{"id":92941,"date":"2026-05-11T08:36:00","date_gmt":"2026-05-11T08:36:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=92941"},"modified":"2026-10-06T18:25:45","modified_gmt":"2026-10-06T18:25:45","slug":"comparison-of-branched-pfas-by-nmr-and-chromatography","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/zh-hans\/articles-zh\/gnar5636\/comparison-of-branched-pfas-by-nmr-and-chromatography","title":{"rendered":"Comparison of % Branched PFAS by NMR and Chromatography"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Quantification of branched PFAS is a subject of interest within the larger field of PFAS testing, driven, in part, because linear and branched PFAS isomers can differ in bioactivity and distribution. Both forms are pervasive in the environment because electrochemical fluorination, a production method utilized by early manufacturers, generates a mixture of linear and branched PFAS [1]. Accurate analysis of branched PFAS is critical because the branched isomers can have notably different biological uptake rates and toxicity compared to their linear analogues [2]. Identification and quantification of the exact isomeric ratio of branched and linear PFAS is also important because it can be used forensically to identify the source of PFAS contamination [3].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Herein, three different techniques (LC-MS, LC-MS\/MS, and <sup>19<\/sup>F-NMR) were compared for the determination of the percentage of branched isomers in two sources of PFHxS. Figure 1 outlines the nomenclature for the PFHxS isomers detailed in this study.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Naming Convention of Branched PFHxS<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_23261e-e6 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_23261e-e6 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"864\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-01-1024x864.jpg\" alt=\"PFHxS compound names and structures\" class=\"kb-img wp-image-94033\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-01-1024x864.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-01-300x253.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-01-768x648.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-01.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Quantification of Branched PFAS by LC-MS\/MS and LC-MS<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For an initial test, two sources of PFHxS were analyzed by both LC-MS and LC-MS\/MS under the conditions described in Table I. For LC-MS analysis, samples were diluted to a final concentration of 45 \u00b5g\/mL in methanol. For LC-MS\/MS analysis, samples were diluted to a final concentration of 200 ng\/mL, 2 ng\/mL, and 0.2 ng\/mL. Samples were prepared and run in triplicate unless otherwise noted.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In all cases, the sum of the areas of the branched PFAS isomers was compared to the combined total area for the analyte. % Branching is expressed as 100 x (area sum of branched isomers)\/(area sum of all isomers).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> Chromatographic Conditions for Determining % Branched PFAS<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><\/td><th>LC-MS<\/th><th>LC-MS\/MS<\/th><\/tr><tr><td><strong>LC<\/strong><\/td><td>Shimadzu LC-20ADXR<\/td><td>Waters ACQUITY Premier<\/td><\/tr><tr><td><strong>Detector<\/strong><\/td><td>Shimadzu LCMS-2020<\/td><td>Waters Xevo TQ Absolute<\/td><\/tr><tr><td><strong>Column<\/strong><\/td><td>Ultra C18 (cat.# 9174312)<br>PFAS delay column (cat.# 27854)<\/td><td>Force C18 (cat.# 9634252)<br>PFAS delay column (cat.# 27854)<\/td><\/tr><tr><td><strong>Dimensions<\/strong><\/td><td>100 x 2.1 mm ID<br>Delay: 50 x 2.1 mm<\/td><td>50 x 2.1 mm ID<br>Delay: 50 x 2.1 mm<\/td><\/tr><tr><td><strong>Particle Size<\/strong><\/td><td>3 \u00b5m<br>Delay: 5 \u00b5m<\/td><td>1.8 \u00b5m<br>Delay: 5 \u00b5m<\/td><\/tr><tr><td><strong>Mobile Phase A<\/strong><\/td><td>0.5 mM ammonium acetate in water<\/td><td>0.5 mM ammonium acetate in water<\/td><\/tr><tr><td><strong>Mobile Phase B<\/strong><\/td><td>Methanol<\/td><td>Methanol<\/td><\/tr><tr><td><strong>Gradient<\/strong><\/td><td>Initial 80% A, decrease to 10% A by 10 min, hold at 10% A until 12 min<\/td><td>Initial 80% A, decrease to 5% A by 6 min, hold at 5% A until 8.5 min, change to 80% A, then hold at 80% A until 9.5 min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">As shown in Table II and Figure 2, the effect of concentration was quite pronounced; even within the same method and material, values of % branched PFAS could vary by almost as much as 40%! (10.23% to 14.93%) There was an even more noticeable jump between different analytical methods with the LC-MS method calculating a much greater amount of branched PFAS compared to the results obtained by LC-MS\/MS. Clearly, this warranted further investigation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table-TE-Test2\">\n  <p><strong>Table II:<\/strong> % Branched PFAS Determined by LC-MS\/MS and LC-MS as a Function of Measured Concentration<\/p>\n\n  <style>\n    .restek-table-wrap { overflow-x: auto; -webkit-overflow-scrolling: touch; }\n\n    .restek-table {\n      width: 100%;\n      border-collapse: collapse;\n      font-family: Arial, sans-serif;\n      font-size: 13.5px;\n      color: #333;\n      min-width: 600px;\n    }\n\n    .restek-table th,\n    .restek-table td {\n      border: 1px solid #ccc;\n      padding: 10px 12px;\n      text-align: center;\n      vertical-align: middle;\n      line-height: 1.4;\n    }\n\n    .restek-table thead tr:first-child th { font-weight: bold; background: #fff; border-bottom: none; }\n    .restek-table thead tr:nth-child(2) th { font-weight: bold; background: #fff; border-top: none; }\n    .restek-table tbody td { font-weight: normal; }\n    .restek-table tbody tr td:first-child { text-align: left; }\n\n    .restek-cards { display: none; font-family: Arial, sans-serif; color: #333; }\n\n    .restek-card { border: 1px solid #ccc; margin-bottom: 