li>9314A12<\/li><li>25849<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>California<\/li><li>Cannabis<\/li><li>Edibles<\/li><li>Mycotoxins<\/li><li>Pesticides<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0666.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0GC-MS\/MS chromatogram of an extract obtained from blank gummy spiked with pesticides and mycotoxins at 100 ng\/g.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1207.png\" alt=\"GC Amenable Pesticides Regulated by California in Gummy Edibles on Rxi-5ms\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1207<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Polarity<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><th style=\"text-align: center;width: 75px\">Transition Type<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine-d5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/163165-75-1\/Atrazine-d5\" target=\"_blank\" rel=\"noopener\">Atrazine-d5<\/a><\/td><td class=\"oth\">6.82<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">220.0<\/td><td class=\"oth\">58.0<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine-d5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/163165-75-1\/Atrazine-d5\" target=\"_blank\" rel=\"noopener\">Atrazine-d5<\/a><\/td><td class=\"oth\">6.82<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">205.0<\/td><td class=\"oth\">127.0<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\">Diazinon-d10 (diethyl-d10)<\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">183.0<\/td><td class=\"oth\">139.0<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\">Diazinon-d10 (diethyl-d10)<\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">183.0<\/td><td class=\"oth\">168.0<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quintozene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Quintozene\" target=\"_blank\" rel=\"noopener\">Quintozene<\/a><\/td><td class=\"oth\">7.03<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">294.9<\/td><td class=\"oth\">236.9<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quintozene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Quintozene\" target=\"_blank\" rel=\"noopener\">Quintozene<\/a><\/td><td class=\"oth\">7.03<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">236.8<\/td><td class=\"oth\">118.9<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl parathion\" target=\"_blank\" rel=\"noopener\">Methyl parathion<\/a><\/td><td class=\"oth\">7.50<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">263.0<\/td><td class=\"oth\">109.0<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl parathion\" target=\"_blank\" rel=\"noopener\">Methyl parathion<\/a><\/td><td class=\"oth\">7.50<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">263.0<\/td><td class=\"oth\">79.0<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-06-2\/Captan\" target=\"_blank\" rel=\"noopener\">Captan<\/a><\/td><td class=\"oth\">8.37<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">184.0<\/td><td class=\"oth\">149.1<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-06-2\/Captan\" target=\"_blank\" rel=\"noopener\">Captan<\/a><\/td><td class=\"oth\">8.37<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">184.0<\/td><td class=\"oth\">134.1<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-74-2\/trans-Chlordane\" target=\"_blank\" rel=\"noopener\">trans-Chlordane<\/a><\/td><td class=\"oth\">8.41<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">271.9<\/td><td class=\"oth\">237.0<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-74-2\/trans-Chlordane\" target=\"_blank\" rel=\"noopener\">trans-Chlordane<\/a><\/td><td class=\"oth\">8.41<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">372.9<\/td><td class=\"oth\">265.9<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-71-9\/cis-Chlordane\" target=\"_blank\" rel=\"noopener\">cis-Chlordane<\/a><\/td><td class=\"oth\">8.53<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">372.9<\/td><td class=\"oth\">265.9<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-71-9\/cis-Chlordane\" target=\"_blank\" rel=\"noopener\">cis-Chlordane<\/a><\/td><td class=\"oth\">8.53<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">271.9<\/td><td class=\"oth\">237.0<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenapyr\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122453-73-0\/Chlorfenapyr\" target=\"_blank\" rel=\"noopener\">Chlorfenapyr<\/a><\/td><td class=\"oth\">8.80<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">247.1<\/td><td class=\"oth\">227.1<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenapyr\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122453-73-0\/Chlorfenapyr\" target=\"_blank\" rel=\"noopener\">Chlorfenapyr<\/a><\/td><td class=\"oth\">8.80<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">59.1<\/td><td class=\"oth\">31.1<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin<\/a><\/td><td class=\"oth\">10.61<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">226.0<\/td><td class=\"oth\">206.0<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin<\/a><\/td><td class=\"oth\">10.61<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">163.0<\/td><td class=\"oth\">127.0<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cypermethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52315-07-8\/Cypermethrin\" target=\"_blank\" rel=\"noopener\">Cypermethrin<\/a><\/td><td class=\"oth\">10.87<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">163.0<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cypermethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52315-07-8\/Cypermethrin\" target=\"_blank\" rel=\"noopener\">Cypermethrin<\/a><\/td><td class=\"oth\">10.87<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-5ms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13423\" rel=\"noopener\">cat.