{"id":45261,"date":"2025-10-08T17:55:23","date_gmt":"2025-10-08T17:55:23","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analysis-of-pfas-in-milk-by-lc-ms-ms\/"},"modified":"2026-07-30T15:33:13","modified_gmt":"2026-07-30T15:33:13","slug":"analysis-of-pfas-in-milk-by-lc-ms-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/application-notes\/fsan4338\/analysis-of-pfas-in-milk-by-lc-ms-ms","title":{"rendered":"Analysis of PFAS in Milk by LC-MS\/MS"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Abstract<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The ubiquitous use of per- and polyfluoroalkyl substances (PFAS) in everyday products has resulted in the accumulation of these compounds in the environment. Due to the prevalence of these compounds in environmental sources, such as water and soil, they are finding avenues into food commodities meant for human consumption. Dairy milk is one such commodity that can be impacted by environmental contaminants, such as PFAS, so it is important to implement extensive, robust, and accurate testing. In this work, a sensitive and reliable method was developed for the analysis of PFAS in milk by LC-MS\/MS at levels as low as 0.01 \u00b5g\/kg.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per- and polyfluoroalkyl substances (PFAS) are a class of manufactured organic compounds that are used in a wide array of applications and products. The carbon-fluorine bond is very stable resulting in compounds that do not readily degrade in the environment. As such, these compounds have been detected in drinking water, soil, wastewater, food commodities, and biological matrices. There are several potential adverse health effects associated with exposure to PFAS. These include increased cholesterol levels, decreased birth weight, lower antibody response to vaccines, kidney and testicular cancer, pregnancy-induced hypertension (preeclampsia), and changes in liver enzymes [1]. Since food sources have been identified as one of the avenues of exposure to PFAS, it is important to have robust, reliable, and sensitive methods to monitor these compounds in foods intended for human consumption.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">More than six billion people around the world consume dairy milk and milk products [2] so it is imperative to monitor PFAS contamination in these products. The European Food Safety Authority (EFSA) has assessed four PFAS that make up half of the lower bound exposure: perfluorooctane sulfonic acid (PFOS); perfluorooctanoic acid (PFOA); perfluorohexane sulfonic acid (PFHxS); and perfluorononaoic acid (PFNA). Toddlers and children were found to have two-fold higher exposure [3], and this could potentially be from their consumption of milk and other related food items. The EFSA recommends limiting exposure to these four PFAS to no more than 4.4 nanograms per kilogram of body weight per week [3]. In the United States, Maine Department of Agriculture, Conservation, and Forestry (DACF) established an action threshold for PFOS in milk at 210 parts per trillion [4].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this work, a method was developed for the analysis of PFAS in milk by LC-MS\/MS, including the four PFAS assessed by the EFSA and 24 other compounds included in the European Union Reference Laboratory for Halogenated POPs (persistent organic pollutants) in Feed and Food guidance document. This guidance document outlines required limits of quantitation for the four PFAS analytes identified by EFSA in milk to be as low as \u22640.01 \u00b5g\/kg [5]. This target LOQ was used in these experiments and applied to all 28 PFAS. One potential complication of this analysis is the presence of coextractables, such as bile acids. Bile acids tauroursodeoxycholic acid (TUDCA); taurochenodeoxycholic acid (TCDCA); and taurodeoxycholic acid (TDCA) can be present in high concentrations in samples of biological origin and share the same mass transition as PFOS. To accurately quantify PFOS, the bile acids need to either be removed from the sample during sample preparation or separated from PFOS chromatographically. In this application, a workflow was developed for the analysis of 28 PFAS in milk. To prepare samples, a QuEChERS approach coupled with dSPE was implemented. This workflow returned exceptional results for analysis of the four PFAS assessed by the EFSA and showed excellent method accuracy and precision for most target compounds.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Experimental<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Chromatographic Method<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">LC-MS\/MS analysis of PFAS in milk was performed on a Waters ACQUITY Premier system coupled with a Waters XEVO TQ Absolute triple quadrupole mass spectrometer. Note that a PFAS delay column was installed between the mixer and injector to prevent any potential PFAS contamination upstream of the injector from coeluting with PFAS in the samples. The method conditions are as follows:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Columns:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Analytical column: Force C18, 50 mm x 2.1 mm, 3 \u00b5m (cat.# 9634352)<\/li>\n\n\n\n<li>Guard column: Force C18 EXP, 5 mm x 2.1 mm (cat.# 963450252)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS delay column, 50 mm x 2.1 mm, 5 \u00b5m (cat.# 27854)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Injection volume: 5 \u00b5L<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mobile phase A: Water, 5 mM ammonium acetate<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mobile phase B: Methanol:acetonitrile (50:50)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Flow rate: 0.6 mL\/min<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperature: 50 \u00b0C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gradient:&nbsp;&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Time (min)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>%B<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">40<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">9.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">70<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">9.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">95<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">10.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">100<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">11.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">100<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">11.01<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">13.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Ion mode: Negative ESI<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mode: Scheduled MRM<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sample and Standard Preparation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">All products and solvents were tested for PFAS contamination prior to use. Milk samples were obtained locally and included reduced-fat milk (Sample 1); fat-free milk (Sample 2); and low-fat milk (Sample 3). Ten gram samples of milk were weighed into 50 mL centrifuge tubes (cat.# 25846) and fortified at 0.01 or 0.05 \u03bcg\/kg. Isotopically labeled internal standards were spiked into the sample at 0.1 \u00b5g\/kg and briefly vortexed. Acetonitrile (10 mL), formic acid (150 \u03bcL), and a Q-sep QuEChERS extraction salt packet (cat.# 25847) were added to the sample and vortexed for approximately 30 seconds. The samples were transferred to a shaker table and shaken for 10 minutes. The samples were then centrifuged for 5 minutes at 4200 rpm. The supernatant was aliquoted into a Q-sep QuEChERS dSPE 15 mL centrifuge tube containing 900 mg MgSO4, 300 mg PSA, 150 mg GCB (cat.# 26126) and vortexed for approximately 30 seconds followed by centrifugation for 5 minutes at 4200 rpm. The supernatant was aliquoted (6 mL) into clean 15 mL centrifuge tubes and dried down at 35 \u00b0C for 90 minutes using a blowdown evaporator. The samples were reconstituted in methanol:water (60:40) (400 \u03bcL), vortexed for approximately 30 seconds, and centrifuged for 5 minutes at 4200 rpm. The supernatant was aliquoted into a polypropylene vial (cat.# 23243) and capped with a polyethylene screw cap (cat.# 23244) and 5 \u03bcL was injected for analysis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The working calibration standards were prepared using Restek\u2019s PFAS 28 calibration standard (cat.