{"id":45267,"date":"2025-10-08T17:55:39","date_gmt":"2025-10-08T17:55:39","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/c1-c10-pfas-analysis-in-human-plasma-and-serum\/"},"modified":"2026-08-05T17:28:20","modified_gmt":"2026-08-05T17:28:20","slug":"c1-c10-pfas-analysis-in-human-plasma-and-serum","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/application-notes-it\/cfan4273\/c1-c10-pfas-analysis-in-human-plasma-and-serum","title":{"rendered":"C1-C10 PFAS Analysis in Human Plasma and Serum"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Abstract<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Human exposure to ultrashort-chain (C1 to C3) PFAS and their potential adverse health effects are poorly understood, partly due to a lack of analytical methods to properly monitor their occurrence. This study introduces an innovative methodology for the simultaneous analysis of C1 to C10 carboxylic and sulfonic acid PFAS, along with four alternative compounds, in human plasma and serum samples. The chromatographic analysis was conducted using a polar-embedded, reversed-phase LC column for accurate and robust quantification.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">While concerns about the adverse effects of long-chain per- and polyfluoroalkyl substances (PFAS) on human health have led to increased biomonitoring, less is known about the potential toxicity of ultrashort-chain PFAS. Ultrashort-chain PFAS are ubiquitous in environmental aquatic systems and can occur at very high concentrations, so determining exposure levels is important, particularly for vulnerable populations. Since both human plasma and serum are widely used for biomonitoring longer-chain PFAS, developing methods that include shorter chain PFAS is critical to gaining a more comprehensive understanding of the relationship between PFAS exposure and adverse health outcomes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ultrashort-chain PFAS are small, highly polar compounds with carbon chain lengths shorter than C4 (Figure 1). Their high polarity creates a challenge for analytical practices that are based on reversed-phase liquid chromatography, primarily due to insufficient chromatographic retention. To improve analytical performance, the following method was developed on an Ultra IBD column because its polar-embedded stationary phase provides stronger retention of polar compounds, even in the presence of the various salts, electrolytes, and buffers that are inherently found in human plasma and serum.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this study, a simple and reliable workflow was developed for the simultaneous analysis of C1 to C10 perfluoroalkyl carboxylic and sulfonic acids, along with four alternative PFAS, in human plasma and serum. The samples underwent a simple, single-step protein precipitation procedure and were analyzed with a user-friendly LC-MS\/MS method. Method accuracy and precision were evaluated with fortified fetal bovine serum. In addition, the method\u2019s suitability for real-world samples was confirmed by accurately measuring targeted PFAS with known concentrations in NIST standard reference human plasma (NIST SRM 1950) and serum (NIST SRM 1957).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Structures of C1 to C3 PFAS<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45267_9445de-47 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45267_9445de-47\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"689\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-1024x689.jpg\" alt=\"\" class=\"kb-img wp-image-19120\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-1024x689.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-300x202.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-768x517.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-1536x1033.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Experimental<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Plasma and Serum Samples<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Since PFAS-free human plasma and serum were not found during the screening of commercially obtained samples, charcoal-stripped fetal bovine serum (FBS) obtained from MilliporeSigma (Burlington, MA) was used as the blank matrix for method verification because it did not contain any of the analytes of interest except for TFA. To compensate for this, a TFA isotope, <sup>13<\/sup>C-TFA, was employed as a surrogate to assess method accuracy for TFA in FBS. NIST SRM 1950 (metabolites in human plasma) and NIST SRM 1957 (organic contaminants in non-fortified human serum) were purchased from NIST Store (Gaithersburg, MD). These SRMs are characterized by known concentrations of six or seven short-chain and long-chain PFAS.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Standard and Sample Preparation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">TFA is commonly present in laboratory materials, such as pipette tips, glass and polypropylene HPLC vials, and polypropylene tubes. Following a comprehensive examination, the materials with the lowest TFA contamination levels were chosen for standard and sample preparation. Additionally, deionized water and reverse osmosis (RO) water generated at Restek were assessed to determine if they contained PFAS. The results revealed that RO water was free of PFAS contamination, with the exception of TFA, which was found to be present at very low levels. Consequently, RO water was used for the preparation of mobile phase and calibration standards.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The calibration standard solutions (100 \u00b5L) were prepared in RO water, supplemented with 1x phosphate-buffered saline (PBS), across a range of 0.05 to 40 ng\/mL (ppb) in polypropylene HPLC vials. Initial testing revealed that early eluting compounds displayed slightly broader peak shapes in the human plasma and serum samples compared to the neat standard solutions prepared in 100% water. Therefore, PBS was incorporated into the standard solutions to mitigate this variability and ensure uniform chromatographic performance between standard and sample solutions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Five isotopically labeled PFAS were used as quantitative internal standards (QIS) (Table I). A 5 \u00b5L aliquot of QIS working solution (40 ng\/mL of <sup>13<\/sup>C<sub>3<\/sub>-PFBA; 20 ng\/mL of <sup>13<\/sup>C<sub>2<\/sub>-PFHxA and <sup>13<\/sup>C<sub>4<\/sub>-PFOA; and 10 ng\/mL of <sup>13<\/sup>C<sub>5<\/sub>-PFNA and <sup>13<\/sup>C<sub>2<\/sub>-PFDA) was added to the standard solutions, which were then mixed with 200 \u00b5L of methanol containing 1.5% formic acid.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For the assessment of method accuracy and precision, 100 \u00b5L aliquots of FBS were fortified at 0.4, 2, 10, and 30 ppb with non-labeled PFAS and isotopically labeled <sup>13<\/sup>C-TFA, which served as a surrogate for the determination of TFA recovery. The fortified FBS samples were mixed with 5 \u00b5L of QIS working solution and 2 \u00b5L of extracted internal standard (EIS) working solution (50 ng\/mL of <sup>13<\/sup>C<sub>3<\/sub>-PFPrA, <sup>13<\/sup>C<sub>4<\/sub>-PFBA, <sup>13<\/sup>C<sub>5<\/sub>-PFPeA, <sup>13<\/sup>C<sub>5<\/sub>-PFHxA, <sup>13<\/sup>C<sub>4<\/sub>-PFHpA, <sup>13<\/sup>C<sub>8<\/sub>-PFOA, <sup>13<\/sup>C<sub>9<\/sub>-PFNA, <sup>13<\/sup>C<sub>6<\/sub>-PFDA, <sup>13<\/sup>C<sub>3<\/sub>-PFHxS, and <sup>13<\/sup>C<sub>8<\/sub>-PFOS). A 200 \u00b5L aliquot of methanol containing 1.5% formic acid was then added to the fortified FBS samples followed by vortexing for 30 seconds at 3000 rpm. After centrifugation at 4200 rpm for 10 minutes, approximately 150 \u00b5L of supernatant was transferred to a polypropylene vial insert (cat.# 24518), placed in a glass HPLC vial (cat.