# 13423<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>California pesticide standard #1 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34124\" rel=\"noopener\">cat.# 34124<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #2 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34125\" rel=\"noopener\">cat.# 34125<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #3 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34126\" rel=\"noopener\">cat.# 34126<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #4 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34127\" rel=\"noopener\">cat.# 34127<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34128\" rel=\"noopener\">cat.# 34128<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34129\" rel=\"noopener\">cat.# 34129<\/a>)<\/td><\/tr><tr><td><\/td><td>Atrazine-d5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31984\" rel=\"noopener\">cat.# 31984<\/a>)<\/td><\/tr><tr><td><\/td><td>Diazinon-d10 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31986\" rel=\"noopener\">cat.# 31986<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>2.5-10 ng\/mL Expected concentration range in extract after extracting from gummy fortified at 100 ng\/g (final extract was diluted in half with acetonitrile).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L splitless<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23447\" rel=\"noopener\">cat.# 23447<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Purge Flow:<\/th><td>5 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>90 &#176;C (hold 1 min) to 310 &#176;C at 25 &#176;C\/min (hold 10 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.4 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>290 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Gummies were manually chopped into small pieces, and 1 g of sample was weighed in a 50 mL polypropylene tube. The sample was mixed with 5 mL of water and then vigorously vortexed until all gummy pieces were fully solubilized. The sample was fortified with pesticides and mycotoxins at 100 ng\/g. A mix of internal standards was added at 200 ng\/g. The spiked sample was further vortexed for 30 sec. 5 mL of acetonitrile acidified with 1% acetic acid was added to the sample, and this was followed by 30 sec vortex agitation. Then, a pouch of European EN 15662 QuEChERS extraction salts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25849\" rel=\"noopener\">cat.# 25849<\/a>) was added to the sample. The sample was vortexed for 30 sec and then centrifuged for 5 min. 1.9 mL of supernatant was transferred to a Q-sep QuEChERS dSPE tube containing pre-weighed magnesium sulfate, PSA, and GCB (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/26217\" rel=\"noopener\">cat.# 26217<\/a>). After vortexing and centrifuging, 500 \u03bcL of extract was mixed with 500 \u03bcL of acidified acetonitrile. 1 \u03bcL of final extract was injected into the GC-MS\/MS system.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34124<\/li><li>34125<\/li><li>34126<\/li><li>34127<\/li><li>34128<\/li><li>34129<\/li><li>31984<\/li><li>31986<\/li><li>13423<\/li><li>23447<\/li><li>25849<\/li><li>26217<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>California<\/li><li>Cannabis<\/li><li>Pesticides<\/li><li>QuEChERS<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1207.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong>\u00a0HPLC-UV chromatogram of an extract obtained from blank gummy spiked with six cannabinoids at 0.2 mg\/g.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0667.png\" alt=\"Cannabinoids in Gummy Edibles on Raptor ARC-18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_GN0667<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">mg\/g*<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cannabidiolic acid (CBDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1244-58-2\/Cannabidiolic acid\" target=\"_blank\" rel=\"noopener\">Cannabidiolic acid (CBDA)<\/a><\/td><td class=\"oth\">2.142<\/td><td class=\"oth\">0.2<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cannabigerol (CBG)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/25654-31-3\/Cannabigerol\" target=\"_blank\" rel=\"noopener\">Cannabigerol (CBG)<\/a><\/td><td class=\"oth\">2.405<\/td><td class=\"oth\">0.2<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cannabidiol (CBD)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13956-29-1\/Cannabidiol\" target=\"_blank\" rel=\"noopener\">Cannabidiol (CBD)<\/a><\/td><td class=\"oth\">2.535<\/td><td class=\"oth\">0.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cannabinol (CBN)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/521-35-7\/Cannabinol\" target=\"_blank\" rel=\"noopener\">Cannabinol (CBN)<\/a><\/td><td class=\"oth\">3.776<\/td><td class=\"oth\">0.