1rem; }\n\n    .restek-card-header {\n      display: flex;\n      align-items: center;\n      padding: 8px 12px;\n      border-bottom: 1px solid #ccc;\n      background: #f7f7f7;\n      font-size: 13px;\n      gap: 0;\n      flex-wrap: wrap;\n    }\n\n    .restek-card-header span {\n      padding: 0 10px;\n      border-right: 1px solid #ccc;\n      line-height: 1.4;\n    }\n\n    .restek-card-header span:first-child { padding-left: 0; }\n    .restek-card-header span:last-child { border-right: none; }\n\n    .restek-card-conc { font-weight: bold; }\n    .restek-card-meta { font-weight: bold; font-size: 13px; color: #333; }\n\n    .restek-card-sources { display: grid; grid-template-columns: 1fr 1fr; }\n\n    .restek-source-col { padding: 10px 12px; }\n    .restek-source-col:first-child { border-right: 1px solid #ccc; }\n\n    .restek-source-title {\n      font-weight: bold;\n      font-size: 12px;\n      margin-bottom: 6px;\n      text-align: center;\n      border-bottom: 1px solid #e0e0e0;\n      padding-bottom: 4px;\n    }\n\n    .restek-stat {\n      display: flex;\n      justify-content: space-between;\n      font-size: 12px;\n      padding: 3px 0;\n      border-bottom: 1px solid #f0f0f0;\n      gap: 6px;\n    }\n    .restek-stat:last-child { border-bottom: none; }\n    .restek-stat-label { color: #666; flex-shrink: 0; }\n    .restek-stat-value { text-align: right; }\n\n    @media (max-width: 600px) {\n      .restek-table-wrap { display: none; }\n      .restek-cards { display: block; }\n    }\n  <\/style>\n\n  <!-- DESKTOP TABLE -->\n  <div class=\"restek-table-wrap\">\n    <table class=\"restek-table\">\n      <thead>\n        <tr>\n          <th><\/th>\n          <th><\/th>\n          <th><\/th>\n          <th colspan=\"3\">Source 1<\/th>\n          <th colspan=\"3\">Source 2<\/th>\n        <\/tr>\n        <tr>\n          <th>Conc. (ng\/mL)<\/th>\n          <th>Log (Conc.)<\/th>\n          <th>Method<\/th>\n          <th>Linear (Area)<\/th>\n          <th>Branched (Area)<\/th>\n          <th>%Branched<\/th>\n          <th>Linear (Area)<\/th>\n          <th>Branched (Area)<\/th>\n          <th>%Branched<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>0.2<\/td><td>-0.70<\/td><td>LC-MS\/MS<\/td>\n          <td>6220.477<\/td><td>418.9723<\/td><td>6.31<\/td>\n          <td>5719.01<\/td><td>651.755<\/td><td>10.23<\/td>\n        <\/tr>\n        <tr>\n          <td>2<\/td><td>0.30<\/td><td>LC-MS\/MS<\/td>\n          <td>315781.6<\/td><td>27369.7<\/td><td>7.98<\/td>\n          <td>273846.9<\/td><td>44281.95<\/td><td>13.92<\/td>\n        <\/tr>\n        <tr>\n          <td>200<\/td><td>2.30<\/td><td>LC-MS\/MS<\/td>\n          <td>23859299<\/td><td>2330513<\/td><td>8.90<\/td>\n          <td>21574895<\/td><td>3787125<\/td><td>14.93<\/td>\n        <\/tr>\n        <tr>\n          <td>45,000<\/td><td>4.65<\/td><td>LC-MS<\/td>\n          <td>17623610<\/td><td>4177266<\/td><td>19.16<\/td>\n          <td>17825243<\/td><td>5613984<\/td><td>23.95<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <!-- MOBILE CARDS -->\n  <div class=\"restek-cards\">\n\n    <div class=\"restek-card\">\n      <div class=\"restek-card-header\">\n        <span class=\"restek-card-conc\">0.2 ng\/mL<\/span>\n        <span class=\"restek-card-meta\">Log Conc.: \u22120.70<\/span>\n        <span class=\"restek-card-meta\">LC-MS\/MS<\/span>\n      <\/div>\n      <div class=\"restek-card-sources\">\n        <div class=\"restek-source-col\">\n          <div class=\"restek-source-title\">Source 1<\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Linear<\/span><span class=\"restek-stat-value\">6220.477<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Branched<\/span><span class=\"restek-stat-value\">418.9723<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">%Branched<\/span><span class=\"restek-stat-value\">6.31<\/span><\/div>\n        <\/div>\n        <div class=\"restek-source-col\">\n          <div class=\"restek-source-title\">Source 2<\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Linear<\/span><span class=\"restek-stat-value\">5719.01<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Branched<\/span><span class=\"restek-stat-value\">651.755<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">%Branched<\/span><span class=\"restek-stat-value\">10.23<\/span><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"restek-card\">\n      <div class=\"restek-card-header\">\n        <span class=\"restek-card-conc\">2 ng\/mL<\/span>\n        <span class=\"restek-card-meta\">Log Conc.: 0.30<\/span>\n        <span class=\"restek-card-meta\">LC-MS\/MS<\/span>\n      <\/div>\n      <div class=\"restek-card-sources\">\n        <div class=\"restek-source-col\">\n          <div class=\"restek-source-title\">Source 1<\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Linear<\/span><span class=\"restek-stat-value\">315781.6<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Branched<\/span><span class=\"restek-stat-value\">27369.7<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">%Branched<\/span><span class=\"restek-stat-value\">7.98<\/span><\/div>\n        <\/div>\n        <div class=\"restek-source-col\">\n          <div class=\"restek-source-title\">Source 2<\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Linear<\/span><span class=\"restek-stat-value\">273846.9<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Branched<\/span><span class=\"restek-stat-value\">44281.95<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">%Branched<\/span><span class=\"restek-stat-value\">13.92<\/span><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"restek-card\">\n      <div class=\"restek-card-header\">\n        <span class=\"restek-card-conc\">200 ng\/mL<\/span>\n        <span class=\"restek-card-meta\">Log Conc.: 2.30<\/span>\n        <span class=\"restek-card-meta\">LC-MS\/MS<\/span>\n      <\/div>\n      <div class=\"restek-card-sources\">\n        <div class=\"restek-source-col\">\n          <div class=\"restek-source-title\">Source 1<\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Linear<\/span><span