Tipps zur Herstellung von Standards für Kalibrierkurven und zur Vermeidung von Fehlerquellen

Tipps zur Herstellung von Standards für Kalibrierkurven und zur Vermeidung von Fehlerquellen

Bei der Erstellung von Kalibrierkurvenstandards ist die Minimierung von Fehlerquellen entscheidend für die Erzielung genauer quantitativer Ergebnisse. In diesem Artikel werden bewährte Verfahren in Bezug auf Geräte, chemische Wechselwirkungen und Workflow-Lösungen vorgestellt, die dazu beitragen, genaue und präzise Analyseergebnisse zu gewährleisten.

Analytical Method for Polycyclic Aromatic Hydrocarbons (PAHs) in Yerba Mate Tea Using Modified QuEChERS, Solid Phase Extraction and GC-TOFMS and GC-MS/MS

Analytical Method for Polycyclic Aromatic Hydrocarbons (PAHs) in Yerba Mate Tea Using Modified QuEChERS, Solid Phase Extraction and GC-TOFMS and GC-MS/MS

This application note describes the development of an analytical method for PAHs in tea that allows analysts to more quickly and accurately characterize target PAHs. Sample preparation is based on a modified QuEChERS extraction and solid phase extraction sample cleanup. Both GC-TOFMS and GC-MS/MS techniques were used and analyses were optimized for resolution of isobaric compounds, as well as for maintaining a reasonable analysis time.

Evaluation of Dispersive and Cartridge Solid Phase Extraction (SPE) Cleanups for Multiresidue Pesticides in QuEChERS Extracts of Finished Tobacco Using GCxGC-TOFMS

We compared the efficacy of dSPE and cSPE cleanup methods for multiresidue pesticide analysis of QuEChERS extracts of finished tobacco products using GCxGC-TOFMS. Cleanup with dSPE tubes containing 7.5 mg of GCB and 25 mg of PSA produced better results than other methods, with average recoveries of 92% and 91% for 500 ppb and 50 ppb fortifications respectively.

Comparing Pesticide Residues in Amish and Commercially Grown Strawberries and Spinach Using QuEChERS, Various dSPE Sorbents, and GC-TOFMS

QuEChERS extraction, dSPE cleanup, and GC-TOFMS analysis were used to assess pesticide residue levels in strawberry and spinach from both commercial and Amish growers. Various dSPE sorbent products were compared to determine which were most effective.

High-Quality Analysis of Pesticides in Cannabis Using QuEChERS, Cartridge SPE Cleanup, and GCxGC-TOFMS

As medical marijuana is more frequently prescribed, patient safety must be ensured. Pesticide residue testing is an important part of assuring safe product is dispensed, but analysis can be extremely challenging due to matrix complexity. The use of QuEChERS, cartridge SPE cleanup, and GCxGC-TOFMS as presented here, produces high-quality quantitative data for this difficult analysis.

Fast, Simple Sample Cleanup

Quick, Easy, Cheap, Effective, Rugged, and Safe, the QuEChERS (catchers) method for extracting pesticides from food is based on USDA research and employs a novel dispersive solid phase extraction cleanup (dSPE). QuEChERS methods are convenient, rugged methods that simplify extract cleanup, reduce material costs, and improve sample throughput. Here we demonstrate the effectiveness of QuEChERS sample cleanup using a multiresidue analysis of pesticides on strawberries.

Robust 9-Minute GC Analysis of Cholesterol

Conditions are established for analyzing both derivatized and underivatized cholesterol on a highly inert Rxi-5ms column. Methods described include both an isothermal analysis for use when interferences are minimal, but sample throughput is critical, and a temperature program for use when separation of analytes from contaminants or interfering compounds is the primary concern. Results for both derivatized and underivatized samples were highly reproducible.