{"id":60176,"date":"2026-02-16T18:04:21","date_gmt":"2026-02-16T18:04:21","guid":{"rendered":"https:\/\/discover.restek.com\/?p=60176"},"modified":"2026-08-26T03:09:29","modified_gmt":"2026-08-26T03:09:29","slug":"gc-column-cross-reference-chart","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles\/gnot3472\/gc-column-cross-reference-chart","title":{"rendered":"GC Column Equivalent Chart"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Restek GC columns are built on a foundation of proven performance based on over 40 years of leadership in GC column development.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Groundbreaking <a href=\"https:\/\/www.restek.com\/c\/rmx\/\" target=\"_blank\" rel=\"noopener\">RMX GC columns<\/a>, manufactured with next-generation TriMax deactivation, are the latest innovation in GC column technology. RMX columns join our tried-and-true Rxi and Rtx fused silica columns, rugged metal MXT columns, and our specially bonded and stabilized PLOT columns.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">From start to finish, quality is built in at every step to ensure you get reliable chromatography and accurate results.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Available in a wide range of stationary phases, you\u2019ll find the right solution for even your most challenging applications at Restek.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This comprehensive GC column equivalent chart helps you identify Restek alternatives to columns from major manufacturers including Agilent (DB and HP series), SGE, Phenomenex, Macherey-Nagel, Supelco, and Quadrex. Our cross-reference tables cover fused silica, metal MXT, and PLOT column options across multiple stationary phases including dimethyl polysiloxane, diphenyl dimethyl polysiloxane, polyethylene glycol (PEG), and specialized polar phases to match your analytical needs.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image60176_3a8d79-a6 .kb-image-has-overlay:after{opacity:0.3;border-top-left-radius:5px;border-top-right-radius:5px;border-bottom-right-radius:5px;border-bottom-left-radius:5px;}.kb-image60176_3a8d79-a6 img.kb-img, .kb-image60176_3a8d79-a6 .kb-img img{border-top-left-radius:5px;border-top-right-radius:5px;border-bottom-right-radius:5px;border-bottom-left-radius:5px;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image60176_3a8d79-a6 size-full\"><a href=\"https:\/\/discover.restek.com\/rmx\/\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"232\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/ad-rmx-GNOT3472.jpg\" alt=\"Ad for RMX columns\" class=\"kb-img wp-image-87205\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/ad-rmx-GNOT3472.jpg 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/ad-rmx-GNOT3472-300x52.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/ad-rmx-GNOT3472-1024x177.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/ad-rmx-GNOT3472-768x133.jpg 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n\n\n<style>.kb-table-of-content-nav.kb-table-of-content-id60176_9dee71-58 .kb-table-of-content-wrap{padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-right:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);padding-left:var(--global-kb-spacing-sm, 1.5rem);}.kb-table-of-content-nav.kb-table-of-content-id60176_9dee71-58 .kb-table-of-contents-title-wrap{padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.kb-table-of-content-nav.kb-table-of-content-id60176_9dee71-58 .kb-table-of-contents-title{font-weight:regular;font-style:normal;}.kb-table-of-content-nav.kb-table-of-content-id60176_9dee71-58 .kb-table-of-content-wrap .kb-table-of-content-list{font-weight:regular;font-style:normal;margin-top:var(--global-kb-spacing-sm, 1.5rem);margin-right:0px;margin-bottom:0px;margin-left:0px;}<\/style>\n\n\n<h2 class=\"wp-block-heading\">Fused Silica GC Columns<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th><strong>Restek<\/strong><\/th><th><strong>Phase<br>Description<\/strong><\/th><th><strong>USP<br>Nomenclature<\/strong><\/th><th><strong>Similar to Agilent<\/strong><\/th><th><strong>Similar to SGE<\/strong><\/th><th><strong>Similar to Phenomenex<\/strong><\/th><th><strong>Similar to Machery-Nagel<\/strong><\/th><th><strong>Similar to Supelco<\/strong><\/th><th><strong>Similar to Quadrex<\/strong><\/th><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1688\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1688\" rel=\"noreferrer noopener\"><strong>Rtx-1<\/strong><\/a><\/td><td>dimethyl polysiloxane<\/td><td>G1, G2, G9, G38<\/td><td>HP-1, DB-1,<br>CP-Sil 5 CB<\/td><td>BP1<\/td><td>ZB-1<\/td><td>OPTIMA 1<\/td><td>Equity 1, SPB-1<\/td><td>007-1<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1683\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-1HT<\/strong><\/a><\/td><td>dimethyl