class=\"restek-stat-value\">23859299<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Branched<\/span><span class=\"restek-stat-value\">2330513<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">%Branched<\/span><span class=\"restek-stat-value\">8.90<\/span><\/div>\n        <\/div>\n        <div class=\"restek-source-col\">\n          <div class=\"restek-source-title\">Source 2<\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Linear<\/span><span class=\"restek-stat-value\">21574895<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Branched<\/span><span class=\"restek-stat-value\">3787125<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">%Branched<\/span><span class=\"restek-stat-value\">14.93<\/span><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <div class=\"restek-card\">\n      <div class=\"restek-card-header\">\n        <span class=\"restek-card-conc\">45,000 ng\/mL<\/span>\n        <span class=\"restek-card-meta\">Log Conc.: 4.65<\/span>\n        <span class=\"restek-card-meta\">LC-MS<\/span>\n      <\/div>\n      <div class=\"restek-card-sources\">\n        <div class=\"restek-source-col\">\n          <div class=\"restek-source-title\">Source 1<\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Linear<\/span><span class=\"restek-stat-value\">17623610<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Branched<\/span><span class=\"restek-stat-value\">4177266<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">%Branched<\/span><span class=\"restek-stat-value\">19.16<\/span><\/div>\n        <\/div>\n        <div class=\"restek-source-col\">\n          <div class=\"restek-source-title\">Source 2<\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Linear<\/span><span class=\"restek-stat-value\">17825243<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">Branched<\/span><span class=\"restek-stat-value\">5613984<\/span><\/div>\n          <div class=\"restek-stat\"><span class=\"restek-stat-label\">%Branched<\/span><span class=\"restek-stat-value\">23.95<\/span><\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n  <\/div>\n\n<\/figure>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> % Branching As a Function of Measured Concentration<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_b1b160-fb .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_b1b160-fb size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"492\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-02-1024x492.jpg\" alt=\"bar chart of branched PFAS\" class=\"kb-img wp-image-94039\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-02-1024x492.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-02-300x144.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-02-768x369.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-02.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">To delve further into the impact of concentration, the LC-MS\/MS method was used to analyze a sample of source 2 that was diluted across a much wider concentration range (0.009 ng\/mL to 1480 ng\/mL) than was previously tested using this technique. Results are shown in Table III and Figure 3.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III: <\/strong>Extended Linear Range Testing of PFHxS by LC-MS\/MS<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Concentration (ng\/mL)<\/th><th class=\"has-text-align-center\" data-align=\"center\">Linear (Area)<\/th><th class=\"has-text-align-center\" data-align=\"center\">Branched (Area)<\/th><th class=\"has-text-align-center\" data-align=\"center\">% Branched<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">0.009<\/td><td class=\"has-text-align-center\" data-align=\"center\">276.907<\/td><td class=\"has-text-align-center\" data-align=\"center\">48.384<\/td><td class=\"has-text-align-center\" data-align=\"center\">14.87407<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.074<\/td><td class=\"has-text-align-center\" data-align=\"center\">1795.388<\/td><td class=\"has-text-align-center\" data-align=\"center\">351.731<\/td><td class=\"has-text-align-center\" data-align=\"center\">16.38153<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.092<\/td><td class=\"has-text-align-center\" data-align=\"center\">1980.368<\/td><td class=\"has-text-align-center\" data-align=\"center\">370.349<\/td><td class=\"has-text-align-center\" data-align=\"center\">15.75473<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.185<\/td><td class=\"has-text-align-center\" data-align=\"center\">3933.348<\/td><td class=\"has-text-align-center\" data-align=\"center\">716.919<\/td><td class=\"has-text-align-center\" data-align=\"center\">15.41673<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.277<\/td><td class=\"has-text-align-center\" data-align=\"center\">6897.543<\/td><td class=\"has-text-align-center\" data-align=\"center\">1369.095<\/td><td class=\"has-text-align-center\" data-align=\"center\">16.56169<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0.74<\/td><td class=\"has-text-align-center\" data-align=\"center\">17551.12<\/td><td class=\"has-text-align-center\" data-align=\"center\">3478.774<\/td><td class=\"has-text-align-center\" data-align=\"center\">16.54204<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">2.775<\/td><td class=\"has-text-align-center\" data-align=\"center\">59034.63<\/td><td class=\"has-text-align-center\" data-align=\"center\">12011.85<\/td><td class=\"has-text-align-center\" data-align=\"center\">16.90704<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">7.4<\/td><td class=\"has-text-align-center\" data-align=\"center\">156885.8<\/td><td class=\"has-text-align-center\" data-align=\"center\">31021.65<\/td><td class=\"has-text-align-center\" data-align=\"center\">16.50901<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">148<\/td><td class=\"has-text-align-center\" data-align=\"center\">382294<\/td><td class=\"has-text-align-center\" data-align=\"center\">78220.66<\/td><td class=\"has-text-align-center\" data-align=\"center\">16.98549<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">296<\/td><td class=\"has-text-align-center\" data-align=\"center\">744305.6<\/td><td class=\"has-text-align-center\" data-align=\"center\">154995.