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-Tetrahydrocannabinol (\u03949-THC)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-Tetrahydrocannabinol\" target=\"_blank\" rel=\"noopener\">\u03949-Tetrahydrocannabinol (\u03949-THC)<\/a><\/td><td class=\"oth\">4.753<\/td><td class=\"oth\">0.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetrahydrocannabinolic acid A (THCA-A)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23978-85-0\/Tetrahydrocannabinolic acid A\" target=\"_blank\" rel=\"noopener\">Tetrahydrocannabinolic acid A (THCA-A)<\/a><\/td><td class=\"oth\">6.279<\/td><td class=\"oth\">0.2<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">*Extract from a gummy sample initially spiked at 0.2 mg\/g.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor ARC-18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A62\" rel=\"noopener\">cat.# 9314A62<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>150 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A0252\" rel=\"noopener\">cat.# 9314A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>Cannabinoids standard  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34014\" rel=\"noopener\">cat.# 34014<\/a>)<\/td><\/tr><tr><td><\/td><td>Cannabigerol (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34091\" rel=\"noopener\">cat.# 34091<\/a>)<\/td><\/tr><tr><td><\/td><td>d9-Tetrahydrocannabinol  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34067\" rel=\"noopener\">cat.# 34067<\/a>)<\/td><\/tr><tr><td><\/td><td>d9-Tetrahydrocannabinolic acid A  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34111\" rel=\"noopener\">cat.# 34111<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>75:25 Acetonitrile:water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>  Expected concentration of 4 ppm in final extract from gummy initially spiked at 0.2 mg\/g.<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>2 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 5 mM ammonium formate, 0.1% formic acid  <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Acetonitrile, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>25<\/td><td>75<\/td><\/tr><tr><td>10.00<\/td><td>0.4<\/td><td>25<\/td><td>75<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>UV\/Vis @ 228 nm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Gummies were manually chopped into small pieces, and 1 g of sample was weighed in a 50 mL polypropylene tube. The sample was mixed with 5 mL of water and then vigorously vortexed until all gummy pieces were fully solubilized. The sample was fortified with cannabinoids at 0.2 mg\/g. The spiked sample was further vortexed for 30 sec. 5 mL of acetonitrile acidified with 1% acetic acid was added to the sample, and this was followed by 30 sec vortex agitation. Then, a pouch of European EN 15662 QuEChERS extraction salts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25849\" rel=\"noopener\">cat.# 25849<\/a>) was added to the sample. The sample was vortexed for 30 sec and then centrifuged for 5 min. 100 \u00b5L of organic extract was mixed with 900 \u00b5L of 75:25 acetonitrile:water. 2 \u00b5L of final extract was injected into the HPLC-UV system.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34014<\/li><li>34091<\/li><li>34067<\/li><li>34111<\/li><li>9314A0252<\/li><li>9314A62<\/li><li>25849<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Edibles<\/li><li>Gummy<\/li><li>Potency<\/li><li>QuEChERs<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0667.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An easy and effective workflow for the analysis of pesticides, mycotoxins, and cannabinoids in cannabis gummies was developed. Sample preparation conditions involved matrix homogenization of gummy pieces with water, extraction of analytes using acidified acetonitrile followed by a salting-out step using Q-sep QuEChERS extraction salts; extract dilution (for LC-MS\/MS amenable contaminants and cannabinoids); and dSPE cleanup using magnesium sulfate, PSA, and GCB (for GC-MS\/MS amenable pesticides). Satisfactory results in terms of LOQ, linearity, accuracy, and precision were obtained for all the target contaminants. In addition, our data demonstrated that the proposed methodology is suitable for potency testing with accuracy values ranging from 99 to 107% for the six cannabinoids listed in the cannabis regulations of the state of California. Overall, the presented workflow streamlines work for cannabis testing labs by enabling the satisfactory quantitation of multiple analyte classes in gummy samples using a single extract.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Analysis of the California List of Pesticides and Mycotoxins in Edibles\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/-_ljDoWhE4o?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\" style=\"background-color:#e4f7fa\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading has-text-color has-link-color wp-elements-1489b0bd8c7fa6a213f7f4f1cf134d8f\" style=\"color:#02366d\">Want even better performance when analyzing mycotoxins and other metal-sensitive compounds?