Artikel

PFAS Analysis by ISO 23702-1:2023 for Leather

03 Oct 2025

feature GNAR4301
  • Sample Matrix: leather
  • Sample Preparation: methanol extraction
  • Detection Technique: LC-MS/MS

Determination of the nonvolatile compound content by extraction method using liquid chromatography/ tandem mass spectrometry detector (LC-MS/MS)

ISO 23702-1:2023 is used for the analysis of 42 PFAS in leather. It is not available from Restek but may be purchased from other sources. The full analyte list and recommended products for ISO 23702-1:2023 are provided below. In addition, you can register and directly compare analyte lists and matrices across PFAS analysis methods here or visit www.restek.com/PFAS to explore our technical resources for PFAS analysis.

Analyte List for ISO 23702-1:2023 for PFAS Analysis

PFAS acronyms, compound names, and CAS numbers vary across methods and guidelines, and they also depend on compound form (e.g., neutral vs. salt). The following list uses standardized terminology to allow easy comparison across the methods and guidelines in our comprehensive guide. Please refer to ISO 23702-1:2023 for method-specific nomenclature.

AcronymPFAS NameCAS
PFBSPerfluoro-1-butanesulfonic acid375-73-5
PFDAPerfluorodecanoic acid335-76-2
PFDoAPerfluorododecanoic acid307-55-1
PFHpA*Perfluoroheptanoic acid375-85-9
PFHxSPerfluoro-1-hexanesulfonic acid355-46-4
PFHxAPerfluorohexanoic acid307-24-4
PFNAPerfluorononanoic acid375-95-1
PFOSPerfluorooctanesulfonic acid1763-23-1
PFOSFHeptadecafluorooctanesulfonyl fluoride307-35-7
PFOAPerfluorooctanoic acid335-67-1
Me-PFOAMethyl perfluorooctanoate376-27-2
Et-PFOAEthyl perfluorooctanoate3108-24-5
PF-3,7-DMOAPerfluoro(3,7-dimethyloctanoic acid)172155-07-6
PFTeDAPerfluorotetradecanoic acid376-06-7
PFTrDAPerfluorotridecanoic acid72629-94-8
PFUnAPerfluoroundecanoic acid2058-94-8
HFPO-DA, GenXHexafluoropropylene oxide dimer acid13252-13-6
PFBA*Perfluorobutanoic acid375-22-4
PFPeA*Perfluoropentanoic acid2706-90-3
PFDS*Perfluoro-1-decanesulfonic acid335-77-3
PFHpS*Perfluoro-1-heptanesulfonic acid375-92-8
FOSAPerfluoro-1-octanesulfonamide754-91-6
4:2 FTS*1H,1H,2H,2H-Perfluorohexane sulfonic acid757124-72-4
6:2 FTS*1H,1H,2H,2H-Perfluorooctane sulfonic acid27619-97-2
8:2 FTS1H,1H,2H,2H-Perfluorodecane sulfonic acid39108-34-4
10:2 FTS*1H,1H,2H,2H-perfluorododecane sulfonate (10:2)120226-60-0
NMeFOSAN-Methylperfluorooctanesulfonamide31506-32-8
NEtFOSAN-Ethylperfluorooctanesulfonamide4151-50-2
NMeFOSE2-(N-methylperfluoro-1-octanesulfonamido)-ethanol24448-09-7
NEtFOSE2-(N-ethylperfluoro-1-octanesulfonamido)-ethanol1691-99-2
8:3 FTCA2H,2H,3H,3H-Heptadecafluoroundecanoic acid34598-33-9
10:2 FTOH1H,1H,2H,2H-Perfluorododecan-1-ol or 2-(Perfluorodecyl)ethanol865-86-1
8:2 FTOH1H,1H,2H,2H-Perfluoro-1-decanol678-39-7
6:2 FTOH*3,3,4,4,5,5,6,6,7,7,8,8,8-Tridecafluorooctan-1-ol or 3,3,4,4,5,5,6,6,7,7,8,8,8-Tridecafluoro-1-octanol647-42-7
4:2 FTOH*1H,1H,2H,2H-Perfluorohexan-1-ol or 1-Hexanol2043-47-2
6:2 FTA*1H,1H,2H,2H-Perfluorooctyl acrylate17527-29-6
8:2 FTA1H,1H,2H,2H-Perfluorodecyl acrylate27905-45-9
10:2 FTA1H,1H,2H,2H-Perfluorododecyl acrylate17741-60-5
6:2 FTMA*1H,1H,2H,2H-heptadecafluorooctylmethacrylate2144-53-8
8:2 FTMA1H,1H,2H,2H-heptadecafluorodecylmethacrylate1996-88-9
7HPFHpA*7H-Dodecafluoroheptanoic acid1546-95-8
1-Decanaminium, N-decyl-N, N dimethyl-0,1,1,2,2,3,3,4,4,5,5,6,6,7,7,8,8,8-heptadecafluoro-1-octanesulfonate251099-16-8