# 30734), and the standards for other PFAS were obtained separately. The standards were aliquoted into polypropylene LC vials and diluted in 60:40 methanol:water to a concentration range of 0.03\u201350 ng\/mL. Each calibration curve included seven or eight concentration levels depending on analyte sensitivity. Internal standards were spiked in the calibration standards at 1.5 ng\/mL. Solvent calibration using isotope dilution was performed for quantitation. The mass transitions and the isotopically labeled internal standards that were used for each analyte are shown in Table I.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> Precursor Ions, Product Ions, and Isotopically Labeled Internal Standards Used for the Analysis of PFAS in Milk by LC-MS\/MS<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-background has-fixed-layout\" style=\"background-color:#ced4d9;border-width:1px\"><thead><tr><th><strong>Compound<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Precursor 1<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Product 1<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Precursor 2<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Product 2<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Internal Standard<\/strong><\/th><\/tr><\/thead><tbody><tr><td>PFBA<\/td><td class=\"has-text-align-center\" data-align=\"center\">212.94<\/td><td class=\"has-text-align-center\" data-align=\"center\">168.89<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><td class=\"has-text-align-center\" data-align=\"center\">M4PFBA<\/td><\/tr><tr><td>PFPeA<\/td><td class=\"has-text-align-center\" data-align=\"center\">262.93<\/td><td class=\"has-text-align-center\" data-align=\"center\">218.89<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><td class=\"has-text-align-center\" data-align=\"center\">NA<\/td><td class=\"has-text-align-center\" data-align=\"center\">M5PFPeA<\/td><\/tr><tr><td>PFHxA<\/td><td class=\"has-text-align-center\" data-align=\"center\">313.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">119.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">313.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">268.88<\/td><td class=\"has-text-align-center\" data-align=\"center\">M5PFHxA<\/td><\/tr><tr><td>PFHpA<\/td><td class=\"has-text-align-center\" data-align=\"center\">363.16<\/td><td class=\"has-text-align-center\" data-align=\"center\">169.06<\/td><td class=\"has-text-align-center\" data-align=\"center\">363.16<\/td><td class=\"has-text-align-center\" data-align=\"center\">319.09<\/td><td class=\"has-text-align-center\" data-align=\"center\">M4PFHpA<\/td><\/tr><tr><td>PFOA<\/td><td class=\"has-text-align-center\" data-align=\"center\">413.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">168.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">413.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">368.96<\/td><td class=\"has-text-align-center\" data-align=\"center\">M8PFOA<\/td><\/tr><tr><td>PFNA<\/td><td class=\"has-text-align-center\" data-align=\"center\">463.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">219.02<\/td><td class=\"has-text-align-center\" data-align=\"center\">463.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">419.01<\/td><td class=\"has-text-align-center\" data-align=\"center\">M9PFNA<\/td><\/tr><tr><td>PFDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">513.17<\/td><td class=\"has-text-align-center\" data-align=\"center\">219.06<\/td><td class=\"has-text-align-center\" data-align=\"center\">513.17<\/td><td class=\"has-text-align-center\" data-align=\"center\">469.16<\/td><td class=\"has-text-align-center\" data-align=\"center\">M6PFDA<\/td><\/tr><tr><td>PFUnDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">562.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">268.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">562.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">518.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">M7-PFUnDA<\/td><\/tr><tr><td>PFDoA<\/td><td class=\"has-text-align-center\" data-align=\"center\">612.52<\/td><td class=\"has-text-align-center\" data-align=\"center\">318.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">612.52<\/td><td class=\"has-text-align-center\" data-align=\"center\">568.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2-PFDoA<\/td><\/tr><tr><td>PFTrDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">662.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">168.87<\/td><td class=\"has-text-align-center\" data-align=\"center\">662.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">618.74<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2-PFTeDA<\/td><\/tr><tr><td>PFTeDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">712.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">168.87<\/td><td class=\"has-text-align-center\" data-align=\"center\">712.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">668.74<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2-PFTeDA<\/td><\/tr><tr><td>PFBS<\/td><td class=\"has-text-align-center\" data-align=\"center\">298.97<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.97<\/td><td class=\"has-text-align-center\" data-align=\"center\">298.97<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.89<\/td><td class=\"has-text-align-center\" data-align=\"center\">M3PFBS<\/td><\/tr><tr><td>PFPeS<\/td><td class=\"has-text-align-center\" data-align=\"center\">349.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.98<\/td><td class=\"has-text-align-center\" data-align=\"center\">349.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.98<\/td><td class=\"has-text-align-center\" data-align=\"center\">M5PFHxA<\/td><\/tr><tr><td>PFHxS<\/td><td class=\"has-text-align-center\" data-align=\"center\">398.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">398.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">M3PFHxS<\/td><\/tr><tr><td>PFHpS<\/td><td class=\"has-text-align-center\" data-align=\"center\">448.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">448.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">M9PFNA<\/td><\/tr><tr><td>PFOS<\/td><td class=\"has-text-align-center\" data-align=\"center\">498.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.89<\/td><td class=\"has-text-align-center\" data-align=\"center\">498.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">M8PFOS<\/td><\/tr><tr><td>PFNS<\/td><td class=\"has-text-align-center\" data-align=\"center\">548.65<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.89<\/td><td class=\"has-text-align-center\" data-align=\"center\">548.65<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">M7-PFUnDA<\/td><\/tr><tr><td>PFDS<\/td><td class=\"has-text-align-center\" data-align=\"center\">598.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">598.79<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.89<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2-PFDoA<\/td><\/tr><tr><td>PFUnDS<\/td><td class=\"has-text-align-center\" data-align=\"center\">648.65<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.88<\/td><td class=\"has-text-align-center\" data-align=\"center\">648.65<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2-PFDoA<\/td><\/tr><tr><td>PFTrDS<\/td><td class=\"has-text-align-center\" data-align=\"center\">748.59<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.88<\/td><td class=\"has-text-align-center\" data-align=\"center\">748.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.88<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2-PFTeDA<\/td><\/tr><tr><td>PFDoS<\/td><td class=\"has-text-align-center\" data-align=\"center\">698.71<\/td><td class=\"has-text-align-center\" data-align=\"center\">79.89<\/td><td class=\"has-text-align-center\" data-align=\"center\">698.71<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.88<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2-PFTeDA<\/td><\/tr><tr><td>FOSA<\/td><td class=\"has-text-align-center\" data-align=\"center\">497.75<\/td><td class=\"has-text-align-center\" data-align=\"center\">77.87<\/td><td class=\"has-text-align-center\" data-align=\"center\">497.75<\/td><td class=\"has-text-align-center\" data-align=\"center\">477.76<\/td><td class=\"has-text-align-center\" data-align=\"center\">M7-PFUnDA<\/td><\/tr><tr><td>ADONA<\/td><td class=\"has-text-align-center\" data-align=\"center\">376.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">84.97<\/td><td class=\"has-text-align-center\" data-align=\"center\">376.