{"id":72061,"date":"2022-05-30T14:30:00","date_gmt":"2022-05-30T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=72061"},"modified":"2026-10-05T13:56:41","modified_gmt":"2026-10-05T13:56:41","slug":"chinese-see-semivolatiles-clearly-with-rugged-reliable-rxi-svocms-columns","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles-zh\/evss3820-cn\/chinese-see-semivolatiles-clearly-with-rugged-reliable-rxi-svocms-columns","title":{"rendered":"\u901a\u8fc7\u575a\u56fa\u3001\u53ef\u9760\u7684\u00a0Rxi-SVOCms \u8272\u8c31\u67f1"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u60f0\u6027\u4fdd\u6301\u6821\u51c6\u901a\u8fc7\u548c\u6837\u54c1\u8fd0\u884c\u3002<\/li>\n\n\n\n<li>\u4e34\u754c\u7269\u8d28\u5bf9\u5206\u79bb\u6548\u679c\u51fa\u8272\uff0c\u4ece\u800c\u63d0\u9ad8\u5206\u6790\u51c6\u786e\u5ea6\u3002<\/li>\n\n\n\n<li>\u67f1\u95f4\u6027\u80fd\u4e00\u81f4\u3002<\/li>\n\n\n\n<li>\u8272\u8c31\u67f1\u5bff\u547d\u957f \u3002<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color has-text-color has-link-color wp-elements-85b628d67831a09ad952ea8eb699d781 is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#e67e23;border-width:1px;color:#e67e23;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px;flex-basis:75%\">\n<p class=\"wp-block-paragraph\"><strong><em><strong><em>Our Rxi-SVOCms column was named Best New Separations Product of the Year in the SelectScience Scientists\u2019 Choice Awards<\/em><\/strong><\/em><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Restek \u65b0\u578b Rxi-SVOCms \u8272\u8c31\u67f1\uff0c\u4e13\u4e3a\u534a\u6325\u53d1\u7269\u5206\u6790\u800c\u8bbe\u8ba1\uff0c\u53ef\u786e\u4fdd\u6027\u80fd\u4e00\u81f4\uff0c\u4fdd\u6301\u6821\u51c6\u901a\u8fc7\u7684\u65f6\u95f4\u66f4\u957f\uff0c\u56e0\u6b64\u5728\u9700\u8981\u91cd\u65b0\u6821\u51c6\u4eea\u5668\u6216\u66f4\u6362\u8272\u8c31\u67f1\u4e4b\u524d\u53ef\u4ee5\u8fd0\u884c\u66f4\u591a\u6837\u54c1\u3002\u8272\u8c31\u67f1\u91c7\u7528\u65b0\u578b\u805a\u5408\u7269\u548c\u53bb\u6d3b\u5316\u5b66\u54c1\uff0c\u60f0\u6027\u9ad8\uff0c\u5177\u6709\u4e25\u683c\u63a7\u5236\u7684\u9009\u62e9\u6027\uff0c\u5bf9\u5404\u79cd\u5206\u6790\u7269\uff08\u9178\u6027\u3001\u78b1\u6027\u548c\u4e2d\u6027\uff09\u7684\u5206\u6790\u6027\u80fd\u5353\u8d8a\u3002<br>Rxi-SVOCms \u8272\u8c31\u67f1\u7ecf\u8fc7\u4e13\u95e8\u8c03\u6574\uff0c\u53ef\u6539\u5584\u6311\u6218\u6027 SVOC\uff08\u5982\u4e94\u6c2f\u82ef\u915a\u3001\u5421\u5576\u548c\u8054\u82ef\u80fa\uff09\u7684\u5cf0\u5f62\uff0c\u5e76\u53ef\u786e\u4fdd\u96be\u5206\u6790\u7684\u591a\u73af\u82b3\u70c3 (PAH) \u7684\u5206\u79bb\u5ea6\u66f4\u4f18\u3002\u5982\u56fe 1 \u6240\u793a\uff0c\u5373\u4f7f\u662f\u6700\u9ebb\u70e6\u7684\u53cd\u5e94\u6027\u5206\u6790\u7269\uff0c\u4e5f\u80fd\u83b7\u5f97\u9ad8\u5ea6\u5bf9\u79f0\u7684\u5cf0\u5f62\u548c\u826f\u597d\u7684\u54cd\u5e94\u3002\u6b64\u5916\uff0c\u5bf9\u4e8e\u82ef\u5e76[b]\u8367\u84bd\u548c\u82ef\u5e76[k]\u8367\u84bd\u8fd9\u4e9b\u5fc5\u987b\u8fdb\u884c\u8272\u8c31\u5206\u79bb\u7684\u540c\u91cd\u591a\u73af\u82b3\u70c3\u4ee5\u53ca\u831a\u5e76[1,2,3-cd]\u8298\u548c\u4e8c\u82ef\u5e76[a,h]\u84bd\u4e5f\u53ef\u83b7\u5f97\u51fa\u8272\u7684\u5206\u79bb\u5ea6\uff08\u226585% \u5cf0\u8c37\uff09\u3002<br>\u5bf9\u4e8e\u56e0\u8272\u8c31\u67f1\u6027\u80fd\u53d8\u5316\u3001\u9891\u7e41\u6821\u51c6\u5931\u8d25\u548c\u8272\u8c31\u67f1\u5bff\u547d\u77ed\u800c\u62d6\u6162\u5de5\u4f5c\u8282\u594f\u7684\u73af\u4fdd\u884c\u4e1a\u5316\u5b66\u5bb6\uff0c\u6539\u7528\u575a\u56fa\u8010\u7528\u7684 Rxi-SVOCms \u8272\u8c31\u67f1\u53ef\u786e\u4fdd\u5728\u66f4\u957f\u65f6\u95f4\u5185\u6ee1\u8db3\u6570\u636e\u8981\u6c42\uff0c\u5e76\u6700\u5927\u9650\u5ea6\u51cf\u5c11\u505c\u5de5\u65f6\u95f4\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 1<\/strong>\uff1aRxi-SVOCms \u8272\u8c31\u67f1\u7684\u8272\u8c31\u6027\u80fd\u51fa\u8272\uff0c\u5373\u4f7f\u5206\u6790\u6613\u51fa\u73b0\u95ee\u9898\u7684\u5316\u5408\u7269\u4e5f\u80fd\u53ef\u9760\u5730\u83b7\u5f97\u826f\u597d\u7684\u5cf0\u5f62\u548c\u8f83\u597d\u7684\u5206\u79bb\u5ea6\u3002\u5982\u53ef\u80fd\uff0c\u5efa\u8bae\u91c7\u7528\u5206\u6d41\u8fdb\u6837\uff0c\u56e0\u4e3a\u8fd9\u53ef\u4ee5\u6700\u5927\u9650\u5ea6\u5730\u51cf\u5c11\u8fdb\u6837\u53e3\u6c61\u67d3\u5bf9\u6837\u54c1\u8f6c\u79fb\u81f3\u5206\u6790\u67f1\u7684\u5f71\u54cd\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1604.png\" alt=\"Semivolatiles Analysis on Rxi-SVOCms\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1604<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12 peak-33\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) 1,4-Dioxane-d8\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17647-74-4\/(IS) 1,4-Dioxane-d8\" target=\"_blank\" rel=\"noopener\">(IS) 1,4-Dioxane-d8<\/a><\/td><td class=\"oth\">1.87<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N<\/i>-Nitrosodimethylamine&#8221; title=&#8221;View compound information for <i>N<\/i>-Nitrosodimethylamine&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/62-75-9\/<i>N-Nitrosodimethylamine&#8221;&gt;<i>N<\/i>-Nitrosodimethylamine<\/a><\/td><td class=\"oth\">2.00<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-86-1\/Pyridine\" target=\"_blank\" rel=\"noopener\">Pyridine<\/a><\/td><td class=\"oth\">2.03<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) 2-Fluorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/367-12-4\/(SS) 2-Fluorophenol\" target=\"_blank\" rel=\"noopener\">(SS) 2-Fluorophenol<\/a><\/td><td class=\"oth\">2.67<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) Phenol-d6\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13127-88-3\/(SS) Phenol-d6\" target=\"_blank\" rel=\"noopener\">(SS) Phenol-d6<\/a><\/td><td class=\"oth\">3.29<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-95-2\/Phenol\" target=\"_blank\" rel=\"noopener\">Phenol<\/a><\/td><td class=\"oth\">3.30<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-53-3\/Aniline\" target=\"_blank\" rel=\"noopener\">Aniline<\/a><\/td><td class=\"oth\">3.36<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-chloroethyl) ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-44-4\/Bis(2-chloroethyl) ether\" target=\"_blank\" rel=\"noopener\">Bis(2-chloroethyl) ether<\/a><\/td><td class=\"oth\">3.40<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-57-8\/2-Chlorophenol\" target=\"_blank\" rel=\"noopener\">2-Chlorophenol<\/a><\/td><td class=\"oth\">3.46<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/541-73-1\/1,3-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dichlorobenzene<\/a><\/td><td class=\"oth\">3.59<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) 1,4-Dichlorobenzene-D4\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3855-82-1\/(IS) 1,4-Dichlorobenzene-D4\" target=\"_blank\" rel=\"noopener\">(IS) 1,4-Dichlorobenzene-D4<\/a><\/td><td class=\"oth\">3.63<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-46-7\/1,4-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dichlorobenzene<\/a><\/td><td class=\"oth\">3.65<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-51-6\/Benzyl alcohol\" target=\"_blank\" rel=\"noopener\">Benzyl alcohol<\/a><\/td><td class=\"oth\">3.72<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-50-1\/1,2-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dichlorobenzene<\/a><\/td><td class=\"oth\">3.78<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-48-7\/2-Methylphenol\" target=\"_blank\" rel=\"noopener\">2-Methylphenol<\/a><\/td><td class=\"oth\">3.80<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-Chloroisopropyl)ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-60-1\/Bis(2-Chloroisopropyl)ether\" target=\"_blank\" rel=\"noopener\">Bis(2-Chloroisopropyl)ether<\/a><\/td><td