# 24626), and subsequently injected for LC-MS\/MS analysis. This single-step protein precipitation in clean polypropylene HPLC vials was used to minimize background PFAS contamination and to ensure accurate measurement of target analytes. Non-fortified human plasma and serum samples were also prepared using the same procedure that was used for the fortified FBS samples.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Analytical System<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS analysis was performed by LC-MS\/MS under the conditions shown below. A PFAS delay column was installed between the mixer and injector to prevent any potential PFAS contamination upstream of the injector from coeluting with PFAS in the samples.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">System: Waters ACQUITY UPLC I-Class and Xevo TQ-S triple quadrupole mass spectrometer&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Columns:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Analytical column: Ultra IBD, 100 mm x 2.1 mm, 3 \u00b5m (cat.# 9175312)<\/li>\n\n\n\n<li>PFAS delay column (cat.# 27854)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Injection volume: 5 \u00b5L<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mobile phase A: 5 mM ammonium formate, 0.1% formic acid in water<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mobile phase B: Acetonitrile<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Flow rate: 0.3 mL\/min<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Temperature: 40 \u00b0C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Gradient:&nbsp;&nbsp;<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table style=\"border-style: none; width: auto;\">\n<tbody>\n<tr>\n<td><strong>Time (min)<\/strong><\/td>\n<td><strong>%B<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0.00<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>7.00<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>9.00<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>9.01<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>11.00<\/td>\n<td>20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\">Ion mode: Negative ESI<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mode: Scheduled MRM<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Results and Discussion<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">LC-MS\/MS Method Development<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">After exploring various mobile phases and chromatographic conditions, a final method (Figure 2) was established for the analysis of C1 to C10 PFAS in human plasma and serum. The polar embedded Ultra IBD column provided strong retention and good separation of early eluting, ultrashort-chain PFAS analyzed under reversed-phase conditions. More important, the extensive retention of ultrashort-chain PFAS, especially for the first-eluted analyte (TFA), led to reduced matrix interferences. Matrix impact was further minimized by using stable isotopes as internal standards to correct for any matrix interference during quantification. The MS\/MS transition parameters and internal standards used for each analyte are provided in Table I.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Analysis of a 10 ppb PFAS Standard\u00a0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0812.png\" alt=\"Simultaneous Analysis of C1 to C10 PFAS and Alternative Compounds on Ultra IBD\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0812<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Ultra IBD  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9175312\" rel=\"noopener\">cat.# 9175312<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>3 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>100 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>PFAS 28 calibration standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30734\" rel=\"noopener\">cat.# 30734<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>1:2 water:methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 5 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.3<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>7.00<\/td><td>0.3<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>9.00<\/td><td>0.3<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>9.01<\/td><td>0.3<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>11.00<\/td><td>0.3<\/td><td>80<\/td><td>20<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>275 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ-S<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY UPLC I-Class<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>The standard solution (100 \u03bcL) was prepared in reverse osmosis water supplemented with 1x phosphate-buffered saline at 10 ng\/mL (ppb) in a polypropylene HPLC vial followed by mixing with 200 \u03bcL of methanol containing 1.5% formic acid.     <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>A PFAS delay column (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/27854\" rel=\"noopener\">cat.# 27854<\/a>) was installed before the injector. The peaks of confirmation ions are not displayed in this chromatogram. <\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30734<\/li><li>9175312<\/li><li>27854<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS Biomonitoring<\/li><li>Ultrashort-Chain<\/li><li>pfas-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0812.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> MS Transitions and Analytes Retention Times&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Compounds<\/span><\/strong><\/td><td><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Retention Time (min)<\/span><\/span><\/strong><\/td><td><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Precursor Ion<\/span><\/span><\/strong><\/td><td><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Product Ions*<\/span><\/span><\/strong><\/td><td><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Cone (V)<\/span><\/span><\/strong><\/td><td><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Collision (V)<\/span><\/span><\/strong><\/td><td><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Quantification Internal Standard<\/span><\/span><\/strong><\/td><\/tr><tr><td colspan=\"7\"><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Target Analytes<\/span><\/span><\/strong><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">TFA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.25<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">113.03 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">69.01<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPrA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.81<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">162.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">119.02<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFBA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">5.80<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">213.03 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">168.98<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">14<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPeA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6.56<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">262.