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">250.93<\/td><td class=\"has-text-align-center\" data-align=\"center\">M4PFHpA<\/td><\/tr><tr><td>HFPO-Da<\/td><td class=\"has-text-align-center\" data-align=\"center\">284.87<\/td><td class=\"has-text-align-center\" data-align=\"center\">168.89<\/td><td class=\"has-text-align-center\" data-align=\"center\">284.87<\/td><td class=\"has-text-align-center\" data-align=\"center\">184.83<\/td><td class=\"has-text-align-center\" data-align=\"center\">M5PFHxA<\/td><\/tr><tr><td>9Cl-PF3ONS<\/td><td class=\"has-text-align-center\" data-align=\"center\">530.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">350.85<\/td><td class=\"has-text-align-center\" data-align=\"center\">532.84<\/td><td class=\"has-text-align-center\" data-align=\"center\">352.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">M7-PFUnDA<\/td><\/tr><tr><td>11Cl-PF3OUdS<\/td><td class=\"has-text-align-center\" data-align=\"center\">630.71<\/td><td class=\"has-text-align-center\" data-align=\"center\">450.81<\/td><td class=\"has-text-align-center\" data-align=\"center\">632.71<\/td><td class=\"has-text-align-center\" data-align=\"center\">452.81<\/td><td class=\"has-text-align-center\" data-align=\"center\">M2-PFDoA<\/td><\/tr><tr><td>Capstone A<\/td><td class=\"has-text-align-center\" data-align=\"center\">526.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">180.96<\/td><td class=\"has-text-align-center\" data-align=\"center\">526.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">506.91<\/td><td class=\"has-text-align-center\" data-align=\"center\">M9PFNA<\/td><\/tr><tr><td>Capstone B<\/td><td class=\"has-text-align-center\" data-align=\"center\">568.81<\/td><td class=\"has-text-align-center\" data-align=\"center\">548.85<\/td><td class=\"has-text-align-center\" data-align=\"center\">568.81<\/td><td class=\"has-text-align-center\" data-align=\"center\">548.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">M9PFNA<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Results &amp; Discussion<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Chromatographic Performance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bile acids are often a concern when analyzing tissue samples for PFAS. Taurodeoxycholic acid (TDCA) is an endogenous bile acid that is formed in the liver and can be detected at high concentrations in biological samples. This compound, along with tauroursodeoxycholic acid (TUDCA) and taurochenodeoxycholic acid (TCDCA), all share the same mass transition (499 80) as PFOS and can also potentially interfere with FOSA. As a result, bile acids either need to be removed from the sample or be chromatographically resolved from the impacted compounds. It can be challenging to selectively remove bile acids from the sample without also removing analytes of interest; therefore, the chromatographic approach was taken here for the analysis of PFAS in milk samples.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Methanol and acetonitrile were both tested as organic mobile phases. Using a scouting gradient, methanol was tested first, and the results indicated that the use of this organic mobile phase would require significantly more method development to be able to potentially resolve the interferences. When using acetonitrile, all three bile acids were easily resolved from PFOS using the scouting conditions, but sensitivity for some of the PFAS was reduced compared to when using methanol. Therefore, a 50:50 mixture of the two organic modifiers was used, and it provided good sensitivity and resolution of the bile acids from PFOS. The final LC-MS\/MS method for the analysis of PFAS in milk used a 50:50 mixture of methanol and acetonitrile and can be seen in Figure 1.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:\u00a0<\/strong>Top: Chromatogram of 28 PFAS and Internal Standards (The PFAS that can potentially be affected by bile acid coelution are PFOS and FOSA.) Bottom: Chromatogram of Three Bile Acids Analyzed Using the Same Chromatographic Conditions<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0630.png\" alt=\"PFAS in Milk Fortified at 0.01 \u03bcg\/kg on Force C18 by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FF0630<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanoic acid (PFBA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-22-4\/Perfluorobutanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanoic acid (PFBA)<\/a><\/td><td class=\"oth\">212.94<\/td><td class=\"oth\">168.89<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoropentanoic acid (PFPeA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2706-90-3\/Perfluoropentanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoropentanoic acid (PFPeA)<\/a><\/td><td class=\"oth\">262.93<\/td><td class=\"oth\">218.89<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutane sulfonic acid (PFBS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-73-5\/Perfluorobutane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutane sulfonic acid (PFBS)<\/a><\/td><td class=\"oth\">298.96<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanoic acid (PFHxA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-24-4\/Perfluorohexanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanoic acid (PFHxA)<\/a><\/td><td class=\"oth\">313.09<\/td><td class=\"oth\">119.03<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexafluoropropylene oxide dimer acid (HFPO-DA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13252-13-6\/Hexafluoropropylene oxide dimer acid\" target=\"_blank\" rel=\"noopener\">Hexafluoropropylene oxide dimer acid (HFPO-DA)<\/a><\/td><td class=\"oth\">284.86<\/td><td class=\"oth\">168.88<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoropentane sulfonic acid (PFPeS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2706-91-4\/Perfluoropentane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluoropentane sulfonic acid (PFPeS)<\/a><\/td><td class=\"oth\">349.10<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroheptanoic acid (PFHpA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-85-9\/Perfluoroheptanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroheptanoic acid (PFHpA)<\/a><\/td><td class=\"oth\">363.15<\/td><td class=\"oth\">169.06<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for Ammonium 4,8-dioxa-3<i>H<\/i>-perfluorononanoate (ADONA)&#8221; title=&#8221;View compound information for Ammonium 4,8-dioxa-3<i>H<\/i>-perfluorononanoate (ADONA)&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/919005-14-4\/Ammonium 4,8-dioxa-3<i>H-perfluorononanoate&#8221;&gt;Ammonium 4,8-dioxa-3<i>H<\/i>-perfluorononanoate (ADONA)<\/a><\/td><td class=\"oth\">376.90<\/td><td class=\"oth\">84.97<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexane sulfonic acid (PFHxS)\t\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/355-46-4\/Perfluorohexane sulfonic acid (PFHxS)\t\" target=\"_blank\" rel=\"noopener\">Perfluorohexane sulfonic acid (PFHxS)\t<\/a><\/td><td class=\"oth\">398.80<\/td><td class=\"oth\">79.82<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">413.09<\/td><td class=\"oth\">168.90<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroheptane sulfonic acid (PFHpS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-92-8\/Perfluoroheptane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroheptane sulfonic acid (PFHpS)<\/a><\/td><td class=\"oth\">448.78<\/td><td class=\"oth\">79.82<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for 1-Propanaminium, <i>N<\/i>-(carboxymethyl)-<i>N,N<\/i>-dimethyl-3-[[(3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctyl)sulfonyl]amino]-, hydroxide (Capstone B)&#8221; title=&#8221;View compound information for 1-Propanaminium, <i>N<\/i>-(carboxymethyl)-<i>N,N<\/i>-dimethyl-3-[[(3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctyl)sulfonyl]amino]-, hydroxide (Capstone B)&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/34455-29-3\/1-Propanaminium, <i>N-(carboxymethyl)-<i>N,N-dimethyl-3-[[(3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctyl)sulfonyl]amino]-, hydroxide&#8221;&gt;1-Propanaminium, <i>N<\/i>-(carboxymethyl)-<i>N,N<\/i>-dimethyl-3-[[(3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctyl)sulfonyl]amino]-, hydroxide (Capstone B)<\/a><\/td><td class=\"oth\">568.81<\/td><td class=\"oth\">548.85<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononanoic acid (PFNA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-95-1\/Perfluorononanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononanoic acid (PFNA)<\/a><\/td><td class=\"oth\">463.09<\/td><td