class=\"oth\">3.84<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-44-5\/4-Methylphenol\" target=\"_blank\" rel=\"noopener\">4-Methylphenol<\/a><\/td><td class=\"oth\">3.93<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-39-4\/3-Methylphenol\" target=\"_blank\" rel=\"noopener\">3-Methylphenol<\/a><\/td><td class=\"oth\">3.93<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N<\/i>-Nitrosodi-<i>N<\/i>-propylamine&#8221; title=&#8221;View compound information for <i>N<\/i>-Nitrosodi-<i>N<\/i>-propylamine&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/621-64-7\/<i>N-Nitrosodi-<i>N-propylamine&#8221;&gt;<i>N<\/i>-Nitrosodi-<i>N<\/i>-propylamine<\/a><\/td><td class=\"oth\">3.95<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachloroethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-72-1\/Hexachloroethane\" target=\"_blank\" rel=\"noopener\">Hexachloroethane<\/a><\/td><td class=\"oth\">4.07<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) Nitrobenzene-D5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4165-60-0\/(SS) Nitrobenzene-D5\" target=\"_blank\" rel=\"noopener\">(SS) Nitrobenzene-D5<\/a><\/td><td class=\"oth\">4.10<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-95-3\/Nitrobenzene\" target=\"_blank\" rel=\"noopener\">Nitrobenzene<\/a><\/td><td class=\"oth\">4.11<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isophorone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-59-1\/Isophorone\" target=\"_blank\" rel=\"noopener\">Isophorone<\/a><\/td><td class=\"oth\">4.32<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-75-5\/2-Nitrophenol\" target=\"_blank\" rel=\"noopener\">2-Nitrophenol<\/a><\/td><td class=\"oth\">4.40<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dimethylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/105-67-9\/2,4-Dimethylphenol\" target=\"_blank\" rel=\"noopener\">2,4-Dimethylphenol<\/a><\/td><td class=\"oth\">4.42<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzoic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/65-85-0\/Benzoic acid\" target=\"_blank\" rel=\"noopener\">Benzoic acid<\/a><\/td><td class=\"oth\">4.46<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-chloroethoxy)methane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-91-1\/Bis(2-chloroethoxy)methane\" target=\"_blank\" rel=\"noopener\">Bis(2-chloroethoxy)methane<\/a><\/td><td class=\"oth\">4.51<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-83-2\/2,4-Dichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dichlorophenol<\/a><\/td><td class=\"oth\">4.61<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2,4-Trichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-82-1\/1,2,4-Trichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2,4-Trichlorobenzene<\/a><\/td><td class=\"oth\">4.70<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Naphthalene-D8\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1146-65-2\/(IS) Naphthalene-D8\" target=\"_blank\" rel=\"noopener\">(IS) Naphthalene-D8<\/a><\/td><td class=\"oth\">4.76<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-20-3\/Naphthalene\" target=\"_blank\" rel=\"noopener\">Naphthalene<\/a><\/td><td class=\"oth\">4.78<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-47-8\/4-Chloroaniline\" target=\"_blank\" rel=\"noopener\">4-Chloroaniline<\/a><\/td><td class=\"oth\">4.82<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobutadiene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-68-3\/Hexachlorobutadiene\" target=\"_blank\" rel=\"noopener\">Hexachlorobutadiene<\/a><\/td><td class=\"oth\">4.89<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloro-3-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-50-7\/4-Chloro-3-methylphenol\" target=\"_blank\" rel=\"noopener\">4-Chloro-3-methylphenol<\/a><\/td><td class=\"oth\">5.26<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-57-6\/2-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">2-Methylnaphthalene<\/a><\/td><td class=\"oth\">5.43<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><td class=\"oth\">5.53<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorocyclopentadiene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-47-4\/Hexachlorocyclopentadiene\" target=\"_blank\" rel=\"noopener\">Hexachlorocyclopentadiene<\/a><\/td><td class=\"oth\">5.59<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,6-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-06-2\/2,4,6-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,6-Trichlorophenol<\/a><\/td><td class=\"oth\">5.70<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,5-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-95-4\/2,4,5-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,5-Trichlorophenol<\/a><\/td><td class=\"oth\">5.73<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) 2-Fluorobiphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/321-60-8\/(SS) 2-Fluorobiphenyl\" target=\"_blank\" rel=\"noopener\">(SS) 2-Fluorobiphenyl<\/a><\/td><td class=\"oth\">5.79<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chloronaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-58-7\/2-Chloronaphthalene\" target=\"_blank\" rel=\"noopener\">2-Chloronaphthalene<\/a><\/td><td class=\"oth\">5.91<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-74-4\/2-Nitroaniline\" target=\"_blank\" rel=\"noopener\">2-Nitroaniline<\/a><\/td><td class=\"oth\">6.00<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-25-4\/1,4-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dinitrobenzene<\/a><\/td><td class=\"oth\">6.13<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/131-11-3\/Dimethyl phthalate\" target=\"_blank\" rel=\"noopener\">Dimethyl phthalate<\/a><\/td><td class=\"oth\">6.18<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-65-0\/1,3-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dinitrobenzene<\/a><\/td><td class=\"oth\">6.20<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,6-Dinitrotoluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/606-20-2\/2,6-Dinitrotoluene\" target=\"_blank\" rel=\"noopener\">2,6-Dinitrotoluene<\/a><\/td><td class=\"oth\">6.24<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/528-29-0\/1,2-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dinitrobenzene<\/a><\/td><td class=\"oth\">6.29<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><td class=\"oth\">6.31<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-09-2\/3-Nitroaniline\" target=\"_blank\" rel=\"noopener\">3-Nitroaniline<\/a><\/td><td class=\"oth\">6.40<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Acenaphthene-D10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15067-26-2\/(IS) Acenaphthene-D10\" target=\"_blank\" rel=\"noopener\">(IS) Acenaphthene-D10<\/a><\/td><td class=\"oth\">6.45<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/83-32-9\/Acenaphthene\" target=\"_blank\" rel=\"noopener\">Acenaphthene<\/a><\/td><td class=\"oth\">6.48<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-28-5\/2,4-Dinitrophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrophenol<\/a><\/td><td class=\"oth\">6.50<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-02-7\/4-Nitrophenol\" target=\"_blank\" rel=\"noopener\">4-Nitrophenol<\/a><\/td><td class=\"oth\">6.55<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrotoluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-14-2\/2,4-Dinitrotoluene\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrotoluene<\/a><\/td><td class=\"oth\">6.63<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenzofuran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-64-9\/Dibenzofuran\" target=\"_blank\" rel=\"noopener\">Dibenzofuran<\/a><\/td><td