{"id":51706,"date":"2014-10-30T14:30:00","date_gmt":"2014-10-30T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-dirty-are-you-part-3glovesthe-question\/"},"modified":"2026-01-28T15:54:06","modified_gmt":"2026-01-28T15:54:06","slug":"how-dirty-are-you-part-3glovesthe-question","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/blogs\/gnbl4693\/how-dirty-are-you-part-3glovesthe-question","title":{"rendered":"How Dirty Are You? Part 3\u2026Gloves\u2026The Question"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"360\" height=\"338\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-dirty-are-you-part-3gloves-bulbs-the-question-01.png\" alt=\"boxer posing with his gloves on\" class=\"wp-image-14962\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-dirty-are-you-part-3gloves-bulbs-the-question-01.png 360w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-dirty-are-you-part-3gloves-bulbs-the-question-01-300x282.png 300w\" sizes=\"auto, (max-width: 360px) 100vw, 360px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"296\" height=\"300\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-dirty-are-you-part-3gloves-bulbs-the-question-02.png\" alt=\"vintage photo of a woman wearing long opera gloves\" class=\"wp-image-14968\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">This third installment of <a href=\"https:\/\/discover.restek.com\/blogs\/GNBL4689\/how-dirty-are-you-part-1-parafilm-take-a-quiz\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/blogs\/GNBL4689\/how-dirty-are-you-part-1-parafilm-take-a-quiz\/\"><em>How Dirty Are You?<\/em><\/a> is all about gloves. Outside of solvent compatibility, there is a lot of room for personal preference regarding the type of lab gloves people can use.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I found 5 different gloves in our lab. The bright green gloves and yellow gloves are the two types most often used by my lab mates. I use the bright green gloves. I work with QuEChERS extracts all the time so I was most interested in background resulting from gloves contacting acetonitrile. I have already investigated the bright green gloves when I was tracking down some peaks in my process blank for a QuEChERS experiment. I was seeing some repeating peaks which were identified as alkanes via GC-TOFMS. Through some further investigation, I was able to confirm that these alkane peaks were from my favorite bright green gloves. That got me thinking about contamination peaks from other gloves&#8230;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What We Did<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We tested the background generated by the 5 glove types found in our lab by soaking a small piece of glove in 1 mL of acetonitrile for 30 minutes. The samples were tested via GC-TOFMS after the 30 minutes. For relative intensity, a dashed line at the peak height of a 2 ppm PAH standard is drawn on the chromatograms. <a href=\"https:\/\/discover.restek.com\/blogs\/gnbl4694\/how-dirty-are-you-part-3glovesthe-answers\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/blogs\/gnbl4694\/how-dirty-are-you-part-3glovesthe-answers\">But you will not see the results until my next blog!<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Which gloves (see below) gave the worst background?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bright Green Gloves<\/li>\n\n\n\n<li>Baby Blue Gloves<\/li>\n\n\n\n<li>Yellow latex Gloves<\/li>\n\n\n\n<li>Green Gloves<\/li>\n\n\n\n<li>Royal Blue Gloves<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">2. What common additive was found in multiple gloves tested?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dyes<\/li>\n\n\n\n<li>Antioxidants<\/li>\n\n\n\n<li>UV Stabilizers<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"864\" height=\"768\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-dirty-are-you-part-3gloves-bulbs-the-question-03.png\" alt=\"a series of safety gloves with the types listed\" class=\"wp-image-14974\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-dirty-are-you-part-3gloves-bulbs-the-question-03.png 864w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-dirty-are-you-part-3gloves-bulbs-the-question-03-300x267.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-dirty-are-you-part-3gloves-bulbs-the-question-03-768x683.png 768w\" sizes=\"auto, (max-width: 864px) 100vw, 864px\" \/><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This third installment of How Dirty Are You? is all about gloves. Outside of solvent compatibility, there is a lot of room for personal preference regarding the type of lab gloves people can use.<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2294],"ppma_author":[594],"class_list":["post-51706","post","type-post","status-publish","format-standard","hentry","category-blogs","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":594,"user_id":0,"is_guest":1,"slug":"julie-kowalski","display_name":"Julie Kowalski","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Julie","last_name":"Kowalski","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=51706"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51706\/revisions"}],"predecessor-version":[{"id":85336,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51706\/revisions\/85336"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=51706"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=51706"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=51706"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=51706"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=51706"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=51706"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=51706"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=51706"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=51706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}