{"id":51858,"date":"2024-01-09T00:00:00","date_gmt":"2024-01-09T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma\/"},"modified":"2026-08-11T17:06:43","modified_gmt":"2026-08-11T17:06:43","slug":"which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/blogs\/gnbl4867\/which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma","title":{"rendered":"Which Column is Best for the Analysis of Methylmalonic Acid (MMA)?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">If you search Restek\u2019s website for methylmalonic acid (MMA), you will find two different solutions for this analysis in plasma. One using a Force C18 column (<a href=\"https:\/\/discover.restek.com\/CFAN3010\/evaluation-of-a-simple-method-for-methylmalonic-acid-analysis-in-human-plasma-by-lc-msms\/\">Evaluation of a Simple Method for Methylmalonic Acid Analysis in Human Plasma by LC-MS\/MS<\/a>) and one using a Raptor Polar X column (<a href=\"https:\/\/discover.restek.com\/CFAN3992\/method-for-the-simultaneous-analysis-of-methionine-pathway-metabolites-and-methylmalonic-acid\/\">Method for the Simultaneous Analysis of Methionine Pathway Metabolites and Methylmalonic Acid<\/a>). You might be wondering why this is the case.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For starters, MMA is an important biomarker for a number of cobalamin disorders, however it is not the only biomarker that is looked at for this type of diagnosis. While MMA is analyzed in our Force C18 method, homocysteine, methionine, cystathionine, and cysteine are also important analytes to look at when trying to diagnose cobalamin disorders. In order to provide a more efficient method for our customers, we added these analytes to one method for a more comprehensive test of cobalamin disorders. This method includes a simple sample preparation without derivatization, as well as a rapid 4-minute LC-MS\/MS analysis. A 50 x 2.1 mm, 2.7 \u00b5m Raptor Polar X column with an accompanying Raptor EXP Polar X guard were used for this method.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to the method being more comprehensive on Polar X, the conditions in which these compounds are analyzed enables increased sensitivity of the analytes. While the Force C18 method is effective at retaining MMA and separating its natural occurring isomer, succinic acid, the method utilizes 0.5% formic acid (v\/v) modified mobile phases in order to get MMA in its neutral form so that it can be retained on a traditional reversed-phase column. However, high levels of formic acid are known to suppress analyte response in ESI- mode. By utilizing Polar X, which features a combined HILIC and ion-exchange retention mechanism, retention of MMA can be achieved while in its ionized form which means much less formic acid is needed in the mobile phase resulting in increased sensitivity. In the examples below, both methods used a 5 \u00b5L injection of a 100 ng\/mL sample. You can see that the sensitivity is improved using the Polar X column. This is especially important when working with very low limits of detection and limits of quantitation.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Separation of Succinic Acid and Methylmalonic Acid on a Force C18 Column 100 x 3 mm, 3 \u00b5m<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<table style=\"border-collapse: collapse; width: 100%; border: 1px solid #FFFFFF;\" border=\"1\"><colgroup><col style=\"width: 49.9758%;\"><col style=\"width: 49.9758%;\"><\/colgroup>\n<tbody>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Column:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">Force C18 100 x 3mm, 3 &micro;m (Cat. # 963431E)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Mobile Phase A:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">0.5% Formic Acid in Water<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Mobile Phase B:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">0.5% Formic Acid in Methanol<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Injection Volume:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">5 &micro;L<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Concentration:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">100 ng\/mL<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Flow:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">0.7 mL\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Gradient:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">\n<table style=\"border-collapse: collapse; width: 100%; border-style: none;\" border=\"1\"><colgroup><col style=\"width: 50%;\"><col style=\"width: 50%;\"><\/colgroup>\n<tbody>\n<tr>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\"><strong>Time (min)<\/strong><\/td>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\"><strong>%B<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">0.00<\/td>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">5<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">0.50<\/td>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">60<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">3.00<\/td>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">75<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">3.01<\/td>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">100<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">5.00<\/td>\n<td style=\"text-align: center; border: 1px solid rgb(255, 255, 255);\">STOP<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Column Temp.:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">35&deg;C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n\n<table style=\"border-collapse: collapse; width: 100%; border: 1px solid #FFFFFF;\" border=\"1\"><colgroup><col style=\"width: 33.3008%;\"><col style=\"width: 33.3008%;\"><col style=\"width: 33.3008%;\"><\/colgroup>\n<tbody>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Analyte<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">Retention Time (min)<\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">Peak Height (cps)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Succinic Acid<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">1.67<\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">34500<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Methylmalonic Acid<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">2.03<\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">840000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"522\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-01-1024x522.png\" alt=\"\" class=\"wp-image-17596\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-01-1024x522.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-01-300x153.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-01-768x391.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-01-1536x783.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-01.png 1607w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Separation of Succinic Acid and Methylmalonic Acid on a Raptor Polar X Column 50 x 2.1 mm, 2.7 \u00b5m<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<table style=\"border-collapse: collapse; width: 100%; border: 1px solid #FFFFFF;\" border=\"1\"><colgroup><col style=\"width: 50.0244%;\"><col style=\"width: 49.9756%;\"><\/colgroup>\n<tbody>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Column:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">Raptor Polar X 50 x 2.1 mm, 2.7 &micro;m (Cat. # 9311A52)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Mobile Phase A:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">0.5% Formic Acid in Water<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Mobile Phase B:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">Acetonitrile<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Injection Volume:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">5 &micro;L<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Concentration:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">100 ng\/mL<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Flow:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">0.6 