{"id":51624,"date":"2018-02-22T13:30:00","date_gmt":"2018-02-22T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/cannabis-concentrates-part-ii-were-heading-to-space\/"},"modified":"2025-10-28T18:24:35","modified_gmt":"2025-10-28T18:24:35","slug":"cannabis-concentrates-part-ii-were-heading-to-space","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/blogs\/gnbl4601\/cannabis-concentrates-part-ii-were-heading-to-space","title":{"rendered":"Cannabis Concentrates Part II: We&#8217;re Heading to Space!"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Welcome back! It\u2019s been a little while since my last blog, but in that time, we\u2019ve been doing some interesting things regarding cannabis research. Last time, I discussed that we would be analyzing residual solvents in cannabis concentrates and today, I\u2019m going to show one of the methods that we\u2019ve been working on.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before we get into the sample preparation techniques that we\u2019ve been focusing on, let\u2019s go over some initial things. First, we need to select a column that has the capability of resolving these light weight, volatile compounds (see Table 1). An easy way to do this is through Restek\u2019s\u00a0<a href=\"https:\/\/ez.restek.com\/proezgc\/row\" target=\"_blank\" rel=\"noreferrer noopener\">Pro\u00a0<em>EZGC\u00a0<\/em>Chromatogram Modeler<\/a>. After placing our compound list into\u00a0<em>EZGC<\/em>, we saw that the program gave us numerous selections with the first column being the Rtx-502.2. However, since our future work includes terpene analysis, we decided to go with the Rxi-624Sil MS, 30 m x 0.25 mm x 1.40 \u00b5m (cat. # 13868). This column has better high temperature stability and it also lines up perfectly with what Amanda chose for her method using Full Evaporation Technique (FET).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-cannabis-concentrates-part-ii-were-heading-to-space-01.png\" alt=\"chart\" class=\"wp-image-45048\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Now that we have our column selected, we can move on to the main event! When thinking about how to approach this problem (analyzing residual solvents) we started out by using Jason Herrington\u2019s favorite method: KISS. For those who haven\u2019t heard of KISS, it stands for Keep It Simple, Stupid (sorry, no Gene Simmons here). We wanted to keep everything as simple as possible to make your life in the lab as stress free as possible. To do that, we thought that&nbsp;the easiest approach to this analysis would be through headspace (HS). Headspace samples are prepared by taking a sample and adding it to a dilution solvent in a HS vial (we\u2019re using a 20 mL vial). Depending on the analytes of interest, an inorganic salt (Sodium Chloride, Sodium Sulfate, etc.) can be added to the vial as well to help lower the partitioning coefficient of the more polar compounds. For more information on HS analysis, please check out Restek\u2019s Headspace Technical Guide!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In our current method, which we will call HS-Syringe-GC-MS, we are taking the headspace from a 6 mL sample. All standards (STDs) were prepared as follows: 3 g sodium chloride (NaCl) was measured into a 20 mL amber headspace vial (cat. # 23086) with screw top cap (cat. # 23090). 6 mL of deionized (DI) water was then added to the vial. All STDs then received internal standards. Lastly, STDs were capped and vortexed at 3000 rpm for 10 seconds, inverted, then vortexed again for 10 seconds at 3000 rpm. Luckily for us, we are using the CTC PAL RTC rail system, so the vial equilibration and injection are automated. Once equilibrated, 500 \u00b5L of the headspace is drawn into a gastight syringe and injected into the gas chromatograph.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*Note: If you are not using a rail system, don\u2019t fret! This method can easily be done with a manual setup.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For more detailed specs, please refer to Table 2 &amp; 3, which has our rail and GC-MS parameters.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-cannabis-concentrates-part-ii-were-heading-to-space-02.png\" alt=\"table\" class=\"wp-image-45053\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Now that we\u2019ve gone over how we are preparing our samples, let\u2019s take a look at the chromatography (Figures 1 &amp; 2):<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-cannabis-concentrates-part-ii-were-heading-to-space-03.png\" alt=\"diagram\" class=\"wp-image-45332\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">This total ion chromatogram (TIC, Figure 1) shows that we are able to resolve all 19 compounds of interest. Some of the polar compounds that have higher partitioning coefficients are a little more difficult to see. However, in the extracted ion chromatogram (EIC, Figure 2), you can see that we were in-fact able to drive them out of the water and into the headspace. The only compounds that are not baseline resolved are the Toluene-d8 and Toluene. The resolution value for these two compounds is 1.38, which is resolved enough for accurate integration. Since Toluene-d8 is our internal standard, we\u2019ll probably be changing our internal standard in the near future, so that Toluene is completely baseline resolved.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-cannabis-concentrates-part-ii-were-heading-to-space-04.png\" alt=\"chart, histogram\" class=\"wp-image-45090\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">I know we threw a lot at you here, so I think this is a good place to take a break! We do have more to show you, but we don\u2019t want to give it to you all at once. We want to leave you hungry for more! To recap, we were able to take a very simple approach to this analysis by using the HS-Syringe technique and with the help of<em>&nbsp;EZGC<\/em>, we were able to resolve all of our compounds with hardly any difficulty. In addition, this method can also be done with a manual HS-Syringe and run on a GC-FID. Like I said, we have much more to cover, so stay tuned for our other HS approach in our next blog!<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13868\">                                \u8d27\u53f7\uff1a 13868                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-624Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 1.40 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13868\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23086\">                                \u8d27\u53f7\uff1a 23086                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Headspace Screw-Thread Vials, 18 mm, 20 mL, Amber, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23086\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23090\">                                \u8d27\u53f7\uff1a 23090                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Magnetic Screw-Thread Headspace Caps, 18 mm and Blue PTFE\/Silicone, 1.5 mm thick Septa for SPME, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23090\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Welcome back! It&rsquo;s been a little while since my last blog, but in that time, we&rsquo;ve been doing some interesting things regarding cannabis research. Last time, I discussed that we would be analyzing residual solvents in cannabis concentrates and today,&#8230;<\/p>\n","protected":false},"author":32,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[2149,2151],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2294,2296,2298,2301],"ppma_author":[452],"class_list":["post-51624","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-cannabis","industries-application-medical-or-recreational-cannabis","resource-technique-gas-chromatography-gc","resource-technique-headspace","resource-technique-injection-techniques","resource-technique-mass-spectrometry-ms"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"industries-application":[{"value":2149,"label":"Cannabis"},{"value":2151,"label":"Medical or Recreational Cannabis"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2296,"label":"Headspace"},{"value":2298,"label":"Injection Techniques"},{"value":2301,"label":"Mass Spectrometry (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Colton Myers","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/colton-myers\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51624","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=51624"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51624\/revisions"}],"predecessor-version":[{"id":58743,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51624\/revisions\/58743"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=51624"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=51624"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=51624"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=51624"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=51624"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=51624"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=51624"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=51624"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=51624"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}