class=\"oth\">219.01<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for 1-Propanaminium, <i>N,N<\/i>-dimethyl-<i>N<\/i>-oxide-3-[[(3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctyl)sulfonyl]amino]-, hydroxide (Capstone A)&#8221; title=&#8221;View compound information for 1-Propanaminium, <i>N,N<\/i>-dimethyl-<i>N<\/i>-oxide-3-[[(3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctyl)sulfonyl]amino]-, hydroxide (Capstone A)&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/80475-32-7\/1-Propanaminium, <i>N,N-dimethyl-<i>N-oxide-3-[[(3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctyl)sulfonyl]amino]-, hydroxide&#8221;&gt;1-Propanaminium, <i>N,N<\/i>-dimethyl-<i>N<\/i>-oxide-3-[[(3,3,4,4,5,5,6,6,7,7,8,8,8-tridecafluorooctyl)sulfonyl]amino]-, hydroxide (Capstone A)<\/a><\/td><td class=\"oth\">526.90<\/td><td class=\"oth\">180.96<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctane sulfonic acid (PFOS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1763-23-1\/Perfluorooctane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctane sulfonic acid (PFOS)<\/a><\/td><td class=\"oth\">498.78<\/td><td class=\"oth\">79.89<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecanoic acid (PFDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-76-2\/Perfluorodecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecanoic acid (PFDA)<\/a><\/td><td class=\"oth\">513.16<\/td><td class=\"oth\">219.06<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/756426-58-1\/9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid\" target=\"_blank\" rel=\"noopener\">9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS)<\/a><\/td><td class=\"oth\">530.77<\/td><td class=\"oth\">350.85<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononane sulfonic acid (PFNS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68259-12-1\/Perfluorononane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononane sulfonic acid (PFNS)<\/a><\/td><td class=\"oth\">548.65<\/td><td class=\"oth\">79.89<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroundecanoic acid (PFUnA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2058-94-8\/Perfluoroundecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroundecanoic acid (PFUnA)<\/a><\/td><td class=\"oth\">562.78<\/td><td class=\"oth\">268.82<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctane sulfonic acid (FOSA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1763-23-1\/Perfluorooctane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctane sulfonic acid (FOSA)<\/a><\/td><td class=\"oth\">497.75<\/td><td class=\"oth\">77.87<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecane sulfonic acid (PFDS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-77-3\/Perfluorodecane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecane sulfonic acid (PFDS)<\/a><\/td><td class=\"oth\">598.78<\/td><td class=\"oth\">98.82<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorododecanoic acid (PFDoA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-55-1\/Perfluorododecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorododecanoic acid (PFDoA)<\/a><\/td><td class=\"oth\">612.52<\/td><td class=\"oth\">318.90<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-chloroeicosafluoro-3-oxaundecane-1sulfonic acid (11Cl-PF3OUdS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/763051-92-9\/11-chloroeicosafluoro-3-oxaundecane-1sulfonic acid\" target=\"_blank\" rel=\"noopener\">11-chloroeicosafluoro-3-oxaundecane-1sulfonic acid (11Cl-PF3OUdS)<\/a><\/td><td class=\"oth\">630.71<\/td><td class=\"oth\">450.81<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroundecane sulfonic acid (PFUnDS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/749786-16-1\/Perfluoroundecane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroundecane sulfonic acid (PFUnDS)<\/a><\/td><td class=\"oth\">648.65<\/td><td class=\"oth\">79.88<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotridecanoic acid (PFTrDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72629-94-8\/Perfluorotridecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotridecanoic acid (PFTrDA)<\/a><\/td><td class=\"oth\">662.78<\/td><td class=\"oth\">168.87<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorododecane sulfonic acid (PFDoS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79780-39-5\/Perfluorododecane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorododecane sulfonic acid (PFDoS)<\/a><\/td><td class=\"oth\">698.71<\/td><td class=\"oth\">79.89<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotetradecanoic acid (PFTeDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/376-06-7\/Perfluorotetradecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotetradecanoic acid (PFTeDA)<\/a><\/td><td class=\"oth\">712.78<\/td><td class=\"oth\">168.87<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotridecane sulfonic acid (PFTrDS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/791563-89-8\/Perfluorotridecane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotridecane sulfonic acid (PFTrDS)<\/a><\/td><td class=\"oth\">748.59<\/td><td class=\"oth\">79.88<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Force C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9634352\" rel=\"noopener\">cat.# 9634352<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>3 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>100 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Force EXP C18 guard cartridge 5 mm, 2.1 mm ID (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/963450252\" rel=\"noopener\">cat.# 963450252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>50 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>PFAS 28 calibration standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30734\" rel=\"noopener\">cat.# 30734<\/a>)<\/td><\/tr><tr><td><\/td><td>Other standards obtained externally.<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Methanol:water (60:40)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>Analytes spiked at 0.01 \u03bcg\/kg in milk <\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 5 mM ammonium acetate <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol:acetonitrile (50:50) <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>3.00<\/td><td>0.6<\/td><td>60<\/td><td>40<\/td><\/tr><tr><td>9.00<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>9.50<\/td><td>0.6<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>10.50<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>11.00<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>11.01<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>13.00<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>360 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ Absolute<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY Premier<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Ten grams of milk were weighed into a 50 mL centrifuge tube (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25846\" rel=\"noopener\">cat.# 25846<\/a>) and fortified at 0.01 \u03bcg\/kg. Isotopically labeled internal standards (50 \u03bcL) were spiked into the sample and briefly vortexed. Acetonitrile (10 mL); formic acid (150 \u03bcL); and a Q-sep QuEChERS extraction salt packet (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25847\" rel=\"noopener\">cat.# 25847<\/a>) were added to the sample and vortexed for ~30 seconds. The samples were transferred to a shaker table and shaken for 10 minutes. The samples were then centrifuged for 5 minutes at 4200 rpm. The supernatant was aliquoted into a Q-sep QuEChERS dSPE 15 mL centrifuge tube containing 900 mg MgSO4; 300 mg PSA; and 150 mg GCB (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/26126\" rel=\"noopener\">cat.# 26126<\/a>) and then vortexed for ~30 seconds followed by centrifuging for 5 minutes at 4200 rpm. The supernatant was aliquoted (6 mL) into a clean 15 mL centrifuge tube and dried down at 35 \u00b0C for 90 minutes using a Biotage TurboVap. The samples were reconstituted in methanol:water 60:40 (400 \u03bcL); vortexed for ~30 seconds; and centrifuged for 5 minutes at 4200 rpm. The supernatant was aliquoted into a polypropylene vial (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23243\" rel=\"noopener\">cat.# 23243<\/a>) and capped with a polyethylene screw cap (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23244\" rel=\"noopener\">cat.# 23244<\/a>) and 5 \u03bcL was injected for analysis.