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Learn more at&nbsp;<a href=\"https:\/\/www.restek.com\/articles\/accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"123\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02.png\" alt=\"\" class=\"wp-image-29764\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02.png 400w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02-300x92.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">References<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Text of Regulations, Bureau of Cannabis Control, California Code of Regulations,&nbsp;<a href=\"https:\/\/cannabis.ca.gov\/wp-content\/uploads\/sites\/13\/2019\/01\/Order-of-Adoption-Clean-Version-of-Text.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/cannabis.ca.gov\/wp-content\/uploads\/sites\/13\/2019\/01\/Order-of-Adoption-Clean-Version-of-Text.pdf<\/a>, (accessed 8 November 2019).<\/li>\n\n\n\n<li>X. Wang, D. Mackowsky, J. Searfoss, M. J. Telepchak, Determination of cannabinoid content and pesticide residues in cannabis edibles and beverages, Cannabis Sci. and Tech. (2018).&nbsp;<a href=\"https:\/\/www.cannabissciencetech.com\/view\/determination-cannabinoid-content-and-pesticide-residues-cannabis-edibles-and-beverages\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.cannabissciencetech.com\/view\/determination-cannabinoid-content-and-pesticide-residues-cannabis-edibles-and-beverages<\/a>.<\/li>\n\n\n\n<li>Fast, low-solvent analysis of cannabinoids increases lab productivity and decreases solvent costs, Restek Corporation.&nbsp;<a href=\"https:\/\/discover.restek.com\/FFFA3123\/fast-low-solvent-analysis-of-cannabinoids-increases-lab-productivity-and-decreases-solvent-costs\/\" data-type=\"post\" data-id=\"43558\">https:\/\/www.restek.com\/articles\/fast-low-solvent-analysis-of-cannabinoids-increases-lab-productivity-and-decreases-solvent-costs<\/a>&nbsp;(accessed 22 January 2021).<\/li>\n\n\n\n<li>N. Reyes-Garces, C. Myers, Analysis of pesticides and mycotoxins cannabis brownies, Restek Corporation.&nbsp;<a href=\"https:\/\/discover.restek.com\/FFAN3149\/analysis-of-pesticides-and-mycotoxins-in-cannabis-brownies\/\" data-type=\"post\" data-id=\"45258\">https:\/\/www.restek.com\/articles\/analysis-of-pesticides-and-mycotoxins-in-cannabis-brownies<\/a>&nbsp;(accessed 3 December 2020).<\/li>\n\n\n\n<li>B. K. Matuszewski, M. L. Constanzer, C. M. Chavez-Eng, Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC\u2212MS\/MS, Anal. Chem. 75 (2003) 3019\u20133030.&nbsp;<a href=\"https:\/\/pubs.acs.org\/doi\/10.1021\/ac020361s\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/pubs.acs.org\/doi\/10.1021\/ac020361s<\/a><\/li>\n<\/ol>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25846\">                                \u8d27\u53f7\uff1a 25846                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Empty Centrifuge Tubes, 50 mL, Polypropylene w\/Cap, 50-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25846\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25849\">                                \u8d27\u53f7\uff1a 25849                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS Extraction Salt Packets Only (EN), 4 g MgSO4, 1 g NaCl, 1 g TSCD, 0.5 g DHS, 50 Packets<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25849\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26217\">                                \u8d27\u53f7\uff1a 26217                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS dSPE 2 mL Centrifuge Tube, Contains 150 mg MgSO4, 25 mg PSA, 2.5 mg GCB, 100 Tubes<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26217\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A12\">                                \u8d27\u53f7\uff1a 9314A12                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor ARC-18, 2.7 \u00b5m, 100 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A12\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A0252\">                                \u8d27\u53f7\uff1a 9314A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor ARC-18 EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 2.1 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A0252\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13423\">                                \u8d27\u53f7\uff1a 13423                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-5ms GC Capillary Column, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13423\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23447\">                                \u8d27\u53f7\uff1a 23447                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Thermo TRACE 1300\/1310, 1600\/1610 GCs w\/SSL inlets, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23447\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25851\">                                \u8d27\u53f7\uff1a 25851                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS Extraction Salt Packets Only (AOAC), 6 g MgSO4, 1.5 g NaOAc, 50 Packets<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25851\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25847\">                                \u8d27\u53f7\uff1a 25847                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS Extraction Salt Packets Only (Original), 4 g MgSO4, 1 g NaCl, 50 