polysiloxane<\/td><td><\/td><td>DB-1ht<\/td><td><\/td><td>ZB-1HT inferno<\/td><td><\/td><td><\/td><td>007-1HT<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1676\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1676\" rel=\"noreferrer noopener\"><strong>Rxi-1ms<\/strong><\/a><\/td><td>dimethyl polysiloxane<br>(low bleed)<\/td><td>G1, G2, G9, G38<\/td><td>HP-1ms,<br>HP-1ms UI,<br>DB-1ms,<br>DB-1ms UI,<br>VF-1ms<\/td><td>BP1<\/td><td>ZB-1ms<\/td><td>OPTIMA 1 MS, OPTIMA 1 MS, Accent<\/td><td>SLB-1ms<\/td><td>007-1MS<\/td><\/tr><tr><td><strong><em><mark style=\"background-color:rgba(0, 0, 0, 0);color:#d32323\" class=\"has-inline-color\">NEW! <\/mark><\/em><\/strong><br><a href=\"https:\/\/www.restek.com\/search?Ntt=RMX-5Sil+MS&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noopener\"><strong>RMX-5Sil MS<\/strong><\/a><\/td><td>1,4-bis(dimethylsiloxy) phenylene dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>DB-5msUI, DB-5Q, DB-5ms, DB-UI 8270D<\/td><td>BPX5<\/td><td>ZB-5MSPLUS, ZB-Semivolatiles<\/td><td>OPTIMA 5 MS Accent<\/td><td>SLB-5ms<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1689\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-5<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>CP-Sil 8 CB, DB-5, HP-5<\/td><td>BP5<\/td><td>ZB-5<\/td><td>OPTIMA 5<\/td><td>Equity-5, SPB-5<\/td><td>007-5<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1691\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-5MS<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>CP-Sil 8 CB, DB-5, HP-5, HP-5ms, Ultra-2<\/td><td><\/td><td>ZB-5, ZB-5MS<\/td><td><\/td><td>Equity-5, SPB-5<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1685\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-5HT<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>DB-5ht,<br>VF-5ht<\/td><td>HT5<\/td><td>ZB-5HTinferno<\/td><td>OPTIMA 5HT<\/td><td><\/td><td>007-5HT<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1675\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-5ms<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<br>(low bleed)<\/td><td>G27, G36<\/td><td>HP-5ms UI<\/td><td>BP5MS<\/td><td>ZB-5plus<\/td><td>OPTIMA 5 MS<\/td><td>SPB-5<\/td><td>007-5MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1679?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><br><strong>Rxi-5SilMS<\/strong><\/strong><\/a><\/td><td><br>1,4-bis(dimethylsiloxy)phenylenedimethylpolysiloxane<\/td><td>G27, G36<\/td><td>DB-5msUI<\/td><td>BPX5<\/td><td>ZB-5MS plus<\/td><td>OPTIMA 5 MS Accent<\/td><td>SLB-5ms<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1678\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-XLB<\/strong><\/a><\/td><td>proprietary phase<\/td><td><\/td><td>DB-XLB,<br>VF-Xms<\/td><td><\/td><td>MR1, ZB-XLB<\/td><td>OPTIMA XLB<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1692\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-20<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<\/td><td>G32<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>SPB-20<\/td><td>007-20<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1693\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-35<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<\/td><td>G42<\/td><td>HP-35, DB-35<\/td><td><\/td><td>ZB-35<\/td><td><\/td><td>SPB-35<\/td><td>007-35<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1682\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-35Sil MS<\/strong><\/a><\/td><td>proprietary phase<\/td><td>G42<\/td><td>VF-35ms<\/td><td>BPX35, BPX608<\/td><td>MR2<\/td><td>OPTIMA 35 MS<\/td><td><\/td><td>007-35MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1695\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-50<\/strong><\/a><\/td><td>phenyl methyl<br>polysiloxane<\/td><td>G3<\/td><td>HP-50+<\/td><td><\/td><td><\/td><td><\/td><td>SPB-50<\/td><td>007-17<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1673\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-17<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<\/td><td>G3<\/td><td>DB-17<\/td><td><\/td><td>ZB-50<\/td><td>OPTIMA 17<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1686\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-17Sil MS<\/strong><\/a><\/td><td>proprietary phase<\/td><td>G3<\/td><td>DB-17ms<\/td><td>BPX50<\/td><td>ZB-50<\/td><td>OPTIMA 17 MS<\/td><td><\/td><td>007-17MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1696\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-65<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>007-65HT<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1674\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-624Sil MS<\/strong><\/a><\/td><td>proprietary phase<\/td><td>G43<\/td><td>VF-624ms<\/td><td>BPX-Volatiles<\/td><td>ZB-624plus<\/td><td><\/td><td><\/td><td>007-502, 007-608, 