*Optional compound

Recommended Products for ISO 23702-1:2023 for PFAS Analysis

Analytical LC Columns:


Raptor C18, 2.7 µm, 50×2.1 mm HPLC-Säule
Force C18, 1.8 µm, 50 x 2.1mm LC-Säule

Delay Columns:


PFAS Delay-Säule, 5 µm, 50×2.1 mm HPLC-Säule

PFAS delay column: 5 µm, 50 x 3.0 mm (cat.# 580959 [custom product])

Guard Columns:


UltraShield UHPLC Vorsäulen-Filter, 0.2 μm Fritte, 1
EXP Direct Connect-Halter für EXP Vorsäulenkartuschen, enthält Fittings und Ferrules
Raptor C18 EXP Vorsäulenkartusche, 2.7 µm, 5 x 2.1 mm, 3er Pack

Sample Prep:


25 mm Spritzenfilter, 0.22 µm, Polypropylen, blau, Luer-Lock, 100er Pack
Q-sep Multispeed-Zentrifuge für QuEChERS

Vacuum Manifolds:


Resprep QR-24 Vakuum-Absaugstation
Resprep QR-12 Vakuum-Absaugstation

Vacuum Pumps:


Chemker 300 PTFE Vakuumpumpe, 20 L/min, AC 110 V, 60 Hz
Chemker 300 PTFE Vakuumpumpe, 18 L/min, AC 220 V, 50 Hz

General Lab Supplies:


Screw-Thread Polypropylen Vials mit begrenztem Volumen, 9 mm, 700 μL, 12 x 32 mm, 100er Pack
Screw-Thread Polypropylen Vials mit begrenztem Volumen, 9 mm, 700 μL, 12 x 32 mm, 1000er Pack
2.0 mL, 9 mm Solid Top-Polyethylen Kappen, Screw-Thread, 10 mil dicke Membran, farblos, 100er Pack
2.0 mL, 9 mm Solid Top-Polyethylen Kappen, Screw-Thread, 10 mil dicke Membran, farblos, 1000er Pack
Leere Zentrifugenröhrchen, 50 mL, Polypropylen mit Kappe, 50er Pck.
Leere Zentrifugenröhrchen, 50 mL, Polypropylen mit Kappe, 500er Pck.
Norm-Ject Kunststoffspritze, 10 mL Luer-Lock-Spitze, 100er Pck.
Norm-Ject Kunststoffspritze, 5 mL Luer-Lock-Spitze, 100er Pck.

Discover More Solutions for PFAS Analysis!

Start Saving
Time Today

Develop PFAS Methods in Minutes with our Pro EZLC Chromatogram Modeler

Start Saving Time Today

Develop PFAS Methods in Minutes with our Pro EZLC Chromatogram Modeler

Author

  • Restek Corporation

    Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions.

    View all posts
GNAR4301
Version: A