Packets<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25847\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26215\">                                \u8d27\u53f7\uff1a 26215                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS dSPE 2 mL Centrifuge Tube, Contains 150 mg MgSO4, 25 mg PSA, 100 Tubes<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26215\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26216\">                                \u8d27\u53f7\uff1a 26216                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS dSPE 2 mL Centrifuge Tube, Contains 150 mg MgSO4, 25 mg PSA, 25 mg C18-EC, 100 Tubes<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26216\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26242\">                                \u8d27\u53f7\uff1a 26242                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS dSPE 2 mL Centrifuge Tube, Contains 150 mg MgSO4, 50 mg C18-EC, 100 Tubes<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26242\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In this application note, we present an easy, effective workflow for the analysis pesticides, mycotoxins, and cannabinoids in cannabis gummies. This method streamlines testing by allowing quantitation of multiple analyte classes from a single sample extract.<\/p>\n","protected":false},"author":89,"featured_media":6841,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[13],"tags":[],"industries-application":[2149,2167,2169,2151],"post-badge":[],"resource-type":[],"product-library":[2371,2372,2380,2384,2386,2391,2373,2399,2400,2374,2375],"resource-technique":[2294,2299,2302,2303],"ppma_author":[603],"class_list":["post-45260","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","industries-application-cannabis","industries-application-food-beverage","industries-application-food-safety","industries-application-medical-or-recreational-cannabis","product-library-air-gas-sampling-products","product-library-gas-chromatography-products","product-library-gas-standards-accessories","product-library-gc-columns","product-library-inlet-supplies","product-library-lc-columns","product-library-liquid-chromatography-products","product-library-liquid-reference-standards","product-library-quechers-products","product-library-reference-standard-products","product-library-sample-preparation-products","resource-technique-gas-chromatography-gc","resource-technique-liquid-chromatography","resource-technique-ms-ms","resource-technique-quechers"],"acf":[],"taxonomy_info":{"category":[{"value":13,"label":"Application Notes"}],"industries-application":[{"value":2149,"label":"Cannabis"},{"value":2167,"label":"Food &amp; Beverage"},{"value":2169,"label":"Food Safety"},{"value":2151,"label":"Medical or Recreational Cannabis"}],"product-library":[{"value":2371,"label":"Air &amp; Gas Sampling Products"},{"value":2372,"label":"Gas Chromatography Products"},{"value":2380,"label":"Gas Standards &amp; Accessories"},{"value":2384,"label":"GC Columns"},{"value":2386,"label":"Inlet Supplies"},{"value":2391,"label":"LC Columns"},{"value":2373,"label":"Liquid Chromatography Products"},{"value":2399,"label":"Liquid Reference Standards"},{"value":2400,"label":"QuEChERS Products"},{"value":2374,"label":"Reference Standard Products"},{"value":2375,"label":"Sample Preparation Products"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2299,"label":"Liquid Chromatography"},{"value":2302,"label":"MS\/MS"},{"value":2303,"label":"QuEChERS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FFAN3481-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Travis Prebble","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/travis-prebble\/"},"comment_info":0,"category_info":[{"term_id":13,"name":"Application Notes","slug":"application-notes","term_group":0,"term_taxonomy_id":13,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":13,"category_count":88,"category_description":"","cat_name":"Application Notes","category_nicename":"application-notes","category_parent":0}],"tag_info":false,"authors":[{"term_id":603,"user_id":0,"is_guest":1,"slug":"nathaly-reyes-garces-phd","display_name":"Nathaly Reyes-Garc\u00e9s, PhD","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Nathaly","last_name":"Reyes-Garc\u00e9s","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45260","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/89"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=45260"}],"version-history":[{"count":23,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45260\/revisions"}],"predecessor-version":[{"id":102805,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45260\/revisions\/102805"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media\/6841"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=45260"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=45260"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=45260"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=45260"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=45260"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=45260"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=45260"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=45260"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=45260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}