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>A PFAS delay column (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/27854\" rel=\"noopener\">cat.# 27854<\/a>) was installed before the injector.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30734<\/li><li>963450252<\/li><li>9634352<\/li><li>27854<\/li><li>25846<\/li><li>25847<\/li><li>26126<\/li><li>23243<\/li><li>23244<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>pfas-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0630.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Linearity, Accuracy, &amp; Precision<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For this LC-MS\/MS method for the analysis of PFAS in milk, calibration was performed across a range of 0.03\/0.1\u201350 ng\/mL at seven or eight different concentrations. To assess linearity, 1\/x weighting was used. Good linearity was demonstrated by R<sup>2<\/sup>&nbsp;values \u2265 0.991 for all compounds (Table III).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Three different milk samples were obtained and fortified at 1X target LOQ and 5X target LOQ levels (0.01 \u00b5g\/kg and 0.05 \u00b5g\/kg, respectively). Blank samples were prepared in duplicate and analyzed in triplicate. Milk samples were prepared in triplicate and analyzed in triplicate. Analytes detected in the blank samples are identified by an asterisk in Tables II and III, and incurred levels were subtracted from the fortified samples. Excellent recoveries were obtained at the LOQ spiking level for all four of the PFAS assessed by the EFSA. These recoveries were 101\u2013112% at 0.01 \u00b5g\/kg, and excellent precision was demonstrated by %RSDs of 3.81\u201316.6% (Table II).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong>&nbsp;Percent Recoveries and %RSD at 0.01 \u00b5g\/kg for the Four PFAS Assessed by EFSA<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-background has-fixed-layout\" style=\"background-color:#ced4d9;border-width:1px\"><thead><tr><th><\/th><th class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\"><strong>Average Percent Recovery (%RSD) n=9<\/strong><\/th><\/tr><tr><th><\/th><th class=\"has-text-align-center\" data-align=\"center\">Sample 1<\/th><th class=\"has-text-align-center\" data-align=\"center\">Sample 2<\/th><th class=\"has-text-align-center\" data-align=\"center\">Sample 3<\/th><\/tr><\/thead><tbody><tr><td>PFOA*<\/td><td class=\"has-text-align-center\" data-align=\"center\">108 (5.09)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (6.21)<\/td><td class=\"has-text-align-center\" data-align=\"center\">105 (7.74)<\/td><\/tr><tr><td>PFNA<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (7.97)<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (8.19)<\/td><td class=\"has-text-align-center\" data-align=\"center\">101 (16.6)<\/td><\/tr><tr><td>PFHxS<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (5.93)<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (7.25)<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (12.8)<\/td><\/tr><tr><td>PFOS*<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (7.25)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (3.81)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (6.72)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Incurred levels were present in the blank samples for these analytes and were subtracted from the fortified samples.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Most of the 28 PFAS monitored in these experiments had acceptable recoveries within the 80\u2013120% range. Some long-chain PFAS showed low percent recoveries, namely PFTrDA, PFTeDA, PFUnDS, PFTrDS, PFDoS, FOSA, and Capstone B, which contain carbon chains of eight to thirteen carbons. Low recoveries were not observed in Sample 2, the fat-free milk, indicating that the presence of milk fat in the other samples could potentially be hindering the recoveries for these compounds. A summary of the linear dynamic range, R<sup>2<\/sup>&nbsp;values, percent recoveries, and percent RSD values can be seen in Table III for all 28 PFAS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong>&nbsp;Linearity, Accuracy, and Precision in Milk<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-background\" style=\"background-color:#ced4d9;border-width:1px\"><thead><tr><th rowspan=\"3\">Compound<\/th><th class=\"has-text-align-center\" data-align=\"center\" colspan=\"3\" rowspan=\"2\">Linear Range (ng\/mL)<\/th><th class=\"has-text-align-center\" data-align=\"center\" colspan=\"6\"><strong>Percent Recovery (Percent RSD) n=9<\/strong><\/th><\/tr><tr><th colspan=\"2\"><strong>Sample 1<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><strong>Sample 2<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><strong>Sample 3<\/strong><\/th><\/tr><tr><th><strong>Low<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>High<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>R<sup>2<\/sup><\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>0.01 \u00b5g\/kg<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>0.05 \u00b5g\/kg<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>0.01 \u00b5g\/kg<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>0.05 \u00b5g\/kg<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>0.01 \u00b5g\/kg<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>0.05 \u00b5g\/kg<\/strong><\/th><\/tr><\/thead><tbody><tr><td>PFBA*<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.996<\/td><td class=\"has-text-align-center\" data-align=\"center\">90.1 (4.81)<\/td><td class=\"has-text-align-center\" data-align=\"center\">105 (7.06)<\/td><td class=\"has-text-align-center\" data-align=\"center\">103 (8.61)<\/td><td class=\"has-text-align-center\" data-align=\"center\">116 (2.91)<\/td><td class=\"has-text-align-center\" data-align=\"center\">115 (11.5)<\/td><td class=\"has-text-align-center\" data-align=\"center\">116 (4.95)<\/td><\/tr><tr><td>PFPeA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.996<\/td><td class=\"has-text-align-center\" data-align=\"center\">105 (7.89)<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 (5.45)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (6.72)<\/td><td class=\"has-text-align-center\" data-align=\"center\">111 (2.55)<\/td><td class=\"has-text-align-center\" data-align=\"center\">107 (10.8)<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (2.80)<\/td><\/tr><tr><td>PFHxA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.996<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (10.6)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (5.13)<\/td><td class=\"has-text-align-center\" data-align=\"center\">104 (8.11)<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (5.49)<\/td><td class=\"has-text-align-center\" data-align=\"center\">118 (11.3)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (6.11)<\/td><\/tr><tr><td>PFHpA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.997<\/td><td class=\"has-text-align-center\" data-align=\"center\">117 (5.09)<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (7.31)<\/td><td class=\"has-text-align-center\" data-align=\"center\">108 (7.14)<\/td><td class=\"has-text-align-center\" data-align=\"center\">115 (2.69)<\/td><td class=\"has-text-align-center\" data-align=\"center\">111 (16.2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">118 (4.21)<\/td><\/tr><tr><td>PFOA*<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.995<\/td><td class=\"has-text-align-center\" data-align=\"center\">108 (5.09)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (4.62)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (6.21)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (2.56)<\/td><td class=\"has-text-align-center\" data-align=\"center\">105 (7.74)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (3.28)<\/td><\/tr><tr><td>PFNA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.996<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (7.97)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (2.63)<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (8.19)<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 (3.81)<\/td><td class=\"has-text-align-center\" data-align=\"center\">101 (16.6)<\/td><td class=\"has-text-align-center\" data-align=\"center\">101 (10.4)<\/td><\/tr><tr><td>PFDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.997<\/td><td class=\"has-text-align-center\" data-align=\"center\">111 (9.02)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (5.55)<\/td><td class=\"has-text-align-center\" data-align=\"center\">107 (6.08)<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (4.13)<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (7.38)<\/td><td class=\"has-text-align-center\" data-align=\"center\">115 (3.26)<\/td><\/tr><tr><td>PFUnDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.992<\/td><td class=\"has-text-align-center\" data-align=\"center\">104 (7.52)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (11.6)<\/td><td class=\"has-text-align-center\" data-align=\"center\">103 (10.9)<\/td><td class=\"has-text-align-center\" data-align=\"center\">107 (7.57)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (8.90)<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 (4.54)<\/td><\/tr><tr><td>PFDoA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.997<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 (7.57)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (4.34)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (6.72)<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (2.76)<\/td><td class=\"has-text-align-center\" data-align=\"center\">108 (9.77)<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (2.45)<\/td><\/tr><tr><td>PFTrDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.999<\/td><td class=\"has-text-align-center\" data-align=\"center\">75.9 (12.5)<\/td><td class=\"has-text-align-center\" data-align=\"center\">65.8 (7.68)<\/td><td class=\"has-text-align-center\" data-align=\"center\">86.7 (8.95)<\/td><td class=\"has-text-align-center\" data-align=\"center\">73.3 (8.64)<\/td><td class=\"has-text-align-center\" data-align=\"center\">71.8 (11.0)<\/td><td class=\"has-text-align-center\" data-align=\"center\">68.8 (12.2)<\/td><\/tr><tr><td>PFTeDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.997<\/td><td class=\"has-text-align-center\" data-align=\"center\">83.2 (14.5)<\/td><td class=\"has-text-align-center\" data-align=\"center\">83.8 (12.4)<\/td><td class=\"has-text-align-center\" data-align=\"center\">103 (6.91)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (8.95)<\/td><td class=\"has-text-align-center\" data-align=\"center\">74.1 (17.2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">78.4 (11.3)<\/td><\/tr><tr><td>PFBS*<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.995<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (11.9)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (11.4)<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 (11.2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (5.21)<\/td><td class=\"has-text-align-center\" data-align=\"center\">103 (7.18)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (5.32)<\/td><\/tr><tr><td>PFPeS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.996<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (6.32)<\/td><td class=\"has-text-align-center\" data-align=\"center\">119 (5.78)<\/td><td class=\"has-text-align-center\" data-align=\"center\">105 (6.19)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (4.87)<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (8.03)<\/td><td class=\"has-text-align-center\" data-align=\"center\">115 (5.08)<\/td><\/tr><tr><td>PFHxS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.996<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (5.93)<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (5.29)<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (7.25)<\/td><td class=\"has-text-align-center\" data-align=\"center\">111 (3.59)<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (12.8)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (3.92)<\/td><\/tr><tr><td>PFHpS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.995<\/td><td class=\"has-text-align-center\" data-align=\"center\">117 (5.14)<\/td><td class=\"has-text-align-center\" data-align=\"center\">121 (9.15)<\/td><td class=\"has-text-align-center\" data-align=\"center\">112 (5.57)<\/td><td class=\"has-text-align-center\" data-align=\"center\">116 (3.81)<\/td><td class=\"has-text-align-center\" data-align=\"center\">121 (5.04)<\/td><td class=\"has-text-align-center\" data-align=\"center\">119 (5.32)<\/td><\/tr><tr><td>PFOS*<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.995<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (7.25)<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 (7.21)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (3.81)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113(4.03)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (6.72)<\/td><td class=\"has-text-align-center\" data-align=\"center\">107 (4.62)<\/td><\/tr><tr><td>PFNS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.999<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (17.1)<\/td><td class=\"has-text-align-center\" data-align=\"center\">88.5 (18.1)<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 (11.5)<\/td><td class=\"has-text-align-center\" data-align=\"center\">90.1 (15.4)<\/td><td class=\"has-text-align-center\" data-align=\"center\">103 (15.5)<\/td><td class=\"has-text-align-center\" data-align=\"center\">84.3 (19.9)<\/td><\/tr><tr><td>PFDS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.997<\/td><td class=\"has-text-align-center\" data-align=\"center\">92.6 (11.7)<\/td><td class=\"has-text-align-center\" data-align=\"center\">95.8 (6.01)<\/td><td class=\"has-text-align-center\" data-align=\"center\">101 (7.31)<\/td><td class=\"has-text-align-center\" data-align=\"center\">100 (9.33)<\/td><td class=\"has-text-align-center\" data-align=\"center\">99.2 (12.3)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (11.8)<\/td><\/tr><tr><td>PFUnDS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.997<\/td><td class=\"has-text-align-center\" data-align=\"center\">74.2 (9.48)<\/td><td class=\"has-text-align-center\" data-align=\"center\">95.5 (9.11)<\/td><td class=\"has-text-align-center\" data-align=\"center\">100 (9.94)<\/td><td class=\"has-text-align-center\" data-align=\"center\">113 (9.25)<\/td><td class=\"has-text-align-center\" data-align=\"center\">81.4 (20.7)<\/td><td class=\"has-text-align-center\" data-align=\"center\">104 (12.7)<\/td><\/tr><tr><td>PFTrDS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.994<\/td><td class=\"has-text-align-center\" data-align=\"center\">67.9 (15.6)<\/td><td class=\"has-text-align-center\" data-align=\"center\">46.2 (9.53)<\/td><td class=\"has-text-align-center\" data-align=\"center\">88.1 (14.1)<\/td><td class=\"has-text-align-center\" data-align=\"center\">95.5 (10.6)<\/td><td class=\"has-text-align-center\" data-align=\"center\">43.2 (15.1)<\/td><td class=\"has-text-align-center\" data-align=\"center\">55.5 (6.04)<\/td><\/tr><tr><td>PFDoS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.997<\/td><td class=\"has-text-align-center\" data-align=\"center\">55.6 (9.8)<\/td><td class=\"has-text-align-center\" data-align=\"center\">59.6 (8.22)<\/td><td class=\"has-text-align-center\" data-align=\"center\">96.3 (10.0)<\/td><td class=\"has-text-align-center\" data-align=\"center\">103 (9.33)<\/td><td class=\"has-text-align-center\" data-align=\"center\">62.1 (11.5)<\/td><td class=\"has-text-align-center\" data-align=\"center\">73.9 (7.29)<\/td><\/tr><tr><td>FOSA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.992<\/td><td class=\"has-text-align-center\" data-align=\"center\">60.8 (12.6)<\/td><td class=\"has-text-align-center\" data-align=\"center\">59.4 (10.2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">92.6 (8.16)<\/td><td class=\"has-text-align-center\" data-align=\"center\">95.5 (9.41)<\/td><td class=\"has-text-align-center\" data-align=\"center\">87.1 (15.3)<\/td><td class=\"has-text-align-center\" data-align=\"center\">84.0 (12.5)<\/td><\/tr><tr><td>ADONA<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.996<\/td><td class=\"has-text-align-center\" data-align=\"center\">111 (7.17)<\/td><td class=\"has-text-align-center\" data-align=\"center\">109 (7.91)<\/td><td class=\"has-text-align-center\" data-align=\"center\">93.8 (11.3)<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.9 (4.52)<\/td><td class=\"has-text-align-center\" data-align=\"center\">93.8 (9.54)<\/td><td class=\"has-text-align-center\" data-align=\"center\">104 (6.00)<\/td><\/tr><tr><td>HFPO-Da<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.996<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (13.7)<\/td><td class=\"has-text-align-center\" data-align=\"center\">110 (7.69)<\/td><td class=\"has-text-align-center\" data-align=\"center\">111 (15.4)<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (12.7)<\/td><td class=\"has-text-align-center\" data-align=\"center\">125 (9.00)<\/td><td