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">17.23507<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">740<\/td><td class=\"has-text-align-center\" data-align=\"center\">1592732<\/td><td class=\"has-text-align-center\" data-align=\"center\">391488.9<\/td><td class=\"has-text-align-center\" data-align=\"center\">19.7301<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">1480<\/td><td class=\"has-text-align-center\" data-align=\"center\">2569690<\/td><td class=\"has-text-align-center\" data-align=\"center\">835119<\/td><td class=\"has-text-align-center\" data-align=\"center\">24.52763<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3: <\/strong>% Branched PFHxS As a Function of Measured Concentration<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_6f7319-48 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_6f7319-48 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"492\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-03-1024x492.jpg\" alt=\"line chart of branched PFHxS\" class=\"kb-img wp-image-94045\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-03-1024x492.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-03-300x144.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-03-768x369.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-03.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">There\u2019s a notable increase in the calculated % branched PFHxS at the high end of the concentration range. This is consistent with detector saturation of the more abundant linear isomer before the branched isomers. Presumably, as the slope of the linear isomer\u2019s response begins to plateau, the amount of branched isomers continues to increase. Ultimately this results in higher calculated % branched PFAS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">On the other extreme, there\u2019s a slight decrease in the % branched PFAS at the low end of the concentration range. This decrease is likely due to loss of signal of the less abundant branched isomers prior to the loss of signal for the linear isomer. For PFHxS, sensitivity is high enough that this decrease in signal is not outside of the linear range for this study. However, for a compound with slightly less sensitivity, such as PFOS, this low-level effect becomes much more prominent (Figure 4).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4: <\/strong>% Branched PFOS As a Function of Measured Concentration<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_794ec4-8e .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_794ec4-8e size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"492\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-04-1024x492.jpg\" alt=\"line chart of branched PFOS\" class=\"kb-img wp-image-94051\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-04-1024x492.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-04-300x144.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-04-768x369.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-04.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Clearly, there\u2019s an appropriate linear range in which % branched PFAS can be determined chromatographically. The exact linear range is dependent on multiple factors, including chromatographic resolution, instrument sensitivity, and % branching within the sample. Without discrete standards for each isomer, direct comparison across different analytical systems is almost impossible.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That poses a real concern for testing certificated reference materials. If a manufacturer determines % branched PFAS in a reference material chromatographically, the end user might determine a significantly different result based on differing conditions. To resolve some of those issues, we can explore another method of quantification: nuclear magnetic resonance (NMR).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Quantification of Branched PFAS by <sup>19<\/sup>FNMR<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">NMR measures individual moieties within a molecule rather than separating compounds based on retention to a stationary phase. It requires the presence of a nonzero spin nuclei (typical <sup>1<\/sup>H or <sup>13<\/sup>C) with an observable magnetic moment. <sup>19<\/sup>F is a highly abundant spin-active nuclei (l=1\/2), which is a valuable tool for the analysis of these highly fluorinated molecules.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><sup>19<\/sup>FNMR provides several unique benefits compared to chromatography:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Structure assignments can be determined by either unique chemical shifts or longer range (<em>J<\/em><sub>4<\/sub>) coupling constants.<\/li>\n\n\n\n<li>Quantification is relatively straight forward. Integrations are proportional to the number of fluorine atoms within a moiety rather than on the response factor of the analyte as a whole, and as such, quantification does not require isolation of each isomer.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><sup>19<\/sup>FNMR has one chief benefit compared to more typical HNMR\u2014its large chemical window. Let\u2019s look at our example molecule, PFHxS. Here, as shown in Figure 5, the spectra can be divided into three large domains depending on the number of fluorine atoms directly attached to the geminal carbon. CF<sub>3<\/sub> groups tend to appear around -60 to -100 ppm, CF<sub>2<\/sub> groups appear around -110 to -140 ppm, and CF groups appear after -170 ppm.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> Typical Compound Domains Across an FNMR Window<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_2351ca-c5 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_2351ca-c5 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"552\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-05-1024x552.jpg\" alt=\"\" class=\"kb-img wp-image-94057\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-05-1024x552.