class=\"oth\">6.65<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935-95-5\/2,3,5,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,5,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">6.73<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,4,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-90-2\/2,3,4,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,4,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">6.77<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-66-2\/Diethyl phthalate\" target=\"_blank\" rel=\"noopener\">Diethyl phthalate<\/a><\/td><td class=\"oth\">6.88<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chlorophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7005-72-3\/4-Chlorophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Chlorophenyl phenyl ether<\/a><\/td><td class=\"oth\">6.99<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-73-7\/Fluorene\" target=\"_blank\" rel=\"noopener\">Fluorene<\/a><\/td><td class=\"oth\">6.99<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-01-6\/4-Nitroaniline\" target=\"_blank\" rel=\"noopener\">4-Nitroaniline<\/a><\/td><td class=\"oth\">7.00<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,6-Dinitro-2-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/534-52-1\/4,6-Dinitro-2-methylphenol\" target=\"_blank\" rel=\"noopener\">4,6-Dinitro-2-methylphenol<\/a><\/td><td class=\"oth\">7.03<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N<\/i>-Nitrosodiphenylamine&#8221; title=&#8221;View compound information for <i>N<\/i>-Nitrosodiphenylamine&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/86-30-6\/<i>N-Nitrosodiphenylamine&#8221;&gt;<i>N<\/i>-Nitrosodiphenylamine<\/a><\/td><td class=\"oth\">7.10<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N,N<\/i>-Diphenylhydrazine&#8221; title=&#8221;View compound information for <i>N,N<\/i>-Diphenylhydrazine&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/530-50-7\/<i>N,N-Diphenylhydrazine&#8221;&gt;<i>N,N<\/i>-Diphenylhydrazine<\/a><\/td><td class=\"oth\">7.15<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) 2,4,6-Tribromophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-79-6\/(SS) 2,4,6-Tribromophenol\" target=\"_blank\" rel=\"noopener\">(SS) 2,4,6-Tribromophenol<\/a><\/td><td class=\"oth\">7.23<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Bromophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-55-3\/4-Bromophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Bromophenyl phenyl ether<\/a><\/td><td class=\"oth\">7.47<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-74-1\/Hexachlorobenzene\" target=\"_blank\" rel=\"noopener\">Hexachlorobenzene<\/a><\/td><td class=\"oth\">7.53<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><td class=\"oth\">7.72<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Phenanthrene-D10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1517-22-2\/(IS) Phenanthrene-D10\" target=\"_blank\" rel=\"noopener\">(IS) Phenanthrene-D10<\/a><\/td><td class=\"oth\">7.92<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-01-8\/Phenanthrene\" target=\"_blank\" rel=\"noopener\">Phenanthrene<\/a><\/td><td class=\"oth\">7.94<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene<\/a><\/td><td class=\"oth\">7.99<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-74-8\/Carbazole\" target=\"_blank\" rel=\"noopener\">Carbazole<\/a><\/td><td class=\"oth\">8.15<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for di-n-Butyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-74-2\/di-n-Butyl phthalate\" target=\"_blank\" rel=\"noopener\">di-n-Butyl phthalate<\/a><\/td><td class=\"oth\">8.49<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">9.12<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-87-5\/Benzidine\" target=\"_blank\" rel=\"noopener\">Benzidine<\/a><\/td><td class=\"oth\">9.24<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) Pyrene-D10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1718-52-1\/(SS) Pyrene-D10\" target=\"_blank\" rel=\"noopener\">(SS) Pyrene-D10<\/a><\/td><td class=\"oth\">9.32<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129-00-0\/Pyrene\" target=\"_blank\" rel=\"noopener\">Pyrene<\/a><\/td><td class=\"oth\">9.34<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) p-Terphenyl-d14\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1718-51-0\/(SS) p-Terphenyl-d14\" target=\"_blank\" rel=\"noopener\">(SS) p-Terphenyl-d14<\/a><\/td><td class=\"oth\">9.49<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dimethylbenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119-93-7\/3,3&amp;apos;-Dimethylbenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dimethylbenzidine<\/a><\/td><td class=\"oth\">9.98<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butyl benzyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-68-7\/Butyl benzyl phthalate\" target=\"_blank\" rel=\"noopener\">Butyl benzyl phthalate<\/a><\/td><td class=\"oth\">10.00<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) adipate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-23-1\/Bis(2-ethylhexyl) adipate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) adipate<\/a><\/td><td class=\"oth\">10.09<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dichlorobenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-94-1\/3,3&amp;apos;-Dichlorobenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dichlorobenzidine<\/a><\/td><td class=\"oth\">10.62<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-55-3\/Benz[a]anthracene\" target=\"_blank\" rel=\"noopener\">Benz[a]anthracene<\/a><\/td><td class=\"oth\">10.66<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Chrysene-D12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1719-03-5\/(IS) Chrysene-D12\" target=\"_blank\" rel=\"noopener\">(IS) Chrysene-D12<\/a><\/td><td class=\"oth\">10.67<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/218-01-9\/Chrysene\" target=\"_blank\" rel=\"noopener\">Chrysene<\/a><\/td><td class=\"oth\">10.71<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-81-7\/Bis(2-ethylhexyl) phthalate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) phthalate<\/a><\/td><td class=\"oth\">10.71<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Di-n-octyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-84-0\/Di-n-octyl phthalate\" target=\"_blank\" rel=\"noopener\">Di-n-octyl phthalate<\/a><\/td><td class=\"oth\">11.68<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[b]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/205-99-2\/Benzo[b]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[b]fluoranthene<\/a><\/td><td class=\"oth\">12.30<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[k]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/207-08-9\/Benzo[k]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[k]fluoranthene<\/a><\/td><td class=\"oth\">12.34<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[a]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-32-8\/Benzo[a]pyrene\" target=\"_blank\" rel=\"noopener\">Benzo[a]pyrene<\/a><\/td><td class=\"oth\">12.89<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Perylene-D12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1520-96-3\/(IS) Perylene-D12\" target=\"_blank\" rel=\"noopener\">(IS) Perylene-D12<\/a><\/td><td class=\"oth\">13.00<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indeno[1,2,3-cd]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/193-39-5\/Indeno[1,2,3-cd]pyrene\" target=\"_blank\" rel=\"noopener\">Indeno[1,2,3-cd]pyrene<\/a><\/td><td class=\"oth\">15.32<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,h]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-70-3\/Dibenz[a,h]anthracene\" target=\"_blank\" rel=\"noopener\">Dibenz[a,h]anthracene<\/a><\/td><td class=\"oth\">15.40<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[ghi]perylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/191-24-2\/Benzo[ghi]perylene\" target=\"_blank\" rel=\"noopener\">Benzo[ghi]perylene<\/a><\/td><td class=\"oth\">15.95<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">All compounds are 2 ng on column.