GC Analysis of Total Reduced Sulfurs at ppbv Levels

Ultra-low bleed and exceptional inertness assure complete separation of sulfur compounds (hydrogen sulfide, carbonyl sulfide, dimethyl sulfide, mercaptans) on our new column, with excellent peak shapes and reliable quantification at ppbv levels. A Sulfinert treated sampling/transfer system assures no adsorption losses of these very reactive compounds.

Analysis of Biodiesel Fatty Acid Methyl Esters (FAME) in Aviation Jet Fuels Using Method IP 585

Analysis of Biodiesel Fatty Acid Methyl Esters (FAME) in Aviation Jet Fuels Using Method IP 585

Accurate analysis of biodiesel FAME in jet fuel is critical for ensuring that contamination levels do not exceed allowable limits. Method IP 585 is commonly used for this analysis and here we perform the method using a Stabilwax column and GC-MS in SIM mode. Method calibration curve criteria were met and good recoveries of the total FAME content in jet fuel were obtained.

Analysis of FAMEs in Biodiesel Fuel: Pro EZGC Modeling Software Ensures Proper Column Selection

Analysis of FAMEs in Biodiesel Fuel: Pro EZGC Modeling Software Ensures Proper Column Selection

Polar columns were evaluated for the analysis of fatty acids methyl esters (FAMEs) in finished B100 biodiesel according to method EN 14103 (2011). Using Restek’s Pro EZGC chromatogram modeler, a high cyano phase Rt-2330 column and a polyethylene glycol phase FAMEWAX column were compared. The modeling software predicted an unacceptable coelution between the internal standard (C19:0 FAME) and FAME C18:2 when using the Rt-2330 column. However, the modeler also predicted that the FAMEWAX column would separate all the compounds of interest, which was demonstrated empirically. In addition, the results on the FAMEWAX column showed excellent repeatability for both total FAMEs and the linolenic acid methyl ester component.

Using Alternative Carrier Gases with Accelerated ASTM D2887 Simulated Distillation Analysis

Using Alternative Carrier Gases with Accelerated ASTM D2887 Simulated Distillation Analysis

ASTM Method D2887 now allows for alternate carrier gases, so hydrogen or nitrogen can replace helium carrier gas for simulated distillation. Here, we show that with an MXT-1HT SimDist column and Restek’s EZGC online method translator existing methods using helium can be easily converted to either hydrogen or nitrogen carrier gas. Because retention times are preserved with proper method translation, there are minimal changes to peak identification tables which significantly simplifies method validation.

Protect Natural Gas Sample Integrity and Prevent Sulfur Loss with Sulfinert Sample Cylinders

Sulfur compounds in fuel streams can damage equipment and reduce BTU values. Sulfinert sample cylinders are significantly more inert than stainless steel cylinders and assure sample integrity during collection, transportation, and storage.

Assaying Local Anesthetics by GC/FID

An Rxi-5ms column and a wool-packed inlet liner provide the stability and inertness needed for these basic, active analytes. Chromatography from a six-replicate system suitability analysis was well within normal acceptance criteria. USP tailing factors were approximately 1.00 for all analytes; retention times and area responses were very stable.

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Carrier gas changes for SimDist methods, such as ASTM Method D7213, can be easily implemented in your daily process. Using MXT-1HT SimDist columns and EZGC method translation software, helium-based SimDist methods can be easily translated to alternative carrier gases while maintaining ASTM Method D7213 requirements.

Two Options for Analyzing Potential Genotoxic Impurities in Active Pharmaceutical Ingredients

Two options for the analysis of PGIs in API have been developed by Merck and Restek to meet different laboratory needs. The first option is a fast method for the analysis of sulfonate esters on the Rxi-5Sil MS column. The second option is a comprehensive method for the analysis of both sulfonate esters and alkyl halides on the Rtx-200 column. Both methods require very little sample preparation, which helps increase laboratory productivity.