{"id":51699,"date":"2013-02-28T13:30:00","date_gmt":"2013-02-28T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/half-the-column-same-chromatogram-trimming-your-gc-column-and-maintaining-resolution\/"},"modified":"2025-10-29T16:11:46","modified_gmt":"2025-10-29T16:11:46","slug":"half-the-column-same-chromatogram-trimming-your-gc-column-and-maintaining-resolution","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/blogs\/gnbl4686\/half-the-column-same-chromatogram-trimming-your-gc-column-and-maintaining-resolution","title":{"rendered":"Half the Column, Same Chromatogram. Trimming your GC Column and Maintaining Resolution."},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Oftentimes, when dealing with complex matrices that have a lot of non-volatile material, you may need to trim the front end of your column to prolong the column lifetime. &nbsp;I was recently working on a project where I wanted to see how short of a column I could use and still maintain resolution between some isobaric pairs of brominated diphenyl ethers (BDE 49 and BDE 71).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I started with a&nbsp;15m x 0.25mm x 0.10\u00b5m Rtx-1614&nbsp;column and GC instrument conditions that were optimized by&nbsp;Pro ezGC.&nbsp; I began trimming loops off of the front of the column and accurately measured the new column length by injecting air into my GC-MS to determine the holdup time.&nbsp; Then, I used the Agilent GC pressure\/flow calculator to decrease the column length until the calculated holdup time matched my experimental holdup time.&nbsp; This new column length was used in the&nbsp;Agilent GC Method Translator software&nbsp;to calculate my new method.&nbsp; By doing this the analytes are eluting from the column at the same temperature, no matter what column length we use.&nbsp; This provides essentially identical chromatograms and maintains resolution (See figure below).&nbsp; I think I could have continued trimming my column, but I ran into two issues.&nbsp; First, my head pressure was reaching 0psi because I was operating under vacuum outlet conditions.&nbsp; Second, the oven ramp rate was getting so fast that my instrument couldn\u2019t properly keep up.&nbsp; Really this just goes to show that you can trim your column in half (and the run time!), while still maintaining resolution, by properly translating the method.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In order to translate your methods remember the following things:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Measure new column length using holdup time<\/li>\n\n\n\n<li>Input new column length and all original conditions into method translator (select translate only)<\/li>\n\n\n\n<li>Make sure to change ALL parameters necessary of new translated method (including your new column length) into GC software<\/li>\n\n\n\n<li>Check your instrument maximum heating rate to make sure your instrument can keep up to new method conditions.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"804\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-half-the-column-same-chromatogram.-trimming-your-gc-column-and-maintaining-resolution.-01-1024x804.jpg\" alt=\"\" class=\"wp-image-14764\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-half-the-column-same-chromatogram.-trimming-your-gc-column-and-maintaining-resolution.-01-1024x804.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-half-the-column-same-chromatogram.-trimming-your-gc-column-and-maintaining-resolution.-01-300x236.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-half-the-column-same-chromatogram.-trimming-your-gc-column-and-maintaining-resolution.-01-768x603.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-half-the-column-same-chromatogram.-trimming-your-gc-column-and-maintaining-resolution.-01.jpg 1425w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The resolution between BDE 49 and BDE 71 is maintained while trimming the column almost in half. The analysis time is also cut in half!<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/10296\">                                \u8d27\u53f7\uff1a 10296                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-1614 GC Capillary Column, 15 m, 0.25 mm ID, 0.10 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/10296\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Oftentimes, when dealing with complex matrices that have a lot of non-volatile material, you may need to trim the front end of your column to prolong the column lifetime. I was recently working on a project where I wanted to&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[563],"product-library":[],"resource-technique":[2307,2312],"ppma_author":[600],"class_list":["post-51699","post","type-post","status-publish","format-standard","hentry","category-blogs","resource-type-column-installation-and-care","resource-technique-gas-chromatography-gc-zh","resource-technique-mass-spectrometry-ms-zh"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"resource-type":[{"value":563,"label":"Column Installation and Care"}],"resource-technique":[{"value":2307,"label":"\u6c14\u76f8\u8272\u8c31\uff08GC\uff09"},{"value":2312,"label":"\u8d28\u8c31 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":600,"user_id":0,"is_guest":1,"slug":"michelle-misselwitz","display_name":"Michelle Misselwitz","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Michelle","last_name":"Misselwitz","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=51699"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51699\/revisions"}],"predecessor-version":[{"id":59118,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51699\/revisions\/59118"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=51699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=51699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=51699"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=51699"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=51699"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=51699"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=51699"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=51699"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=51699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}