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-SVOCms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/16623\" rel=\"noopener\">cat.# 16623<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>8270 MegaMix standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31850\" rel=\"noopener\">cat.# 31850<\/a>)<\/td><\/tr><tr><td><\/td><td>8270 Benzidines mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31852\" rel=\"noopener\">cat.# 31852<\/a>)<\/td><\/tr><tr><td><\/td><td>Benzoic acid  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31879\" rel=\"noopener\">cat.# 31879<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised SV internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31886\" rel=\"noopener\">cat.# 31886<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised B\/N surrogate mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31888\" rel=\"noopener\">cat.# 31888<\/a>)<\/td><\/tr><tr><td><\/td><td>Acid surrogate mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31063\" rel=\"noopener\">cat.# 31063<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>20 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner with wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>60 &#176;C (hold 0.5 min) to 285 &#176;C at 25 &#176;C\/min to 305 &#176;C at 3 &#176;C\/min to 330 &#176;C at 20 &#176;C\/min (hold 5 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>1.55<\/td><td>35-500<\/td><td>5.9<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Inert <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Drawout Plate:<\/th><td>6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>180 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>DFTPP <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Samples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) containing glass Big Mouth inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21782\" rel=\"noopener\">cat.# 21782<\/a>) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23842\" rel=\"noopener\">cat.# 23842<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31850<\/li><li>31852<\/li><li>31879<\/li><li>31886<\/li><li>31888<\/li><li>31063<\/li><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1604.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u7a33\u5b9a\u6821\u51c6\u63d0\u9ad8\u6837\u54c1\u901a\u91cf<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6821\u51c6\u5931\u8d25\u610f\u5473\u7740\u751f\u4ea7\u7387\u635f\u5931\uff0c\u56e0\u4e3a\u5fc5\u987b\u6682\u505c\u6837\u54c1\u5206\u6790\u4ee5\u8fdb\u884c\u8017\u65f6\u7684\u7ef4\u62a4\u548c\u91cd\u65b0\u6821\u51c6\u3002Rxi-SVOCms \u8272\u8c31\u67f1\u60f0\u6027\u589e\u5f3a\uff0c\u53ef\u514b\u670d\u8fd9\u4e00\u7f3a<br>\u70b9\u3002\u5982\u8868 I \u6240\u793a\uff0c\u8003\u8651\u6240\u6709\u5316\u5408\u7269\u548c\u8272\u8c31\u67f1\uff0c\u53ef\u5f97\u516d\u4e2a\u8272\u8c31\u67f1\u521d\u59cb\u6821\u51c6\u7684\u5e73\u5747\u54cd\u5e94\u56e0\u5b50 %RSD \u4ec5\u4e3a 6%\u3002\u54cd\u5e94\u56e0\u5b50 %RSD \u6781\u4f4e\u4e14\u4e00\u81f4\uff0c<br>\u53ef\u786e\u4fdd\u6821\u51c6\u901a\u8fc7\u6301\u7eed\u65f6\u95f4\u66f4\u957f\uff0c\u5728\u9700\u8981\u91cd\u65b0\u6821\u51c6\u4e4b\u524d\u80fd\u8fd0\u884c\u66f4\u591a\u6837\u54c1\u3002\u5982\u56fe 2 \u6240\u793a\uff0c\u5373\u4f7f\u5206\u6790\u4e0d\u540c\u6d53\u5ea6\u7684\u5421\u5576\u548c\u4e94\u6c2f\u82ef\u915a\u4e5f\u53ef<br>\u89c2\u5bdf\u5230\u4e00\u81f4\u7684\u5cf0\u5f62\u548c\u4fdd\u7559\u65f6\u95f4\uff0c\u8fd9\u4e9b\u5316\u5408\u7269\u5bb9\u6613\u51fa\u73b0\u95ee\u9898\uff0c\u5728\u975e\u9ad8\u60f0\u6027\u8272\u8c31\u67f1\u4e0a\u5f80\u5f80\u4f1a\u62d6\u5c3e\u5e76\u5e38\u96be\u4ee5\u8fbe\u5230\u6821\u51c6\u6807\u51c6\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8868 I\uff1a<\/strong>\u6027\u80fd\u7a33\u5b9a\u610f\u5473\u7740\u91cd\u65b0\u6821\u51c6\u6b21\u6570\u66f4\u5c11\uff0c\u6709\u66f4\u591a\u7684\u65f6\u95f4\u53ef\u7528\u4e8e\u8fd0\u884c\u6837\u54c1\uff0c\u4ece\u800c\u63d0\u9ad8\u4e86\u5b9e\u9a8c\u5ba4\u751f\u4ea7\u7387\u3002\u7eff\u8272\u8868\u793a\u901a\u8fc7\u521d\u59cb\u6821\u51c6\uff08n = 6 \u4e2a\u8272\u8c31\u67f1\uff09\u3002<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Compound<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Calibration Range (\u00b5g\/mL)<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Average %RSD of Response Factors<\/strong><\/td>\n<\/tr>\n<tr>\n<td>N-Nitrosodimethylamine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.70%<\/td>\n<\/tr>\n<tr>\n<td>Pyridine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.10%<\/td>\n<\/tr>\n<tr>\n<td>(SS) 2-Fluorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.70%<\/td>\n<\/tr>\n<tr>\n<td>(SS) Phenol-d6<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.10%<\/td>\n<\/tr>\n<tr>\n<td>Phenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.20%<\/td>\n<\/tr>\n<tr>\n<td>Aniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.10%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-chloroethyl)ether<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.40%<\/td>\n<\/tr>\n<tr>\n<td>2-chlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.80%<\/td>\n<\/tr>\n<tr>\n<td>1,3-dichlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.60%<\/td>\n<\/tr>\n<tr>\n<td>1,4-Dichlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.10%<\/td>\n<\/tr>\n<tr>\n<td>Benzyl alcohol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.30%<\/td>\n<\/tr>\n<tr>\n<td>1,2-Dichlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.70%<\/td>\n<\/tr>\n<tr>\n<td>2-Methylphenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.30%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-chloroisopropyl)ether<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.40%<\/td>\n<\/tr>\n<tr>\n<td>4-Methylphenol\/3-methylphenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.30%<\/td>\n<\/tr>\n<tr>\n<td>N-nitroso-di-<em>n<\/em>-propylamine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.80%<\/td>\n<\/tr>\n<tr>\n<td>Hexachloroethane<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.00%<\/td>\n<\/tr>\n<tr>\n<td>(SS) Nitrobenzene-D5<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.60%<\/td>\n<\/tr>\n<tr>\n<td>Nitrobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.60%<\/td>\n<\/tr>\n<tr>\n<td>Isophorone<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.40%<\/td>\n<\/tr>\n<tr>\n<td>2-Nitrophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.00%<\/td>\n<\/tr>\n<tr>\n<td>2,4-Dimethylphenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.70%<\/td>\n<\/tr>\n<tr>\n<td>Benzoic acid<\/td>\n<td style=\"text-align: center;\">2.5 &#8211; 120<\/td>\n<td style=\"background-color: #fdc362; text-align: center;\">25.00%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-chloroethoxy)methane<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.60%<\/td>\n<\/tr>\n<tr>\n<td>2,4-Dichlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.10%<\/td>\n<\/tr>\n<tr>\n<td>1,2,4-Trichlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.80%<\/td>\n<\/tr>\n<tr>\n<td>Naphthalene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.20%<\/td>\n<\/tr>\n<tr>\n<td>4-Chloroaniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.90%<\/td>\n<\/tr>\n<tr>\n<td>Hexachlorobutadiene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.70%<\/td>\n<\/tr>\n<tr>\n<td>4-Chloro-3-methylphenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.40%<\/td>\n<\/tr>\n<tr>\n<td>2-Methylnaphthalene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.40%<\/td>\n<\/tr>\n<tr>\n<td>1-Methylnaphthalene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.60%<\/td>\n<\/tr>\n<tr>\n<td>Hexachlorocyclopentadiene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.90%<\/td>\n<\/tr>\n<tr>\n<td>2,4,6-Trichlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.90%<\/td>\n<\/tr>\n<tr>\n<td>2,4,5-Trichlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.20%<\/td>\n<\/tr>\n<tr>\n<td>(SS) 2-Fluorobiphenyl<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.10%<\/td>\n<\/tr>\n<tr>\n<td>2-Chloronaphthalene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.80%<\/td>\n<\/tr>\n<tr>\n<td>2-Nitroaniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.80%<\/td>\n<\/tr>\n<tr>\n<td>1,4-Dinitrobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">11.10%<\/td>\n<\/tr>\n<tr>\n<td>Dimethyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.40%<\/td>\n<\/tr>\n<tr>\n<td>1,3-Dinitrobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.80%<\/td>\n<\/tr>\n<tr>\n<td>2,6-Dinitrotoluene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.80%<\/td>\n<\/tr>\n<tr>\n<td>Acenaphthylene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.10%<\/td>\n<\/tr>\n<tr>\n<td>1,2-Dinitrobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">8.10%<\/td>\n<\/tr>\n<tr>\n<td>3-Nitroaniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.80%<\/td>\n<\/tr>\n<tr>\n<td>Acenaphthene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.30%<\/td>\n<\/tr>\n<tr>\n<td>2,4-Dinitrophenol<\/td>\n<td style=\"text-align: center;\">2.5 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">17.30%<\/td>\n<\/tr>\n<tr>\n<td>4-Nitrophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.90%<\/td>\n<\/tr>\n<tr>\n<td>Dibenzofuran<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.50%<\/td>\n<\/tr>\n<tr>\n<td>2,4-Dinitrotoluene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">11.60%<\/td>\n<\/tr>\n<tr>\n<td>2,3,5,6-Tetrachlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.40%<\/td>\n<\/tr>\n<tr>\n<td>2,3,4,6-Tetrachlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.30%<\/td>\n<\/tr>\n<tr>\n<td>Diethyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.50%<\/td>\n<\/tr>\n<tr>\n<td>4-Chlorophenyl phenyl ether<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.60%<\/td>\n<\/tr>\n<tr>\n<td>Fluorene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.40%<\/td>\n<\/tr>\n<tr>\n<td>4-Nitroaniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">9.10%<\/td>\n<\/tr>\n<tr>\n<td>4,6-Dinitro-2-methylphenol<\/td>\n<td style=\"text-align: center;\">2.5 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">15.10%<\/td>\n<\/tr>\n<tr>\n<td>N-nitrosodiphenylamine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.60%<\/td>\n<\/tr>\n<tr>\n<td>Diphenylhydrazine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.60%<\/td>\n<\/tr>\n<tr>\n<td>(SS) 2,4,6-Tribromophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.50%<\/td>\n<\/tr>\n<tr>\n<td>4-Bromophenyl phenyl ether<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.50%<\/td>\n<\/tr>\n<tr>\n<td>Hexachlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.30%<\/td>\n<\/tr>\n<tr>\n<td>Pentachlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.60%<\/td>\n<\/tr>\n<tr>\n<td>Phenanthrene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.70%<\/td>\n<\/tr>\n<tr>\n<td>Anthracene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.80%<\/td>\n<\/tr>\n<tr>\n<td>Carbazole<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.30%<\/td>\n<\/tr>\n<tr>\n<td>di-<em>n<\/em>-Butyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.90%<\/td>\n<\/tr>\n<tr>\n<td>Fluoranthene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.10%<\/td>\n<\/tr>\n<tr>\n<td>Benzidine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">9.30%<\/td>\n<\/tr>\n<tr>\n<td>(SS) Pyrene-D10<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.50%<\/td>\n<\/tr>\n<tr>\n<td>Pyrene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.30%<\/td>\n<\/tr>\n<tr>\n<td>(SS)\u00a0<em>p<\/em>-Terphenyl-d14<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.80%<\/td>\n<\/tr>\n<tr>\n<td>3,3&#8242;-Dimethylbenzidine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">9.50%<\/td>\n<\/tr>\n<tr>\n<td>Butyl benzyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">8.60%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-ethylhexyl)adipate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.50%<\/td>\n<\/tr>\n<tr>\n<td>3,3&#8242;-Dichlorobenzidine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">8.50%<\/td>\n<\/tr>\n<tr>\n<td>Benz[a]anthracene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.20%<\/td>\n<\/tr>\n<tr>\n<td>Chrysene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.70%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-ethylhexyl)phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.40%<\/td>\n<\/tr>\n<tr>\n<td>Di-<em>n<\/em>-octyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">13.20%<\/td>\n<\/tr>\n<tr>\n<td>Benzo[b]fluoranthene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.60%<\/td>\n<\/tr>\n<tr>\n<td>Benzo[k]fluoranthene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.90%<\/td>\n<\/tr>\n<tr>\n<td>Benzo[a]pyrene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.30%<\/td>\n<\/tr>\n<tr>\n<td>Indeno[123-cd]pyrene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.20%<\/td>\n<\/tr>\n<tr>\n<td>Dibenz[a,h]anthracene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.50%<\/td>\n<\/tr>\n<tr>\n<td>Benzo[ghi]perylene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.40%<\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td style=\"text-align: center;\"><strong>Average %RSD:<\/strong><\/td>\n<td style=\"background-color: #daecd4; text-align: center;\"><strong>6.00%<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 2\uff1a<\/strong>\u9ad8\u60f0\u6027 Rxi-SVOCms \u8272\u53ef\u7ed9\u51fa\u51fa\u8272\u7684\u5cf0\u5f62 \u548c\u4e00\u81f4\u7684\u4fdd\u7559\u65f6\u95f4\uff0c\u5373\u4f7f\u5bf9\u4e8e\u4f4e\u542b\u91cf\u7684\u6613\u5206\u6790\u5931\u8d25\u7684\u53cd\u5e94\u6027 \u5316\u5408\u7269\u4e5f\u662f\u5982\u6b64\uff0c\u4f8b\u5982\u5421\u5576\uff08\u78b1\u6027\u80fa\uff09\u548c\u4e94\u6c2f\u82ef\u915a\uff08\u9178\u6027\u82ef\u915a\uff09\u3002\u00a0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1605.png\" alt=\"Balanced Rxi-SVOCms Column Chemistry Produces Symmetrical Peaks and Stable Retention Times as Mass on Column Varies\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1605<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-86-1\/Pyridine\" target=\"_blank\" rel=\"noopener\">Pyridine<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-SVOCms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/16623\" rel=\"noopener\">cat.# 16623<\/a>)<\/td><\/tr><td><\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner with wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 0.5 min) to 280 &#176;C at 20 &#176;C\/min to 330 &#176;C at 6 &#176;C\/min (hold 4 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Extractor <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Extractor Lens:<\/th><td>6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>1.55  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>DFTPP <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Samples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) containing glass Big Mouth inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21782\" rel=\"noopener\">cat.