007-624<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1677\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-1301Sil MS<\/strong><\/a><\/td><td>silarylene-based cyano<\/td><td>G43<\/td><td>VF-1301ms<\/td><td><\/td><td>ZB-624plus<\/td><td><\/td><td><\/td><td>007-502, 007-608, 007-624<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1687\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-LAO<\/strong><\/a><\/td><td>midpolarity Crossbond phase<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1680\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-SVOCms<\/strong><\/a><\/td><td>Proprietary 5% phenyl-type phase<\/td><td>G27, G36<\/td><td>DB-5ms, DB-5ms UI, DB-UI 8270D<\/td><td><\/td><td>ZB-Semivolatiles<\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1704\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-1301<\/strong><\/a><br><a href=\"https:\/\/www.restek.com\/c\/1703\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-624<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G43<\/td><td>CP-Select 624 CB, DB-1301,<br>DB-624,<br>DB-624UI,<br>DB-Select 624UI<\/td><td>BP624<\/td><td>ZB-624<\/td><td>OPTIMA 1301, OPTIMA 624<\/td><td>SPB-624<\/td><td>007-1301, 007-502,<br>007-624<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1706\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-1701<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G46<\/td><td>DB-1701P,<br>DB-1701,<br>VF-1701 Pesticides<\/td><td>BP10<\/td><td>ZB-1701,<br>ZB-1701P<\/td><td>OPTIMA 1701<\/td><td>Equity-1701<\/td><td>007-1701<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1698\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-200<\/strong><\/a><\/td><td>trifluoropropylmethyl polysiloxane<\/td><td>G6<\/td><td>DB-210,<br>DB-200<\/td><td><\/td><td><\/td><td>OPTIMA 210<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1699\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-200MS<\/strong><\/a><\/td><td>trifluoropropylmethyl polysiloxane<br>(low bleed)<\/td><td>G6<\/td><td>VF-200ms<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1700\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-225<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G7, G19<\/td><td>DB-225ms<\/td><td>BP225<\/td><td><\/td><td>OPTIMA 225<\/td><td>SPB-225<\/td><td>007-225<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1701\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-440<\/strong><\/a><\/td><td>proprietary phase<\/td><td><\/td><td colspan=\"6\"><strong>Restek Innovation<\/strong><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1707\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-2330<\/strong><\/a><\/td><td>biscyanopropyl cyanopropylphenyl<br>polysiloxane<\/td><td>G5, G8<\/td><td>VF-23ms<\/td><td>BPX70<\/td><td><\/td><td><\/td><td>SP-2330,<br>SP-2331,<br>SP-2380<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1722\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-2560<\/strong><\/a><\/td><td>biscyanopropyl polysiloxane<\/td><td>G5<\/td><td><\/td><td><\/td><td>ZB-FAME<\/td><td><\/td><td>SP-2560<\/td><td>SLP-2560<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1690\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-5 Amine<\/strong><\/a><\/td><td>5% diphenyl 95% dimethyl polysiloxane<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>OPTIMA 5 Amine<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1681\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-PAH<\/strong><\/a><\/td><td>proprietary phase<\/td><td>G51<\/td><td colspan=\"6\"><strong>Restek Innovation<\/strong><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1721\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-Wax<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16, G47<\/td><td>CP-Wax 52 CB, DB-Wax, DB-WAX UI<\/td><td>BP20<\/td><td>ZB-Wax<\/td><td>OPTIMA WAX<\/td><td><\/td><td>BRT-CW<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/p\/12497\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>FAMEWAX<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>Omegawax<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1725\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Stabilwax<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16, G47<\/td><td>HP-INNOWax<\/td><td><\/td><td>ZB-WAXplus<\/td><td><\/td><td>SUPELCOWAX 10<\/td><td>007-CW<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1726\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Stabilwax-DA<\/strong><\/a><\/td><td>polyethylene glycol modified for acids<\/td><td>G25, G35<\/td><td>CP-FFAP CB, CP-Wax 58 FFAP CB, DB-FFAP, HP-FFAP, VF-DA<\/td><td>BP21<\/td><td>ZB-FFAP<\/td><td>OPTIMA FFAP, OPTIMA FFAP Plus, PERMABOND FFAP<\/td><td>Nukol<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1727\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Stabilwax-DB<\/strong><\/a><\/td><td>polyethylene