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">218.97<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHxA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.13<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">313.10 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">268.97\/118.99<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8\/20<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHpA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.62<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">363.16 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">319.09\/169.06<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10\/18<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFOA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">413.10 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">368.96\/168.90<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10\/16<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFNA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.62<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">463.10 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">419.01\/219.02<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10\/16<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>5<\/sub><\/span><span class=\"font5\">-PFNA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFDA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">9.29<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">513.17 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">469.16\/219.06<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">12\/16<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFDA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">TFMS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.37<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">148.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.93\/98.92<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">62<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">18\/18<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFEtS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">5.44<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">198.90 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.92\/98.91<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">38<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">22\/22<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPrS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6.08<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">248.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.92\/98.91<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">24\/24<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFBS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6.55<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">298.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.97\/98.89<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">26\/26<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPeS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6.93<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">349.10 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.98\/98.98<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">32\/30<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHxS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.24<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">398.90 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.97\/98.89<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">56<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">32\/34<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHpS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.56<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">449.17 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.98\/98.97<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">42\/38<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFOS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.82<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">499.03 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.92\/98.90<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">40\/40<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFNS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.09<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">549.10 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.92\/98.83<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">12<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">42\/40<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFDS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.32<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">599.17 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.98\/98.83<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">44\/46<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>5<\/sub><\/span><span class=\"font5\">-PFNA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">HFPO-DA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.01<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">285.03 [M-COOH]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">169.02\/185.02<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6\/16<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">ADONA<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.11<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">376.90 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">250.93\/84.97<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">22<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">12\/26<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">9Cl-PF3ONS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.75<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">530.78 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">350.85\/82.96<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">12<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">26\/24<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">11Cl-PF3OUdS<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.15<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">630.78 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">450.80\/82.95<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">26\/32<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>5<\/sub><\/span><span class=\"font5\">-PFNA<\/span><\/span><\/span><\/td><\/tr><tr><td colspan=\"7\"><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Extracted Internal Standards<\/span><\/span><\/strong><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFPrA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.81<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">165.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">120.96<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">11<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">5.80<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">217.03 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">171.98<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>5<\/sub><\/span><span class=\"font5\">-PFPeA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6.56<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">267.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">222.99<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>5<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.13<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">318.03 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">272.93<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFHpA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.62<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">366.90 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">321.93<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>8<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">420.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">375.94<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>9<\/sub><\/span><span class=\"font5\">-PFNA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.62<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">471.