# 21782<\/a>) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23842\" rel=\"noopener\">cat.# 23842<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1605.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Rxi-SVOCms \u8272\u8c31\u67f1\u575a\u56fa\u8010\u7528\u3001\u5bff\u547d\u957f\uff0c\u53ef\u8f7b\u677e\u6062\u590d\u6027\u80fd<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9ad8\u5ea6\u590d\u6742\u7684\u73af\u5883\u6837\u54c1\u7684\u7ec4\u5206\u79ef\u7d2f\u662f\u4e00\u9879\u5e38\u89c4\u6311\u6218\uff0c\u4f46\u8fd9\u4e0d\u4e00\u5b9a\u662f\u8272\u8c31\u67f1\u65e0\u6cd5\u903e\u8d8a\u7684\u969c\u788d\u3002\u67f1\u5316\u5b66\u6210\u5206\u7684\u6539\u8fdb\u786e\u4fdd\u4e86\u5373\u4f7f\u5728\u975e\u5e38\u82db\u523b\u7684\u6761\u4ef6\u4e0b\u4e5f\u80fd\u4fdd\u6301 Rxi-SVOCms \u8272\u8c31\u67f1\u6027\u80fd\u6301\u4e45\u3002\u5728\u56fe 3 \u4e2d\uff0c\u6211\u4eec\u7ed9\u8272\u8c31\u67f1\u91cd\u590d\u8fdb\u6837\u810f\u6837\u54c1\uff0c\u76d1\u6d4b\u6821\u51c6\u6027\u80fd\uff0c\u5e76\u5728\u6bcf 30 \u6b21\u8fdb\u6837\u540e\u5207\u65ad\u53d7\u6c61\u67d3\u90e8\u5206\u3002\u5373\u4f7f\u5728 300 \u6b21\u8fdb\u6837\u540e\uff0c\u4e5f\u53ef\u901a\u8fc7\u5feb\u901f\u5207\u5272\u8272\u8c31\u67f1\u8f7b\u677e\u6062\u590d\u6027\u80fd\uff0c\u5176\u4e2d\u53ea\u6709\u4e0d\u5230 10% \u7684\u5316\u5408\u7269\u672a\u80fd\u901a\u8fc7\u5207\u5272\u540e\u6821\u51c6\u68c0\u67e5\u8bc1\u660e\u4e86\u8fd9\u4e00\u70b9\u3002\u901a\u8fc7\u7b80\u5355\u7684\u65e5\u5e38\u7ef4\u62a4\u5373\u80fd\u6062\u590d\u6027\u80fd\uff0c\u8fd9\u610f\u5473\u7740\u53ef\u5206\u6790\u66f4\u591a\u7684\u6837\u54c1\u3001\u51cf\u5c11\u505c\u673a\u65f6\u95f4\u548c\u8272\u8c31\u67f1\u66f4\u6362\u6b21\u6570\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 3\uff1a<\/strong>\u91cd\u590d\u66b4\u9732\u4e8e\u9ad8\u5ea6\u590d\u6742\u7684\u6837\u54c1\u540e\uff0c\u53ef\u901a\u8fc7\u5207\u5272\u5b8c\u5168\u6062\u590d\u8272\u8c31\u67f1\u6027\u80fd\u3002\u4e4b\u540e\uff0c\u575a\u56fa\u8010\u7528\u7684 Rxi-SVOCms \u8272\u8c31\u67f1\u91cd\u65b0\u7115\u53d1\u4e86\u751f\u673a\uff0c\u53ef\u7ee7\u7eed\u8fd0\u884c\u6837\u54c1\u800c\u65e0\u9700\u66f4\u6362\u8272\u8c31\u67f1\u548c\u91cd\u65b0\u6821\u51c6\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<p class=\"wp-block-paragraph\"><em>\u8010\u7528\u6027\u6d4b\u8bd5\u5b9e\u9a8c\u8bbe\u8ba1\uff08300 \u4e2a\u6837\u54c1\uff09&nbsp;<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><em>\u6bcf\u5929\u8fdb\u6837 30 \u6b21\u67f4\u6cb9\u5fae\u7c92\u63d0\u53d6\u7269 (NIST SRM 1975)\uff0c\u6bcf 10 \u6b21\u8fdb\u6837\u540e\u8fd0\u884c\u4e00\u6b21\u6301\u7eed\u6821\u51c6\u9a8c\u8bc1 (CCV)\u3002\u6bcf\u65e5\u7b2c\u4e09\u6b21 CCV \u540e\uff0c\u5207\u5272\u8272\u8c31\u67f1\uff0c\u66f4\u6362\u886c\u7ba1\u3001\u9694\u57ab\u548c\u8fdb\u6837\u53e3\u5206\u6d41\u5e73\u677f\u3002\u8fd9\u4e00\u6b65\u9aa4\u5e8f\u5217\u91cd\u590d 10 \u5929\uff0c\u4e14\u5728\u7b2c\u4e8c\u4e2a\u8272\u8c31\u67f1\u4e0a\u91cd\u590d\u6574\u4e2a\u5b9e\u9a8c\u3002<\/em><\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u84dd\u7ebf \u6db5\u76d6\u6240\u6709 CCV \u8fdb\u6837\uff0c\u5e76\u5c55\u793a\u4e86\u7531\u4e8e\u6837\u54c1\u57fa\u8d28\u6c61\u67d3\u5bfc\u81f4\u6027\u80fd\u5148\u53d7\u635f\uff08\u5982\u9884\u671f\u7684\u90a3\u6837\uff09\uff0c\u540e\u7ecf\u7ef4\u62a4\u5b8c\u5168\u6062\u590d\u3002\u00a0<\/li>\n\n\n\n<li>\u7eff\u7ebf\u4ec5\u63cf\u7ed8\u4e86\u7ef4\u62a4\u540e CCV \u8fdb\u6837\uff0c\u5c55\u793a\u4e86\u6821\u51c6\u6027\u80fd\u7684\u7a33\u5b9a\u6027\u3002<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"742\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-1024x742.jpg\" alt=\"\" class=\"wp-image-18058\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-1024x742.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-300x217.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-768x556.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-1536x1113.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u5236\u9020\u65f6\u4fdd\u6301\u5404\u8272\u8c31\u67f1\u6027\u80fd\u4e00\u81f4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ece\u4e13\u6709\u805a\u5408\u7269\u5316\u5b66\u5230\u6700\u7ec8 QC \u6d4b\u8bd5\uff0cRxi-SVOCms \u8272\u8c31\u67f1\u7684\u6bcf\u4e2a\u5236\u9020\u6d41\u7a0b\u90fd\u7ecf\u8fc7\u4e25\u683c\u63a7\u5236\u548c\u4e25\u683c\u6d4b\u8bd5\u3002\u56e0\u6b64\uff0c\u8272\u8c31\u67f1\u7684\u67f1\u95f4\u6027\u80fd\u975e\u5e38\u4e00\u81f4\uff0c\u60a8\u53ef\u901a\u8fc7\u5b89\u88c5\u7684\u6bcf\u6839\u8272\u8c31\u67f1\u83b7\u5f97\u76f8\u540c\u7684\u8272\u8c31\u3002Rxi-SVOCms \u8272\u8c31\u67f1\u8fd8\u5177\u6709\u4fdd\u7559\u65f6\u95f4\u7a33\u5b9a\uff08\u5373\u4f7f\u662f 2,4-\u4e8c\u785d\u57fa\u82ef\u915a\u8fd9\u79cd\u7ecf\u5e38\u51fa\u73b0\u95ee\u9898\u7684\u6d3b\u6027\u5316\u5408\u7269\u4e5f\u662f\u5982\u6b64\uff09\u4ee5\u53ca\u67f1\u6d41\u5931\u6781\u4f4e\u7684\u7279\u70b9\uff08\u56fe 4\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 4\uff1a<\/strong>\u6bcf\u6839 Rxi-SVOCms \u8272\u8c31\u67f1\u4fdd\u7559\u65f6\u95f4\u4e00\u81f4\u4e14\u67f1\u6d41\u5931\u4f4e\uff0c\u56e0\u6b64\u60a8\u6536\u5230\u7684\u6bcf\u6839\u8272\u8c31\u67f1\u90fd\u80fd\u5177\u6709\u53ef\u9760\u7684\u8272\u8c31\u6027\u80fd\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1215.png\" alt=\"Rxi-SVOCms Column-to-Column Reproducibility\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1215<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Picoline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-89-4\/4-Picoline\" target=\"_blank\" rel=\"noopener\">4-Picoline<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Ethylhexanoic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/149-57-5\/2-Ethylhexanoic acid\" target=\"_blank\" rel=\"noopener\">2-Ethylhexanoic acid<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,6-Hexanediol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-11-8\/1,6-Hexanediol\" target=\"_blank\" rel=\"noopener\">1,6-Hexanediol<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-48-9\/4-Chlorophenol\" target=\"_blank\" rel=\"noopener\">4-Chlorophenol<\/a><\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Tridecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-50-5\/n-Tridecane\" target=\"_blank\" rel=\"noopener\">n-Tridecane<\/a><\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Undecanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-42-5\/1-Undecanol\" target=\"_blank\" rel=\"noopener\">1-Undecanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Tetradecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-59-4\/n-Tetradecane\" target=\"_blank\" rel=\"noopener\">n-Tetradecane<\/a><\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dicyclohexylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-83-7\/Dicyclohexylamine\" target=\"_blank\" rel=\"noopener\">Dicyclohexylamine<\/a><\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15067-26-2\/Acenaphthene-d10\" target=\"_blank\" rel=\"noopener\">Acenaphthene-d10<\/a><\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-28-5\/2,4-Dinitrophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrophenol<\/a><\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-87-5\/Benzidine\" target=\"_blank\" rel=\"noopener\">Benzidine<\/a><\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">200:1 split results in approximately 1 ng on column.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-SVOCms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/16623\" rel=\"noopener\">cat.