class=\"has-text-align-center\" data-align=\"center\">124 (4.31)<\/td><\/tr><tr><td>9Cl-PF3ONS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.992<\/td><td class=\"has-text-align-center\" data-align=\"center\">94.5 (3.37)<\/td><td class=\"has-text-align-center\" data-align=\"center\">99.3 (8.09)<\/td><td class=\"has-text-align-center\" data-align=\"center\">96.6 (10.3)<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.9 (7.64)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (12.8)<\/td><td class=\"has-text-align-center\" data-align=\"center\">106 (6.08)<\/td><\/tr><tr><td>11Cl-PF3OUdS<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.997<\/td><td class=\"has-text-align-center\" data-align=\"center\">93.5 (6.74)<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.8 (6.78)<\/td><td class=\"has-text-align-center\" data-align=\"center\">103 (12.2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (10.0)<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.7 (11.2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (13.1)<\/td><\/tr><tr><td>Capstone A<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.991<\/td><td class=\"has-text-align-center\" data-align=\"center\">120 (12.1)<\/td><td class=\"has-text-align-center\" data-align=\"center\">126 (9.27)<\/td><td class=\"has-text-align-center\" data-align=\"center\">102 (16.5)<\/td><td class=\"has-text-align-center\" data-align=\"center\">108 (7.34)<\/td><td class=\"has-text-align-center\" data-align=\"center\">119 (6.44)<\/td><td class=\"has-text-align-center\" data-align=\"center\">114 (5.06)<\/td><\/tr><tr><td>Capstone B<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">50<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.992<\/td><td class=\"has-text-align-center\" data-align=\"center\">92.1 (11.6)<\/td><td class=\"has-text-align-center\" data-align=\"center\">68.3 (10.9)<\/td><td class=\"has-text-align-center\" data-align=\"center\">85.1 (15.2)<\/td><td class=\"has-text-align-center\" data-align=\"center\">71.7 (8.24)<\/td><td class=\"has-text-align-center\" data-align=\"center\">84.6 (15.3)<\/td><td class=\"has-text-align-center\" data-align=\"center\">71.4 (10.6)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Incurred levels were present in the blank samples for these analytes and were subtracted from the fortified samples.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 2 outlines the results for the analysis of all 28 PFAS in milk samples using this LC-MS\/MS method. At 0.01 \u00b5g\/kg, 82% of analytes meet the 80\u2013120% recovery range for Sample 1; 100% did for Sample 2; and 79% did for Sample 3. All but one analyte, PFUnDS, returned a %RSD value of \u226420%.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0Percentage of Analytes in Each Sample Meeting the Acceptable Accuracy and Precision Criteria at 0.01 \u00b5g\/kg for the Analysis of PFAS in Milk<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45261_1cdbf8-3e .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45261_1cdbf8-3e\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"616\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-fsan4338-02a-1024x616.jpg\" alt=\"\" class=\"kb-img wp-image-24118\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-fsan4338-02a-1024x616.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-fsan4338-02a-300x180.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-fsan4338-02a-768x462.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-fsan4338-02a-1536x923.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-fsan4338-02a.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This workflow provides straightforward and reliable methodology for the analysis of 28 PFAS in milk by LC-MS\/MS. The method effectively separates target analytes from bile acid interferences that share the same mass transition. With a fast, simple sample preparation using QuEChERS extraction and dSPE cleanup, this workflow is ideal for high-throughput PFAS testing labs. The results showed exceptional results for the four PFAS assessed by the EFSA, and acceptable results for the majority of the other analytes. The recoveries of a few of the long-chain PFAS returned low values, which may be related to the presence of fat in milk samples. Although the recoveries for these compounds were low, the precision of the method was still within the acceptable range. This method can easily be implemented in labs to confidently monitor PFAS contamination in dairy milk.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">References<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Agency for Toxic Substances and Disease Registry. PFAS information for clinicians. Fact sheet. January 2024. https:\/\/www.atsdr.cdc.gov\/pfas\/docs\/PFAS-info-for-clinicians-508.pdf&nbsp;<\/li>\n\n\n\n<li>Food and Agricultural Organization of the United Nations. Gateway to diary production and products. &nbsp;2024. https:\/\/www.fao.org\/dairy-production-products\/en&nbsp;<\/li>\n\n\n\n<li>D. Schrenk, et al., Risk to human health related to the presence of perfluoroalkyl substances in food, EFSA J 18, (9) 2020. https:\/\/efsa.onlinelibrary.wiley.com\/doi\/10.2903\/j.efsa.2020.6223&nbsp;<\/li>\n\n\n\n<li>Maine Department of Agriculture, Conservation, &amp; Forestry. PFAS response. 202. https:\/\/www.maine.gov\/dacf\/ag\/pfas\/pfas-response.shtml<\/li>\n\n\n\n<li>European Union Reference Laboratory for Halogenated Persistent Organic Pollutants in Feed and Food. Guidance document on analytical parameters for the determination of per- and polyfluoroalkyl substances (PFAS) in food and feed. Version 1.2. May 2022. https:\/\/eurl-pops.eu\/news\/guidance-document-pfas\/guidance-document-pfas<\/li>\n<\/ol>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634352\">                                \u8d27\u53f7\uff1a 9634352                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force C18, 3 \u00b5m, 50 x 2.1 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634352\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/963450252\">                                \u8d27\u53f7\uff1a 963450252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force C18 Guard Cartridge, 5 x 2.1 mm EXP, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/963450252\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u8d27\u53f7\uff1a 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS Delay Column, 5 \u00b5m, 50 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30734\">                                \u8d27\u53f7\uff1a 30734                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS 28 Calibration Standard, 1 \u00b5g\/mL, Methanol (1 mM KOH), 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30734\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25846\">                                \u8d27\u53f7\uff1a 25846                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Empty Centrifuge Tubes, 50 mL, Polypropylene w\/Cap, 50-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25846\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25847\">                                \u8d27\u53f7\uff1a 25847                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS Extraction Salt Packets Only (Original), 4 g MgSO4, 1 g NaCl, 50 Packets<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25847\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26126\">                                \u8d27\u53f7\uff1a 26126                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS dSPE 15 mL Centrifuge Tube, Contains 900 mg MgSO4, 300 mg PSA, 150 mg GCB, 50 Tubes<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26126\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23243\">                                \u8d27\u53f7\uff1a 23243                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Limited-Volume Screw-Thread Polypropylene Vials, 9 mm, 700 \u00b5L, 12 x 32 mm, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23243\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23244\">                                \u8d27\u53f7\uff1a 23244                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">2.0 mL, 9 mm Solid-Top Polyethylene Caps, Screw-Thread, 10 mil thick membrane, Clear, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23244\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column99903_13002f-36 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column99903_13002f-36 > .kt-inside-inner-col,.kadence-column99903_13002f-36 