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-05-300x162.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-05-768x414.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-05.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Furthermore, we can subdivide each of these domains based on the functionality within the <em>vicinal <\/em>carbon. For example, within the CF<sub>3<\/sub> domain we can observe a different chemical shift for CF<sub>3<\/sub> groups with vicinal CF<sub>2<\/sub>, CF, or C groups (Figure 6). &nbsp;A similar shift can be observed for both CF<sub>2<\/sub> and CF moieties. In general, more fluorine atoms on the vicinal carbon results in a more upfield shift.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> Subdivisions within the CF<sub>3<\/sub> Domain Based on Vicinal Groups<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_370887-bd .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_370887-bd size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"535\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-06-1024x535.jpg\" alt=\"\" class=\"kb-img wp-image-94063\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-06-1024x535.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-06-300x157.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-06-768x401.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-06.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Next, we can utilize coupling to further help identify each isomer. Perfluoroalkyl groups are interesting in the fact that coupling between fluorine atoms appears predominately to take place through space [4]. As such, the typical J<sub>2<\/sub> coupling that would be expected in HNMR is much smaller (&lt;2 Hz) than a J<sub>4<\/sub> coupling\u2014a revelation that prior to my understanding, led to many a confusing structural assignment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A prime example of the oddities of this domination of through-space coupling is the molecule, NFDHA (nonafluoro-3,6-dioxaheptanoic acid, CAS: 151772-58-6), compared to its non-fluorinated analogue, (2-methoxyethoxy)acetic acid, CAS: 16024-56-9). Both fluorinated ends couple to remote CF<sub>2<\/sub> groups through an ether moiety, whereas the adjacent CF<sub>2<\/sub> groups do not couple to each other (Figure 7). Ultimately, coupling in NFDHA results in three triplets and one quartet. Conversely, (2-methoxyethoxy)acetic acid is predicted to exhibit a pair of singlets and a pair of triplets with only the two adjacent methylene moieties coupling together.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:<\/strong> Coupling Comparison between NFDHA (top) and (2-Methoxyethoxy)acetic Acid (bottom)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_091bd2-c1 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_091bd2-c1 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"844\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-07-1024x844.jpg\" alt=\"\" class=\"kb-img wp-image-94069\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-07-1024x844.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-07-300x247.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-07-768x633.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-07.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Back to a more relevant example for our current subject matter of isomeric assignment: let\u2019s consider the isomers 3,3-dm, and 3-m (Figure 8).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:<\/strong> Linear and Branched PFHxS Isomers<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_d8e256-ff .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_d8e256-ff size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"190\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-08-1024x190.jpg\" alt=\"chemical structures for PFHxS isomers\" class=\"kb-img wp-image-94075\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-08-1024x190.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-08-300x56.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-08-768x142.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-08.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Starting with 3,3-dm, the defining feature of the molecule is the perfluoro-tert-butyl moiety. With its distinctive tertiary carbon center, we would expect a single peak corresponding to a total of nine fluorine atoms fairly far downfield within the CF<sub>3<\/sub> domain. Indeed, in Figure 9, we can observe a pseudo pentet around -66 ppm with a rather large coupling constant of 13.6 Hz.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 9:<\/strong> Coupling Assignments for 3,3-dm<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_bff905-3a .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_bff905-3a size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-09-1024x559.jpg\" alt=\"\" class=\"kb-img wp-image-94081\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-09-1024x559.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-09-300x164.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-09-768x420.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-09.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Eagle-eyed observers might also note a slight splitting of each peak within the pseudo pentet. I would hypothesize the observed peak is an overlay of two similar signals\u2014one for the CF<sub>3<\/sub> group <em>anti<\/em> to the CF<sub>2<\/sub> group adjacent to the end group, and another for the two CF<sub>3<\/sub> groups <em>syn<\/em> to the CF<sub>2<\/sub> group adjacent to the end group. At the temperature at which the spectrum was acquired (25 \u00b0C), rotation about the C-C bond is sufficiently restricted such that we observe two distinct but very similar peaks. Variable temperature NMR was outside of the scope of this work, but it would be interesting to observe if coalescence would be reached given a sufficiently high temperature.