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">426.87<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>5<\/sub><\/span><span class=\"font5\">-PFNA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>6<\/sub><\/span><span class=\"font5\">-PFDA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">9.29<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">518.90 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">473.87<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">13<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFDA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFHxS<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.24<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">401.90 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.97<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">32<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>8<\/sub><\/span><span class=\"font5\">-PFOS<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.82<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">506.84 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">79.97<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">48<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><\/tr><tr><td colspan=\"7\"><strong><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Quantitative Internal Standards<\/span><\/span><\/strong><\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>3<\/sub><\/span><span class=\"font5\">-PFBA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">5.80<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">215.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">171.97<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td>&nbsp;<\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFHxA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.13<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">314.97 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">269.93<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td>&nbsp;<\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>4<\/sub><\/span><span class=\"font5\">-PFOA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.10<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">416.87 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">371.88<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td>&nbsp;<\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>5<\/sub><\/span><span class=\"font5\">-PFNA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8.62<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">467.87 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">422.89<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">16<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td>&nbsp;<\/td><\/tr><tr><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C<\/span><span class=\"font6\"><sub>2<\/sub><\/span><span class=\"font5\">-PFDA<\/span><\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">9.29<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">514.87 [M-H]-<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">469.84<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">8<\/span><\/span><\/td><td><span style=\"mso-bookmark: _Hlk166838870;\"><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/span><\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Quantifier ion\/qualifier ion. No qualifier ion was used for TFA, PFPrA, PFBA, and PFPeA because only one product ion could be identified for each.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Linearity<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">With quadratic regression (1\/x weighted), all analytes showed acceptable linearities with r<sup>2<\/sup>&nbsp;&gt;0.995 and deviations &lt;20%. Table II shows the specific linear range for each analyte, ranging from 0.05 ppb to 40 ppb, with variation occurring at the lowest calibration concentration.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Accuracy and Precision<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Accuracy and precision for most analytes were assessed at 0.4, 2, and 10 ppb. However, for HFPO-DA and TFA, the evaluation was conducted at 2, 10, and 30 ppb because 0.4 ppb was below the linear range of these compounds. Three batches of samples were prepared and analyzed on different days, totaling nine replicates at each fortification level. The average recoveries and relative standard deviations (%RSD) are presented in Table II. All analytes exhibited recovery values within the range of 82.3\u2013115% across the three fortification levels. Satisfactory method precision was demonstrated with %RSD values ranging from 0.965 to 11.3%. Additionally, the results indicated that all EIS had recovery values within 20% of the nominal concentration. The use of EIS as an additional quality control measure enhanced the reliability and robustness of the method.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Based on the results of the accuracy and precision experiments, the method LOQ was set as the lowest concentration of the standard calibration curve for each analyte. The method LOD was estimated from the analysis of fortified FBS and was defined by a peak signal-to-noise ratio of 3:1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Measurement of C1\u2013C10 and Alternative PFAS in NIST 1950 and 1957 SRMs<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Six preparations of each SRM were analyzed with the developed LC-MS\/MS method. The results indicated that all measured EIS concentrations fell within 20% of the nominal concentration. Moreover, Table III illustrates that the average experimental concentrations of most PFAS closely matched the reference concentrations, with deviations within 20%. Although the measured PFDA concentration in NIST SRM 1957 exhibited a slightly higher deviation of 26%, it remained within the deviation range of the reference concentration. These results demonstrated that the established method was suitable for accurate measurement of PFAS\u2014including ultrashort-chain PFAS\u2014in both human plasma and serum samples. In addition to the reference PFAS, other measurable PFAS were also reported in Table III.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong>&nbsp;Linearity, LOD, Accuracy, and Precision Results for Fortified Fetal Bovine Serum Samples<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&nbsp;<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&nbsp;<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&nbsp;<\/span><\/strong><\/td><td colspan=\"4\"><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Average Recovery (%RSD)<\/span><\/strong><\/td><\/tr><tr><td><strong>&nbsp;<\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Linearity Range<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">LOD<\/span><\/strong><\/td><td colspan=\"4\"><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Fortified Concentration (ng\/mL)<\/span><\/strong><\/td><\/tr><tr><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Analytes<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">(ng\/mL)<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">(ng\/mL)<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.4<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">30<\/span><\/strong><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"><sup>13<\/sup><span class=\"font5\">C-TFA<\/span><\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.50 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.1250*<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">90.6 (9.28)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">98.0 (2.99)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">100 (10.7)<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPrA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.25 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0102<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">108 (2.53)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">115 (0.965)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">105 (6.99)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFBA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0222<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">104 (5.57)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">109 (1.75)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">104 (1.51)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPeA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0125<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">97.4 (3.25)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">93.3 (4.19)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">89.1 (5.57)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHxA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0098<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">99.2 (2.46)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">109 (4.65)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">102 (6.31)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHpA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0050<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">86.7 (5.37)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">99.2 (2.04)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">89.2 (1.80)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFOA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0051<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">94.8 (8.24)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">107 (5.30)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">95.6 (3.35)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFNA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0012<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">96.2 (1.44)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">111 (1.87)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">99.1 (2.62)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFDA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0083<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">93.6 (1.93)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">102 (2.03)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">95.5 (3.64)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">TFMS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.05 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0070<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">89.4 (7.33)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">88.8 (3.80)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">91.9 (3.19)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFEtS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.05 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0020<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">98.0 (2.62)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">103 (1.47)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">99.3 (2.26)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPrS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.05 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0030<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">98.1 (8.18)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">108 (4.23)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">98.9 (4.15)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFBS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.05 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0124<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">88.0 (8.84)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">94.1 (4.95)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">86.5 (6.17)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPeS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0031<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">94.8 (4.57)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">100 (8.05)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">94.3 (5.43)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHxS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0115<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">85.8 (7.88)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">96.0 (10.0)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">92.2 (8.98)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHpS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0088<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">92.5 (6.75)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">99.8 (6.45)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">93.4 (5.74)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFOS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0200<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">97.8 (8.66)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">97.9 (7.01)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">95.9 (3.37)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFNS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0129<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">92.1 (7.98)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">94.2 (4.43)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">91.9 (2.78)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFDS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0111<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">92.6 (8.20)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">82.3 (3.48)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">87.6 (3.55)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">HFPO-DA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.50 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.1875<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">99.9 (11.3)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">91.1 (8.95)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">90.4 (6.13)<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">ADONA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0035<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">90.4 (7.14)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">106 (4.67)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">95.7 (4.25)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">9Cl-PF3ONS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0031<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">95.8 (4.20)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">93.7 (5.12)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">93.8 (6.71)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">11Cl-PF3OUdS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10 &#8211; 40<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.0023<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">106 (5.10)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">84.5 (4.20)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">97.2 (4.86)<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*For non-labeled TFA<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong>&nbsp;Quantification of PFAS in NIST 1950 and 1957 SRMs<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Analytes<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Reference<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Experimental Avg.