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column99903_13002f-36 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_13002f-36 > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_13002f-36 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_13002f-36 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_13002f-36{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_13002f-36 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_13002f-36 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_13002f-36 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id99903_d4b38f-90 > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id99903_d4b38f-90 > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id99903_d4b38f-90 > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id99903_d4b38f-90{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id99903_d4b38f-90 > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id99903_d4b38f-90 > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id99903_d4b38f-90 > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id99903_d4b38f-90 > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id99903_d4b38f-90 alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column99903_e9827f-3e > .kt-inside-inner-col,.kadence-column99903_e9827f-3e > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column99903_e9827f-3e > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_e9827f-3e > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_e9827f-3e > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_e9827f-3e > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_e9827f-3e{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_e9827f-3e > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_e9827f-3e > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_e9827f-3e\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b, .wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b[data-kb-block=\"kb-adv-heading99903_c05470-6b\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b, .wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b[data-kb-block=\"kb-adv-heading99903_c05470-6b\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b[data-kb-block=\"kb-adv-heading99903_c05470-6b\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b[data-kb-block=\"kb-adv-heading99903_c05470-6b\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b, .wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b[data-kb-block=\"kb-adv-heading99903_c05470-6b\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b, .wp-block-kadence-advancedheading.kt-adv-heading99903_c05470-6b[data-kb-block=\"kb-adv-heading99903_c05470-6b\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading99903_c05470-6b wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading99903_c05470-6b\"><span class=\"kb-adv-text-inner\">\u60a8\u7684PFAS\u5206\u6790\u9700\u8981\u5e2e\u52a9\u5417\uff1f<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-f665c15039f1a4afbba75872873e13a0 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">\u4ece\u65b9\u6cd5\u9009\u62e9\u5230\u4ea7\u54c1\u63a8\u8350\uff0cRestek PFAS \u4e13\u5bb6\u52a9\u60a8\u5e94\u5bf9\u590d\u6742\u5206\u6790\u6d41\u7a0b\uff0c\u83b7\u5f97\u51c6\u786e\u3001\u53ef\u9760\u7684\u5206\u6790\u7ed3\u679c\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns99903_cbdd3e-ae{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns99903_cbdd3e-ae .kt-button{font-weight:normal;font-style:normal;}.kt-btns99903_cbdd3e-ae .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns99903_cbdd3e-ae .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns99903_cbdd3e-ae .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_cbdd3e-ae .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns99903_cbdd3e-ae .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns99903_cbdd3e-ae .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_cbdd3e-ae .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns99903_cbdd3e-ae\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn99903_1b0338-26.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn99903_1b0338-26.kb-button:hover .kb-svg-icon-wrap, .kb-btn99903_1b0338-26.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_1b0338-26.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn99903_1b0338-26 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn\" href=\"https:\/\/explore.restek.com\/PFAS\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>\u8054\u7cfbPFAS\u5206\u6790\u4e13\u5bb6<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This LC-MS\/MS method for the analysis of PFAS in milk prevents interferences from bile acids and produces excellent results for 28 PFAS, including the EFSA PFAS (PFOS, PFOA, PFHxS, and PFNA).<\/p>\n","protected":false},"author":47,"featured_media":6973,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2805],"tags":[2782],"industries-application":[2167,2169,2165],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2299,2302,2303],"ppma_author":[579],"class_list":["post-45261","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","tag-pfas","industries-application-food-beverage","industries-application-food-safety","industries-application-pfas-testing","resource-technique-liquid-chromatography","resource-technique-ms-ms","resource-technique-quechers"],"acf":[],"taxonomy_info":{"category":[{"value":2805,"label":"Application Notes"}],"post_tag":[{"value":2782,"label":"PFAS"}],"industries-application":[{"value":2167,"label":"Food &amp; Beverage"},{"value":2169,"label":"Food Safety"},{"value":2165,"label":"PFAS Testing"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2302,"label":"MS\/MS"},{"value":2303,"label":"QuEChERS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSAN4338-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Jamie L. York, PhD","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/jamie-l-york-phd\/"},"comment_info":0,"category_info":[{"term_id":2805,"name":"Application Notes","slug":"application-notes","term_group":0,"term_taxonomy_id":2805,"taxonomy":"category","description":"","parent":0,"count":78,"filter":"raw","cat_ID":2805,"category_count":78,"category_description":"","cat_name":"Application Notes","category_nicename":"application-notes","category_parent":0}],"tag_info":[{"term_id":2782,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2782,"taxonomy":"post_tag","description":"","parent":0,"count":114,"filter":"raw"}],"authors":[{"term_id":579,"user_id":47,"is_guest":0,"slug":"jamie-l-york-phd","display_name":"Jamie L. York, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg"},"author_category":"1","first_name":"Jamie","last_name":"York","user_url":"https:\/\/www.linkedin.com\/in\/jamielyork\/","job_title":"Principal Scientist, LC Solutions","description":"Jamie York is a principal scientist in the Applications Lab at Restek Corporation. She leads the development of innovative analytical methods tailored to the food, clinical, environmental, and cannabis markets. Jamie earned her PhD in chemistry from The University of Texas at Arlington, where she gained extensive expertise in a range of analytical techniques, including gas chromatography\u2013vacuum ultraviolet (GC\u2013VUV); gas chromatography\u2013mass spectrometry (GC\u2013MS); matrix-assisted laser desorption\/ionization (MALDI); and liquid chromatography\u2013 mass spectrometry (LC\u2013MS\/MS); with a research emphasis on food and environmental analysis. Today, her work focuses on complex method development and advanced sample preparation strategies to support the evolving needs of the scientific community."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45261","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=45261"}],"version-history":[{"count":9,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45261\/revisions"}],"predecessor-version":[{"id":99913,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45261\/revisions\/99913"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media\/6973"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=45261"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=45261"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=45261"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=45261"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=45261"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=45261"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=45261"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=45261"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=45261"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}