活动

Euroanalysis

11 Nov 2025

Euroanalysis

header landing page ASMS 2025 01b
header GNOT4524 NEMC 2025 EPA Analysis 02
header landing page Euroanalysis 2025 01
HPLC Banner Biphenyl
header landing page ASMS 2025 02b

Since 1985 our expert chromatography team has been offering smart solutions to help analysts around the globe make the world safer and healthier. 

We’re committed to providing exceptional customer service and offer a comprehensive range of technical and educational resources to support your analysis. Visit us at booth 14 at Euroanalysis and SECyTA 2025 and discover more about: 

  • EZ Suite – Optimize your methods online for free and in real time. Fine-tune or adjust your GC and LC methods in just minutes from your desk. Our online tools and calculators are easy to use, reliable, and help you develop methods without trial and error. 
  • 20 Years of Biphenyl: A Bold Innovation That Lasts. Two decades ago, we changed the game with Biphenyl—and it continues to redefine selectivity in LC. Join us to celebrate its 20th anniversary and learn more about this versatile LC column.  
  • PFAS Challenges? We Can Help. PFAS regulations and methods are evolving worldwide, but laboratories everywhere need fast, accurate, and dependable solutions. Restek offers high-quality products, personalised support, and expert technical advice to help you tackle even the toughest analyses. 
  • Looking to Save Helium? Discover our LPGC systems and reduce helium consumption by up to 3.3 times.

We look forward to welcoming you at Euroanalysis and SECyTA 2025! 

Solutions

Learn from Restek’s experts with this curated selection of articles, blog posts, and more. Want to learn more? Access our full resource hub.

Multi-Mycotoxin Method for Alternaria Toxins, Ergot Alkaloid Epimers, and Other Major Mycotoxins in Food?

Labs analyzing mycotoxins in food can increase productivity with this method for simultaneous quantitative analysis of 37 regulated and emerging mycotoxins–including Alternaria toxins, ergot alkaloid epimers, and other priority mycotoxins. Read Now→

Expanding Capabilities in Multi-Residue Pesticide Analysis Using the LCMS-8060

AUsing the Shimadzu Pesticide MRM Library and the Restek Raptor Biphenyl LC column, a single multiresidue LC-MS/MS method was developed for 646 pesticides. Read Now→

Accurately Analyze Metal-Sensitive Compounds with Restek’s New Inert LC Columns and Guards

Our extended offering of Inert LC columns and guards helps labs improve their analysis of metal-sensitive compounds. A premium inert coating reduces nonspecific binding of chelating analytes, enabling sensitive analysis and smooth integration of peaks. Read Now→

Quick-Start Guide to LPGC

In this guide, learn whether your analysis is amenable to LPGC and how to install and optimize your new LPGC kit! Read Now→

An Introduction to Low-Pressure GC-MS (LPGC-MS)

LPGC-MS provides significant speed gains compared to conventional methods, but historically it has been difficult to implement. Learn how a pre-assembled low-pressure column kit simplifies setup and makes the benefits of this advanced technique widely attainable. Read Now→

Revive In-Line Sample Preparation (ILSP): A Faster Approach for Multiresidue Pesticides in Food

Revive in-line sample preparation combines an automated sample cleanup with concurrent analysis, significantly speeding up LC-MS/MS multiresidue pesticide analysis in food. Read Now→

Improve Semivolatiles Method Performance with Rxi-SVOCms Columns

Designed specifically for semivolatiles methods, highly inert Rxi-SVOCms columns consistently produce good peak shapes and responses, even for difficult compounds. Improved chromatography means calibrations last longer and sample throughput can be increased. Read Now→

Videos

Your Partner in PFAS Analysis

Rely on Restek’s experience as a global leader in PFAS analysis. From app notes and webinars to advanced sample prep and analytical techniques, leverage our expertise in PFAS for your analysis. Watch Now→

Pro EZLC Software Simplifies LC Method Development

LC method development typically involves a lot of trial and error. It occupies precious lab resources and can take a considerable amount of time. Our Pro EZLC chromatogram modeler dramatically speeds up LC method development. Add analytes, test column chemistries, and optimize run conditions virtually and instantly—without needing to make a single injection. And it’s completely free to use. Watch Now→

Pro EZGC Chromatogram Modeler — Introduction

Our popular Pro EZGC chromatogram modeler (also known as our chromatogram simulator) for polymer capillary columns is simple to use, but offers advanced options that give you more control over your GC method development. Watch Now→

Liquid Chromatography

Biphenyl Columns→
Adept at separating compounds that are hard to resolve or elute early on C18s, Biphenyl columns are extremely useful for bioanalytical testing applications, like drug and metabolite analyses.

