{"id":66555,"date":"2015-06-15T16:11:16","date_gmt":"2015-06-15T16:11:16","guid":{"rendered":"https:\/\/discover.restek.com\/?p=66555"},"modified":"2026-01-08T14:24:16","modified_gmt":"2026-01-08T14:24:16","slug":"maximum-temperatures-of-packed-columns-part-1-porous-polymers","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/blogs-ja\/maximum-temperatures-of-packed-columns-part-1-porous-polymers\/","title":{"rendered":"Maximum Temperatures of Packed Columns Part 1 \u2013 Porous Polymers"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">We often get asked about the maximum temperature limit of our packed columns, so I decided to write a post series that will provide this information for the majority of the packed columns which we sell.&nbsp; I thought I would start with the least complicated packed columns, those whose packings are typically not coated with a liquid phase.&nbsp; These packings include porous polymers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For this post, I will only be focusing on HayeSep, Porapak, and Tenax packings.&nbsp; I decided not to include Chromosorb porous polymers because they are either in short supply or currently unavailable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>I am going to make the following assumption:<\/strong>&nbsp; The column\u2019s maximum temperature is limited to the packing, and&nbsp;not&nbsp;the column&#8217;s tubing; end plugs; fittings\/adaptors; and\/or ferrules used for installation. If you have a packed column that includes nonmetal tubing or end plugs other than glass wool or metal, contact Restek.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Please note<\/strong>:&nbsp; The catalog (part) numbers shown below are just for the packing and not any packed column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Keep watching for future posts on maximum temperatures of packed columns.&nbsp; Thank you.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">HayeSep Packing Materials<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Description<\/strong><\/td><td><strong>temp. limits<\/strong><\/td><td><strong>g\/btl.<\/strong><\/td><td><strong>Mesh 60\/80<\/strong><br><strong>cat.#<\/strong><\/td><td><strong>Mesh 80\/100<\/strong><br><strong>cat.#<\/strong><\/td><td><strong>Mesh 100\/120<\/strong><br><strong>cat.#<\/strong><\/td><\/tr><tr><td>HayeSep A<\/td><td>165 \u00b0C<\/td><td>24 g<\/td><td>N\/A<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25032\" target=\"_blank\" rel=\"noopener\">25032<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/25033\" target=\"_blank\" rel=\"noopener\">25033<\/a><\/td><\/tr><tr><td>HayeSep B<\/td><td>190 \u00b0C<\/td><td>24 g<\/td><td>N\/A<\/td><td>N\/A<\/td><td>N\/A<\/td><\/tr><tr><td>HayeSep C<\/td><td>250 \u00b0C<\/td><td>24 g<\/td><td colspan=\"3\">Not Available\u2013Contact your local Restek Representative for suggested replacement.<\/td><\/tr><tr><td>HayeSep D<\/td><td>290 \u00b0C<\/td><td>24 g<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25563\" target=\"_blank\" rel=\"noopener\">25563<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/25038\" target=\"_blank\" rel=\"noopener\">25038<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/25039\" target=\"_blank\" rel=\"noopener\">25039<\/a><\/td><\/tr><tr><td>HayeSep DIP<\/td><td>290 \u00b0C<\/td><td>24 g<\/td><td>N\/A<\/td><td>N\/A<\/td><td>N\/A<\/td><\/tr><tr><td>HayeSep DB<\/td><td>290 \u00b0C<\/td><td>24 g<\/td><td>N\/A<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25568\" target=\"_blank\" rel=\"noopener\">25568<\/a><\/td><td>N\/A<\/td><\/tr><tr><td>HayeSep DOX<\/td><td colspan=\"5\">(Use HayeSep DB)<\/td><\/tr><tr><td>HayeSep N<\/td><td>165 \u00b0C<\/td><td>24 g<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25570\" target=\"_blank\" rel=\"noopener\">25570<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/25045\" target=\"_blank\" rel=\"noopener\">25045<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/25046\" target=\"_blank\" rel=\"noopener\">25046<\/a><\/td><\/tr><tr><td>HayeSep P<\/td><td>250 \u00b0C<\/td><td>24 g<\/td><td colspan=\"3\">Not Available\u2013Restek recommends Porapak P as a replacement.