glycol modified for bases<\/td><td><\/td><td>CAM, CP-Wax 51<\/td><td><\/td><td><\/td><td>FS-CW 20 M-AM<\/td><td>Carbowax Amine<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1728\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Stabilwax-MS<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16, G47<\/td><td>VF-WAX MS<\/td><td><\/td><td><\/td><td><\/td><td>SUPELCOWAX 10<\/td><td>007-CW<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">MXT GC Columns<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th><strong>Restek<\/strong><\/th><th><strong>Phase<br>Description<\/strong><\/th><th><strong>USP<br>Nomenclature<\/strong><\/th><th><strong>Similar to Agilent<\/strong><\/th><th><strong>Similar to SGE<\/strong><\/th><th><strong>Similar to Phenomenex<\/strong><\/th><th><strong>Similar to Machery-Nagel<\/strong><\/th><th><strong>Similar to Supelco<\/strong><\/th><th><strong>Similar to Quadrex<\/strong><\/th><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1730\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-1<\/strong><\/a><\/td><td>dimethyl polysiloxane<\/td><td>G1, G2, G9, G38<\/td><td>DB-1, DB-PS1<\/td><td>BP1<\/td><td><\/td><td><\/td><td><\/td><td>UAC-1, UAC-1MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1731\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-1HT SimDist<\/strong><\/a><\/td><td>dimethyl polysiloxane<\/td><td>G1, G2, G9, G38<\/td><td>CP-SimDist<\/td><td><\/td><td>ZB-1XT SimDist<\/td><td><\/td><td><\/td><td>UAC-SIM<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1732\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-5<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>DB-PS5, VF-5ht UltiMetal<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-5, UAC-5MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1734\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-50<\/strong><\/a><\/td><td>phenyl methyl<br>polysiloxane<\/td><td>G3<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-17<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1735\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-65TG<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td><\/td><td>CP-TAP-CB Ultimetal<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-65HT<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1739\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-1301<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G43<\/td><td>DB-PS1301,<br>DB-PS624<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-624<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1740\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-1701<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G46<\/td><td>DB-PS1701<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-1701<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1736\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-200<\/strong><\/a><\/td><td>trifluoropropylmethyl polysiloxane<\/td><td>G6<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1748\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-WAX<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16<\/td><td>CP-Wax 52 CB, DB-PSWAX<\/td><td><\/td><td>ZB-WAXplus<\/td><td><\/td><td><\/td><td>UAC-CW<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">PLOT GC Columns<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th><strong>Restek<br>(Phase Description)<\/strong><\/th><th><strong>USP<br>Nomenclature<\/strong><\/th><th><strong>Porous<br>Layer<\/strong><\/th><th><strong>Application<\/strong><\/th><th><strong>Similar to Agilent<br>(J&amp;W, Varian, Chrompack)<\/strong><\/th><th><strong>Similar to Supelco<\/strong><\/th><th><strong>Similar to Quadrex<\/strong><\/th><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1751\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>C1-C5 hydrocarbons purity analysis of ethylene, propylene, butenes, and halocarbons<\/td><td>CP-Al<sub>2<\/sub>0<sub>3<\/sub>\/Na<sub>2<\/sub>SO<sub>4<\/sub>,GS-Alumina<\/td><td>Alumina-sulfate<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1743\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>C1-C5 hydrocarbons purity analysis of ethylene, propylene, butenes, and halocarbons<\/td><td>CP-Al<sub>2<\/sub>0<sub>3<\/sub>\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1749\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND\/KCl<\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>C1-C8 hydrocarbons; C1-C5 isomers purity analysis of ethylene, propylene, butene, and butadiene<\/td><td>GS-Alumina KCl,<br>HP PLOT Al<sub>2<\/sub>0<sub>3<\/sub>,<br>CP-Al<sub>2<\/sub>0<sub>3<\/sub>\/KCl<\/td><td>Alumina-chloride<\/td><td>&nbsp;<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/p\/19763\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND\/CFC<\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>Multi-halogenated