Restek offers a complete line of ASE extraction products. Below are our most frequently requested parts with Dionex/Thermo cross-reference information for fast and convenient selection.
Note: We guarantee the compatibility of Restek and Dionex/Thermo ASE parts only between entirely assembled caps and bodies. For example, if a Restek cap is assembled using all Restek parts, then it is compatible with a Dionex/Thermo body. However, if a Restek cap has a Dionex/Thermo insert (or vice versa), we cannot guarantee compatibility.
Cell Bodies
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | ||||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | |
| 1 mL | — | — | 25993 | 068261 | — | 054973 | — | — | 25993 | 068261 |
| 5 mL | — | — | 25994 | 068262 | 26112 | 054974 | — | — | 25994 | 068262 |
| 10 mL | — | — | 25995 | 068263 | — | — | — | — | 25995 | 068263 |
| 11 mL | — | — | — | — | 26114 | 048820 | — | — | — | — |
| 22 mL | — | — | 25996 | 068264 | 26098 | 048821 | — | — | 25996 | 068264 |
| 33 mL | — | — | — | — | 26116 | 048822 | — | — | — | — |
| 34 mL | 26176 | 056646 | 26176 | 056646 | — | — | 26176 | 056646 | 26176 | 056646 |
| 66 mL | 26178 | 056696 | 26178 | 056696 | — | — | 26178 | 056696 | 26178 | 056696 |
| 100 mL | 26132 | 056693 | 26132 | 056693 | — | — | 26132 | 056693 | 26132 | 056693 |
Cell Caps
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | |||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# |
| — | 056921 | 25997 | 068106 (SS) | 26096 | 049450 | — | 056921 | 25997 | 068106 (SS) |
| — | — | — | 068107 (Zirconium) | — | — | — | — | — | 068107 (Zirconium) |
Frits
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | |||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# |
| 26174 (SS, 6 pk) | 056775 (SS, 50 pk) | 26174 (SS, 6 pk) | 056775 (SS, 50 pk) | 26100 (10 pk) 25959 (100 pk) | 049453 (SS, 50 pk) | 26174 (SS, 6 pk) | 056775 (SS, 50 pk) | 26174 (SS, 6 pk) | 056775 (SS, 50 pk) |
| — | — | — | 068260 (Zirconium, 50 pk) | — | — | — | — | — | 068260 (Zirconium, 50 pk) |
Snap Ring
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | |||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# |
| 26134 (12 pk) | 056778 (10 pk) | 26134 (12 pk) | 056778 (10 pk) | 26184 (12 pk) | 049456 | 26134 (12 pk) | 056778 (10 pk) | 26134 (12 pk) | 056778 (10 pk) |
O-Rings
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | |||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# |
| 26187 (PTFE, 100 pk) | 049457 (PTFE, 50 pk) | 26187 (PTFE, 100 pk) | 049457 (PTFE, 50 pk) | 26187 (PTFE, 100 pk) | 049457 (PTFE, 50 pk) | 26187 (PTFE, 100 pk) | 049457 (PTFE, 50 pk) | 26187 (PTFE, 100 pk) | 049457 (PTFE, 50 pk) |
| 26188 (Viton, 50 pk) | 056325 (Viton, 50 pk) | 26188 (Viton, 50 pk) | 056325 (Viton, 50 pk) | 26188 (Viton, 50 pk) | 056325 (Viton, 50 pk) | 26188 (Viton, 50 pk) | 056325 (Viton, 50 pk) | 26188 (Viton, 50 pk) | 056325 (Viton, 50 pk) |
PEEK Seals
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | |||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# |
| 25393 (12 pk) 25394 (48 pk) | 061687 (50 pk) 056776 (50 pk) 56777 (10 pk) | 25393 (12 pk) 25394 (48 pk) | 061687 (50 pk) | 25256 (12 pk) 25257 (48 pk) 26120 (250 pk) | 049454 (50 pk) | 25393 (12 pk) 25394 (48 pk) | 061687 (50 pk) 056776 (50 pk) 56777 (10 pk) | 25393 (12 pk) 25394 (48 pk) | 061687 (50 pk) |
Funnel
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | |||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# |
| 26169 | 056699 | 26169 | 056699 | — | 056958 | 26169 | 056699 | 26169 | 056699 |
Collection Vials/Bottles (Vials for ASE 200, bottles for other ASE models)
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | |||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# |
| 26191 (clear) | 056284 (clear) | 26191 (clear) | 056284 (clear) | 26121 (clear) | 048784 (clear) | 26191 (clear) | 056284 (clear) | 26191 (clear) | 056284 (clear) |
| 26260 (amber) | — | — | — | 26122 (amber) | 048781 (amber) | 26260 (amber) | — | 26260 (amber) | — |
Filters
| ASE 100 | ASE 150 | ASE 200 | ASE 300 | ASE 350 | |||||
| Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# | Restek cat.# | Dionex/Thermo cat.# |
| 26168 | 056780 | 26168 | 056780 | 26118 (100 pk) | 049458 | 26168 | 056780 | 26168 | 056780 |
| 26189 | 056781 | 26189 | 056781 | 26190 (1000 pk) | 26189 | 056781 | 26189 | 056781 | |
| — | — | — | — | 26119 | 047017 | — | — | — | — |