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Next, let\u2019s look at 3-m. The CF<sub>3<\/sub> group on the 3-position is vicinal to a CF moiety. We can observe a triplet-quartet at around -85 ppm with coupling constants 7 and 13 Hz (Figure 10).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 10:<\/strong> Coupling Assignments for 3-m<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_641e8b-5e .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_641e8b-5e size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"462\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-10-1024x462.jpg\" alt=\"\" class=\"kb-img wp-image-94087\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-10-1024x462.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-10-300x135.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-10-768x346.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-10.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">It should be noted that <sup>19<\/sup>FNMR has some shortfalls for isomeric assignments. Assignment based on long-range coupling requires well-resolved peaks. For very structurally similar compounds, overlapping signals can make unambiguous assignment impossible. For example, as shown in Figure 11, we observe a complicated overlay of two multiplets around -75.5 ppm.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 11:<\/strong> Example of Overlapping Multiplets<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image92941_aa9328-13 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image92941_aa9328-13 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"439\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-11-1024x439.jpg\" alt=\"\" class=\"kb-img wp-image-94093\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-11-1024x439.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-11-300x129.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-11-768x330.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnar5636-11.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">In such a case, we can\u2019t definitely identify which isomers correspond to the observed peaks without having a reference material for comparison. Still, based on the chemical shift data, we can assign these to a CF<sub>3<\/sub> group adjacent to a CF group. We can assign the number of fluorine atoms as equal to three and integrate the sum of both as an unknown isomer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once we\u2019ve made assignments to the best of our abilities, we can quantify each isomer. To do so, the typical procedure is as follows:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Integrate <em>one<\/em> unique moiety per isomer.<\/li>\n\n\n\n<li>Set the total integration to a fixed number (e.g., 100).<\/li>\n\n\n\n<li>Divide each peak area by its number of fluorine atoms (e.g., a peak corresponding to a CF<sub>3<\/sub> group is divided by three).<\/li>\n\n\n\n<li>Determine the percentage of each isomer based on these normalized areas.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Table IV shows a typical isomeric breakdown.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table IV:<\/strong> Relative Percentage of PFHxS Isomers in Source 1<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>PFHxS<\/th><th class=\"has-text-align-center\" data-align=\"center\">Area<\/th><th class=\"has-text-align-center\" data-align=\"center\">#F<\/th><th class=\"has-text-align-center\" data-align=\"center\">Normalized Area<\/th><th class=\"has-text-align-center\" data-align=\"center\">% Total<\/th><\/tr><\/thead><tbody><tr><td>linear<\/td><td class=\"has-text-align-center\" data-align=\"center\">81.57<\/td><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><td class=\"has-text-align-center\" data-align=\"center\">27.19<\/td><td class=\"has-text-align-center\" data-align=\"center\">86.73<\/td><\/tr><tr><td>1-m<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1100<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1100<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.3508<\/td><\/tr><tr><td>2-m<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.3500<\/td><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1750<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5582<\/td><\/tr><tr><td>3-m<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.910<\/td><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.6366<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.030<\/td><\/tr><tr><td>4-m<\/td><td class=\"has-text-align-center\" data-align=\"center\">11.95<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.991<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.353<\/td><\/tr><tr><td>3,3-dm<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1800<\/td><td class=\"has-text-align-center\" data-align=\"center\">9<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.02000<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.06380<\/td><\/tr><tr><td>Unknown 1<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.600<\/td><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.8666<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.764<\/td><\/tr><tr><td>Unknown 2<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.7200<\/td><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.3600<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.148<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The isomeric breakdown for each source measured by <sup>19<\/sup>FNMR is compared in Table V.