# 16623<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Low-level activity test mix<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>200 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 200:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID Precision inlet liner with wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23305\" rel=\"noopener\">cat.# 23305<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>236 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>125 &#176;C (hold 12.5 min) to 340 &#176;C at 20 &#176;C\/min (hold 4 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>32 cm\/sec @ 125 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dead Time:<\/th><td>1.5885  min @ 125 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID @ 350 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Flow Rate:<\/th><td>40 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Type:<\/th><td>N<sub>2<\/sub> <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Hydrogen flow:<\/th><td>40 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Air flow:<\/th><td>400 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Data Rate:<\/th><td>50 Hz<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Samples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) containing glass Big Mouth inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21782\" rel=\"noopener\">cat.# 21782<\/a>) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23842\" rel=\"noopener\">cat.# 23842<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23305<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1215.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u53ef\u9760\u5206\u79bb\u5177\u6709\u6311\u6218\u6027\u7684\u73af\u5883\u00a0PAH \u5316\u5408\u7269<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u73af\u82b3\u70c3 (PAH) \u662f\u4f7f\u7528\u534a\u6325\u53d1\u7269\u65b9\u6cd5\u8fc7\u7a0b\u4e2d\u6700\u96be\u5206\u79bb\u7684\u4e00\u4e9b\u5316\u5408\u7269\u3002\u8981\u5b9e\u73b0\u51c6\u786e\u62a5\u544a\u75d5\u91cf\u7ed3\u679c\uff0c\u8272\u8c31\u67f1\u9700\u8981\u5177\u6709\u9ad8\u5ea6\u9009\u62e9\u6027\u4e14\u67f1\u6548\u9ad8\uff0c\u8fd9\u6837\u624d\u80fd\u591f\u53ef\u9760\u5206\u79bb\u7d27\u5bc6\u6d17\u8131\u7684\u5316\u5408\u7269\u3002\u5982\u56fe 5 \u6240\u793a\uff0cRxi-SVOCms \u8272\u8c31\u67f1\u4f18\u5316\u5206\u79bb\u4e86 23 \u79cd\u4f18\u5148\u6c61\u67d3\u7269\uff0c\uff08\u5305\u62ec\u82ef\u5e76[b]\u8367\u84bd\u548c\u82ef\u5e76[k]\u8367\u84bd)\uff0c\u5b83\u4eec\u987b\u8fdb\u884c\u8272\u8c31\u5206\u79bb\u624d\u80fd\u5b9e\u73b0\u5355\u72ec\u62a5\u544a\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56fe 5\uff1a<\/strong>Rxi-SVOCms \u8272\u8c31\u67f1\u53ef\u4f18\u5316\u5206\u79bb\u7d27\u5bc6\u6d17\u8131\u7684\u4f18\u5148 PAH \u6c61\u67d3\u7269\uff0c\u5305\u62ec\u4ec5\u901a\u8fc7 MS \u65e0\u6cd5\u533a\u5206\u7684\u4e34\u754c\u540c\u91cd\u7d20\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1609.png\" alt=\"Priority PAH Pollutants on Rxi-SVOCms (SIM)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1609<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-20-3\/Naphthalene\" target=\"_blank\" rel=\"noopener\">Naphthalene<\/a><\/td><td class=\"oth\">6.27<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-57-6\/2-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">2-Methylnaphthalene<\/a><\/td><td class=\"oth\">7.09<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><td class=\"oth\">7.20<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Biphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-52-4\/Biphenyl\" target=\"_blank\" rel=\"noopener\">Biphenyl<\/a><\/td><td class=\"oth\">7.65<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,6-Dimethylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/581-42-0\/2,6-Dimethylnaphthalene\" target=\"_blank\" rel=\"noopener\">2,6-Dimethylnaphthalene<\/a><\/td><td class=\"oth\">7.84<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><td class=\"oth\">8.17<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/83-32-9\/Acenaphthene\" target=\"_blank\" rel=\"noopener\">Acenaphthene<\/a><\/td><td class=\"oth\">8.38<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5-Trimethylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2245-38-7\/2,3,5-Trimethylnaphthalene\" target=\"_blank\" rel=\"noopener\">2,3,5-Trimethylnaphthalene<\/a><\/td><td class=\"oth\">8.85<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-73-7\/Fluorene\" target=\"_blank\" rel=\"noopener\">Fluorene<\/a><\/td><td class=\"oth\">9.01<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenzothiophene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-65-0\/Dibenzothiophene\" target=\"_blank\" rel=\"noopener\">Dibenzothiophene<\/a><\/td><td class=\"oth\">10.02<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-01-8\/Phenanthrene\" target=\"_blank\" rel=\"noopener\">Phenanthrene<\/a><\/td><td class=\"oth\">10.18<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene<\/a><\/td><td class=\"oth\">10.24<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylphenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/832-69-9\/1-Methylphenanthrene\" target=\"_blank\" rel=\"noopener\">1-Methylphenanthrene<\/a><\/td><td class=\"oth\">10.94<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">11.64<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129-00-0\/Pyrene\" target=\"_blank\" rel=\"noopener\">Pyrene<\/a><\/td><td class=\"oth\">11.91<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-55-3\/Benz[a]anthracene\" target=\"_blank\" rel=\"noopener\">Benz[a]anthracene<\/a><\/td><td class=\"oth\">13.45<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/218-01-9\/Chrysene\" target=\"_blank\" rel=\"noopener\">Chrysene<\/a><\/td><td class=\"oth\">13.50<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[b]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/205-99-2\/Benzo[b]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[b]fluoranthene<\/a><\/td><td class=\"oth\">15.13<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[k]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/207-08-9\/Benzo[k]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[k]fluoranthene<\/a><\/td><td class=\"oth\">15.18<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[a]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-32-8\/Benzo[a]pyrene\" target=\"_blank\" rel=\"noopener\">Benzo[a]pyrene<\/a><\/td><td class=\"oth\">15.69<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indeno[1,2,3-cd]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/193-39-5\/Indeno[1,2,3-cd]pyrene\" target=\"_blank\" rel=\"noopener\">Indeno[1,2,3-cd]pyrene<\/a><\/td><td class=\"oth\">17.77<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,h]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-70-3\/Dibenz[a,h]anthracene\" target=\"_blank\" rel=\"noopener\">Dibenz[a,h]anthracene<\/a><\/td><td class=\"oth\">17.82<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[ghi]perylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/191-24-2\/Benzo[ghi]perylene\" target=\"_blank\" rel=\"noopener\">Benzo[ghi]perylene<\/a><\/td><td class=\"oth\">18.26<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">The internal standard and surrogate standard mass on column is 20 pg.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-SVOCms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/16623\" rel=\"noopener\">cat.