alkanes, C1-C5 range chlorofluorocarbons (CFC)<\/td><td colspan=\"3\"><strong>Unique Product<\/strong><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1750\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND\/MAPD<\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>Trace analysis of methyl acetylene, propadiene, and acetylene<\/td><td>Select Al<sub>2<\/sub>0<sub>3<\/sub>&nbsp;MAPD<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1742\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-Alumina BOND\/MAPD<\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>Trace analysis of methyl acetylene, propadiene, and acetylene<\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1752\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Msieve 5A<\/strong><\/a><\/td><td><\/td><td>Molecular sieve 5A<\/td><td>Permanent gas analysis (He, Ne, Ar, O<sub>2<\/sub>, N<sub>2<\/sub>, Xe, Rn, CH<sub>4<\/sub>, and CO)<\/td><td>CP-Molsieve 5A, HP-PLOT Molesieve<\/td><td>Molsieve 5A<\/td><td>PLT-5A<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1745\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-Msieve 5A<\/strong><\/a><\/td><td><\/td><td>Molecular sieve 5A<\/td><td>Permanent gas analysis (He, Ne, Ar, O<sub>2<\/sub>, N<sub>2<\/sub>, Xe, Rn, CH<sub>4<\/sub>, and CO)<\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1753\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Q-BOND<\/strong><\/a><br>(nonpolar porous polymer)<\/td><td><\/td><td>100% Divinylbenzene<\/td><td>High retention for solvents, alcohols, polar volatiles, CO<sub>2<\/sub>, and ppm-level water in solvents<\/td><td>HP-PLOT Q, PoraBOND Q, PoraPLOT Q<\/td><td>Supel-Q-PLOT<\/td><td>PLT-Q<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1746\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-Q-BOND<\/strong><\/a> (nonpolar porous polymer)<\/td><td>G45<\/td><td>100% Divinylbenzene<\/td><td>High retention for solvents, alcohols, polar volatiles, CO<sub>2<\/sub>, and ppm-level water in solvents<\/td><td>PoraPLOT Q,<br>Ultimetal<\/td><td><\/td><td>PLT-Q&nbsp;<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1754\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-QS-BOND<\/strong><\/a><br>[intermediate polarity porous polymer (polarity between Q-BOND and S-BOND)]<\/td><td><\/td><td>Intermediate polarity porous polymer<\/td><td>Neutral solvents, ketones, esters, and hydrocarbons; baseline separation of ethane, ethene, and acetylene<\/td><td>GS-Q<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1755\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-S-BOND<\/strong><\/a><br>(intermediate polarity porous polymer)<\/td><td><\/td><td>DVB vinylpyridine polymer<\/td><td>Light gases in ethylene and propylene; ketones, esters, hydrocarbons<\/td><td>PoraPLOT S<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1756\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-U-BOND<\/strong><\/a><br>(polar porous polymer)<\/td><td>G45<\/td><td>DVB ethylene glycol-dimethylacrylate polymer<\/td><td>More retention for polar compounds; trace H<sub>2<\/sub>S, COS, and mercaptans in hydrocarbon streams<\/td><td>HP PLOT U,<br>PoraBOND U,<br>PoraPLOT U<\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If you\u2019re running other applications, use our <a href=\"https:\/\/ez.restek.com\/proezgc\" target=\"_blank\" rel=\"noopener\">Pro <em>EZ<\/em>GC Chromatogram Modeler<\/a> to find the best Restek GC column for your analyte list.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Columns by phase cross-reference chart for GC columns.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[564],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-60176","post","type-post","status-publish","format-standard","hentry","category-articles","resource-type-cross-reference"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"resource-type":[{"value":564,"label":"Cross Reference"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/60176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=60176"}],"version-history":[{"count":19,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/60176\/revisions"}],"predecessor-version":[{"id":101843,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/60176\/revisions\/101843"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=60176"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=60176"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=60176"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=60176"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=60176"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=60176"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=60176"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=60176"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=60176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}