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table V:<\/strong> Comparison of PFHxS Isomers by Source<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><\/th><th class=\"has-text-align-center\" data-align=\"center\">Source 1<\/th><th class=\"has-text-align-center\" data-align=\"center\">Source 2*<\/th><\/tr><\/thead><tbody><tr><th>Isomer<\/th><th class=\"has-text-align-center\" data-align=\"center\">% Total<\/th><th class=\"has-text-align-center\" data-align=\"center\">% Total<\/th><\/tr><tr><td>linear<\/td><td class=\"has-text-align-center\" data-align=\"center\">86.7<\/td><td class=\"has-text-align-center\" data-align=\"center\">81.1<\/td><\/tr><tr><td>1-m<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.4<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.9<\/td><\/tr><tr><td>2-m<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.6<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.4<\/td><\/tr><tr><td>3-m<\/td><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td>4-m<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.4<\/td><td class=\"has-text-align-center\" data-align=\"center\">8.9<\/td><\/tr><tr><td>3,3-dm<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.2<\/td><\/tr><tr><td>Unknown<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.9<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5<\/td><\/tr><tr><td colspan=\"3\">* Information from vendor <\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Finally, we can compare our measured % branched PFHxS results across all three techniques (Table VI). In general, LC-MS\/MS underreports % branched PFAS, likely due to unresolved separation of isomers from the linear molecule. The larger discrepancy between the LC-MS\/MS and NMR data for Source 1 than for Source 2 might suggest that the unknown isomers noted in <sup>19<\/sup>FNMR are likely coeluting with the linear isomer. Data from LC-MS was generally higher for both sources, likely due to detector oversaturation of the linear isomer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table VI:<\/strong> Comparison of % Branched PFHxS by Technique<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><\/th><th class=\"has-text-align-center\" data-align=\"center\">Source 1<\/th><th class=\"has-text-align-center\" data-align=\"center\">Source 2<\/th><\/tr><\/thead><tbody><tr><td>LC-MS<\/td><td class=\"has-text-align-center\" data-align=\"center\">20.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">21.86<\/td><\/tr><tr><td>LC-MS\/MS<\/td><td class=\"has-text-align-center\" data-align=\"center\">8.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">14.93<\/td><\/tr><tr><td><sup>19<\/sup>FNMR<\/td><td class=\"has-text-align-center\" data-align=\"center\">13.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">18.90<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Care should be taken when applying % branching data derived from NMR directly to chromatographic analysis because NMR can often resolve linear and branched compounds that are likely to coelute chromatographically. Using values for % branched PFAS determined by NMR directly will likely result in overreporting of % branched PFAS. When analyzing new lots of PFAS material by LC-MS\/MS, it\u2019s recommended that % branched PFAS and an appropriate linear range be determined empirically under the exact chromatographic conditions to be used for analysis.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">References<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The science of organic fluorochemistry. 3M Co. Document.1999. <a href=\"https:\/\/www.ag.state.mn.us\/Office\/Cases\/3M\/docs\/PTX\/PTX1558.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.ag.state.mn.us\/Office\/Cases\/3M\/docs\/PTX\/PTX1558.pdf<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">K. Schulz, M. Silva, R. Klaper, Distribution and effects of branched versus linear isomers of PFOA, PFOS, and PFHxS: A review of recent literature, Sci. Total Environ., 733 (2020) <a href=\"https:\/\/doi.org\/10.1016\/j.scitotenv.2020.139186\" target=\"_blank\" rel=\"noopener\">https:\/\/doi.org\/10.1016\/j.scitotenv.2020.139186<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">M.J. Benotti, L.A Fernandez, G.F. Peaslee, G.S. Douglas, A.D. Uhler, S. Emsbo-Mattingly A forensic approach for distinguishing PFAS materials. 2020, Environ. Forensics, 21 (3-4) (2020) 319\u2013333. <a href=\"https:\/\/doi.org\/10.1080\/15275922.2020.1771631\" target=\"_blank\" rel=\"noopener\">https:\/\/doi.org\/10.1080\/15275922.2020.1771631<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W. Dolbier, Guide to fluorine NMR for organic chemists, John Wiley &amp; Sons, Hoboken, New Jersey, 2016. <a href=\"https:\/\/doi.org\/10.1002\/9781118831106\" target=\"_blank\" rel=\"noopener\">https:\/\/doi.org\/10.1002\/9781118831106<\/a><\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u76f8\u5173\u4ea7\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9174312\">                                \u8d27\u53f7\uff1a 9174312                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ultra C18, 3 \u00b5m, 100 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9174312\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">                                \u8d27\u53f7\uff1a 9634252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force C18, 1.8 \u00b5m, 50 x 2.1 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u8d27\u53f7\uff1a 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS Delay Column, 5 \u00b5m, 50 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30803\">                                \u8d27\u53f7\uff1a 30803                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Perfluorohexanesulfonic acid (br-PFHxS) Standard, 100 \u00b5g\/mL, Methanol (1 mM NaOH)\/2-propanol (98:2), 1.2 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30803\">\u67e5\u770b\u4ea7\u54c1<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col,.