<\/td><\/tr><tr><td>HayeSep Q<\/td><td>275 \u00b0C<\/td><td>24 g<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25572\" target=\"_blank\" rel=\"noopener\">25572<\/a><\/td><td>N\/A<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25050\" target=\"_blank\" rel=\"noopener\">25050<\/a><\/td><\/tr><tr><td>HayeSep R<\/td><td>250 \u00b0C<\/td><td>24 g<\/td><td colspan=\"3\">Not Available\u2013Restek recommends Porapak R as a replacement.<\/td><\/tr><tr><td>HayeSep S<\/td><td>250 \u00b0C<\/td><td>24 g<\/td><td>N\/A<\/td><td>N\/A<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25054\" target=\"_blank\" rel=\"noopener\">25054<\/a><\/td><\/tr><tr><td>HayeSep T<\/td><td>165 \u00b0C<\/td><td>24 g<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25575\" target=\"_blank\" rel=\"noopener\">25575<\/a><\/td><td>N\/A<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25056\" target=\"_blank\" rel=\"noopener\">25056<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Porapak Packing Materials<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Description<\/strong><\/td><td><strong>temp. limits<\/strong><\/td><td><strong>g\/btl.<\/strong><\/td><td><strong>Mesh 50\/80<\/strong><br><strong>cat.#<\/strong><\/td><td><strong>Mesh 80\/100<\/strong><br><strong>cat.#<\/strong><\/td><td><strong>Mesh 100\/120<\/strong><br><strong>cat.#<\/strong><\/td><\/tr><tr><td>Porapak P<\/td><td>250 \u00b0C<\/td><td>20 g<\/td><td colspan=\"3\" rowspan=\"8\">Available as Custom\u2013Contact your local Restek Representative for ordering information.<\/td><\/tr><tr><td>Porapak PS<\/td><td>250 \u00b0C<\/td><td>20 g<\/td><\/tr><tr><td>Porapak Q<\/td><td>250 \u00b0C<\/td><td>26 g<\/td><\/tr><tr><td>Porapak QS<\/td><td>250 \u00b0C<\/td><td>26 g<\/td><\/tr><tr><td>Porapak R<\/td><td>250 \u00b0C<\/td><td>24 g<\/td><\/tr><tr><td>Porapak S<\/td><td>250 \u00b0C<\/td><td>26 g<\/td><\/tr><tr><td>Porapak N<\/td><td>190 \u00b0C<\/td><td>29 g<\/td><\/tr><tr><td>Porapak T<\/td><td>190 \u00b0C<\/td><td>31 g<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Tenax Packing Materials<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Description<\/strong><\/td><td><strong>temp. limits<\/strong><\/td><td><strong>g\/btl.<\/strong><\/td><td><strong>Mesh 60\/80<\/strong><br><strong>cat.#<\/strong><\/td><td><strong>Mesh 80\/100<\/strong><br><strong>cat.#<\/strong><\/td><\/tr><tr><td>Tenax-TA<\/td><td>350 \u00b0C<\/td><td>10 g<\/td><td><a href=\"https:\/\/www.restek.com\/p\/25550\" target=\"_blank\" rel=\"noopener\">25550<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/25551\" target=\"_blank\" rel=\"noopener\">25551<\/a><\/td><\/tr><tr><td>Tenax-GR<\/td><td>350 \u00b0C<\/td><td>10 g<\/td><td colspan=\"2\">Not Available\u2013Contact your local Restek Representative for suggested replacement.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>We often get asked about the maximum temperature limit of our packed columns, so I decided to write a post series that will provide this information for the majority of the packed columns which we sell.&nbsp; I thought I would start with the least complicated packed columns, those whose packings are typically not coated with&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2332],"ppma_author":[582],"class_list":["post-66555","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gascromatografia-gc"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2332,"label":"Gascromatografia (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"DRCadmin","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/66555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=66555"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/66555\/revisions"}],"predecessor-version":[{"id":66886,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/66555\/revisions\/66886"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=66555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=66555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=66555"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=66555"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=66555"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=66555"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=66555"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=66555"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=66555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}