# 16623<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Custom PAH SIM standard<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>40 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 20:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner with wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>24 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 0.5 min) to 280 &#176;C at 20 &#176;C\/min to 330 &#176;C at 6 &#176;C\/min (hold 4 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>SIM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">SIM Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Ion(s) (m\/z)<\/th><th style=\"padding: 0 5px\">Dwell (ms)<\/th><\/tr><\/thead><tbody><tr><td style=\"vertical-align:top\">1<\/td><td style=\"vertical-align:top\">5.00<\/td><td>127.05, 128.05, 129.00 <\/td><td>25<\/td><\/tr><tr><td style=\"vertical-align:top\">2<\/td><td style=\"vertical-align:top\">6.75<\/td><td>115.10, 139.00, 141.00, 142.05 <\/td><td>25<\/td><\/tr><tr><td style=\"vertical-align:top\">3<\/td><td style=\"vertical-align:top\">7.47<\/td><td>141.00, 152.00, 153.05, 154.05, 155.05, 156.10, 162.10, 164.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">4<\/td><td style=\"vertical-align:top\">8.03<\/td><td>150.00, 151.05, 152.05, 153.05, 154.10, 162.10, 164.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">5<\/td><td style=\"vertical-align:top\">8.66<\/td><td>153.05, 155.10, 163.05, 164.10, 165.05, 166.05, 169.10, 170.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">6<\/td><td style=\"vertical-align:top\">9.62<\/td><td>139.00, 151.95, 176.10, 177.10, 178.10, 179.10, 183.95, 185.00, 188.10, 189.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">7<\/td><td style=\"vertical-align:top\">10.71<\/td><td>189.05, 190.05, 191.10, 192.10 <\/td><td>25<\/td><\/tr><tr><td style=\"vertical-align:top\">8<\/td><td style=\"vertical-align:top\">11.37<\/td><td>200.10, 201.10, 202.10, 203.05 <\/td><td>20<\/td><\/tr><tr><td style=\"vertical-align:top\">9<\/td><td style=\"vertical-align:top\">11.81<\/td><td>200.10, 201.05, 202.05, 203.05 <\/td><td>20<\/td><\/tr><tr><td style=\"vertical-align:top\">10<\/td><td style=\"vertical-align:top\">12.84<\/td><td>114.00, 120.00, 226.10, 227.10, 228.10, 229.10, 240.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">11<\/td><td style=\"vertical-align:top\">14.48<\/td><td>126.00, 132.00, 250.10, 252.10, 253.10, 264.00 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">12<\/td><td style=\"vertical-align:top\">15.51<\/td><td>126.00, 132.00, 250.05, 252.05, 253.05, 264.00 <\/td><td>20<\/td><\/tr><tr><td style=\"vertical-align:top\">13<\/td><td style=\"vertical-align:top\">16.95<\/td><td>134.50, 137.95, 139.00, 274.05, 276.10, 277.10, 278.10, 279.10 <\/td><td>20<\/td><\/tr><tr><td style=\"vertical-align:top\">14<\/td><td style=\"vertical-align:top\">18.10<\/td><td>138.00, 139.00, 274.05, 276.10, 277.10, 278.1 <\/td><td>25<\/td><\/tr><tr><td style=\"vertical-align:top\">15<\/td><td style=\"vertical-align:top\">18.80<\/td><td>150.00, 151.00, 156.00, 600.00, 302.00, 312.00 <\/td><td>25<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Extractor <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Extractor Lens:<\/th><td>6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>DFTPP <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC &amp; 5977A MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>200 ppm standard diluted 5x, then analyzed at 20:1 split. Samples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) containing glass Big Mouth inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21782\" rel=\"noopener\">cat.# 21782<\/a>) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23842\" rel=\"noopener\">cat.# 23842<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PAH<\/li><li>aromatic<\/li><li>hydrocarbons<\/li><li>polycyclic<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1609.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/16623\">                                \u8d27\u53f7\uff1a 16623                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-SVOCms GC Capillary Column, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/16623\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u8d27\u53f7\uff1a 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                \u8d27\u53f7\uff1a 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">                                \u8d27\u53f7\uff1a 21143                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap Vial with Grad Marking Spot, 9-425 Screw-Thread, 2 mL, 9 mm, 12 x 32 (vial only), Amber, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21782\">                                \u8d27\u53f7\uff1a 21782                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Glass, Big Mouth w\/ Bottom Spring, 50 \u00b5L, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21782\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23842\">                                \u8d27\u53f7\uff1a 23842                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short Screw Caps, Polypropylene, Ribbed, Screw-Thread, PTFE\/Silicone Lined, for Agilent 7693A, Blue, Preassembled, 2.0 mL, 9 mm, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23842\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Designed specifically for improved semivolatiles performance, Rxi-SVOCms columns ensure consistent chromatography that will keep calibrations passing longer so you can run more samples before needing to recalibrate the instrument or replace the column.<\/p>\n","protected":false},"author":11,"featured_media":6794,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[786],"tags":[],"industries-application":[2185,2187],"post-badge":[],"resource-type":[],"product-library":[2420,2408],"resource-technique":[2307,2312],"ppma_author":[414],"class_list":["post-72061","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-zh","industries-application-environmental-zh","industries-application-drinking-water-wastewater-testing-zh","product-library-gc-columns-zh","product-library-gas-chromatography-products-zh","resource-technique-gas-chromatography-gc-zh","resource-technique-mass-spectrometry-ms-zh"],"acf":[],"taxonomy_info":{"category":[{"value":786,"label":"\u6587\u7ae0"}],"industries-application":[{"value":2185,"label":"\u73af\u5883"},{"value":2187,"label":"\u996e\u7528\u6c34&amp;\u5e9f\u6c34\u68c0\u6d4b"}],"product-library":[{"value":2420,"label":"GC\u8272\u8c31\u67f1"},{"value":2408,"label":"\u6c14\u76f8\u8272\u8c31\u76f8\u5173\u4ea7\u54c1"}],"resource-technique":[{"value":2307,"label":"\u6c14\u76f8\u8272\u8c31\uff08GC\uff09"},{"value":2312,"label":"\u8d28\u8c31 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVSS3820-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":786,"name":"\u6587\u7ae0","slug":"articles-zh","term_group":0,"term_taxonomy_id":786,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":786,"category_count":511,"category_description":"","cat_name":"\u6587\u7ae0","category_nicename":"articles-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/72061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=72061"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/72061\/revisions"}],"predecessor-version":[{"id":105044,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/72061\/revisions\/105044"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media\/6794"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=72061"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=72061"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=72061"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=72061"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=72061"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=72061"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=72061"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=72061"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=72061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}