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_3b9a6b-09{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_3b9a6b-09 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_3b9a6b-09 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id99903_b5fa4b-ad{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id99903_b5fa4b-ad > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id99903_b5fa4b-ad > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id99903_b5fa4b-ad alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column99903_2824bd-5d > .kt-inside-inner-col,.kadence-column99903_2824bd-5d > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column99903_2824bd-5d > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column99903_2824bd-5d{position:relative;}@media all and (max-width: 1024px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column99903_2824bd-5d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column99903_2824bd-5d\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb, .wp-block-kadence-advancedheading.kt-adv-heading99903_df06fd-cb[data-kb-block=\"kb-adv-heading99903_df06fd-cb\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading99903_df06fd-cb wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading99903_df06fd-cb\"><span class=\"kb-adv-text-inner\">\u60a8\u7684PFAS\u5206\u6790\u9700\u8981\u5e2e\u52a9\u5417\uff1f<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-f665c15039f1a4afbba75872873e13a0 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">\u4ece\u65b9\u6cd5\u9009\u62e9\u5230\u4ea7\u54c1\u63a8\u8350\uff0cRestek PFAS \u4e13\u5bb6\u52a9\u60a8\u5e94\u5bf9\u590d\u6742\u5206\u6790\u6d41\u7a0b\uff0c\u83b7\u5f97\u51c6\u786e\u3001\u53ef\u9760\u7684\u5206\u6790\u7ed3\u679c\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns99903_bac608-3f{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns99903_bac608-3f .kt-button{font-weight:normal;font-style:normal;}.kt-btns99903_bac608-3f .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns99903_bac608-3f .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns99903_bac608-3f\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn99903_980c0c-c6.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn99903_980c0c-c6.kb-button:hover .kb-svg-icon-wrap, .kb-btn99903_980c0c-c6.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn99903_980c0c-c6.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn99903_980c0c-c6 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn\" href=\"https:\/\/explore.restek.com\/PFAS\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Contact a PFAS<\/strong> <strong>expert<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This study compares the use of NMR, LC-MS, and LC-MS\/MS for the quantification of linear and branched PFAS isomers using PFHxS as an example compound.<\/p>\n","protected":false},"author":2,"featured_media":94027,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[786],"tags":[2782],"industries-application":[2177,2180,2187,2185,2191,2193,2189,2190],"post-badge":[29],"resource-type":[],"product-library":[2435,2410],"resource-technique":[2310],"ppma_author":[685],"class_list":["post-92941","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-zh","tag-pfas","industries-application-clinical-zh","industries-application-clinical-toxicology-zh","industries-application-drinking-water-wastewater-testing-zh","industries-application-environmental-zh","industries-application-food-beverage-zh","industries-application-food-safety-zh","industries-application-pfas-testing-zh","industries-application-soil-sediment-biota-testing-zh","post-badge-new","product-library-liquid-reference-standards-zh","product-library-reference-standard-products-zh","resource-technique-liquid-chromatography-zh"],"acf":[],"taxonomy_info":{"category":[{"value":786,"label":"\u6587\u7ae0"}],"post_tag":[{"value":2782,"label":"PFAS"}],"industries-application":[{"value":2177,"label":"\u4e34\u5e8a"},{"value":2180,"label":"\u4e34\u5e8a\u6bd2\u7406\u5b66"},{"value":2187,"label":"\u996e\u7528\u6c34&amp;\u5e9f\u6c34\u68c0\u6d4b"},{"value":2185,"label":"\u73af\u5883"},{"value":2191,"label":"\u98df\u54c1\u548c\u996e\u6599"},{"value":2193,"label":"\u98df\u54c1\u5b89\u5168"},{"value":2189,"label":"PFAS\u68c0\u6d4b"},{"value":2190,"label":"\u571f\u58e4\u3001\u6c89\u79ef\u7269\u3001\u751f\u7269\u68c0\u6d4b"}],"post-badge":[{"value":29,"label":"New"}],"product-library":[{"value":2435,"label":"\u6db2\u4f53\u53c2\u8003\u6807\u51c6\u54c1"},{"value":2410,"label":"\u53c2\u8003\u6807\u51c6\u54c1"}],"resource-technique":[{"value":2310,"label":"\u6db2\u76f8\u8272\u8c31"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-gnar5636-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/zh-hans\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":786,"name":"\u6587\u7ae0","slug":"articles-zh","term_group":0,"term_taxonomy_id":786,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":786,"category_count":511,"category_description":"","cat_name":"\u6587\u7ae0","category_nicename":"articles-zh","category_parent":0}],"tag_info":[{"term_id":2782,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2782,"taxonomy":"post_tag","description":"","parent":0,"count":124,"filter":"raw"}],"authors":[{"term_id":685,"user_id":0,"is_guest":1,"slug":"grayson-ritch","display_name":"Grayson Ritch","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-ritch-grayson.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-ritch-grayson.jpg"},"author_category":"1","first_name":"Grayson","last_name":"Ritch","user_url":"https:\/\/www.linkedin.com\/in\/grayson-ritch-66426923b\/","job_title":"Senior Scientist, Reference Standards, R&D","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/92941","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=92941"}],"version-history":[{"count":35,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/92941\/revisions"}],"predecessor-version":[{"id":100278,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/posts\/92941\/revisions\/100278"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media\/94027"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=92941"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/categories?post=92941"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/tags?post=92941"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/industries-application?post=92941"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/post-badge?post=92941"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-type?post=92941"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/product-library?post=92941"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/resource-technique?post=92941"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/zh-hans\/wp-json\/wp\/v2\/ppma_author?post=92941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}