<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Experimental Precision (%RSD)<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Relative Concentration (%)**<\/span><\/strong><\/td><\/tr><tr><td><strong>&nbsp;<\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Conc. (ng\/mL)<\/span><\/strong><\/td><td><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">Conc. (ng\/mL)<\/span><\/strong><\/td><td><strong>&nbsp;<\/strong><\/td><td><strong>&nbsp;<\/strong><\/td><\/tr><tr><td colspan=\"5\"><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">NIST SRM 1950<\/span><\/strong><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFOA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.27 \u00b1 0.06<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.12<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.70<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">95.4<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFNA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.720 \u00b1 0.028<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.85<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.74<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">117<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFDA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.322 \u00b1 0.007<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.30<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.47<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">91.6<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHxS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.25 \u00b1 0.08<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2.91<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6.26<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">89.5<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFOS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">10.64 \u00b1 0.13<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">12.57<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2.92<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">118<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">TFA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">5.74<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.45<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPrA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.26<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6.90<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHpA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.23<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.04<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">TFMS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.08<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.95<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPeS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.15<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.31<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHpS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.36<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.90<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFDS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.64<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td colspan=\"5\"><strong><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">NIST SRM 1957*<\/span><\/strong><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHpA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.305 \u00b1 0.051<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.28<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2.16<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">92.1<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFOA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">5.00 \u00b1 0.44<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.21<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">1.91<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">84.2<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFNA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.878 \u00b1 0.077<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.77<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">1.38<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">87.9<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFDA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.39 \u00b1 0.12<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.29<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">2.69<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">74.4<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHxS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.00 \u00b1 0.83<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.35<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">9.88<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">83.8<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFOS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">21.1 \u00b1 1.3<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">20.46<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.81<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">97.0<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">TFA<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.22<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">3.79<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">TFMS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.07<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFPeS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">7.97<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFHpS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.48<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">6.20<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><tr><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">PFDS<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">0.10<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">4.23<\/span><\/td><td><span style=\"mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\">&#8211;<\/span><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*The reference concentration for NIST SRM 1957 is presented as mass fraction (\u00b5g\/kg).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">**Relative concentration = (experimental concentration\/reference concentration) x 100<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Future Directions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">While the data reported here were generated using a standard, stainless-steel Ultra IBD column (cat.# 9175312), the same column (stationary phase and dimensions) is now available in an inert hardware format (Ultra IBD Inert, cat.# 9175312-T). &nbsp;The hardware used to make the Ultra IBD Inert column is treated with an inert coating, which improves sensitivity by preventing unwanted analyte interactions with the stainless-steel surface. &nbsp;As shown in Figure 3, the inert hardware results in a notable enhancement in detection sensitivity for most of the PFAS tested (3-70% increase in peak area and 5-75% increase in peak height) compared to columns made with uncoated hardware. Future applications of the method developed here may benefit from using an Ultra IBD Inert column, particularly for samples containing PFAS at trace levels.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0Inert LC column hardware increased peak area and height for most PFAS compared to columns made with traditional stainless-steel hardware.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45267_14e76d-01 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45267_14e76d-01\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"760\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-03-760x1024.jpg\" alt=\"\" class=\"kb-img wp-image-19126\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-03-760x1024.jpg 760w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-03-223x300.jpg 223w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-03-768x1035.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-03-1140x1536.jpg 1140w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-03-1520x2048.jpg 1520w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-03.jpg 1800w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusions<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A simple, reliable workflow was established in this study to incorporate ultrashort-chain PFAS analysis into a method that also included longer-chain PFAS that are commonly monitored in human plasma and serum. The method utilized a polar-embedded Ultra IBD column to increase chromatographic retention of these small polar analytes, and the results demonstrated that the method was rugged, accurate, and precise. Most important, this method can offer a valuable tool for gaining insights into human exposure to these emergent ultrashort-chain PFAS. Visit&nbsp;<a href=\"https:\/\/www.restek.com\/pages\/your-partner-in-pfas-analysis\" target=\"_blank\" rel=\"noopener\">www.restek.com\/PFAS<\/a>&nbsp;for additional products, methods, and technical resources.