Inert Columns→
Featuring a premium inert coating applied to its stainless-steel surface, these columns are ideal for the analysis of metal-sensitive compounds.

Pro EZLC Chromatogram Modeler→
Develop and optimize LC methods in minutes with this free and powerful software.

Restek LC column.

Gas Chromatography

Capillary Columns→
Outstanding inertness, low bleed, and high reproducibility to ensure accurate data and maximum instrument uptime. 

LPGC→
Leverage your MS vacuum to significantly speed up analyses

Inlet Supplies→
Easy to use and long-lasting, these products provide guaranteed quality and consistency.

Pro EZGC Chromatogram Modeler→
Develop and optimize GC methods in minutes with this free and powerful software.

Restek fused silica GC column.

Reference Standards

PFAS Singles→

Pesticides→

Explosives→

Custom→

Restek reference standard ampul.

Presentations

Posters

Methodologies for Ultrashort-Chain and Comprehensive PFAS Analysis in Water Samples

Presenter(s)/Co-Author(s): Fernando Rodriguez Carrero, Emanuele Ceccon, Shun-Hsin Liang, Justin Steimling
Download Now

View Details

Per- and Polyfluoroalkyl substances(PFAS) have been a trending global issue for a number of years now. As more research is being carried out on these compounds, their breakdown paths, and their bioavailability, additional methods are required to quantify at lower concentrations, and to look for novel chemistries. As this search has expanded, shorter chain, and particularly ultrashort chain (USC) PFAS with carbon backbone lengths shorter than C4 have become areas of focus. In the most recent EU Commission Notice for Drinking Water (C/2024/4910) the fact TFA was not included in their definition of “PFAS Total” is highlighted as potential cause for concern, and both TFA and USC PFAS more generally are highlighted as areas for more specific monitoring. In this poster we examine two separate approaches to examining USC PFAS compounds. The first is a comprehensive look at a panel of PFAS compounds (C1-C14) with a dilute and shoot method using an inert coated, polar embedded alkyl LC column. The second is a more targeted screen via direct injection, focused upon USC PFAS utilising a novel HILIC/ion exchange LC column. These methods were then confirmed utilising a variety of fortified potable and non-potable water samples (industrial effluents, along with bottled, tap and spring waters). Both workflows demonstrate accuracy, sensitivity and linear calibration ranges of ppt levels, within industrially acceptable recovery values (70-130%). By integrating innovative tools and versatile columns, laboratories can streamline operations, save resources, and support sustainability—all without compromising analytical quality.

 

Towards Greener Workflows with Clever Method Development

Presenter(s)/Co-Author(s): Sandra Ruiz Perez, David Bell, Paul Connolly, Fernando Rodriguez Carrero
Download Now

View Details

Analytical labs face growing demands to reduce energy use, solvent waste, and costs without sacrificing performance. Traditional workflows often rely on time-consuming sample prep and multiple methods, increasing environmental impact and complexity. Our solution combines virtual method development tools and advanced chromatography phases to create greener, more efficient workflows. Tools like the Pro EZLC Chromatogram Modeler and Method Translator enable remote optimization and modernization of methods, cutting instrument time, solvent use, and energy consumption. Key to multi-method development is selecting the right stationary phase. While conventional C18 phases struggle with diverse analytes, Biphenyl phases offer enhanced selectivity through π–π and hydrophobic interactions, allowing consolidation of multiple analyses on a single column. This simplifies workflows, reduces material costs, and minimizes errors. By integrating innovative tools and versatile columns, laboratories can streamline operations, save resources, and support sustainability—all without compromising analytical quality.

 

↑
Back to Top

作者

  • Restek Corporation

    Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions.

    View Articles
GNOT4541
版本: A