{"id":76419,"date":"2014-04-08T00:00:00","date_gmt":"2014-04-08T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=76419"},"modified":"2026-09-14T19:17:22","modified_gmt":"2026-09-14T19:17:22","slug":"fatty-acid-methyl-esters-fames-converting-by-weight-to-gml","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/blogs-de\/gnbl5493\/fatty-acid-methyl-esters-fames-converting-by-weight-to-gml","title":{"rendered":"Fatty Acid Methyl Esters (FAMES) &#8211; converting % by weight to \u00b5g\/mL"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The first time I was asked by a customer about how to convert % by weight of one of our FAME reference standards to \u00b5g\/mL, I needed to ask for some help.&nbsp; Because we (tech service) occasionally get asked this question, I thought I would show the calculation in a post.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Let\u2019s take Restek catalog number&nbsp;35077&nbsp;as an example.&nbsp; The overall concentration of this Food Industry FAME Mix is 30mg\/mL.&nbsp; &nbsp;Individual compound concentrations range from 2 to 6% by weight.&nbsp;&nbsp; So what are the individual compound concentrations in \u00b5g\/mL?&nbsp; &nbsp;I\u2019m not going to list them all, but rather show you how to perform this calculation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We list the first compound as C4:0 and at 4% by weight.&nbsp; Since the total concentration of 35077 is 30mg\/mL, to determine the concentration of C4:0 in \u00b5g\/mL:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4\/100 x 30mg\/mL = 0.04 x 30mg\/mL = 1.2mg\/mL<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To convert to \u00b5g\/mL:&nbsp; 1.2mg\/mL x 1000\u00b5g\/mg = 1200\u00b5g\/mL<\/p>\n\n\n<style>.kb-image76419_9ca6a3-a9 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76419_9ca6a3-a9 size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-fatty-acid-methyl-esters-fames-converting-by-weight-to-gml-01.jpg\" alt=\"\" class=\"kb-img wp-image-77740\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-fatty-acid-methyl-esters-fames-converting-by-weight-to-gml-01.jpg 200w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-fatty-acid-methyl-esters-fames-converting-by-weight-to-gml-01-150x150.jpg 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If you purchase a neat standard like&nbsp;35066, then there will be one extra step to obtaining the final answer.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This catalog number contains approximately 100mg.&nbsp; For the sake of simplicity, let\u2019s say you remove exactly 100mg and dissolve this material into 10mL of methylene chloride.&nbsp; This will produce a solution with a concentration of 10mg\/mL.&nbsp;&nbsp; Once again, I will use the first listed compound (C14:0 in this case) for an example calculation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C14:0 is in the neat material at 6% by weight.&nbsp; Since the total concentration of the solution you prepared is at 10mg\/mL:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6\/100 x 10mg\/mL = 0.06 x 10mg\/mL = 0.6mg\/mL<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To convert to \u00b5g\/mL:&nbsp; 0.6mg\/mL x 1000\u00b5g\/mg = 600\u00b5g\/mL<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;I hope you have found these examples helpful the next time you need to perform similar calculations.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks for reading.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Find our full selection of reference standards <a href=\"https:\/\/www.restek.com\/c\/1102\" target=\"_blank\" rel=\"noopener\">here.<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The first time I was asked by a customer about how to convert % by weight of one of our FAME reference standards to &micro;g\/mL, I needed to ask for some help. Because we (tech service) occasionally get asked this&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[792],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2507,2482],"resource-technique":[],"ppma_author":[582],"class_list":["post-76419","post","type-post","status-publish","format-standard","hentry","category-blogs-de","product-library-flussige-referenzstandards","product-library-referenzstandards"],"acf":[],"taxonomy_info":{"category":[{"value":792,"label":"Blogs"}],"product-library":[{"value":2507,"label":"Fl\u00fcssige Referenzstandards"},{"value":2482,"label":"Referenzstandards"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":792,"name":"Blogs","slug":"blogs-de","term_group":0,"term_taxonomy_id":792,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":792,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/76419","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=76419"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/76419\/revisions"}],"predecessor-version":[{"id":103308,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/76419\/revisions\/103308"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=76419"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=76419"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=76419"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=76419"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=76419"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=76419"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=76419"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=76419"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=76419"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}