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9175312\">                                \u8d27\u53f7\uff1a 9175312                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ultra IBD, 3 \u00b5m, 100 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9175312\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9175312-T\">                                \u8d27\u53f7\uff1a 9175312-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ultra IBD Inert, 3 \u00b5m, 100 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9175312-T\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u8d27\u53f7\uff1a 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS Delay Column, 5 \u00b5m, 50 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24626\">                                \u8d27\u53f7\uff1a 24626                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Big Mouth Step Screw-Thread Vials with Grad Marking Spot, 2 mL, 12 x 32 mm, 10 mm\/425 Thread (Vial Only), Clear, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24626\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30734\">                                \u8d27\u53f7\uff1a 30734                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS 28 Calibration Standard, 1 \u00b5g\/mL, Methanol (1 mM KOH), 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30734\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24518\">                                \u8d27\u53f7\uff1a 24518                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Polypropylene, Big Mouth w\/Bottom Spring, 250 \u00b5L, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24518\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_3b9a6b-09{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_3b9a6b-09 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id99903_b5fa4b-ad{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id99903_b5fa4b-ad alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column99903_2824bd-5d > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_2824bd-5d{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_2824bd-5d\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading99903_df06fd-cb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading99903_df06fd-cb\"><span class=\"kb-adv-text-inner\">\u60a8\u7684PFAS\u5206\u6790\u9700\u8981\u5e2e\u52a9\u5417\uff1f<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">\u4ece\u65b9\u6cd5\u9009\u62e9\u5230\u4ea7\u54c1\u63a8\u8350\uff0cRestek PFAS \u4e13\u5bb6\u52a9\u60a8\u5e94\u5bf9\u590d\u6742\u5206\u6790\u6d41\u7a0b\uff0c\u83b7\u5f97\u51c6\u786e\u3001\u53ef\u9760\u7684\u5206\u6790\u7ed3\u679c\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns99903_bac608-3f{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns99903_bac608-3f .kt-button{font-weight:normal;font-style:normal;}.kt-btns99903_bac608-3f .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns99903_bac608-3f\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn99903_980c0c-c6.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn99903_980c0c-c6.kb-button:hover .kb-svg-icon-wrap, .kb-btn99903_980c0c-c6.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn99903_980c0c-c6 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/explore.restek.com\/PFAS\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Contact a PFAS<\/strong> <strong>expert<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Short- and long- chain (C4 to C10) PFAS are routinely measured in human plasma and serum to determine exposure levels and assess potential health risks. This method incorporates ultrashort-chain PFAS, allowing the simultaneous analysis of C1 to C10 compounds.<\/p>\n","protected":false},"author":46,"featured_media":6403,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[784],"tags":[2782],"industries-application":[2153,2156,2165],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2299,2302],"ppma_author":[578,702],"class_list":["post-45267","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-it","tag-pfas","industries-application-clinical","industries-application-clinical-toxicology","industries-application-pfas-testing","resource-technique-liquid-chromatography","resource-technique-ms-ms"],"acf":[],"taxonomy_info":{"category":[{"value":784,"label":"Application Notes"}],"post_tag":[{"value":2782,"label":"PFAS"}],"industries-application":[{"value":2153,"label":"Clinical"},{"value":2156,"label":"Clinical Toxicology"},{"value":2165,"label":"PFAS Testing"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2302,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFAN4273-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Shun-Hsin Liang, PhD","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/shun-hsin-liang-phd\/"},"comment_info":0,"category_info":[{"term_id":784,"name":"Application Notes","slug":"application-notes-it","term_group":0,"term_taxonomy_id":784,"taxonomy":"category","description":"","parent":0,"count":86,"filter":"raw","cat_ID":784,"category_count":86,"category_description":"","cat_name":"Application Notes","category_nicename":"application-notes-it","category_parent":0}],"tag_info":[{"term_id":2782,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2782,"taxonomy":"post_tag","description":"","parent":0,"count":126,"filter":"raw"}],"authors":[{"term_id":578,"user_id":46,"is_guest":0,"slug":"shun-hsin-liang-phd","display_name":"Shun-Hsin Liang, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-liang-shun-hsin-e1765414149534.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-liang-shun-hsin-e1765414149534.png"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Shun-Hsin","last_name":"Liang","user_url":"https:\/\/www.linkedin.com\/in\/shun-hsin-liang-174423123\/","job_title":"Senior Principal Scientist, LC Solution","description":"Shun-Hsin is a senior principal scientist in LC Solutions at Restek. He received his bachelor\u2019s degree from the National Taiwan University in 1988 and obtained his PhD from Michigan State University in 1996. He performed postdoctoral research at the University of Michigan from 1996 to 2000 for oncology studies. In 2001, he was appointed as research faculty at The Pennsylvania State University and focused on molecular toxicology research. In 2006, he joined MPI Research Inc. as a senior research scientist and was a study director for GLP analytical projects. In 2013, Dr. Liang joined the LC Solutions department at Restek and specialized in developing application methods across the fields of environmental, food safety, and life sciences."},{"term_id":702,"user_id":0,"is_guest":1,"slug":"justin-steimling","display_name":"Justin Steimling","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Justin","last_name":"Steimling","user_url":"https:\/\/www.linkedin.com\/in\/justin-steimling-959729167\/","job_title":"R&D, LC Solutions","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/46"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=45267"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45267\/revisions"}],"predecessor-version":[{"id":100251,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/45267\/revisions\/100251"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media\/6403"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=45267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=45267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=45267"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=45267"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=45267"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=45267"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=45267"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=45267"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=45267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}