{"id":84008,"date":"2026-01-22T17:19:48","date_gmt":"2026-01-22T17:19:48","guid":{"rendered":"https:\/\/discover.restek.com\/?p=84008"},"modified":"2026-08-11T18:29:34","modified_gmt":"2026-08-11T18:29:34","slug":"a-streamlined-cost-effective-cannabis-and-hemp-flower-workflow-for-potency-testing-2","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/posters-presentations-zh\/gnot5362\/a-streamlined-cost-effective-cannabis-and-hemp-flower-workflow-for-potency-testing-2","title":{"rendered":"A Streamlined, Cost-Effective Cannabis and Hemp Flower Workflow for Potency Testing"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">As the cannabis industry sees continued growth, production labs are looking to improve sample throughput and cut costs per sample for potency analysis. Due to ever-changing rules and regulations, it can be difficult to improve existing workflows. Keeping high-throughput labs in mind, a study was completed to obtain a streamlined workflow with minimal process time and sample touch time while keeping the cost of sample prep materials at a minimum. The study was completed by comparing different extraction volumes and vortex times as well as using a filter mate versus a centrifuge. A total of 16 cannabinoids were monitored on a UV-vis at 228 nm using a Raptor ARC-18 150 x 4.6 mm 2.7 \u03bcm analytical column with an accompanying 5 x 4.6 mm Force EXP guard cartridge under isocratic conditions with a total cycle time of 10 minutes.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-csc-west_2023_a-streamlined-cost-effective-cannabis-and-hemp-flower-workflow.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of poster-csc-west_2023_a-streamlined-cost-effective-cannabis-and-hemp-flower-workflow.\"><\/object><a id=\"wp-block-file--media-6b43050d-04ae-4686-8900-fb9ad80d0661\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-csc-west_2023_a-streamlined-cost-effective-cannabis-and-hemp-flower-workflow.pdf\">poster-csc-west_2023_a-streamlined-cost-effective-cannabis-and-hemp-flower-workflow<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-csc-west_2023_a-streamlined-cost-effective-cannabis-and-hemp-flower-workflow.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-6b43050d-04ae-4686-8900-fb9ad80d0661\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>As the cannabis industry sees continued growth, production labs are looking to improve sample throughput and cut costs per sample for potency analysis. Due to ever-changing rules and regulations, it can be difficult to improve existing workflows. Keeping high-throughput labs in mind, a study was completed to obtain a streamlined workflow with minimal process time&#8230;<\/p>\n","protected":false},"author":39,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[811],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[459,648],"class_list":["post-84008","post","type-post","status-publish","format-standard","hentry","category-posters-presentations-zh"],"acf":[],"taxonomy_info":{"category":[{"value":811,"label":"Posters &amp; Presentations"}]},"featured_image_src_large":false,"author_info":{"display_name":"Melinda Urich","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/melinda-urich\/"},"comment_info":0,"category_info":[{"term_id":811,"name":"Posters &amp; Presentations","slug":"posters-presentations-zh","term_group":0,"term_taxonomy_id":811,"taxonomy":"category","description":"","parent":0,"count":125,"filter":"raw","cat_ID":811,"category_count":125,"category_description":"","cat_name":"Posters &amp; Presentations","category_nicename":"posters-presentations-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":459,"user_id":39,"is_guest":0,"slug":"melinda-urich","display_name":"Melinda Urich","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-ulrich-melinda.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-ulrich-melinda.jpg"},"author_category":"1","first_name":"Melinda","last_name":"Urich","user_url":"https:\/\/www.linkedin.com\/in\/melinda-urich-997b81225\/","job_title":"Advanced Scientist, LC Solutions","description":"Melinda \u201cMel\u201d Urich is an applications scientist in the LC Solutions department. Her primary focus is on the development of novel applications in the cannabis and food markets. In her previous role at Restek as an LC manufacturing chemist, she led the synthesis of silica, bonding of stationary phases as well as new process implementations and improvements. Mel attended Juniata College where she earned her BS in Chemistry and performed research in Atomic Force Microscopy AFM)."},{"term_id":648,"user_id":0,"is_guest":1,"slug":"dan-delurio","display_name":"Dan DeLurio","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-delurio-daniel.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-delurio-daniel.jpg"},"author_category":"1","first_name":"Dan","last_name":"DeLurio","user_url":"https:\/\/www.linkedin.com\/in\/deluriod\/","job_title":"Sr. Business Devlopment Manager","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/84008","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/39"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=84008"}],"version-history":[{"count":1,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/84008\/revisions"}],"predecessor-version":[{"id":84010,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/84008\/revisions\/84010"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=84008"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=84008"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=84008"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=84008"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=84008"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=84008"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=84008"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=84008"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=84008"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}