mL\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Gradient:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">\n<table style=\"border-collapse: collapse; width: 100%; border-style: none;\" border=\"1\"><colgroup><col style=\"width: 50.0244%;\"><col style=\"width: 50.0244%;\"><\/colgroup>\n<tbody>\n<tr>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">Time (min)<\/td>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">%B<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">0.00<\/td>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">85<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">1.00<\/td>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">55<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">3.00<\/td>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">10<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">3.01<\/td>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">85<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">4.00<\/td>\n<td style=\"border: 1px solid rgb(255, 255, 255);\">STOP<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Column Temp.:<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">40&deg;C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n\n<table style=\"border-collapse: collapse; width: 100%; border: 1px solid #FFFFFF;\" border=\"1\"><colgroup><col style=\"width: 33.317%;\"><col style=\"width: 33.317%;\"><col style=\"width: 33.317%;\"><\/colgroup>\n<tbody>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Analyte<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">Retention Time (min)<\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">Peak Height (cps)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Succinic Acid<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">1.35<\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">60100<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: rgb(68, 114, 196); border: 1px solid rgb(255, 255, 255);\"><span style=\"color: rgb(255, 255, 255);\">Methylmalonic Acid<\/span><\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">2.95<\/td>\n<td style=\"background-color: rgb(218, 227, 243); border: 1px solid rgb(255, 255, 255);\">1600000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"603\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-02-1024x603.png\" alt=\"\" class=\"wp-image-17602\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-02-1024x603.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-02-300x177.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-02-768x452.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-02-1536x904.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-mma-02.png 1628w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Additionally, the new method on Polar X achieves better resolution of MMA and its naturally occurring isomer, succinic acid. In the original method, these two analytes were separated, but it is clear in the chromatograms above that there is increased resolution between these analytes using Polar X.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">One further consideration for the analysis of MMA is the use of an inert LC column. Because of the chelating properties of MMA, the use of traditional stainless steel column hardware can affect sensitivity and peak shape. When using an inert column for this analysis, peak shape and sensitivity were greatly improved for MMA. An example showing the use of a Force Inert C18 can be found in Figure 3 below.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3: <\/strong>Recovery Comparison of MMA on Traditional vs. Inert LC Column Hardware<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"539\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-03-1024x539.jpg\" alt=\"\" class=\"wp-image-23446\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-03-1024x539.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-03-300x158.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-03-768x404.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-03-1536x809.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-which-column-is-best-for-the-analysis-of-methylmalonic-acid-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Overall, we wanted to create a new method that included more relevant analytes in order to create a more efficient and comprehensive method for our customers. However, if you are only analyzing MMA and feel more comfortable using traditional reversed-phase chromatography, our original method on the Force C18 column still works great! You also have the option of using a Force Inert C18 to improve sensitivity. If you are looking at additional analytes, or looking for better sensitivity or resolution between analytes, the method on the Polar X column may be a better solution for you. If you are interested in trying an inert column, contact your local <a href=\"https:\/\/www.restek.com\/find-sales-rep\" target=\"_blank\" rel=\"noreferrer noopener\">sales representative<\/a>!<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/963431E\">                                \u8d27\u53f7\uff1a 963431E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force C18, 3 \u00b5m, 100 x 3.0 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/963431E\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A52\">                                \u8d27\u53f7\uff1a 9311A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Polar X, 2.7 \u00b5m, 50 x 2.1 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A52\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>If you search Restek&rsquo;s website for methylmalonic acid (MMA), you will find two different solutions for this analysis in plasma. One uses a Force C18 LC column and another a Raptor Polar X column. Why is this the case?<\/p>\n","protected":false},"author":24,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[444],"class_list":["post-51858","post","type-post","status-publish","format-standard","hentry","category-blogs"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}]},"featured_image_src_large":false,"author_info":{"display_name":"Samantha Herbick","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/samantha-herbick\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":444,"user_id":24,"is_guest":0,"slug":"samantha-herbick","display_name":"Samantha Herbick","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herbick-samantha.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herbick-samantha.jpg"},"author_category":"1","first_name":"Samantha","last_name":"Herbick","user_url":"https:\/\/www.linkedin.com\/in\/samantha-herbick-656378136\/","job_title":"Advanced Scientist, LC Solutions","description":"Samantha Herbick is an applications scientist within the LC Solutions Department at Restek. Her primary focus is on the development of applications in the toxicology and life science markets. She attended Duquesne University where she earned a bachelor\u2019s degree in Biochemistry and a master's degree in forensic science and law. Prior to joining Restek, Samantha worked as a scientist and method developer in a forensic toxicology lab. In this role, she performed analysis on toxicology casework and worked on the development and validation of new and existing assays using LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51858","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=51858"}],"version-history":[{"count":12,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51858\/revisions"}],"predecessor-version":[{"id":74519,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/51858\/revisions\/74519"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=51858"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=51858"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=51858"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=51858"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=51858"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=51858"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=51858"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=51858"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=51858"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}